REQUIREMENTS
I.Sces. all ow X01
Remove and safely dispose of all hazardous refuse and dry vegetation on the above premises (CFC
RETE/DRY
304.1.1)
DETAn-L
VION2
Provide non-combustible containers with tight fitting lids for the storage of combustible waste and
rubbish pending its safe disposal. (CFC 304.3.2) Note: applies to containers over 40 gallons.
to at least 3 feet clearance around motor fuse box/fire door (CFC
RENSTIBLE Imeade
3
Relocate combustible storage provide
604.3)
q
Relocate fire extoguisher(s) so that they will be in a conspicuous location, hanging on brackets with the
top to the extinguisher not more than 5 feet above the floor. (CFC 906.5 & 906.9)
rmeursxeRs
g
Provide and Install (amount) _ approved (type & size) portable fire
extinguisher to be immediately accessible for use In (area) ........
TABLE 906.3)
Re -charge all fire extinguishers. Fire extinguishers shall be serviced at least once each year, and/or
6
after each use, by a person having a valid license or certificate. (CFC 906.2)
Provide and maintain "EXIT" sigms) with letters 6 or more Inches In height over each required exit
..as
T
(door/window) to fire escape. (CFC 1013.6.1)
8
Provide and maintain appropriate numbers on a contrasting background and visible from the street to
Indicate the correct address of the building, (CFC 505.1)
9
Repair all (cracks/holes/openings) In plaster In (location) _ — ---- -------------- ------ --
FUSE
Plastering shall return the surface to Its original fire resistive condition. (CFC 703.1)
sOORSI xs
10
Remove/repair (Item & location) -__ — __ _ —-------- — --------- ----- ------
Self-closing doors shall be designed to close by gravity, or by the action of a mechanical device, or by an
approved smoke and heat sensitive device. Self-closing doors shall have no attachments capable of
preventing the operation of the closing device. (CFC 705.2.4)
1l
Remove all obstruction from hallways. Maintain all means of egress free of any storage. (CFC 1031.3)
Extra
12
Provide a contrasting colored and permanently Installed electric light over or near required exit
(location) _ ____ to clearly indicate It as an exit. (CFC 1008)
Remove all storage and/or other obstructions from fire escape landings and stairways stair shafts. (Fire
oRAOE
13
escapes/stair shafts are to be maintained free from obstructions at all times.) (CFC 1003.6)
Extension cords shall not be used in lieu of permanent approved wiring. Install additional approved
EnmuL APRLNNCES
TI
electrical outlets where needed. (CFC 604.5)
15
Remove multiple attachment cords from specific electrical convenience outlet (one plug per outlet) (CFC
604.4.2)
Commercial He"
16
Automatic Fire Extinp ins h in systems sh I be servl ad at least every 6 months FC 904.12. .2
17
Commercial cooking systems shall be operated and maintained in accordance with code (CFC 607)
TNE0.
l6
Violations of Section (CFC 5608.1) & 8.44.040 (B.M.C.).
RF I'•.r O , ave P, t14=
1
CORRECTION DATE
Correct the violations noted above by:
�N
'C"
CUSTOMER: /� \ k '
C-
C.F.C. CALIFORS AS COOE
OE
(Signature) (Please PFlOf Name L¢gibly�Title)
a. M.0BAITIONA ELD MUNICIPBLCODE
B.M.C.UKERSFIILBM MUNICIPAL
4dh^(5. '" NO.: 1'- 1
n.F.v.A. ASSOCIATIONE PRorecnox
INSPECTOR: /
H.E.C. NATIONAL ELECTRIC CODE
White - Prevention Services yellow - Station Copy Pink - Business Copy
r0 mzzluv. az/zazoi