HomeMy WebLinkAboutFire Safety 6-26-20_5-7FIRE PREVENTION INSPECTION or! -N BAKERSFIELD FIRE DEPARTMENT
�d Q Prevention Services
ri ♦�1 2101 H Street
Bakersfield, CA 93301
Phone: 661-326-3979 A Fax: 661-852-2171
FACUITY ADDRESSDATE
05 I
FACILITY NAM an, .—A, -A'
kZ:kW `- I N (ImL- 3-5
YSINE660WX1R'S NAME AND ADDRESS NAfe10E0.'S XYM! PH NO.
MAIL (IF DIFFERENT FROM ABOvq NAME, ADDREW CITY, ST>TE, An' PH NO.
PE
O�IA AO
O.i! LOOED R6ER DATE
�r
can/Dry spMngo- sTMA.
Typnor AMnnsyetem
CD ON TyIEIsaL..MD/FT OF BLD
❑ YES ❑NO
CONRECT ALL VIOLATIONS. W
RERYIREXENT6
Npt
Remove and safely dispose of all hazardous refuse and dry vegetation on the above premises (CFC
�iEcn4noxe wasre/Pav
304.1.1)
2
Provide non-combustible containers with tight fitting lids for the storage of combustible waste and
rubbish pending its safe disposal. (CFC 304.3.2) Note: applies to containers over 40 gallons.
MpusnmE StORAOE
3
Relocate combustible storage to provide at least 3 feet clearance around motor fuse box/fire door (CFC
604.3)
4
Relocate fire extinguisher(s) so that they will be in a conspicuous location, hanging on brackets with the
top to the extinguisher not more than 5 feet above the floor. (CFC 906.5 & 906.9)
ExcOSXERs
5
Provide and install (amount) _ _ approved (type & size) portable fire
extinguisher to be immediately accessible for use In (area) _ - — ___ -------------- (CFC
TABLE 906.3)
6
Re -charge all fire extinguishers. Fire extinguishers shall be serviced at least once each year, and/or
after each use, by a person having a valid license or certificate. (CFC 906.2)
/
Provide and maintain "EXIT' signs) with letters 6 or mare Inches in height over each required exit
MONS
(door/window) to fire escape. (CFC 1013.6.1)
8
Provide and maintain appropriate numbers on a contrasting background and visible from the street to
indicate the Correct address of the building. (CFC 505.1)
9
Repair all (cracks/holes/openings) in plaster in (location) -_ - - _______ ___—_— - _______
IN.: IN.SOO�6 Mn
Plastering shall return the surface to its original fireresistive condition. (CFC 703.1)
,IN!
to
Remove/repair (Item & location) --- _____ — -------- — _—------ — --- -
Self-closing doors shall be designed to close by gravity, or by the action of a mechanical device, or by an
approved smoke and heat sensitive device. Self-closing doors shall have no attachments capable of
preventing the operation Of the closing device. (CFC 705.2.4)
L1
Remove all obstruction from hallways. Maintain all means of egress free of any storage. (CFC 1031..3)
Cmc
12
Provide a contrasting colored and permanently installed electric light over near required exit
(location) ___—---- — _----- ex to clearly Indicate it as an exit (CFC 1008)
Remove all storage and/or other obstructions from fire escape landings and stairways stair shafts. (Fire
easDNAeE
13
escapes/stair shafts are to be maintained free from obstructions at all times.) (CFC 1003.6)
I4
Extension cords shall not be used In lieu of permanent approved wiring. Install additional approved
rnuCAL APPLIANCES
electrical outlets where needed. (CFC 604.5)
is
Remove multiple attachment cords from specific electrical convenience outlet (one plug per outlet) (CFC
604.4.2)
COmmlwldl HNAJ
16
Automatic Fire Extinguishino systems shall be serviced at least evgry 6 months CFC 904. 2.5.2
17
Commercial cooking systems shall be operated and maintained In accordance with code (CFC 607)
OTHER
is
Violations of Section (CFC 5608.1) & 8.44.040 (B.M.C.).
CORRECTION DAT
Correct the violations noted above by:
CUSTOMER: c 1V1 ' r _T t1l
C... CFLiFORNIA FIRE CODE
C.B.C. CALIFORNIA BUILDING CODE
[51g ure) (PlEaae Pri,rt Nam®. Legibly�TitleJ
B.M.C. BAKERSFIELD MUNICIPAL CODE
NO.: P -S
N.F.P.A. NATIONAL FIRE PROTECTION
INSPECTOR:
ASSOCN.C.
NATIO NAL ELECTRIC CODE
White - Prevention Services Yellow - Station Copy Pink - Business Copy
11 ian (R. WnI.)