HomeMy WebLinkAboutCUPA 6-10-2020Underground Storage Tank Program
DW Inspection Report
Permission to Inspect:
BAKERSFIELD FIRE DEPARTMENT
Prevention Services Division
2101 H Street
Bakersfield, CA 93301
Phone: 661-326-3979
Fax: 661-852-2171
Business Name: 7 -Eleven Inc #38530 15-021-114261
Date:6/10/2020 CAL000454837
Address Name: 1900 Union Ave Bakersfield, CA 93305
Inspector Name: Peter Armagost #8856813
Inspection Type: Routine
Report : Final
NVQ = No Violation Observed OUT = Out of Compliance NA = Not Applicable UD = Undetermined
Cos = Corrected On Site RPT = Repeat Violation
Violation
Program Requirement
.0
SOC
Comments
No
0,
D
a
0
a.
P0
.0:
Z"
=
0
W
0.-
>
File Review
Facility Tank Information
2030021
Facility has a valid Permit
Tank 1 -20000 -REG -DW
to Operate from the
Tank 2 -8000 -PRM -DW
CUPA - 23 CCR 16 2712(1);
�
�
�
R
R
None
Tank 3 -12000 -DSL -DW
HSC 6.7 25284
2010010
UST Operating Permit
Application for Facility
information and Tank
information�
❑
❑
❑
❑
❑
None
submitted/maintained - 23
CCR 16 2711; HSC 6.7
25286(a)
2010001
Current BOE number
submitted to the CUPA
None
and/or CERS -HSC 6.7
25286(c)
2030011
UST compliance
statement and/or
Designated Operator
None
current certification
submitted - 23 CCR 16
2715(a), 2715(b)
2030046
A complete and accurate
response plan has been
submitted, approved and
None
maintained - 23 CCR 16
2632, 2634(e), 2641(h),
2712(i)
2030041
A complete and accurate
plot plan has been
submitted, approved and
�
❑
❑
❑
❑
❑
Minor
maintained - 23 CCR 16
2632(d)(1)(C)y 2711(a)(8)
2010006
Owner/Operator has not
made false statements or
representation on any
None
required document -HSC
6.725299
Violation
Program Requirement
a°, o
SOC
Comments
No
p
=
a
o
o
a
00
Z
o
z
o>
2010003
Owner/Operator has a
DO and/or informed the
CUPA of any change (s)
�
�
�
�
�
�
None
within 30 days - 23 CCR
16 2715(a)
Testing
2030002
Owner/Operator has
tested and certified leak
�
�
�
�
�
�
None
detection equipment
annual) - 23 CCR 16 2638
2030048
Secondary containment
testing conducted every
36 months in accordance
�
❑
❑
❑
❑
❑
None
with requirements - 23
CCR 16 2637
2030055
Spill buckets have been
tested annually as
None
required -HSC 6.7 25284.2
2010009
Secondary containment
test results submitted to
the CUPA within 30 days
None
after the test - 23 CCR 16
2637(e)
2030064
CUPA was poperly
notified within the
prescribed number of
�
�
�
�
�
�
None
hours prior to testing - 23
CCR 16 26370, 2638(e),
2643(g), 2644.7 a 4
Install/Repair
2060009
Permits obtained to
install, replace, repair, or
�
�
�
�
�
�
None
modify part of the UST
system - 23 CCR 16 2772
UST System Observation
General Monitoring
2030003
Leak detection system
maintains continuous
RD
monitoring that activates
�
�
�
�
�
�
None
❑
an audible and visual
Yes
alarm - 23 CCR 16 2632,
2634, 2636, 2666
2030016
The annular space of the
tank, piping and sumps
RD
are continuously
monitored and activates
�
❑
❑
❑
❑
❑
None
❑
the alarm - 23 CCR 76
Yes
2631(g), 2632(c)(2)(A)&(8),
2633(c), 2636
2030017
Product piping outside the
UDC is fail-safe and shuts
down the pump or
❑
❑
None
restricts flow - 23 CCR 16
2636(0 (5)
Underground Storage Tank Program - DW Inspection Report v 2.0
Violation
Program Requirement
a°, o
SOC
Comments
No
�
�
Q
o
o
a
�+o
Z
O
Z
n
U
W
� j
2030018
Turbine sump monitor
activates an audible and
RD
visual alarm or stops the
❑
❑
❑
❑
None
❑
flow of at the dispenser -
Yes
23 CCR 16 2636(0(1)
2030019
Monitoring system in the
UDCs activates an
audible and visual alarm
�
�
�
R
F]
R
None
or stops the flow at the
UDC -23 CCR 16
2636 (0(1)
2030043
Leak detection equipment
RD
properly programmed or
properly operated - 23
N
El
❑
El
❑
❑
None
❑
CCR 16 2632, 2634, 2636,
Yes
2666
2060005
System constructed with
a monitoring system
capable of detecting entry
�
�
R
RE]
R
None
into secondary
containment -HSC 6.7
25297 b
2060014
Correct leak detection
equipment installed for
RD
the type of system
�
�
�
�
�
�
None
❑
present - 23 CCR 16 2638;
Yes
HSC 6.7 25290.11 25290.21
25291
2060015
Sensor located in the
RD
proper position/location -
R
F]
R
R
R
None
❑
23 CCR 16 2630(d), 2649(a)
Yes
2030062
Facility is in compliance
RD
with not tampering with or
disabling leak detection
❑
❑
❑
El
❑
None
❑
devices or alarms -HSC
Yes
6.7 25299 a (9)
2060022
System constructed with
a monitoring system
capable of detecting entry
N
E:]
E]
F-1
F-�
R
None
into secondary
containment -HSC 6.7
25290.2(d)
2030034
Tag/sticker on affixed
monitoring equipment
being certified, repaired,
�
❑
❑
❑
❑
❑
None
or replaced - 23 CCR 16
2638
VPH Monitoring VPH
2030065
Interstitial monitoring of
RD
the annular spaces of the
UST is properly
F-1
F -1M
F]
F-1❑
None
F-1
maintained -HSC 6.7
Yes
25290.1 e
Underground Storage Tank Program - DW Inspection Report v 2.0
Violation
Program Requirement
� o
SOC
Comments
No
Cn
a)w
z
o
z
�
c0i
�
o f
2060023
System constructed with
a monitoring system
capable of detecting entry
into secondary
F-1❑
H
❑
❑
❑
None
containment -HSC 6.7
25290.1(d)
Line Leak
Detector
2060012
Line leak detector
installed on pressurized
RD
piping system -HSC 6.7
�
�
�
�
�
�
None
❑
25290.1(h), 25290.2(8),
Yes
25291(fl, 25292(e),
2636( (2)
2030026
Line leak detectors detect
a 3 gph leak and/or
RD
audible and visual alarm
El
F-1
0
F-1
M
F-1
None
❑
function properly - 23
Yes
CCR 16 2636(0(6),
2666(c)
2030027
Turbine shuts down when
a leak is detected or
RD
when line leak detector is
❑
❑
H
❑
❑
❑
None
El
disconnected - 23 CCR 76
Yes
2666(c)
2030025
Pressurized piping able to
detect a 3.0 gph leak
RD
within an hour, and
F-1
El
N
F]
1:1
F-1
None
[:1
restricts the flow or
Yes
alarms - 23 CCR 16
2636 0 2
Secondary Containment
2060010
UST storing a hazardous
RD
substance has secondary
H
R
EJ
F-]
F-]
M
None
❑
containment -HSC 6.7
Yes
25292
Underground Storage Tank Program - DW Inspection Report v 2.0
Violation
Program Requirement
o
�--
SOC
Comments
No
z
1
2 4 MIJ
p
z
�
v
�
o>
2030008
UDC, sumps, and/or
other secondary
containment in good
�
F-1
M
F-1
F-1
F-1
None
condition and/or are free
of debris/liquid -HSC 6.7
25290. 1, 25290.2, 25291
2030040
Secondarily contained
RD
piping maintained to allow
�
�
R
F]
F]
F-1
None
❑
liquid to drain into sump -
Yes
23 CCR 16 2630 d , 2641 a
2060006
Secondary containment
piping slopes back to the
�
R
F-�
F-1
F�
F-1
None
collection sump - 23 CCR
76 263(c)
2030047
Secondary containment
maintained tight and has
been confirmed by testing
�
F-�
F�
F-1
F�
F-1
None
- 23 CCR 16 2662; HSC 6.7
25290.1(c)12), 25290.2(c)(2),
25291 (a), 25292(e)
2030060
Entry fittings in secondary
containment for UST
system maintained
Z
F-1
R
El
M
F-1
None
tight/sealed - 23 CCR 16
2630, 2635(d), 2636(c),
2666
2060020
Spill bucket is installed
RP
and has a functional drain
valve or other means to
Z
❑
El
❑
❑
❑
None
❑
remove liquid - 23 CCR 16
Yes
2635(b), 2665
Underground Storage Tank Program - DW Inspection Report v 2.0
Violation.
Program Requirement
° o
SOC
Comments
No
L
tMLO
z
o
z
�
o
�
of
On Site Records
Certifications
2030023
Required designated
operators or contractors
maintain a proper and
�
❑
❑
❑
❑
❑
None
current ICC certification -
23 CCR 76 2715
2030024
Service technician,
installer, and/ or
employee maintain a
❑
❑
❑
❑
❑
None
proper license - 23 CCR
162715
2030031
Employee or contractor
obtained and maintained
proper manufacturer
None
certification - 23 CCR 16
2715
2010007
Submit/maintain current
Certificate of Financial
Responsibility/mechanism
of financial assurance -
�
�
�
�
�
�
None
23 CCR 16 2711; 23 CCR
18 2808.11 2809-2809.2;
HSC 6.7 25292.2; HSC
6.75 25299.30-25299.34
Designated Operator
2010004
Copies of DO inspections
for last 12 months and list
of trained employees
None
maintained - 23 CCR 16
2715
Underground Storage Tank Program - DW Inspection Report v 2•0
Violation
Program Requirement
° o
SOC
Comments
No
0
E
z
o z
�
c°�
�
o y
Logs
2030001
Leak detection alarm
logs, maintenance and
RD
records of appropriate
�
�
�
R
R
R
None
❑
follow-up actions
Yes
maintained - 23 CCR 96
2632, 2634, 2712(b)
Maintenance/Tests
2010008
Monitoring, maintenance,
repairs, linings, and
RD
upgrade records
�
�
�
�
�
�
None
❑
maintained for the proper
Yes
time period - 23 CCR 16
2712(b
Documentation
2030033
Failure to maintain on site
an approved monitoring
�
�
�
�
R
Fj
None
plan - 23 CCR 16 2632,
2634, 2711, 2712(i)
2030037
Written agreement
between the tank owner
and tank operator to
monitor the tank system
�
❑
❑
❑
❑
❑
None
is maintained - 23 CCR 16
2620(b); HSC 6.7
25284 a 3
2030061
Suspected or actual
unauthorized release
RD
reported in appropriate
❑
El
Z
F-1❑
❑
None
F-1
time frame -HSC 6.7
Yes
29294, 29295
General Operating Requirements
Permit Condition/Approval
2030039
Compliance with all
operating permit
�
�
R
F-]
None
conditions - 23 CCR 16
2712; HSC 6.7 25299
2030059
UST system maintained
in accordance with
exclusion/exemption
❑
❑
❑
None
status -HSC 6.7 25281.6,
25283.5
2030014
Owner/Operator received
approval and has
implemented a training
�
R
Z
R
R
R
None
program at an unstaffed
facility - 23 CCR 16
2715 (0(2)
2030015
Facility exhibited that the
method used to monitor
the tank meets the
monitoring methods in
❑
❑
❑
❑
❑
None
2643(f) - 23 CCR 16 2643
Underground Storage Tank Program - DW Inspection Report v 2.0
Violation
Program Requirement
4-
0 .2
SOC
Comments
No
0
>
<
0
0
CL
1;�
00
Z
0
z
W
j5 >
Red Tag
%J
2030045
Red Tag information is
legible and has not been
R
FJ
R
None
tampered with - 23 CCR
16 2717.7 (g)
2030044
Facility did not allow for
deposit of petroleum into
a UST that has a red tag
R
F]
Z
F]
None
affixed to the fill - 23 CCR
162717.1(0
Install/Repair
2060024
UST system is made of or
lined with materials that
are compatible with the
R
F1
1:1
R
None
substance stored - 23
CCR 16 2631.1
2060021
Striker plate installed and
positioned correctly - 23
Z
El
1:1
❑
El
F-1
None
CCR 16 2631(c),, 2662(d)
I
I
I
I I
® There were no violations noted for this inspection.
❑This report shall serve as a "NOTICE TO COMPLY" for Minor Violations, and a "NOTICE OF VIOLATION" for
Major violations. You are, hereby, ordered to correct the above noted violations within 30 days, or according to
correction summaries provided. Formal enforcement and/or penalty assessment may be initiated for any
violations noted, and for those not corrected in a timely manner. (NOTE: If this is a preliminary report, a final report
will follow.)
Inspectors Signature:
Date:
Inspector: Enter # of Violations: RD: RP:
Check one box for facility Significant Operational Status (SOC) to be reported to SWRCB and US EPA:
❑SOC with both Release Detection and Release Detection (Facility has no Release Prevention and no Release
Prevention Violations)
F-1 Not in SOC (Facility has both Release Prevention and Release Detection Violations)
❑SOC with Release Detection only (Facility has no Release Detection violations but one or more Release
Prevention violations)
M SOC with Release Prevention only (Facility has no Release Prevention violations but one or more Release
Detection violations)
Underground Storage Tank Program - DW Inspection Report v 2.0