Loading...
HomeMy WebLinkAboutSB989-Results 7-21-20&(56 &DOLIRUQLD(QYLURQPHQWDO5HSRUWLQJ6\VWHP,' ,GHQWLILFDWLRQ867 8QGHUJURXQG6WRUDJH7DQN,&& ,QWHUQDWLRQDO&RGH&RXQFLO1$ 1RW$SSOLFDEOH8'& 8QGHU 'LVSHQVHU&RQWDLQPHQW 81 ZZZXQLGRFVRUJ 5HY 81'(5*5281'6725$*(7$1. 6(&21'$5<&217$,10(177(67,1*5(3257)250 3DJHRI  7\SHRI$FWLRQ,QVWDOODWLRQ7HVW5HSDLU7HVW6L[0RQWK7HVW0RQWK7HVW , )$&,/,7<,1)250$7,21 &(56,''DWHRI6HFRQGDU\&RQWDLQPHQW7HVW %XVLQHVV1DPH(Same as Facility Name or DBA-Doing Business As) %XVLQHVV6LWH$GGUHVV &LW\ =,3&RGH ,, 81'(5*5281'6725$*(7$1.6(59,&(7(&+1,&,$1,1)250$7,21 1DPHRI8676HUYLFH7HFKQLFLDQ3HUIRUPLQJWKH7HVW(Print as shown on the ICC Certification) 3KRQH &RQWUDFWRU7DQN7HVWHU/LFHQVH ,&&&HUWLILFDWLRQ ,&&&HUWLILFDWLRQ([SLUDWLRQ'DWH ,,, 6800$5<2)6(&21'$5<&217$,10(177(67,1*5(68/76 7$1.,'(By tank number, stored product, etc.)$ % & ' 7DQN&RQWDLQPHQW 7LJKWQHVV7HVW5HVXOW3DVV)DLO1$3DVV)DLO1$3DVV)DLO1$3DVV)DLO1$ 3URGXFW3LSLQJ&RQWDLQPHQW 7LJKWQHVV7HVW5HVXOW3DVV)DLO1$3DVV)DLO1$3DVV)DLO1$3DVV)DLO1$ &RPPXQLFDWLRQ7HVW5HVXOW3DVV)DLO1$3DVV)DLO1$3DVV)DLO1$3DVV)DLO1$ 5HPRWH)LOO3LSLQJ&RQWDLQPHQW 7LJKWQHVV7HVW5HVXOW3DVV)DLO1$3DVV)DLO1$3DVV)DLO1$3DVV)DLO1$ &RPPXQLFDWLRQ7HVW5HVXOW3DVV)DLO1$3DVV)DLO1$3DVV)DLO1$3DVV)DLO1$ 9HQW3LSLQJ&RQWDLQPHQW 7LJKWQHVV7HVW5HVXOW3DVV)DLO1$3DVV)DLO1$3DVV)DLO1$3DVV)DLO1$ &RPPXQLFDWLRQ7HVW5HVXOW3DVV)DLO1$3DVV)DLO1$3DVV)DLO1$3DVV)DLO1$ 9DSRU5HFRYHU\3LSLQJ&RQWDLQPHQW 7LJKWQHVV7HVW5HVXOW3DVV)DLO1$3DVV)DLO1$3DVV)DLO1$3DVV)DLO1$ &RPPXQLFDWLRQ7HVW5HVXOW3DVV)DLO1$3DVV)DLO1$3DVV)DLO1$3DVV)DLO1$ 7XUELQH3URGXFW3LSLQJ6XPS 7LJKWQHVV7HVW5HVXOW3DVV)DLO1$3DVV)DLO1$3DVV)DLO1$3DVV)DLO1$ )LOO5LVHU6XPS 7LJKWQHVV7HVW5HVXOW3DVV)DLO1$3DVV)DLO1$3DVV)DLO1$3DVV)DLO1$ 9(1775$16,7,216803,'D E F G 7LJKWQHVV7HVW5HVXOW3DVV)DLO1$3DVV)DLO1$3DVV)DLO1$3DVV)DLO1$ 8'&,'    7LJKWQHVV7HVW5HVXOW3DVV)DLO1$3DVV)DLO1$3DVV)DLO1$3DVV)DLO1$ 8'&,'    7LJKWQHVV7HVW5HVXOW3DVV)DLO1$3DVV)DLO1$3DVV)DLO1$3DVV)DLO1$ 8'&,'    7LJKWQHVV7HVW5HVXOW3DVV)DLO1$3DVV)DLO1$3DVV)DLO1$3DVV)DLO1$ All items marked “Fail” or “NA” must be explained in their respective “COMMENTS” section. ,9 &(57,),&$7,21%<8676(59,&(7(&+1,&,$1&21'8&7,1*7+,67(67,1* ,KHUHE\FHUWLI\WKDWWKHVHFRQGDU\FRQWDLQPHQWZDVWHVWHGLQDFFRUGDQFHZLWK&DOLIRUQLD&RGHRI5HJXODWLRQV7LWOH'LYLVLRQ &KDSWHU6HFWLRQDQGDOOWKHLQIRUPDWLRQFRQWDLQHGKHUHLQLVDFFXUDWH 8676HUYLFH7HFKQLFLDQ6LJQDWXUH 10159161 7/21/2020 Fastrip #22 (North) 4013 South H Street Bakersfield 93304 Justin Williams (800) 339-9930 804904 8819073 9/8/2020 T1 87 12k gal T2 91 12k gal T3 diesel 12k gal 9-10 11-12 13-14 15-16 17-18 19-20 ,' ,GHQWLILFDWLRQ 81 ZZZXQLGRFVRUJ 5HY 81'(5*5281'6725$*(7$1. 6(&21'$5<&217$,10(177(67,1*5(3257)250 3DJHRI  9 7$1.6(&21'$5<&217$,10(17,1)250$7,21 0DQXIDFWXUHU,GHQWLI\7DQN,'IURP6HFWLRQ,,,IRUHDFK0DQXIDFWXUHU $%&' $%&' 7HVW0HWKRG8VHG0DQXIDFWXUHU*XLGHOLQHV(Specify) ,QGXVWU\&RGHRU(QJLQHHULQJ6WDQGDUG (Specify) (QJLQHHUHG0HWKRG(Specify) Attach the testing procedures and all documentation required to determine the results.RI$WWDFKHG3DJHV 7DQN&RQWDLQPHQW7HVWLQJ7UDLQLQJDQG&HUWLILFDWLRQV(List applicable certifications.) ([SLUDWLRQ'DWH 9, &200(176 Provide any additional comments here. 9,, 352'8&73,3,1*&217$,10(177(67,1*,1)250$7,21 0DQXIDFWXUHU,GHQWLI\7DQN,'IURP6HFWLRQ,,,IRUHDFK0DQXIDFWXUHU $%&' $%&' 7HVW0HWKRG8VHG0DQXIDFWXUHU*XLGHOLQHV(Specify) ,QGXVWU\&RGHRU(QJLQHHULQJ6WDQGDUG (Specify) (QJLQHHUHG0HWKRG(Specify) Attach the testing procedures and all documentation required to determine the results.RI$WWDFKHG3DJHV 3URGXFW3LSLQJ&RQWDLQPHQW7HVWLQJ7UDLQLQJDQG&HUWLILFDWLRQV(List applicable certifications.)([SLUDWLRQ'DWH ,QWHUVWLWLDO&RPPXQLFDWLRQ9HULILFDWLRQ0HWKRG8VHG 9,,, &200(176 Provide any additional comments here. Unknown PEI-1200 1 ICC Tech 8819073 9/8/2020 10/4/2020 Smith PEI-1200 1 ICC Tech 8819073 9/8/2020 Incon level 4 1027843710 10/4/2020 Check communication from furthest point. SWRCB, January 2002 97$1.6(&21'$5<&217$,10(17,1)250$7,21 Test Method Developed By: Tank Manufacturer Industry Standard Professional Engineer Other (Specify) Test Method Used: Pressure Vacuum Hydrostatic Other (Specify) Test Equipment Used: Equipment Resolution: Tank # Tank # Tank # Tank # Is Tank Exempt From Testing?1 Yes No Yes No Yes No Yes No Tank Capacity: Tank Material: Tank Manufacturer: Product Stored: Wait time between applying pressure/vacuum/water and starting test: Test Start Time: Initial Reading (RI): Test End Time: Final Reading (RF): Test Duration: Change in Reading (RF-RI): Pass/Fail Threshold or Criteria: Test Result: Pass Fail Pass Fail Pass Fail Pass Fail Was sensor removed for testing? Yes No NA Yes No NA Yes No NA Yes No NA Was sensor properly replaced and verified functional after testing? Yes No NA Yes No NA Yes No NA Yes No NA Comments – (include information on repairs made prior to testing, and recommended follow-up for failed tests) 1 Secondary containment systems where the continuous monitoring automatically monitors both the primary and secondary containment, such as systems that are hydrostatically monitored or under constant vacuum, are exempt from periodic containment testing. {California Code of Regulations, Title 23, Section 2637(a)(6)} ✔ ✔ Precision mechanical test gauge 0.0625” 87 91 Diesel ✔✔✔ 12k gallon 12k gallon 12k gallon Steel Steel Steel Unknown Unknown Unknown Gasoline Gasoline Diesel 30 minutes 30 minutes 30 minutes 9:00 am 10:00 am 9:00 am 10 hg 10 hg 10 hg 10:00 am 11:00 am 10:00 am 10 hg 10 hg 10 hg 60 minutes 60 minutes 60 minutes 0.00” 0.00” 0.00” 0.00” 0.00” 0.00” ✔✔✔ ✔ ✔✔ ✔ ✔✔ SWRCB, January 2002 9,,352'8&73,3,1*&217$,10(177(67,1*,1)250$7,21 Test Method Developed By: Piping Manufacturer Industry Standard Professional Engineer Other (Specify) Test Method Used: Pressure Vacuum Hydrostatic Other (Specify) Test Equipment Used: Equipment Resolution: Piping Run # Piping Run # Piping Run # Piping Run # Piping Material: Piping Manufacturer: Piping Diameter: Length of Piping Run: Product Stored: Method and location of piping-run isolation: Wait time between applying pressure/vacuum/water and starting test: Test Start Time: Initial Reading (RI): Test End Time: Final Reading (RF): Test Duration: Change in Reading (RF-RI): Pass/Fail Threshold or Criteria: Test Result: Pass Fail Pass Fail Pass Fail Pass Fail Comments – (include information on repairs made prior to testing, and recommended follow-up for failed tests) ✔ ✔ Precision mechanical test gauge 0.0625” 87 91 Diesel Fiberglass Fiberglass Fiberglass Smith Smith Smith 3.5”3.5”3.5” 175’175’175’ Gasoline Gasoline Diesel Boot in sump Boot in sump Boot in sump 30 minutes 30 minutes 30 minutes 9:00 am 9:00 am 10:30 am 5 psi 5 psi 5 psi 10:00 am 10:00 am 11:30 am 5 psi 5 psi 5 psi 60 minutes 60 minutes 60 minutes 0.00” 0.00”0.00” 0.00”0.00”0.00” ✔✔✔ ,' ,GHQWLILFDWLRQ 81 ZZZXQLGRFVRUJ 5HY 81'(5*5281'6725$*(7$1. 6(&21'$5<&217$,10(177(67,1*5(3257)250 3DJHRI  ;,,,9$3255(&29(5<3,3,1*&217$,10(177(67,1*,1)250$7,21 0DQXIDFWXUHU,GHQWLI\7DQN,'IURP6HFWLRQ,,,IRUHDFK0DQXIDFWXUHU $%&' $%&' 7HVW0HWKRG8VHG0DQXIDFWXUHU*XLGHOLQHV(Specify) ,QGXVWU\&RGHRU(QJLQHHULQJ6WDQGDUG (Specify) (QJLQHHUHG0HWKRG(Specify) Attach the testing procedures and all documentation required to determine the results.RI$WWDFKHG3DJHV 9DSRU5HFRYHU\3LSLQJ&RQWDLQPHQW7HVWLQJ7UDLQLQJDQG&HUWLILFDWLRQV(List applicable certifications.)([SLUDWLRQ'DWH ,QWHUVWLWLDO&RPPXQLFDWLRQ9HULILFDWLRQ0HWKRG8VHG ;,9 &200(176 Provide any additional comments here. ;9 785%,1(352'8&73,3,1*68037(67,1*,1)250$7,21 0DQXIDFWXUHU,GHQWLI\7DQN,'IURP6HFWLRQ,,,IRUHDFK0DQXIDFWXUHU $%&' $%&' 7HVW0HWKRG8VHG0DQXIDFWXUHU*XLGHOLQHV(Specify) ,QGXVWU\&RGHRU(QJLQHHULQJ6WDQGDUG (Specify) (QJLQHHUHG0HWKRG(Specify) Attach the testing procedures and all documentation required to determine the results.RI$WWDFKHG3DJHV 7XUELQH3URGXFW3LSLQJ6XPS7HVWLQJ7UDLQLQJDQG&HUWLILFDWLRQV(List applicable certifications.)([SLUDWLRQ'DWH ;9, &200(176 Provide any additional comments here. NA Unknown PEI-1200 1 ICC Tech 8819073 9/8/2020 Incon level 4 1027843710 10/4/2020 SWRCB, January 2002 ;9785%,1(352'8&73,3,1*68037(67,1*,1)250$7,21 Test Method Developed By: Sump Manufacturer Industry Standard Professional Engineer Other (Specify) Test Method Used: Pressure Vacuum Hydrostatic Other (Specify) Test Equipment Used:Equipment Resolution: Sump #Sump #Sump #Sump # Sump Diameter: Sump Depth: Sump Material: Height from Tank Top to Top of Highest Piping Penetration: Height from Tank Top to Lowest Electrical Penetration: Condition of sump prior to testing: Portion of Sump Tested1 Does turbine shut down when sump sensor detects liquid (both product and water)?* Yes No NA Yes No NA Yes No NA Yes No NA Turbine shutdown response time Is system programmed for fail-safe shutdown?* Yes No NA Yes No NA Yes No NA Yes No NA Was fail-safe verified to be operational?* Yes No NA Yes No NA Yes No NA Yes No NA Wait time between applying pressure/vacuum/water and starting test: Test Start Time: Initial Reading (RI): Test End Time: Final Reading (RF): Test Duration: Change in Reading (RF-RI): Pass/Fail Threshold or Criteria: Test Result: Pass Fail Pass Fail Pass Fail Pass Fail Was sensor removed for testing? Yes No NA Yes No NA Yes No NA Yes No NA Was sensor properly replaced and verified functional after testing? Yes No NA Yes No NA Yes No NA Yes No NA Comments – (include information on repairs made prior to testing, and recommended follow-up for failed tests) 1 If the entire depth of the sump is not tested, specify how much was tested. If the answer to any of the questions indicated with an asterisk (*) is “NO” or “NA”, the entire sump must be tested. (See SWRCB LG-160) ✔ ✔ Incon 0.002” 87 91 Diesel 36”36”36” 48”48”48” Fiberglass Fiberglass Fiberglass 24”24”24” 17” 17”17” Clean and dry Clean and dry Clean and dry 29” 29”29” ✔ ✔✔ N/A N/A N/A ✔ ✔✔ ✔ ✔✔ 30 minutes 30 minutes 30 minutes 9:04 am 9:04 am 10:14 am 6.017”5.928”3.212” 9:20 am 9:20 am 10:9 am 6.017”5.929”3.213” 15 minutes 15 minutes 15 minutes 0.000”0.001”0.001” 0.002”0.002”0.002” ✔✔✔ ✔ ✔✔ ✔ ✔✔ 8'& 8QGHU'LVSHQVHU&RQWDLQPHQW,' ,GHQWLILFDWLRQ 81 ZZZXQLGRFVRUJ 5HY 81'(5*5281'6725$*(7$1. 6(&21'$5<&217$,10(177(67,1*5(3257)250 3DJHRI  ;;, 81'(5',63(16(5&217$,10(177(67,1*,1)250$7,21 0DQXIDFWXUHU V ,GHQWLI\8'&,'IURP6HFWLRQ,,,IRUHDFK0DQXIDFWXUHU     7HVW0HWKRG8VHG0DQXIDFWXUHU*XLGHOLQHV(Specify) ,QGXVWU\&RGHRU(QJLQHHULQJ6WDQGDUG (Specify) (QJLQHHUHG0HWKRG(Specify) Attach the testing procedures and all documentation required to determine the results.RI$WWDFKHG3DJHV 8'&7HVWLQJ7UDLQLQJDQG&HUWLILFDWLRQV(List applicable certifications.)([SLUDWLRQ'DWH ;;,, &200(176 Provide any additional comments here. If the facility has more components than this form accommodates, additional copies of these pages may be attached. Total containment PEI-1200 2 ICC Tech 8819073 9/8/2020 Incon level 4 1027843710 10/4/2020 SWRCB, January 2002 ;;,81'(5',63(16(5&217$,10(177(67,1*,1)250$7,21 Test Method Developed By: UDC Manufacturer Industry Standard Professional Engineer Other (Specify) Test Method Used: Pressure Vacuum Hydrostatic Other (Specify) Test Equipment Used: Equipment Resolution: UDC # UDC # UDC # UDC # UDC Manufacturer: UDC Material: UDC Depth: Height from UDC Bottom to Top of Highest Piping Penetration: Height from UDC Bottom to Lowest Electrical Penetration: Condition of UDC prior to testing: Portion of UDC Tested1 Does turbine shut down when UDC sensor detects liquid (both product and water)?* Yes No NA Yes No NA Yes No NA Yes No NA Turbine shutdown response time Is system programmed for fail- safe shutdown?* Yes No NA Yes No NA Yes No NA Yes No NA Was fail-safe verified to be operational?* Yes No NA Yes No NA Yes No NA Yes No NA Wait time between applying pressure/vacuum/water and starting test Test Start Time: Initial Reading (RI): Test End Time: Final Reading (RF): Test Duration: Change in Reading (RF-RI): Pass/Fail Threshold or Criteria: Test Result: Pass Fail Pass Fail Pass Fail Pass Fail Was sensor removed for testing? Yes No NA Yes No NA Yes No NA Yes No NA Was sensor properly replaced and verified functional after testing? Yes No NA Yes No NA Yes No NA Yes No NA Comments – (include information on repairs made prior to testing, and recommended follow-up for failed tests) 1 If the entire depth of the UDC is not tested, specify how much was tested. If the answer to any of the questions indicated with an asterisk (*) is “NO” or “NA”, the entire UDC must be tested. (See SWRCB LG-160) ✔ ✔ Incon 0.002” 9-10 11-12 13-14 15-16 Total containment Total containment Total containment Total containment Plastic Plastic Plastic Plastic 30”30 “30”30” 13”13”13”13” 0”0”0”0” Clean and dry Clean and dry Clean and dry Clean and dry 17”17”17”17” ✔ ✔✔✔ N/A N/A N/A N/A ✔ ✔✔✔ ✔ ✔✔ 30 minutes 30 minutes 30 minutes 30 minutes 9:41 am 10:43 am 10:43 am 1:02 pm 3.704” 1.256” 3.318”3.505” 9:57 am 10:58 am 10:58 am 1:17 pm 3.704” 1.042” 3.301”3.065” 15 minutes 15 minutes 15 minutes 15 minutes 0.000” 0.214” 0.017” 0.440” 0.002” 0.002” 0.002” 0.002” ✔✔✔✔ ✔✔✔✔ ✔ ✔✔✔ Need to replace piping penetrations and retest. SWRCB, January 2002 Test Method Developed By: UDC Manufacturer Industry Standard Professional Engineer Other (Specify) Test Method Used: Pressure Vacuum Hydrostatic Other (Specify) Test Equipment Used: Equipment Resolution: UDC # UDC # UDC # UDC # UDC Manufacturer: UDC Material: UDC Depth: Height from UDC Bottom to Top of Highest Piping Penetration: Height from UDC Bottom to Lowest Electrical Penetration: Condition of UDC prior to testing: Portion of UDC Tested1 Does turbine shut down when UDC sensor detects liquid (both product and water)?* Yes No NA Yes No NA Yes No NA Yes No NA Turbine shutdown response time Is system programmed for fail- safe shutdown?* Yes No NA Yes No NA Yes No NA Yes No NA Was fail-safe verified to be operational?* Yes No NA Yes No NA Yes No NA Yes No NA Wait time between applying pressure/vacuum/water and starting test Test Start Time: Initial Reading (RI): Test End Time: Final Reading (RF): Test Duration: Change in Reading (RF-RI): Pass/Fail Threshold or Criteria: Test Result: Pass Fail Pass Fail Pass Fail Pass Fail Was sensor removed for testing? Yes No NA Yes No NA Yes No NA Yes No NA Was sensor properly replaced and verified functional after testing? Yes No NA Yes No NA Yes No NA Yes No NA Comments – (include information on repairs made prior to testing, and recommended follow-up for failed tests) 1 If the entire depth of the UDC is not tested, specify how much was tested. If the answer to any of the questions indicated with an asterisk (*) is “NO” or “NA”, the entire UDC must be tested. (See SWRCB LG-160) ;;,81'(5',63(16(5&217$,10(177(67,1*,1)250$7,21 ✔ ✔ Incon 0.002” 17-18 19-20 Total containment Total containment Plastic Plastic 30”30” 13”13” 0”0” Clean and dry Clean and dry 17”17” ✔ ✔✔ N/A N/A ✔ ✔ ✔ ✔ 30 minutes 30 minutes 1:02 pm 1:02 pm 4.046” 2.013” 1:18 pm 1:18 pm 4.047” 2.013” 15 minutes 15 minutes 0.001” 0.000” 0.002” 0.002” ✔✔ ✔✔ ✔ ✔