Loading...
HomeMy WebLinkAbout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ame as Facility Name or DBA-Doing Business As) %XVLQHVV6LWH$GGUHVV &LW\ =,3&RGH ,, 81'(5*5281'6725$*(7$1.6(59,&(7(&+1,&,$1,1)250$7,21 1DPHRI&RPSDQ\3HUIRUPLQJWKH&HUWLILFDWLRQ 3KRQH 0DLOLQJ$GGUHVV 1DPHRI8676HUYLFH7HFKQLFLDQ3HUIRUPLQJWKH&HUWLILFDWLRQ(Print as shown on the ICC Certification) &RQWUDFWRU7DQN7HVWHU/LFHQVH ,&&&HUWLILFDWLRQ ,&&&HUWLILFDWLRQ([SLUDWLRQ'DWH 0RQLWRULQJ6\VWHP7UDLQLQJDQG&HUWLILFDWLRQV(List all applicable certifications.) ([SLUDWLRQ'DWH ,,, 5(68/762)7(67,1*6(59,&,1* Indicate and attach the following reports if the monitoring equipment is capable of generating either.<11$0RQLWRULQJ6\VWHP6HWXS$ODUP+LVWRU\5HSRUW :DVDQ\PRQLWRULQJHTXLSPHQWUHSODFHG" (If “Yes,” identify the specific devices replaced and list the manufacturer and model for all replacement parts in section IV below.) :DVGDPDJHGHEULVRUOLTXLGIRXQGLQVLGHDQ\VHFRQGDU\FRQWDLQPHQWV\VWHPV" (If “Yes,” describe what was found in section IV below.) ,VDOOPRQLWRULQJHTXLSPHQWRSHUDWLRQDOSHUPDQXIDFWXUHU¶VVSHFLILFDWLRQV" (If “No,” describe why in section IV below.) ,9 &200(176 If directed to use this section, describe how and when the issues were or will be corrected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aco #3347 Fastrip #26 2698 Oswell Street Bakersfield 93306 16250 Meacham Road, Bakersfield, CA 93314 Aaron Perrigo 804904 8485827 8/16/2022 Veeder Root B47853 8/1/2022 Confidence UST Services, Inc. (800) 339-9930 ,' ,GHQWLILFDWLRQ6: 6LQJOH:DOOHG93+ 9DFXXP3UHVVXUH+\GURVWDWLF//' /LQH/HDN'HWHFWRU 81 ZZZXQLGRFVRUJ 5HY 81'(5*5281'6725$*(7$1. 021,725,1*6<67(0&(57,),&$7,21)250 3DJHRI  9, ,19(1725<2)(48,30(17&(57,),(' A separate Monitoring System Certification Form must be prepared for each monitoring system control panel. 0DNHRI0RQLWRULQJ6\VWHP&RQWURO3DQHO  0RGHORI0RQLWRULQJ6\VWHP&RQWURO3DQHO  6RIWZDUH9HUVLRQ,QVWDOOHG  Check the appropriate boxes to indicate specific equipment inspected/serviced. 0RQLWRULQJ'HYLFH8VHG'HYLFH0RGHO0RQLWRULQJ'HYLFH8VHG'HYLFH0RGHO 7$1.,' (By tank number, stored product, etc.) 7$1.,' (By tank number, stored product, etc.) ,Q7DQN*DXJLQJ(SW Tank),Q7DQN*DXJLQJ(SW Tank) $QQXODU6SDFHRU9DXOW6HQVRU$QQXODU6SDFHRU9DXOW6HQVRU 93+6HQVRU93+6HQVRU 3URGXFW3LSLQJ3URGXFW3LSLQJ 0HFKDQLFDO//'0HFKDQLFDO//' (OHFWURQLF//'(OHFWURQLF//' 93+6HQVRU 3LSLQJ 93+6HQVRU 3LSLQJ  6XPS6HQVRU6XPS6HQVRU 93+6HQVRU 6XPS 93+6HQVRU 6XPS  )LOO3LSLQJ)LOO3LSLQJ 93+6HQVRU 3LSLQJ 93+6HQVRU 3LSLQJ  6XPS6HQVRU6XPS6HQVRU 93+6HQVRU 6XPS 93+6HQVRU 6XPS  9HQW3LSLQJ9HQW3LSLQJ 93+6HQVRU 3LSLQJ 93+6HQVRU 3LSLQJ  6XPS6HQVRU6XPS6HQVRU 93+6HQVRU 6XPS 93+6HQVRU 6XPS  9DSRU5HFRYHU\3LSLQJ9DSRU5HFRYHU\3LSLQJ 93+6HQVRU 3LSLQJ 93+6HQVRU 3LSLQJ  6XPS6HQVRU6XPS6HQVRU 93+6HQVRU 6XPS 93+6HQVRU 6XPS  0RQLWRULQJ'HYLFH8VHG 'HYLFH0RGHO0RQLWRULQJ'HYLFH8VHG 'HYLFH0RGHO 7$1.,' (By tank number, stored product, etc.) 7$1.,' (By tank number, stored product, etc.) ,Q7DQN*DXJLQJ(SW Tank),Q7DQN*DXJLQJ(SW Tank) $QQXODU6SDFHRU9DXOW6HQVRU$QQXODU6SDFHRU9DXOW6HQVRU 93+6HQVRU93+6HQVRU 3URGXFW3LSLQJ3URGXFW3LSLQJ 0HFKDQLFDO//'0HFKDQLFDO//' (OHFWURQLF//'(OHFWURQLF//' 93+6HQVRU 3LSLQJ 93+6HQVRU 3LSLQJ  6XPS6HQVRU6XPS6HQVRU 93+6HQVRU 6XPS 93+6HQVRU 6XPS  )LOO3LSLQJ)LOO3LSLQJ 93+6HQVRU 3LSLQJ 93+6HQVRU 3LSLQJ  6XPS6HQVRU6XPS6HQVRU 93+6HQVRU 6XPS 93+6HQVRU 6XPS  9HQW3LSLQJ9HQW3LSLQJ 93+6HQVRU 3LSLQJ 93+6HQVRU 3LSLQJ  6XPS6HQVRU6XPS6HQVRU 93+6HQVRU 6XPS 93+6HQVRU 6XPS  9DSRU5HFRYHU\3LSLQJ9DSRU5HFRYHU\3LSLQJ 93+6HQVRU 3LSLQJ 93+6HQVRU 3LSLQJ  6XPS6HQVRU6XPS6HQVRU 93+6HQVRU 6XPS 93+6HQVRU 6XPS  Veeder Root TLS-350 330.02 T1 Unl 847390-107 794390-420 FX1V 794380-208 T2 Unl slave 847390-107 794390-420 794380-208 T3 Prem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pecify in section VII.)2WKHU(Specify in section VII.) 2WKHU0RQLWRUHG&RPSRQHQW,'2WKHU0RQLWRUHG&RPSRQHQW,' 2WKHU(Specify in section VII.)2WKHU(Specify in section VII.) 2WKHU0RQLWRUHG&RPSRQHQW,'2WKHU0RQLWRUHG&RPSRQHQW,' 2WKHU(Specify in section VII.)2WKHU(Specify in section VII.) Include information for every underground storage tank component monitored by this monitoring system control panel. If the monitoring system control panel monitors more components than this form accommodates, additional copies of these pages may be attached. 9,, &200(176 Use this section to provide additional comments about the inventory of the equipment certified.  Trans Sump N 794380-208 Trans Sump S 794380-208 1-2 794389-208 3-4 794380-208 5-6 794380-208 7-8 794380-208 < <HV1 1R1$ 1RW$SSOLFDEOH 81 ZZZXQLGRFVRUJ 5HY 81'(5*5281'6725$*(7$1. 021,725,1*6<67(0&(57,),&$7,21)250 3DJHRI  9,,, 021,725,1*6<67(0$1'352*5$00,1* This section must be completed if a monitoring panel is used to perform leak detection monitoring.<11$ $UHWKHYLVXDODQGDXGLEOHDODUPVRSHUDWLRQDO" :HUHDOOVHQVRUVYLVXDOO\LQVSHFWHGIRUNLQNVDQGEUHDNVLQWKHFDEOHVDQGIRUUHVLGXDOEXLOGXSWRHQVXUHWKDWIORDWVPRYHIUHHO\ IXQFWLRQDOO\WHVWHGDQGFRQILUPHGRSHUDWLRQDO" :HUHDOOVHQVRUVLQVWDOOHGDWORZHVWSRLQWRIVHFRQGDU\FRQWDLQPHQWDQGSRVLWLRQHGVRWKDWRWKHUHTXLSPHQWZLOOQRWLQWHUIHUHZLWK WKHLUSURSHURSHUDWLRQ" :DVPRQLWRULQJV\VWHPVHWXSUHYLHZHGWRHQVXUHSURSHUVHWWLQJV" :DVWKHPRQLWRULQJSDQHO¶VEDFNXSEDWWHU\YLVXDOO\LQVSHFWHGIXQFWLRQDOO\WHVWHGDQGFRQILUPHGRSHUDWLRQDO" 'RHVWKHIORZRIIXHOVWRSDWWKHGLVSHQVHULIDOHDNLVGHWHFWHGLQWKHXQGHUGLVSHQVHUFRQWDLQPHQW" 'RHVWKHWXUELQHDXWRPDWLFDOO\VKXWGRZQLIWKHSLSLQJVHFRQGDU\FRQWDLQPHQWPRQLWRULQJV\VWHPIDLOVWRRSHUDWHRULVHOHFWULFDOO\ GLVFRQQHFWHG" 'RHVWKHWXUELQHDXWRPDWLFDOO\VKXWGRZQLIWKHSLSLQJVHFRQGDU\FRQWDLQPHQWPRQLWRULQJV\VWHPGHWHFWVDOHDN" :KLFKVHQVRUVLQLWLDWHSRVLWLYHVKXWGRZQ"(Check all that apply.)6XPS8QGHU'LVSHQVHU&RQWDLQPHQW ,IDODUPVDUHUHOD\HGWRDUHPRWHPRQLWRULQJVWDWLRQLVDOOFRPPXQLFDWLRQVHTXLSPHQW HJPRGHP RSHUDWLRQDO" For any answer of “N” above, describe in Section IX how and when these deficiencies were or will be corrected. ,; &200(176 ; ,17$1.*$8*,1*7(67,1* &KHFNWKLVER[LIWDQNJDXJLQJLVXVHGRQO\IRULQYHQWRU\FRQWURO(Do not complete this section.) <11$&KHFNWKLVER[LI12WDQNJDXJLQJHTXLSPHQWLVLQVWDOOHG (Do not complete this section.) This section must be completed if in-tank gauging is used to perform leak detection monitoring. +DVDOOLQSXWZLULQJEHHQLQVSHFWHGIRUNLQNVDQGEUHDNVLQWKHFDEOHVDQGIRUSURSHUHQWU\DQGWHUPLQDWLRQLQFOXGLQJWHVWLQJIRU JURXQGIDXOWV" :HUHDOOLQWDQNJDXJLQJSUREHVYLVXDOO\LQVSHFWHGIRUGDPDJHDQGUHVLGXHEXLOGXSWRHQVXUHWKDWIORDWVPRYHIUHHO\IXQFWLRQDOO\ WHVWHGDQGFRQILUPHGRSHUDWLRQDO" :DVDFFXUDF\RIV\VWHP¶VSURGXFWOHYHOUHDGLQJVWHVWHG" :DVDFFXUDF\RIV\VWHP¶VZDWHUOHYHOUHDGLQJVWHVWHG" :HUHDOOSUREHVUHLQVWDOOHGSURSHUO\" :HUHDOOLWHPVRQWKHHTXLSPHQWPDQXIDFWXUHU¶VPDLQWHQDQFHFKHFNOLVWFRPSOHWHG" For any answer of “N” above, describe in Section XI how and when these deficiencies were or will be corrected. ;, &200(176 *3+ *DOORQV3HU+RXU< <HV1 1R1$ 1RW$SSOLFDEOH93+ 9DFXXP3UHVVXUH+\GURVWDWLF,' ,GHQWLILFDWLRQ 81 ZZZXQLGRFVRUJ5HY 81'(5*5281'6725$*(7$1. 021,725,1*6<67(0&(57,),&$7,21)250 3DJHRI  ;,, /,1(/($.'(7(&7257(67,1* &KHFNWKLVER[LIOLQHOHDNGHWHFWRUV //' DUH127LQVWDOOHG(Do not complete this section.)<11$This section must be completed if LLDs are installed. :DVDOHDNVLPXODWHGWRYHULI\//'SHUIRUPDQFH" (Check all that apply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¶VPDLQWHQDQFHFKHFNOLVWFRPSOHWHG" :HUHDOO//'VFRQILUPHGRSHUDWLRQDOZLWKLQUHJXODWRU\UHTXLUHPHQWV" For any answer of “N” above, describe in Section XIII how and when these issues were or will be corrected. ;,,, &200(176 ;,9 9$&88035(6685(+<'5267$7,&021,725,1*(48,30(177(67,1* &KHFNWKLVER[LI93+PRQLWRULQJLV127XVHG(Do not complete this section.) This section must be completed if VPH monitoring is used to perform leak detection monitoring. 6\VWHP7\SH 0DUNDOOWKDWDSSO\ 9DFXXP3UHVVXUH+\GURVWDWLF 6HQVRU,'&RPSRQHQW 6 0RQLWRUHG%\7KLV6HQVRU 6HQVRU)XQFWLRQDOLW\ 7HVW ,QWHUVWLWLDO&RPPXQLFDWLRQ 7HVW 3DVV )DLO 3DVV )DLO 3DVV)DLO3DVV)DLO 3DVV)DLO3DVV)DLO 3DVV)DLO3DVV)DLO 3DVV)DLO3DVV)DLO 3DVV)DLO3DVV)DLO 3DVV)DLO3DVV)DLO 3DVV)DLO3DVV)DLO 3DVV)DLO3DVV)DLO 3DVV)DLO3DVV)DLO 3DVV)DLO3DVV)DLO 3DVV)DLO3DVV)DLO +RZZDVLQWHUVWLWLDOFRPPXQLFDWLRQYHULILHG"6LPXODWHG/HDNDW)DU(QGVRIWKH,QWHUVWLWLDO6SDFH9LVXDO,QVSHFWLRQ 2WKHU(Describe the method in section XV below.)*DXJH :DVWKHYDFXXPRUSUHVVXUHUHVWRUHGWRRSHUDWLQJOHYHOVLQDOOLQWHUVWLWLDOVSDFHV"<HV1R(Describe the reason in section XV below.) For any answer of “Fail” above, describe in Section XV how and when these issues were or will be corrected. ;9 &200(176 Jaco 3347 Setup Responses Received: 200 FASTRIP 347 2698 OSWELL ST BAKERSFIELD 93306 661-872-8721 AUG 27, 2020 11:33 AM TANK PRODUCT GALLONS INCHES WATER DEG F ULLAGE 1 UNL 1 8923 66.86 0.8 83.8 3077 2 DIESEL 3771 33.79 0.8 87.8 8229 3 PNL 8239 62.28 0.0 86.1 3761 4 UNL 2 9171 68.57 0.6 82.9 2829 I90500 AUG 27, 2020 11:33 AM SOFTWARE REVISION LEVEL VERSION 330.01 SOFTWARE# 346330-100-B CREATED - 10.07.23.17.25 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD I50500 AUG 27, 2020 11:33 AM SYSTEM TYPE AND LANGUAGE FLAG SYSTEM UNITS U.S. SYSTEM LANGUAGE ENGLISH SYSTEM DATE/TIME FORMAT MON DD YYYY HH:MM:SS xM I50201 AUG 27, 2020 11:33 AM SHIFT TIME 1 : 6:00 AM I50202 AUG 27, 2020 11:33 AM SHIFT TIME 2 : DISABLED I50203 AUG 27, 2020 11:33 AM SHIFT TIME 3 : DISABLED I50204 AUG 27, 2020 11:33 AM SHIFT TIME 4 : DISABLED I54600 AUG 27, 2020 11:33 AM TANK PER TST NEEDED WRN: DISABLED I54900 AUG 27, 2020 11:33 AM TANK ANN TST NEEDED WRN: DISABLED I55300 AUG 27, 2020 11:33 AM LINE RE-ENABLE METHOD PASS LINE TEST I55600 AUG 27, 2020 11:33 AM LINE PER TST NEEDED WRN: DISABLED I55900 AUG 27, 2020 11:33 AM LINE ANN TST NEEDED WRN: DISABLED I50D00 AUG 27, 2020 11:33 AM PRINT TC VOLUMES ENABLED I50E00 AUG 27, 2020 11:33 AM TEMP COMPENSATION VALUE (DEG F ): 60.0 I60B00 AUG 27, 2020 11:33 AM STICK HEIGHT OFFSET ENABLE STATUS DISABLED I51400 AUG 27, 2020 11:33 AM H-PROTOCOL DATA FORMAT HEIGHT I51A01 AUG 27, 2020 11:33 AM DAYLIGHT SAVING TIME ENABLED ON I51B00 AUG 27, 2020 11:33 AM DAYLIGHT SAVING TIME START DATE MAR WEEK 2 SUN 2:00 AM END DATE NOV WEEK 1 SUN 2:00 AM I51600 AUG 27, 2020 11:33 AM RE-DIRECT LOCAL PRINTOUT DISABLED I50400 AUG 27, 2020 11:33 AM 232 SECURITY CODE PORT SECURITY CODE STATUS 1 000000 DISABLED 2 000000 DISABLED 3 000000 DISABLED 4 000000 DISABLED 5 000000 DISABLED 6 000000 DISABLED I21900 AUG 27, 2020 11:33 AM TANK CHART SECURITY DISABLED I5BD00 AUG 27, 2020 11:33 AM CUSTOM ALARM LABELS DISABLED I56000 AUG 27, 2020 11:33 AM MASS/DENSITY DISABLED I88101 AUG 27, 2020 11:33 AM PORT SETTINGS: COMM BOARD : 1 (EDIM ) RS-232 SECURITY CODE : DISABLED I88102 AUG 27, 2020 11:33 AM PORT SETTINGS: COMM BOARD : 2 (RS-232) BAUD RATE : 9600 PARITY : NONE STOP BIT : 1 STOP DATA LENGTH: 8 DATA RS-232 SECURITY CODE : DISABLED I88103 AUG 27, 2020 11:33 AM PORT SETTINGS: COMM BOARD : 3 (RS-232) BAUD RATE : 9600 PARITY : NONE STOP BIT : 1 STOP DATA LENGTH: 8 DATA RS-232 SECURITY CODE : DISABLED I88104 AUG 27, 2020 11:33 AM I88105 AUG 27, 2020 11:33 AM I88106 AUG 27, 2020 11:33 AM I52000 AUG 27, 2020 11:33 AM RECEIVER AUTO DIAL TYPE & START TIME RCVR LOCATION LABEL DIAL TYPE START TIME 1 ON DATE ??? 27, 2020 DISABLED 2 ON DATE ??? 27, 2020 DISABLED 3 ON DATE ??? 27, 2020 DISABLED 4 ON DATE ??? 27, 2020 DISABLED 5 ON DATE ??? 27, 2020 DISABLED 6 ON DATE ??? 27, 2020 DISABLED 7 ON DATE ??? 27, 2020 DISABLED 8 ON DATE ??? 27, 2020 DISABLED I60100 AUG 27, 2020 11:33 AM TANK CONFIGURATION DEVICE LABEL CONFIGURED 1 UNL 1 ON 2 DIESEL ON 3 PNL ON 4 UNL 2 ON I60200 AUG 27, 2020 11:33 AM TANK PRODUCT LABEL TANK PRODUCT LABEL 1 UNL 1 2 DIESEL 3 PNL 4 UNL 2 I60300 AUG 27, 2020 11:33 AM TANK PRODUCT CODE TANK PRODUCT LABEL 1 UNL 1 1 2 DIESEL 2 3 PNL 3 4 UNL 2 4 I60900 AUG 27, 2020 11:33 AM TANK THERMAL COEFFICIENT TANK PRODUCT LABEL 1 UNL 1 0.000700 2 DIESEL 0.000450 3 PNL 0.000700 4 UNL 2 0.000700 I60700 AUG 27, 2020 11:33 AM TANK DIAMETER TANK PRODUCT LABEL INCHES 1 UNL 1 96.00 2 DIESEL 96.00 3 PNL 96.00 4 UNL 2 96.00 I60A00 AUG 27, 2020 11:33 AM TANK FULL VOLUME TANK PRODUCT LABEL TANK PROFILE GALLONS 1 UNL 1 1 PT 12000 2 DIESEL 1 PT 12000 3 PNL 1 PT 12000 4 UNL 2 1 PT 12000 I60400 AUG 27, 2020 11:33 AM TANK FULL VOLUME TANK PRODUCT LABEL GALLONS 1 UNL 1 12000 2 DIESEL 12000 3 PNL 12000 4 UNL 2 12000 I60500 AUG 27, 2020 11:33 AM TANK 4 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 UNL 1 12000 0 0 0 2 DIESEL 12000 0 0 0 3 PNL 12000 0 0 0 4 UNL 2 12000 0 0 0 I60600 AUG 27, 2020 11:33 AM TANK 20 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 UNL 1 12000 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 DIESEL 12000 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3 PNL 12000 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4 UNL 2 12000 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 I61500 AUG 27, 2020 11:33 AM TANK PRODUCT LABEL METER DATA 1 UNL 1 NO 2 DIESEL NO 3 PNL NO 4 UNL 2 NO I62F00 AUG 27, 2020 11:33 AM MAG PROBE FLOAT SIZE TANK PRODUCT LABEL FLOAT SIZE: 1 UNL 1 4.0 IN. 2 DIESEL 4.0 IN. 3 PNL 4.0 IN. 4 UNL 2 3.0 IN. I62700 AUG 27, 2020 11:33 AM TANK HIGH WATER WARNING LIMIT TANK PRODUCT LABEL INCHES 1 UNL 1 2.0 2 DIESEL 2.0 3 PNL 2.0 4 UNL 2 2.0 9999FF1B I62400 AUG 27, 2020 11:33 AM TANK HIGH WATER LEVEL LIMIT TANK PRODUCT LABEL INCHES 1 UNL 1 3.0 2 DIESEL 3.0 3 PNL 3.0 4 UNL 2 3.0 I62800 AUG 27, 2020 11:33 AM TANK MAXIMUM VOLUME LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 1 12000 2 DIESEL 12000 3 PNL 12000 4 UNL 2 12000 I62300 AUG 27, 2020 11:33 AM TANK OVERFILL LEVEL LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 1 10800 2 DIESEL 10800 3 PNL 10800 4 UNL 2 10800 I62200 AUG 27, 2020 11:33 AM TANK HIGH PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 1 11400 2 DIESEL 11400 3 PNL 11400 4 UNL 2 11400 I62900 AUG 27, 2020 11:33 AM TANK DELIVERY REQUIRED LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 1 1200 2 DIESEL 1200 3 PNL 1200 4 UNL 2 1200 I62100 AUG 27, 2020 11:33 AM TANK LOW PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 1 1200 2 DIESEL 1200 3 PNL 1200 4 UNL 2 1200 I62600 AUG 27, 2020 11:33 AM TANK LEAK ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 1 99 2 DIESEL 99 3 PNL 99 4 UNL 2 99 I62500 AUG 27, 2020 11:33 AM TANK SUDDEN LOSS LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 1 99 2 DIESEL 99 3 PNL 99 4 UNL 2 99 I60800 AUG 27, 2020 11:33 AM TANK TILT TANK PRODUCT LABEL INCHES 1 UNL 1 0.00 2 DIESEL 0.00 3 PNL 0.00 4 UNL 2 0.00 I60B00 AUG 27, 2020 11:33 AM STICK HEIGHT OFFSET ENABLE STATUS DISABLED I60C00 AUG 27, 2020 11:33 AM TANK STICK HEIGHT OFFSET TANK PRODUCT LABEL INCHES 1 UNL 1 0.00 2 DIESEL 0.00 3 PNL 0.00 4 UNL 2 0.00 I61200 AUG 27, 2020 11:33 AM TANK MANIFOLDED PARTNERS TANK PRODUCT LABEL SIPHON MANIFOLDED TANKS LINE MANIFOLDED TANKS 1 UNL 1 4 NONE 2 DIESEL NONE NONE 3 PNL NONE NONE 4 UNL 2 1 NONE I63600 AUG 27, 2020 11:33 AM PERIODIC LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 UNL 1 120 2 DIESEL 120 3 PNL 120 4 UNL 2 120 I62A00 AUG 27, 2020 11:33 AM ANNUAL LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 UNL 1 0 2 DIESEL 0 3 PNL 0 4 UNL 2 0 I62C00 AUG 27, 2020 11:33 AM TANK PERIODIC TEST TYPE TANK PRODUCT LABEL PERIODIC TEST TYPE 1 UNL 1 STANDARD 2 DIESEL STANDARD 3 PNL STANDARD 4 UNL 2 STANDARD I62D00 AUG 27, 2020 11:33 AM TANK LEAK TEST FAIL ALARMS TANK PRODUCT LABEL 1 UNL 1 GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED 2 DIESEL GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED 3 PNL GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED 4 UNL 2 GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED I63100 AUG 27, 2020 11:33 AM TANK LEAK TEST AVERAGING TANK PRODUCT LABEL ANNUAL PERIODIC 1 UNL 1 OFF OFF 2 DIESEL OFF OFF 3 PNL OFF OFF 4 UNL 2 OFF OFF I63000 AUG 27, 2020 11:33 AM IN-TANK LEAK TEST NOTIFY TANK PRODUCT LABEL TANK TEST NOTIFY: 1 UNL 1 OFF 2 DIESEL OFF 3 PNL OFF 4 UNL 2 OFF I63200 AUG 27, 2020 11:33 AM TANK TEST SIPHON BREAK TANK PRODUCT LABEL SIPHON BREAK 1 UNL 1 OFF 2 DIESEL OFF 3 PNL OFF 4 UNL 2 OFF I61000 AUG 27, 2020 11:33 AM TANK DELIVERY DELAY TANK PRODUCT LABEL 1 UNL 1 1 2 DIESEL 1 3 PNL 1 4 UNL 2 1 I63A00 AUG 27, 2020 11:33 AM LOW LEVEL PUMP THRESHOLD FOR SEQUENTIAL LINE MANIFOLD TANK PRODUCT LABEL PUMP THRESHOLD 1 UNL 1 10.00% 2 DIESEL 10.00% 3 PNL 10.00% 4 UNL 2 10.00% I61100 AUG 27, 2020 11:33 AM LEAK TEST METHOD - - - - - - - - - - - - TEST ON DATE : ALL TANK JUL 23, 2010 START TIME : DISABLED TEST RATE :0.20 GAL/HR DURATION : 2 HOURS TST EARLY STOP:DISABLED I61300 AUG 27, 2020 11:33 AM CSLD PROBABLITY OF DETECTION I61400 AUG 27, 2020 11:33 AM CSLD CLIMATE FACTOR I61600 AUG 27, 2020 11:33 AM TANK PRODUCT LABEL CAL UPDATE 1 UNL 1 IMMEDIATE 2 DIESEL IMMEDIATE 3 PNL IMMEDIATE 4 UNL 2 IMMEDIATE I61A00 AUG 27, 2020 11:33 AM IN-TANK LEAK TEST EARLY STOP TANK PRODUCT LABEL TST EARLY STOP: 1 UNL 1 DISABLED 2 DIESEL DISABLED 3 PNL DISABLED 4 UNL 2 DISABLED I61B00 AUG 27, 2020 11:33 AM IN-TANK LEAK GROSS TEST AUTO-CONFIRM I61C00 AUG 27, 2020 11:33 AM CSLD REPORT ONLY I62B00 AUG 27, 2020 11:33 AM TANK LAST ANNUAL TEST TANK PRODUCT LABEL DATE 1 UNL 1 ??? 0, 0 2 DIESEL ??? 0, 0 3 PNL ??? 0, 0 4 UNL 2 ??? 0, 0 I63300 AUG 27, 2020 11:33 AM LEAK TEST REPORT FORMAT: NORMAL I63400 AUG 27, 2020 11:33 AM RECONCILIATION WARNING LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 1 0 2 DIESEL 0 3 PNL 0 4 UNL 2 0 I63500 AUG 27, 2020 11:33 AM RECONCILIATION ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 1 1 2 DIESEL 1 3 PNL 1 4 UNL 2 1 I63900 AUG 27, 2020 11:33 AM ACCU CHART END SHAPE FACTOR TANK PRODUCT LABEL 1 UNL 1 END FACTOR: NONE 2 DIESEL END FACTOR: NONE 3 PNL END FACTOR: NONE 4 UNL 2 END FACTOR: NONE I78000 AUG 27, 2020 11:33 AM I77700 AUG 27, 2020 11:33 AM I77800 AUG 27, 2020 11:33 AM I78C00 AUG 27, 2020 11:33 AM I78300 AUG 27, 2020 11:33 AM I78F00 AUG 27, 2020 11:33 AM I78700 AUG 27, 2020 11:33 AM I70200 AUG 27, 2020 11:33 AM LIQUID LABEL DEVICE LABEL 1 UNL 1 STP 2 UNL 1 ANN 3 DSL STP 4 DSL ANN 5 6 PNL ANN 7 UNL 2 STP 8 UNL 2 ANN 9 DISP 1-2 10 DISP 3-4 11 DISP 5-6 12 DISP 7-8 13 TRANS SUMP NO 14 TRANS SUMP SO 15 PNL STP 16 UNL 2 ANN I70300 AUG 27, 2020 11:33 AM LIQUID TYPE SENSOR LOCATION TYPE 1 UNL 1 STP TRI-STATE (SINGLE FLOAT) 2 UNL 1 ANN TRI-STATE (SINGLE FLOAT) 3 DSL STP TRI-STATE (SINGLE FLOAT) 4 DSL ANN TRI-STATE (SINGLE FLOAT) 5 TRI-STATE (SINGLE FLOAT) 6 PNL ANN TRI-STATE (SINGLE FLOAT) 7 UNL 2 STP TRI-STATE (SINGLE FLOAT) 8 UNL 2 ANN TRI-STATE (SINGLE FLOAT) 9 DISP 1-2 TRI-STATE (SINGLE FLOAT) 10 DISP 3-4 TRI-STATE (SINGLE FLOAT) 11 DISP 5-6 TRI-STATE (SINGLE FLOAT) 12 DISP 7-8 TRI-STATE (SINGLE FLOAT) 13 TRANS SUMP NO TRI-STATE (SINGLE FLOAT) 14 TRANS SUMP SO TRI-STATE (SINGLE FLOAT) 15 PNL STP TRI-STATE (SINGLE FLOAT) 16 UNL 2 ANN TRI-STATE (SINGLE FLOAT) I70400 AUG 27, 2020 11:33 AM LIQUID CATEGORY SENSOR LOCATION CATEGORY 1 UNL 1 STP STP SUMP 2 UNL 1 ANN ANNULAR SPACE 3 DSL STP STP SUMP 4 DSL ANN ANNULAR SPACE 5 OTHER SENSORS 6 PNL ANN ANNULAR SPACE 7 UNL 2 STP STP SUMP 8 UNL 2 ANN ANNULAR SPACE 9 DISP 1-2 DISPENSER PAN 10 DISP 3-4 DISPENSER PAN 11 DISP 5-6 DISPENSER PAN 12 DISP 7-8 DISPENSER PAN 13 TRANS SUMP NO PIPING SUMP 14 TRANS SUMP SO PIPING SUMP 15 PNL STP STP SUMP 16 UNL 2 ANN ANNULAR SPACE I74200 AUG 27, 2020 11:33 AM I74300 AUG 27, 2020 11:33 AM I74400 AUG 27, 2020 11:33 AM I74700 AUG 27, 2020 11:33 AM I74800 AUG 27, 2020 11:33 AM I74900 AUG 27, 2020 11:33 AM I7BC00 AUG 27, 2020 11:33 AM I80200 AUG 27, 2020 11:33 AM I80300 AUG 27, 2020 11:33 AM I80400 AUG 27, 2020 11:33 AM I80700 AUG 27, 2020 11:33 AM RELAY LABEL DEVICE LABEL 1 UNL 1 2 PNL 3 DSL 4 5 OVERFILL ALARM 6 7 8 I80900 AUG 27, 2020 11:34 AM RELAY ORIENTATION RELAY DESIGNATION ORIENTATION 1 UNL 1 NORMALLY OPEN 2 PNL NORMALLY OPEN 3 DSL NORMALLY CLOSED 4 NORMALLY OPEN 5 OVERFILL ALARM NORMALLY OPEN 6 NORMALLY OPEN 7 NORMALLY OPEN 8 NORMALLY OPEN I80B00 AUG 27, 2020 11:34 AM RELAY TANK ASSIGNMENT RELAY DESIGNATION TANK 1 UNL 1 1 2 PNL 3 3 DSL NONE 4 NONE 5 OVERFILL ALARM NONE 6 NONE 7 NONE 8 NONE I80A00 AUG 27, 2020 11:34 AM RELAY TYPE RELAY DESIGNATION TYPE 1 UNL 1 PUMP CONTROL OUTPUT 2 PNL PUMP CONTROL OUTPUT 3 DSL STANDARD 4 STANDARD 5 OVERFILL ALARM STANDARD 6 STANDARD 7 STANDARD 8 STANDARD I80C00 AUG 27, 2020 11:34 AM I80800 AUG 27, 2020 11:34 AM RELAY SETUP REPORT R 1:UNL 1 TYPE: PUMP CONTROL OUTPUT TANK #: 1 LIQUID SENSOR ALMS L 1:FUEL ALARM L 7:FUEL ALARM L 9:FUEL ALARM L10:FUEL ALARM L11:FUEL ALARM L12:FUEL ALARM L 1:SENSOR OUT ALARM L 7:SENSOR OUT ALARM L 9:SENSOR OUT ALARM L10:SENSOR OUT ALARM L11:SENSOR OUT ALARM L12:SENSOR OUT ALARM L 1:SHORT ALARM L 7:SHORT ALARM L 9:SHORT ALARM L10:SHORT ALARM L11:SHORT ALARM L12:SHORT ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD VP PRES FAIL ISD VP STATUS FAIL ISD HOSE ALARMS ALL:GROSS COLLECT FAIL ALL:DEGRD COLLECT FAIL ALL:FLOW COLLECT FAIL R 2:PNL TYPE: PUMP CONTROL OUTPUT TANK #: 3 LIQUID SENSOR ALMS L 9:FUEL ALARM L10:FUEL ALARM L11:FUEL ALARM L12:FUEL ALARM L15:FUEL ALARM L 9:SENSOR OUT ALARM L10:SENSOR OUT ALARM L11:SENSOR OUT ALARM L12:SENSOR OUT ALARM L15:SENSOR OUT ALARM L 9:SHORT ALARM L10:SHORT ALARM L11:SHORT ALARM L12:SHORT ALARM L15:SHORT ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD VP PRES FAIL ISD VP STATUS FAIL ISD HOSE ALARMS ALL:GROSS COLLECT FAIL ALL:DEGRD COLLECT FAIL ALL:FLOW COLLECT FAIL R 3:DSL TYPE: STANDARD NORMALLY CLOSED TANK #: NONE LIQUID SENSOR ALMS L 3:FUEL ALARM L 9:FUEL ALARM L10:FUEL ALARM L11:FUEL ALARM L12:FUEL ALARM L13:FUEL ALARM L14:FUEL ALARM L 3:SENSOR OUT ALARM L 9:SENSOR OUT ALARM L10:SENSOR OUT ALARM L11:SENSOR OUT ALARM L12:SENSOR OUT ALARM L13:SENSOR OUT ALARM L14:SENSOR OUT ALARM L 3:SHORT ALARM L 9:SHORT ALARM L10:SHORT ALARM L11:SHORT ALARM L12:SHORT ALARM L13:SHORT ALARM L14:SHORT ALARM R 4: TYPE: STANDARD NORMALLY OPEN TANK #: NONE - NO ALARM ASSIGNMENTS - R 5:OVERFILL ALARM TYPE: STANDARD NORMALLY OPEN TANK #: NONE IN-TANK ALARMS ALL:OVERFILL ALARM ALL:HIGH PRODUCT ALARM ALL:MAX PRODUCT ALARM R 6: TYPE: STANDARD NORMALLY OPEN TANK #: NONE - NO ALARM ASSIGNMENTS - R 7: TYPE: STANDARD NORMALLY OPEN TANK #: NONE - NO ALARM ASSIGNMENTS - R 8: TYPE: STANDARD NORMALLY OPEN TANK #: NONE - NO ALARM ASSIGNMENTS - I79000 AUG 27, 2020 11:34 AM EDIM:1 VR:349634-003-C TD:06.05.11.11.15 I79100 AUG 27, 2020 11:34 AM I72300 AUG 27, 2020 11:34 AM FASTRIP 347 2698 OSWELL ST BAKERSFIELD 93306 661-872-8721 SMARTSENSOR ASSIGNMENT DEVICE LABEL CATEGORY 01 PS 3-4 VAPOR PRESSURE 02 FM 1-2 AIR FLOW METER 03 FM 3-4 AIR FLOW METER 04 FM 5-6 AIR FLOW METER 05 FM 7-8 AIR FLOW METER 06 UNKNOWN 07 UNKNOWN 08 UNKNOWN 09 UNKNOWN 10 UNKNOWN 11 UNKNOWN 12 UNKNOWN 13 UNKNOWN 14 UNKNOWN 15 UNKNOWN 16 UNKNOWN 17 UNKNOWN 18 UNKNOWN 19 UNKNOWN 20 UNKNOWN 21 UNKNOWN 22 UNKNOWN 23 UNKNOWN 24 UNKNOWN 25 UNKNOWN 26 UNKNOWN 27 UNKNOWN 28 UNKNOWN 29 UNKNOWN 30 UNKNOWN 31 UNKNOWN 32 UNKNOWN 33 UNKNOWN 34 UNKNOWN 35 UNKNOWN 36 UNKNOWN 37 UNKNOWN 38 UNKNOWN 39 UNKNOWN 40 UNKNOWN IV4E00 AUG 27, 2020 11:34 AM FASTRIP 347 2698 OSWELL ST BAKERSFIELD 93306 661-872-8721 EVR/ISD SETUP TYPE: VACUUM ASSIST VACUUM ASSIST TYPE: HEALY VAC IV4F00 AUG 27, 2020 11:34 AM FASTRIP 347 2698 OSWELL ST BAKERSFIELD 93306 661-872-8721 NOZZLE A/L RANGE A/L RATIO: 0.95 - 1.15 IV4000 AUG 27, 2020 11:34 AM FASTRIP 347 2698 OSWELL ST BAKERSFIELD 93306 661-872-8721 VAPOR PROCESSOR TYPE NONE IV4700 AUG 27, 2020 11:34 AM FASTRIP 347 2698 OSWELL ST BAKERSFIELD 93306 661-872-8721 ASSESSMENT TIME START TIME: 10:00 AM TIME DELAY MINUTES: 1 IV5200 AUG 27, 2020 11:34 AM FASTRIP 347 2698 OSWELL ST BAKERSFIELD 93306 661-872-8721 ACCEPT HIGH ORVR: NO IV4A00 AUG 27, 2020 11:34 AM FASTRIP 347 2698 OSWELL ST BAKERSFIELD 93306 661-872-8721 ISD HOSE TABLE HOSE FP FP AFM HOSE ID ID LABEL ID LABEL 01 01 01 01 BLEND3 02 02 02 01 BLEND3 03 03 03 02 BLEND3 04 04 04 02 BLEND3 05 05 05 03 BLEND3 06 06 06 03 BLEND3 07 07 07 04 BLEND3 08 08 08 04 BLEND3 IV4B00 AUG 27, 2020 11:34 AM FASTRIP 347 2698 OSWELL ST BAKERSFIELD 93306 661-872-8721 PRODUCT/HOSE MAP TABLE FP AFID M1/H1 M2/H2 M3/H3 M4/H4 01 01 02/01 03/01 09/01 xx/xx 02 01 02/02 03/02 09/02 xx/xx 03 02 02/03 03/03 09/03 xx/xx 04 02 02/04 03/04 09/04 xx/xx 05 03 02/05 03/05 09/05 xx/xx 06 03 02/06 03/06 09/06 xx/xx 07 04 02/07 03/07 09/07 xx/xx 08 04 02/08 03/08 09/08 xx/xx IV4900 AUG 27, 2020 11:34 AM FASTRIP 347 2698 OSWELL ST BAKERSFIELD 93306 661-872-8721 LABEL TABLE ID LABEL 01 UNASSIGNED 02 BLEND3 03 REGULAR 04 MID GRADE 05 PREMIUM 06 GOLD 07 BRONZE 08 SILVER 09 BLEND2 10 BLEND4 IV1000 AUG 27, 2020 11:34 AM ISD VERSION: 01.03 Jaco 3347 Alarm History Responses Received: I10200 AUG 27, 2020 11:35 AM FASTRIP 347 2698 OSWELL ST BAKERSFIELD 93306 661-872-8721 SYSTEM CONFIGURATION SLOT BOARD TYPE POWER ON RESET CURRENT 1 8SMARTSENSOR BD 39999 39558 2 4 PROBE / G.T. 164016 163029 3 INTERSTITIAL BD 202660 201592 4 INTERSTITIAL BD 201742 200979 5 UNUSED 4995371 4928238 6 UNUSED 4979090 4925032 7 UNUSED 4978325 4923063 8 UNUSED 4971404 4924278 9 STP SENSE BOARD 33199 33137 10 RELAY BOARD 14965 14986 11 RELAY BOARD 14945 14923 12 UNUSED 4975339 4927416 13 UNUSED 4970546 4924001 14 UNUSED 4971331 4923247 15 UNUSED 4970153 4925866 16 UNUSED 4969843 4922178 COMM 1 ELEC DISP INT. 100658 100456 COMM 2 RS232 SERIAL BD 14945 14944 COMM 3 RS232 SERIAL BD 15007 15007 COMM 4 UNUSED 4972447 4926180 COMM 5 UNUSED 4969347 4922158 COMM 6 UNUSED 4967653 4923268 I90200 AUG 27, 2020 11:35 AM SOFTWARE REVISION LEVEL VERSION 330.01 SOFTWARE# 346330-100-B CREATED - 10.07.23.17.25 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD I11100 AUG 27, 2020 11:35 AM FASTRIP 347 2698 OSWELL ST BAKERSFIELD 93306 661-872-8721 PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME T 4 TANK UNL 2 OVERFILL ALARM CLEAR 8-12-20 1:57AM T 4 TANK UNL 2 OVERFILL ALARM ALARM 8-12-20 1:50AM L11 DISP PAN DISP 5-6 FUEL ALARM CLEAR 8-05-20 12:55PM L11 DISP PAN DISP 5-6 FUEL ALARM ALARM 8-05-20 12:53PM L11 DISP PAN DISP 5-6 FUEL ALARM CLEAR 8-05-20 12:44PM L11 DISP PAN DISP 5-6 FUEL ALARM ALARM 8-05-20 12:42PM L 8 ANNULAR UNL 2 ANN SENSOR OUT ALARM CLEAR 8-05-20 12:23PM L 4 ANNULAR DSL ANN SENSOR OUT ALARM CLEAR 8-05-20 12:23PM L 7 STP SUMP UNL 2 STP SENSOR OUT ALARM CLEAR 8-05-20 12:23PM L 3 STP SUMP DSL STP SENSOR OUT ALARM CLEAR 8-05-20 12:23PM L 6 ANNULAR PNL ANN SENSOR OUT ALARM CLEAR 8-05-20 12:23PM L15 STP SUMP PNL STP SENSOR OUT ALARM CLEAR 8-05-20 12:23PM L 2 ANNULAR UNL 1 ANN SENSOR OUT ALARM CLEAR 8-05-20 12:23PM L14 PIPE TRANS SUMP SO SENSOR OUT ALARM CLEAR 8-05-20 12:23PM L 9 DISP PAN DISP 1-2 SENSOR OUT ALARM CLEAR 8-05-20 12:23PM L 1 STP SUMP UNL 1 STP SENSOR OUT ALARM CLEAR 8-05-20 12:23PM L12 DISP PAN DISP 7-8 SENSOR OUT ALARM CLEAR 8-05-20 12:23PM L13 PIPE TRANS SUMP NO SENSOR OUT ALARM CLEAR 8-05-20 12:23PM L11 DISP PAN DISP 5-6 SENSOR OUT ALARM CLEAR 8-05-20 12:23PM L10 DISP PAN DISP 3-4 SENSOR OUT ALARM CLEAR 8-05-20 12:23PM L 4 ANNULAR DSL ANN SENSOR OUT ALARM ALARM 8-05-20 12:22PM L 3 STP SUMP DSL STP SENSOR OUT ALARM ALARM 8-05-20 12:22PM L 2 ANNULAR UNL 1 ANN SENSOR OUT ALARM ALARM 8-05-20 12:22PM L 7 STP SUMP UNL 2 STP SENSOR OUT ALARM ALARM 8-05-20 12:22PM L 8 ANNULAR UNL 2 ANN SENSOR OUT ALARM ALARM 8-05-20 12:22PM L 1 STP SUMP UNL 1 STP SENSOR OUT ALARM ALARM 8-05-20 12:22PM L12 DISP PAN DISP 7-8 SENSOR OUT ALARM ALARM 8-05-20 12:22PM L 6 ANNULAR PNL ANN SENSOR OUT ALARM ALARM 8-05-20 12:22PM L11 DISP PAN DISP 5-6 SENSOR OUT ALARM ALARM 8-05-20 12:22PM L10 DISP PAN DISP 3-4 SENSOR OUT ALARM ALARM 8-05-20 12:22PM L15 STP SUMP PNL STP SENSOR OUT ALARM ALARM 8-05-20 12:22PM L 9 DISP PAN DISP 1-2 SENSOR OUT ALARM ALARM 8-05-20 12:22PM L14 PIPE TRANS SUMP SO SENSOR OUT ALARM ALARM 8-05-20 12:22PM L13 PIPE TRANS SUMP NO SENSOR OUT ALARM ALARM 8-05-20 12:22PM L10 DISP PAN DISP 3-4 FUEL ALARM CLEAR 8-05-20 12:14PM L10 DISP PAN DISP 3-4 FUEL ALARM ALARM 8-05-20 12:13PM L14 PIPE TRANS SUMP SO FUEL ALARM CLEAR 8-05-20 12:13PM L14 PIPE TRANS SUMP SO FUEL ALARM ALARM 8-05-20 12:12PM L 9 DISP PAN DISP 1-2 FUEL ALARM CLEAR 8-05-20 12:12PM L 9 DISP PAN DISP 1-2 FUEL ALARM ALARM 8-05-20 12:12PM L11 DISP PAN DISP 5-6 FUEL ALARM CLEAR 8-05-20 12:11PM L11 DISP PAN DISP 5-6 FUEL ALARM ALARM 8-05-20 12:11PM L13 PIPE TRANS SUMP NO FUEL ALARM CLEAR 8-05-20 12:10PM L13 PIPE TRANS SUMP NO FUEL ALARM ALARM 8-05-20 12:10PM L12 DISP PAN DISP 7-8 FUEL ALARM CLEAR 8-05-20 12:09PM L12 DISP PAN DISP 7-8 FUEL ALARM ALARM 8-05-20 12:09PM L 6 ANNULAR PNL ANN FUEL ALARM CLEAR 8-05-20 12:07PM L 6 ANNULAR PNL ANN FUEL ALARM ALARM 8-05-20 12:07PM L15 STP SUMP PNL STP FUEL ALARM CLEAR 8-05-20 12:07PM L15 STP SUMP PNL STP FUEL ALARM ALARM 8-05-20 12:07PM I11200 AUG 27, 2020 11:35 AM FASTRIP 347 2698 OSWELL ST BAKERSFIELD 93306 661-872-8721 NON-PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME SYSTEM PRINTER ERROR CLEAR 8-11-20 9:02AM SYSTEM PRINTER ERROR ALARM 8-11-20 9:00AM SYSTEM PRINTER ERROR CLEAR 8-08-20 11:32PM SYSTEM PRINTER ERROR ALARM 8-08-20 11:32PM SYSTEM PRINTER ERROR CLEAR 8-08-20 11:31PM SYSTEM PRINTER ERROR ALARM 8-08-20 11:31PM SYSTEM PRINTER ERROR CLEAR 7-24-20 6:01AM SYSTEM PAPER OUT CLEAR 7-24-20 6:01AM SYSTEM PRINTER ERROR ALARM 7-24-20 6:00AM SYSTEM PAPER OUT ALARM 7-24-20 6:00AM SYSTEM PRINTER ERROR CLEAR 7-06-20 1:58AM SYSTEM PRINTER ERROR ALARM 7-06-20 1:57AM SYSTEM PRINTER ERROR CLEAR 6-04-20 12:17PM SYSTEM PAPER OUT CLEAR 6-04-20 12:17PM SYSTEM PRINTER ERROR ALARM 6-04-20 12:16PM SYSTEM PAPER OUT ALARM 6-04-20 12:16PM SYSTEM PRINTER ERROR CLEAR 5-19-20 12:13PM SYSTEM PRINTER ERROR ALARM 5-19-20 12:13PM SYSTEM PAPER OUT CLEAR 5-19-20 12:13PM SYSTEM PAPER OUT ALARM 5-19-20 12:12PM OTHER ISD GROSS PRES WARN CLEAR 5-18-20 11:58AM OTHER ISD GROSS PRES WARN ALARM 5-16-20 10:01AM OTHER ISD VAPOR LEAK WARN CLEAR 5-15-20 4:22PM OTHER ISD VAPOR LEAK WARN ALARM 5-15-20 10:01AM SYSTEM PRINTER ERROR CLEAR 5-04-20 12:47AM SYSTEM PAPER OUT CLEAR 5-04-20 12:47AM SYSTEM PRINTER ERROR ALARM 5-04-20 12:47AM SYSTEM PRINTER ERROR CLEAR 5-04-20 12:47AM SYSTEM PRINTER ERROR ALARM 5-04-20 12:47AM SYSTEM PRINTER ERROR CLEAR 5-04-20 12:47AM SYSTEM PRINTER ERROR ALARM 5-04-20 12:46AM SYSTEM PAPER OUT ALARM 5-04-20 12:46AM SYSTEM PRINTER ERROR CLEAR 3-23-20 2:36PM SYSTEM PRINTER ERROR ALARM 3-23-20 2:35PM SYSTEM PRINTER ERROR CLEAR 3-22-20 6:39PM SYSTEM PRINTER ERROR ALARM 3-22-20 6:39PM SYSTEM PRINTER ERROR CLEAR 3-15-20 11:33AM SYSTEM PAPER OUT CLEAR 3-15-20 11:33AM SYSTEM PRINTER ERROR ALARM 3-15-20 11:32AM SYSTEM PAPER OUT ALARM 3-15-20 11:32AM SYSTEM PRINTER ERROR CLEAR 3-15-20 11:32AM SYSTEM PAPER OUT CLEAR 3-15-20 11:32AM SYSTEM PRINTER ERROR ALARM 3-15-20 11:32AM SYSTEM PAPER OUT ALARM 3-15-20 11:32AM SYSTEM PRINTER ERROR CLEAR 2-27-20 9:55AM SYSTEM PAPER OUT CLEAR 2-27-20 9:55AM SYSTEM PAPER OUT ALARM 2-27-20 9:55AM SYSTEM PRINTER ERROR ALARM 2-27-20 9:55AM SYSTEM PRINTER ERROR CLEAR 1-30-20 1:35AM SYSTEM PRINTER ERROR ALARM 1-30-20 1:35AM I20600 AUG 27, 2020 11:35 AM FASTRIP 347 2698 OSWELL ST BAKERSFIELD 93306 661-872-8721 TANK ALARM HISTORY TANK 1 UNL 1 SETUP DATA WARNING JUL 30, 2014 9:29 AM OVERFILL ALARM JUN 7, 2020 1:36 AM MAR 20, 2020 2:14 AM MAR 11, 2020 4:43 AM LOW PRODUCT ALARM AUG 17, 2018 11:12 PM AUG 16, 2018 6:33 PM AUG 13, 2018 4:09 PM SUDDEN LOSS ALARM AUG 2, 2018 9:07 AM JUL 26, 2018 9:56 AM AUG 3, 2017 9:15 AM HIGH PRODUCT ALARM JUL 28, 2017 10:25 AM AUG 10, 2015 10:06 AM AUG 5, 2014 10:12 AM INVALID FUEL LEVEL AUG 18, 2018 7:34 AM AUG 17, 2018 2:04 AM AUG 10, 2015 10:04 AM PROBE OUT AUG 2, 2018 9:41 AM AUG 2, 2018 9:07 AM JUL 26, 2018 10:06 AM DELIVERY NEEDED AUG 17, 2018 11:12 PM AUG 16, 2018 6:33 PM AUG 13, 2018 4:09 PM LOW TEMP WARNING AUG 2, 2018 9:42 AM JUL 26, 2018 10:07 AM AUG 3, 2017 10:20 AM TANK 2 DIESEL SETUP DATA WARNING JUL 30, 2014 9:30 AM OVERFILL ALARM JUL 26, 2018 10:07 AM AUG 3, 2017 9:43 AM AUG 4, 2016 9:40 AM LOW PRODUCT ALARM JUL 27, 2016 8:49 AM FEB 22, 2016 11:02 AM FEB 1, 2016 3:47 PM HIGH PRODUCT ALARM AUG 2, 2018 9:42 AM JUL 26, 2018 10:07 AM AUG 3, 2017 9:43 AM INVALID FUEL LEVEL JUL 26, 2018 10:08 AM AUG 4, 2016 8:40 AM DEC 13, 2015 10:28 AM PROBE OUT AUG 2, 2018 9:42 AM AUG 2, 2018 9:06 AM JUL 26, 2018 10:08 AM HIGH WATER WARNING JUL 26, 2018 10:06 AM DELIVERY NEEDED JUL 27, 2016 8:49 AM FEB 22, 2016 11:01 AM FEB 1, 2016 3:46 PM LOW TEMP WARNING AUG 3, 2017 10:18 AM AUG 5, 2015 10:10 AM AUG 5, 2014 10:18 AM TANK 3 PNL SETUP DATA WARNING JUL 30, 2014 9:31 AM OVERFILL ALARM SEP 4, 2018 1:48 AM JUL 26, 2018 10:09 AM AUG 3, 2017 9:45 AM LOW PRODUCT ALARM APR 27, 2016 7:12 PM FEB 20, 2016 5:19 PM AUG 30, 2013 4:50 AM SUDDEN LOSS ALARM JUL 5, 2019 8:14 PM AUG 2, 2018 9:05 AM JUL 26, 2018 9:58 AM HIGH PRODUCT ALARM AUG 2, 2018 9:44 AM JUL 28, 2017 10:27 AM AUG 10, 2015 10:23 AM INVALID FUEL LEVEL FEB 21, 2016 4:15 PM AUG 5, 2015 10:13 AM AUG 11, 2011 9:26 AM PROBE OUT DEC 11, 2018 11:42 AM DEC 11, 2018 11:41 AM DEC 11, 2018 11:37 AM DELIVERY NEEDED APR 27, 2016 7:03 PM FEB 20, 2016 5:19 PM AUG 30, 2013 4:49 AM LOW TEMP WARNING AUG 3, 2017 10:17 AM AUG 10, 2015 10:14 AM AUG 5, 2014 10:20 AM TANK 4 UNL 2 SETUP DATA WARNING JUL 30, 2014 9:32 AM OVERFILL ALARM AUG 12, 2020 1:50 AM JUL 8, 2020 4:09 PM JUN 28, 2020 12:55 PM LOW PRODUCT ALARM JUL 28, 2017 10:00 AM JUL 27, 2016 8:47 AM AUG 10, 2015 10:08 AM SUDDEN LOSS ALARM AUG 2, 2018 9:07 AM JUL 26, 2018 9:56 AM AUG 3, 2017 9:15 AM HIGH PRODUCT ALARM AUG 2, 2018 9:40 AM JUL 28, 2017 10:22 AM OCT 15, 2016 5:24 AM INVALID FUEL LEVEL JUL 27, 2016 8:47 AM JUL 31, 2013 10:09 AM JUL 31, 2013 9:18 AM PROBE OUT JUL 5, 2019 8:16 PM JUL 5, 2019 8:15 PM AUG 2, 2018 9:40 AM DELIVERY NEEDED JUL 28, 2017 10:00 AM JUL 27, 2016 8:47 AM AUG 10, 2015 10:08 AM LOW TEMP WARNING JUL 5, 2019 8:17 PM JUL 26, 2018 10:05 AM JUL 28, 2017 10:23 AM I38200 AUG 27, 2020 11:35 AM I30200 AUG 27, 2020 11:35 AM FASTRIP 347 2698 OSWELL ST BAKERSFIELD 93306 661-872-8721 LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 UNL 1 STP AUG 5, 2020 12:22 PM SENSOR OUT ALARM AUG 5, 2020 12:03 PM FUEL ALARM AUG 27, 2019 9:59 AM SENSOR OUT ALARM 2 UNL 1 ANN AUG 5, 2020 12:22 PM SENSOR OUT ALARM AUG 5, 2020 12:06 PM FUEL ALARM AUG 27, 2019 9:59 AM SENSOR OUT ALARM 3 DSL STP AUG 5, 2020 12:22 PM SENSOR OUT ALARM AUG 5, 2020 12:05 PM FUEL ALARM AUG 27, 2019 9:59 AM SENSOR OUT ALARM 4 DSL ANN AUG 5, 2020 12:22 PM SENSOR OUT ALARM AUG 5, 2020 12:06 PM FUEL ALARM AUG 27, 2019 9:59 AM SENSOR OUT ALARM 6 PNL ANN AUG 5, 2020 12:22 PM SENSOR OUT ALARM AUG 5, 2020 12:07 PM FUEL ALARM AUG 27, 2019 9:59 AM SENSOR OUT ALARM 7 UNL 2 STP AUG 5, 2020 12:22 PM SENSOR OUT ALARM AUG 5, 2020 11:59 AM FUEL ALARM JUL 9, 2020 5:16 PM FUEL ALARM 8 UNL 2 ANN AUG 5, 2020 12:22 PM SENSOR OUT ALARM AUG 5, 2020 12:05 PM FUEL ALARM AUG 27, 2019 9:59 AM SENSOR OUT ALARM 9 DISP 1-2 AUG 5, 2020 12:22 PM SENSOR OUT ALARM AUG 5, 2020 12:12 PM FUEL ALARM AUG 27, 2019 9:59 AM SENSOR OUT ALARM 10 DISP 3-4 AUG 5, 2020 12:22 PM SENSOR OUT ALARM AUG 5, 2020 12:13 PM FUEL ALARM AUG 27, 2019 9:59 AM SENSOR OUT ALARM 11 DISP 5-6 AUG 5, 2020 12:53 PM FUEL ALARM AUG 5, 2020 12:42 PM FUEL ALARM AUG 5, 2020 12:22 PM SENSOR OUT ALARM 12 DISP 7-8 AUG 5, 2020 12:22 PM SENSOR OUT ALARM AUG 5, 2020 12:09 PM FUEL ALARM AUG 27, 2019 9:59 AM SENSOR OUT ALARM 13 TRANS SUMP NO AUG 5, 2020 12:22 PM SENSOR OUT ALARM AUG 5, 2020 12:10 PM FUEL ALARM AUG 27, 2019 10:09 AM FUEL ALARM 14 TRANS SUMP SO AUG 5, 2020 12:22 PM SENSOR OUT ALARM AUG 5, 2020 12:12 PM FUEL ALARM AUG 27, 2019 10:10 AM FUEL ALARM 15 PNL STP AUG 5, 2020 12:22 PM SENSOR OUT ALARM AUG 5, 2020 12:07 PM FUEL ALARM AUG 27, 2019 9:59 AM SENSOR OUT ALARM I31600 AUG 27, 2020 11:36 AM FASTRIP 347 2698 OSWELL ST BAKERSFIELD 93306 661-872-8721 SMART SENSOR ALARM HISTORY REPORT SENSOR LOCATION 1 PS 3-4 2 FM 1-2 3 FM 3-4 4 FM 5-6 5 FM 7-8 I40200 AUG 27, 2020 11:36 AM I40300 AUG 27, 2020 11:36 AM I34200 AUG 27, 2020 11:36 AM I34700 AUG 27, 2020 11:36 AM IV0100 AUG 27, 2020 11:36 AM FASTRIP 347 2698 OSWELL ST BAKERSFIELD 93306 661-872-8721 ISD ALARM STATUS REPORT EVR TYPE: VACUUM ASSIST ISD TYPE: 01.03 VAPOR PROCESSOR TYPE: NONE OVERALL STATUS :PASS EVR VAPOR COLLECTION :PASS EVR VAPOR CONTAINMENT :PASS ISD MONITOR UP-TIME :100% EVR/ISD PASS TIME :100% WARNING ALARMS DATE TIME DESCRIPTION READING VALUE 20-05-18 10:01:17 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 5.00 20-05-17 10:01:12 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 5.00 20-05-16 10:01:09 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 5.00 20-05-15 10:01:09 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 12.87 20-01-27 10:01:47 A/L RATIO GROSS BLOCKAGE FP 6 BLEND3 BLKD 19-12-22 10:01:57 A/L RATIO GROSS BLOCKAGE FP 6 BLEND3 BLKD 19-12-16 10:02:01 A/L RATIO DEGRADATION FP 4 BLEND3 0.79 19-12-15 10:01:55 A/L RATIO DEGRADATION FP 4 BLEND3 0.79 19-12-14 10:01:57 A/L RATIO GROSS BLOCKAGE FP 6 BLEND3 BLKD 19-12-14 10:01:57 A/L RATIO DEGRADATION FP 4 BLEND3 0.79 FAILURE ALARMS DATE TIME DESCRIPTION READING VALUE 15-12-16 10:01:58 A/L RATIO GROSS BLOCKAGE FP 8 BLEND3 BLKD 15-12-16 10:01:58 A/L RATIO GROSS BLOCKAGE FP 7 BLEND3 BLKD 15-12-15 10:01:56 A/L RATIO GROSS BLOCKAGE FP 8 BLEND3 BLKD 12-08-18 10:02:49 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 2.70 11-08-25 10:02:34 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 2.05 SHUTDOWN & MISCELLANEOUS EVENTS DATE TIME DESCRIPTION ACTION/NAME 20-08-06 10:02:31 READINESS ISD:PP EVR:PP ISD & EVR READY 20-08-05 12:34:48 READINESS ISD:PP EVR:NN EVR READINESS PENDING 20-08-05 12:34:48 ISD STARTUP 20-08-05 12:33:55 ISD SHUTDOWN 20-05-18 11:58:26 CONTAINMENT GROSS & DEGRD TEST MANUALLY CLEARED 20-05-15 16:22:48 CONTAINMENT VAPOR LEAKAGE TEST MANUALLY CLEARED 20-03-26 10:01:09 READINESS ISD:PP EVR:PP ISD & EVR READY 20-03-26 09:55:38 READINESS ISD:PP EVR:NN EVR READINESS PENDING 20-03-26 09:55:38 ISD STARTUP 20-03-26 09:55:30 ISD SHUTDOWN Jaco 3347 Alarm History After Responses Received: I10200 AUG 27, 2020 2:05 PM FASTRIP 347 2698 OSWELL ST BAKERSFIELD 93306 661-872-8721 SYSTEM CONFIGURATION SLOT BOARD TYPE POWER ON RESET CURRENT 1 8SMARTSENSOR BD 39999 39636 2 4 PROBE / G.T. 164016 163379 3 INTERSTITIAL BD 202660 202153 4 INTERSTITIAL BD 201742 201625 5 UNUSED 4995371 4930618 6 UNUSED 4979090 4928736 7 UNUSED 4978325 4926579 8 UNUSED 4971404 4926558 9 STP SENSE BOARD 33199 33209 10 RELAY BOARD 14965 14993 11 RELAY BOARD 14945 14950 12 UNUSED 4975339 4929969 13 UNUSED 4970546 4924027 14 UNUSED 4971331 4928975 15 UNUSED 4970153 4929356 16 UNUSED 4969843 4926353 COMM 1 ELEC DISP INT. 100658 100821 COMM 2 RS232 SERIAL BD 14945 14971 COMM 3 RS232 SERIAL BD 15007 15035 COMM 4 UNUSED 4972447 4929441 COMM 5 UNUSED 4969347 4927410 COMM 6 UNUSED 4967653 4929504 I90200 AUG 27, 2020 2:06 PM SOFTWARE REVISION LEVEL VERSION 330.01 SOFTWARE# 346330-100-B CREATED - 10.07.23.17.25 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD I11100 AUG 27, 2020 2:06 PM FASTRIP 347 2698 OSWELL ST BAKERSFIELD 93306 661-872-8721 PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME T 3 TANK PNL PROBE OUT CLEAR 8-27-20 12:45PM T 2 TANK DIESEL PROBE OUT CLEAR 8-27-20 12:44PM T 3 TANK PNL OVERFILL ALARM CLEAR 8-27-20 12:36PM T 3 TANK PNL PROBE OUT ALARM 8-27-20 12:36PM T 3 TANK PNL OVERFILL ALARM ALARM 8-27-20 12:35PM T 3 TANK PNL PROBE OUT CLEAR 8-27-20 12:34PM T 3 TANK PNL PROBE OUT ALARM 8-27-20 12:34PM T 2 TANK DIESEL OVERFILL ALARM CLEAR 8-27-20 12:32PM T 2 TANK DIESEL PROBE OUT ALARM 8-27-20 12:32PM T 2 TANK DIESEL OVERFILL ALARM ALARM 8-27-20 12:32PM T 2 TANK DIESEL PROBE OUT CLEAR 8-27-20 12:31PM T 2 TANK DIESEL PROBE OUT ALARM 8-27-20 12:27PM T 1 TANK UNL 1 PROBE OUT CLEAR 8-27-20 12:26PM T 1 TANK UNL 1 OVERFILL ALARM CLEAR 8-27-20 12:24PM T 1 TANK UNL 1 PROBE OUT ALARM 8-27-20 12:24PM T 1 TANK UNL 1 OVERFILL ALARM ALARM 8-27-20 12:24PM T 1 TANK UNL 1 PROBE OUT CLEAR 8-27-20 12:20PM T 1 TANK UNL 1 PROBE OUT ALARM 8-27-20 12:19PM T 4 TANK UNL 2 PROBE OUT CLEAR 8-27-20 12:18PM T 4 TANK UNL 2 OVERFILL ALARM CLEAR 8-27-20 12:17PM T 4 TANK UNL 2 PROBE OUT ALARM 8-27-20 12:17PM T 4 TANK UNL 2 OVERFILL ALARM ALARM 8-27-20 12:16PM T 4 TANK UNL 2 PROBE OUT CLEAR 8-27-20 12:16PM T 4 TANK UNL 2 PROBE OUT ALARM 8-27-20 12:15PM L 6 ANNULAR PNL ANN SENSOR OUT ALARM CLEAR 8-27-20 12:13PM L 4 ANNULAR DSL ANN SENSOR OUT ALARM CLEAR 8-27-20 12:13PM L 3 STP SUMP DSL STP SENSOR OUT ALARM CLEAR 8-27-20 12:13PM L 8 ANNULAR UNL 2 ANN SENSOR OUT ALARM CLEAR 8-27-20 12:13PM L 7 STP SUMP UNL 2 STP SENSOR OUT ALARM CLEAR 8-27-20 12:13PM L 2 ANNULAR UNL 1 ANN SENSOR OUT ALARM CLEAR 8-27-20 12:13PM L15 STP SUMP PNL STP SENSOR OUT ALARM CLEAR 8-27-20 12:13PM L14 PIPE TRANS SUMP SO SENSOR OUT ALARM CLEAR 8-27-20 12:13PM L12 DISP PAN DISP 7-8 SENSOR OUT ALARM CLEAR 8-27-20 12:13PM L11 DISP PAN DISP 5-6 SENSOR OUT ALARM CLEAR 8-27-20 12:13PM L10 DISP PAN DISP 3-4 SENSOR OUT ALARM CLEAR 8-27-20 12:13PM L 1 STP SUMP UNL 1 STP SENSOR OUT ALARM CLEAR 8-27-20 12:13PM L13 PIPE TRANS SUMP NO SENSOR OUT ALARM CLEAR 8-27-20 12:13PM L 9 DISP PAN DISP 1-2 SENSOR OUT ALARM CLEAR 8-27-20 12:13PM L15 STP SUMP PNL STP SENSOR OUT ALARM ALARM 8-27-20 12:13PM L14 PIPE TRANS SUMP SO SENSOR OUT ALARM ALARM 8-27-20 12:12PM L12 DISP PAN DISP 7-8 SENSOR OUT ALARM ALARM 8-27-20 12:12PM L11 DISP PAN DISP 5-6 SENSOR OUT ALARM ALARM 8-27-20 12:12PM L 4 ANNULAR DSL ANN SENSOR OUT ALARM ALARM 8-27-20 12:12PM L 3 STP SUMP DSL STP SENSOR OUT ALARM ALARM 8-27-20 12:12PM L10 DISP PAN DISP 3-4 SENSOR OUT ALARM ALARM 8-27-20 12:12PM L 2 ANNULAR UNL 1 ANN SENSOR OUT ALARM ALARM 8-27-20 12:12PM L13 PIPE TRANS SUMP NO SENSOR OUT ALARM ALARM 8-27-20 12:12PM L 8 ANNULAR UNL 2 ANN SENSOR OUT ALARM ALARM 8-27-20 12:12PM L 7 STP SUMP UNL 2 STP SENSOR OUT ALARM ALARM 8-27-20 12:12PM L 6 ANNULAR PNL ANN SENSOR OUT ALARM ALARM 8-27-20 12:12PM I11200 AUG 27, 2020 2:06 PM FASTRIP 347 2698 OSWELL ST BAKERSFIELD 93306 661-872-8721 NON-PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME T 2 TANK DIESEL LOW TEMP WARNING CLEAR 8-27-20 12:44PM T 2 TANK DIESEL LOW TEMP WARNING ALARM 8-27-20 12:44PM T 1 TANK UNL 1 LOW TEMP WARNING CLEAR 8-27-20 12:27PM T 1 TANK UNL 1 LOW TEMP WARNING ALARM 8-27-20 12:26PM SYSTEM PRINTER ERROR CLEAR 8-11-20 9:02AM SYSTEM PRINTER ERROR ALARM 8-11-20 9:00AM SYSTEM PRINTER ERROR CLEAR 8-08-20 11:32PM SYSTEM PRINTER ERROR ALARM 8-08-20 11:32PM SYSTEM PRINTER ERROR CLEAR 8-08-20 11:31PM SYSTEM PRINTER ERROR ALARM 8-08-20 11:31PM SYSTEM PRINTER ERROR CLEAR 7-24-20 6:01AM SYSTEM PAPER OUT CLEAR 7-24-20 6:01AM SYSTEM PRINTER ERROR ALARM 7-24-20 6:00AM SYSTEM PAPER OUT ALARM 7-24-20 6:00AM SYSTEM PRINTER ERROR CLEAR 7-06-20 1:58AM SYSTEM PRINTER ERROR ALARM 7-06-20 1:57AM SYSTEM PRINTER ERROR CLEAR 6-04-20 12:17PM SYSTEM PAPER OUT CLEAR 6-04-20 12:17PM SYSTEM PRINTER ERROR ALARM 6-04-20 12:16PM SYSTEM PAPER OUT ALARM 6-04-20 12:16PM SYSTEM PRINTER ERROR CLEAR 5-19-20 12:13PM SYSTEM PRINTER ERROR ALARM 5-19-20 12:13PM SYSTEM PAPER OUT CLEAR 5-19-20 12:13PM SYSTEM PAPER OUT ALARM 5-19-20 12:12PM OTHER ISD GROSS PRES WARN CLEAR 5-18-20 11:58AM OTHER ISD GROSS PRES WARN ALARM 5-16-20 10:01AM OTHER ISD VAPOR LEAK WARN CLEAR 5-15-20 4:22PM OTHER ISD VAPOR LEAK WARN ALARM 5-15-20 10:01AM SYSTEM PRINTER ERROR CLEAR 5-04-20 12:47AM SYSTEM PAPER OUT CLEAR 5-04-20 12:47AM SYSTEM PRINTER ERROR ALARM 5-04-20 12:47AM SYSTEM PRINTER ERROR CLEAR 5-04-20 12:47AM SYSTEM PRINTER ERROR ALARM 5-04-20 12:47AM SYSTEM PRINTER ERROR CLEAR 5-04-20 12:47AM SYSTEM PRINTER ERROR ALARM 5-04-20 12:46AM SYSTEM PAPER OUT ALARM 5-04-20 12:46AM SYSTEM PRINTER ERROR CLEAR 3-23-20 2:36PM SYSTEM PRINTER ERROR ALARM 3-23-20 2:35PM SYSTEM PRINTER ERROR CLEAR 3-22-20 6:39PM SYSTEM PRINTER ERROR ALARM 3-22-20 6:39PM SYSTEM PRINTER ERROR CLEAR 3-15-20 11:33AM SYSTEM PAPER OUT CLEAR 3-15-20 11:33AM SYSTEM PRINTER ERROR ALARM 3-15-20 11:32AM SYSTEM PAPER OUT ALARM 3-15-20 11:32AM SYSTEM PRINTER ERROR CLEAR 3-15-20 11:32AM SYSTEM PAPER OUT CLEAR 3-15-20 11:32AM SYSTEM PRINTER ERROR ALARM 3-15-20 11:32AM SYSTEM PAPER OUT ALARM 3-15-20 11:32AM SYSTEM PRINTER ERROR CLEAR 2-27-20 9:55AM SYSTEM PAPER OUT CLEAR 2-27-20 9:55AM I20600 AUG 27, 2020 2:06 PM FASTRIP 347 2698 OSWELL ST BAKERSFIELD 93306 661-872-8721 TANK ALARM HISTORY TANK 1 UNL 1 SETUP DATA WARNING JUL 30, 2014 9:29 AM OVERFILL ALARM AUG 27, 2020 12:24 PM JUN 7, 2020 1:36 AM MAR 20, 2020 2:14 AM LOW PRODUCT ALARM AUG 17, 2018 11:12 PM AUG 16, 2018 6:33 PM AUG 13, 2018 4:09 PM SUDDEN LOSS ALARM AUG 2, 2018 9:07 AM JUL 26, 2018 9:56 AM AUG 3, 2017 9:15 AM HIGH PRODUCT ALARM JUL 28, 2017 10:25 AM AUG 10, 2015 10:06 AM AUG 5, 2014 10:12 AM INVALID FUEL LEVEL AUG 18, 2018 7:34 AM AUG 17, 2018 2:04 AM AUG 10, 2015 10:04 AM PROBE OUT AUG 27, 2020 12:24 PM AUG 27, 2020 12:19 PM AUG 2, 2018 9:41 AM DELIVERY NEEDED AUG 17, 2018 11:12 PM AUG 16, 2018 6:33 PM AUG 13, 2018 4:09 PM LOW TEMP WARNING AUG 27, 2020 12:26 PM AUG 2, 2018 9:42 AM JUL 26, 2018 10:07 AM TANK 2 DIESEL SETUP DATA WARNING JUL 30, 2014 9:30 AM OVERFILL ALARM AUG 27, 2020 12:32 PM JUL 26, 2018 10:07 AM AUG 3, 2017 9:43 AM LOW PRODUCT ALARM JUL 27, 2016 8:49 AM FEB 22, 2016 11:02 AM FEB 1, 2016 3:47 PM HIGH PRODUCT ALARM AUG 2, 2018 9:42 AM JUL 26, 2018 10:07 AM AUG 3, 2017 9:43 AM INVALID FUEL LEVEL JUL 26, 2018 10:08 AM AUG 4, 2016 8:40 AM DEC 13, 2015 10:28 AM PROBE OUT AUG 27, 2020 12:32 PM AUG 27, 2020 12:27 PM AUG 2, 2018 9:42 AM HIGH WATER WARNING JUL 26, 2018 10:06 AM DELIVERY NEEDED JUL 27, 2016 8:49 AM FEB 22, 2016 11:01 AM FEB 1, 2016 3:46 PM LOW TEMP WARNING AUG 27, 2020 12:44 PM AUG 3, 2017 10:18 AM AUG 5, 2015 10:10 AM TANK 3 PNL SETUP DATA WARNING JUL 30, 2014 9:31 AM OVERFILL ALARM AUG 27, 2020 12:35 PM SEP 4, 2018 1:48 AM JUL 26, 2018 10:09 AM LOW PRODUCT ALARM APR 27, 2016 7:12 PM FEB 20, 2016 5:19 PM AUG 30, 2013 4:50 AM SUDDEN LOSS ALARM JUL 5, 2019 8:14 PM AUG 2, 2018 9:05 AM JUL 26, 2018 9:58 AM HIGH PRODUCT ALARM AUG 2, 2018 9:44 AM JUL 28, 2017 10:27 AM AUG 10, 2015 10:23 AM INVALID FUEL LEVEL FEB 21, 2016 4:15 PM AUG 5, 2015 10:13 AM AUG 11, 2011 9:26 AM PROBE OUT AUG 27, 2020 12:36 PM AUG 27, 2020 12:34 PM DEC 11, 2018 11:42 AM DELIVERY NEEDED APR 27, 2016 7:03 PM FEB 20, 2016 5:19 PM AUG 30, 2013 4:49 AM LOW TEMP WARNING AUG 3, 2017 10:17 AM AUG 10, 2015 10:14 AM AUG 5, 2014 10:20 AM TANK 4 UNL 2 SETUP DATA WARNING JUL 30, 2014 9:32 AM OVERFILL ALARM AUG 27, 2020 12:16 PM AUG 12, 2020 1:50 AM JUL 8, 2020 4:09 PM LOW PRODUCT ALARM JUL 28, 2017 10:00 AM JUL 27, 2016 8:47 AM AUG 10, 2015 10:08 AM SUDDEN LOSS ALARM AUG 2, 2018 9:07 AM JUL 26, 2018 9:56 AM AUG 3, 2017 9:15 AM HIGH PRODUCT ALARM AUG 2, 2018 9:40 AM JUL 28, 2017 10:22 AM OCT 15, 2016 5:24 AM INVALID FUEL LEVEL JUL 27, 2016 8:47 AM JUL 31, 2013 10:09 AM JUL 31, 2013 9:18 AM PROBE OUT AUG 27, 2020 12:17 PM AUG 27, 2020 12:15 PM JUL 5, 2019 8:16 PM DELIVERY NEEDED JUL 28, 2017 10:00 AM JUL 27, 2016 8:47 AM AUG 10, 2015 10:08 AM LOW TEMP WARNING JUL 5, 2019 8:17 PM JUL 26, 2018 10:05 AM JUL 28, 2017 10:23 AM I38200 AUG 27, 2020 2:06 PM I30200 AUG 27, 2020 2:06 PM FASTRIP 347 2698 OSWELL ST BAKERSFIELD 93306 661-872-8721 LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 UNL 1 STP AUG 27, 2020 12:12 PM SENSOR OUT ALARM AUG 27, 2020 12:01 PM FUEL ALARM AUG 5, 2020 12:22 PM SENSOR OUT ALARM 2 UNL 1 ANN AUG 27, 2020 12:12 PM SENSOR OUT ALARM AUG 27, 2020 11:55 AM FUEL ALARM AUG 5, 2020 12:22 PM SENSOR OUT ALARM 3 DSL STP AUG 27, 2020 12:12 PM SENSOR OUT ALARM AUG 27, 2020 12:02 PM FUEL ALARM AUG 5, 2020 12:22 PM SENSOR OUT ALARM 4 DSL ANN AUG 27, 2020 12:12 PM SENSOR OUT ALARM AUG 27, 2020 11:57 AM FUEL ALARM AUG 5, 2020 12:22 PM SENSOR OUT ALARM 6 PNL ANN AUG 27, 2020 12:12 PM SENSOR OUT ALARM AUG 27, 2020 11:57 AM FUEL ALARM AUG 5, 2020 12:22 PM SENSOR OUT ALARM 7 UNL 2 STP AUG 27, 2020 12:12 PM SENSOR OUT ALARM AUG 27, 2020 12:00 PM FUEL ALARM AUG 5, 2020 12:22 PM SENSOR OUT ALARM 8 UNL 2 ANN AUG 27, 2020 12:12 PM SENSOR OUT ALARM AUG 27, 2020 11:55 AM FUEL ALARM AUG 5, 2020 12:22 PM SENSOR OUT ALARM 9 DISP 1-2 AUG 27, 2020 12:12 PM SENSOR OUT ALARM AUG 27, 2020 12:08 PM FUEL ALARM AUG 5, 2020 12:22 PM SENSOR OUT ALARM 10 DISP 3-4 AUG 27, 2020 12:12 PM SENSOR OUT ALARM AUG 27, 2020 12:09 PM FUEL ALARM AUG 5, 2020 12:22 PM SENSOR OUT ALARM 11 DISP 5-6 AUG 27, 2020 12:12 PM SENSOR OUT ALARM AUG 27, 2020 12:06 PM FUEL ALARM AUG 5, 2020 12:53 PM FUEL ALARM 12 DISP 7-8 AUG 27, 2020 12:12 PM SENSOR OUT ALARM AUG 27, 2020 12:04 PM FUEL ALARM AUG 5, 2020 12:22 PM SENSOR OUT ALARM 13 TRANS SUMP NO AUG 27, 2020 12:12 PM SENSOR OUT ALARM AUG 27, 2020 12:10 PM FUEL ALARM AUG 5, 2020 12:22 PM SENSOR OUT ALARM 14 TRANS SUMP SO AUG 27, 2020 12:12 PM SENSOR OUT ALARM AUG 27, 2020 12:09 PM FUEL ALARM AUG 5, 2020 12:22 PM SENSOR OUT ALARM 15 PNL STP AUG 27, 2020 12:13 PM SENSOR OUT ALARM AUG 27, 2020 12:03 PM FUEL ALARM AUG 5, 2020 12:22 PM SENSOR OUT ALARM I31600 AUG 27, 2020 2:06 PM FASTRIP 347 2698 OSWELL ST BAKERSFIELD 93306 661-872-8721 SMART SENSOR ALARM HISTORY REPORT SENSOR LOCATION 1 PS 3-4 2 FM 1-2 3 FM 3-4 4 FM 5-6 5 FM 7-8 I40200 AUG 27, 2020 2:06 PM I40300 AUG 27, 2020 2:06 PM I34200 AUG 27, 2020 2:06 PM I34700 AUG 27, 2020 2:06 PM IV0100 AUG 27, 2020 2:06 PM FASTRIP 347 2698 OSWELL ST BAKERSFIELD 93306 661-872-8721 ISD ALARM STATUS REPORT EVR TYPE: VACUUM ASSIST ISD TYPE: 01.03 VAPOR PROCESSOR TYPE: NONE OVERALL STATUS :PASS EVR VAPOR COLLECTION :PASS EVR VAPOR CONTAINMENT :PASS ISD MONITOR UP-TIME :100% EVR/ISD PASS TIME :100% WARNING ALARMS DATE TIME DESCRIPTION READING VALUE 20-05-18 10:01:17 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 5.00 20-05-17 10:01:12 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 5.00 20-05-16 10:01:09 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 5.00 20-05-15 10:01:09 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 12.87 20-01-27 10:01:47 A/L RATIO GROSS BLOCKAGE FP 6 BLEND3 BLKD 19-12-22 10:01:57 A/L RATIO GROSS BLOCKAGE FP 6 BLEND3 BLKD 19-12-16 10:02:01 A/L RATIO DEGRADATION FP 4 BLEND3 0.79 19-12-15 10:01:55 A/L RATIO DEGRADATION FP 4 BLEND3 0.79 19-12-14 10:01:57 A/L RATIO GROSS BLOCKAGE FP 6 BLEND3 BLKD 19-12-14 10:01:57 A/L RATIO DEGRADATION FP 4 BLEND3 0.79 FAILURE ALARMS DATE TIME DESCRIPTION READING VALUE 15-12-16 10:01:58 A/L RATIO GROSS BLOCKAGE FP 8 BLEND3 BLKD 15-12-16 10:01:58 A/L RATIO GROSS BLOCKAGE FP 7 BLEND3 BLKD 15-12-15 10:01:56 A/L RATIO GROSS BLOCKAGE FP 8 BLEND3 BLKD 12-08-18 10:02:49 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 2.70 11-08-25 10:02:34 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 2.05 SHUTDOWN & MISCELLANEOUS EVENTS DATE TIME DESCRIPTION ACTION/NAME 20-08-27 12:11:57 READINESS ISD:PP EVR:NN EVR READINESS PENDING 20-08-27 12:11:57 ISD STARTUP 20-08-27 12:11:39 ISD SHUTDOWN 20-08-06 10:02:31 READINESS ISD:PP EVR:PP ISD & EVR READY 20-08-05 12:34:48 READINESS ISD:PP EVR:NN EVR READINESS PENDING 20-08-05 12:34:48 ISD STARTUP 20-08-05 12:33:55 ISD SHUTDOWN 20-05-18 11:58:26 CONTAINMENT GROSS & DEGRD TEST MANUALLY CLEARED 20-05-15 16:22:48 CONTAINMENT VAPOR LEAKAGE TEST MANUALLY CLEARED 20-03-26 10:01:09 READINESS ISD:PP EVR:PP ISD & EVR READY &(56 &DOLIRUQLD(QYLURQPHQWDO5HSRUWLQJ6\VWHP,' ,GHQWLILFDWLRQ867 8QGHUJURXQG6WRUDJH7DQN,&& ,QWHUQDWLRQDO&RGH&RXQFLO 81 ZZZXQLGRFVRUJ5HY 81'(5*5281'6725$*(7$1. 63,//&217$,1(57(67,1*5(3257)250 3DJHRI  7\SHRI$FWLRQ,QVWDOODWLRQ7HVW5HSDLU7HVW0RQWK7HVW , )$&,/,7<,1)250$7,21 &(56,''DWHRI6SLOO&RQWDLQHU7HVW %XVLQHVV1DPH(Same as Facility Name or DBA-Doing Business As) %XVLQHVV6LWH$GGUHVV &LW\ =,3&RGH ,, 81'(5*5281'6725$*(7$1.6(59,&(7(&+1,&,$1,1)250$7,21 1DPHRI8676HUYLFH7HFKQLFLDQ3HUIRUPLQJWKH7HVW(Print as shown on the ICC Certification.) 3KRQH &RQWUDFWRU7DQN7HVWHU/LFHQVH ,&&&HUWLILFDWLRQ ,&&&HUWLILFDWLRQ([SLUDWLRQ'DWH 6SLOO&RQWDLQHU7HVWLQJ7UDLQLQJDQG&HUWLILFDWLRQV(List applicable certifications.) ,,, 63,//&217$,1(57(67,1*,1)250$7,21 7HVW0HWKRG8VHG0DQXIDFWXUHU*XLGHOLQHV(Specify) ,QGXVWU\&RGHRU(QJLQHHULQJ6WDQGDUG (Specify) (QJLQHHUHG0HWKRG(Specify) Attach the testing procedures and all documentation required to determine the results.RI$WWDFKHG3DJHV 7$1.,'(By tank number, stored product, etc.) 6SLOO&RQWDLQHU0DQXIDFWXUHU 0HWKRGRI&DWKRGLF3URWHFWLRQ1RQ0HWDOOLF1RQ0HWDOOLF1RQ0HWDOOLF1RQ0HWDOOLF ,VRODWLRQ,VRODWLRQ,VRODWLRQ,VRODWLRQ 2WKHU(Specify in V.)2WKHU(Specify in V.)2WKHU(Specify in V.)2WKHU(Specify in V.) ,QVLGH'LDPHWHURI6SLOO&RQWDLQHU(Inches) 'HSWKRI6SLOO&RQWDLQHU(Inches) 'RHVWKHVSLOOFRQWDLQHUKDYHDJDOORQFDSDFLW\"<HV1R<HV1R<HV1R<HV1R 0HWKRGWR.HHS6SLOO&RQWDLQHU(PSW\'UDLQ9DOYH'UDLQ9DOYH'UDLQ9DOYH'UDLQ9DOYH 2QVLWH3XPS2QVLWH3XPS2QVLWH3XPS2QVLWH3XPS 2WKHU(Specify in V.)2WKHU(Specify in V.)2WKHU(Specify in V.)2WKHU(Specify in V.) ,9 6800$5<2)7(67,1*5(68/76 6SLOO&RQWDLQHU7HVW5HVXOWV3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLO 9 &200(176 Any items marked “Fail” above must be explained in this section. Any additional comments may also be provided here. 9, &(57,),&$7,21%<8676(59,&(7(&+1,&,$1&21'8&7,1*7+,67(67,1* ,KHUHE\FHUWLI\WKDWWKHVSLOOFRQWDLQHUVZHUHWHVWHGLQDFFRUGDQFHZLWK&DOLIRUQLD&RGHRI5HJXODWLRQV7LWOH'LYLVLRQ &KDSWHU6HFWLRQDQGDOOWKHLQIRUPDWLRQFRQWDLQHGKHUHLQLVDFFXUDWH 8676HUYLFH7HFKQLFLDQ6LJQDWXUH If the facility has more components than this form accommodates, additional copies of this page may be attached. Bakersfield 93306 804904 8485827 8/16/2022 FFS 1010993708 PEI 1200 T1 Unl OPW 11.00” 12.50” T2 Unl Slave OPW 11.00” 12.50” T3 Prem OPW 11.00” 12.50” T4 DSL OPW 11.00” 12.50” Aaron Perrigo (800) 339-9930 10023037 8/27/2020 Jaco #3347 Fastrip #26 2698 Oswell Street