HomeMy WebLinkAboutCUPA REPORT 10-9-2020BAKERSFIELD FIRE DEPARTMENT
Underground Storage Tank Program Prevention Services Division2101 H Street
DW Inspection Repot Bakersfield, CA 93301
Permission to Inspect: _ Phone: 661-326-3979
0 Fax: 661-852-2171
Business Name: AT&T California - SA098
15-021-103811 II Date -10/9/2020
H R S F I D
FIRE
.A R rte'. T
.I&I ad
Address Name: 3221 S H St Bakersfield, CA 93304 CAT080020514 I, Inspector Name: Peter Armagost #8856813
Inspection Type: Routine Report . Final
NVO = No Violation Observed OUT = Out of Compliance NA = Not Applicable UD = Undetermined
COS = Corrected On Site RPT = Repeat Violation
Violation
Program Requirement
° o
SOC
Comments
N o
D
a�
>O
Z
O
Q
Z
o
D
O
U
a
�o
0
File Review
Facility Tank Information
2030021
Facility has a valid Permit
Tank 1-6016- DSI -DW
to Operate from the
®
❑
❑
❑
❑
❑
None
CUPA - 23 CCR 16 2712(i);
HSC 6.7 25284
2010010
UST Operating Permit
Application for Facility
information and Tank
information
®
❑
❑
❑
❑
❑
None
submitted/maintained - 23
CCR 16 2711; HSC 6.7
25286(x)
2010001
Current BOE number
submitted to the CUPA
®
1:1
❑
❑
❑
❑
None
and/or CERS - HSC 6.7
25286(c)
2030011
UST compliance
statement and/or
Designated Operator
®
❑
❑
❑
❑
❑
None
current certification
submitted - 23 CCR 16
2715(x), 2715(b
2030046
A complete and accurate
response plan has been
submitted, approved and
®
❑
El
❑
❑
❑
None
maintained - 23 CCR 16
2632, 2634(e), 2641(h),
2712(1)
2030041
A complete and accurate
plot plan has been
submitted, approved and
®
❑
❑
❑
❑
❑
Minor
maintained - 23 CCR 16
2632(d) (1) (C), 2711(a)(8)
2010006
Owner/Operator has not
made false statements or
representation on any
®
❑
❑
❑
❑
❑
None
required document - HSC
6.7 25299
2010003
Owner/Operator has a
DO and/or informed the
CUPA of any change (s)
®
❑
❑
❑
❑
❑
None
within 30 days - 23 CCR
16 2715(x)
Testing
Violation
Program, Requir'em ent
0 0
SOC
Comments
No
0
>
a
0
a.
z
0
z
D
0
Woj
2030002
Owner/Operator has
tested and certified leak
M
F-1
[_1
None
detection equipment
annually - 23 CCR 16 2638
2030048
Secondary containment
testing conducted every
36 months in accordance
M
F-1
F]
1-1
None
with requirements - 23
CCR 16 2637
2030055
Spill buckets have been
tested annually as
0
D
El
F-1
F]
D
None
re ed -HSC 6.7 25284.2
2010009
Secondary containment
test results submitted to
the CUPA within 30 days
M
F-1
M
D
F]
D
None
after the test - 23 CCR 16
2637(e)
2030064
COPA was poperly
notified within the
prescribed number of
1:1
F-1
R
R
R
None
hours prior to testing - 23
CCR 16 2637(o, 2638(e),
2643(g), 2644.1(a)(4)
Install/Repair
2060009
Permits obtained to
install, replace, repair, or
None
modify part of the UST
m - 23 CCR 16 2712
UST System Observation
General Monitoring
2030003
Leak detection system
maintains continuous
RD
monitoring that activates
None
❑
an audible and visual
Yes
alarm - 23 CCR 16 2632)
2634;2636,2666
2030016
The annular space of the
tank, piping and sumps
are continuously
RD
monitored and activates
None
❑
the alarm - 23 CCR 16
Yes
2631(g), 2632(c)(2)(A)&(8),
2633(c), 2636(o
2030017
Product piping outside the
UDC is fail-safe and shuts
down the pump or
None
restricts flow - 23 CCR 16
2636(0(5)
2030018
Turbine sump monitor
activates an audible and
RD
visual alarm or stops the
1:1
F-1
D
E]
F]
None
F-1
flow of at the dispenser -
Yes
23 CCR 16 2636 1)
Underground Storage Tank Program - DW Inspection Report v 2.0
Violation
ProgramRequirement:
0 o
SOC
Comments
NoU)
>
D
a
0
(L
0) 0
z
0
z
>
2030019
Monitoring system in the
UDCs activates an
audible and visual alarm
H
F-1
F-1
F1
1-1
F -I
None
or stops the flow at the
UDC -23 CCR 16
2636 (0(1)
2030043
Leak detection equipment
properly programmed or
RD
properly operated - 23
N
F-1
1-1
F1
F-1
F]
None
M
CCR 16 2632, 2634, 2636,
Yes
2666
2060005
System constructed with
a monitoring system
capable of detecting entry
Z
F-1
�
F-1
�
F-]
None
into secondary
containment -HSC 6.7
25291 (b)
2060014
Correct leak detection
equipment installed for
RD
the type of system
M
�
�
1:1
El
F-1
None
F-1
present - 23 CCR 16 2638;
Yes
HSC 6.7 25290.11 25290.2)
25291
2060015
Sensor located in the
RD
proper position/location -
N
F]
F-1
El
1:1
F]
None
F-1
23 CCR 16 2630(d), 2641(a)
Yes
2030062
Facility is in compliance
with not tampering with or
RD
disabling leak detection
Z
F-1
M
F-1
F-1
F]
None
R
devices or alarms -HSC
Yes
6.7 25299(a)(9)
2060022
System constructed with
a monitoring system
capable of detecting entry
N
F-�
F-�
F-]
F-�
F-]
None
into secondary
containment -HSC 6.7
25290.2(d)
2030034
Tag/sticker on affixed
monitoring equipment
being certified, repaired,
N
F-1
El
F-1
1:1❑
None
or replaced - 23 CCR 16
2638(o
VPH Monitoring VPH
2030065
Interstitial monitoring of
the annular spaces of the
RD
UST is properly
F-1
El
N
El
F-1
F]
None
F-1
maintained -HSC 6.7
Yes
25290.1 (e)
2060023
System constructed with
a monitoring system
capable of detecting entry
into secondary
F-1
1-1
N
F-1
F-1
F]
None
containment -HSC 6.7
25290.1(d)
Underground Storage Tank Program - DW Inspection Report v 2.0
Violation
Program Requirement
4-
0
.2
SOC
Comments
No
0
(1)
Z
0
Z
0
0.2
>
Line Leak
Detector
2060012
Line leak detector
installed on pressurized
RD
piping system -HSC 6.7
F1
F-1
Z
�
F-1
�
None
F-1
25290. 1 (h), 25290.2(g),
25291(o, 25292(e),
Yes
2636(0(2)
2030026
Line leak detectors detect
a 3 gph leak and/or
RD
audible and ViSU21 alarm
M
F-1
MF
-1
F-1
F]
None
M
function properly - 23
CCR 16 26360(6),
Yes
2666(c)
2030027
Turbine shuts down when
a leak is detected or
RD
when line leak detector is
1-1
F-1
Z
F-1
F-1
F❑
None
F1
disconnected - 23 CCR 16
Yes
2666(c)
2030025
Pressurized piping able to
detect a 3.0 gph leak
RD
within an hour, and
F-1
F-1
Z
R
R
R
None
R
restricts the flow or
Yes
alarms - 23 CCR 16
2636(0(2)
Secondary Containment
2060010
UST storing a hazardous
RD
substance has secondary
R
R
None
R
containment -HSC 6.7
Yes
25292
Underground Storage Tank Program - DW Inspection Report v 2.0
Violation
Program Requirement
0 .2
SOC
Comments
No
0
O>
a.oZ
0
ZW
>
2030008
UDC, sumps, and/or
other secondary
containment in good
0
�
F-1
M
�
F-1
None
condition and/or are free
of debris/liquid -HSC 6.7
25290.11 25290.21 25291
2030040
Secondarily contained
RD
piping maintained to allow
Z
F-]
F-]
F-]
F-1
None
1-1
liquid to drain into sump -
Yes
23 CCR 16 2630(d), 2641 (a)
2060006
Secondary containment
piping slopes back to the
Z
1-1
F-1
1:1
F-1
F]
None
collection sump - 23 CCR
16 263(c)
2030047
Secondary containment
maintained tight and has
been confirmed by testing
�
�
�
�
F-1
None
- 23 CCR 16 2662; HSC 6.7
25290.1(c)(2), 25290.2(c)(2),
25291 (a), 25292(e)
2030060
Entry fittings in secondary
containment for UST
system maintained
Z
�
1:1
F-1
�
None
tight/sealed - 23 CCR 16
2630, 2635(d), 2636(c)l
2666
2060020
Spill bucket is installed
and has a functional drain
RP
valve or other means to
Z
F-1
1-1
F-1
M
F❑
None
❑
remove liquid - 23 CCR 16
Yes
2635(b), 2665
2030054
Spill bucket maintained in
RP
good condition and free of
M
F-1
1-1
F]
None
F-1
debris and/or liquid - 23
Yes
CCR 16 2635(b), 2715(c)(2)
2060019
Spill bucket to has a
minimum capacity of five
Z
F]
El
F-1
None'
gallons - 23 CCR 16
2635(b), 2665
Overfill
2030035
UST system is operated
to prevent unauthorized
RP
release, including spills
Z
M
F-1
F-1
❑
M
None
F-1
and overfills -HSC 6.7
Yes
25292.1 (a)
2030036
Overfill prevention system
has not been overridden
RID
and meets overfill
Z
F1
El
F-1
F-1
F
None
F]
requirements - 23 CCR 16
Yes
2635 b)(2), 2665
Underground Storage Tank Program - DW Inspection Report v 2.0
Z:�
Violation
Program Requirement
4 -
0
SOC
Comments
No
0
>'
F-
D
ci
Cl)
0
a.
0)0
z
0
z
D
0
>
On Site Records
Certifications
2030023
Required designated
operators or contractors
maintain a proper and
M
D
F-1
1-1
❑
1--]
None
current ICC certification -
23 CCR 16 2715
2030024
Service technician,
installer, and/ or
employee maintain a
N
F-1
1-1
1-1
F-1
F-1
None
proper license - 23 CCR
162715
2030031
Employee or contractor
obtained and maintained
proper manufacturer
M
F-1
F-1
F-1
❑
F]
None
certification - 23 CCR 16
2715
2010007
Submit/maintain current
Certificate of Financial
Responsibility/mechanism
of financial assurance -
M
F-1
F�
F-1
F-1
F�
None
23 CCR 16 2711; 23 CCR
18 2808.11 2809-2809.2;
HSC 6.7 25292.2; HSC
6.75 25299.30-25299.34
Designated Operator
2010004
Copies of DO inspections
for last 12 months and list
of trained employees
N
D
❑
F1
M
F]
None
maintained - 23 CCR 16
2715
2030013
Designated operator
properly conducted the
monthly inspection and
N
F-1
❑
1-1
El❑
None
the reports are complete -
23 CCR 16 2715
2030010
DO notified operator of
any condition observed
during the monthly
M
F-1
F-1
El
F-1
F]
None
inspection that may
require action - 23 CCR 16
2715(d)
2030012
DO employee training
performed, current for at
least one employee on
N
F-1
F-1
F-1
None
site, and a log kept - 23
CCR 16 2715(c)(6), 2715(o
Underground Storage Tank Program - DW Inspection Report v 2.0
Violation
Program Requirement
0 .2
(1)
soc
Comments
No
0
>
:D
<
a
C/)
0
0.
d.) 1;
Z
Z
0
Z
M
0
W
>
Logs
2030001
Leak detection alarm
logs, maintenance and
RD
records of appropriate
M
F-1
F-1
F-1
F-1
F -I
None
F-1
follow-up actions
Yes
maintained - 23 CCR 16
26321 2634, 2712(b)
Maintenance/Tests
2010008
Monitoring, maintenance,
repairs, linings, and
RD
upgrade records
Z
1-1
F-1
F-1
F-1
F]
None
F-1
maintained for the proper
Yes
time period - 23 CCR 16
2712(b)
Documentation
2030033
Failure to maintain on site
an approved monitoring
Z
1:1
F-1
F-1
1-1
F]
None
plan - 23 CCR 16 26322
2634) 27111 2712(1)
2030037
Written agreement
between the tank owner
and tank operator to
monitor the tank system
Z
F]
1-1
F-1
M
❑
None
is maintained - 23 CCR 16
2620(b); HSC 6.7
25284(a)(3)
2030061
Suspected or actual
unauthorized release
RD
reported in appropriate
F-1
F-1
Z
F-1
F-1
F]
None
F-1
time frame -HSC 6.7
Yes
29294, 29295
General Operating Requirements
Permit Condition/Approval
2030039
Compliance with all
operating permit
0
F-1
F-1
F-1
F-1
F -I
None
conditions - 23 CCR 16
2712; HSC 6.7 25299
2030059
UST system maintained
in accordance with
exclusion/exemption
Z
F-1
F-1
1:1
F-1
F❑
None
status -HSC 6.7 25281.61
25283.5
2030014
Owner/Operator received
approval and has
implemented a training
F]
F-1
Z
F-1
El
F]
None
program at an unstaffed
facility - 23 CCR 16
2715(0(2)
2030015
Facility exhibited that the
method used to monitor
the tank meets the
monitoring methods in
Z
M
F-1
F]
1:1
F]
None
2643(f) - 23 CCR 16 2643
Underground Storage Tank Program - DW Inspection Report v 2.0
Violation
Program Requirement
0 02
SOC
Comments
No
0,
OD
CL
0)0
0
zD
L)
W
Red Tag
2030045
Red Tag information is
legible and has not been
F-1
F-1
N
FIR
R
None
tampered with - 23 CCR
16 2 717. 1 (g)
2030044
Facility did not allow for
deposit of petroleum into
a UST that has a red tag
None
affixed to the fill - 23 CCR
16 2717.1
Install/Repair
2060024
UST system is made of or
lined with materials that
are compatible with the
None
substance stored - 23
CCR 16 2631.1
2060021
Striker plate installed and
positioned correctly - 23
None
A
CCR 16 2631 (c), 2662(d)
® There were no violations noted for this inspection.
❑This report shall serve as a "NOTICE TO COMPLY" for Minor Violations, and a "NOTICE OF VIOLATION" for
Major violations. You are, hereby, ordered to correct the above noted violations within 30 days, or according to
correction summaries provided. Formal enforcement and/or penalty assessment may be initiated for any
violations noted, and for those not corrected in a timely manner. (NOTE: If this is a preliminary report, a final report
will follow.) /I
Inspectors Signature: Date: 1l2,aZO
Inspector: Enter # of Violations: RD: RP:
Check one box for facility Significant Operational Status (SOC) to be reported to SWRCB and US EPA:
F-1 SOC with both Release Detection and Release Detection (Facility has no Release Prevention and no Release
Prevention Violations)
F-1 Not in SOC (Facility has both Release Prevention and Release Detection Violations)
❑SOC with Release Detection only (Facility has no Release Detection violations but one or more Release
Prevention violations)
❑ SOC with Release Prevention only (Facility has no Release Prevention violations but one or more Release
Detection violations)
Underground Storage Tank Program - DW Inspection Report v 2.0