Loading...
HomeMy WebLinkAboutFMC - 4012 WHITE LN 10-19-2020IMPACT VALVE LEAK DETECTOR MONITOR CERTIFICATION SPILL BUCKET TEST 11000 N. MoPac Expressway, Suite 500 Austin, Texas 78759 Phone: (512) 451-6334 Fax: (512) 459-1459 Date Printed and Mailed: 10/20/2020 BAKERSFIELD FIRE DEPARTMENT OFFICE OF ENVIRONMENTAL SERVICES INSPECTOR KRIS KARNS 1501 TRUXTUN AVE. BAKERSFIELD, CA 93301 Test Date: 10/19/2020 Order Number: 3451481 Dear Regulator, Enclosed are the results of recent testing performed at the following facility: 7-ELEVEN #22150 4012 WHITE LN BAKERSFIELD, CA 93309 In an effort to keep all our record keeping and reporting requirements as current as possible, Tanknology kindly requests you notify Dawn Kohlmeyer in writing at dkohlmeyer@tanknology.com when your CUPA requires all records to be submitted electronically via the CERS database. Your assistance in this endeavor is greatly appreciated. Testing performed: Sincerely, Dawn Kohlmeyer Manager, Field Reporting LDT 5000 Field Test Apparatus Line Leak Detector Test Page 1 of 1 Work Order:3451481 Date:10/19/2020 Site Name / ID:7-ELEVEN #22150 / 22150 Address:4012 WHITE LN City:BAKERSFIELD State:CA Zip:93309 Tank ID Product Product Line Tested From Existing/New Mechanical/Electronic Manufacturer/Model Serial No. Pump Operating Pressure (psi) Calibrated Leak (ml/min) Calibrated Leak (gph) Holding PSI *N/A for Electronic LD's Resiliency (ml) *N/A for Electronic LD's Metering PSI *N/A for Electronic LD's Opening Time (sec) *N/A for Electronic LD's Test Results T1 87 UNLEADED 1 3 Existing Mechanical Vaporless LD-2000 XXXX 28.00 189.0 3.00 26.00 125.00 16 7 Pass T2 91 PREMIUM 1 3 Existing Mechanical Vaporless LD-2000 XXXX 33.00 189.0 3.00 30.00 75.00 18 6 Pass T3 DSL Diesel 1 3 Existing Mechanical Vaporless LD-2000 XXXX 30.00 189.0 3.00 28.00 175.00 18 8 Pass Technician Comments: Technician Name:Luis Navarro Certification #:147337 Technician Signature:Expire Date:11/27/2021 Environmental Compliance for Petroleum Systems © 2020 Tanknology Inc., Austin, TX. All rights reserved. tanknology.com Impact Valve Inspection Impact Valve Operational Inspection Work Order:3451481 Date:10/19/2020 Site Name/ID:7-ELEVEN #22150 Address:4012 WHITE LN City:BAKERSFIELD State:CA Zip:93309 How Inspected: Line Test NFPA 30A PEI RP1200 Other Dispenser Number Grade Secure Mount? Valve Lock?Pass/ Fail Comments 1/2 87 Pass Fail Not Tested 1/2 91 Pass Fail Not Tested 3/4 40 Pass Fail Not Tested 3/4 87 Pass Fail Not Tested 3/4 91 Pass Fail Not Tested 5/6 87 Pass Fail Not Tested 5/6 91 Pass Fail Not Tested 7/8 87 Pass Fail Not Tested 7/8 91 Pass Fail Not Tested 9/10 87 Pass Fail Not Tested 9/10 91 Pass Fail Not Tested 11/12 40 Pass Fail Not Tested 11/12 87 Pass Fail Not Tested 11/12 91 Pass Fail Not Tested Technician Comments: Technician Name:Luis Navarro Signature: Environmental Compliance for Petroleum Systems ©2020 Tanknology Inc., Austin, TX. All rights reserved. tanknology.com SWRCB, January 2006 Spill Bucket Testing Report Form This form is intended for use by contractors performing annual testing of UST spill containment structures. The completed form and printouts from tests (if applicable), should be provided to the facility owner/operator for submittal to the local regulatory agency. 1. FACILITY INFORMATION Facility Name: 7-ELEVEN #22150 Date of Testing: 10/19/2020 Facility Address: 4012 WHITE LN , BAKERSFIELD, CA 93309 Facility Contact: MANAGER Phone: 661-834-8565 Date Local Agency Was Notified of Testing: 9/16/2020 Name of Local Agency Inspector (if present during testing): Peter Armagost, Fire Department 2. TESTING CONTRACTOR INFORMATION Company Name: TANKNOLOGY INC. Technician Conducting Test: Luis Navarro Credentials1: CSLB Contractor ICC Service Tech. SWRCB Tank Tester Other (Specify) License Number(s): 743160 / 8171123 3. SPILL BUCKET TESTING INFORMATION Test Method Used By: Hydrostatic Vacuum Other Test Equipment Used: LAKE TEST Equipment Resolution: 0.0625 in. Identify Spill Bucket (By Tank Number, Stored Product, etc.) Bucket Installation Type: Bucket Diameter: Bucket Depth: Wait time between applying vacuum/water and start of test Test Start Time (TI): Initial Reading (RI): Test End Time(TF): Final Reading (RF): Test Duration(TF–TI): Change in Reading (RF–RI) : Pass/Fail Threshold or Criteria: Test Result: Spill Box # Tank T1 87 UNLEADED - Fill 1 - Direct - Below Grade in containment sump Direct Bury Contained in Sump 12.00 14.50 15 min 09:00:00 10.30 in. H20 10:00:00 10.30 in. H20 1 hr 0.00 in. H20 +/- 0.00 Pass Spill Box # Tank T2 91 PREMIUM - Fill 1 - Direct - Below Grade in containment sump Direct Bury Contained in Sump 12.00 14.50 15 min 09:00:00 10.30 in. H20 10:00:00 10.30 in. H20 1 hr 0.00 in. H20 +/- 0.00 Pass Spill Box # Tank T3 DSL Diesel - Fill 1 - Direct - Grade level in containment sump Direct Bury Contained in Sump 12.00 14.50 15 min 09:00:00 10.30 in. H20 10:00:00 10.30 in. H20 1 hr 0.00 in. H20 +/- 0.00 Pass Spill Box # Direct Bury Contained in Sump min +/- Comments - (include information on repairs made prior to testing, and recommended follow-up for failed tests) CERTIFICATION OF TECHNICIAN RESPONSIBLE FOR CONDUCTING THIS TESTING I hereby certify that all the information contained in this report is true, accurate, and in full compliance with legal requirements. Technician's Signature:Date:10/19/2020 1State laws and regulations do not currently require testing to be performed by a qualified contractor. However, local requirements may be more stringent. WO: 3451481 Site Diagram (This site diagram is for reference only and is not drawn to scale) Work Order:3451481 Site ID / Name:22150 / 7-ELEVEN #22150 Address:4012 WHITE LN City:BAKERSFIELD State:CA Zip:93309 CERS = California Environmental Reporting System, ID = Identification, ICC = International Code Council Page 1 of 2 TYPE OF ACTION Installation Repair 12 Month 1. FACILITY INFORMATION CERS ID Test Date Facility Name Facility Address City ZIP Code 2. SERVICE TECHNICIAN INFORMATION Company Performing the Test Phone Mailing Address Service Technician Performing Test Contractor/Tank Tester License Number ICC Number ICC Expiration Date 3. TRAINING AND CERTIFICATIONS Manufacturer and Test Equipment Training Certifications Expiration Date 4. TEST PROCEDURE INFORMATION Test Procedures Used Components Tested 5. CERTIFICATION BY SERVICE TECHNICIAN CONDUCTING TEST I hereby certify that each spill container was tested in accordance with California Code of Regulations, title 23, division 3, chapter 16, section 2637.1; that required supporting documentation is attached; and all information contained herein is accurate. I understand that test procedures shall be made available upon request by the governing authority. Service Technician Signature Date Total # of Pages Additional copies of this page may be attached. Page 2 of 2 6. SPILL CONTAINER DETAILS Test Method Developed by Manufacturer Industry Standard Professional Engineer Test Type Pressure Vacuum Hydrostatic Tank ID Spill Container Manufacturer: Method of Cathodic Protection Nonmetallic Other Nonmetallic Other Nonmetallic Other Nonmetallic Other Is the spill container minimum capacity five gallons excluding riser volume? Yes No* Yes No* Yes No* Yes No* Method to keep spill container empty Drain Pump Other Drain Pump Other Drain Pump Other Drain Pump Other Spill Container Test Results Pass Fail Pass Fail Pass Fail Pass Fail Tank ID Spill Container Manufacturer: Method of Cathodic Protection Nonmetallic Other Nonmetallic Other Nonmetallic Other Nonmetallic Other Is the spill container minimum capacity five gallons excluding riser volume? Yes No* Yes No* Yes No* Yes No* Method to keep spill container empty Drain Pump Other Drain Pump Other Drain Pump Other Drain Pump Other Spill Container Test Results Pass Fail Pass Fail Pass Fail Pass Fail 1 8. COMMENTS Describe all answers marked “Other,” “No,” or “Fail” and each proposed remedy. * Mark here if: Spill containers do not have a minimum capacity of five gallons and require replacement. CERS = California Environmental Reporting System, GPH = Gallons Per Hour, ID = Identification, ICC = International Code Council, LLD = Line Leak Detector, NA = Not Applicable, SW = Single- Walled, UDC = Under-Dispenser Containment, UST = Underground Storage Tank, VPH = Vacuum/Pressure/Hydrostatic Page 1 of 6 TYPE OF ACTION Installation Repair 12 Month 1. FACILITY INFORMATION CERS ID Certification Date Facility Name Facility Address City ZIP Code 2. SERVICE TECHNICIAN INFORMATION Company Performing the Certification Phone Mailing Address Service Technician Performing Test Contractor/Tank Tester License Number ICC Number ICC Expiration Date 3. TRAINING AND CERTIFICATIONS Manufacturer and Test Equipment Training Certifications Expiration Date 4. CERTIFICATION BY SERVICE TECHNICIAN CONDUCTING TEST I hereby certify that the monitoring system is operational in accordance with California Code of Regulations, title 23, division 3, chapter 16, section 2638; that required supporting documentation is attached; and all information contained herein is accurate. Service Technician Signature Date Total # of Pages Page 2 of 6 5. MONITORING SYSTEM AND PROGRAMMING A separate Monitoring System Certification Form must be prepared for each control panel. Make of Monitoring System Control Panel Model of Monitoring System Control Panel Software Version Installed Attach the post-certification reports if the monitoring system is capable of generating either;Monitoring System Set-up Alarm History Report Yes No NA All monitoring equipment is operational per manufacturer’s specifications? Secondary containment systems are free of damage, debris, or liquid? Are the audible and visual alarms operational? All sensors have been: 1) visually inspected for wiring kinks, breaks and residual buildup on floats; and 2) tested for functionality and confirmed operational? Are all sensors installed to detect a release at the earliest opportunity in the secondary containment? The monitoring system set-up was reviewed, and proper settings confirmed? Was the monitoring control panel’s backup battery visually inspected, functionally tested, and confirmed operational? Does the flow of fuel stop at the dispenser if a release is detected in the under- dispenser containment? Does the turbine automatically shut down if the piping secondary containment monitoring system fails to operate or is electrically disconnected? Does the turbine automatically shut down if the piping secondary containment monitoring system detects a release? Which sensors initiate positive shut down? (Check all that apply)Sump UDC If monitoring system alarms are relayed to a remote monitoring center, is all communication equipment operational? Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 Page 3 of 6 6. SENSOR TESTING RESULTS List only sensors tested on date of this certification. List “Sensor ID” as labeled in system programming. Additional copies of this page may be attached to accommodate all sensors tested. Sensor ID Sensor Model Component(s) Monitored Pass Fail Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 Page 4 of 6 7. LINE LEAK DETECTOR TESTING Check this box if line leak detectors ARE NOT installed. (Do not complete this section.) Simulated release rate verified: (Check all that apply.) 3 GPH 0.1 GPH 0.2 GPH Yes No NA Has the testing apparatus been properly calibrated? For emergency generator tank systems, does the LLD create an audible and visual alarm when a leak is detected? For mechanical LLDs, does the LLD restrict the flow through the pipe when a release is detected? For electronic LLDs, does the turbine automatically shut off when a release is detected? For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system is disabled or disconnected? For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system malfunctions or fails a tightness test? For electronic LLDs, have all accessible wiring connections been visually inspected for kinks and breaks? Were all items on the equipment manufacturer’s maintenance checklist completed? Were all LLDs confirmed operational within regulatory requirements? LLD ID LLD Model Lines Monitored Pass Fail Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 Page 5 of 6 8. IN-TANK GAUGING TESTING Check this box if tank gauging is used only for inventory control. Check this box if NO tank gauging equipment is installed. (Do not complete this section if either box is checked.) Yes No NA All wiring has been: 1) visually inspected for kinks, breaks and proper entry and termination; and 2) tested for ground faults? Were all in-tank gauging probes visually inspected for damage and residue buildup to ensure that floats move freely, functionally tested, and confirmed operational? Was accuracy of system’s product level readings tested? Was accuracy of system’s water level readings tested? Were all probes reinstalled properly? Were all items on the equipment manufacturer’s maintenance checklist completed? Probe ID Probe Model Tanks Monitored Pass Fail 9. COMMENTS Describe all answers marked “No” or “Fail” and proposed remedy. List all monitoring equipment either replaced or repaired. Page 6 of 6 10. MONITORING SITE PLAN Date site plan was prepared: If a site plan has been prepared that shows all required information, you may include it, rather than this page, with your Monitoring System Certification Form. The site plan must show the general layout of tanks and identify locations of the monitoring panel, and all leak detection equipment and monitoring locations. Include a legend for all symbols depicted. W.O.# SC1-3451481 Site Diagram W.O.# SC1-3451481 Responses Received: I10200 OCT 19, 2020 11:57 AM 177218 7-11 22150 4012 WHITE LN Bakersfield,CA 93309 SYSTEM CONFIGURATION SLOT BOARD TYPE POWER ON RESET CURRENT 1 4 PROBE / G.T. 163767 162745 2 INTERSTITIAL BD 202157 201445 3 INTERSTITIAL BD 201906 201187 4 7SMARTSENSOR BD 507535 506054 5 8SMARTSENSOR BD 39370 39316 6 8SMARTSENSOR BD 39436 39339 7 UNUSED 9630658 9400770 8 UNUSED 9604492 9394718 9 RELAY BOARD 14912 14946 10 STP SENSE BOARD 33066 33037 11 UNUSED 9612236 9400577 12 UNUSED 9593361 9383388 13 UNUSED 9593471 9373241 14 UNUSED 9594938 9383725 15 UNUSED 9587712 9394570 16 UNUSED 9588544 9389845 COMM 1 ELEC DISP INT. 101074 100928 COMM 2 SERIAL SAT BD 9598244 479238 COMM 3 UNUSED 9587668 9394052 COMM 4 UNUSED 9586924 9377156 COMM 5 RS485 SERIAL BD 68405 68378 COMM 6 MT COMM BOARD 407925 408181 I90200 OCT 19, 2020 11:57 AM SOFTWARE REVISION LEVEL VERSION 335.00 SOFTWARE+ACM- 346335-100-A CREATED - 18.08.27.10.22 S-MODULE+ACM- 330160-104-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS BIR ISD/APM I11100 OCT 19, 2020 11:57 AM 177218 7-11 22150 4012 WHITE LN Bakersfield,CA 93309 PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME T 2 TANK 91 PROBE OUT CLEAR 10-19-20 11:45AM T 2 TANK 91 PROBE OUT ALARM 10-19-20 11:43AM T 2 TANK 91 MAX PRODUCT ALARM CLEAR 10-19-20 10:29AM T 2 TANK 91 PROBE OUT CLEAR 10-19-20 10:29AM T 2 TANK 91 OVERFILL ALARM CLEAR 10-19-20 10:27AM T 2 TANK 91 PROBE OUT ALARM 10-19-20 10:27AM T 2 TANK 91 MAX PRODUCT ALARM ALARM 10-19-20 10:26AM T 2 TANK 91 OVERFILL ALARM ALARM 10-19-20 10:26AM T 1 TANK 87 HIGH WATER ALARM CLEAR 10-19-20 10:26AM T 1 TANK 87 MAX PRODUCT ALARM CLEAR 10-19-20 10:23AM T 1 TANK 87 PROBE OUT CLEAR 10-19-20 10:22AM T 1 TANK 87 OVERFILL ALARM CLEAR 10-19-20 10:21AM T 1 TANK 87 PROBE OUT ALARM 10-19-20 10:21AM T 2 TANK 91 HIGH WATER ALARM CLEAR 10-19-20 10:21AM T 1 TANK 87 MAX PRODUCT ALARM ALARM 10-19-20 10:20AM T 1 TANK 87 OVERFILL ALARM ALARM 10-19-20 10:20AM T 3 TANK DSL MAX PRODUCT ALARM CLEAR 10-19-20 10:19AM T 3 TANK DSL PROBE OUT CLEAR 10-19-20 10:19AM T 3 TANK DSL OVERFILL ALARM CLEAR 10-19-20 10:18AM T 3 TANK DSL PROBE OUT ALARM 10-19-20 10:18AM T 3 TANK DSL HIGH WATER ALARM CLEAR 10-19-20 10:18AM T 1 TANK 87 LOW PRODUCT ALARM CLEAR 10-19-20 10:18AM T 2 TANK 91 LOW PRODUCT ALARM CLEAR 10-19-20 10:17AM T 3 TANK DSL MAX PRODUCT ALARM ALARM 10-19-20 10:17AM T 3 TANK DSL OVERFILL ALARM ALARM 10-19-20 10:16AM T 3 TANK DSL LOW PRODUCT ALARM CLEAR 10-19-20 10:14AM T 2 TANK 91 HIGH WATER ALARM ALARM 10-19-20 10:13AM T 1 TANK 87 HIGH WATER ALARM ALARM 10-19-20 10:10AM T 2 TANK 91 LOW PRODUCT ALARM ALARM 10-19-20 10:10AM T 2 TANK 91 PROBE OUT CLEAR 10-19-20 10:09AM T 2 TANK 91 PROBE OUT ALARM 10-19-20 10:08AM T 3 TANK DSL HIGH WATER ALARM ALARM 10-19-20 10:08AM T 1 TANK 87 LOW PRODUCT ALARM ALARM 10-19-20 10:07AM T 1 TANK 87 PROBE OUT CLEAR 10-19-20 10:07AM T 1 TANK 87 PROBE OUT ALARM 10-19-20 10:06AM T 3 TANK DSL LOW PRODUCT ALARM ALARM 10-19-20 10:04AM T 3 TANK DSL PROBE OUT CLEAR 10-19-20 10:04AM T 3 TANK DSL PROBE OUT ALARM 10-19-20 10:03AM L 2 STP SUMP 87 STP SENSOR OUT ALARM CLEAR 10-19-20 9:47AM L 8 PIPE DSL FILL SENSOR OUT ALARM CLEAR 10-19-20 9:47AM L 7 STP SUMP DSL STP SENSOR OUT ALARM CLEAR 10-19-20 9:47AM L 1 ANNULAR 87 ANNULAR SENSOR OUT ALARM CLEAR 10-19-20 9:47AM L 6 PIPE 91 FILL SENSOR OUT ALARM CLEAR 10-19-20 9:47AM L 5 STP SUMP 91 STP SENSOR OUT ALARM CLEAR 10-19-20 9:47AM L 4 ANNULAR DSL-91 ANNULAR SENSOR OUT ALARM CLEAR 10-19-20 9:47AM L 3 PIPE 87 FILL SENSOR OUT ALARM CLEAR 10-19-20 9:47AM L12 DISP PAN UDC 7-8 SENSOR OUT ALARM CLEAR 10-19-20 9:47AM L11 DISP PAN UDC 5-6 SENSOR OUT ALARM CLEAR 10-19-20 9:47AM L10 DISP PAN UDC 3-4 SENSOR OUT ALARM CLEAR 10-19-20 9:47AM L15 OTHER VENT SUMP SENSOR OUT ALARM CLEAR 10-19-20 9:47AM I11200 OCT 19, 2020 11:57 AM 177218 7-11 22150 4012 WHITE LN Bakersfield,CA 93309 NON-PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME T 2 TANK 91 HIGH WATER WARNING ALARM 10-19-20 11:53AM T 2 TANK 91 HIGH WATER WARNING CLEAR 10-19-20 11:53AM T 2 TANK 91 HIGH WATER WARNING ALARM 10-19-20 11:49AM T 2 TANK 91 HIGH WATER WARNING CLEAR 10-19-20 11:49AM T 2 TANK 91 HIGH WATER WARNING ALARM 10-19-20 10:32AM T 2 TANK 91 LOW TEMP WARNING CLEAR 10-19-20 10:29AM T 2 TANK 91 LOW TEMP WARNING ALARM 10-19-20 10:29AM T 2 TANK 91 HIGH PRODUCT ALARM CLEAR 10-19-20 10:29AM T 2 TANK 91 HIGH PRODUCT ALARM ALARM 10-19-20 10:26AM T 1 TANK 87 HIGH WATER WARNING CLEAR 10-19-20 10:26AM T 1 TANK 87 LOW TEMP WARNING CLEAR 10-19-20 10:23AM T 3 TANK DSL HIGH WATER WARNING CLEAR 10-19-20 10:23AM T 1 TANK 87 LOW TEMP WARNING ALARM 10-19-20 10:23AM T 1 TANK 87 HIGH PRODUCT ALARM CLEAR 10-19-20 10:23AM T 2 TANK 91 HIGH WATER WARNING CLEAR 10-19-20 10:21AM T 1 TANK 87 HIGH PRODUCT ALARM ALARM 10-19-20 10:20AM T 3 TANK DSL LOW TEMP WARNING CLEAR 10-19-20 10:19AM T 3 TANK DSL LOW TEMP WARNING ALARM 10-19-20 10:19AM T 3 TANK DSL HIGH PRODUCT ALARM CLEAR 10-19-20 10:19AM T 1 TANK 87 DELIVERY NEEDED CLEAR 10-19-20 10:18AM T 2 TANK 91 DELIVERY NEEDED CLEAR 10-19-20 10:17AM T 3 TANK DSL HIGH PRODUCT ALARM ALARM 10-19-20 10:17AM T 3 TANK DSL INVALID FUEL LEVEL CLEAR 10-19-20 10:14AM T 3 TANK DSL DELIVERY NEEDED CLEAR 10-19-20 10:14AM T 2 TANK 91 HIGH WATER WARNING ALARM 10-19-20 10:13AM T 1 TANK 87 HIGH WATER WARNING ALARM 10-19-20 10:10AM T 2 TANK 91 DELIVERY NEEDED ALARM 10-19-20 10:10AM T 3 TANK DSL HIGH WATER WARNING ALARM 10-19-20 10:08AM T 1 TANK 87 DELIVERY NEEDED ALARM 10-19-20 10:07AM T 3 TANK DSL DELIVERY NEEDED ALARM 10-19-20 10:04AM T 3 TANK DSL INVALID FUEL LEVEL ALARM 10-19-20 10:04AM s11 OTHER 87 PRODUCT VACUUM WARNING CLEAR 10-12-20 5:28PM s11 OTHER 87 PRODUCT VACUUM WARNING ALARM 10-12-20 5:00PM SYSTEM PRINTER ERROR CLEAR 10-06-20 12:55PM SYSTEM PAPER OUT CLEAR 10-06-20 12:55PM SYSTEM PAPER OUT ALARM 10-06-20 12:55PM SYSTEM PRINTER ERROR ALARM 10-06-20 12:55PM SYSTEM PRINTER ERROR CLEAR 10-06-20 12:54PM SYSTEM PAPER OUT CLEAR 10-06-20 12:54PM SYSTEM PAPER OUT ALARM 10-06-20 12:53PM SYSTEM PRINTER ERROR ALARM 10-06-20 12:53PM SYSTEM PRINTER ERROR CLEAR 10-01-20 1:51PM SYSTEM PAPER OUT CLEAR 10-01-20 1:51PM SYSTEM PRINTER ERROR ALARM 10-01-20 1:51PM SYSTEM PAPER OUT ALARM 10-01-20 1:51PM SYSTEM PRINTER ERROR CLEAR 10-01-20 1:50PM SYSTEM PAPER OUT CLEAR 10-01-20 1:50PM SYSTEM PRINTER ERROR ALARM 10-01-20 1:50PM SYSTEM PAPER OUT ALARM 10-01-20 1:50PM SYSTEM PRINTER ERROR CLEAR 10-01-20 1:26PM I20600 OCT 19, 2020 11:57 AM 177218 7-11 22150 4012 WHITE LN Bakersfield,CA 93309 TANK ALARM HISTORY TANK 1 87 HIGH WATER ALARM OCT 19, 2020 10:10 AM OCT 23, 2019 10:25 AM OVERFILL ALARM OCT 19, 2020 10:20 AM AUG 6, 2020 1:06 PM AUG 6, 2020 1:04 PM LOW PRODUCT ALARM OCT 19, 2020 10:07 AM OCT 23, 2019 10:21 AM OCT 16, 2019 10:21 AM HIGH PRODUCT ALARM OCT 19, 2020 10:20 AM OCT 23, 2019 11:35 AM PROBE OUT OCT 19, 2020 10:21 AM OCT 19, 2020 10:06 AM OCT 24, 2019 5:34 AM HIGH WATER WARNING OCT 19, 2020 10:10 AM OCT 23, 2019 10:25 AM DELIVERY NEEDED OCT 19, 2020 10:07 AM NOV 16, 2019 7:00 AM OCT 23, 2019 10:21 AM MAX PRODUCT ALARM OCT 19, 2020 10:20 AM OCT 23, 2019 11:35 AM LOW TEMP WARNING OCT 19, 2020 10:23 AM OCT 23, 2019 11:38 AM TANK 2 91 SETUP DATA WARNING OCT 16, 2019 10:21 AM HIGH WATER ALARM OCT 19, 2020 10:13 AM OCT 23, 2019 10:29 AM OVERFILL ALARM OCT 19, 2020 10:26 AM OCT 23, 2019 11:19 AM OCT 23, 2019 11:08 AM LOW PRODUCT ALARM OCT 19, 2020 10:10 AM OCT 16, 2019 10:51 AM HIGH PRODUCT ALARM OCT 19, 2020 10:26 AM OCT 23, 2019 11:19 AM OCT 16, 2019 10:21 AM PROBE OUT OCT 19, 2020 11:43 AM OCT 19, 2020 10:27 AM OCT 19, 2020 10:08 AM HIGH WATER WARNING OCT 19, 2020 11:53 AM OCT 19, 2020 11:49 AM OCT 19, 2020 10:32 AM DELIVERY NEEDED OCT 19, 2020 10:10 AM APR 17, 2020 2:42 PM JAN 5, 2020 5:32 PM MAX PRODUCT ALARM OCT 19, 2020 10:26 AM OCT 23, 2019 11:19 AM LOW TEMP WARNING OCT 19, 2020 10:29 AM TANK 3 DSL SETUP DATA WARNING OCT 16, 2019 10:21 AM HIGH WATER ALARM OCT 19, 2020 10:08 AM OCT 23, 2019 10:20 AM OVERFILL ALARM OCT 19, 2020 10:16 AM OCT 23, 2019 11:30 AM LOW PRODUCT ALARM OCT 19, 2020 10:04 AM OCT 23, 2019 10:16 AM OCT 16, 2019 11:05 AM HIGH PRODUCT ALARM OCT 19, 2020 10:17 AM OCT 23, 2019 11:30 AM OCT 16, 2019 10:21 AM INVALID FUEL LEVEL OCT 19, 2020 10:04 AM OCT 23, 2019 10:16 AM OCT 16, 2019 10:09 AM PROBE OUT OCT 19, 2020 10:18 AM OCT 19, 2020 10:03 AM OCT 24, 2019 7:51 AM HIGH WATER WARNING OCT 19, 2020 10:08 AM OCT 23, 2019 10:20 AM DELIVERY NEEDED OCT 19, 2020 10:04 AM MAY 30, 2020 10:14 AM APR 29, 2020 1:06 PM MAX PRODUCT ALARM OCT 19, 2020 10:17 AM OCT 23, 2019 11:30 AM LOW TEMP WARNING OCT 19, 2020 10:19 AM OCT 23, 2019 11:33 AM TANK 5 TANK 6 TANK 7 TANK 8 TANK 9 TANK 10 TANK 11 TANK 12 TANK 13 TANK 14 TANK 15 TANK 16 I38200 OCT 19, 2020 11:58 AM I30200 OCT 19, 2020 11:58 AM 177218 7-11 22150 4012 WHITE LN Bakersfield,CA 93309 LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 87 ANNULAR OCT 19, 2020 9:46 AM SENSOR OUT ALARM OCT 19, 2020 9:10 AM LOW LIQUID ALARM OCT 19, 2020 9:08 AM HIGH LIQUID ALARM 2 87 STP OCT 19, 2020 9:46 AM SENSOR OUT ALARM OCT 19, 2020 9:07 AM FUEL ALARM OCT 24, 2019 2:23 PM FUEL ALARM 3 87 FILL OCT 19, 2020 9:46 AM SENSOR OUT ALARM OCT 19, 2020 9:07 AM FUEL ALARM OCT 24, 2019 2:22 PM FUEL ALARM 4 DSL-91 ANNULAR OCT 19, 2020 9:46 AM SENSOR OUT ALARM OCT 19, 2020 9:15 AM LOW LIQUID ALARM OCT 19, 2020 9:15 AM HIGH LIQUID ALARM 5 91 STP OCT 19, 2020 9:46 AM SENSOR OUT ALARM OCT 19, 2020 9:10 AM FUEL ALARM OCT 24, 2019 2:25 PM FUEL ALARM 6 91 FILL OCT 19, 2020 9:46 AM SENSOR OUT ALARM OCT 19, 2020 9:10 AM FUEL ALARM OCT 24, 2019 2:25 PM FUEL ALARM 7 DSL STP OCT 19, 2020 9:46 AM SENSOR OUT ALARM OCT 19, 2020 9:14 AM FUEL ALARM OCT 24, 2019 2:24 PM FUEL ALARM 8 DSL FILL OCT 19, 2020 9:46 AM SENSOR OUT ALARM OCT 19, 2020 9:14 AM FUEL ALARM OCT 24, 2019 2:24 PM FUEL ALARM 9 UDC 1-2 OCT 19, 2020 9:46 AM SENSOR OUT ALARM OCT 19, 2020 9:18 AM FUEL ALARM OCT 19, 2020 9:18 AM FUEL ALARM OCT 19, 2020 9:17 AM FUEL ALARM 10 UDC 3-4 OCT 19, 2020 9:46 AM SENSOR OUT ALARM OCT 19, 2020 9:16 AM FUEL ALARM OCT 23, 2019 10:03 AM SENSOR OUT ALARM 11 UDC 5-6 OCT 19, 2020 9:46 AM SENSOR OUT ALARM OCT 19, 2020 9:19 AM FUEL ALARM OCT 23, 2019 10:03 AM SENSOR OUT ALARM 12 UDC 7-8 OCT 19, 2020 9:46 AM SENSOR OUT ALARM OCT 19, 2020 9:19 AM FUEL ALARM OCT 23, 2019 10:03 AM SENSOR OUT ALARM 13 UDC 9-10 OCT 19, 2020 9:46 AM SENSOR OUT ALARM OCT 19, 2020 9:20 AM FUEL ALARM OCT 23, 2019 10:00 AM SENSOR OUT ALARM 14 UDC 11-12 OCT 19, 2020 9:46 AM SENSOR OUT ALARM OCT 19, 2020 9:21 AM FUEL ALARM OCT 23, 2019 10:03 AM SENSOR OUT ALARM 15 VENT SUMP OCT 19, 2020 9:46 AM SENSOR OUT ALARM OCT 19, 2020 9:27 AM FUEL ALARM OCT 24, 2019 2:27 PM FUEL ALARM I31600 OCT 19, 2020 11:58 AM 177218 7-11 22150 4012 WHITE LN Bakersfield,CA 93309 SMART SENSOR ALARM HISTORY REPORT SENSOR LOCATION 1 1-2 VFM 2 3-4 VFM 3 5-6 VFM OCT 16, 2019 11:12 AM COMMUNICATION ALARM 4 7-8 VFM OCT 16, 2019 11:12 AM COMMUNICATION ALARM 5 9-10 VFM OCT 16, 2019 11:12 AM COMMUNICATION ALARM 6 11-12 VFM OCT 16, 2019 11:12 AM COMMUNICATION ALARM 7 9-10 VPS OCT 16, 2019 11:12 AM COMMUNICATION ALARM 8 ATM P SNSR 9 VPR-UDCS OCT 19, 2020 9:32 AM HIGH LIQUID ALARM OCT 19, 2020 9:31 AM NO VACUUM ALARM OCT 25, 2019 12:03 PM VACUUM WARNING 10 87 SUMPS OCT 19, 2020 9:32 AM HIGH LIQUID ALARM OCT 19, 2020 9:31 AM NO VACUUM ALARM AUG 30, 2020 3:19 PM VACUUM WARNING 11 87 PRODUCT OCT 19, 2020 9:32 AM HIGH LIQUID ALARM OCT 19, 2020 2:02 AM NO VACUUM ALARM OCT 12, 2020 5:00 PM VACUUM WARNING 12 VENT BOX OCT 19, 2020 9:35 AM HIGH LIQUID ALARM OCT 19, 2020 9:35 AM NO VACUUM ALARM AUG 30, 2020 2:40 PM VACUUM WARNING 13 91 SUMPS OCT 19, 2020 9:35 AM HIGH LIQUID ALARM OCT 19, 2020 9:35 AM NO VACUUM ALARM AUG 30, 2020 2:43 PM VACUUM WARNING 14 91 PRODUCT OCT 19, 2020 9:35 AM HIGH LIQUID ALARM OCT 19, 2020 9:35 AM NO VACUUM ALARM SEP 11, 2020 1:55 PM VACUUM WARNING 15 DSL VENT OCT 19, 2020 9:39 AM HIGH LIQUID ALARM OCT 19, 2020 9:38 AM NO VACUUM ALARM APR 14, 2020 8:50 AM VACUUM WARNING 16 DSL SUMPS OCT 19, 2020 9:39 AM HIGH LIQUID ALARM OCT 19, 2020 9:38 AM NO VACUUM ALARM OCT 24, 2019 12:47 PM COMMUNICATION ALARM 17 DSL PRODUCT OCT 19, 2020 9:39 AM HIGH LIQUID ALARM OCT 19, 2020 9:38 AM NO VACUUM ALARM OCT 24, 2019 7:56 AM COMMUNICATION ALARM I40200 OCT 19, 2020 11:58 AM I40300 OCT 19, 2020 11:58 AM I34200 OCT 19, 2020 11:58 AM I34700 OCT 19, 2020 11:58 AM IV0100 OCT 19, 2020 11:58 AM 177218 7-11 22150 4012 WHITE LN Bakersfield,CA 93309 ISD ALARM STATUS REPORT EVR TYPE: BALANCE ISD TYPE: 01.05 VAPOR PROCESSOR TYPE: NONE OVERALL STATUS :PASS EVR VAPOR COLLECTION :PASS EVR VAPOR CONTAINMENT :PASS ISD MONITOR UP-TIME :100+ACU- EVR/ISD PASS TIME :100+ACU- WARNING ALARMS DATE TIME DESCRIPTION READING VALUE 19-11-21 00:01:33 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95+ACU- 1.95 19-11-16 00:00:35 FLOW PERFORMANCE HOSE BLOCKAGE FP 4 BLEND3 0.57 19-11-14 00:00:09 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95+ACU- 3.50 19-11-13 00:00:09 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95+ACU- 3.63 19-11-06 00:00:09 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95+ACU- 3.75 19-11-05 00:00:09 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95+ACU- 3.76 19-11-04 00:00:09 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95+ACU- 3.47 19-10-23 00:00:09 SENSOR OUT SELFTEST E 1 19-10-23 00:00:09 SETUP SELFTEST MISSING VAPOR PRESSURE SENSE(S) 19-10-23 00:00:09 SETUP SELFTEST MISSING VAPOR FLOW METER(S) FAILURE ALARMS DATE TIME DESCRIPTION READING VALUE 19-10-30 00:00:09 SETUP SELFTEST MISSING HOSE(S) 19-10-30 00:00:09 SETUP SELFTEST MISSING SHUTDOWN RELAY(S) 19-10-29 00:00:09 SETUP SELFTEST MISSING VAPOR PRESSURE SENSE(S) 19-10-29 00:00:09 SETUP SELFTEST MISSING VAPOR FLOW METER(S) 19-10-29 00:00:09 SETUP SELFTEST MISSING HOSE(S) 19-10-29 00:00:09 SETUP SELFTEST MISSING SHUTDOWN RELAY(S) 19-10-28 00:00:09 SENSOR OUT SELFTEST E 1 19-10-28 00:00:09 SETUP SELFTEST MISSING VAPOR PRESSURE SENSE(S) 19-10-28 00:00:09 SETUP SELFTEST MISSING VAPOR FLOW METER(S) 19-10-28 00:00:09 SETUP SELFTEST MISSING HOSE(S) SHUTDOWN +ACY- MISCELLANEOUS EVENTS DATE TIME DESCRIPTION ACTION/NAME 20-10-19 09:45:10 READINESS ISD:PP EVR:NN EVR READINESS PENDING 20-10-19 09:45:10 ISD STARTUP 20-10-19 09:44:58 ISD SHUTDOWN 20-10-08 00:10:21 READINESS ISD:PP EVR:PP ISD +ACY- EVR READY 20-10-07 14:30:43 READINESS ISD:PP EVR:NN EVR READINESS PENDING 20-10-07 14:30:43 ISD STARTUP 20-10-07 14:25:58 ISD SHUTDOWN 20-09-27 00:08:16 READINESS ISD:PP EVR:PP ISD +ACY- EVR READY 20-09-26 08:09:17 READINESS ISD:PP EVR:NN EVR READINESS PENDING 20-09-26 08:09:17 ISD STARTUP W.O.# SC1-3451481 Responses Received: 200 177218 7-11 22150 4012 WHITE LN Bakersfield,CA 93309 OCT 19, 2020 11:59 AM TANK PRODUCT GALLONS INCHES WATER DEG F ULLAGE 1 87 11972 68.09 0.0 84.7 7756 2 91 4568 66.36 0.8 89.5 3333 3 DSL 7074 67.84 0.0 91.1 4830 I90500 OCT 19, 2020 11:59 AM SOFTWARE REVISION LEVEL VERSION 335.00 SOFTWARE+ACM- 346335-100-A CREATED - 18.08.27.10.22 S-MODULE+ACM- 330160-104-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS BIR ISD/APM I50500 OCT 19, 2020 11:59 AM SYSTEM TYPE AND LANGUAGE FLAG SYSTEM UNITS U.S. SYSTEM LANGUAGE ENGLISH SYSTEM DATE/TIME FORMAT MON DD YYYY HH:MM:SS xM I50201 OCT 19, 2020 11:59 AM SHIFT TIME 1 : DISABLED I50202 OCT 19, 2020 11:59 AM SHIFT TIME 2 : DISABLED I50203 OCT 19, 2020 11:59 AM SHIFT TIME 3 : DISABLED I50204 OCT 19, 2020 11:59 AM SHIFT TIME 4 : DISABLED I54600 OCT 19, 2020 11:59 AM TANK PER TST NEEDED WRN: DISABLED I54900 OCT 19, 2020 11:59 AM TANK ANN TST NEEDED WRN: DISABLED I55300 OCT 19, 2020 11:59 AM LINE RE-ENABLE METHOD PASS LINE TEST I55600 OCT 19, 2020 11:59 AM LINE PER TST NEEDED WRN: DISABLED I55900 OCT 19, 2020 11:59 AM LINE ANN TST NEEDED WRN: DISABLED I50D00 OCT 19, 2020 11:59 AM PRINT TC VOLUMES ENABLED I50E00 OCT 19, 2020 11:59 AM TEMP COMPENSATION VALUE (DEG F ): 60.0 I60B00 OCT 19, 2020 11:59 AM STICK HEIGHT OFFSET ENABLE STATUS DISABLED I51400 OCT 19, 2020 11:59 AM H-PROTOCOL DATA FORMAT HEIGHT I51A01 OCT 19, 2020 11:59 AM DAYLIGHT SAVING TIME ENABLED ON I51B00 OCT 19, 2020 11:59 AM DAYLIGHT SAVING TIME START DATE MAR WEEK 2 SUN 2:00 AM END DATE NOV WEEK 1 SUN 2:00 AM I51600 OCT 19, 2020 11:59 AM RE-DIRECT LOCAL PRINTOUT DISABLED I50400 OCT 19, 2020 11:59 AM 232 SECURITY CODE PORT SECURITY CODE STATUS 1 000000 DISABLED 2 000000 DISABLED 3 000000 DISABLED 4 000000 DISABLED 5 000000 DISABLED 6 000000 DISABLED I21900 OCT 19, 2020 11:59 AM TANK CHART SECURITY DISABLED I5BD00 OCT 19, 2020 11:59 AM CUSTOM ALARM LABELS DISABLED I56000 OCT 19, 2020 11:59 AM MASS/DENSITY DISABLED I88101 OCT 19, 2020 11:59 AM PORT SETTINGS: COMM BOARD : 1 (EDIM ) RS-232 SECURITY CODE : DISABLED I88102 OCT 19, 2020 11:59 AM PORT SETTINGS: COMM BOARD : 2 (S-SAT ) BAUD RATE : 9600 PARITY : NONE STOP BIT : 1 STOP DATA LENGTH: 8 DATA RS-232 SECURITY CODE : DISABLED DTR NORMAL STATE: HIGH I88103 OCT 19, 2020 11:59 AM I88104 OCT 19, 2020 11:59 AM I88105 OCT 19, 2020 11:59 AM PORT SETTINGS: COMM BOARD : 5 (RS-485) BAUD RATE : 2400 PARITY : EVEN STOP BIT : 1 STOP DATA LENGTH: 7 DATA RS-232 SECURITY CODE : DISABLED I88106 OCT 19, 2020 11:59 AM PORT SETTINGS: COMM BOARD : 6 (MTCOMM) BAUD RATE : 9600 PARITY : ODD STOP BIT : 1 STOP DATA LENGTH: 7 DATA RS-232 SECURITY CODE : DISABLED I52000 OCT 19, 2020 11:59 AM RECEIVER AUTO DIAL TYPE +ACY- START TIME RCVR LOCATION LABEL DIAL TYPE START TIME 1 ON DATE OCT 23, 2019 DISABLED 2 ON DATE OCT 23, 2019 DISABLED 3 ON DATE OCT 23, 2019 DISABLED 4 ON DATE OCT 23, 2019 DISABLED 5 ON DATE OCT 23, 2019 DISABLED 6 ON DATE OCT 23, 2019 DISABLED 7 ON DATE OCT 23, 2019 DISABLED 8 VEEDER ROOT (FMS) WEEKLY SAT 4:51 PM I60100 OCT 19, 2020 11:59 AM TANK CONFIGURATION DEVICE LABEL CONFIGURED 1 87 ON 2 91 ON 3 DSL ON 4 OFF I60200 OCT 19, 2020 11:59 AM TANK PRODUCT LABEL TANK PRODUCT LABEL 1 87 2 91 3 DSL 4 I60300 OCT 19, 2020 11:59 AM TANK PRODUCT CODE TANK PRODUCT LABEL 1 87 1 2 91 2 3 DSL 3 4 4 I60900 OCT 19, 2020 11:59 AM TANK THERMAL COEFFICIENT TANK PRODUCT LABEL 1 87 0.000690 2 91 0.000690 3 DSL 0.000450 4 0.000000 I60700 OCT 19, 2020 11:59 AM TANK DIAMETER TANK PRODUCT LABEL INCHES 1 87 118.38 2 91 118.38 3 DSL 118.38 4 0.00 I60A00 OCT 19, 2020 11:59 AM TANK FULL VOLUME TANK PRODUCT LABEL TANK PROFILE GALLONS 1 87 4 PTS 19782 2 91 4 PTS 7901 3 DSL 4 PTS 11904 4 1 PT 0 I60400 OCT 19, 2020 11:59 AM TANK FULL VOLUME TANK PRODUCT LABEL GALLONS 1 87 19782 2 91 7901 3 DSL 11904 4 0 I60500 OCT 19, 2020 11:59 AM TANK 4 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 87 19782 16056 9897 3741 2 91 7901 6375 3954 1560 3 DSL 11904 9626 5944 2186 4 0 0 0 0 I60600 OCT 19, 2020 11:59 AM TANK 20 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 87 19782 0 0 0 0 16056 0 0 0 0 9897 0 0 0 0 3741 0 0 0 0 2 91 7901 0 0 0 0 6375 0 0 0 0 3954 0 0 0 0 1560 0 0 0 0 3 DSL 11904 0 0 0 0 9626 0 0 0 0 5944 0 0 0 0 2186 0 0 0 0 4 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 I61500 OCT 19, 2020 11:59 AM TANK PRODUCT LABEL METER DATA 1 87 YES 2 91 YES 3 DSL YES 4 NO I62F00 OCT 19, 2020 11:59 AM MAG PROBE FLOAT SIZE TANK PRODUCT LABEL FLOAT SIZE: 1 87 3.0 IN. 2 91 3.0 IN. 3 DSL 3.0 IN. I62700 OCT 19, 2020 11:59 AM TANK HIGH WATER WARNING LIMIT TANK PRODUCT LABEL INCHES 1 87 0.8 2 91 0.8 3 DSL 0.8 I64200 OCT 19, 2020 11:59 AM WATER ALARM FILTER TANK PRODUCT LABEL 1 87 LOW 2 91 LOW 3 DSL LOW I62400 OCT 19, 2020 11:59 AM TANK HIGH WATER LEVEL LIMIT TANK PRODUCT LABEL INCHES 1 87 1.0 2 91 1.0 3 DSL 1.0 I62800 OCT 19, 2020 11:59 AM TANK MAXIMUM VOLUME LIMIT TANK PRODUCT LABEL GALLONS 1 87 19782 2 91 7901 3 DSL 11904 4 0 I62300 OCT 19, 2020 11:59 AM TANK OVERFILL LEVEL LIMIT TANK PRODUCT LABEL GALLONS 1 87 17804 2 91 7111 3 DSL 10714 4 0 I62200 OCT 19, 2020 11:59 AM TANK HIGH PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 87 18793 2 91 7506 3 DSL 11309 4 0 I62900 OCT 19, 2020 11:59 AM TANK DELIVERY REQUIRED LIMIT TANK PRODUCT LABEL GALLONS 1 87 2769 2 91 1185 3 DSL 1786 4 0 I62100 OCT 19, 2020 11:59 AM TANK LOW PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 87 900 2 91 500 3 DSL 500 4 0 I62600 OCT 19, 2020 11:59 AM TANK LEAK ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 87 99 2 91 99 3 DSL 99 4 99 I62500 OCT 19, 2020 11:59 AM TANK SUDDEN LOSS LIMIT TANK PRODUCT LABEL GALLONS 1 87 99 2 91 99 3 DSL 99 4 99 I60800 OCT 19, 2020 11:59 AM TANK TILT TANK PRODUCT LABEL INCHES 1 87 0.00 2 91 0.00 3 DSL 0.00 4 0.00 I60B00 OCT 19, 2020 11:59 AM STICK HEIGHT OFFSET ENABLE STATUS DISABLED I60C00 OCT 19, 2020 11:59 AM TANK STICK HEIGHT OFFSET TANK PRODUCT LABEL INCHES 1 87 0.00 2 91 0.00 3 DSL 0.00 4 0.00 I61200 OCT 19, 2020 11:59 AM TANK MANIFOLDED PARTNERS TANK PRODUCT LABEL SIPHON MANIFOLDED TANKS LINE MANIFOLDED TANKS 1 87 NONE NONE 2 91 NONE NONE 3 DSL NONE NONE 4 NONE NONE I63600 OCT 19, 2020 11:59 AM PERIODIC LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 87 0 2 91 0 3 DSL 0 4 0 I62A00 OCT 19, 2020 11:59 AM ANNUAL LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 87 0 2 91 0 3 DSL 0 4 0 I62C00 OCT 19, 2020 11:59 AM TANK PERIODIC TEST TYPE TANK PRODUCT LABEL PERIODIC TEST TYPE 1 87 STANDARD 2 91 STANDARD 3 DSL STANDARD 4 STANDARD I62D00 OCT 19, 2020 11:59 AM TANK LEAK TEST FAIL ALARMS TANK PRODUCT LABEL 1 87 GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 2 91 GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 3 DSL GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 4 GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED I63100 OCT 19, 2020 11:59 AM TANK LEAK TEST AVERAGING TANK PRODUCT LABEL ANNUAL PERIODIC 1 87 OFF OFF 2 91 OFF OFF 3 DSL OFF OFF 4 OFF OFF I63000 OCT 19, 2020 11:59 AM IN-TANK LEAK TEST NOTIFY TANK PRODUCT LABEL TANK TEST NOTIFY: 1 87 OFF 2 91 OFF 3 DSL OFF 4 OFF I63200 OCT 19, 2020 11:59 AM TANK TEST SIPHON BREAK TANK PRODUCT LABEL SIPHON BREAK 1 87 OFF 2 91 OFF 3 DSL OFF 4 OFF I61000 OCT 19, 2020 11:59 AM TANK DELIVERY DELAY TANK PRODUCT LABEL 1 87 1 2 91 1 3 DSL 1 4 1 I63A00 OCT 19, 2020 11:59 AM LOW LEVEL PUMP THRESHOLD FOR SEQUENTIAL LINE MANIFOLD TANK PRODUCT LABEL PUMP THRESHOLD 1 87 10.00+ACU- 2 91 10.00+ACU- 3 DSL 10.00+ACU- 4 10.00+ACU- I61100 OCT 19, 2020 11:59 AM LEAK TEST METHOD - - - - - - - - - - - - TEST ON DATE : ALL TANK AUG 27, 2018 START TIME : DISABLED TEST RATE :0.20 GAL/HR DURATION : 2 HOURS TST EARLY STOP:DISABLED I61300 OCT 19, 2020 11:59 AM CSLD PROBABLITY OF DETECTION I61400 OCT 19, 2020 11:59 AM CSLD CLIMATE FACTOR I61600 OCT 19, 2020 11:59 AM TANK PRODUCT LABEL CAL UPDATE 1 87 IMMEDIATE 2 91 IMMEDIATE 3 DSL IMMEDIATE 4 IMMEDIATE I61A00 OCT 19, 2020 11:59 AM IN-TANK LEAK TEST EARLY STOP TANK PRODUCT LABEL TST EARLY STOP: 1 87 DISABLED 2 91 DISABLED 3 DSL DISABLED 4 DISABLED I61B00 OCT 19, 2020 11:59 AM IN-TANK LEAK GROSS TEST AUTO-CONFIRM I61C00 OCT 19, 2020 11:59 AM CSLD REPORT ONLY I62B00 OCT 19, 2020 11:59 AM TANK LAST ANNUAL TEST TANK PRODUCT LABEL DATE 1 87 ??? 0, 0 2 91 ??? 0, 0 3 DSL ??? 0, 0 4 ??? 0, 0 I63300 OCT 19, 2020 11:59 AM LEAK TEST REPORT FORMAT: NORMAL I63400 OCT 19, 2020 11:59 AM RECONCILIATION WARNING LIMIT TANK PRODUCT LABEL GALLONS 1 87 0 2 91 0 3 DSL 0 4 0 I63500 OCT 19, 2020 11:59 AM RECONCILIATION ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 87 1 2 91 1 3 DSL 1 4 1 I63900 OCT 19, 2020 11:59 AM ACCU CHART END SHAPE FACTOR TANK PRODUCT LABEL 1 87 END FACTOR: HEMISPHER 2 91 END FACTOR: FLAT 3 DSL END FACTOR: HEMISPHER 4 END FACTOR: NONE I78000 OCT 19, 2020 11:59 AM I77700 OCT 19, 2020 11:59 AM I77800 OCT 19, 2020 11:59 AM I78C00 OCT 19, 2020 12:00 PM I78300 OCT 19, 2020 12:00 PM I78F00 OCT 19, 2020 12:00 PM I78700 OCT 19, 2020 12:00 PM I70200 OCT 19, 2020 12:00 PM LIQUID LABEL DEVICE LABEL 1 87 ANNULAR 2 87 STP 3 87 FILL 4 DSL-91 ANNULAR 5 91 STP 6 91 FILL 7 DSL STP 8 DSL FILL 9 UDC 1-2 10 UDC 3-4 11 UDC 5-6 12 UDC 7-8 13 UDC 9-10 14 UDC 11-12 15 VENT SUMP 16 I70300 OCT 19, 2020 12:00 PM LIQUID TYPE SENSOR LOCATION TYPE 1 87 ANNULAR DUAL POINT HYDROSTATIC 2 87 STP TRI-STATE (SINGLE FLOAT) 3 87 FILL TRI-STATE (SINGLE FLOAT) 4 DSL-91 ANNULAR DUAL POINT HYDROSTATIC 5 91 STP TRI-STATE (SINGLE FLOAT) 6 91 FILL TRI-STATE (SINGLE FLOAT) 7 DSL STP TRI-STATE (SINGLE FLOAT) 8 DSL FILL TRI-STATE (SINGLE FLOAT) 9 UDC 1-2 TRI-STATE (SINGLE FLOAT) 10 UDC 3-4 TRI-STATE (SINGLE FLOAT) 11 UDC 5-6 TRI-STATE (SINGLE FLOAT) 12 UDC 7-8 TRI-STATE (SINGLE FLOAT) 13 UDC 9-10 TRI-STATE (SINGLE FLOAT) 14 UDC 11-12 TRI-STATE (SINGLE FLOAT) 15 VENT SUMP TRI-STATE (SINGLE FLOAT) 16 TRI-STATE (SINGLE FLOAT) I70400 OCT 19, 2020 12:00 PM LIQUID CATEGORY SENSOR LOCATION CATEGORY 1 87 ANNULAR ANNULAR SPACE 2 87 STP STP SUMP 3 87 FILL PIPING SUMP 4 DSL-91 ANNULAR ANNULAR SPACE 5 91 STP STP SUMP 6 91 FILL PIPING SUMP 7 DSL STP STP SUMP 8 DSL FILL PIPING SUMP 9 UDC 1-2 DISPENSER PAN 10 UDC 3-4 DISPENSER PAN 11 UDC 5-6 DISPENSER PAN 12 UDC 7-8 DISPENSER PAN 13 UDC 9-10 DISPENSER PAN 14 UDC 11-12 DISPENSER PAN 15 VENT SUMP OTHER SENSORS 16 OTHER SENSORS I74200 OCT 19, 2020 12:00 PM I74300 OCT 19, 2020 12:00 PM I74400 OCT 19, 2020 12:00 PM I74700 OCT 19, 2020 12:00 PM I74800 OCT 19, 2020 12:00 PM I74900 OCT 19, 2020 12:00 PM I7BC00 OCT 19, 2020 12:00 PM I80200 OCT 19, 2020 12:00 PM I80300 OCT 19, 2020 12:00 PM I80400 OCT 19, 2020 12:00 PM I80700 OCT 19, 2020 12:00 PM RELAY LABEL DEVICE LABEL 1 87 2 91 3 DSL 4 OVERFILL I80900 OCT 19, 2020 12:00 PM RELAY ORIENTATION RELAY DESIGNATION ORIENTATION 1 87 NORMALLY OPEN 2 91 NORMALLY OPEN 3 DSL NORMALLY OPEN 4 OVERFILL NORMALLY OPEN I80B00 OCT 19, 2020 12:00 PM RELAY TANK ASSIGNMENT RELAY DESIGNATION TANK 1 87 1 2 91 2 3 DSL 3 4 OVERFILL NONE I80A00 OCT 19, 2020 12:00 PM RELAY TYPE RELAY DESIGNATION TYPE 1 87 PUMP CONTROL OUTPUT 2 91 PUMP CONTROL OUTPUT 3 DSL PUMP CONTROL OUTPUT 4 OVERFILL STANDARD I80C00 OCT 19, 2020 12:00 PM I80800 OCT 19, 2020 12:00 PM RELAY SETUP REPORT R 1:87 TYPE: PUMP CONTROL OUTPUT TANK +ACM-: 1 LIQUID SENSOR ALMS L 2:FUEL ALARM L 3:FUEL ALARM L 9:FUEL ALARM L10:FUEL ALARM L11:FUEL ALARM L12:FUEL ALARM L13:FUEL ALARM L14:FUEL ALARM L 9:SENSOR OUT ALARM L10:SENSOR OUT ALARM L11:SENSOR OUT ALARM L12:SENSOR OUT ALARM L13:SENSOR OUT ALARM L14:SENSOR OUT ALARM L 2:SHORT ALARM L 9:SHORT ALARM L10:SHORT ALARM L11:SHORT ALARM L12:SHORT ALARM L13:SHORT ALARM L14:SHORT ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD SETUP FAIL ISD SENSOR OUT FAIL ISD HOSE ALARMS ALL:FLOW COLLECT FAIL R 2:91 TYPE: PUMP CONTROL OUTPUT TANK +ACM-: 2 LIQUID SENSOR ALMS L 5:FUEL ALARM L 6:FUEL ALARM L 9:FUEL ALARM L10:FUEL ALARM L11:FUEL ALARM L12:FUEL ALARM L13:FUEL ALARM L14:FUEL ALARM L 5:SENSOR OUT ALARM L 6:SENSOR OUT ALARM L 9:SENSOR OUT ALARM L10:SENSOR OUT ALARM L11:SENSOR OUT ALARM L12:SENSOR OUT ALARM L13:SENSOR OUT ALARM L14:SENSOR OUT ALARM L 5:SHORT ALARM L 6:SHORT ALARM L 9:SHORT ALARM L10:SHORT ALARM L11:SHORT ALARM L12:SHORT ALARM L13:SHORT ALARM L14:SHORT ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD SETUP FAIL ISD SENSOR OUT FAIL ISD HOSE ALARMS ALL:FLOW COLLECT FAIL R 3:DSL TYPE: PUMP CONTROL OUTPUT TANK +ACM-: 3 LIQUID SENSOR ALMS L 7:FUEL ALARM L 8:FUEL ALARM L10:FUEL ALARM L14:FUEL ALARM L 7:SENSOR OUT ALARM L 8:SENSOR OUT ALARM L10:SENSOR OUT ALARM L 8:SHORT ALARM L10:SHORT ALARM L14:SHORT ALARM R 4:OVERFILL TYPE: STANDARD NORMALLY OPEN TANK +ACM-: NONE IN-TANK ALARMS ALL:OVERFILL ALARM I79000 OCT 19, 2020 12:01 PM EDIM:1 VR:349867-001-D TD:17.02.14.08.38 I79100 OCT 19, 2020 12:01 PM I72300 OCT 19, 2020 12:01 PM 177218 7-11 22150 4012 WHITE LN Bakersfield,CA 93309 SMARTSENSOR ASSIGNMENT DEVICE LABEL CATEGORY 01 1-2 VFM AIR FLOW METER 02 3-4 VFM AIR FLOW METER 03 5-6 VFM AIR FLOW METER 04 7-8 VFM AIR FLOW METER 05 9-10 VFM AIR FLOW METER 06 11-12 VFM AIR FLOW METER 07 9-10 VPS VAPOR PRESSURE 08 ATM P SNSR ATM P SENSOR 09 VPR-UDCS VAC SENSOR 10 87 SUMPS VAC SENSOR 11 87 PRODUCT VAC SENSOR 12 VENT BOX VAC SENSOR 13 91 SUMPS VAC SENSOR 14 91 PRODUCT VAC SENSOR 15 DSL VENT VAC SENSOR 16 DSL SUMPS VAC SENSOR 17 DSL PRODUCT VAC SENSOR 18 UNKNOWN 19 UNKNOWN 20 UNKNOWN 21 UNKNOWN 22 UNKNOWN 23 UNKNOWN 24 UNKNOWN 25 UNKNOWN 26 UNKNOWN 27 UNKNOWN 28 UNKNOWN 29 UNKNOWN 30 UNKNOWN 31 UNKNOWN 32 UNKNOWN 33 UNKNOWN 34 UNKNOWN 35 UNKNOWN 36 UNKNOWN 37 UNKNOWN 38 UNKNOWN 39 UNKNOWN 40 UNKNOWN I72A00 OCT 19, 2020 12:01 PM VACUUM SENSOR VOLUME DEVICE LABEL VOLUME 9 VPR-UDCS 50.0 GALLONS 10 87 SUMPS 10.0 GALLONS 11 87 PRODUCT 25.0 GALLONS 12 VENT BOX 30.0 GALLONS 13 91 SUMPS 10.0 GALLONS 14 91 PRODUCT 50.0 GALLONS 15 DSL VENT 15.0 GALLONS 16 DSL SUMPS 25.0 GALLONS 17 DSL PRODUCT 25.0 GALLONS IV4E00 OCT 19, 2020 12:01 PM 177218 7-11 22150 4012 WHITE LN Bakersfield,CA 93309 EVR/ISD SETUP TYPE: BALANCE IV4F00 OCT 19, 2020 12:01 PM 177218 7-11 22150 4012 WHITE LN Bakersfield,CA 93309 NOZZLE A/L RANGE A/L RATIO: 0.95 - 1.15 IV4000 OCT 19, 2020 12:01 PM 177218 7-11 22150 4012 WHITE LN Bakersfield,CA 93309 VAPOR PROCESSOR TYPE NONE IV4700 OCT 19, 2020 12:01 PM 177218 7-11 22150 4012 WHITE LN Bakersfield,CA 93309 ASSESSMENT TIME START TIME: 11:59 PM TIME DELAY MINUTES: 1 IV5200 OCT 19, 2020 12:01 PM 177218 7-11 22150 4012 WHITE LN Bakersfield,CA 93309 ACCEPT HIGH ORVR: NO IV4A00 OCT 19, 2020 12:01 PM 177218 7-11 22150 4012 WHITE LN Bakersfield,CA 93309 ISD HOSE TABLE HOSE FP FP AFM REL HOSE ID ID LABEL ID ID LABEL 01 01 01 01 02 BLEND3 02 02 02 01 02 BLEND3 03 03 03 02 02 BLEND3 04 04 04 02 02 BLEND3 05 05 05 03 02 BLEND3 06 06 06 03 02 BLEND3 07 07 07 04 02 BLEND3 08 08 08 04 02 BLEND3 09 09 09 05 02 BLEND3 10 16 10 05 02 BLEND3 11 17 11 06 02 BLEND3 12 18 12 06 02 BLEND3 IV4B00 OCT 19, 2020 12:01 PM 177218 7-11 22150 4012 WHITE LN Bakersfield,CA 93309 PRODUCT/HOSE MAP TABLE FP AFID M1/H1 M2/H2 M3/H3 M4/H4 01 01 02/01 09/01 01/01 xx/xx 02 01 02/02 09/02 01/02 xx/xx 03 02 02/03 01/03 xx/xx xx/xx 04 02 02/04 01/04 xx/xx xx/xx 05 03 02/05 01/05 xx/xx xx/xx 06 03 02/06 01/06 xx/xx xx/xx 07 04 02/07 01/07 xx/xx xx/xx 08 04 02/08 01/08 xx/xx xx/xx 09 05 02/09 01/09 xx/xx xx/xx 16 05 02/10 01/10 xx/xx xx/xx 17 06 02/11 01/11 xx/xx xx/xx 18 06 02/12 01/12 xx/xx xx/xx IV4900 OCT 19, 2020 12:01 PM 177218 7-11 22150 4012 WHITE LN Bakersfield,CA 93309 LABEL TABLE ID LABEL 01 UNASSIGNED 02 BLEND3 03 REGULAR 04 MID GRADE 05 PREMIUM 06 GOLD 07 BRONZE 08 SILVER 09 BLEND2 10 BLEND4 IV1000 OCT 19, 2020 12:01 PM ISD VERSION: 01.05 Test Duration Test Pressure P/F Threshold Tank Annular - Vacuum 1 hr, 20k or less tank 10" hg 0 loss, int dry before and after test Tank Annular - Vacuum 2 hr, >20k tank 10" hg 0 loss, int dry before and after test Line Annular - Pressure 1 hr 5 psi 0 loss STP Sump - Hydro 1 hr 4" above highest penetration or sidewall seam less than 1/8" over hour, settle time of 15 minutes minimum prior to starting the test UDC Sump - Hydro 1 hr 4" above highest penetration or sidewall seam less than 1/8" over hour, settle time of 15 minutes minimum prior to starting the test Spill Bucket - SW Vac 1 min 30" wc no greater than 4" wc vaccum decay - bucket must be dry Spill Bucket - SW Hydro 1 hr within 1.5" of top of the bucket less than 1/8" over hour, settle time of 5 minutest minimum prior to starting the test Spill Bucket - DW Vac 1 min 15" wc no greater than 3" wc vaccum decay - int must be dry