Loading...
HomeMy WebLinkAbout2020 FMC RESULTS10/16/2020 SA098, AT&T Annual Monitor Certification & Spill Bucket Testing Notification w/Overfill Test (BKFDCA14), Bakersfield https://mail.sa.tait.com/owa/?ae=Item&t=IPM.Appointment&id=PSI.LgAAAAAaRHOQqmYRzZvIAKoAL8RaAwAe4ThZgnHuTb1WdTtldYiuAAAAA%2bj2AAAB.…1/1 SA098, AT&T Annual Monitor Certification & Spill Bucket Testing Notification w/Overfill Test (BKFDCA14), Bakersfield Simplex Communication Sent: Thursday, June 20, 2013 1:47 PM Required:RENUK, ALLEN L [ar273x@att.com] ; Knoche, Rebecca (rk9575@att.com) ; FLORES, CECILIA [cf7893@att.com] ;ATTCATesting@taitenv.onmicrosoft.com; HAYN, CINDY H (ATTSI)' (ch1921@att.com) ; Brian Harmon; Carlos Cardenas; JenniferPruitt; Maria Figueroa; CORONADO, ALEX [ac0005@att.com] ; Adolfo Aguilar When:Friday, October 09, 2020 9:00 AM-11:00 AM. Location:3221 S. H STREET, BAKERSFIELD, CA 93304-5649Show time as:Busy Accepted:No attendees have accepted. Tentative:No attendees marked their acceptance Tentative. Declined:No attendees have declined. Categories:Annual Monitoring Certification & Spill Bucket Testing; Legacy S Site Attachments:PERMIT APPLICATION SUBMITTALS... (683 KB ) ; ***Scheduling Request***AT&T ... (11 KB ) ; Relayed: SCHEDULING REQUEST**... (7 KB ) ; RE: [External] ***Schedulin... (48 KB ) There is an AT&T Annual monitor certification and spill bucket test scheduled for this location on the date and time indicated. NOTE: -Testing will include the Overfill Test of the Overfill alarm SA098 3221 S. H STREET BAKERSFIELD 93304-5649 TEST DUE DATE 10/16/2020 PERMIT REQUIRED for TESTING Please contact the Compliance Manager with any ques 10/16/2020 RE: [External] ***Scheduling Request***AT&T Annual October Testing - Bakersfield, CA https://mail.sa.tait.com/owa/?ae=Item&t=IPM.Note&id=PSI.LgAAAAAaRHOQqmYRzZvIAKoAL8RaAwAe4ThZgnHuTb1WdTtldYiuAAAAA%2bj2AAAB.RgAAA…1/2 RE: [External] ***Scheduling Request***AT&T Annual October Testing - Bakersfield, CA Peter Armagost [parmagost@bakersfieldfire.us] Sent:Wednesday, September 23, 2020 3:36 PMTo:Carlos Cardenas; Kristopher Karns [kkarns@bakersfieldfire.us] Cc:Shane Gardner [sgardner@bakersfieldfire.us] ; Jennifer Pruitt Carlos, You are confirmed for the dates you requested. Peter Armagost | Fire Prevention Officer Bakersfield Fire Department City of Bakersfield email:parmagost@bakersfieldfire.us web: www.bakersfieldfire.us phone: 661-326-3697 From: Carlos Cardenas <ccardenas@TAIT.COM> Sent: Monday, September 21, 2020 10:34 AM To: Peter Armagost <parmagost@bakersfieldfire.us>; Kristopher Karns <kkarns@bakersfieldfire.us> Cc: Shane Gardner <sgardner@bakersfieldfire.us>; Jennifer Prui 10/16/2020 RE: [External] ***Scheduling Request***AT&T Annual October Testing - Bakersfield, CA https://mail.sa.tait.com/owa/?ae=Item&t=IPM.Note&id=PSI.LgAAAAAaRHOQqmYRzZvIAKoAL8RaAwAe4ThZgnHuTb1WdTtldYiuAAAAA%2bj2AAAB.RgAAA…2/2 Tait Environmental Services, Inc. (714) 567-6418 From: Shane Gardner [mailto:sgardner@bakersfieldfire.us] Sent: Monday, September 21, 2020 10:13 AM To: Sessions <sesstank@aol.com>; jamie1.res@gmail.com; Carlos Cardenas <ccardenas@TAIT.COM>; Jerry Rangel <jerryr@calvalley.com> (jerryr@calvalley.com) <jerryr@calvalley.com>; Janelle Dockham (Janelle@ustservices.com) <Janelle@ustservices.com>; Fidel Carrillo (fidelbssr@gmail.com) <fidelbssr@gmail.com> Cc: Peter Armagost <parmagost@bakersfieldfire.us>; Kristopher Karns <kkarns@bakersfieldfire.us> Subject: [External] Permits THE FOLLLOWING PERMITS HAVE BEEN APPROVED AND CAN BE SCHEDULED ACCORDINGLY. 3301 Wible-Cathodic Protec Appendix VI Underground Storage Tank Monitoring System Certification Form CERS = California Environmental Reporting System, GPH = Gallons Per Hour, ID = Identification, ICC = International Code Council, LLD = Line Leak Detector, NA = Not Applicable, SW = Single- Walled, UDC = Under-Dispenser Containment, UST = Underground Storage Tank, VPH = Vacuum/Pressure/Hydrostatic Page 1 of 6 TYPE OF ACTION ܆܆ Installation ܆ Repair ܆ 12 Month 1. FACILITY INFORMATION CERS ID Certification Date Facility Name Facility Address City ZIP Code 2. SERVICE TECHNICIAN INFORMATION Company Performing the Certification Phone Mailing Address Service Technician Performing Test Contractor/Tank Tester License Number ICC Number ICC Expiration Date 3. TRAINING AND CERTIFICATIONS Manufacturer and Test Equipment Training Certifications Expiration Date 4. CERTIFICATION BY SERVICE TECHNICIAN CONDUCTING TEST I hereby certify that the monitoring system is operational in accordance with California Code of Regulations, title 23, division 3, chapter 16, section 2638; that required supporting documentation is attached; and all information contained herein is accurate. Service Technician Signature Date Total # of Pages SA098 ✔ 10023352 10/09/2020 Pacific Bell Telephone Co. dba AT&T California 3221 S. H St.Bakersfield 93304 TAIT Environmental Services, Inc. (714) 560-8222 701 N. Parkcenter Dr., Santa Ana, CA 92705 Adolfo Aguilar 588098 5238610 5/5/2022 Veeder-Root Level 4 / #A20066 11-12-2020 10/09/2020 Underground Storage Tank Monitoring System Certification Form Page 2 of 6 5. MONITORING SYSTEM AND PROGRAMMING A separate Monitoring System Certification Form must be prepared for each control panel. Make of Monitoring System Control Panel Model of Monitoring System Control Panel Software Version Installed Attach the post-certification reports if the monitoring system is capable of generating either;܆܆Monitoring System Set-up ܆܆ Alarm History Report Yes No NA All monitoring equipment is operational per manufacturer’s specifications?܆܆܆܆ Secondary containment systems are free of damage, debris, or liquid?܆܆܆܆ Are the audible and visual alarms operational?܆܆܆܆ All sensors have been: 1) visually inspected for wiring kinks, breaks and residual buildup on floats; and 2) tested for functionality and confirmed operational?܆܆܆܆܆܆ Are all sensors installed to detect a release at the earliest opportunity in the secondary containment?܆܆܆܆܆܆ The monitoring system set-up was reviewed, and proper settings confirmed?܆܆܆܆܆܆ Was the monitoring control panel’s backup battery visually inspected, functionally tested, and confirmed operational?܆܆܆܆܆܆ Does the flow of fuel stop at the dispenser if a release is detected in the under- dispenser containment?܆܆܆܆܆܆ Does the turbine automatically shut down if the piping secondary containment monitoring system fails to operate or is electrically disconnected?܆܆܆܆܆܆ Does the turbine automatically shut down if the piping secondary containment monitoring system detects a release? Which sensors initiate positive shut down? (Check all that apply)܆ Sump ܆ UDC ܆܆܆܆܆܆ If monitoring system alarms are relayed to a remote monitoring center, is all communication equipment operational?܆܆܆܆܆܆ Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 Veeder-Root TLS-350 Plus 324.01 ✔✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ Underground Storage Tank Monitoring System Certification Form Page 3 of 6 6. SENSOR TESTING RESULTS List only sensors tested on date of this certification. List “Sensor ID” as labeled in system programming. Additional copies of this page may be attached to accommodate all sensors tested. Sensor ID Sensor Model Component(s) Monitored Pass Fail ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 L1 794390-420 / 940306 Tank Annular Sensor ✔ L2 794380-208 / 762065 Fill Sump Sensor ✔ L3 794380-208 / 519636 Piping Sump Sensor ✔ L4 794380-208 / 492898 Transition Box Sensor ✔ L5 794390-420 / 619734 Generator Rm Piping Pan Sensor ✔ Underground Storage Tank Monitoring System Certification Form Page 4 of 6 7. LINE LEAK DETECTOR TESTING ܆܆ Check this box if line leak detectors ARE NOT installed. (Do not complete this section.) Simulated release rate verified: (Check all that apply.) ܆܆ 3 GPH ܆܆ 0.1 GPH ܆܆ 0.2 GPH Yes No NA Has the testing apparatus been properly calibrated?܆܆ ܆܆ ܆܆ For emergency generator tank systems, does the LLD create an audible and visual alarm when a leak is detected?܆܆ ܆܆ ܆܆ For mechanical LLDs, does the LLD restrict the flow through the pipe when a release is detected?܆܆ ܆܆ ܆܆ For electronic LLDs, does the turbine automatically shut off when a release is detected?܆܆ ܆܆ ܆܆ For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system is disabled or disconnected?܆܆ ܆܆ ܆܆ For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system malfunctions or fails a tightness test?܆܆ ܆܆ ܆܆ For electronic LLDs, have all accessible wiring connections been visually inspected for kinks and breaks?܆܆ ܆܆ ܆܆ Were all items on the equipment manufacturer’s maintenance checklist completed?܆܆ ܆܆ ܆܆ Were all LLDs confirmed operational within regulatory requirements?܆܆ ܆܆ ܆܆ LLD ID LLD Model Lines Monitored Pass Fail ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 ✔ Underground Storage Tank Monitoring System Certification Form Page 5 of 6 8. IN-TANK GAUGING TESTING ܆܆ Check this box if tank gauging is used only for inventory control. ܆܆ Check this box if NO tank gauging equipment is installed. (Do not complete this section if either box is checked.) Yes No NA All wiring has been: 1) visually inspected for kinks, breaks and proper entry and termination; and 2) tested for ground faults?܆܆ ܆܆ ܆܆ Were all in-tank gauging probes visually inspected for damage and residue buildup to ensure that floats move freely, functionally tested, and confirmed operational?܆܆ ܆܆ ܆܆ Was accuracy of system’s product level readings tested?܆܆ ܆܆ ܆܆ Was accuracy of system’s water level readings tested?܆܆ ܆܆ ܆܆ Were all probes reinstalled properly?܆܆ ܆܆ ܆܆ Were all items on the equipment manufacturer’s maintenance checklist completed?܆܆ ܆܆ ܆܆ Probe ID Probe Model Tanks Monitored Pass Fail ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ 9. COMMENTS Describe all answers marked “No” or “Fail” and proposed remedy. List all monitoring equipment either replaced or repaired. ✔ ✔ ✔ ✔ ✔ ✔ ✔ T1 847390-107 / 726884 SA098U001 Diesel Tank ✔ Replaced TLS-350 Back-Up Battery Prior To Test. Underground Storage Tank Monitoring System Certification Form Page 6 of 6 10. MONITORING SITE PLAN Date site plan was prepared: If a site plan has been prepared that shows all required information, you may include it, rather than this page, with your Monitoring System Certification Form. The site plan must show the general layout of tanks and identify locations of the monitoring panel, and all leak detection equipment and monitoring locations. Include a legend for all symbols depicted. 10/09/2020 Appendix IX Underground Storage Tank Overfill Prevention Equipment Inspection Report Form CERS = California Environmental Reporting System, ID = Identification, ICC = International Code Council, OPE = Overfill Prevention Equipment Page 1 of 2 TYPE OF ACTION ܆܆ Installation ܆ Repair ܆ 36 Month 1. FACILITY INFORMATION CERS ID Inspection Date Facility Name Facility Address City ZIP Code 2. SERVICE TECHNICIAN INFORMATION Company Performing the Inspection Phone Mailing Address Service Technician Performing Inspection Contractor/Tank Tester License Number ICC Number Expiration Date 3. TRAINING AND CERTIFICATIONS Manufacturer and Test Equipment Training Certifications Expiration Date 4. INSPECTION PROCEDURES INFORMATION Inspection Procedures Used Components Inspected 5. CERTIFICATION BY SERVICE TECHNICIAN CONDUCTING INSPECTION I hereby certify that the OPE was inspected in accordance with California Code of Regulations, title 23, division 3, chapter 16, section 2637.2; that required supporting documentation is attached; and all information contained herein is accurate. I understand that test procedures shall be made available upon request by the governing authority. Service Technician Signature Date Total # of Pages SA098 ✔ 10023352 10/9/2020 Pacific Bell Telephone Co. dba AT&T California 3221 S. H St. Bakersfield 93304 TAIT Environmental Services, Inc. (714) 560-8222 701 N. Parkcenter Dr., Santa Ana, CA 92705 Adolfo Aguilar 588098 5238610 5/5/2022 Veeder-Root Level 4 / #A20066 11-12-2020 Veeder-Root Overfill Testing Procddures SA098U001 Diesel Tank 10/9/2020 Underground Storage Tank Overfill Prevention Equipment Inspection Report Additional copies of this page may be attached. Attach tank chart(s), measurements, calculations, and In-Tank Setup report(s) Page 2 of 2 6. OVERFILL PREVENTION EQUIPMENT DETAILS Tank ID (one OPE per column) Are both vent and tank riser piping secondarily contained? ܆܆ Yes ܆܆ No ܆܆ Yes ܆܆ No ܆܆ Yes ܆܆ No ܆܆ Yes ܆܆ No OPE Model What is the OPE response when activated? (Check all that apply.) ܆܆ Shut off Flow ܆܆Restricts Flow ܆܆ Audible Alarm ܆܆ Visual Alarm ܆܆ Shut off Flow ܆܆Restricts Flow ܆܆ Audible Alarm ܆܆ Visual Alarm ܆܆ Shut off Flow ܆܆Restricts Flow ܆܆ Audible Alarm ܆܆ Visual Alarm ܆܆ Shut off Flow ܆܆Restricts Flow ܆܆ Audible Alarm ܆܆ Visual Alarm Are flow restrictors installed on vent piping that may interfere with the OPE operation? ܆܆ Yes ܆܆ No ܆܆ Yes ܆܆ No ܆܆ Yes ܆܆ No ܆܆ Yes ܆܆ No At what level in the tank is the OPE set to activate? (Inches from bottom of tank) What is the percent capacity of the tank at which the OPE activates? Is the OPE in proper operating condition to respond when the stored substance reaches the designated regulatory level? ܆܆ Yes ܆܆ No ܆܆ Yes ܆܆ No ܆܆ Yes ܆܆ No ܆܆ Yes ܆܆ No 7. SUMMARY OF TESTING RESULTS OPE Inspection Results ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail 1 8. COMMENTS Describe all results marked “Fail” and each proposed remedy. * Mark here if: ܆܆ Flow restrictors interfere with overfill prevention and equipment repairs required. SA098U001 ✔ 790091-001 ✔ ✔ ✔ 80.7" 90% ✔ ✔ No Other Components Inspected If Present, If Flow Restrictors Are Present They Don't Interfere w/ the Operation Of the A/V Alarm. Appendix VIII Underground Storage Tank Spill Container Testing Report Form CERS = California Environmental Reporting System, ID = Identification, ICC = International Code Council Page 1 of 2 TYPE OF ACTION ܆܆ Installation ܆ Repair ܆ 12 Month 1. FACILITY INFORMATION CERS ID Test Date Facility Name Facility Address City ZIP Code 2. SERVICE TECHNICIAN INFORMATION Company Performing the Test Phone Mailing Address Service Technician Performing Test Contractor/Tank Tester License Number ICC Number ICC Expiration Date 3. TRAINING AND CERTIFICATIONS Manufacturer and Test Equipment Training Certifications Expiration Date 4. TEST PROCEDURE INFORMATION Test Procedures Used Components Tested 5. CERTIFICATION BY SERVICE TECHNICIAN CONDUCTING TEST I hereby certify that each spill container was tested in accordance with California Code of Regulations, title 23, division 3, chapter 16, section 2637.1; that required supporting documentation is attached; and all information contained herein is accurate. I understand that test procedures shall be made available upon request by the governing authority. Service Technician Signature Date Total # of Pages SA098 ✔ 10023352 10/09/2020 Pacific Bell Telephone Co. dba AT&T California 3221 S. H St. Bakersfield 93304 TAIT Environmental Services, Inc. (714) 560-8222 701 N. Parkcenter Dr., Santa Ana, CA 92705 Adolfo Aguilar 588098 5238610 5/5/2022 Phil-Tite / #1007483708 8/7/2022 PEI/RP-1200 (Lake Test) SA098U001 Spill Bucket 10/09/2020 Underground Storage Tank Spill Container Testing Report Form Additional copies of this page may be attached. Page 2 of 2 6. SPILL CONTAINER DETAILS Test Method Developed by ܆܆ Manufacturer ܆܆ Industry Standard ܆܆ Professional Engineer Test Type ܆܆ Pressure ܆܆ Vacuum ܆܆ Hydrostatic Tank ID Spill Container Manufacturer: Method of Cathodic Protection ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other Is the spill container minimum capacity five gallons excluding riser volume? ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* Method to keep spill container empty ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other Spill Container Test Results ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail Tank ID Spill Container Manufacturer: Method of Cathodic Protection ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other Is the spill container minimum capacity five gallons excluding riser volume? ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* Method to keep spill container empty ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other Spill Container Test Results ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail 1 8. COMMENTS Describe all answers marked “Other,” “No,” or “Fail” and each proposed remedy. * Mark here if: Spill containers do not have a minimum capacity of five gallons and require replacement. ✔ ✔ SA098U001 Phil-Tite ✔ ✔ ✔ ✔ Took Non-Haz. Test Water To TAIT Shop. I50301 OCT 12, 2020 9:19 AM # 1:BKFDCA14 SA098 S-S I50302 OCT 12, 2020 9:19 AM # 2:3221 S. H ST. I50303 OCT 12, 2020 9:19 AM # 3:BAKERSFIELD,CA 93304 I50304 OCT 12, 2020 9:19 AM # 4:661-832-8370 I51700 OCT 12, 2020 9:19 AM SYSTEM TYPE AND LANGUAGE FLAG SYSTEM UNITS U.S. SYSTEM LANGUAGE ENGLISH SYSTEM DATE/TIME FORMAT MON DD YYYY HH:MM:SS xM I50F00 OCT 12, 2020 9:19 AM MON DD YYYY HH:MM:SS xM I10200 OCT 12, 2020 9:20 AM BKFDCA14 SA098 S-S 3221 S. H ST. BAKERSFIELD,CA 93304 661-832-8370 SYSTEM CONFIGURATION SLOT BOARD TYPE POWER ON RESET CURRENT 1 4 PROBE / G.T. 163785 161954 2 INTERSTITIAL BD 200879 199565 3 UNUSED 10306571 10248171 4 UNUSED 10265262 10235678 5 UNUSED 10261818 10242073 6 UNUSED 10249310 10230313 7 UNUSED 10253984 10238965 8 UNUSED 10247323 10232609 9 RELAY BOARD 14983 14962 10 UNUSED 10251789 10237136 11 UNUSED 10242063 10236839 12 UNUSED 10251033 10240284 13 UNUSED 10239736 10229295 14 UNUSED 10246737 10241412 15 UNUSED 10242820 10233552 16 UNUSED 10238506 10236146 COMM 1 FAXMODEM BOARD 40172 40102 COMM 2 UNUSED 10240833 10236839 COMM 3 UNUSED 10246661 10240125 COMM 4 UNUSED 10237503 10229632 COMM 5 UNUSED 10242385 10242303 COMM 6 UNUSED 10240341 10234205 I60100 OCT 12, 2020 9:20 AM TANK CONFIGURATION DEVICE LABEL CONFIGURED 1 DIESEL TK#SA098U001 ON 2 OFF 3 OFF 4 OFF I60200 OCT 12, 2020 9:20 AM TANK PRODUCT LABEL TANK PRODUCT LABEL 1 DIESEL TK#SA098U001 2 3 4 I60300 OCT 12, 2020 9:20 AM TANK PRODUCT CODE TANK PRODUCT LABEL 1 DIESEL TK#SA098U001 1 2 2 3 3 4 4 I60400 OCT 12, 2020 9:20 AM TANK FULL VOLUME TANK PRODUCT LABEL GALLONS 1 DIESEL TK#SA098U001 6016 2 5036 3 0 4 0 I60700 OCT 12, 2020 9:21 AM TANK DIAMETER TANK PRODUCT LABEL INCHES 1 DIESEL TK#SA098U001 95.75 2 92.00 3 0.00 4 0.00 I60900 OCT 12, 2020 9:21 AM TANK THERMAL COEFFICIENT TANK PRODUCT LABEL 1 DIESEL TK#SA098U001 0.000450 2 0.000450 3 0.000000 4 0.000000 I61200 OCT 12, 2020 9:21 AM TANK MANIFOLDED PARTNERS TANK PRODUCT LABEL SIPHON MANIFOLDED TANKS LINE MANIFOLDED TANKS 1 DIESEL TK#SA098U001 NONE NONE 2 NONE NONE 3 NONE NONE 4 NONE NONE I62100 OCT 12, 2020 9:21 AM TANK LOW PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 DIESEL TK#SA098U001 2000 2 3000 3 0 4 0 I62200 OCT 12, 2020 9:21 AM TANK HIGH PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 DIESEL TK#SA098U001 4784 2 4784 3 0 4 0 I62300 OCT 12, 2020 9:21 AM TANK OVERFILL LEVEL LIMIT TANK PRODUCT LABEL GALLONS 1 DIESEL TK#SA098U001 4532 2 4532 3 0 4 0 I62400 OCT 12, 2020 9:21 AM TANK HIGH WATER LEVEL LIMIT TANK PRODUCT LABEL INCHES 1 DIESEL TK#SA098U001 2.0 I62800 OCT 12, 2020 9:21 AM TANK MAXIMUM VOLUME LIMIT TANK PRODUCT LABEL GALLONS 1 DIESEL TK#SA098U001 6016 2 5036 3 0 4 0 I62900 OCT 12, 2020 9:21 AM TANK DELIVERY REQUIRED LIMIT TANK PRODUCT LABEL GALLONS 1 DIESEL TK#SA098U001 3000 2 3525 3 0 4 0 I70300 OCT 12, 2020 9:21 AM LIQUID TYPE SENSOR LOCATION TYPE 1 ANNULAR SPACE SENSOR TRI-STATE (SINGLE FLOAT) 2 FILL SUMP SENSOR TRI-STATE (SINGLE FLOAT) 3 PIPING SUMP SENSOR TRI-STATE (SINGLE FLOAT) 4 TRANSITION SUMP TRI-STATE (SINGLE FLOAT) 5 PIPING PAN TRI-STATE (SINGLE FLOAT) 6 TRI-STATE (SINGLE FLOAT) 7 TRI-STATE (SINGLE FLOAT) 8 TRI-STATE (SINGLE FLOAT) I90200 OCT 12, 2020 9:22 AM SOFTWARE REVISION LEVEL VERSION 324.01 SOFTWARE# 346324-100-B CREATED - 03.11.10.17.15 S-MODULE# 330160-002-A SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS CSLD I11100 OCT 12, 2020 9:22 AM BKFDCA14 SA098 S-S 3221 S. H ST. BAKERSFIELD,CA 93304 661-832-8370 PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME T 1 TANK DIESEL TK#SA098U001 HIGH WATER ALARM CLEAR 10-09-20 9:39AM T 1 TANK DIESEL TK#SA098U001 MAX PRODUCT ALARM CLEAR 10-09-20 9:39AM T 1 TANK DIESEL TK#SA098U001 PROBE OUT CLEAR 10-09-20 9:38AM T 1 TANK DIESEL TK#SA098U001 OVERFILL ALARM CLEAR 10-09-20 9:37AM T 1 TANK DIESEL TK#SA098U001 PROBE OUT ALARM 10-09-20 9:37AM T 1 TANK DIESEL TK#SA098U001 MAX PRODUCT ALARM ALARM 10-09-20 9:35AM T 1 TANK DIESEL TK#SA098U001 OVERFILL ALARM ALARM 10-09-20 9:35AM T 1 TANK DIESEL TK#SA098U001 LOW PRODUCT ALARM CLEAR 10-09-20 9:35AM T 1 TANK DIESEL TK#SA098U001 HIGH WATER ALARM ALARM 10-09-20 9:31AM T 1 TANK DIESEL TK#SA098U001 LOW PRODUCT ALARM ALARM 10-09-20 9:28AM T 1 TANK DIESEL TK#SA098U001 PROBE OUT CLEAR 10-09-20 9:28AM T 1 TANK DIESEL TK#SA098U001 PROBE OUT ALARM 10-09-20 9:25AM L 5 PIPE PIPING PAN FUEL ALARM CLEAR 10-09-20 9:14AM L 5 PIPE PIPING PAN FUEL ALARM ALARM 10-09-20 9:14AM L 4 PIPE TRANSITION SUMP FUEL ALARM CLEAR 10-09-20 9:12AM L 4 PIPE TRANSITION SUMP FUEL ALARM ALARM 10-09-20 9:11AM L 3 PIPE PIPING SUMP SENSOR FUEL ALARM CLEAR 10-09-20 9:09AM L 3 PIPE PIPING SUMP SENSOR FUEL ALARM ALARM 10-09-20 9:08AM L 2 OTHER FILL SUMP SENSOR FUEL ALARM CLEAR 10-09-20 9:05AM L 2 OTHER FILL SUMP SENSOR FUEL ALARM ALARM 10-09-20 9:04AM L 1 ANNULAR ANNULAR SPACE SENSOR FUEL ALARM CLEAR 10-09-20 9:03AM L 1 ANNULAR ANNULAR SPACE SENSOR FUEL ALARM ALARM 10-09-20 9:01AM T 1 TANK DIESEL TK#SA098U001 LOW PRODUCT ALARM CLEAR 10-16-19 12:46PM T 1 TANK DIESEL TK#SA098U001 PROBE OUT CLEAR 10-16-19 12:46PM T 1 TANK DIESEL TK#SA098U001 PROBE OUT ALARM 10-16-19 12:44PM T 1 TANK DIESEL TK#SA098U001 LOW PRODUCT ALARM ALARM 10-16-19 12:42PM T 1 TANK DIESEL TK#SA098U001 HIGH WATER ALARM CLEAR 10-16-19 12:33PM T 1 TANK DIESEL TK#SA098U001 MAX PRODUCT ALARM CLEAR 10-16-19 12:33PM T 1 TANK DIESEL TK#SA098U001 PROBE OUT CLEAR 10-16-19 12:32PM T 1 TANK DIESEL TK#SA098U001 PROBE OUT ALARM 10-16-19 12:32PM T 1 TANK DIESEL TK#SA098U001 OVERFILL ALARM CLEAR 10-16-19 12:30PM T 1 TANK DIESEL TK#SA098U001 MAX PRODUCT ALARM ALARM 10-16-19 12:29PM T 1 TANK DIESEL TK#SA098U001 OVERFILL ALARM ALARM 10-16-19 12:28PM T 1 TANK DIESEL TK#SA098U001 LOW PRODUCT ALARM CLEAR 10-16-19 12:27PM T 1 TANK DIESEL TK#SA098U001 HIGH WATER ALARM ALARM 10-16-19 12:26PM T 1 TANK DIESEL TK#SA098U001 LOW PRODUCT ALARM ALARM 10-16-19 12:23PM T 1 TANK DIESEL TK#SA098U001 PROBE OUT CLEAR 10-16-19 12:23PM T 1 TANK DIESEL TK#SA098U001 PROBE OUT ALARM 10-16-19 12:21PM L 5 PIPE PIPING PAN FUEL ALARM CLEAR 10-16-19 12:18PM L 5 PIPE PIPING PAN FUEL ALARM ALARM 10-16-19 12:17PM L 4 PIPE TRANSITION SUMP FUEL ALARM CLEAR 10-16-19 12:14PM L 4 PIPE TRANSITION SUMP FUEL ALARM ALARM 10-16-19 12:14PM L 3 PIPE PIPING SUMP SENSOR FUEL ALARM CLEAR 10-16-19 12:09PM L 3 PIPE PIPING SUMP SENSOR FUEL ALARM ALARM 10-16-19 12:08PM L 1 ANNULAR ANNULAR SPACE SENSOR FUEL ALARM CLEAR 10-16-19 12:06PM L 1 ANNULAR ANNULAR SPACE SENSOR FUEL ALARM ALARM 10-16-19 12:03PM L 2 OTHER FILL SUMP SENSOR FUEL ALARM CLEAR 10-16-19 12:03PM L 2 OTHER FILL SUMP SENSOR FUEL ALARM ALARM 10-16-19 12:00PM L 1 ANNULAR ANNULAR SPACE SENSOR FUEL ALARM CLEAR 10-16-19 11:58AM L 1 ANNULAR ANNULAR SPACE SENSOR FUEL ALARM ALARM 10-16-19 11:57AM I11200 OCT 12, 2020 9:23 AM BKFDCA14 SA098 S-S 3221 S. H ST. BAKERSFIELD,CA 93304 661-832-8370 NON-PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME T 1 TANK DIESEL TK#SA098U001 HIGH WATER WARNING CLEAR 10-09-20 9:39AM T 1 TANK DIESEL TK#SA098U001 LOW TEMP WARNING CLEAR 10-09-20 9:39AM T 1 TANK DIESEL TK#SA098U001 LOW TEMP WARNING ALARM 10-09-20 9:39AM T 1 TANK DIESEL TK#SA098U001 HIGH PRODUCT ALARM CLEAR 10-09-20 9:39AM T 1 TANK DIESEL TK#SA098U001 HIGH PRODUCT ALARM ALARM 10-09-20 9:35AM T 1 TANK DIESEL TK#SA098U001 DELIVERY NEEDED CLEAR 10-09-20 9:35AM T 1 TANK DIESEL TK#SA098U001 HIGH WATER WARNING ALARM 10-09-20 9:31AM T 1 TANK DIESEL TK#SA098U001 DELIVERY NEEDED ALARM 10-09-20 9:28AM T 1 TANK DIESEL TK#SA098U001 LOW TEMP WARNING CLEAR 10-16-19 12:46PM T 1 TANK DIESEL TK#SA098U001 LOW TEMP WARNING ALARM 10-16-19 12:46PM T 1 TANK DIESEL TK#SA098U001 DELIVERY NEEDED CLEAR 10-16-19 12:46PM T 1 TANK DIESEL TK#SA098U001 DELIVERY NEEDED ALARM 10-16-19 12:42PM T 1 TANK DIESEL TK#SA098U001 LOW TEMP WARNING CLEAR 10-16-19 12:33PM T 1 TANK DIESEL TK#SA098U001 LOW TEMP WARNING ALARM 10-16-19 12:33PM T 1 TANK DIESEL TK#SA098U001 HIGH WATER WARNING CLEAR 10-16-19 12:33PM T 1 TANK DIESEL TK#SA098U001 HIGH PRODUCT ALARM CLEAR 10-16-19 12:33PM T 1 TANK DIESEL TK#SA098U001 HIGH PRODUCT ALARM ALARM 10-16-19 12:28PM T 1 TANK DIESEL TK#SA098U001 DELIVERY NEEDED CLEAR 10-16-19 12:27PM T 1 TANK DIESEL TK#SA098U001 HIGH WATER WARNING ALARM 10-16-19 12:26PM T 1 TANK DIESEL TK#SA098U001 DELIVERY NEEDED ALARM 10-16-19 12:23PM T 1 TANK DIESEL TK#SA098U001 LOW TEMP WARNING CLEAR 7-05-19 8:26PM T 1 TANK DIESEL TK#SA098U001 LOW TEMP WARNING ALARM 7-05-19 8:24PM SYSTEM PRINTER ERROR CLEAR 10-26-18 9:21AM SYSTEM PRINTER ERROR ALARM 10-26-18 9:20AM SYSTEM PRINTER ERROR CLEAR 10-05-18 9:44AM SYSTEM PAPER OUT CLEAR 10-05-18 9:44AM SYSTEM PRINTER ERROR ALARM 10-05-18 9:44AM SYSTEM PAPER OUT ALARM 10-05-18 9:44AM T 1 TANK DIESEL TK#SA098U001 HIGH WATER WARNING CLEAR 10-05-18 9:41AM T 1 TANK DIESEL TK#SA098U001 LOW TEMP WARNING CLEAR 10-05-18 9:40AM T 1 TANK DIESEL TK#SA098U001 LOW TEMP WARNING ALARM 10-05-18 9:40AM T 1 TANK DIESEL TK#SA098U001 HIGH PRODUCT ALARM CLEAR 10-05-18 9:40AM T 1 TANK DIESEL TK#SA098U001 HIGH PRODUCT ALARM ALARM 10-05-18 9:39AM T 1 TANK DIESEL TK#SA098U001 DELIVERY NEEDED CLEAR 10-05-18 9:37AM T 1 TANK DIESEL TK#SA098U001 INVALID FUEL LEVEL CLEAR 10-05-18 9:37AM T 1 TANK DIESEL TK#SA098U001 HIGH WATER WARNING ALARM 10-05-18 9:31AM T 1 TANK DIESEL TK#SA098U001 INVALID FUEL LEVEL ALARM 10-05-18 9:29AM T 1 TANK DIESEL TK#SA098U001 DELIVERY NEEDED ALARM 10-05-18 9:28AM T 1 TANK DIESEL TK#SA098U001 LOW TEMP WARNING CLEAR 6-18-18 12:32PM T 1 TANK DIESEL TK#SA098U001 LOW TEMP WARNING ALARM 6-18-18 12:30PM T 1 TANK DIESEL TK#SA098U001 DELIVERY NEEDED CLEAR 6-18-18 12:28PM T 1 TANK DIESEL TK#SA098U001 HIGH WATER WARNING CLEAR 6-18-18 12:28PM T 1 TANK DIESEL TK#SA098U001 HIGH WATER WARNING ALARM 6-18-18 12:26PM T 1 TANK DIESEL TK#SA098U001 DELIVERY NEEDED ALARM 6-18-18 12:20PM T 1 TANK DIESEL TK#SA098U001 LOW TEMP WARNING CLEAR 10-12-17 9:44AM T 1 TANK DIESEL TK#SA098U001 HIGH WATER WARNING CLEAR 10-12-17 9:43AM T 1 TANK DIESEL TK#SA098U001 LOW TEMP WARNING ALARM 10-12-17 9:42AM T 1 TANK DIESEL TK#SA098U001 DELIVERY NEEDED CLEAR 10-12-17 9:40AM T 1 TANK DIESEL TK#SA098U001 HIGH WATER WARNING ALARM 10-12-17 9:37AM T 1 TANK DIESEL TK#SA098U001 LOW TEMP WARNING CLEAR 10-12-17 9:30AM I20600 OCT 12, 2020 9:23 AM BKFDCA14 SA098 S-S 3221 S. H ST. BAKERSFIELD,CA 93304 661-832-8370 TANK ALARM HISTORY TANK 1 DIESEL TK#SA098U001 SETUP DATA WARNING APR 26, 2004 3:45 PM LEAK ALARM JUN 2, 2006 9:35 AM HIGH WATER ALARM OCT 9, 2020 9:31 AM OCT 16, 2019 12:26 PM OCT 5, 2018 9:31 AM OVERFILL ALARM OCT 9, 2020 9:35 AM OCT 16, 2019 12:28 PM OCT 5, 2018 9:38 AM LOW PRODUCT ALARM OCT 9, 2020 9:28 AM OCT 16, 2019 12:42 PM OCT 16, 2019 12:23 PM SUDDEN LOSS ALARM JUN 2, 2006 9:04 AM HIGH PRODUCT ALARM OCT 9, 2020 9:35 AM OCT 16, 2019 12:28 PM OCT 5, 2018 9:39 AM INVALID FUEL LEVEL OCT 5, 2018 9:29 AM OCT 26, 2016 9:33 AM NOV 12, 2015 9:28 AM PROBE OUT OCT 9, 2020 9:37 AM OCT 9, 2020 9:25 AM OCT 16, 2019 12:44 PM HIGH WATER WARNING OCT 9, 2020 9:31 AM OCT 16, 2019 12:26 PM OCT 5, 2018 9:31 AM DELIVERY NEEDED OCT 9, 2020 9:28 AM OCT 16, 2019 12:42 PM OCT 16, 2019 12:23 PM MAX PRODUCT ALARM OCT 9, 2020 9:35 AM OCT 16, 2019 12:29 PM OCT 5, 2018 9:39 AM PERIODIC TEST FAIL JUN 14, 2006 1:38 AM JUN 3, 2006 9:55 AM MAY 11, 2006 7:55 AM CSLD INCR RATE WARN NOV 9, 2004 11:34 AM OCT 23, 2004 10:39 AM LOW TEMP WARNING OCT 9, 2020 9:39 AM OCT 16, 2019 12:46 PM OCT 16, 2019 12:33 PM I30200 OCT 12, 2020 9:24 AM BKFDCA14 SA098 S-S 3221 S. H ST. BAKERSFIELD,CA 93304 661-832-8370 LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 ANNULAR SPACE SENSOR OCT 9, 2020 9:01 AM FUEL ALARM OCT 16, 2019 12:03 PM FUEL ALARM OCT 16, 2019 11:57 AM FUEL ALARM 2 FILL SUMP SENSOR OCT 9, 2020 9:04 AM FUEL ALARM OCT 16, 2019 12:00 PM FUEL ALARM OCT 5, 2018 9:08 AM FUEL ALARM 3 PIPING SUMP SENSOR OCT 9, 2020 9:08 AM FUEL ALARM OCT 16, 2019 12:08 PM FUEL ALARM OCT 5, 2018 9:23 AM FUEL ALARM 4 TRANSITION SUMP OCT 9, 2020 9:11 AM FUEL ALARM OCT 16, 2019 12:14 PM FUEL ALARM OCT 5, 2018 9:17 AM FUEL ALARM 5 PIPING PAN OCT 9, 2020 9:14 AM FUEL ALARM OCT 16, 2019 12:17 PM FUEL ALARM OCT 5, 2018 9:20 AM FUEL ALARM Identification of Inspection Procedures for Overfill Prevention Equipment To Whom It May Concern: Tait Environmental Services, Inc., utilizes the following procedures when conducting Overfill Prevention Equipment Inspections: 1) Drop Tubes with Overfill Prevention Valves a) Verify information based upon Manufacturer installation instructions and follow their inspection procedures. b) If manufacturer information is not available, we conduct the inspection per PEI-RP1200-17, Section 7.1 2) Audible/Visual Alarms a) Verify programming or installation per manufacturer guidelines and test the system per manufacturer specifications. b) If manufacturer information is not available, we conduct the inspection per PEI-1200-17, Section 7.3. 3) Ballfloat Inspections are conducted following the procedures in PEI-RP1200-17, Section 7.2         Identification of Test Procedures for Secondary Containment Testing      To Whom It May Concern:     Tait Environmental Services, Inc., utilizes the following procedures when conducting Secondary  Containment Testing:  1) Containment Sumps, Transition Sumps, UDCs – Tait follows PEI‐RP1200‐17 Section 6.6 for the  accelerated test method. Tait uses the Incon TS‐1000 hydrostatic test equipment following the  attached procedures.  2) Spill Buckets; Direct Bury & Contained in Sumps – Spill buckets contained in sumps are tested  per PEI‐1200‐17, Section 6.2, however Tait Pass/Fail threshold is 0” drop in one hour. Direct Bury  Spill Buckets are test the same as containment sumps per PEI‐1200‐17, Section 6.6.  3) Tank Annular Space – testing is conducted per PEI‐1200‐17, Section 4.2  4) Piping Secondary Containment – Testing is conducted per PEI‐RP1200‐17, Section 5.3    Please consider this letter as our Test Procedure utilized when conducting Secondary Containment  Testing in lieu of either parts or the whole RP1200 document due to copyright infringement.     California Environmental Reporting System: Business Jennifer Pruitt's Account Sign Out Tools Reports Help Submittal Finished: Submittal Finished: AT&T California - SA098AT&T California - SA098 Home »Draft Submittal »Submittal Finished (10023352) Print Submittal You have submitted the following elements on 11/5/2020 to Bakersfield City Fire Department • Underground Storage Tanks • Facility Information What's Next? • Return to the Draft Submittal page. • Return to Facility Home. Version 3.05.0004 | Enhancements | CERS Central Diagnostics | Conditions of Use | Privacy Policy | Contact | Help California Environmental Reporting System: Business | © 2020 California Environmental Protection AgencyCERS Technical Support: Request Technical Assistance Unified Program/General Assistance: Contact your local regulator(s) Home Home SubmittalsSubmittals FacilitiesFacilities ComplianceCompliance My BusinessMy Business CERS Help Settings My Business: PACIFIC BELL TELEPHONE COMPANY dba A Page 1 of 2Submittal Finish: CERS Business 11/5/2020https://cersbusiness.calepa.ca.gov/768/Facility/10023352/Submittal/1750132/Finish CERS Help Settings My Business: PACIFIC BELL TELEPHONE COMPANY dba A Page 2 of 2Submittal Finish: CERS Business 11/5/2020https://cersbusiness.calepa.ca.gov/768/Facility/10023352/Submittal/1750132/Finish