HomeMy WebLinkAbout2020 FMC RESULTS10/20/2020 SA002, AT&T Annual Monitor Certification & Spill Bucket Testing Notification w/Overfill Test (BKFDCA01), Bakersfield https://mail.sa.tait.com/owa/?ae=Item&t=IPM.Appointment&id=PSI.LgAAAAAaRHOQqmYRzZvIAKoAL8RaAwAe4ThZgnHuTb1WdTtldYiuAAAAA%2bj2AAAB.…1/1 SA002, AT&T Annual Monitor Certification & Spill Bucket Testing Notification w/Overfill Test (BKFDCA01), Bakersfield Simplex Communication Sent: Thursday, June 20, 2013 1:47 PM Required:RENUK, ALLEN L [ar273x@att.com] ; Knoche, Rebecca (rk9575@att.com) ; FLORES, CECILIA [cf7893@att.com] ;ATTCATesting@taitenv.onmicrosoft.com; HAYN, CINDY H (ATTSI)' (ch1921@att.com) ; Brian Harmon; Carlos Cardenas; JenniferPruitt; Maria Figueroa; CORONADO, ALEX [ac0005@att.com] ; Adolfo Aguilar When:Thursday, October 15, 2020 9:00 AM-11:00 AM. Location:1520 20TH ST, BAKERSFIELD, CA 93301-4406Show time as:Busy Accepted:No attendees have accepted. Tentative:No attendees marked their acceptance Tentative. Declined:No attendees have declined. Categories:Annual Monitoring Certification & Spill Bucket Testing; Legacy T Site Attachments:Relayed: SCHEDULING REQUEST**... (7 KB ) ; ***Scheduling Request***AT&T ... (11 KB ) ; PERMIT APPLICATION SUBMITTALS... (683 KB ) ; RE: [External] ***Schedulin... (48 KB ) There is an AT&T Annual Monitoring Certification & Spill Bucket Test scheduled for this location on the date and time indicated. NOTE: -Testing will include the Overfill Test of the Overfill alarm SA002 1520 20TH ST BAKERSFIELD 93301-4406 TEST DUE DATE 10/23/2020 PERMIT REQUIRED for TESTING Please contact the Compliance Manager with any ques 10/20/2020 RE: [External] ***Scheduling Request***AT&T Annual October Testing - Bakersfield, CA https://mail.sa.tait.com/owa/?ae=Item&t=IPM.Note&id=PSI.LgAAAAAaRHOQqmYRzZvIAKoAL8RaAwAe4ThZgnHuTb1WdTtldYiuAAAAA%2bj2AAAB.RgAAA…1/2 RE: [External] ***Scheduling Request***AT&T Annual October Testing - Bakersfield, CA Peter Armagost [parmagost@bakersfieldfire.us] Sent:Wednesday, September 23, 2020 3:36 PMTo:Carlos Cardenas; Kristopher Karns [kkarns@bakersfieldfire.us] Cc:Shane Gardner [sgardner@bakersfieldfire.us] ; Jennifer Pruitt Carlos, You are confirmed for the dates you requested. Peter Armagost | Fire Prevention Officer Bakersfield Fire Department City of Bakersfield email:parmagost@bakersfieldfire.us web: www.bakersfieldfire.us phone: 661-326-3697 From: Carlos Cardenas <ccardenas@TAIT.COM> Sent: Monday, September 21, 2020 10:34 AM To: Peter Armagost <parmagost@bakersfieldfire.us>; Kristopher Karns <kkarns@bakersfieldfire.us> Cc: Shane Gardner <sgardner@bakersfieldfire.us>; Jennifer Prui 10/20/2020 RE: [External] ***Scheduling Request***AT&T Annual October Testing - Bakersfield, CA https://mail.sa.tait.com/owa/?ae=Item&t=IPM.Note&id=PSI.LgAAAAAaRHOQqmYRzZvIAKoAL8RaAwAe4ThZgnHuTb1WdTtldYiuAAAAA%2bj2AAAB.RgAAA…2/2 Tait Environmental Services, Inc. (714) 567-6418 From: Shane Gardner [mailto:sgardner@bakersfieldfire.us] Sent: Monday, September 21, 2020 10:13 AM To: Sessions <sesstank@aol.com>; jamie1.res@gmail.com; Carlos Cardenas <ccardenas@TAIT.COM>; Jerry Rangel <jerryr@calvalley.com> (jerryr@calvalley.com) <jerryr@calvalley.com>; Janelle Dockham (Janelle@ustservices.com) <Janelle@ustservices.com>; Fidel Carrillo (fidelbssr@gmail.com) <fidelbssr@gmail.com> Cc: Peter Armagost <parmagost@bakersfieldfire.us>; Kristopher Karns <kkarns@bakersfieldfire.us> Subject: [External] Permits THE FOLLLOWING PERMITS HAVE BEEN APPROVED AND CAN BE SCHEDULED ACCORDINGLY. 3301 Wible-Cathodic Protec Appendix VI Underground Storage Tank Monitoring System Certification Form CERS = California Environmental Reporting System, GPH = Gallons Per Hour, ID = Identification, ICC = International Code Council, LLD = Line Leak Detector, NA = Not Applicable, SW = Single- Walled, UDC = Under-Dispenser Containment, UST = Underground Storage Tank, VPH = Vacuum/Pressure/Hydrostatic Page 1 of 6 TYPE OF ACTION ܆܆ Installation ܆ Repair ܆ 12 Month 1. FACILITY INFORMATION CERS ID Certification Date Facility Name Facility Address City ZIP Code 2. SERVICE TECHNICIAN INFORMATION Company Performing the Certification Phone Mailing Address Service Technician Performing Test Contractor/Tank Tester License Number ICC Number ICC Expiration Date 3. TRAINING AND CERTIFICATIONS Manufacturer and Test Equipment Training Certifications Expiration Date 4. CERTIFICATION BY SERVICE TECHNICIAN CONDUCTING TEST I hereby certify that the monitoring system is operational in accordance with California Code of Regulations, title 23, division 3, chapter 16, section 2638; that required supporting documentation is attached; and all information contained herein is accurate. Service Technician Signature Date Total # of Pages SA002 ✔ 10029370 10/15/2020 Pacific Bell Telephone Co. dba AT&T California 1520 20th St.Bakersfield 93301 TAIT Environmental Services, Inc. (714) 560-8222 701 N. Parkcenter Dr., Santa Ana, CA 92705 Adolfo Aguilar 588098 5238610 5/5/2022 Veeder-Root Level 4 / #A20066 11-12-2020 10/15/2020 Underground Storage Tank Monitoring System Certification Form Page 2 of 6 5. MONITORING SYSTEM AND PROGRAMMING A separate Monitoring System Certification Form must be prepared for each control panel. Make of Monitoring System Control Panel Model of Monitoring System Control Panel Software Version Installed Attach the post-certification reports if the monitoring system is capable of generating either;܆܆Monitoring System Set-up ܆܆ Alarm History Report Yes No NA All monitoring equipment is operational per manufacturer’s specifications?܆܆܆܆ Secondary containment systems are free of damage, debris, or liquid?܆܆܆܆ Are the audible and visual alarms operational?܆܆܆܆ All sensors have been: 1) visually inspected for wiring kinks, breaks and residual buildup on floats; and 2) tested for functionality and confirmed operational?܆܆܆܆܆܆ Are all sensors installed to detect a release at the earliest opportunity in the secondary containment?܆܆܆܆܆܆ The monitoring system set-up was reviewed, and proper settings confirmed?܆܆܆܆܆܆ Was the monitoring control panel’s backup battery visually inspected, functionally tested, and confirmed operational?܆܆܆܆܆܆ Does the flow of fuel stop at the dispenser if a release is detected in the under- dispenser containment?܆܆܆܆܆܆ Does the turbine automatically shut down if the piping secondary containment monitoring system fails to operate or is electrically disconnected?܆܆܆܆܆܆ Does the turbine automatically shut down if the piping secondary containment monitoring system detects a release? Which sensors initiate positive shut down? (Check all that apply)܆ Sump ܆ UDC ܆܆܆܆܆܆ If monitoring system alarms are relayed to a remote monitoring center, is all communication equipment operational?܆܆܆܆܆܆ Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 Veeder-Root TLS-350 Plus 120.00 ✔✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ Underground Storage Tank Monitoring System Certification Form Page 3 of 6 6. SENSOR TESTING RESULTS List only sensors tested on date of this certification. List “Sensor ID” as labeled in system programming. Additional copies of this page may be attached to accommodate all sensors tested. Sensor ID Sensor Model Component(s) Monitored Pass Fail ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 L1 794380-208 / N-A Fill Sump Sensor ✔ L2 794380-208 / N-A Piping Sump Sensor ✔ L3 794380-208 / 454053 Day Tank Containment Pan Sensor ✔ L4 794380-208 / 454345 AST Day Tank Annular Sensor ✔ L5 794390-420 / 453457 UST Tank Annular Sensor ✔ L6 794380-208 / 877657 Transition Piping Sump Sensor ✔ L7 794380-208 / N-A Remote Pump Cabinet Sensor ✔ Underground Storage Tank Monitoring System Certification Form Page 4 of 6 7. LINE LEAK DETECTOR TESTING ܆܆ Check this box if line leak detectors ARE NOT installed. (Do not complete this section.) Simulated release rate verified: (Check all that apply.) ܆܆ 3 GPH ܆܆ 0.1 GPH ܆܆ 0.2 GPH Yes No NA Has the testing apparatus been properly calibrated?܆܆ ܆܆ ܆܆ For emergency generator tank systems, does the LLD create an audible and visual alarm when a leak is detected?܆܆ ܆܆ ܆܆ For mechanical LLDs, does the LLD restrict the flow through the pipe when a release is detected?܆܆ ܆܆ ܆܆ For electronic LLDs, does the turbine automatically shut off when a release is detected?܆܆ ܆܆ ܆܆ For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system is disabled or disconnected?܆܆ ܆܆ ܆܆ For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system malfunctions or fails a tightness test?܆܆ ܆܆ ܆܆ For electronic LLDs, have all accessible wiring connections been visually inspected for kinks and breaks?܆܆ ܆܆ ܆܆ Were all items on the equipment manufacturer’s maintenance checklist completed?܆܆ ܆܆ ܆܆ Were all LLDs confirmed operational within regulatory requirements?܆܆ ܆܆ ܆܆ LLD ID LLD Model Lines Monitored Pass Fail ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 ✔ Underground Storage Tank Monitoring System Certification Form Page 5 of 6 8. IN-TANK GAUGING TESTING ܆܆ Check this box if tank gauging is used only for inventory control. ܆܆ Check this box if NO tank gauging equipment is installed. (Do not complete this section if either box is checked.) Yes No NA All wiring has been: 1) visually inspected for kinks, breaks and proper entry and termination; and 2) tested for ground faults?܆܆ ܆܆ ܆܆ Were all in-tank gauging probes visually inspected for damage and residue buildup to ensure that floats move freely, functionally tested, and confirmed operational?܆܆ ܆܆ ܆܆ Was accuracy of system’s product level readings tested?܆܆ ܆܆ ܆܆ Was accuracy of system’s water level readings tested?܆܆ ܆܆ ܆܆ Were all probes reinstalled properly?܆܆ ܆܆ ܆܆ Were all items on the equipment manufacturer’s maintenance checklist completed?܆܆ ܆܆ ܆܆ Probe ID Probe Model Tanks Monitored Pass Fail ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ 9. COMMENTS Describe all answers marked “No” or “Fail” and proposed remedy. List all monitoring equipment either replaced or repaired. ✔ ✔ ✔ ✔ ✔ ✔ ✔ T1 846390-105 / 234300 SA002U001 Diesel Tank (UST Main Tank) ✔ T2 847390-301 / 620656 SA002A002 Diesel Tank (AST Day Tank ) ✔ Underground Storage Tank Monitoring System Certification Form Page 6 of 6 10. MONITORING SITE PLAN Date site plan was prepared: If a site plan has been prepared that shows all required information, you may include it, rather than this page, with your Monitoring System Certification Form. The site plan must show the general layout of tanks and identify locations of the monitoring panel, and all leak detection equipment and monitoring locations. Include a legend for all symbols depicted. 10/15/2020 Appendix IX Underground Storage Tank Overfill Prevention Equipment Inspection Report Form CERS = California Environmental Reporting System, ID = Identification, ICC = International Code Council, OPE = Overfill Prevention Equipment Page 1 of 2 TYPE OF ACTION ܆܆ Installation ܆ Repair ܆ 36 Month 1. FACILITY INFORMATION CERS ID Inspection Date Facility Name Facility Address City ZIP Code 2. SERVICE TECHNICIAN INFORMATION Company Performing the Inspection Phone Mailing Address Service Technician Performing Inspection Contractor/Tank Tester License Number ICC Number Expiration Date 3. TRAINING AND CERTIFICATIONS Manufacturer and Test Equipment Training Certifications Expiration Date 4. INSPECTION PROCEDURES INFORMATION Inspection Procedures Used Components Inspected 5. CERTIFICATION BY SERVICE TECHNICIAN CONDUCTING INSPECTION I hereby certify that the OPE was inspected in accordance with California Code of Regulations, title 23, division 3, chapter 16, section 2637.2; that required supporting documentation is attached; and all information contained herein is accurate. I understand that test procedures shall be made available upon request by the governing authority. Service Technician Signature Date Total # of Pages SA002 ✔ 10029370 10/15/2020 Pacific Bell Telephone Co. dba AT&T California 1520 20th St. Bakersfield 93301 TAIT Environmental Services, Inc. (714) 560-8222 701 N. Parkcenter Dr., Santa Ana, CA 92705 Adolfo Aguilar 588098 5238610 5/5/2022 Veeder-Root Level 4 / #A20066 11-12-2020 Veeder-Root Overfill Testing Procedures SA002U001 Diesel Tank 10/15/2020 Underground Storage Tank Overfill Prevention Equipment Inspection Report Additional copies of this page may be attached. Attach tank chart(s), measurements, calculations, and In-Tank Setup report(s) Page 2 of 2 6. OVERFILL PREVENTION EQUIPMENT DETAILS Tank ID (one OPE per column) Are both vent and tank riser piping secondarily contained? ܆܆ Yes ܆܆ No ܆܆ Yes ܆܆ No ܆܆ Yes ܆܆ No ܆܆ Yes ܆܆ No OPE Model What is the OPE response when activated? (Check all that apply.) ܆܆ Shut off Flow ܆܆Restricts Flow ܆܆ Audible Alarm ܆܆ Visual Alarm ܆܆ Shut off Flow ܆܆Restricts Flow ܆܆ Audible Alarm ܆܆ Visual Alarm ܆܆ Shut off Flow ܆܆Restricts Flow ܆܆ Audible Alarm ܆܆ Visual Alarm ܆܆ Shut off Flow ܆܆Restricts Flow ܆܆ Audible Alarm ܆܆ Visual Alarm Are flow restrictors installed on vent piping that may interfere with the OPE operation? ܆܆ Yes ܆܆ No ܆܆ Yes ܆܆ No ܆܆ Yes ܆܆ No ܆܆ Yes ܆܆ No At what level in the tank is the OPE set to activate? (Inches from bottom of tank) What is the percent capacity of the tank at which the OPE activates? Is the OPE in proper operating condition to respond when the stored substance reaches the designated regulatory level? ܆܆ Yes ܆܆ No ܆܆ Yes ܆܆ No ܆܆ Yes ܆܆ No ܆܆ Yes ܆܆ No 7. SUMMARY OF TESTING RESULTS OPE Inspection Results ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail 1 8. COMMENTS Describe all results marked “Fail” and each proposed remedy. * Mark here if: ܆܆ Flow restrictors interfere with overfill prevention and equipment repairs required. SA002U001 ✔ 790091-001 ✔ ✔ ✔ 69.2" 90% ✔ ✔ Per MRP Main Overfill Prevention Is The Overfill Alarm, No Other Components Inspected If Present. If Flow Restrictors Present They Don't Interfere w/ Operation Of The A/V Alarm. Appendix VIII Underground Storage Tank Spill Container Testing Report Form CERS = California Environmental Reporting System, ID = Identification, ICC = International Code Council Page 1 of 2 TYPE OF ACTION ܆܆ Installation ܆ Repair ܆ 12 Month 1. FACILITY INFORMATION CERS ID Test Date Facility Name Facility Address City ZIP Code 2. SERVICE TECHNICIAN INFORMATION Company Performing the Test Phone Mailing Address Service Technician Performing Test Contractor/Tank Tester License Number ICC Number ICC Expiration Date 3. TRAINING AND CERTIFICATIONS Manufacturer and Test Equipment Training Certifications Expiration Date 4. TEST PROCEDURE INFORMATION Test Procedures Used Components Tested 5. CERTIFICATION BY SERVICE TECHNICIAN CONDUCTING TEST I hereby certify that each spill container was tested in accordance with California Code of Regulations, title 23, division 3, chapter 16, section 2637.1; that required supporting documentation is attached; and all information contained herein is accurate. I understand that test procedures shall be made available upon request by the governing authority. Service Technician Signature Date Total # of Pages SA002 ✔ 10029370 10/15/2020 Pacific Bell Telephone Co. dba AT&T California 1520 20th St. Bakersfield 93301 TAIT Environmental Services, Inc. (714) 560-8222 701 N. Parkcenter Dr., Santa Ana, CA 92705 Adolfo Aguilar 588098 5238610 5/5/2022 CNI / 3719 2/28/2022 PEI/RP-1200 (Lake Test) SA002U001 Diesel 10/15/2020 Underground Storage Tank Spill Container Testing Report Form Additional copies of this page may be attached. Page 2 of 2 6. SPILL CONTAINER DETAILS Test Method Developed by ܆܆ Manufacturer ܆܆ Industry Standard ܆܆ Professional Engineer Test Type ܆܆ Pressure ܆܆ Vacuum ܆܆ Hydrostatic Tank ID Spill Container Manufacturer: Method of Cathodic Protection ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other Is the spill container minimum capacity five gallons excluding riser volume? ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* Method to keep spill container empty ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other Spill Container Test Results ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail Tank ID Spill Container Manufacturer: Method of Cathodic Protection ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other Is the spill container minimum capacity five gallons excluding riser volume? ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* Method to keep spill container empty ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other Spill Container Test Results ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail 1 8. COMMENTS Describe all answers marked “Other,” “No,” or “Fail” and each proposed remedy. * Mark here if: Spill containers do not have a minimum capacity of five gallons and require replacement. ✔ SA002U001 Diesel CNI ✔ ✔ ✔ ✔ Took Non-Haz. Test Water To TAIT Shop. I50301 OCT 16, 2020 9:56 AM # 1:BKFDCA01 SA002 T-S I50302 OCT 16, 2020 9:56 AM # 2:1520 20TH ST I50303 OCT 16, 2020 9:56 AM # 3:BAKERSFIELD,CA 93301 I50304 OCT 16, 2020 9:56 AM # 4:661-869-1846 I51700 OCT 16, 2020 9:56 AM SYSTEM TYPE AND LANGUAGE FLAG SYSTEM UNITS U.S. SYSTEM LANGUAGE ENGLISH SYSTEM DATE/TIME FORMAT MON DD YYYY HH:MM:SS xM I50F00 OCT 16, 2020 9:56 AM MON DD YYYY HH:MM:SS xM I10200 OCT 16, 2020 9:57 AM BKFDCA01 SA002 T-S 1520 20TH ST BAKERSFIELD,CA 93301 661-869-1846 SYSTEM CONFIGURATION SLOT BOARD TYPE POWER ON RESET CURRENT 1 4 PROBE / G.T. 162295 162260 2 INTERSTITIAL BD 201439 200535 3 UNUSED 15000000 15000000 4 UNUSED 15000000 15000000 5 UNUSED 15000000 15000000 6 UNUSED 15000000 15000000 7 UNUSED 15000000 15000000 8 UNUSED 15000000 15000000 9 RELAY BOARD 14933 14955 10 COMBO I/O BOARD 9929 9914 11 UNUSED 15000000 15000000 12 UNUSED 15000000 15000000 13 UNUSED 15000000 15000000 14 UNUSED 15000000 15000000 15 UNUSED 15000000 15000000 16 UNUSED 15000000 15000000 COMM 1 FAXMODEM BOARD 40571 40583 COMM 2 UNUSED 15000000 15000000 COMM 3 UNUSED 15000000 15000000 COMM 4 UNUSED 15000000 15000000 COMM 5 UNUSED 15000000 15000000 COMM 6 UNUSED 15000000 15000000 I60100 OCT 16, 2020 9:57 AM TANK CONFIGURATION DEVICE LABEL CONFIGURED 1 DIESEL TK#SA002U001 ON 2 DIESEL TK#SA002A002 ON 3 OFF 4 OFF I60200 OCT 16, 2020 9:57 AM TANK PRODUCT LABEL TANK PRODUCT LABEL 1 DIESEL TK#SA002U001 2 DIESEL TK#SA002A002 3 4 I60300 OCT 16, 2020 9:57 AM TANK PRODUCT CODE TANK PRODUCT LABEL 1 DIESEL TK#SA002U001 1 2 DIESEL TK#SA002A002 1 3 3 4 4 I60400 OCT 16, 2020 9:57 AM TANK FULL VOLUME TANK PRODUCT LABEL GALLONS 1 DIESEL TK#SA002U001 8002 2 DIESEL TK#SA002A002 250 3 0 4 0 I60700 OCT 16, 2020 9:57 AM TANK DIAMETER TANK PRODUCT LABEL INCHES 1 DIESEL TK#SA002U001 82.00 2 DIESEL TK#SA002A002 30.00 3 0.00 4 0.00 I60900 OCT 16, 2020 9:57 AM TANK THERMAL COEFFICIENT TANK PRODUCT LABEL 1 DIESEL TK#SA002U001 0.000450 2 DIESEL TK#SA002A002 0.000450 3 0.000000 4 0.000000 I61200 OCT 16, 2020 9:57 AM TANK MANIFOLDED PARTNERS TANK PRODUCT LABEL MANIFOLDED TANKS 1 DIESEL TK#SA002U001 NONE 2 DIESEL TK#SA002A002 NONE 3 NONE 4 NONE I62100 OCT 16, 2020 9:57 AM TANK LOW PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 DIESEL TK#SA002U001 4000 2 DIESEL TK#SA002A002 105 3 0 4 0 I62200 OCT 16, 2020 9:57 AM TANK HIGH PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 DIESEL TK#SA002U001 7601 2 DIESEL TK#SA002A002 237 3 0 4 0 I62300 OCT 16, 2020 9:57 AM TANK OVERFILL LEVEL LIMIT TANK PRODUCT LABEL GALLONS 1 DIESEL TK#SA002U001 7201 2 DIESEL TK#SA002A002 225 3 0 4 0 I62400 OCT 16, 2020 9:57 AM TANK HIGH WATER LEVEL LIMIT TANK PRODUCT LABEL INCHES 1 DIESEL TK#SA002U001 2.0 2 DIESEL TK#SA002A002 2.0 I62800 OCT 16, 2020 9:57 AM TANK MAXIMUM VOLUME LIMIT TANK PRODUCT LABEL GALLONS 1 DIESEL TK#SA002U001 8002 2 DIESEL TK#SA002A002 250 3 0 4 0 I62900 OCT 16, 2020 9:57 AM TANK DELIVERY REQUIRED LIMIT TANK PRODUCT LABEL GALLONS 1 DIESEL TK#SA002U001 4000 2 DIESEL TK#SA002A002 125 3 0 4 0 I70300 OCT 16, 2020 9:58 AM LIQUID TYPE SENSOR LOCATION TYPE 1 FILL SUMP TRI-STATE (SINGLE FLOAT) 2 PIPING SUMP TRI-STATE (SINGLE FLOAT) 3 DAYTANK RUPTURE BASN TRI-STATE (SINGLE FLOAT) 4 DAY TANK ANNULAR TRI-STATE (SINGLE FLOAT) 5 ANNULAR UST TRI-STATE (SINGLE FLOAT) 6 TRANSITION SUMP TRI-STATE (SINGLE FLOAT) 7 REMOTE PUMP CABINET TRI-STATE (SINGLE FLOAT) 8 TRI-STATE (SINGLE FLOAT) I90200 OCT 16, 2020 9:58 AM SOFTWARE REVISION LEVEL VERSION 120.00 SOFTWARE# 346120-100-A CREATED - 00.07.28.15.33 S-MODULE# 330160-002-A SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS CSLD I11100 OCT 16, 2020 9:58 AM BKFDCA01 SA002 T-S 1520 20TH ST BAKERSFIELD,CA 93301 661-869-1846 PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME T 2 TANK DIESEL TK#SA002A002 MAX PRODUCT ALARM CLEAR 10-15-20 9:50AM T 2 TANK DIESEL TK#SA002A002 PROBE OUT CLEAR 10-15-20 9:50AM T 2 TANK DIESEL TK#SA002A002 PROBE OUT ALARM 10-15-20 9:49AM T 2 TANK DIESEL TK#SA002A002 MAX PRODUCT ALARM ALARM 10-15-20 9:46AM T 2 TANK DIESEL TK#SA002A002 PROBE OUT CLEAR 10-15-20 9:44AM T 2 TANK DIESEL TK#SA002A002 PROBE OUT ALARM 10-15-20 9:41AM L 3 OTHER DAYTANK RUPTURE BASN FUEL ALARM CLEAR 10-15-20 9:39AM L 3 OTHER DAYTANK RUPTURE BASN FUEL ALARM ALARM 10-15-20 9:39AM L 4 ANNULAR DAY TANK ANNULAR FUEL ALARM CLEAR 10-15-20 9:36AM L 4 ANNULAR DAY TANK ANNULAR FUEL ALARM ALARM 10-15-20 9:35AM L 7 OTHER REMOTE PUMP CABINET FUEL ALARM CLEAR 10-15-20 9:20AM L 7 OTHER REMOTE PUMP CABINET FUEL ALARM ALARM 10-15-20 9:19AM L 6 PIPE TRANSITION SUMP FUEL ALARM CLEAR 10-15-20 9:18AM L 6 PIPE TRANSITION SUMP FUEL ALARM ALARM 10-15-20 9:17AM T 1 TANK DIESEL TK#SA002U001 HIGH WATER ALARM CLEAR 10-15-20 9:15AM T 1 TANK DIESEL TK#SA002U001 MAX PRODUCT ALARM CLEAR 10-15-20 9:13AM T 1 TANK DIESEL TK#SA002U001 PROBE OUT CLEAR 10-15-20 9:13AM T 1 TANK DIESEL TK#SA002U001 OVERFILL ALARM CLEAR 10-15-20 9:12AM T 1 TANK DIESEL TK#SA002U001 PROBE OUT ALARM 10-15-20 9:12AM T 1 TANK DIESEL TK#SA002U001 MAX PRODUCT ALARM ALARM 10-15-20 9:12AM T 1 TANK DIESEL TK#SA002U001 OVERFILL ALARM ALARM 10-15-20 9:12AM T 1 TANK DIESEL TK#SA002U001 LOW PRODUCT ALARM CLEAR 10-15-20 9:11AM L 2 PIPE PIPING SUMP FUEL ALARM CLEAR 10-15-20 9:08AM L 2 PIPE PIPING SUMP FUEL ALARM ALARM 10-15-20 9:08AM L 1 STP SUMP FILL SUMP FUEL ALARM CLEAR 10-15-20 9:04AM L 1 STP SUMP FILL SUMP FUEL ALARM ALARM 10-15-20 9:04AM L 5 ANNULAR ANNULAR UST FUEL ALARM CLEAR 10-15-20 9:00AM L 5 ANNULAR ANNULAR UST FUEL ALARM ALARM 10-15-20 9:00AM T 1 TANK DIESEL TK#SA002U001 HIGH WATER ALARM ALARM 10-15-20 8:33AM T 1 TANK DIESEL TK#SA002U001 LOW PRODUCT ALARM ALARM 10-15-20 8:29AM T 1 TANK DIESEL TK#SA002U001 PROBE OUT CLEAR 10-15-20 8:29AM T 1 TANK DIESEL TK#SA002U001 PROBE OUT ALARM 10-15-20 8:26AM T 2 TANK DIESEL TK#SA002A002 MAX PRODUCT ALARM CLEAR 10-23-19 10:30AM T 2 TANK DIESEL TK#SA002A002 PROBE OUT CLEAR 10-23-19 10:30AM T 2 TANK DIESEL TK#SA002A002 PROBE OUT ALARM 10-23-19 10:29AM T 2 TANK DIESEL TK#SA002A002 OVERFILL ALARM CLEAR 10-23-19 10:28AM T 2 TANK DIESEL TK#SA002A002 MAX PRODUCT ALARM ALARM 10-23-19 10:26AM T 2 TANK DIESEL TK#SA002A002 OVERFILL ALARM ALARM 10-23-19 10:26AM T 2 TANK DIESEL TK#SA002A002 LOW PRODUCT ALARM CLEAR 10-23-19 10:26AM T 2 TANK DIESEL TK#SA002A002 LOW PRODUCT ALARM ALARM 10-23-19 10:24AM T 2 TANK DIESEL TK#SA002A002 PROBE OUT CLEAR 10-23-19 10:24AM T 2 TANK DIESEL TK#SA002A002 PROBE OUT ALARM 10-23-19 10:23AM L 3 OTHER DAYTANK RUPTURE BASN FUEL ALARM CLEAR 10-23-19 10:19AM L 3 OTHER DAYTANK RUPTURE BASN FUEL ALARM ALARM 10-23-19 10:19AM L 4 ANNULAR DAY TANK ANNULAR FUEL ALARM CLEAR 10-23-19 10:17AM L 4 ANNULAR DAY TANK ANNULAR FUEL ALARM ALARM 10-23-19 10:16AM L 7 OTHER REMOTE PUMP CABINET FUEL ALARM CLEAR 10-23-19 9:29AM L 7 OTHER REMOTE PUMP CABINET FUEL ALARM ALARM 10-23-19 9:28AM L 6 PIPE TRANSITION SUMP FUEL ALARM CLEAR 10-23-19 9:24AM L 6 PIPE TRANSITION SUMP FUEL ALARM ALARM 10-23-19 9:24AM I11200 OCT 16, 2020 9:59 AM BKFDCA01 SA002 T-S 1520 20TH ST BAKERSFIELD,CA 93301 661-869-1846 NON-PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME SYSTEM PRINTER ERROR CLEAR 10-15-20 10:24AM SYSTEM PAPER OUT CLEAR 10-15-20 10:24AM SYSTEM PRINTER ERROR ALARM 10-15-20 10:24AM SYSTEM PAPER OUT ALARM 10-15-20 10:24AM T 2 TANK DIESEL TK#SA002A002 HIGH PRODUCT ALARM CLEAR 10-15-20 9:50AM T 2 TANK DIESEL TK#SA002A002 HIGH PRODUCT ALARM ALARM 10-15-20 9:46AM T 1 TANK DIESEL TK#SA002U001 HIGH WATER WARNING CLEAR 10-15-20 9:15AM T 1 TANK DIESEL TK#SA002U001 HIGH PRODUCT ALARM CLEAR 10-15-20 9:13AM T 1 TANK DIESEL TK#SA002U001 HIGH PRODUCT ALARM ALARM 10-15-20 9:12AM T 1 TANK DIESEL TK#SA002U001 DELIVERY NEEDED CLEAR 10-15-20 9:11AM T 1 TANK DIESEL TK#SA002U001 HIGH WATER WARNING ALARM 10-15-20 8:33AM T 1 TANK DIESEL TK#SA002U001 DELIVERY NEEDED ALARM 10-15-20 8:29AM T 2 TANK DIESEL TK#SA002A002 HIGH PRODUCT ALARM CLEAR 10-23-19 10:30AM T 2 TANK DIESEL TK#SA002A002 HIGH PRODUCT ALARM ALARM 10-23-19 10:26AM T 2 TANK DIESEL TK#SA002A002 DELIVERY NEEDED CLEAR 10-23-19 10:26AM T 2 TANK DIESEL TK#SA002A002 INVALID FUEL LEVEL CLEAR 10-23-19 10:26AM T 2 TANK DIESEL TK#SA002A002 DELIVERY NEEDED ALARM 10-23-19 10:24AM T 2 TANK DIESEL TK#SA002A002 INVALID FUEL LEVEL ALARM 10-23-19 10:24AM T 1 TANK DIESEL TK#SA002U001 HIGH WATER WARNING CLEAR 10-23-19 9:16AM T 1 TANK DIESEL TK#SA002U001 HIGH PRODUCT ALARM CLEAR 10-23-19 9:16AM T 1 TANK DIESEL TK#SA002U001 HIGH PRODUCT ALARM ALARM 10-23-19 9:12AM T 1 TANK DIESEL TK#SA002U001 DELIVERY NEEDED CLEAR 10-23-19 9:11AM T 1 TANK DIESEL TK#SA002U001 HIGH WATER WARNING ALARM 10-23-19 9:04AM T 1 TANK DIESEL TK#SA002U001 DELIVERY NEEDED ALARM 10-23-19 9:01AM T 2 TANK DIESEL TK#SA002A002 HIGH PRODUCT ALARM CLEAR 11-02-18 10:40AM T 2 TANK DIESEL TK#SA002A002 HIGH PRODUCT ALARM ALARM 11-02-18 10:38AM T 2 TANK DIESEL TK#SA002A002 DELIVERY NEEDED CLEAR 11-02-18 10:38AM T 2 TANK DIESEL TK#SA002A002 DELIVERY NEEDED ALARM 11-02-18 10:37AM T 1 TANK DIESEL TK#SA002U001 HIGH WATER WARNING CLEAR 11-02-18 9:29AM T 1 TANK DIESEL TK#SA002U001 HIGH PRODUCT ALARM CLEAR 11-02-18 9:29AM T 1 TANK DIESEL TK#SA002U001 HIGH PRODUCT ALARM ALARM 11-02-18 9:25AM T 1 TANK DIESEL TK#SA002U001 DELIVERY NEEDED CLEAR 11-02-18 9:23AM T 1 TANK DIESEL TK#SA002U001 HIGH WATER WARNING ALARM 11-02-18 9:19AM T 1 TANK DIESEL TK#SA002U001 DELIVERY NEEDED ALARM 11-02-18 9:16AM SYSTEM PRINTER ERROR CLEAR 9-21-18 6:17PM SYSTEM PAPER OUT CLEAR 9-21-18 6:17PM SYSTEM PAPER OUT ALARM 9-21-18 6:17PM SYSTEM PAPER OUT CLEAR 9-21-18 6:17PM SYSTEM PAPER OUT ALARM 9-21-18 6:17PM SYSTEM PAPER OUT CLEAR 9-21-18 6:17PM SYSTEM PAPER OUT ALARM 9-21-18 6:17PM SYSTEM PAPER OUT CLEAR 9-21-18 6:17PM SYSTEM PAPER OUT ALARM 9-21-18 6:17PM SYSTEM PAPER OUT CLEAR 9-21-18 6:17PM SYSTEM PAPER OUT ALARM 9-21-18 6:16PM SYSTEM PRINTER ERROR ALARM 9-21-18 6:16PM T 1 TANK DIESEL TK#SA002U001 DELIVERY NEEDED CLEAR 8-15-18 1:06PM T 1 TANK DIESEL TK#SA002U001 DELIVERY NEEDED ALARM 8-14-18 12:20PM SYSTEM PRINTER ERROR CLEAR 11-07-17 2:01PM SYSTEM PAPER OUT CLEAR 11-07-17 2:00PM I20600 OCT 16, 2020 10:00 AM BKFDCA01 SA002 T-S 1520 20TH ST BAKERSFIELD,CA 93301 661-869-1846 TANK ALARM HISTORY TANK 1 DIESEL TK#SA002U001 LEAK ALARM OCT 11, 2011 6:08 AM OCT 14, 2010 2:44 PM OCT 13, 2010 11:06 AM HIGH WATER ALARM OCT 15, 2020 8:33 AM OCT 23, 2019 9:04 AM NOV 2, 2018 9:19 AM OVERFILL ALARM OCT 15, 2020 9:12 AM OCT 23, 2019 9:12 AM NOV 2, 2018 9:23 AM LOW PRODUCT ALARM OCT 15, 2020 8:29 AM OCT 23, 2019 9:01 AM NOV 2, 2018 9:16 AM SUDDEN LOSS ALARM APR 4, 2010 3:43 PM FEB 19, 2010 10:08 AM FEB 19, 2010 10:05 AM HIGH PRODUCT ALARM OCT 15, 2020 9:12 AM OCT 23, 2019 9:12 AM NOV 2, 2018 9:25 AM INVALID FUEL LEVEL AUG 8, 2017 6:13 AM PROBE OUT OCT 15, 2020 9:12 AM OCT 15, 2020 8:26 AM OCT 23, 2019 9:14 AM HIGH WATER WARNING OCT 15, 2020 8:33 AM OCT 23, 2019 9:04 AM NOV 2, 2018 9:19 AM DELIVERY NEEDED OCT 15, 2020 8:29 AM OCT 23, 2019 9:01 AM NOV 2, 2018 9:16 AM MAX PRODUCT ALARM OCT 15, 2020 9:12 AM OCT 23, 2019 9:13 AM NOV 2, 2018 9:26 AM CSLD INCR RATE WARN DEC 10, 2008 9:38 AM SEP 18, 2008 10:06 AM SEP 18, 2008 6:58 AM LOW TEMP WARNING JAN 22, 2013 9:53 AM APR 4, 2010 3:48 PM TANK 2 DIESEL TK#SA002A002 SETUP DATA WARNING JAN 27, 2012 11:49 AM HIGH WATER ALARM NOV 21, 2016 10:37 AM JAN 27, 2012 11:16 AM FEB 10, 2011 10:26 AM OVERFILL ALARM OCT 23, 2019 10:26 AM NOV 2, 2018 10:38 AM NOV 21, 2016 11:18 AM LOW PRODUCT ALARM OCT 23, 2019 10:24 AM NOV 21, 2016 10:31 AM JAN 7, 2014 9:54 AM SUDDEN LOSS ALARM OCT 12, 2010 8:39 PM FEB 19, 2010 9:55 AM APR 28, 2009 11:13 AM HIGH PRODUCT ALARM OCT 15, 2020 9:46 AM OCT 23, 2019 10:26 AM NOV 2, 2018 10:38 AM INVALID FUEL LEVEL OCT 23, 2019 10:24 AM NOV 21, 2016 10:31 AM JAN 7, 2014 9:55 AM PROBE OUT OCT 15, 2020 9:49 AM OCT 15, 2020 9:41 AM OCT 23, 2019 10:29 AM HIGH WATER WARNING NOV 21, 2016 10:37 AM JAN 27, 2012 11:16 AM FEB 10, 2011 10:26 AM DELIVERY NEEDED OCT 23, 2019 10:24 AM NOV 2, 2018 10:37 AM NOV 7, 2017 1:37 PM MAX PRODUCT ALARM OCT 15, 2020 9:46 AM OCT 23, 2019 10:26 AM NOV 2, 2018 10:38 AM LOW TEMP WARNING DEC 17, 2014 11:26 AM JAN 22, 2013 10:14 AM I30200 OCT 16, 2020 10:00 AM BKFDCA01 SA002 T-S 1520 20TH ST BAKERSFIELD,CA 93301 661-869-1846 LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 FILL SUMP OCT 15, 2020 9:04 AM FUEL ALARM OCT 23, 2019 9:08 AM FUEL ALARM NOV 2, 2018 9:06 AM FUEL ALARM 2 PIPING SUMP OCT 15, 2020 9:08 AM FUEL ALARM OCT 23, 2019 9:19 AM FUEL ALARM NOV 2, 2018 9:10 AM FUEL ALARM 3 DAYTANK RUPTURE BASN OCT 15, 2020 9:39 AM FUEL ALARM OCT 23, 2019 10:19 AM FUEL ALARM NOV 2, 2018 10:25 AM FUEL ALARM 4 DAY TANK ANNULAR OCT 15, 2020 9:35 AM FUEL ALARM OCT 23, 2019 10:16 AM FUEL ALARM NOV 2, 2018 10:29 AM FUEL ALARM 5 ANNULAR UST OCT 15, 2020 9:00 AM FUEL ALARM OCT 23, 2019 9:02 AM FUEL ALARM NOV 2, 2018 9:01 AM FUEL ALARM 6 TRANSITION SUMP OCT 15, 2020 9:17 AM FUEL ALARM OCT 23, 2019 9:24 AM FUEL ALARM NOV 2, 2018 9:30 AM FUEL ALARM 7 REMOTE PUMP CABINET OCT 15, 2020 9:19 AM FUEL ALARM OCT 23, 2019 9:28 AM FUEL ALARM NOV 2, 2018 9:34 AM FUEL ALARM Identification of Inspection Procedures for Overfill Prevention Equipment To Whom It May Concern: Tait Environmental Services, Inc., utilizes the following procedures when conducting Overfill Prevention Equipment Inspections: 1) Drop Tubes with Overfill Prevention Valves a) Verify information based upon Manufacturer installation instructions and follow their inspection procedures. b) If manufacturer information is not available, we conduct the inspection per PEI-RP1200-17, Section 7.1 2) Audible/Visual Alarms a) Verify programming or installation per manufacturer guidelines and test the system per manufacturer specifications. b) If manufacturer information is not available, we conduct the inspection per PEI-1200-17, Section 7.3. 3) Ballfloat Inspections are conducted following the procedures in PEI-RP1200-17, Section 7.2         Identification of Test Procedures for Secondary Containment Testing      To Whom It May Concern:     Tait Environmental Services, Inc., utilizes the following procedures when conducting Secondary  Containment Testing:  1) Containment Sumps, Transition Sumps, UDCs – Tait follows PEI‐RP1200‐17 Section 6.6 for the  accelerated test method. Tait uses the Incon TS‐1000 hydrostatic test equipment following the  attached procedures.  2) Spill Buckets; Direct Bury & Contained in Sumps – Spill buckets contained in sumps are tested  per PEI‐1200‐17, Section 6.2, however Tait Pass/Fail threshold is 0” drop in one hour. Direct Bury  Spill Buckets are test the same as containment sumps per PEI‐1200‐17, Section 6.6.  3) Tank Annular Space – testing is conducted per PEI‐1200‐17, Section 4.2  4) Piping Secondary Containment – Testing is conducted per PEI‐RP1200‐17, Section 5.3    Please consider this letter as our Test Procedure utilized when conducting Secondary Containment  Testing in lieu of either parts or the whole RP1200 document due to copyright infringement.     California Environmental Reporting System: Business Jennifer Pruitt's Account Sign Out Tools Reports Help Submittal Finished: Submittal Finished: AT&T Corp. - SA002/CAK010/USID92203AT&T Corp. - SA002/CAK010/USID92203 Home »Draft Submittal »Submittal Finished (10029370) Print Submittal You have submitted the following elements on 11/12/2020 to Bakersfield City Fire Department • Underground Storage Tanks • Facility Information What's Next? • Return to the Draft Submittal page. • Return to Facility Home. Version 3.05.0004 | Enhancements | CERS Central Diagnostics | Conditions of Use | Privacy Policy | Contact | Help California Environmental Reporting System: Business | © 2020 California Environmental Protection AgencyCERS Technical Support: Request Technical Assistance Unified Program/General Assistance: Contact your local regulator(s) Home Home SubmittalsSubmittals FacilitiesFacilities ComplianceCompliance My BusinessMy Business CERS Help Settings My Busi Page 1 of 2Submittal Finish: CERS Business 11/12/2020https://cersbusiness.calepa.ca.gov/43557/Facility/10029370/Submittal/1753574/Finish CERS Help Settings My Busi Page 2 of 2Submittal Finish: CERS Business 11/12/2020https://cersbusiness.calepa.ca.gov/43557/Facility/10029370/Submittal/1753574/Finish