Loading...
HomeMy WebLinkAboutOVERFILL 2020 Appendix VIII Underground Storage Tank Spill Container Testing Report Form CERS = California Environmental Reporting System, ID = Identification, ICC = International Code Council Page 1 of 2 TYPE OF ACTION ☐ Installation ☐ Repair ☒ 12 Month 1. FACILITY INFORMATION CERS ID 10023802 Test Date 11/19/2020 Facility Name CIRCLE K # 2708605 Facility Address 5600 AUBURN City BAKERSFIELD ZIP Code 93306 2. SERVICE TECHNICIAN INFORMATION Company Performing the Test B&T SERVICE STATION CONTRACTORS Phone 805-929-8944 Mailing Address 630 S FRONTAGE RD NIPOMO, CA. 93444 Service Technician Performing Test MICHAEL MOLACEK Contractor/Tank Tester License Number 902034 ICC Number 9175943 ICC Expiration Date 11/15/2021 3. TRAINING AND CERTIFICATIONS Manufacturer and Test Equipment Training Certifications Expiration Date OPW EVR UST 0178491 06/24/2021 4. TEST PROCEDURE INFORMATION Test Procedures Used Components Tested RP1200 87 , 91 FILL BUCKETS 5. CERTIFICATION BY SERVICE TECHNICIAN CONDUCTING TEST I hereby certify that each spill container was tested in accordance with California Code of Regulations, title 23, division 3, chapter 16, section 2637.1; that required supporting documentation is attached; and all information contained herein is accurate. I understand that test procedures shall be made available upon request by the governing authority. Service Technician Signature Date 11/19/2020 Total # of Pages Underground Storage Tank Spill Container Testing Report Form Additional copies of this page may be attached. Page 2 of 2 6. SPILL CONTAINER DETAILS Test Method Developed by ☐ Manufacturer ☒ Industry Standard ☐ Professional Engineer Test Type ☐ Pressure ☐ Vacuum ☒ Hydrostatic Tank ID 87 91 Spill Container Manufacturer: OPW OPW Method of Cathodic Protection ☒ Nonmetallic ☐ Other ☒ Nonmetallic ☐ Other ☐ Nonmetallic ☐ Other ☐ Nonmetallic ☐ Other Is the spill container minimum capacity five gallons excluding riser volume? ☒ Yes ☐ No* ☒ Yes ☐ No* ☐ Yes ☐ No* ☐ Yes ☐ No* Method to keep spill container empty ☒ Drain ☐ Pump ☐ Other ☒ Drain ☐ Pump ☐ Other ☐ Drain ☐ Pump ☐ Other ☐ Drain ☐ Pump ☐ Other Spill Container Test Results ☒ Pass ☐ Fail ☒ Pass ☐ Fail ☐ Pass ☐ Fail ☐ Pass ☐ Fail Tank ID Spill Container Manufacturer: Method of Cathodic Protection ☐ Nonmetallic ☐ Other ☐ Nonmetallic ☐ Other ☐ Nonmetallic ☐ Other ☐ Nonmetallic ☐ Other Is the spill container minimum capacity five gallons excluding riser volume? ☐ Yes ☐ No* ☐ Yes ☐ No* ☐ Yes ☐ No* ☐ Yes ☐ No* Method to keep spill container empty ☐ Drain ☐ Pump ☐ Other ☐ Drain ☐ Pump ☐ Other ☐ Drain ☐ Pump ☐ Other ☐ Drain ☐ Pump ☐ Other Spill Container Test Results ☐ Pass ☐ Fail ☐ Pass ☐ Fail ☐ Pass ☐ Fail ☐ Pass ☐ Fail 1 8. COMMENTS Describe all answers marked “Other,” “No,” or “Fail” and each proposed remedy. * Mark here if: Spill containers do not have a minimum capacity of five gallons and require replacement.