Loading...
HomeMy WebLinkAboutFMC RESULTS 2020Appendix VI Underground Storage Tank Monitoring System Certification Form CERS = California Environmental Reporting System, GPH = Gallons Per Hour, ID = Identification, ICC = International Code Council, LLD = Line Leak Detector, NA = Not Applicable, SW = Single- Walled, UDC = Under-Dispenser Containment, UST = Underground Storage Tank, VPH = Vacuum/Pressure/Hydrostatic Page 1 of 6 TYPE OF ACTION ☐☐☐☐Installation ☐☐☐☐Repair XXXX12 Month 1. FACILITY INFORMATION CERS ID 10022869 Certification Date 12/16/2020 Facility Name Cirkle K Facility Address 5634 Stine Rd. City Bakersfield ZIP Code 93313 2. SERVICE TECHNICIAN INFORMATION Company Performing the Certification B&T Service Station Contractors Phone 805-929-8944 Mailing Address 630 S. Frontage Rd. Nipomo, CA 93444 Service Technician Performing Test Michael A. Molacek Contractor/Tank Tester License Number 902034 ICC Number 9175943 ICC Expiration Date 11/15/2021 3. TRAINING AND CERTIFICATIONS Manufacturer and Test Equipment Training Certifications Expiration Date Veeder Root TLS 350 technician C27091 10/29/2022 Catastrophic Testing Technician VMI #4640 04/06/2022 4.CERTIFICATION BY SERVICE TECHNICIAN CONDUCTING TEST I hereby certify that the monitoring system is operational in accordance with California Code of Regulations, title 23, division 3, chapter 16, section 2638; that required supporting documentation is attached; and all information contained herein is accurate. Service Technician Signature Date 12/16/2020 Total # of Pages 5.MONITORING SYSTEM AND PROGRAMMING Underground Storage Tank Monitoring System Certification Form Page 2 of 6 A separate Monitoring System Certification Form must be prepared for each control panel. Make of Monitoring System Control Panel Veeder Root Model of Monitoring System Control Panel TLS 350 Software Version Installed 335.00 Attach the post-certification reports if the monitoring system is capable of generating either;XXXXMonitoring System Set-up XXXXAlarm History Report Yes No NA All monitoring equipment is operational per manufacturer’s specifications? XXXX ☐☐☐☐ Secondary containment systems arefree of damage, debris, or liquid? XXXX ☐☐☐☐ Are the audible and visual alarms operational? XXXX ☐☐☐☐ All sensors have been: 1) visually inspected for wiring kinks, breaks andresidual buildup on floats; and 2) tested for functionality and confirmed operational? XXXX ☐☐☐☐ ☐☐☐☐ Are all sensors installed to detect a release at the earliest opportunity in the secondary containment? XXXX ☐☐☐☐ ☐☐☐☐ The monitoring system set-up was reviewed,and proper settings confirmed? XXXX ☐☐☐☐ ☐☐☐☐ Was the monitoring control panel’s backup battery visually inspected, functionally tested, and confirmed operational? XXXX ☐☐☐☐ ☐☐☐☐ Does the flow of fuel stop at the dispenser if a release is detected in the under-dispenser containment? XXXX ☐☐☐☐ ☐☐☐☐ Does the turbine automatically shut down if the piping secondary containment monitoring system fails to operate or is electrically disconnected? XXXX ☐☐☐☐ ☐☐☐☐ Does the turbine automatically shut down if the piping secondary containment monitoring system detects a release?Which sensors initiate positive shut down? (Check all that apply)XSump ☐UDC XXXX ☐☐☐☐ ☐☐☐☐ If monitoring system alarms are relayed to a remote monitoring center, is all communication equipment operational? XXXX ☐☐☐☐ ☐☐☐☐ Describe all answers marked “No” or “Fail”and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 Underground Storage Tank Monitoring System Certification Form Page 3 of 6 6. SENSOR TESTING RESULTS List only sensors tested on date of this certification. List “Sensor ID” as labeled in system programming. Additional copies of this page may be attached to accommodate all sensors tested. Sensor ID Sensor Model Component(s) Monitored Pass Fail L1 409 87 Annular Space XXXX ☐☐☐☐ L2 208 87 STP XXXX ☐☐☐☐ L3 409 91 Annular Space XXXX ☐☐☐☐ ☐☐☐☐ ☐☐☐☐ ☐☐☐☐ ☐☐☐☐ ☐☐☐☐ ☐☐☐☐ ☐☐☐☐ ☐☐☐☐ ☐☐☐☐ ☐☐☐☐ ☐☐☐☐ ☐☐☐☐ ☐☐☐☐ ☐☐☐☐ ☐☐☐☐ ☐☐☐☐ ☐☐☐☐ ☐☐☐☐ ☐☐☐☐ ☐☐☐☐ ☐☐☐☐ ☐☐☐☐ ☐☐☐☐ ☐☐☐☐ ☐☐☐☐ ☐☐☐☐ ☐☐☐☐ ☐☐☐☐ ☐☐☐☐ ☐☐☐☐ ☐☐☐☐ ☐☐☐☐ ☐☐☐☐ ☐☐☐☐ ☐☐☐☐ ☐☐☐☐ ☐☐☐☐ ☐☐☐☐ ☐☐☐☐ ☐☐☐☐ ☐☐☐☐ ☐☐☐☐ Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 L4 208 91 STP X Underground Storage Tank Monitoring System Certification Form Page 4 of 6 7. LINE LEAK DETECTOR TESTING ☐☐☐☐Check this box if line leak detectors ARE NOT installed. (Do not complete this section.) Simulated release rate verified: (Check all that apply.) XXXX3 GPH ☐☐☐☐0.1 GPH☐☐☐☐0.2 GPH Yes No NA Has the testing apparatus been properly calibrated? XXXX ☐☐☐☐ ☐☐☐☐ For emergency generator tank systems, does the LLD create an audible and visual alarm when a leak is detected? ☐☐☐☐ ☐☐☐☐ XXXX For mechanical LLDs, does the LLD restrict the flow through the pipe when a release is detected? XXXX ☐☐☐☐ ☐☐☐☐ For electronic LLDs, does the turbine automatically shut off when a release is detected? ☐☐☐☐ ☐☐☐☐ XXXX For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system is disabled or disconnected? ☐☐☐☐ ☐☐☐☐ XXXX For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system malfunctions or fails a tightness test? ☐☐☐☐ ☐☐☐☐ XXXX For electronic LLDs, have all accessible wiring connections been visually inspected for kinks and breaks? ☐☐☐☐ ☐☐☐☐ XXXX Were all items on the equipment manufacturer’s maintenance checklist completed? XXXX ☐☐☐☐ ☐☐☐☐ Were all LLDs confirmed operational within regulatory requirements? XXXX ☐☐☐☐ ☐☐☐☐ LLD ID LLD Model Lines Monitored Pass Fail T1 LD2200 87 XXXX ☐☐☐☐ T2 LD2200 91 XXXX ☐☐☐☐ ☐☐☐☐ ☐☐☐☐ ☐☐☐☐ ☐☐☐☐ ☐☐☐☐ ☐☐☐☐ ☐☐☐☐ ☐☐☐☐ ☐☐☐☐ ☐☐☐☐ ☐☐☐☐ ☐☐☐☐ ☐☐☐☐ ☐☐☐☐ ☐☐☐☐ ☐☐☐☐ ☐☐☐☐ ☐☐☐☐ ☐☐☐☐ ☐☐☐☐ Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 Underground Storage Tank Monitoring System Certification Form Page 5 of 6 8. IN-TANK GAUGING TESTING XXXXCheck this box if tank gauging is used only for inventory control. ☐☐☐☐Check this box if NO tank gauging equipment is installed. (Do not complete this section if either box is checked.) Yes No NA All wiring has been: 1) visually inspected for kinks, breaks and proper entry and termination; and 2) tested for ground faults? ☐☐☐☐ ☐☐☐☐ ☐☐☐☐ Were all in-tank gauging probes visually inspected for damage and residue buildup to ensure that floats move freely, functionally tested, and confirmed operational? ☐☐☐☐ ☐☐☐☐ ☐☐☐☐ Was accuracy of system’s product level readings tested? ☐☐☐☐ ☐☐☐☐ ☐☐☐☐ Was accuracy of system’s water level readings tested? ☐☐☐☐ ☐☐☐☐ ☐☐☐☐ Were all probes reinstalled properly? ☐☐☐☐ ☐☐☐☐ ☐☐☐☐ Were all items on the equipment manufacturer’s maintenance checklist completed? ☐☐☐☐ ☐☐☐☐ ☐☐☐☐ Probe ID Probe Model Tanks Monitored Pass Fail ☐☐☐☐ ☐☐☐☐ ☐☐☐☐ ☐☐☐☐ ☐☐☐☐ ☐☐☐☐ ☐☐☐☐ ☐☐☐☐ ☐☐☐☐ ☐☐☐☐ ☐☐☐☐ ☐☐☐☐ 9. COMMENTS 10. MONITORING SITE PLAN Describe all answers marked “No” or “Fail” and proposed remedy. List all monitoring equipment either replaced or repaired. < I10100 DEC 16, 2020 11:53 AM CIRCLE K 2701270 5634 STINE RD. BAKERSFIELD, CA 80749873405001 SYSTEM STATUS REPORT PAPER OUT PRINTER ERROR ISD GROSS PRES WARN > < I51700 DEC 16, 2020 11:53 AM SYSTEM TYPE AND LANGUAGE FLAG SYSTEM UNITS U.S. SYSTEM LANGUAGE ENGLISH SYSTEM DATE/TIME FORMAT MON DD YYYY HH:MM:SS xM > < I50F00 DEC 16, 2020 11:53 AM MON DD YYYY HH:MM:SS xM > < I60100 DEC 16, 2020 11:53 AM TANK CONFIGURATION DEVICE LABEL CONFIGURED 1 UNL-REG(005) ON 2 UNL-PREM ON 3 OFF 4 OFF > < I60200 DEC 16, 2020 11:53 AM TANK PRODUCT LABEL TANK PRODUCT LABEL 1 UNL-REG(005) 2 UNL-PREM 3 4 > < I60300 DEC 16, 2020 11:53 AM TANK PRODUCT CODE TANK PRODUCT LABEL 1 UNL-REG(005) A 2 UNL-PREM B 3 3 4 4 > < I60400 DEC 16, 2020 11:53 AM TANK FULL VOLUME TANK PRODUCT LABEL GALLONS 1 UNL-REG(005) 14425 2 UNL-PREM 11849 3 0 4 0 > < I60700 DEC 16, 2020 11:53 AM TANK DIAMETER TANK PRODUCT LABEL INCHES 1 UNL-REG(005) 117.75 2 UNL-PREM 117.75 3 0.00 4 0.00 > < I60900 DEC 16, 2020 11:53 AM TANK THERMAL COEFFICIENT TANK PRODUCT LABEL 1 UNL-REG(005) 0.000700 2 UNL-PREM 0.000700 3 0.000000 4 0.000000 > < I61200 DEC 16, 2020 11:53 AM TANK MANIFOLDED PARTNERS TANK PRODUCT LABEL SIPHON MANIFOLDED TANKS LINE MANIFOLDED TANKS 1 UNL-REG(005) NONE NONE 2 UNL-PREM NONE NONE 3 NONE NONE 4 NONE NONE > < I62100 DEC 16, 2020 11:54 AM TANK LOW PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 UNL-REG(005) 1084 2 UNL-PREM 900 3 0 4 0 > < I62200 DEC 16, 2020 11:54 AM TANK HIGH PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 UNL-REG(005) 12825 2 UNL-PREM 11257 3 0 4 0 > < I62300 DEC 16, 2020 11:54 AM TANK OVERFILL LEVEL LIMIT TANK PRODUCT LABEL GALLONS 1 UNL-REG(005) 12983 2 UNL-PREM 10664 3 0 4 0 > < I62400 DEC 16, 2020 11:54 AM TANK HIGH WATER LEVEL LIMIT TANK PRODUCT LABEL INCHES 1 UNL-REG(005) 2.5 2 UNL-PREM 2.5 > < I62800 DEC 16, 2020 11:54 AM TANK MAXIMUM VOLUME LIMIT TANK PRODUCT LABEL GALLONS 1 UNL-REG(005) 14425 2 UNL-PREM 11849 3 0 4 0 > < I62900 DEC 16, 2020 11:54 AM TANK DELIVERY REQUIRED LIMIT TANK PRODUCT LABEL GALLONS 1 UNL-REG(005) 749 2 UNL-PREM 948 3 0 4 0 > < I70300 DEC 16, 2020 11:54 AM LIQUID TYPE SENSOR LOCATION TYPE 1 87 ANNULAR TRI-STATE (SINGLE FLOAT) 2 87 TURBINE TRI-STATE (SINGLE FLOAT) 3 91 ANNULAR TRI-STATE (SINGLE FLOAT) 4 91 TURBINE TRI-STATE (SINGLE FLOAT) 5 TRI-STATE (SINGLE FLOAT) 6 TRI-STATE (SINGLE FLOAT) 7 TRI-STATE (SINGLE FLOAT) 8 TRI-STATE (SINGLE FLOAT) > < I20600 DEC 16, 2020 11:54 AM CIRCLE K 2701270 5634 STINE RD. BAKERSFIELD, CA 80749873405001 TANK ALARM HISTORY TANK 1 UNL-REG(005) SETUP DATA WARNING OCT 8, 2020 11:23 PM SEP 22, 2020 5:39 AM LOW PRODUCT ALARM SEP 20, 2019 7:37 PM TANK 2 UNL-PREM TANK 5 TANK 6 TANK 7 TANK 8 TANK 9 TANK 10 TANK 11 TANK 12 TANK 13 TANK 14 TANK 15 TANK 16 > < I30200 DEC 16, 2020 11:54 AM CIRCLE K 2701270 5634 STINE RD. BAKERSFIELD, CA 80749873405001 LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 87 ANNULAR DEC 16, 2020 10:37 AM SENSOR OUT ALARM DEC 16, 2020 10:22 AM FUEL ALARM DEC 16, 2020 10:22 AM FUEL ALARM 2 87 TURBINE DEC 16, 2020 10:37 AM SENSOR OUT ALARM DEC 16, 2020 10:20 AM FUEL ALARM DEC 19, 2019 9:30 AM FUEL ALARM 3 91 ANNULAR DEC 16, 2020 10:37 AM SENSOR OUT ALARM DEC 16, 2020 10:16 AM FUEL ALARM DEC 19, 2019 9:40 AM FUEL ALARM 4 91 TURBINE DEC 16, 2020 10:37 AM SENSOR OUT ALARM DEC 16, 2020 10:13 AM FUEL ALARM DEC 19, 2019 9:29 AM FUEL ALARM > < I38200 DEC 16, 2020 11:55 AM > < I90200 DEC 16, 2020 11:55 AM SOFTWARE REVISION LEVEL VERSION 335.00 SOFTWARE# 346335-100-A CREATED - 18.08.27.10.22 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD/APM > < I31600 DEC 16, 2020 11:55 AM CIRCLE K 2701270 5634 STINE RD. BAKERSFIELD, CA 80749873405001 SMART SENSOR ALARM HISTORY REPORT SENSOR LOCATION 1 DISP 1-2 AFM 2 DISP 3-4 AFM MAY 9, 2019 11:52 AM COMMUNICATION ALARM 3 DISP 5-6 AFM 4 DISP 7-8 AFM 5 DISP 1-2 VPS > < I32300 DEC 16, 2020 11:55 AM > < I34200 DEC 16, 2020 11:55 AM > < I34700 DEC 16, 2020 11:55 AM > < I20700 DEC 16, 2020 11:55 AM CIRCLE K 2701270 5634 STINE RD. BAKERSFIELD, CA 80749873405001 TANK LEAK TEST HISTORY T 1:UNL-REG(005) LAST GROSS TEST PASSED: NO TEST PASSED LAST ANNUAL TEST PASSED: NO TEST PASSED FULLEST ANNUAL TEST PASS NO TEST PASSED LAST PERIODIC TEST PASS: NO TEST PASSED FULLEST PERIODIC TEST PASSED EACH MONTH: TEST START TIME HOURS VOLUME % VOLUME TEST TYPE TANK LEAK TEST HISTORY T 2:UNL-PREM LAST GROSS TEST PASSED: NO TEST PASSED LAST ANNUAL TEST PASSED: NO TEST PASSED FULLEST ANNUAL TEST PASS NO TEST PASSED LAST PERIODIC TEST PASS: NO TEST PASSED FULLEST PERIODIC TEST PASSED EACH MONTH: TEST START TIME HOURS VOLUME % VOLUME TEST TYPE > < I31200 DEC 16, 2020 11:55 AM > < I38700 DEC 16, 2020 11:56 AM > < I20300 DEC 16, 2020 11:56 AM CIRCLE K 2701270 5634 STINE RD. BAKERSFIELD, CA 80749873405001 TANK 1 UNL-REG(005) TEST STATUS: OFF LEAK DATA NOT AVAILABLE ON THIS TANK TANK 2 UNL-PREM TEST STATUS: OFF LEAK DATA NOT AVAILABLE ON THIS TANK > < I25100 DEC 16, 2020 11:56 AM CIRCLE K 2701270 5634 STINE RD. BAKERSFIELD, CA 80749873405001 CSLD TEST RESULTS TANK PRODUCT RESULT > < I21300 DEC 16, 2020 11:56 AM CIRCLE K 2701270 5634 STINE RD. BAKERSFIELD, CA 80749873405001 DELIVERY REPORT T 1:UNL-REG(005) INCREASE DATE / TIME GALLONS TC GALLONS WATER TEMP DEG F HEIGHT T 2:UNL-PREM INCREASE DATE / TIME GALLONS TC GALLONS WATER TEMP DEG F HEIGHT > < I31800 DEC 16, 2020 11:56 AM > < I37400 DEC 16, 2020 11:56 AM > < I38900 DEC 16, 2020 11:56 AM > < I11100 DEC 16, 2020 11:56 AM CIRCLE K 2701270 5634 STINE RD. BAKERSFIELD, CA 80749873405001 PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME L 4 STP SUMP 91 TURBINE SENSOR OUT ALARM CLEAR 12-16-20 10:38AM L 3 ANNULAR 91 ANNULAR SENSOR OUT ALARM CLEAR 12-16-20 10:38AM L 2 STP SUMP 87 TURBINE SENSOR OUT ALARM CLEAR 12-16-20 10:38AM L 1 ANNULAR 87 ANNULAR SENSOR OUT ALARM CLEAR 12-16-20 10:38AM L 4 STP SUMP 91 TURBINE SENSOR OUT ALARM ALARM 12-16-20 10:37AM L 3 ANNULAR 91 ANNULAR SENSOR OUT ALARM ALARM 12-16-20 10:37AM L 2 STP SUMP 87 TURBINE SENSOR OUT ALARM ALARM 12-16-20 10:37AM L 1 ANNULAR 87 ANNULAR SENSOR OUT ALARM ALARM 12-16-20 10:37AM L 1 ANNULAR 87 ANNULAR FUEL ALARM CLEAR 12-16-20 10:22AM L 1 ANNULAR 87 ANNULAR FUEL ALARM ALARM 12-16-20 10:22AM L 1 ANNULAR 87 ANNULAR FUEL ALARM CLEAR 12-16-20 10:22AM L 1 ANNULAR 87 ANNULAR FUEL ALARM ALARM 12-16-20 10:22AM L 2 STP SUMP 87 TURBINE FUEL ALARM CLEAR 12-16-20 10:21AM L 2 STP SUMP 87 TURBINE FUEL ALARM ALARM 12-16-20 10:20AM L 3 ANNULAR 91 ANNULAR FUEL ALARM CLEAR 12-16-20 10:17AM L 3 ANNULAR 91 ANNULAR FUEL ALARM ALARM 12-16-20 10:16AM L 4 STP SUMP 91 TURBINE FUEL ALARM CLEAR 12-16-20 10:13AM L 4 STP SUMP 91 TURBINE FUEL ALARM ALARM 12-16-20 10:13AM f 1 OTHER DISP 1-2 AFM CHK VAPOR FLOW MTR CLEAR 10-12-20 9:40AM f 1 OTHER DISP 1-2 AFM CHK VAPOR FLOW MTR ALARM 10-12-20 9:05AM f 1 OTHER DISP 1-2 AFM CHK VAPOR FLOW MTR CLEAR 10-12-20 8:36AM f 1 OTHER DISP 1-2 AFM CHK VAPOR FLOW MTR ALARM 10-07-20 9:05AM L 3 ANNULAR 91 ANNULAR FUEL ALARM CLEAR 12-19-19 9:40AM L 3 ANNULAR 91 ANNULAR FUEL ALARM ALARM 12-19-19 9:40AM L 3 ANNULAR 91 ANNULAR FUEL ALARM CLEAR 12-19-19 9:40AM L 3 ANNULAR 91 ANNULAR FUEL ALARM ALARM 12-19-19 9:39AM L 3 ANNULAR 91 ANNULAR FUEL ALARM CLEAR 12-19-19 9:38AM L 3 ANNULAR 91 ANNULAR FUEL ALARM ALARM 12-19-19 9:38AM L 3 ANNULAR 91 ANNULAR FUEL ALARM CLEAR 12-19-19 9:38AM L 3 ANNULAR 91 ANNULAR FUEL ALARM ALARM 12-19-19 9:38AM L 3 ANNULAR 91 ANNULAR FUEL ALARM CLEAR 12-19-19 9:37AM L 3 ANNULAR 91 ANNULAR FUEL ALARM ALARM 12-19-19 9:37AM L 3 ANNULAR 91 ANNULAR FUEL ALARM CLEAR 12-19-19 9:37AM L 3 ANNULAR 91 ANNULAR FUEL ALARM ALARM 12-19-19 9:36AM L 1 ANNULAR 87 ANNULAR FUEL ALARM CLEAR 12-19-19 9:33AM L 1 ANNULAR 87 ANNULAR FUEL ALARM ALARM 12-19-19 9:32AM L 1 ANNULAR 87 ANNULAR FUEL ALARM CLEAR 12-19-19 9:32AM L 1 ANNULAR 87 ANNULAR FUEL ALARM ALARM 12-19-19 9:32AM L 1 ANNULAR 87 ANNULAR FUEL ALARM CLEAR 12-19-19 9:32AM L 1 ANNULAR 87 ANNULAR FUEL ALARM ALARM 12-19-19 9:32AM L 1 ANNULAR 87 ANNULAR FUEL ALARM CLEAR 12-19-19 9:32AM L 1 ANNULAR 87 ANNULAR FUEL ALARM ALARM 12-19-19 9:32AM L 1 ANNULAR 87 ANNULAR FUEL ALARM CLEAR 12-19-19 9:32AM L 1 ANNULAR 87 ANNULAR FUEL ALARM ALARM 12-19-19 9:31AM L 2 STP SUMP 87 TURBINE FUEL ALARM CLEAR 12-19-19 9:30AM L 2 STP SUMP 87 TURBINE FUEL ALARM ALARM 12-19-19 9:30AM L 4 STP SUMP 91 TURBINE FUEL ALARM CLEAR 12-19-19 9:29AM L 4 STP SUMP 91 TURBINE FUEL ALARM ALARM 12-19-19 9:29AM OTHER ISD GROSS PRES FAIL CLEAR 12-02-19 10:01AM OTHER ISD GROSS PRES FAIL ALARM 12-02-19 9:02AM > < I11200 DEC 16, 2020 11:56 AM CIRCLE K 2701270 5634 STINE RD. BAKERSFIELD, CA 80749873405001 NON-PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME SYSTEM PRINTER ERROR ALARM 12-16-20 11:48AM SYSTEM PAPER OUT ALARM 12-16-20 11:48AM OTHER ISD GROSS PRES WARN ALARM 12-10-20 9:02AM OTHER ISD GROSS PRES WARN CLEAR 12-03-20 9:35AM SYSTEM PRINTER ERROR CLEAR 11-29-20 5:00AM SYSTEM PAPER OUT CLEAR 11-29-20 5:00AM SYSTEM PRINTER ERROR ALARM 11-29-20 5:00AM SYSTEM PAPER OUT ALARM 11-29-20 5:00AM OTHER ISD GROSS PRES WARN ALARM 11-28-20 9:02AM OTHER ISD GROSS PRES WARN CLEAR 11-21-20 11:11AM OTHER ISD GROSS PRES WARN ALARM 11-16-20 9:04AM h 7 OTHER FP7: BLEND3 DEGRD COLLECT WARN CLEAR 11-13-20 9:00AM SYSTEM PRINTER ERROR CLEAR 11-12-20 9:12AM SYSTEM PRINTER ERROR ALARM 11-12-20 9:12AM SYSTEM PRINTER ERROR CLEAR 11-12-20 9:12AM SYSTEM PAPER OUT CLEAR 11-12-20 9:12AM SYSTEM PRINTER ERROR ALARM 11-12-20 9:07AM SYSTEM PAPER OUT ALARM 11-12-20 9:07AM h 7 OTHER FP7: BLEND3 DEGRD COLLECT WARN ALARM 11-12-20 9:03AM h 7 OTHER FP7: BLEND3 DEGRD COLLECT WARN CLEAR 11-11-20 9:00AM h 7 OTHER FP7: BLEND3 DEGRD COLLECT WARN ALARM 11-10-20 9:05AM OTHER ISD GROSS PRES WARN CLEAR 11-09-20 1:11PM OTHER ISD GROSS PRES WARN ALARM 11-07-20 9:04AM h 2 OTHER FP2: BLEND3 GROSS COLLECT WARN CLEAR 10-12-20 9:39AM h 1 OTHER FP1: BLEND3 GROSS COLLECT WARN CLEAR 10-12-20 9:39AM OTHER ISD SENSOR OUT WARN CLEAR 10-12-20 9:39AM OTHER ISD SENSOR OUT WARN ALARM 10-12-20 9:05AM h 2 OTHER FP2: BLEND3 GROSS COLLECT WARN ALARM 10-12-20 9:05AM h 1 OTHER FP1: BLEND3 GROSS COLLECT WARN ALARM 10-12-20 9:05AM OTHER ISD SENSOR OUT WARN CLEAR 10-12-20 8:34AM T 1 TANK UNL-REG(005) SETUP DATA WARNING CLEAR 10-08-20 11:24PM T 1 TANK UNL-REG(005) SETUP DATA WARNING ALARM 10-08-20 11:23PM OTHER ISD SENSOR OUT WARN ALARM 10-07-20 9:05AM T 1 TANK UNL-REG(005) SETUP DATA WARNING CLEAR 9-22-20 5:40AM T 1 TANK UNL-REG(005) SETUP DATA WARNING ALARM 9-22-20 5:39AM SYSTEM PRINTER ERROR CLEAR 9-21-20 11:53PM SYSTEM PAPER OUT CLEAR 9-21-20 11:53PM SYSTEM PRINTER ERROR ALARM 9-21-20 11:53PM SYSTEM PAPER OUT ALARM 9-21-20 11:53PM SYSTEM PRINTER ERROR CLEAR 9-21-20 5:06AM SYSTEM PAPER OUT CLEAR 9-21-20 5:06AM SYSTEM PRINTER ERROR ALARM 9-21-20 5:06AM SYSTEM PAPER OUT ALARM 9-21-20 5:06AM SYSTEM PRINTER ERROR CLEAR 9-21-20 5:06AM SYSTEM PAPER OUT CLEAR 9-21-20 5:06AM SYSTEM PRINTER ERROR ALARM 9-21-20 5:00AM SYSTEM PAPER OUT ALARM 9-21-20 5:00AM OTHER ISD GROSS PRES WARN CLEAR 8-14-20 8:34AM OTHER ISD GROSS PRES WARN ALARM 8-13-20 9:04AM SYSTEM PRINTER ERROR CLEAR 7-17-20 9:21AM > < I11400 DEC 16, 2020 11:57 AM CIRCLE K 2701270 5634 STINE RD. BAKERSFIELD, CA 80749873405001 CLEARED ALARMS REPORT ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME L 4 STP SUMP 91 TURBINE SENSOR OUT ALARM CLEAR 12-16-20 10:38AM L 3 ANNULAR 91 ANNULAR SENSOR OUT ALARM CLEAR 12-16-20 10:38AM L 2 STP SUMP 87 TURBINE SENSOR OUT ALARM CLEAR 12-16-20 10:38AM L 1 ANNULAR 87 ANNULAR SENSOR OUT ALARM CLEAR 12-16-20 10:38AM L 1 ANNULAR 87 ANNULAR FUEL ALARM CLEAR 12-16-20 10:22AM L 1 ANNULAR 87 ANNULAR FUEL ALARM CLEAR 12-16-20 10:22AM L 2 STP SUMP 87 TURBINE FUEL ALARM CLEAR 12-16-20 10:21AM L 3 ANNULAR 91 ANNULAR FUEL ALARM CLEAR 12-16-20 10:17AM L 4 STP SUMP 91 TURBINE FUEL ALARM CLEAR 12-16-20 10:13AM f 1 OTHER DISP 1-2 AFM CHK VAPOR FLOW MTR CLEAR 10-12-20 9:40AM f 1 OTHER DISP 1-2 AFM CHK VAPOR FLOW MTR CLEAR 10-12-20 8:36AM L 3 ANNULAR 91 ANNULAR FUEL ALARM CLEAR 12-19-19 9:40AM L 3 ANNULAR 91 ANNULAR FUEL ALARM CLEAR 12-19-19 9:40AM L 3 ANNULAR 91 ANNULAR FUEL ALARM CLEAR 12-19-19 9:38AM L 3 ANNULAR 91 ANNULAR FUEL ALARM CLEAR 12-19-19 9:38AM L 3 ANNULAR 91 ANNULAR FUEL ALARM CLEAR 12-19-19 9:37AM L 3 ANNULAR 91 ANNULAR FUEL ALARM CLEAR 12-19-19 9:37AM L 1 ANNULAR 87 ANNULAR FUEL ALARM CLEAR 12-19-19 9:33AM L 1 ANNULAR 87 ANNULAR FUEL ALARM CLEAR 12-19-19 9:32AM L 1 ANNULAR 87 ANNULAR FUEL ALARM CLEAR 12-19-19 9:32AM L 1 ANNULAR 87 ANNULAR FUEL ALARM CLEAR 12-19-19 9:32AM L 1 ANNULAR 87 ANNULAR FUEL ALARM CLEAR 12-19-19 9:32AM L 2 STP SUMP 87 TURBINE FUEL ALARM CLEAR 12-19-19 9:30AM L 4 STP SUMP 91 TURBINE FUEL ALARM CLEAR 12-19-19 9:29AM OTHER ISD GROSS PRES FAIL CLEAR 12-02-19 10:01AM OTHER ISD GROSS PRES WARN CLEAR 12-03-20 9:35AM SYSTEM PRINTER ERROR CLEAR 11-29-20 5:00AM SYSTEM PAPER OUT CLEAR 11-29-20 5:00AM OTHER ISD GROSS PRES WARN CLEAR 11-21-20 11:11AM h 7 OTHER FP7: BLEND3 DEGRD COLLECT WARN CLEAR 11-13-20 9:00AM SYSTEM PRINTER ERROR CLEAR 11-12-20 9:12AM SYSTEM PRINTER ERROR CLEAR 11-12-20 9:12AM SYSTEM PAPER OUT CLEAR 11-12-20 9:12AM h 7 OTHER FP7: BLEND3 DEGRD COLLECT WARN CLEAR 11-11-20 9:00AM OTHER ISD GROSS PRES WARN CLEAR 11-09-20 1:11PM h 2 OTHER FP2: BLEND3 GROSS COLLECT WARN CLEAR 10-12-20 9:39AM h 1 OTHER FP1: BLEND3 GROSS COLLECT WARN CLEAR 10-12-20 9:39AM OTHER ISD SENSOR OUT WARN CLEAR 10-12-20 9:39AM OTHER ISD SENSOR OUT WARN CLEAR 10-12-20 8:34AM T 1 TANK UNL-REG(005) SETUP DATA WARNING CLEAR 10-08-20 11:24PM T 1 TANK UNL-REG(005) SETUP DATA WARNING CLEAR 9-22-20 5:40AM SYSTEM PRINTER ERROR CLEAR 9-21-20 11:53PM SYSTEM PAPER OUT CLEAR 9-21-20 11:53PM SYSTEM PRINTER ERROR CLEAR 9-21-20 5:06AM SYSTEM PAPER OUT CLEAR 9-21-20 5:06AM SYSTEM PRINTER ERROR CLEAR 9-21-20 5:06AM SYSTEM PAPER OUT CLEAR 9-21-20 5:06AM OTHER ISD GROSS PRES WARN CLEAR 8-14-20 8:34AM SYSTEM PRINTER ERROR CLEAR 7-17-20 9:21AM > < I40200 DEC 16, 2020 11:57 AM >