021,725,1*6<67(0&(57,),&$7,21)2503DJHRI
7KLVIRUPPXVWEHXVHGWRGRFXPHQWWHVWLQJDQGVHUYLFLQJRIXQGHUJURXQGVWRUDJHWDQN867PRQLWRULQJHTXLSPHQW$FRS\
RIWKLVIRUPPXVWEHSURYLGHGWRWKH867RZQHURURSHUDWRU7KHRZQHURURSHUDWRUPXVWVXEPLWDFRS\RIWKLVIRUPWRWKHORFDO
DJHQF\UHJXODWLQJWKH867VZLWKLQGD\VRIWKHGDWHRIWKHPRQLWRULQJV\VWHPFHUWLILFDWLRQ
, )$&,/,7<,1)250$7,21
&(56,''DWHRI0RQLWRULQJ6\VWHP&HUWLILFDWLRQ
%XVLQHVV1DPH(Same as Facility Name or DBA-Doing Business As)
%XVLQHVV6LWH$GGUHVV &LW\ =,3&RGH
,, 81'(5*5281'6725$*(7$1.6(59,&(7(&+1,&,$1,1)250$7,21
1DPHRI&RPSDQ\3HUIRUPLQJWKH&HUWLILFDWLRQ 3KRQH
0DLOLQJ$GGUHVV
1DPHRI8676HUYLFH7HFKQLFLDQ3HUIRUPLQJWKH&HUWLILFDWLRQ(Print as shown on the ICC Certification)
&RQWUDFWRU7DQN7HVWHU/LFHQVH ,&&&HUWLILFDWLRQ ,&&&HUWLILFDWLRQ([SLUDWLRQ'DWH
0RQLWRULQJ6\VWHP7UDLQLQJDQG&HUWLILFDWLRQV(List all applicable certifications.) ([SLUDWLRQ'DWH
,,, 5(68/762)7(67,1*6(59,&,1*
Indicate and attach the following reports if the monitoring equipment is capable of generating either.<11$0RQLWRULQJ6\VWHP6HWXS$ODUP+LVWRU\5HSRUW
:DVDQ\PRQLWRULQJHTXLSPHQWUHSODFHG"
(If “Yes,” identify the specific devices replaced and list the manufacturer and model for all replacement parts in section IV below.)
:DVGDPDJHGHEULVRUOLTXLGIRXQGLQVLGHDQ\VHFRQGDU\FRQWDLQPHQWV\VWHPV"
(If “Yes,” describe what was found in section IV below.)
,VDOOPRQLWRULQJHTXLSPHQWRSHUDWLRQDOSHUPDQXIDFWXUHU¶VVSHFLILFDWLRQV"
(If “No,” describe why in section IV below.)
,9 &200(176
If directed to use this section, describe how and when the issues were or will be corrected.
9 &(57,),&$7,21%<8676(59,&(7(&+1,&,$1&21'8&7,1*7+,67(67,1*
,KHUHE\FHUWLI\WKDWWKHHTXLSPHQWLGHQWLILHGLQWKLVGRFXPHQWZDVLQVSHFWHGVHUYLFHGLQDFFRUGDQFHZLWK&DOLIRUQLD&RGHRI
5HJXODWLRQV7LWOH'LYLVLRQ&KDSWHU6HFWLRQDQGDOOLQIRUPDWLRQFRQWDLQHGKHUHLQLVWUXHDQGDFFXUDWH$WWDFKHGWR
WKLVFHUWLILFDWLRQLVLQIRUPDWLRQHJPDQXIDFWXUHUV
FKHFNOLVWVPRQLWRULQJV\VWHPVHWXSDODUPKLVWRU\UHSRUWHWFQHFHVVDU\
WRYHULI\WKDWWKLVLQIRUPDWLRQDQGWKHVLWHSODQVKRZLQJWKHOD\RXWRI867V\VWHPLVFRPSOHWHDQGDFFXUDWH
8676HUYLFH7HFKQLFLDQ6LJQDWXUH
%XLOGLQJ
10123120 11/15/2018
Sparkling Image Car Wash
2301 H Street Bakersfield 93301
16250 Meacham Road, Bakersfield, CA 93314
Frank Amestoy
804904 8374998 11/14/2019
Veeder-root B64403 8/3/2020
Franklin fueling 1008973709 4/12/2019
Confidence UST Services, Inc. (800) 339-9930
,' ,GHQWLILFDWLRQ6: 6LQJOH:DOOHG93+ 9DFXXP3UHVVXUH+\GURVWDWLF//' /LQH/HDN'HWHFWRU
81 ZZZXQLGRFVRUJ 5HY
81'(5*5281'6725$*(7$1.
021,725,1*6<67(0&(57,),&$7,21)2503DJHRI
9, ,19(1725<2)(48,30(17&(57,),('
A separate Monitoring System Certification Form must be prepared for each monitoring system control panel.
0DNHRI0RQLWRULQJ6\VWHP&RQWURO3DQHO
0RGHORI0RQLWRULQJ6\VWHP&RQWURO3DQHO
6RIWZDUH9HUVLRQ,QVWDOOHG
Check the appropriate boxes to indicate specific equipment inspected/serviced.
0RQLWRULQJ'HYLFH8VHG'HYLFH0RGHO0RQLWRULQJ'HYLFH8VHG'HYLFH0RGHO
7$1.,'
(By tank number, stored product, etc.)
7$1.,'
(By tank number, stored product, etc.)
,Q7DQN*DXJLQJ(SW Tank),Q7DQN*DXJLQJ(SW Tank)
$QQXODU6SDFHRU9DXOW6HQVRU$QQXODU6SDFHRU9DXOW6HQVRU
93+6HQVRU93+6HQVRU
3URGXFW3LSLQJ3URGXFW3LSLQJ
0HFKDQLFDO//'0HFKDQLFDO//'
(OHFWURQLF//'(OHFWURQLF//'
93+6HQVRU3LSLQJ93+6HQVRU3LSLQJ
6XPS6HQVRU6XPS6HQVRU
93+6HQVRU6XPS93+6HQVRU6XPS
)LOO3LSLQJ)LOO3LSLQJ
93+6HQVRU3LSLQJ93+6HQVRU3LSLQJ
6XPS6HQVRU6XPS6HQVRU
93+6HQVRU6XPS93+6HQVRU6XPS
9HQW3LSLQJ9HQW3LSLQJ
93+6HQVRU3LSLQJ93+6HQVRU3LSLQJ
6XPS6HQVRU6XPS6HQVRU
93+6HQVRU6XPS93+6HQVRU6XPS
9DSRU5HFRYHU\3LSLQJ9DSRU5HFRYHU\3LSLQJ
93+6HQVRU3LSLQJ93+6HQVRU3LSLQJ
6XPS6HQVRU6XPS6HQVRU
93+6HQVRU6XPS93+6HQVRU6XPS
0RQLWRULQJ'HYLFH8VHG
'HYLFH0RGHO0RQLWRULQJ'HYLFH8VHG
'HYLFH0RGHO
7$1.,'
(By tank number, stored product, etc.)
7$1.,'
(By tank number, stored product, etc.)
,Q7DQN*DXJLQJ(SW Tank),Q7DQN*DXJLQJ(SW Tank)
$QQXODU6SDFHRU9DXOW6HQVRU$QQXODU6SDFHRU9DXOW6HQVRU
93+6HQVRU93+6HQVRU
3URGXFW3LSLQJ3URGXFW3LSLQJ
0HFKDQLFDO//'0HFKDQLFDO//'
(OHFWURQLF//'(OHFWURQLF//'
93+6HQVRU3LSLQJ93+6HQVRU3LSLQJ
6XPS6HQVRU6XPS6HQVRU
93+6HQVRU6XPS93+6HQVRU6XPS
)LOO3LSLQJ)LOO3LSLQJ
93+6HQVRU3LSLQJ93+6HQVRU3LSLQJ
6XPS6HQVRU6XPS6HQVRU
93+6HQVRU6XPS93+6HQVRU6XPS
9HQW3LSLQJ9HQW3LSLQJ
93+6HQVRU3LSLQJ93+6HQVRU3LSLQJ
6XPS6HQVRU6XPS6HQVRU
93+6HQVRU6XPS93+6HQVRU6XPS
9DSRU5HFRYHU\3LSLQJ9DSRU5HFRYHU\3LSLQJ
93+6HQVRU3LSLQJ93+6HQVRU3LSLQJ
6XPS6HQVRU6XPS6HQVRU
93+6HQVRU6XPS93+6HQVRU6XPS
Veeder-root TLS-350 330.01
T1: 87 12,000
84390-107
Mosier brothers vacuum sensor
FX1V
794380-208
T2: 91 12,000
84390-107
Mosier brothers vacuum sensor
FX1V
794380-208
T3: Diesel 12,000
84390-107
Mosier brothers vacuum sensor
FX1DV
794380-208
,' ,GHQWLILFDWLRQ93+ 9DFXXP3UHVVXUH+\GURVWDWLF8'& 8QGHU'LVSHQVHU&RQWDLQPHQW
81 ZZZXQLGRFVRUJ 5HY
81'(5*5281'6725$*(7$1.
021,725,1*6<67(0&(57,),&$7,21)2503DJHRI
0RQLWRULQJ'HYLFH8VHG'HYLFH0RGHO0RQLWRULQJ'HYLFH8VHG'HYLFH0RGHO
9(1775$16,7,216803,'9(1775$16,7,216803,'
6XPS6HQVRU6XPS6HQVRU
93+6HQVRU93+6HQVRU
8'&,'8'&,'
(OHFWURQLF6HQVRU(OHFWURQLF6HQVRU
0HFKDQLFDO'HYLFH0HFKDQLFDO'HYLFH
93+6HQVRU93+6HQVRU
8'&,'8'&,'
(OHFWURQLF6HQVRU(OHFWURQLF6HQVRU
0HFKDQLFDO'HYLFH0HFKDQLFDO'HYLFH
93+6HQVRU93+6HQVRU
8'&,'8'&,'
(OHFWURQLF6HQVRU(OHFWURQLF6HQVRU
0HFKDQLFDO'HYLFH0HFKDQLFDO'HYLFH
93+6HQVRU93+6HQVRU
8'&,'8'&,'
(OHFWURQLF6HQVRU(OHFWURQLF6HQVRU
0HFKDQLFDO'HYLFH0HFKDQLFDO'HYLFH
93+6HQVRU93+6HQVRU
2WKHU0RQLWRUHG&RPSRQHQW,'2WKHU0RQLWRUHG&RPSRQHQW,'
2WKHU(Specify in section VII.)2WKHU(Specify in section VII.)
2WKHU0RQLWRUHG&RPSRQHQW,'2WKHU0RQLWRUHG&RPSRQHQW,'
2WKHU(Specify in section VII.)2WKHU(Specify in section VII.)
2WKHU0RQLWRUHG&RPSRQHQW,'2WKHU0RQLWRUHG&RPSRQHQW,'
2WKHU(Specify in section VII.)2WKHU(Specify in section VII.)
Include information for every underground storage tank component monitored by this monitoring system control panel. If the monitoring system
control panel monitors more components than this form accommodates, additional copies of these pages may be attached.
9,, &200(176
Use this section to provide additional comments about the inventory of the equipment certified.
1/2
794380-208
3/4
794380-208
5/6
794380-208
7/8
794380-208
9/10
794380-208
11/12
794380-208
13/14
794380-208
15/16
794380-208
< <HV1 1R1$ 1RW$SSOLFDEOH
81 ZZZXQLGRFVRUJ 5HY
81'(5*5281'6725$*(7$1.
021,725,1*6<67(0&(57,),&$7,21)2503DJHRI
9,,, 021,725,1*6<67(0$1'352*5$00,1*
This section must be completed if a monitoring panel is used to perform leak detection monitoring.<11$
$UHWKHYLVXDODQGDXGLEOHDODUPVRSHUDWLRQDO"
:HUHDOOVHQVRUVYLVXDOO\LQVSHFWHGIRUNLQNVDQGEUHDNVLQWKHFDEOHVDQGIRUUHVLGXDOEXLOGXSWRHQVXUHWKDWIORDWVPRYHIUHHO\
IXQFWLRQDOO\WHVWHGDQGFRQILUPHGRSHUDWLRQDO"
:HUHDOOVHQVRUVLQVWDOOHGDWORZHVWSRLQWRIVHFRQGDU\FRQWDLQPHQWDQGSRVLWLRQHGVRWKDWRWKHUHTXLSPHQWZLOOQRWLQWHUIHUHZLWK
WKHLUSURSHURSHUDWLRQ"
:DVPRQLWRULQJV\VWHPVHWXSUHYLHZHGWRHQVXUHSURSHUVHWWLQJV"
:DVWKHPRQLWRULQJSDQHO¶VEDFNXSEDWWHU\YLVXDOO\LQVSHFWHGIXQFWLRQDOO\WHVWHGDQGFRQILUPHGRSHUDWLRQDO"
'RHVWKHIORZRIIXHOVWRSDWWKHGLVSHQVHULIDOHDNLVGHWHFWHGLQWKHXQGHUGLVSHQVHUFRQWDLQPHQW"
'RHVWKHWXUELQHDXWRPDWLFDOO\VKXWGRZQLIWKHSLSLQJVHFRQGDU\FRQWDLQPHQWPRQLWRULQJV\VWHPIDLOVWRRSHUDWHRULVHOHFWULFDOO\
GLVFRQQHFWHG"
'RHVWKHWXUELQHDXWRPDWLFDOO\VKXWGRZQLIWKHSLSLQJVHFRQGDU\FRQWDLQPHQWPRQLWRULQJV\VWHPGHWHFWVDOHDN"
:KLFKVHQVRUVLQLWLDWHSRVLWLYHVKXWGRZQ"(Check all that apply.)6XPS8QGHU'LVSHQVHU&RQWDLQPHQW
,IDODUPVDUHUHOD\HGWRDUHPRWHPRQLWRULQJVWDWLRQLVDOOFRPPXQLFDWLRQVHTXLSPHQWHJPRGHPRSHUDWLRQDO"
For any answer of “N” above, describe in Section IX how and when these deficiencies were or will be corrected.
,; &200(176
; ,17$1.*$8*,1*7(67,1*
&KHFNWKLVER[LIWDQNJDXJLQJLVXVHGRQO\IRULQYHQWRU\FRQWURO(Do not complete this section.)
<11$&KHFNWKLVER[LI12WDQNJDXJLQJHTXLSPHQWLVLQVWDOOHG (Do not complete this section.)
This section must be completed if in-tank gauging is used to perform leak detection monitoring.
+DVDOOLQSXWZLULQJEHHQLQVSHFWHGIRUNLQNVDQGEUHDNVLQWKHFDEOHVDQGIRUSURSHUHQWU\DQGWHUPLQDWLRQLQFOXGLQJWHVWLQJIRU
JURXQGIDXOWV"
:HUHDOOLQWDQNJDXJLQJSUREHVYLVXDOO\LQVSHFWHGIRUGDPDJHDQGUHVLGXHEXLOGXSWRHQVXUHWKDWIORDWVPRYHIUHHO\IXQFWLRQDOO\
WHVWHGDQGFRQILUPHGRSHUDWLRQDO"
:DVDFFXUDF\RIV\VWHP¶VSURGXFWOHYHOUHDGLQJVWHVWHG"
:DVDFFXUDF\RIV\VWHP¶VZDWHUOHYHOUHDGLQJVWHVWHG"
:HUHDOOSUREHVUHLQVWDOOHGSURSHUO\"
:HUHDOOLWHPVRQWKHHTXLSPHQWPDQXIDFWXUHU¶VPDLQWHQDQFHFKHFNOLVWFRPSOHWHG"
For any answer of “N” above, describe in Section XI how and when these deficiencies were or will be corrected.
;, &200(176
Sensors in 87STP/91 STP were not installed at the lowest point. I made hangers and install them at lowest point on product side.
*3+ *DOORQV3HU+RXU< <HV1 1R1$ 1RW$SSOLFDEOH93+ 9DFXXP3UHVVXUH+\GURVWDWLF,' ,GHQWLILFDWLRQ
81 ZZZXQLGRFVRUJ5HY
81'(5*5281'6725$*(7$1.
021,725,1*6<67(0&(57,),&$7,21)2503DJHRI
;,, /,1(/($.'(7(&7257(67,1*
&KHFNWKLVER[LIOLQHOHDNGHWHFWRUV//'DUH127LQVWDOOHG(Do not complete this section.)<11$This section must be completed if LLDs are installed.
:DVDOHDNVLPXODWHGWRYHULI\//'SHUIRUPDQFH"
(Check all that apply.)6LPXODWHGOHDNUDWHYHULILHG*3+*3+*3+
:DVWKHWHVWLQJDSSDUDWXVSURSHUO\FDOLEUDWHG"
)RUHPHUJHQF\JHQHUDWRUWDQNV\VWHPVGRHVWKH//'FUHDWHDQDXGLEOHDQGYLVXDODODUPZKHQDOHDNLVGHWHFWHG"
)RUPHFKDQLFDO//'VGRHVWKH//'UHVWULFWWKHIORZWKURXJKWKHSLSHZKHQDOHDNLVGHWHFWHG"
)RUHOHFWURQLF//'VGRHVWKHWXUELQHDXWRPDWLFDOO\VKXWRIIZKHQDOHDNLVGHWHFWHG"
)RUHOHFWURQLF//'VGRHVWKHWXUELQHDXWRPDWLFDOO\VKXWRIILIDQ\SRUWLRQRIWKHPRQLWRULQJV\VWHPLVGLVDEOHGRUGLVFRQQHFWHG"
)RUHOHFWURQLF//'VGRHVWKHWXUELQHDXWRPDWLFDOO\VKXWRIILIDQ\SRUWLRQRIWKHPRQLWRULQJV\VWHPPDOIXQFWLRQVRUIDLOVDWHVW"
)RUHOHFWURQLF//'VKDYHDOODFFHVVLEOHZLULQJFRQQHFWLRQVEHHQYLVXDOO\LQVSHFWHGIRUNLQNVDQGEUHDNV"
:HUHDOOLWHPVRQWKHHTXLSPHQWPDQXIDFWXUHU¶VPDLQWHQDQFHFKHFNOLVWFRPSOHWHG"
:HUHDOO//'VFRQILUPHGRSHUDWLRQDOZLWKLQUHJXODWRU\UHTXLUHPHQWV"
For any answer of “N” above, describe in Section XIII how and when these issues were or will be corrected.
;,,, &200(176
;,9 9$&88035(6685(+<'5267$7,&021,725,1*(48,30(177(67,1*
&KHFNWKLVER[LI93+PRQLWRULQJLV127XVHG(Do not complete this section.)
This section must be completed if VPH monitoring is used to perform leak detection monitoring.
6\VWHP7\SH0DUNDOOWKDWDSSO\9DFXXP3UHVVXUH+\GURVWDWLF
6HQVRU,'&RPSRQHQW60RQLWRUHG%\7KLV6HQVRU 6HQVRU)XQFWLRQDOLW\
7HVW
,QWHUVWLWLDO&RPPXQLFDWLRQ
7HVW
3DVV )DLO 3DVV )DLO
3DVV)DLO3DVV)DLO
3DVV)DLO3DVV)DLO
3DVV)DLO3DVV)DLO
3DVV)DLO3DVV)DLO
3DVV)DLO3DVV)DLO
3DVV)DLO3DVV)DLO
3DVV)DLO3DVV)DLO
3DVV)DLO3DVV)DLO
3DVV)DLO3DVV)DLO
3DVV)DLO3DVV)DLO
3DVV)DLO3DVV)DLO
+RZZDVLQWHUVWLWLDOFRPPXQLFDWLRQYHULILHG"6LPXODWHG/HDNDW)DU(QGVRIWKH,QWHUVWLWLDO6SDFH9LVXDO,QVSHFWLRQ
2WKHU(Describe the method in section XV below.)*DXJH
:DVWKHYDFXXPRUSUHVVXUHUHVWRUHGWRRSHUDWLQJOHYHOVLQDOOLQWHUVWLWLDOVSDFHV"<HV1R(Describe the reason in section XV below.)
For any answer of “Fail” above, describe in Section XV how and when these issues were or will be corrected.
;9 &200(176
L12: 87 annular
L13: 91 annular
L14: Diesel annular
Held vacuum on annular side, released vacuum to gauge and to tubing side. when re-connected annular space to tubing and gauge vacuum came back to
normal. verified communication
Sparkling chevron setup
Responses Received:
200
286917 SPARKLING IMA
2301 H ST.
BAKERSFIELD,CA 93301
661-324-8455
NOV 15, 2018 9:08 AM
TANK PRODUCT GALLONS INCHES WATER DEG F ULLAGE
1 UNLEADED 87 10549 78.87 1.0 65.1 1451
2 SUPREME 91 6243 49.52 0.0 66.0 5757
3 DIESEL 2797 27.21 0.0 82.8 9203
I90500
NOV 15, 2018 9:08 AM
SOFTWARE REVISION LEVEL
VERSION 330.01
SOFTWARE# 346330-100-B
CREATED - 10.07.23.17.25
S-MODULE# 330160-004-a
SYSTEM FEATURES:
PERIODIC IN-TANK TESTS
ANNUAL IN-TANK TESTS
CSLD
BIR
FUEL MANAGER
ISD
PLLD
0.10 AUTO
0.20 REPETITIV
WPLLD
0.10 AUTO
0.20 REPETITIV
I50500
NOV 15, 2018 9:08 AM
SYSTEM TYPE AND LANGUAGE FLAG
SYSTEM UNITS
U.S.
SYSTEM LANGUAGE
ENGLISH
SYSTEM DATE/TIME FORMAT
MON DD YYYY HH:MM:SS xM
I50201
NOV 15, 2018 9:08 AM
SHIFT TIME 1 : 12:00 AM
I50202
NOV 15, 2018 9:08 AM
SHIFT TIME 2 : 6:00 AM
I50203
NOV 15, 2018 9:08 AM
SHIFT TIME 3 : 12:00 PM
I50204
NOV 15, 2018 9:08 AM
SHIFT TIME 4 : 6:00 PM
I54600
NOV 15, 2018 9:08 AM
TANK PER TST NEEDED WRN: DISABLED
I54900
NOV 15, 2018 9:08 AM
TANK ANN TST NEEDED WRN: DISABLED
I55300
NOV 15, 2018 9:08 AM
LINE RE-ENABLE METHOD
PASS LINE TEST
I55600
NOV 15, 2018 9:08 AM
LINE PER TST NEEDED WRN: DISABLED
I55900
NOV 15, 2018 9:08 AM
LINE ANN TST NEEDED WRN: DISABLED
I50D00
NOV 15, 2018 9:08 AM
PRINT TC VOLUMES
ENABLED
I50E00
NOV 15, 2018 9:08 AM
TEMP COMPENSATION
VALUE (DEG F ): 60.0
I60B00
NOV 15, 2018 9:08 AM
STICK HEIGHT OFFSET ENABLE STATUS
DISABLED
I51400
NOV 15, 2018 9:08 AM
H-PROTOCOL DATA FORMAT
HEIGHT
I51A01
NOV 15, 2018 9:08 AM
DAYLIGHT SAVING TIME
ENABLED OFF
I51B00
NOV 15, 2018 9:08 AM
DAYLIGHT SAVING TIME
START DATE MAR WEEK 2 SUN 2:00 AM
END DATE NOV WEEK 1 SUN 2:00 AM
I51600
NOV 15, 2018 9:08 AM
RE-DIRECT LOCAL PRINTOUT
DISABLED
I50400
NOV 15, 2018 9:08 AM
232 SECURITY CODE
PORT SECURITY CODE STATUS
1 000000 DISABLED
2 000000 DISABLED
3 000000 DISABLED
4 000000 DISABLED
5 000000 DISABLED
6 000000 DISABLED
I21900
NOV 15, 2018 9:08 AM
TANK CHART SECURITY
DISABLED
I5BD00
NOV 15, 2018 9:09 AM
CUSTOM ALARM LABELS
DISABLED
I56000
NOV 15, 2018 9:09 AM
MASS/DENSITY
DISABLED
I88101
NOV 15, 2018 9:09 AM
PORT SETTINGS:
COMM BOARD : 1 (EDIM )
RS-232 SECURITY
CODE : DISABLED
I88102
NOV 15, 2018 9:09 AM
PORT SETTINGS:
COMM BOARD : 2 (RS-232)
BAUD RATE : 9600
PARITY : NONE
STOP BIT : 1 STOP
DATA LENGTH: 8 DATA
RS-232 SECURITY
CODE : DISABLED
I88103
NOV 15, 2018 9:09 AM
PORT SETTINGS:
COMM BOARD : 3 (S-SAT )
BAUD RATE : 9600
PARITY : NONE
STOP BIT : 1 STOP
DATA LENGTH: 8 DATA
RS-232 SECURITY
CODE : DISABLED
DTR NORMAL STATE: HIGH
I88104
NOV 15, 2018 9:09 AM
I88105
NOV 15, 2018 9:09 AM
I88106
NOV 15, 2018 9:09 AM
I52000
NOV 15, 2018 9:09 AM
RECEIVER AUTO DIAL TYPE & START TIME
RCVR LOCATION LABEL DIAL TYPE START TIME
1 ON DATE OCT 19, 2015 6:14 AM
2 ON DATE OCT 19, 2015 6:14 AM
3 ON DATE OCT 19, 2015 6:14 AM
4 ON DATE OCT 19, 2015 6:14 AM
5 ON DATE OCT 19, 2015 6:14 AM
6 ON DATE OCT 19, 2015 6:14 AM
7 ON DATE OCT 19, 2015 6:14 AM
8 VEEDER ROOT (FMS) ON DATE JUL 26, 2017 10:38 AM
I60100
NOV 15, 2018 9:09 AM
TANK CONFIGURATION
DEVICE LABEL CONFIGURED
1 UNLEADED 87 ON
2 SUPREME 91 ON
3 DIESEL ON
4 OFF
I60200
NOV 15, 2018 9:09 AM
TANK PRODUCT LABEL
TANK PRODUCT LABEL
1 UNLEADED 87
2 SUPREME 91
3 DIESEL
4
I60300
NOV 15, 2018 9:09 AM
TANK PRODUCT CODE
TANK PRODUCT LABEL
1 UNLEADED 87 1
2 SUPREME 91 2
3 DIESEL 3
4 4
I60900
NOV 15, 2018 9:09 AM
TANK THERMAL COEFFICIENT
TANK PRODUCT LABEL
1 UNLEADED 87 0.000700
2 SUPREME 91 0.000700
3 DIESEL 0.000450
4 0.000000
I60700
NOV 15, 2018 9:09 AM
TANK DIAMETER
TANK PRODUCT LABEL INCHES
1 UNLEADED 87 96.00
2 SUPREME 91 96.00
3 DIESEL 96.00
4 0.00
I60A00
NOV 15, 2018 9:09 AM
TANK FULL VOLUME
TANK PRODUCT LABEL TANK PROFILE GALLONS 1 UNLEADED 87
1 PT 12000 2 SUPREME 91 1 PT 12000 3 DIESEL
1 PT 12000 4 1 PT 0
I60400
NOV 15, 2018 9:09 AM
TANK FULL VOLUME
TANK PRODUCT LABEL GALLONS
1 UNLEADED 87 12000
2 SUPREME 91 12000
3 DIESEL 12000
4 0
I60500
NOV 15, 2018 9:09 AM
TANK 4 POINT VOLUMES
TANK PRODUCT LABEL GALLONS
1 UNLEADED 87 12000 0 0 0
2 SUPREME 91 12000 0 0 0
3 DIESEL 12000 0 0 0
4 0 0 0 0
I60600
NOV 15, 2018 9:09 AM
TANK 20 POINT VOLUMES
TANK PRODUCT LABEL GALLONS
1 UNLEADED 87 12000 0 0 0
0 0 0 0
0 0 0 0
0 0 0 0
0 0 0 0
2 SUPREME 91 12000 0 0 0
0 0 0 0
0 0 0 0
0 0 0 0
0 0 0 0
3 DIESEL 12000 0 0 0
0 0 0 0
0 0 0 0
0 0 0 0
0 0 0 0
4 0 0 0 0
0 0 0 0
0 0 0 0
0 0 0 0
0 0 0 0
I61500
NOV 15, 2018 9:09 AM
TANK PRODUCT LABEL METER DATA
1 UNLEADED 87 NO
2 SUPREME 91 NO
3 DIESEL NO
4 NO
I62F00
NOV 15, 2018 9:09 AM
MAG PROBE FLOAT SIZE
TANK PRODUCT LABEL FLOAT SIZE:
1 UNLEADED 87 4.0 IN.
2 SUPREME 91 4.0 IN.
3 DIESEL 4.0 IN.
I62700
NOV 15, 2018 9:09 AM
TANK HIGH WATER WARNING LIMIT
TANK PRODUCT LABEL INCHES
1 UNLEADED 87 2.0
2 SUPREME 91 2.0
3 DIESEL 2.0
9999FF1B
I62400
NOV 15, 2018 9:09 AM
TANK HIGH WATER LEVEL LIMIT
TANK PRODUCT LABEL INCHES
1 UNLEADED 87 3.0
2 SUPREME 91 3.0
3 DIESEL 3.0
I62800
NOV 15, 2018 9:09 AM
TANK MAXIMUM VOLUME LIMIT
TANK PRODUCT LABEL GALLONS
1 UNLEADED 87 12000
2 SUPREME 91 12000
3 DIESEL 12000
4 0
I62300
NOV 15, 2018 9:09 AM
TANK OVERFILL LEVEL LIMIT
TANK PRODUCT LABEL GALLONS
1 UNLEADED 87 10800
2 SUPREME 91 10800
3 DIESEL 10800
4 0
I62200
NOV 15, 2018 9:09 AM
TANK HIGH PRODUCT LIMIT
TANK PRODUCT LABEL GALLONS
1 UNLEADED 87 11400
2 SUPREME 91 11400
3 DIESEL 11400
4 0
I62900
NOV 15, 2018 9:09 AM
TANK DELIVERY REQUIRED LIMIT
TANK PRODUCT LABEL GALLONS
1 UNLEADED 87 1200
2 SUPREME 91 1200
3 DIESEL 1200
4 0
I62100
NOV 15, 2018 9:09 AM
TANK LOW PRODUCT LIMIT
TANK PRODUCT LABEL GALLONS
1 UNLEADED 87 451
2 SUPREME 91 451
3 DIESEL 451
4 0
I62600
NOV 15, 2018 9:09 AM
TANK LEAK ALARM LIMIT
TANK PRODUCT LABEL GALLONS
1 UNLEADED 87 99
2 SUPREME 91 99
3 DIESEL 99
4 99
I62500
NOV 15, 2018 9:09 AM
TANK SUDDEN LOSS LIMIT
TANK PRODUCT LABEL GALLONS
1 UNLEADED 87 99
2 SUPREME 91 99
3 DIESEL 99
4 99
I60800
NOV 15, 2018 9:09 AM
TANK TILT
TANK PRODUCT LABEL INCHES
1 UNLEADED 87 -3.00
2 SUPREME 91 -2.00
3 DIESEL 0.00
4 0.00
I60B00
NOV 15, 2018 9:09 AM
STICK HEIGHT OFFSET ENABLE STATUS
DISABLED
I60C00
NOV 15, 2018 9:09 AM
TANK STICK HEIGHT OFFSET
TANK PRODUCT LABEL INCHES
1 UNLEADED 87 0.00
2 SUPREME 91 0.00
3 DIESEL 0.00
4 0.00
I61200
NOV 15, 2018 9:09 AM
TANK MANIFOLDED PARTNERS
TANK PRODUCT LABEL SIPHON MANIFOLDED TANKS LINE MANIFOLDED TANKS
1 UNLEADED 87 NONE NONE
2 SUPREME 91 NONE NONE
3 DIESEL NONE NONE
4 NONE NONE
I63600
NOV 15, 2018 9:09 AM
PERIODIC LEAK TEST MIN VOLUME
TANK PRODUCT LABEL GALLONS
1 UNLEADED 87 120
2 SUPREME 91 120
3 DIESEL 120
4 0
I62A00
NOV 15, 2018 9:09 AM
ANNUAL LEAK TEST MIN VOLUME
TANK PRODUCT LABEL GALLONS
1 UNLEADED 87 120
2 SUPREME 91 120
3 DIESEL 120
4 0
I62C00
NOV 15, 2018 9:09 AM
TANK PERIODIC TEST TYPE
TANK PRODUCT LABEL PERIODIC TEST TYPE
1 UNLEADED 87 STANDARD
2 SUPREME 91 STANDARD
3 DIESEL STANDARD
4 STANDARD
I62D00
NOV 15, 2018 9:09 AM
TANK LEAK TEST FAIL ALARMS
TANK PRODUCT LABEL
1 UNLEADED 87 GROSS TEST FAIL ALARM DISABLED
PERIODIC TEST FAIL ALARM DISABLED
ANNUAL TEST FAIL ALARM DISABLED
2 SUPREME 91 GROSS TEST FAIL ALARM DISABLED
PERIODIC TEST FAIL ALARM DISABLED
ANNUAL TEST FAIL ALARM DISABLED
3 DIESEL GROSS TEST FAIL ALARM DISABLED
PERIODIC TEST FAIL ALARM DISABLED
ANNUAL TEST FAIL ALARM DISABLED
4 GROSS TEST FAIL ALARM DISABLED
PERIODIC TEST FAIL ALARM DISABLED
ANNUAL TEST FAIL ALARM DISABLED
I63100
NOV 15, 2018 9:09 AM
TANK LEAK TEST AVERAGING
TANK PRODUCT LABEL ANNUAL PERIODIC
1 UNLEADED 87 OFF OFF
2 SUPREME 91 OFF OFF
3 DIESEL OFF OFF
4 OFF OFF
I63000
NOV 15, 2018 9:09 AM
IN-TANK LEAK TEST NOTIFY
TANK PRODUCT LABEL TANK TEST NOTIFY:
1 UNLEADED 87 OFF
2 SUPREME 91 OFF
3 DIESEL OFF
4 OFF
I63200
NOV 15, 2018 9:09 AM
TANK TEST SIPHON BREAK
TANK PRODUCT LABEL SIPHON BREAK
1 UNLEADED 87 OFF
2 SUPREME 91 OFF
3 DIESEL OFF
4 OFF
I61000
NOV 15, 2018 9:09 AM
TANK DELIVERY DELAY
TANK PRODUCT LABEL
1 UNLEADED 87 1
2 SUPREME 91 1
3 DIESEL 1
4 1
I63A00
NOV 15, 2018 9:09 AM
LOW LEVEL PUMP THRESHOLD FOR SEQUENTIAL LINE MANIFOLD
TANK PRODUCT LABEL PUMP THRESHOLD
1 UNLEADED 87 10.00%
2 SUPREME 91 10.00%
3 DIESEL 10.00%
4 10.00%
I61100
NOV 15, 2018 9:09 AM
LEAK TEST METHOD
- - - - - - - - - - - -
TEST ON DATE : ALL TANK
JUL 23, 2010
START TIME : DISABLED
TEST RATE :0.20 GAL/HR
DURATION : 2 HOURS
TST EARLY STOP:DISABLED
I61300
NOV 15, 2018 9:09 AM
CSLD PROBABLITY OF DETECTION
I61400
NOV 15, 2018 9:09 AM
CSLD CLIMATE FACTOR
I61600
NOV 15, 2018 9:09 AM
TANK PRODUCT LABEL CAL UPDATE
1 UNLEADED 87 IMMEDIATE
2 SUPREME 91 IMMEDIATE
3 DIESEL IMMEDIATE
4 IMMEDIATE
I61A00
NOV 15, 2018 9:09 AM
IN-TANK LEAK TEST EARLY STOP
TANK PRODUCT LABEL TST EARLY STOP:
1 UNLEADED 87 DISABLED
2 SUPREME 91 DISABLED
3 DIESEL DISABLED
4 DISABLED
I61B00
NOV 15, 2018 9:09 AM
IN-TANK LEAK GROSS TEST AUTO-CONFIRM
I61C00
NOV 15, 2018 9:09 AM
CSLD REPORT ONLY
I62B00
NOV 15, 2018 9:09 AM
TANK LAST ANNUAL TEST
TANK PRODUCT LABEL DATE
1 UNLEADED 87 ??? 0, 0
2 SUPREME 91 ??? 0, 0
3 DIESEL ??? 0, 0
4 ??? 0, 0
I63300
NOV 15, 2018 9:09 AM
LEAK TEST REPORT FORMAT: NORMAL
I63400
NOV 15, 2018 9:09 AM
RECONCILIATION WARNING LIMIT
TANK PRODUCT LABEL GALLONS
1 UNLEADED 87 0
2 SUPREME 91 0
3 DIESEL 0
4 0
I63500
NOV 15, 2018 9:09 AM
RECONCILIATION ALARM LIMIT
TANK PRODUCT LABEL GALLONS
1 UNLEADED 87 1
2 SUPREME 91 1
3 DIESEL 1
4 1
I63900
NOV 15, 2018 9:09 AM
ACCU CHART END SHAPE FACTOR
TANK PRODUCT LABEL
1 UNLEADED 87
END FACTOR: NONE
2 SUPREME 91
END FACTOR: NONE
3 DIESEL
END FACTOR: NONE
4
END FACTOR: NONE
I78000
NOV 15, 2018 9:09 AM
I77700
NOV 15, 2018 9:09 AM
I77800
NOV 15, 2018 9:09 AM
I78C00
NOV 15, 2018 9:09 AM
I78300
NOV 15, 2018 9:09 AM
I78F00
NOV 15, 2018 9:09 AM
I78700
NOV 15, 2018 9:09 AM
I70200
NOV 15, 2018 9:09 AM
LIQUID LABEL
DEVICE LABEL
1 DISP. 1-2
2 DISP. 3-4
3 DISP. 11-12
4 DISP. 7-8
5 DISP. 9-10
6 DISP 5-6
7 DISP. 13-14
8 DISP. 15-16
9 UNLEADED SUMP
10 SUPREME SUMP
11 DIESEL SUMP
12 UNLEADED ANNULAR
13 SUPREME ANNULAR
14 DIESEL ANNULAR
15 UNLEADED ANN
16
17 UNL ANNULAR
18
19 UNL ANNULAR
20
21
22
23
24 BUBBA SENSOR
I70300
NOV 15, 2018 9:09 AM
LIQUID TYPE
SENSOR LOCATION TYPE
1 DISP. 1-2 TRI-STATE (SINGLE FLOAT)
2 DISP. 3-4 TRI-STATE (SINGLE FLOAT)
3 DISP. 11-12 TRI-STATE (SINGLE FLOAT)
4 DISP. 7-8 TRI-STATE (SINGLE FLOAT)
5 DISP. 9-10 TRI-STATE (SINGLE FLOAT)
6 DISP 5-6 TRI-STATE (SINGLE FLOAT)
7 DISP. 13-14 TRI-STATE (SINGLE FLOAT)
8 DISP. 15-16 TRI-STATE (SINGLE FLOAT)
9 UNLEADED SUMP TRI-STATE (SINGLE FLOAT)
10 SUPREME SUMP TRI-STATE (SINGLE FLOAT)
11 DIESEL SUMP TRI-STATE (SINGLE FLOAT)
12 UNLEADED ANNULAR NORMALLY CLOSED
13 SUPREME ANNULAR NORMALLY CLOSED
14 DIESEL ANNULAR NORMALLY CLOSED
15 UNLEADED ANN NORMALLY CLOSED
16 TRI-STATE (SINGLE FLOAT)
17 UNL ANNULAR NORMALLY CLOSED
18 TRI-STATE (SINGLE FLOAT)
19 UNL ANNULAR NORMALLY CLOSED
20 TRI-STATE (SINGLE FLOAT)
21 TRI-STATE (SINGLE FLOAT)
22 TRI-STATE (SINGLE FLOAT)
23 TRI-STATE (SINGLE FLOAT)
24 BUBBA SENSOR NORMALLY CLOSED
I70400
NOV 15, 2018 9:09 AM
LIQUID CATEGORY
SENSOR LOCATION CATEGORY
1 DISP. 1-2 DISPENSER PAN
2 DISP. 3-4 DISPENSER PAN
3 DISP. 11-12 DISPENSER PAN
4 DISP. 7-8 DISPENSER PAN
5 DISP. 9-10 DISPENSER PAN
6 DISP 5-6 DISPENSER PAN
7 DISP. 13-14 DISPENSER PAN
8 DISP. 15-16 DISPENSER PAN
9 UNLEADED SUMP STP SUMP
10 SUPREME SUMP STP SUMP
11 DIESEL SUMP STP SUMP
12 UNLEADED ANNULAR ANNULAR SPACE
13 SUPREME ANNULAR ANNULAR SPACE
14 DIESEL ANNULAR ANNULAR SPACE
15 UNLEADED ANN ANNULAR SPACE
16 OTHER SENSORS
17 UNL ANNULAR ANNULAR SPACE
18 OTHER SENSORS
19 UNL ANNULAR ANNULAR SPACE
20 OTHER SENSORS
21 OTHER SENSORS
22 OTHER SENSORS
23 OTHER SENSORS
24 BUBBA SENSOR OTHER SENSORS
I74200
NOV 15, 2018 9:09 AM
I74300
NOV 15, 2018 9:09 AM
I74400
NOV 15, 2018 9:09 AM
I74700
NOV 15, 2018 9:09 AM
I74800
NOV 15, 2018 9:09 AM
I74900
NOV 15, 2018 9:09 AM
I7BC00
NOV 15, 2018 9:09 AM
I80200
NOV 15, 2018 9:09 AM
I80300
NOV 15, 2018 9:09 AM
I80400
NOV 15, 2018 9:09 AM
I80700
NOV 15, 2018 9:09 AM
RELAY LABEL
DEVICE LABEL
1 UNLEADED 87
2 SUPREME
3 DIESEL
4 OVERFILL ALARM
5 REMOTE ALARMS
6 REMOTE ALARM
7
8
I80900
NOV 15, 2018 9:09 AM
RELAY ORIENTATION
RELAY DESIGNATION ORIENTATION
1 UNLEADED 87 NORMALLY CLOSED
2 SUPREME NORMALLY CLOSED
3 DIESEL NORMALLY CLOSED
4 OVERFILL ALARM NORMALLY OPEN
5 REMOTE ALARMS NORMALLY CLOSED
6 REMOTE ALARM NORMALLY CLOSED
7 NORMALLY OPEN
8 NORMALLY OPEN
I80B00
NOV 15, 2018 9:09 AM
RELAY TANK ASSIGNMENT
RELAY DESIGNATION TANK
1 UNLEADED 87 1
2 SUPREME 2
3 DIESEL 3
4 OVERFILL ALARM NONE
5 REMOTE ALARMS NONE
6 REMOTE ALARM NONE
7 NONE
8 NONE
I80A00
NOV 15, 2018 9:09 AM
RELAY TYPE
RELAY DESIGNATION TYPE
1 UNLEADED 87 STANDARD
2 SUPREME STANDARD
3 DIESEL STANDARD
4 OVERFILL ALARM STANDARD
5 REMOTE ALARMS STANDARD
6 REMOTE ALARM STANDARD
7 STANDARD
8 STANDARD
I80C00
NOV 15, 2018 9:10 AM
I80800
NOV 15, 2018 9:10 AM
RELAY SETUP REPORT
R 1:UNLEADED 87
TYPE:
STANDARD
NORMALLY CLOSED
TANK #: 1
IN-TANK ALARMS
T 1:LEAK ALARM
LIQUID SENSOR ALMS
L 1:FUEL ALARM
L 2:FUEL ALARM
L 3:FUEL ALARM
L 4:FUEL ALARM
L 5:FUEL ALARM
L 6:FUEL ALARM
L 7:FUEL ALARM
L 8:FUEL ALARM
L 9:FUEL ALARM
L 1:SENSOR OUT ALARM
L 2:SENSOR OUT ALARM
L 3:SENSOR OUT ALARM
L 4:SENSOR OUT ALARM
L 5:SENSOR OUT ALARM
L 6:SENSOR OUT ALARM
L 7:SENSOR OUT ALARM
L 8:SENSOR OUT ALARM
L 9:SENSOR OUT ALARM
L 1:SHORT ALARM
L 2:SHORT ALARM
L 3:SHORT ALARM
L 4:SHORT ALARM
L 5:SHORT ALARM
L 6:SHORT ALARM
L 7:SHORT ALARM
L 8:SHORT ALARM
L 9:SHORT ALARM
ISD SITE ALARMS
ISD GROSS PRES FAIL
ISD DEGRD PRES FAIL
ISD VAPOR LEAK FAIL
ISD VP PRES FAIL
ISD VP STATUS FAIL
ISD HOSE ALARMS
ALL:GROSS COLLECT FAIL
ALL:DEGRD COLLECT FAIL
ALL:FLOW COLLECT FAIL
R 2:SUPREME
TYPE:
STANDARD
NORMALLY CLOSED
TANK #: 2
IN-TANK ALARMS
T 2:LEAK ALARM
T 2:LOW PRODUCT ALARM
LIQUID SENSOR ALMS
L 1:FUEL ALARM
L 2:FUEL ALARM
L 3:FUEL ALARM
L 4:FUEL ALARM
L 5:FUEL ALARM
L 6:FUEL ALARM
L 7:FUEL ALARM
L 8:FUEL ALARM
L10:FUEL ALARM
L 1:SENSOR OUT ALARM
L 2:SENSOR OUT ALARM
L 3:SENSOR OUT ALARM
L 4:SENSOR OUT ALARM
L 5:SENSOR OUT ALARM
L 6:SENSOR OUT ALARM
L 7:SENSOR OUT ALARM
L 8:SENSOR OUT ALARM
L10:SENSOR OUT ALARM
L 1:SHORT ALARM
L 2:SHORT ALARM
L 3:SHORT ALARM
L 4:SHORT ALARM
L 5:SHORT ALARM
L 6:SHORT ALARM
L 7:SHORT ALARM
L 8:SHORT ALARM
L10:SHORT ALARM
ISD SITE ALARMS
ISD GROSS PRES FAIL
ISD DEGRD PRES FAIL
ISD VAPOR LEAK FAIL
ISD VP PRES FAIL
ISD VP STATUS FAIL
ISD HOSE ALARMS
ALL:GROSS COLLECT FAIL
ALL:DEGRD COLLECT FAIL
ALL:FLOW COLLECT FAIL
R 3:DIESEL
TYPE:
STANDARD
NORMALLY CLOSED
TANK #: 3
IN-TANK ALARMS
T 3:LEAK ALARM
T 3:LOW PRODUCT ALARM
LIQUID SENSOR ALMS
L 1:FUEL ALARM
L 4:FUEL ALARM
L 5:FUEL ALARM
L 8:FUEL ALARM
L11:FUEL ALARM
L 1:SENSOR OUT ALARM
L 4:SENSOR OUT ALARM
L 5:SENSOR OUT ALARM
L 8:SENSOR OUT ALARM
L11:SENSOR OUT ALARM
L 1:SHORT ALARM
L 4:SHORT ALARM
L 5:SHORT ALARM
L 8:SHORT ALARM
L11:SHORT ALARM
R 4:OVERFILL ALARM
TYPE:
STANDARD
NORMALLY OPEN
TANK #: NONE
IN-TANK ALARMS
ALL:OVERFILL ALARM
ALL:HIGH PRODUCT ALARM
ALL:MAX PRODUCT ALARM
R 5:REMOTE ALARMS
TYPE:
STANDARD
NORMALLY CLOSED
TANK #: NONE
IN-TANK ALARMS
ALL:LEAK ALARM
ALL:HIGH WATER ALARM
ALL:OVERFILL ALARM
ALL:LOW PRODUCT ALARM
ALL:SUDDEN LOSS ALARM
ALL:HIGH PRODUCT ALARM
ALL:INVALID FUEL LEVEL
ALL:PROBE OUT
ALL:HIGH WATER WARNING
ALL:DELIVERY NEEDED
ALL:MAX PRODUCT ALARM
ALL:GROSS TEST FAIL
ALL:PERIODIC TEST FAIL
ALL:ANNUAL TEST FAIL
ALL:PER TST NEEDED WRN
LIQUID SENSOR ALMS
L 1:FUEL ALARM
L 2:FUEL ALARM
L 3:FUEL ALARM
L 4:FUEL ALARM
L 5:FUEL ALARM
L 6:FUEL ALARM
L 7:FUEL ALARM
L 8:FUEL ALARM
L 9:FUEL ALARM
L10:FUEL ALARM
L11:FUEL ALARM
L12:FUEL ALARM
L13:FUEL ALARM
L14:FUEL ALARM
L15:FUEL ALARM
L16:FUEL ALARM
L 1:SENSOR OUT ALARM
L 2:SENSOR OUT ALARM
L 3:SENSOR OUT ALARM
L 4:SENSOR OUT ALARM
L 5:SENSOR OUT ALARM
L 6:SENSOR OUT ALARM
L 7:SENSOR OUT ALARM
L 8:SENSOR OUT ALARM
L 9:SENSOR OUT ALARM
L10:SENSOR OUT ALARM
L11:SENSOR OUT ALARM
L12:SENSOR OUT ALARM
L13:SENSOR OUT ALARM
L14:SENSOR OUT ALARM
L15:SENSOR OUT ALARM
L16:SENSOR OUT ALARM
L 1:SHORT ALARM
L 2:SHORT ALARM
L 3:SHORT ALARM
L 4:SHORT ALARM
L 5:SHORT ALARM
L 6:SHORT ALARM
L 7:SHORT ALARM
L 8:SHORT ALARM
L 9:SHORT ALARM
L10:SHORT ALARM
L11:SHORT ALARM
L12:SHORT ALARM
L13:SHORT ALARM
L14:SHORT ALARM
L15:SHORT ALARM
L16:SHORT ALARM
SMARTSENSOR ALARMS
ALL:SETUP DATA WARNING
ALL:COMMUNICATION ALARM
ALL:SENSOR FAULT ALARM
ALL:SENSOR FAULT WARN
ISD SITE ALARMS
ISD STAGE I WARN
ISD GROSS PRES WARN
ISD GROSS PRES FAIL
ISD DEGRD PRES WARN
ISD DEGRD PRES FAIL
ISD VAPOR LEAK WARN
ISD VAPOR LEAK FAIL
ISD VP PRES WARN
ISD VP PRES FAIL
ISD VP STATUS WARN
ISD VP STATUS FAIL
MISSING RELAY SETUP
MISSING HOSE SETUP
MISSING TANK SETUP
MISS VAPOR FLOW MTR
MISS VAPOR PRES SEN
MISSING VP INPUT
ISD SETUP WARN
ISD SETUP FAIL
ISD SENSOR OUT WARN
ISD SENSOR OUT FAIL
ISD HOSE ALARMS
ALL:GROSS COLLECT WARN
ALL:GROSS COLLECT FAIL
ALL:DEGRD COLLECT WARN
ALL:DEGRD COLLECT FAIL
ALL:FLOW COLLECT WARN
ALL:FLOW COLLECT FAIL
ALL:AIRFLOW MTR SETUP
VAPOR FLW MTR ALMS
ALL:CHK VAPOR FLOW MTR
R 6:REMOTE ALARM
TYPE:
STANDARD
NORMALLY CLOSED
TANK #: NONE
IN-TANK ALARMS
ALL:OVERFILL ALARM
ALL:HIGH PRODUCT ALARM
ALL:MAX PRODUCT ALARM
LIQUID SENSOR ALMS
L 1:FUEL ALARM
L 2:FUEL ALARM
L 3:FUEL ALARM
L 4:FUEL ALARM
L 5:FUEL ALARM
L 6:FUEL ALARM
L 7:FUEL ALARM
L 8:FUEL ALARM
L 9:FUEL ALARM
L10:FUEL ALARM
L11:FUEL ALARM
L12:FUEL ALARM
L13:FUEL ALARM
L14:FUEL ALARM
L15:FUEL ALARM
L16:FUEL ALARM
L 1:SENSOR OUT ALARM
L 2:SENSOR OUT ALARM
L 3:SENSOR OUT ALARM
L 4:SENSOR OUT ALARM
L 5:SENSOR OUT ALARM
L 6:SENSOR OUT ALARM
L 7:SENSOR OUT ALARM
L 8:SENSOR OUT ALARM
L 9:SENSOR OUT ALARM
L10:SENSOR OUT ALARM
L11:SENSOR OUT ALARM
L12:SENSOR OUT ALARM
L13:SENSOR OUT ALARM
L14:SENSOR OUT ALARM
L15:SENSOR OUT ALARM
L16:SENSOR OUT ALARM
L 1:SHORT ALARM
L 2:SHORT ALARM
L 3:SHORT ALARM
L 4:SHORT ALARM
L 5:SHORT ALARM
L 6:SHORT ALARM
L 7:SHORT ALARM
L 8:SHORT ALARM
L 9:SHORT ALARM
L10:SHORT ALARM
L11:SHORT ALARM
L12:SHORT ALARM
L13:SHORT ALARM
L14:SHORT ALARM
L15:SHORT ALARM
L16:SHORT ALARM
SMARTSENSOR ALARMS
ALL:COMMUNICATION ALARM
ISD SITE ALARMS
ISD STAGE I WARN
ISD GROSS PRES WARN
ISD GROSS PRES FAIL
ISD DEGRD PRES WARN
ISD DEGRD PRES FAIL
ISD VAPOR LEAK WARN
ISD VAPOR LEAK FAIL
ISD VP PRES WARN
ISD VP PRES FAIL
ISD VP STATUS WARN
ISD VP STATUS FAIL
MISSING RELAY SETUP
MISSING HOSE SETUP
ISD SENSOR OUT WARN
ISD SENSOR OUT FAIL
ISD HOSE ALARMS
ALL:GROSS COLLECT WARN
ALL:GROSS COLLECT FAIL
ALL:DEGRD COLLECT WARN
ALL:DEGRD COLLECT FAIL
ALL:FLOW COLLECT WARN
ALL:FLOW COLLECT FAIL
ALL:AIRFLOW MTR SETUP
VAPOR FLW MTR ALMS
ALL:CHK VAPOR FLOW MTR
R 7:
TYPE:
STANDARD
NORMALLY OPEN
TANK #: NONE
- NO ALARM ASSIGNMENTS -
R 8:
TYPE:
STANDARD
NORMALLY OPEN
TANK #: NONE
- NO ALARM ASSIGNMENTS -
I79000
NOV 15, 2018 9:10 AM
EDIM:1 VR:349643-001-B TD:97.10.27.11.25
I79100
NOV 15, 2018 9:10 AM
I72300
NOV 15, 2018 9:10 AM
286917 SPARKLING IMA
2301 H ST.
BAKERSFIELD,CA 93301
661-324-8455
SMARTSENSOR ASSIGNMENT
DEVICE LABEL CATEGORY
01 FM 1-2 AIR FLOW METER
02 FM 3-4 AIR FLOW METER
03 FM 5-6 AIR FLOW METER
04 FM 7-8 AIR FLOW METER
05 FM 9-10 AIR FLOW METER
06 FM 11-12 AIR FLOW METER
07 FM 13-14 AIR FLOW METER
08 PRESSURE SENSOR VAPOR PRESSURE
09 FM 15-16 AIR FLOW METER
10 UNKNOWN
11 UNKNOWN
12 UNKNOWN
13 UNKNOWN
14 UNKNOWN
15 UNKNOWN
16 UNKNOWN
17 UNKNOWN
18 UNKNOWN
19 UNKNOWN
20 UNKNOWN
21 UNKNOWN
22 UNKNOWN
23 UNKNOWN
24 UNKNOWN
25 UNKNOWN
26 UNKNOWN
27 UNKNOWN
28 UNKNOWN
29 UNKNOWN
30 UNKNOWN
31 UNKNOWN
32 UNKNOWN
33 UNKNOWN
34 UNKNOWN
35 UNKNOWN
36 UNKNOWN
37 UNKNOWN
38 UNKNOWN
39 UNKNOWN
40 UNKNOWN
IV4E00
NOV 15, 2018 9:10 AM
286917 SPARKLING IMA
2301 H ST.
BAKERSFIELD,CA 93301
661-324-8455
EVR/ISD SETUP
TYPE: VACUUM ASSIST
VACUUM ASSIST TYPE: HEALY VAC
IV4F00
NOV 15, 2018 9:10 AM
286917 SPARKLING IMA
2301 H ST.
BAKERSFIELD,CA 93301
661-324-8455
NOZZLE A/L RANGE
A/L RATIO: 0.95 - 1.15
IV4000
NOV 15, 2018 9:10 AM
286917 SPARKLING IMA
2301 H ST.
BAKERSFIELD,CA 93301
661-324-8455
VAPOR PROCESSOR TYPE
NONE
IV4700
NOV 15, 2018 9:10 AM
286917 SPARKLING IMA
2301 H ST.
BAKERSFIELD,CA 93301
661-324-8455
ASSESSMENT TIME
START TIME: 10:00 AM
TIME DELAY MINUTES: 1
IV5200
NOV 15, 2018 9:10 AM
286917 SPARKLING IMA
2301 H ST.
BAKERSFIELD,CA 93301
661-324-8455
ACCEPT HIGH ORVR: NO
IV4A00
NOV 15, 2018 9:10 AM
286917 SPARKLING IMA
2301 H ST.
BAKERSFIELD,CA 93301
661-324-8455
ISD HOSE TABLE
HOSE FP FP AFM HOSE
ID ID LABEL ID LABEL
01 01 01 01 BLEND3
02 02 02 01 BLEND3
03 03 03 02 BLEND3
04 04 04 02 BLEND3
05 05 05 03 BLEND3
06 06 06 03 BLEND3
07 07 07 04 BLEND3
08 08 08 04 BLEND3
09 09 09 05 BLEND3
10 16 10 05 BLEND3
11 17 11 06 BLEND3
12 18 12 06 BLEND3
13 19 13 07 BLEND3
14 20 14 07 BLEND3
15 21 15 08 BLEND3
16 22 16 08 BLEND3
IV4B00
NOV 15, 2018 9:10 AM
286917 SPARKLING IMA
2301 H ST.
BAKERSFIELD,CA 93301
661-324-8455
PRODUCT/HOSE MAP TABLE
FP AFID M1/H1 M2/H2 M3/H3 M4/H4
01 01 01/01 02/01 09/01 xx/xx
02 01 01/02 09/02 02/02 xx/xx
03 02 01/03 09/03 02/03 xx/xx
04 02 01/04 09/04 02/04 xx/xx
05 03 01/05 09/05 02/05 xx/xx
06 03 01/06 09/06 02/06 xx/xx
07 04 01/07 09/07 02/07 xx/xx
08 04 01/08 09/08 02/08 xx/xx
09 05 01/09 09/09 02/09 xx/xx
16 05 01/10 09/10 02/10 xx/xx
17 06 01/11 09/11 02/11 xx/xx
18 06 01/12 09/12 02/12 xx/xx
19 07 01/13 09/13 02/13 xx/xx
20 07 01/14 09/14 02/14 xx/xx
21 08 01/15 09/15 02/15 xx/xx
22 08 01/16 09/16 02/16 xx/xx
IV4900
NOV 15, 2018 9:10 AM
286917 SPARKLING IMA
2301 H ST.
BAKERSFIELD,CA 93301
661-324-8455
LABEL TABLE
ID LABEL
01 UNASSIGNED
02 BLEND3
03 REGULAR
04 MID GRADE
05 PREMIUM
06 GOLD
07 BRONZE
08 SILVER
09 BLEND2
10 BLEND4
IV1000
NOV 15, 2018 9:10 AM
ISD VERSION: 01.03
Sparkling chevron alarm before
Responses Received:
I10200
NOV 15, 2018 9:12 AM
286917 SPARKLING IMA
2301 H ST.
BAKERSFIELD,CA 93301
661-324-8455
SYSTEM CONFIGURATION
SLOT BOARD TYPE POWER ON RESET CURRENT
1 UNUSED 10020167 9640201
2 4 PROBE / G.T. 163726 163566
3 8SMARTSENSOR BD 39558 39532
4 7SMARTSENSOR BD 508286 507689
5 INTERSTITIAL BD 201774 201579
6 INTERSTITIAL BD 202243 202022
7 INTERSTITIAL BD 10002575 200716
8 UNUSED 9996797 9634813
9 RELAY BOARD 14986 15007
10 RELAY BOARD 14964 14962
11 UNUSED 10007979 9644130
12 UNUSED 9986521 9625482
13 UNUSED 9995371 9622463
14 UNUSED 9993588 9634336
15 UNUSED 9983600 9623134
16 UNUSED 10000096 9628076
COMM 1 ELEC DISP INT. 100682 100635
COMM 2 RS232 SERIAL BD 14964 15007
COMM 3 SERIAL SAT BD 9994383 480337
COMM 4 UNUSED 9993287 9630781
COMM 5 UNUSED 9990602 9628657
COMM 6 UNUSED 9984760 9624923
I90200
NOV 15, 2018 9:12 AM
SOFTWARE REVISION LEVEL
VERSION 330.01
SOFTWARE# 346330-100-B
CREATED - 10.07.23.17.25
S-MODULE# 330160-004-a
SYSTEM FEATURES:
PERIODIC IN-TANK TESTS
ANNUAL IN-TANK TESTS
CSLD
BIR
FUEL MANAGER
ISD
PLLD
0.10 AUTO
0.20 REPETITIV
WPLLD
0.10 AUTO
0.20 REPETITIV
I11100
NOV 15, 2018 9:12 AM
286917 SPARKLING IMA
2301 H ST.
BAKERSFIELD,CA 93301
661-324-8455
PRIORITY ALARM HISTORY
ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME
T 1 TANK UNLEADED 87 OVERFILL ALARM CLEAR 11-13-18 1:00AM
T 1 TANK UNLEADED 87 OVERFILL ALARM ALARM 11-13-18 12:56AM
E 1 OTHER COMMUNICATION ALARM CLEAR 11-12-18 2:04AM
E 1 OTHER COMMUNICATION ALARM ALARM 11-12-18 2:02AM
T 1 TANK UNLEADED 87 OVERFILL ALARM CLEAR 11-06-18 11:27PM
T 1 TANK UNLEADED 87 OVERFILL ALARM ALARM 11-06-18 11:25PM
E 1 OTHER COMMUNICATION ALARM CLEAR 11-05-18 2:03AM
E 1 OTHER COMMUNICATION ALARM ALARM 11-05-18 2:01AM
E 1 OTHER COMMUNICATION ALARM CLEAR 10-29-18 2:02AM
E 1 OTHER COMMUNICATION ALARM ALARM 10-29-18 2:00AM
D 8 OTHER VEEDER ROOT (FMS) AUTODIAL FAILURE CLEAR 10-24-18 7:44AM
D 8 OTHER VEEDER ROOT (FMS) AUTODIAL FAILURE ALARM 10-24-18 2:31AM
E 1 OTHER COMMUNICATION ALARM CLEAR 10-22-18 2:05AM
E 1 OTHER COMMUNICATION ALARM ALARM 10-22-18 2:02AM
E 1 OTHER COMMUNICATION ALARM CLEAR 10-15-18 2:06AM
E 1 OTHER COMMUNICATION ALARM ALARM 10-15-18 2:03AM
T 1 TANK UNLEADED 87 OVERFILL ALARM CLEAR 10-14-18 10:32AM
T 1 TANK UNLEADED 87 OVERFILL ALARM ALARM 10-14-18 10:29AM
E 1 OTHER COMMUNICATION ALARM CLEAR 10-08-18 2:07AM
E 1 OTHER COMMUNICATION ALARM ALARM 10-08-18 2:04AM
E 1 OTHER COMMUNICATION ALARM CLEAR 10-01-18 10:09PM
E 1 OTHER COMMUNICATION ALARM ALARM 10-01-18 10:06PM
E 1 OTHER COMMUNICATION ALARM CLEAR 10-01-18 2:10AM
E 1 OTHER COMMUNICATION ALARM ALARM 10-01-18 2:08AM
E 1 OTHER COMMUNICATION ALARM CLEAR 9-24-18 2:05AM
E 1 OTHER COMMUNICATION ALARM ALARM 9-24-18 2:03AM
T 1 TANK UNLEADED 87 OVERFILL ALARM CLEAR 9-22-18 7:40AM
T 1 TANK UNLEADED 87 OVERFILL ALARM ALARM 9-22-18 7:37AM
L12 ANNULAR UNLEADED ANNULAR FUEL ALARM CLEAR 9-18-18 10:25AM
E 1 OTHER COMMUNICATION ALARM CLEAR 9-17-18 2:10AM
E 1 OTHER COMMUNICATION ALARM ALARM 9-17-18 2:08AM
L12 ANNULAR UNLEADED ANNULAR FUEL ALARM ALARM 9-12-18 6:16PM
L12 ANNULAR UNLEADED ANNULAR FUEL ALARM CLEAR 9-12-18 12:39PM
L12 ANNULAR UNLEADED ANNULAR FUEL ALARM ALARM 9-12-18 12:24PM
E 1 OTHER COMMUNICATION ALARM CLEAR 9-10-18 2:07AM
E 1 OTHER COMMUNICATION ALARM ALARM 9-10-18 2:05AM
L12 ANNULAR UNLEADED ANNULAR FUEL ALARM CLEAR 9-04-18 9:12AM
E 1 OTHER COMMUNICATION ALARM CLEAR 9-03-18 2:13AM
E 1 OTHER COMMUNICATION ALARM ALARM 9-03-18 2:11AM
L12 ANNULAR UNLEADED ANNULAR FUEL ALARM ALARM 9-02-18 3:34AM
E 1 OTHER COMMUNICATION ALARM CLEAR 8-27-18 2:07AM
E 1 OTHER COMMUNICATION ALARM ALARM 8-27-18 2:05AM
E 1 OTHER COMMUNICATION ALARM CLEAR 8-20-18 2:07AM
E 1 OTHER COMMUNICATION ALARM ALARM 8-20-18 2:05AM
E 1 OTHER COMMUNICATION ALARM CLEAR 8-13-18 2:07AM
E 1 OTHER COMMUNICATION ALARM ALARM 8-13-18 2:05AM
L12 ANNULAR UNLEADED ANNULAR FUEL ALARM CLEAR 8-06-18 12:17PM
E 1 OTHER COMMUNICATION ALARM CLEAR 8-06-18 2:08AM
E 1 OTHER COMMUNICATION ALARM ALARM 8-06-18 2:05AM
L12 ANNULAR UNLEADED ANNULAR FUEL ALARM ALARM 8-04-18 7:59AM
I11200
NOV 15, 2018 9:13 AM
286917 SPARKLING IMA
2301 H ST.
BAKERSFIELD,CA 93301
661-324-8455
NON-PRIORITY ALARM HISTORY
ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME
SYSTEM PRINTER ERROR CLEAR 11-13-18 2:30PM
SYSTEM PAPER OUT CLEAR 11-13-18 2:30PM
SYSTEM PRINTER ERROR ALARM 11-13-18 2:30PM
SYSTEM PAPER OUT ALARM 11-13-18 2:30PM
SYSTEM PRINTER ERROR CLEAR 11-13-18 2:30PM
SYSTEM PAPER OUT CLEAR 11-13-18 2:30PM
SYSTEM PRINTER ERROR ALARM 11-13-18 2:30PM
SYSTEM PAPER OUT ALARM 11-13-18 2:30PM
SYSTEM PRINTER ERROR CLEAR 11-13-18 2:30PM
SYSTEM PAPER OUT CLEAR 11-13-18 2:30PM
SYSTEM PRINTER ERROR ALARM 11-13-18 2:30PM
SYSTEM PAPER OUT ALARM 11-13-18 2:30PM
OTHER ISD GROSS PRES WARN CLEAR 11-11-18 2:35PM
OTHER ISD GROSS PRES WARN ALARM 11-11-18 10:02AM
SYSTEM PRINTER ERROR CLEAR 11-09-18 9:46AM
SYSTEM PRINTER ERROR ALARM 11-09-18 9:46AM
SYSTEM PRINTER ERROR CLEAR 11-08-18 3:43PM
SYSTEM PAPER OUT CLEAR 11-08-18 3:43PM
SYSTEM PRINTER ERROR ALARM 11-08-18 3:42PM
SYSTEM PAPER OUT ALARM 11-08-18 3:42PM
SYSTEM PRINTER ERROR CLEAR 11-07-18 7:26AM
SYSTEM PAPER OUT CLEAR 11-07-18 7:26AM
SYSTEM PRINTER ERROR ALARM 11-07-18 7:25AM
SYSTEM PAPER OUT ALARM 11-07-18 7:25AM
SYSTEM PRINTER ERROR CLEAR 11-07-18 7:25AM
SYSTEM PAPER OUT CLEAR 11-07-18 7:25AM
SYSTEM PRINTER ERROR ALARM 11-07-18 7:24AM
SYSTEM PAPER OUT ALARM 11-07-18 7:24AM
OTHER ISD GROSS PRES WARN CLEAR 11-04-18 10:18AM
OTHER ISD GROSS PRES WARN ALARM 11-04-18 10:03AM
SYSTEM PRINTER ERROR CLEAR 10-22-18 12:29PM
SYSTEM PAPER OUT CLEAR 10-22-18 12:29PM
SYSTEM PAPER OUT ALARM 10-22-18 12:29PM
SYSTEM PRINTER ERROR ALARM 10-22-18 12:29PM
h12 OTHER FP12: BLEND3 DEGRD COLLECT WARN CLEAR 10-16-18 12:15PM
h12 OTHER FP12: BLEND3 DEGRD COLLECT WARN ALARM 10-10-18 10:02AM
SYSTEM PRINTER ERROR CLEAR 10-10-18 4:30AM
SYSTEM PAPER OUT CLEAR 10-10-18 4:30AM
SYSTEM PRINTER ERROR ALARM 10-10-18 4:30AM
SYSTEM PAPER OUT ALARM 10-10-18 4:30AM
h 3 OTHER FP3: BLEND3 DEGRD COLLECT WARN CLEAR 10-05-18 10:00AM
h 3 OTHER FP3: BLEND3 DEGRD COLLECT WARN ALARM 10-04-18 10:02AM
h 1 OTHER FP1: BLEND3 DEGRD COLLECT WARN CLEAR 10-04-18 10:00AM
h 1 OTHER FP1: BLEND3 DEGRD COLLECT WARN ALARM 10-03-18 10:02AM
SYSTEM PRINTER ERROR CLEAR 9-24-18 2:59PM
SYSTEM PAPER OUT CLEAR 9-24-18 2:59PM
SYSTEM PRINTER ERROR ALARM 9-24-18 2:59PM
SYSTEM PAPER OUT ALARM 9-24-18 2:59PM
h11 OTHER FP11: BLEND3 DEGRD COLLECT WARN CLEAR 9-24-18 10:00AM
h11 OTHER FP11: BLEND3 DEGRD COLLECT WARN ALARM 9-23-18 10:01AM
I20600
NOV 15, 2018 9:13 AM
286917 SPARKLING IMA
2301 H ST.
BAKERSFIELD,CA 93301
661-324-8455
TANK ALARM HISTORY
TANK 1 UNLEADED 87
OVERFILL ALARM NOV 13, 2018 12:56 AM
NOV 6, 2018 11:25 PM
OCT 14, 2018 10:29 AM
LOW PRODUCT ALARM NOV 19, 2013 9:27 AM
JUN 26, 2013 4:22 PM
HIGH PRODUCT ALARM DEC 1, 2014 11:11 AM
MAR 7, 2013 5:09 AM
FEB 25, 2013 4:03 AM
INVALID FUEL LEVEL NOV 19, 2015 9:08 AM
NOV 19, 2013 9:27 AM
PROBE OUT NOV 20, 2017 4:16 PM
NOV 20, 2017 4:03 PM
NOV 20, 2017 3:49 PM
DELIVERY NEEDED NOV 20, 2017 3:49 PM
JUL 20, 2017 8:00 PM
AUG 6, 2015 9:47 AM
LOW TEMP WARNING NOV 20, 2017 4:17 PM
NOV 16, 2016 10:22 AM
NOV 16, 2016 9:53 AM
TANK 2 SUPREME 91
OVERFILL ALARM DEC 30, 2017 9:13 AM
NOV 15, 2017 10:22 AM
NOV 16, 2016 10:23 AM
LOW PRODUCT ALARM NOV 16, 2016 9:50 AM
INVALID FUEL LEVEL NOV 19, 2014 9:15 AM
NOV 19, 2014 8:50 AM
NOV 19, 2012 9:00 AM
PROBE OUT NOV 20, 2017 4:17 PM
NOV 20, 2017 4:02 PM
NOV 15, 2017 10:22 AM
DELIVERY NEEDED NOV 20, 2017 4:02 PM
NOV 15, 2017 9:24 AM
NOV 16, 2016 9:50 AM
LOW TEMP WARNING NOV 20, 2017 4:18 PM
NOV 16, 2016 10:25 AM
NOV 16, 2016 9:51 AM
TANK 3 DIESEL
OVERFILL ALARM NOV 15, 2017 10:18 AM
NOV 16, 2016 10:26 AM
NOV 19, 2015 9:48 AM
LOW PRODUCT ALARM NOV 19, 2015 9:05 AM
HIGH PRODUCT ALARM NOV 15, 2017 10:18 AM
INVALID FUEL LEVEL NOV 16, 2016 9:51 AM
PROBE OUT NOV 15, 2017 10:19 AM
NOV 15, 2017 9:26 AM
NOV 16, 2016 10:27 AM
DELIVERY NEEDED NOV 16, 2016 9:50 AM
NOV 19, 2015 9:05 AM
LOW TEMP WARNING NOV 19, 2015 9:50 AM
NOV 19, 2014 9:18 AM
NOV 19, 2013 10:08 AM
I38200
NOV 15, 2018 9:13 AM
I30200
NOV 15, 2018 9:13 AM
286917 SPARKLING IMA
2301 H ST.
BAKERSFIELD,CA 93301
661-324-8455
LIQUID ALARM HISTORY REPORT
SENSOR LOCATION
1 DISP. 1-2
NOV 15, 2017 10:47 AM SENSOR OUT ALARM
NOV 15, 2017 10:30 AM FUEL ALARM
NOV 16, 2016 10:35 AM SENSOR OUT ALARM
2 DISP. 3-4
NOV 15, 2017 10:48 AM SENSOR OUT ALARM
NOV 15, 2017 10:31 AM FUEL ALARM
NOV 16, 2016 10:35 AM SENSOR OUT ALARM
3 DISP. 11-12
NOV 15, 2017 10:48 AM SENSOR OUT ALARM
NOV 15, 2017 10:34 AM FUEL ALARM
NOV 16, 2016 10:35 AM SENSOR OUT ALARM
4 DISP. 7-8
NOV 15, 2017 10:48 AM SENSOR OUT ALARM
NOV 15, 2017 10:33 AM FUEL ALARM
NOV 16, 2016 10:35 AM SENSOR OUT ALARM
5 DISP. 9-10
NOV 15, 2017 10:47 AM SENSOR OUT ALARM
NOV 15, 2017 10:34 AM FUEL ALARM
MAY 24, 2017 9:16 AM FUEL ALARM
6 DISP 5-6
NOV 15, 2017 10:47 AM SENSOR OUT ALARM
NOV 15, 2017 10:32 AM FUEL ALARM
NOV 16, 2016 10:35 AM SENSOR OUT ALARM
7 DISP. 13-14
NOV 15, 2017 10:48 AM SENSOR OUT ALARM
NOV 15, 2017 10:36 AM FUEL ALARM
NOV 16, 2016 10:35 AM SENSOR OUT ALARM
8 DISP. 15-16
NOV 15, 2017 10:48 AM SENSOR OUT ALARM
NOV 15, 2017 10:30 AM FUEL ALARM
NOV 16, 2016 10:35 AM SENSOR OUT ALARM
9 UNLEADED SUMP
NOV 15, 2017 10:47 AM SENSOR OUT ALARM
NOV 15, 2017 10:28 AM FUEL ALARM
NOV 16, 2016 10:35 AM SENSOR OUT ALARM
10 SUPREME SUMP
NOV 15, 2017 10:47 AM SENSOR OUT ALARM
NOV 15, 2017 10:28 AM FUEL ALARM
MAR 28, 2017 2:43 PM SETUP DATA WARNING
11 DIESEL SUMP
NOV 15, 2017 10:47 AM SENSOR OUT ALARM
NOV 15, 2017 10:29 AM FUEL ALARM
NOV 16, 2016 10:35 AM SENSOR OUT ALARM
12 UNLEADED ANNULAR
SEP 12, 2018 6:16 PM FUEL ALARM
SEP 12, 2018 12:24 PM FUEL ALARM
SEP 2, 2018 3:34 AM FUEL ALARM
13 SUPREME ANNULAR
NOV 15, 2017 10:47 AM FUEL ALARM
NOV 15, 2017 10:05 AM FUEL ALARM
MAR 28, 2017 2:38 PM FUEL ALARM
14 DIESEL ANNULAR
NOV 15, 2017 10:47 AM FUEL ALARM
NOV 15, 2017 9:48 AM FUEL ALARM
NOV 16, 2016 10:11 AM FUEL ALARM
I31600
NOV 15, 2018 9:13 AM
286917 SPARKLING IMA
2301 H ST.
BAKERSFIELD,CA 93301
661-324-8455
SMART SENSOR ALARM HISTORY REPORT
SENSOR LOCATION
1 FM 1-2
AUG 23, 2013 3:29 PM COMMUNICATION ALARM
2 FM 3-4
3 FM 5-6
4 FM 7-8
5 FM 9-10
MAY 19, 2014 10:48 PM COMMUNICATION ALARM
6 FM 11-12
7 FM 13-14
8 PRESSURE SENSOR
NOV 16, 2016 10:36 AM COMMUNICATION ALARM
JUL 23, 2010 8:06 AM COMMUNICATION ALARM
9 FM 15-16
I40200
NOV 15, 2018 9:13 AM
I40300
NOV 15, 2018 9:13 AM
I34200
NOV 15, 2018 9:13 AM
I34700
NOV 15, 2018 9:13 AM
IV0100
NOV 15, 2018 9:13 AM
286917 SPARKLING IMA
2301 H ST.
BAKERSFIELD,CA 93301
661-324-8455
ISD ALARM STATUS REPORT
EVR TYPE: VACUUM ASSIST
ISD TYPE: 01.03
VAPOR PROCESSOR TYPE: NONE
OVERALL STATUS :PASS EVR VAPOR COLLECTION :PASS
EVR VAPOR CONTAINMENT :PASS
ISD MONITOR UP-TIME :100%
EVR/ISD PASS TIME :100%
WARNING ALARMS
DATE TIME DESCRIPTION READING VALUE
18-11-11 10:02:35 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.47
18-11-04 10:03:27 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 1.84
18-10-16 10:03:57 A/L RATIO DEGRADATION FP12 BLEND3 0.80
18-10-15 10:04:28 A/L RATIO DEGRADATION FP12 BLEND3 0.79
18-10-14 10:04:21 A/L RATIO DEGRADATION FP12 BLEND3 0.79
18-10-13 10:03:01 A/L RATIO DEGRADATION FP12 BLEND3 0.80
18-10-12 10:02:29 A/L RATIO DEGRADATION FP12 BLEND3 0.78
18-10-11 10:02:09 A/L RATIO DEGRADATION FP12 BLEND3 0.77
18-10-10 10:02:40 A/L RATIO DEGRADATION FP12 BLEND3 0.76
18-10-04 10:02:40 A/L RATIO DEGRADATION FP 3 BLEND3 0.80
FAILURE ALARMS
DATE TIME DESCRIPTION READING VALUE
16-10-13 10:03:26 A/L RATIO GROSS BLOCKAGE FP 7 BLEND3 BLKD
15-04-02 10:01:23 A/L RATIO GROSS BLOCKAGE FP12 BLEND3 BLKD
11-08-16 10:03:25 A/L RATIO GROSS BLOCKAGE FP 6 BLEND3 BLKD
10-10-08 10:01:09 SETUP SELFTEST
MISSING HOSE(S)
10-10-07 10:01:09 SETUP SELFTEST
MISSING HOSE(S)
10-10-06 10:01:09 SETUP SELFTEST
MISSING HOSE(S)
10-10-05 10:01:09 SETUP SELFTEST
MISSING HOSE(S)
10-10-04 10:01:10 SETUP SELFTEST
MISSING HOSE(S)
10-10-03 10:01:09 SETUP SELFTEST
MISSING HOSE(S)
10-10-02 10:01:09 SETUP SELFTEST
MISSING HOSE(S)
SHUTDOWN & MISCELLANEOUS EVENTS
DATE TIME DESCRIPTION ACTION/NAME
18-11-14 10:02:24 READINESS ISD:PP EVR:NP EVR READINESS PENDING
18-11-13 10:02:43 READINESS ISD:PP EVR:NP EVR READINESS PENDING
18-11-12 10:02:54 READINESS ISD:PP EVR:NP EVR READINESS PENDING
18-11-11 14:35:13 CONTAINMENT GROSS & DEGRD TEST MANUALLY CLEARED
18-11-11 10:02:35 READINESS ISD:PP EVR:NF CHECK EVR SYSTEM
18-11-10 10:03:26 READINESS ISD:PP EVR:NP EVR READINESS PENDING
18-11-09 10:03:13 READINESS ISD:PP EVR:NP EVR READINESS PENDING
18-11-08 10:02:59 READINESS ISD:PP EVR:NP EVR READINESS PENDING
18-11-07 10:04:23 READINESS ISD:PP EVR:NP EVR READINESS PENDING
18-11-06 10:03:44 READINESS ISD:PP EVR:NP EVR READINESS PENDING
Sparkling chevron after history
Responses Received:
I10200
NOV 15, 2018 11:21 AM
286917 SPARKLING IMA
2301 H ST.
BAKERSFIELD,CA 93301
661-324-8455
SYSTEM CONFIGURATION
SLOT BOARD TYPE POWER ON RESET CURRENT
1 UNUSED 10020167 9818532
2 4 PROBE / G.T. 163726 163131
3 8SMARTSENSOR BD 39558 39477
4 7SMARTSENSOR BD 508286 506344
5 INTERSTITIAL BD 201774 201236
6 INTERSTITIAL BD 202243 201555
7 INTERSTITIAL BD 10002575 200416
8 UNUSED 9996797 9807597
9 RELAY BOARD 14986 14985
10 RELAY BOARD 14964 14941
11 UNUSED 10007979 9833421
12 UNUSED 9986521 9795518
13 UNUSED 9995371 9817958
14 UNUSED 9993588 9810959
15 UNUSED 9983600 9809210
16 UNUSED 10000096 9817980
COMM 1 ELEC DISP INT. 100682 100400
COMM 2 RS232 SERIAL BD 14964 14985
COMM 3 SERIAL SAT BD 9994383 479887
COMM 4 UNUSED 9993287 9814524
COMM 5 UNUSED 9990602 9814196
COMM 6 UNUSED 9984760 9794993
I90200
NOV 15, 2018 11:21 AM
SOFTWARE REVISION LEVEL
VERSION 330.01
SOFTWARE# 346330-100-B
CREATED - 10.07.23.17.25
S-MODULE# 330160-004-a
SYSTEM FEATURES:
PERIODIC IN-TANK TESTS
ANNUAL IN-TANK TESTS
CSLD
BIR
FUEL MANAGER
ISD
PLLD
0.10 AUTO
0.20 REPETITIV
WPLLD
0.10 AUTO
0.20 REPETITIV
I11100
NOV 15, 2018 11:21 AM
286917 SPARKLING IMA
2301 H ST.
BAKERSFIELD,CA 93301
661-324-8455
PRIORITY ALARM HISTORY
ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME
L14 ANNULAR DIESEL ANNULAR FUEL ALARM CLEAR 11-15-18 10:27AM
L12 ANNULAR UNLEADED ANNULAR FUEL ALARM CLEAR 11-15-18 10:27AM
L11 STP SUMP DIESEL SUMP SENSOR OUT ALARM CLEAR 11-15-18 10:27AM
L 4 DISP PAN DISP. 7-8 SENSOR OUT ALARM CLEAR 11-15-18 10:27AM
L13 ANNULAR SUPREME ANNULAR FUEL ALARM CLEAR 11-15-18 10:27AM
L10 STP SUMP SUPREME SUMP SENSOR OUT ALARM CLEAR 11-15-18 10:27AM
L 3 DISP PAN DISP. 11-12 SENSOR OUT ALARM CLEAR 11-15-18 10:27AM
L 9 STP SUMP UNLEADED SUMP SENSOR OUT ALARM CLEAR 11-15-18 10:27AM
L 8 DISP PAN DISP. 15-16 SENSOR OUT ALARM CLEAR 11-15-18 10:27AM
L 2 DISP PAN DISP. 3-4 SENSOR OUT ALARM CLEAR 11-15-18 10:27AM
L 7 DISP PAN DISP. 13-14 SENSOR OUT ALARM CLEAR 11-15-18 10:27AM
L 1 DISP PAN DISP. 1-2 SENSOR OUT ALARM CLEAR 11-15-18 10:27AM
L 6 DISP PAN DISP 5-6 SENSOR OUT ALARM CLEAR 11-15-18 10:27AM
L10 STP SUMP SUPREME SUMP SENSOR OUT ALARM ALARM 11-15-18 10:27AM
L 5 DISP PAN DISP. 9-10 SENSOR OUT ALARM CLEAR 11-15-18 10:27AM
L 9 STP SUMP UNLEADED SUMP SENSOR OUT ALARM ALARM 11-15-18 10:27AM
L 8 DISP PAN DISP. 15-16 SENSOR OUT ALARM ALARM 11-15-18 10:27AM
L 7 DISP PAN DISP. 13-14 SENSOR OUT ALARM ALARM 11-15-18 10:27AM
L14 ANNULAR DIESEL ANNULAR FUEL ALARM ALARM 11-15-18 10:27AM
L 6 DISP PAN DISP 5-6 SENSOR OUT ALARM ALARM 11-15-18 10:27AM
L13 ANNULAR SUPREME ANNULAR FUEL ALARM ALARM 11-15-18 10:27AM
L 5 DISP PAN DISP. 9-10 SENSOR OUT ALARM ALARM 11-15-18 10:27AM
L12 ANNULAR UNLEADED ANNULAR FUEL ALARM ALARM 11-15-18 10:27AM
L 4 DISP PAN DISP. 7-8 SENSOR OUT ALARM ALARM 11-15-18 10:27AM
L 3 DISP PAN DISP. 11-12 SENSOR OUT ALARM ALARM 11-15-18 10:27AM
L11 STP SUMP DIESEL SUMP SENSOR OUT ALARM ALARM 11-15-18 10:27AM
L 2 DISP PAN DISP. 3-4 SENSOR OUT ALARM ALARM 11-15-18 10:27AM
L 1 DISP PAN DISP. 1-2 SENSOR OUT ALARM ALARM 11-15-18 10:27AM
T 1 TANK UNLEADED 87 PROBE OUT CLEAR 11-15-18 10:23AM
T 1 TANK UNLEADED 87 PROBE OUT ALARM 11-15-18 10:22AM
T 1 TANK UNLEADED 87 OVERFILL ALARM CLEAR 11-15-18 10:22AM
T 1 TANK UNLEADED 87 OVERFILL ALARM ALARM 11-15-18 10:20AM
T 2 TANK SUPREME 91 PROBE OUT CLEAR 11-15-18 10:18AM
T 2 TANK SUPREME 91 PROBE OUT ALARM 11-15-18 10:18AM
T 2 TANK SUPREME 91 OVERFILL ALARM CLEAR 11-15-18 10:18AM
T 2 TANK SUPREME 91 OVERFILL ALARM ALARM 11-15-18 10:16AM
T 3 TANK DIESEL PROBE OUT CLEAR 11-15-18 10:13AM
T 3 TANK DIESEL PROBE OUT ALARM 11-15-18 10:12AM
T 3 TANK DIESEL OVERFILL ALARM CLEAR 11-15-18 10:12AM
L14 ANNULAR DIESEL ANNULAR FUEL ALARM CLEAR 11-15-18 10:12AM
T 3 TANK DIESEL OVERFILL ALARM ALARM 11-15-18 10:10AM
T 3 TANK DIESEL PROBE OUT CLEAR 11-15-18 10:10AM
T 3 TANK DIESEL PROBE OUT ALARM 11-15-18 10:08AM
L14 ANNULAR DIESEL ANNULAR FUEL ALARM ALARM 11-15-18 10:07AM
L13 ANNULAR SUPREME ANNULAR FUEL ALARM CLEAR 11-15-18 10:06AM
T 1 TANK UNLEADED 87 PROBE OUT CLEAR 11-15-18 10:03AM
T 1 TANK UNLEADED 87 PROBE OUT ALARM 11-15-18 10:03AM
T 2 TANK SUPREME 91 PROBE OUT CLEAR 11-15-18 10:01AM
T 2 TANK SUPREME 91 PROBE OUT ALARM 11-15-18 10:00AM
L13 ANNULAR SUPREME ANNULAR FUEL ALARM ALARM 11-15-18 9:59AM
I11200
NOV 15, 2018 11:21 AM
286917 SPARKLING IMA
2301 H ST.
BAKERSFIELD,CA 93301
661-324-8455
NON-PRIORITY ALARM HISTORY
ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME
T 3 TANK DIESEL LOW TEMP WARNING CLEAR 11-15-18 10:13AM
T 3 TANK DIESEL LOW TEMP WARNING ALARM 11-15-18 10:13AM
T 3 TANK DIESEL HIGH PRODUCT ALARM CLEAR 11-15-18 10:12AM
T 3 TANK DIESEL HIGH PRODUCT ALARM ALARM 11-15-18 10:10AM
SYSTEM PRINTER ERROR CLEAR 11-13-18 2:30PM
SYSTEM PAPER OUT CLEAR 11-13-18 2:30PM
SYSTEM PRINTER ERROR ALARM 11-13-18 2:30PM
SYSTEM PAPER OUT ALARM 11-13-18 2:30PM
SYSTEM PRINTER ERROR CLEAR 11-13-18 2:30PM
SYSTEM PAPER OUT CLEAR 11-13-18 2:30PM
SYSTEM PRINTER ERROR ALARM 11-13-18 2:30PM
SYSTEM PAPER OUT ALARM 11-13-18 2:30PM
SYSTEM PRINTER ERROR CLEAR 11-13-18 2:30PM
SYSTEM PAPER OUT CLEAR 11-13-18 2:30PM
SYSTEM PRINTER ERROR ALARM 11-13-18 2:30PM
SYSTEM PAPER OUT ALARM 11-13-18 2:30PM
OTHER ISD GROSS PRES WARN CLEAR 11-11-18 2:35PM
OTHER ISD GROSS PRES WARN ALARM 11-11-18 10:02AM
SYSTEM PRINTER ERROR CLEAR 11-09-18 9:46AM
SYSTEM PRINTER ERROR ALARM 11-09-18 9:46AM
SYSTEM PRINTER ERROR CLEAR 11-08-18 3:43PM
SYSTEM PAPER OUT CLEAR 11-08-18 3:43PM
SYSTEM PRINTER ERROR ALARM 11-08-18 3:42PM
SYSTEM PAPER OUT ALARM 11-08-18 3:42PM
SYSTEM PRINTER ERROR CLEAR 11-07-18 7:26AM
SYSTEM PAPER OUT CLEAR 11-07-18 7:26AM
SYSTEM PRINTER ERROR ALARM 11-07-18 7:25AM
SYSTEM PAPER OUT ALARM 11-07-18 7:25AM
SYSTEM PRINTER ERROR CLEAR 11-07-18 7:25AM
SYSTEM PAPER OUT CLEAR 11-07-18 7:25AM
SYSTEM PRINTER ERROR ALARM 11-07-18 7:24AM
SYSTEM PAPER OUT ALARM 11-07-18 7:24AM
OTHER ISD GROSS PRES WARN CLEAR 11-04-18 10:18AM
OTHER ISD GROSS PRES WARN ALARM 11-04-18 10:03AM
SYSTEM PRINTER ERROR CLEAR 10-22-18 12:29PM
SYSTEM PAPER OUT CLEAR 10-22-18 12:29PM
SYSTEM PAPER OUT ALARM 10-22-18 12:29PM
SYSTEM PRINTER ERROR ALARM 10-22-18 12:29PM
h12 OTHER FP12: BLEND3 DEGRD COLLECT WARN CLEAR 10-16-18 12:15PM
h12 OTHER FP12: BLEND3 DEGRD COLLECT WARN ALARM 10-10-18 10:02AM
SYSTEM PRINTER ERROR CLEAR 10-10-18 4:30AM
SYSTEM PAPER OUT CLEAR 10-10-18 4:30AM
SYSTEM PRINTER ERROR ALARM 10-10-18 4:30AM
SYSTEM PAPER OUT ALARM 10-10-18 4:30AM
h 3 OTHER FP3: BLEND3 DEGRD COLLECT WARN CLEAR 10-05-18 10:00AM
h 3 OTHER FP3: BLEND3 DEGRD COLLECT WARN ALARM 10-04-18 10:02AM
h 1 OTHER FP1: BLEND3 DEGRD COLLECT WARN CLEAR 10-04-18 10:00AM
h 1 OTHER FP1: BLEND3 DEGRD COLLECT WARN ALARM 10-03-18 10:02AM
SYSTEM PRINTER ERROR CLEAR 9-24-18 2:59PM
SYSTEM PAPER OUT CLEAR 9-24-18 2:59PM
I20600
NOV 15, 2018 11:21 AM
286917 SPARKLING IMA
2301 H ST.
BAKERSFIELD,CA 93301
661-324-8455
TANK ALARM HISTORY
TANK 1 UNLEADED 87
OVERFILL ALARM NOV 15, 2018 10:20 AM
NOV 13, 2018 12:56 AM
NOV 6, 2018 11:25 PM
LOW PRODUCT ALARM NOV 19, 2013 9:27 AM
JUN 26, 2013 4:22 PM
HIGH PRODUCT ALARM DEC 1, 2014 11:11 AM
MAR 7, 2013 5:09 AM
FEB 25, 2013 4:03 AM
INVALID FUEL LEVEL NOV 19, 2015 9:08 AM
NOV 19, 2013 9:27 AM
PROBE OUT NOV 15, 2018 10:22 AM
NOV 15, 2018 10:03 AM
NOV 20, 2017 4:16 PM
DELIVERY NEEDED NOV 20, 2017 3:49 PM
JUL 20, 2017 8:00 PM
AUG 6, 2015 9:47 AM
LOW TEMP WARNING NOV 20, 2017 4:17 PM
NOV 16, 2016 10:22 AM
NOV 16, 2016 9:53 AM
TANK 2 SUPREME 91
OVERFILL ALARM NOV 15, 2018 10:16 AM
DEC 30, 2017 9:13 AM
NOV 15, 2017 10:22 AM
LOW PRODUCT ALARM NOV 16, 2016 9:50 AM
INVALID FUEL LEVEL NOV 19, 2014 9:15 AM
NOV 19, 2014 8:50 AM
NOV 19, 2012 9:00 AM
PROBE OUT NOV 15, 2018 10:18 AM
NOV 15, 2018 10:00 AM
NOV 20, 2017 4:17 PM
DELIVERY NEEDED NOV 20, 2017 4:02 PM
NOV 15, 2017 9:24 AM
NOV 16, 2016 9:50 AM
LOW TEMP WARNING NOV 20, 2017 4:18 PM
NOV 16, 2016 10:25 AM
NOV 16, 2016 9:51 AM
TANK 3 DIESEL
OVERFILL ALARM NOV 15, 2018 10:10 AM
NOV 15, 2017 10:18 AM
NOV 16, 2016 10:26 AM
LOW PRODUCT ALARM NOV 19, 2015 9:05 AM
HIGH PRODUCT ALARM NOV 15, 2018 10:10 AM
NOV 15, 2017 10:18 AM
INVALID FUEL LEVEL NOV 16, 2016 9:51 AM
PROBE OUT NOV 15, 2018 10:12 AM
NOV 15, 2018 10:08 AM
NOV 15, 2017 10:19 AM
DELIVERY NEEDED NOV 16, 2016 9:50 AM
NOV 19, 2015 9:05 AM
LOW TEMP WARNING NOV 15, 2018 10:13 AM
NOV 19, 2015 9:50 AM
NOV 19, 2014 9:18 AM
I38200
NOV 15, 2018 11:21 AM
I30200
NOV 15, 2018 11:21 AM
286917 SPARKLING IMA
2301 H ST.
BAKERSFIELD,CA 93301
661-324-8455
LIQUID ALARM HISTORY REPORT
SENSOR LOCATION
1 DISP. 1-2
NOV 15, 2018 10:27 AM SENSOR OUT ALARM
NOV 15, 2018 9:52 AM FUEL ALARM
NOV 15, 2017 10:47 AM SENSOR OUT ALARM
2 DISP. 3-4
NOV 15, 2018 10:27 AM SENSOR OUT ALARM
NOV 15, 2018 9:51 AM FUEL ALARM
NOV 15, 2017 10:48 AM SENSOR OUT ALARM
3 DISP. 11-12
NOV 15, 2018 10:27 AM SENSOR OUT ALARM
NOV 15, 2018 9:47 AM FUEL ALARM
NOV 15, 2017 10:48 AM SENSOR OUT ALARM
4 DISP. 7-8
NOV 15, 2018 10:27 AM SENSOR OUT ALARM
NOV 15, 2018 9:49 AM FUEL ALARM
NOV 15, 2017 10:48 AM SENSOR OUT ALARM
5 DISP. 9-10
NOV 15, 2018 10:27 AM SENSOR OUT ALARM
NOV 15, 2018 9:48 AM FUEL ALARM
NOV 15, 2017 10:47 AM SENSOR OUT ALARM
6 DISP 5-6
NOV 15, 2018 10:27 AM SENSOR OUT ALARM
NOV 15, 2018 9:50 AM FUEL ALARM
NOV 15, 2017 10:47 AM SENSOR OUT ALARM
7 DISP. 13-14
NOV 15, 2018 10:27 AM SENSOR OUT ALARM
NOV 15, 2018 9:47 AM FUEL ALARM
NOV 15, 2017 10:48 AM SENSOR OUT ALARM
8 DISP. 15-16
NOV 15, 2018 10:27 AM SENSOR OUT ALARM
NOV 15, 2018 9:46 AM FUEL ALARM
NOV 15, 2017 10:48 AM SENSOR OUT ALARM
9 UNLEADED SUMP
NOV 15, 2018 10:27 AM SENSOR OUT ALARM
NOV 15, 2018 9:41 AM FUEL ALARM
NOV 15, 2017 10:47 AM SENSOR OUT ALARM
10 SUPREME SUMP
NOV 15, 2018 10:27 AM SENSOR OUT ALARM
NOV 15, 2018 9:40 AM FUEL ALARM
NOV 15, 2017 10:47 AM SENSOR OUT ALARM
11 DIESEL SUMP
NOV 15, 2018 10:27 AM SENSOR OUT ALARM
NOV 15, 2018 9:39 AM FUEL ALARM
NOV 15, 2017 10:47 AM SENSOR OUT ALARM
12 UNLEADED ANNULAR
NOV 15, 2018 10:27 AM FUEL ALARM
SEP 12, 2018 6:16 PM FUEL ALARM
SEP 12, 2018 12:24 PM FUEL ALARM
13 SUPREME ANNULAR
NOV 15, 2018 10:27 AM FUEL ALARM
NOV 15, 2018 9:59 AM FUEL ALARM
NOV 15, 2017 10:47 AM FUEL ALARM
14 DIESEL ANNULAR
NOV 15, 2018 10:27 AM FUEL ALARM
NOV 15, 2018 10:07 AM FUEL ALARM
NOV 15, 2017 10:47 AM FUEL ALARM
I31600
NOV 15, 2018 11:22 AM
286917 SPARKLING IMA
2301 H ST.
BAKERSFIELD,CA 93301
661-324-8455
SMART SENSOR ALARM HISTORY REPORT
SENSOR LOCATION
1 FM 1-2
AUG 23, 2013 3:29 PM COMMUNICATION ALARM
2 FM 3-4
3 FM 5-6
4 FM 7-8
5 FM 9-10
MAY 19, 2014 10:48 PM COMMUNICATION ALARM
6 FM 11-12
7 FM 13-14
8 PRESSURE SENSOR
NOV 16, 2016 10:36 AM COMMUNICATION ALARM
JUL 23, 2010 8:06 AM COMMUNICATION ALARM
9 FM 15-16
I40200
NOV 15, 2018 11:22 AM
I40300
NOV 15, 2018 11:22 AM
I34200
NOV 15, 2018 11:22 AM
I34700
NOV 15, 2018 11:22 AM
IV0100
NOV 15, 2018 11:22 AM
286917 SPARKLING IMA
2301 H ST.
BAKERSFIELD,CA 93301
661-324-8455
ISD ALARM STATUS REPORT
EVR TYPE: VACUUM ASSIST
ISD TYPE: 01.03
VAPOR PROCESSOR TYPE: NONE
OVERALL STATUS :PASS EVR VAPOR COLLECTION :PASS
EVR VAPOR CONTAINMENT :PASS
ISD MONITOR UP-TIME :100%
EVR/ISD PASS TIME :100%
WARNING ALARMS
DATE TIME DESCRIPTION READING VALUE
18-11-11 10:02:35 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.47
18-11-04 10:03:27 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 1.84
18-10-16 10:03:57 A/L RATIO DEGRADATION FP12 BLEND3 0.80
18-10-15 10:04:28 A/L RATIO DEGRADATION FP12 BLEND3 0.79
18-10-14 10:04:21 A/L RATIO DEGRADATION FP12 BLEND3 0.79
18-10-13 10:03:01 A/L RATIO DEGRADATION FP12 BLEND3 0.80
18-10-12 10:02:29 A/L RATIO DEGRADATION FP12 BLEND3 0.78
18-10-11 10:02:09 A/L RATIO DEGRADATION FP12 BLEND3 0.77
18-10-10 10:02:40 A/L RATIO DEGRADATION FP12 BLEND3 0.76
18-10-04 10:02:40 A/L RATIO DEGRADATION FP 3 BLEND3 0.80
FAILURE ALARMS
DATE TIME DESCRIPTION READING VALUE
16-10-13 10:03:26 A/L RATIO GROSS BLOCKAGE FP 7 BLEND3 BLKD
15-04-02 10:01:23 A/L RATIO GROSS BLOCKAGE FP12 BLEND3 BLKD
11-08-16 10:03:25 A/L RATIO GROSS BLOCKAGE FP 6 BLEND3 BLKD
10-10-08 10:01:09 SETUP SELFTEST
MISSING HOSE(S)
10-10-07 10:01:09 SETUP SELFTEST
MISSING HOSE(S)
10-10-06 10:01:09 SETUP SELFTEST
MISSING HOSE(S)
10-10-05 10:01:09 SETUP SELFTEST
MISSING HOSE(S)
10-10-04 10:01:10 SETUP SELFTEST
MISSING HOSE(S)
10-10-03 10:01:09 SETUP SELFTEST
MISSING HOSE(S)
10-10-02 10:01:09 SETUP SELFTEST
MISSING HOSE(S)
SHUTDOWN & MISCELLANEOUS EVENTS
DATE TIME DESCRIPTION ACTION/NAME
18-11-15 10:28:16 READINESS ISD:PP EVR:NN EVR READINESS PENDING
18-11-15 10:28:16 ISD STARTUP
18-11-15 10:28:05 ISD SHUTDOWN
18-11-15 10:02:43 READINESS ISD:PP EVR:NP EVR READINESS PENDING
18-11-14 10:02:24 READINESS ISD:PP EVR:NP EVR READINESS PENDING
18-11-13 10:02:43 READINESS ISD:PP EVR:NP EVR READINESS PENDING
18-11-12 10:02:54 READINESS ISD:PP EVR:NP EVR READINESS PENDING
18-11-11 14:35:13 CONTAINMENT GROSS & DEGRD TEST MANUALLY CLEARED
18-11-11 10:02:35 READINESS ISD:PP EVR:NF CHECK EVR SYSTEM
18-11-10 10:03:26 READINESS ISD:PP EVR:NP EVR READINESS PENDING
&(56 &DOLIRUQLD(QYLURQPHQWDO5HSRUWLQJ6\VWHP,' ,GHQWLILFDWLRQ867 8QGHUJURXQG6WRUDJH7DQN,&& ,QWHUQDWLRQDO&RGH&RXQFLO
81 ZZZXQLGRFVRUJ5HY
81'(5*5281'6725$*(7$1.
63,//&217$,1(57(67,1*5(3257)2503DJHRI
7\SHRI$FWLRQ,QVWDOODWLRQ7HVW5HSDLU7HVW0RQWK7HVW
, )$&,/,7<,1)250$7,21
&(56,''DWHRI6SLOO&RQWDLQHU7HVW
%XVLQHVV1DPH(Same as Facility Name or DBA-Doing Business As)
%XVLQHVV6LWH$GGUHVV &LW\ =,3&RGH
,, 81'(5*5281'6725$*(7$1.6(59,&(7(&+1,&,$1,1)250$7,21
1DPHRI8676HUYLFH7HFKQLFLDQ3HUIRUPLQJWKH7HVW(Print as shown on the ICC Certification.) 3KRQH
&RQWUDFWRU7DQN7HVWHU/LFHQVH ,&&&HUWLILFDWLRQ ,&&&HUWLILFDWLRQ([SLUDWLRQ'DWH
6SLOO&RQWDLQHU7HVWLQJ7UDLQLQJDQG&HUWLILFDWLRQV(List applicable certifications.)
,,, 63,//&217$,1(57(67,1*,1)250$7,21
7HVW0HWKRG8VHG0DQXIDFWXUHU*XLGHOLQHV(Specify)
,QGXVWU\&RGHRU(QJLQHHULQJ6WDQGDUG (Specify)
(QJLQHHUHG0HWKRG(Specify)
Attach the testing procedures and all documentation required to determine the results.RI$WWDFKHG3DJHV
7$1.,'(By tank number, stored product, etc.)
6SLOO&RQWDLQHU0DQXIDFWXUHU
0HWKRGRI&DWKRGLF3URWHFWLRQ1RQ0HWDOOLF1RQ0HWDOOLF1RQ0HWDOOLF1RQ0HWDOOLF
,VRODWLRQ,VRODWLRQ,VRODWLRQ,VRODWLRQ
2WKHU(Specify in V.)2WKHU(Specify in V.)2WKHU(Specify in V.)2WKHU(Specify in V.)
,QVLGH'LDPHWHURI6SLOO&RQWDLQHU(Inches)
'HSWKRI6SLOO&RQWDLQHU(Inches)
'RHVWKHVSLOOFRQWDLQHUKDYHDJDOORQFDSDFLW\"<HV1R<HV1R<HV1R<HV1R
0HWKRGWR.HHS6SLOO&RQWDLQHU(PSW\'UDLQ9DOYH'UDLQ9DOYH'UDLQ9DOYH'UDLQ9DOYH
2QVLWH3XPS2QVLWH3XPS2QVLWH3XPS2QVLWH3XPS
2WKHU(Specify in V.)2WKHU(Specify in V.)2WKHU(Specify in V.)2WKHU(Specify in V.)
,9 6800$5<2)7(67,1*5(68/76
6SLOO&RQWDLQHU7HVW5HVXOWV3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLO
9 &200(176
Any items marked “Fail” above must be explained in this section. Any additional comments may also be provided here.
9, &(57,),&$7,21%<8676(59,&(7(&+1,&,$1&21'8&7,1*7+,67(67,1*
,KHUHE\FHUWLI\WKDWWKHVSLOOFRQWDLQHUVZHUHWHVWHGLQDFFRUGDQFHZLWK&DOLIRUQLD&RGHRI5HJXODWLRQV7LWOH'LYLVLRQ
&KDSWHU6HFWLRQDQGDOOWKHLQIRUPDWLRQFRQWDLQHGKHUHLQLVDFFXUDWH
8676HUYLFH7HFKQLFLDQ6LJQDWXUH
If the facility has more components than this form accommodates, additional copies of this page may be attached.
Bakersfield 93301
804904 8374998 11/14/2019
Franklin fueling 1008973709
PEI 1200
1
87
Phil-tite
12.00”
18.00”
91
Phil-tite
12.00”
18.00”
Diesel
Phil-tite
12.00”
18.00”
Frank Amestoy (800) 339-9930
10123120 11/15/2018
Sparkling Image Car Wash
2301 H Street
SWRCB, January 2006
Spill Bucket Testing Report Form
This form is intended for use by contractors performing annual testing of UST spill containment structures. The completed form and
printouts from tests (if applicable), should be provided to the facility owner/operator for submittal to the local regulatory agency.
1. FACILITY INFORMATION
Facility Name: Date of Testing:
Facility Address:
Facility Contact: Phone:
Date Local Agency Was Notified of Testing :
Name of Local Agency Inspector (if present during testing):
2. TESTING CONTRACTOR INFORMATION
Company Name:
Technician Conducting Test:
Credentials1: CSLB Contractor ICC Service Tech. SWRCB Tank Tester Other (Specify) __________________
License Number(s):
3. SPILL BUCKET TESTING INFORMATION
Test Method Used: Hydrostatic Vacuum Other
Test Equipment Used: Equipment Resolution:
Identify Spill Bucket (By Tank
Number, Stored Product, etc.)
1234
Bucket Installation Type: Direct Bury
Contained in Sump
Direct Bury
Contained in Sump
Direct Bury
Contained in Sump
Direct Bury
Contained in Sump
Bucket Diameter:
Bucket Depth:
Wait time between applying
vacuum/water and start of test:
Test Start Time (TI):
Initial Reading (RI):
Test End Time (TF):
Final Reading (RF):
Test Duration (TF –TI):
Change in Reading (RF -RI):
Pass/Fail Threshold or
Criteria:
Test Result: Pass Fail Pass Fail Pass Fail Pass Fail
Comments –(include information on repairs made prior to testing, and recommended follow-up for failed tests)
CERTIFICATION OF TECHNICIAN RESPONSIBLE FOR CONDUCTING THIS TESTING
I hereby certify that all the information contained in this report is true, accurate, and in full compliance with legal requirements.
Technician’s Signature:________________________________________________ Date:_________________________
1 State laws and regulations do not currently require testing to be performed by a qualified contractor. However, local requirements
may be more stringent.
Sparkling Image Car Wash 11/15/2018
2301 H Street Bakersfield 93301
Soo Ann (470) 650-1177
10/18/2018
Kris Karns
Confidence UST Services, Inc.
Frank Amestoy
804904 8374998
Lake test 0.0625”
87 91 Diesel
12.00” 12.00” 12.00”
18.00” 18.00” 18.00”
30 minutes 30 minutes 30 minutes
9:30am 9:30am 9:30am
17.00” 17.00” 17.00”
10:30am 10:30am 10:30am
17.00” 17.00” 17.00”
60 minutes 60 minutes 60 minutes
0.00” 0.00” 0.00”
0.0625” 0.0625” 0.0625”
11/15/2018
✔✔
✔
✔✔✔
✔✔✔