Loading...
HomeMy WebLinkAbout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ame as Facility Name or DBA-Doing Business As) %XVLQHVV6LWH$GGUHVV &LW\ =,3&RGH ,, 81'(5*5281'6725$*(7$1.6(59,&(7(&+1,&,$1,1)250$7,21 1DPHRI&RPSDQ\3HUIRUPLQJWKH&HUWLILFDWLRQ 3KRQH 0DLOLQJ$GGUHVV 1DPHRI8676HUYLFH7HFKQLFLDQ3HUIRUPLQJWKH&HUWLILFDWLRQ(Print as shown on the ICC Certification) &RQWUDFWRU7DQN7HVWHU/LFHQVH ,&&&HUWLILFDWLRQ ,&&&HUWLILFDWLRQ([SLUDWLRQ'DWH 0RQLWRULQJ6\VWHP7UDLQLQJDQG&HUWLILFDWLRQV(List all applicable certifications.) ([SLUDWLRQ'DWH ,,, 5(68/762)7(67,1*6(59,&,1* Indicate and attach the following reports if the monitoring equipment is capable of generating either.<11$0RQLWRULQJ6\VWHP6HWXS$ODUP+LVWRU\5HSRUW :DVDQ\PRQLWRULQJHTXLSPHQWUHSODFHG" (If “Yes,” identify the specific devices replaced and list the manufacturer and model for all replacement parts in section IV below.) :DVGDPDJHGHEULVRUOLTXLGIRXQGLQVLGHDQ\VHFRQGDU\FRQWDLQPHQWV\VWHPV" (If “Yes,” describe what was found in section IV below.) ,VDOOPRQLWRULQJHTXLSPHQWRSHUDWLRQDOSHUPDQXIDFWXUHU¶VVSHFLILFDWLRQV" (If “No,” describe why in section IV below.) ,9 &200(176 If directed to use this section, describe how and when the issues were or will be corrected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parkling Image Car Wash 2301 H Street Bakersfield 93301 16250 Meacham Road, Bakersfield, CA 93314 Frank Amestoy 804904 8374998 11/14/2019 Veeder-root B64403 8/3/2020 Franklin fueling 1008973709 4/12/2019 Confidence UST Services, Inc. (800) 339-9930 ,' ,GHQWLILFDWLRQ6: 6LQJOH:DOOHG93+ 9DFXXP3UHVVXUH+\GURVWDWLF//' /LQH/HDN'HWHFWRU 81 ZZZXQLGRFVRUJ 5HY 81'(5*5281'6725$*(7$1. 021,725,1*6<67(0&(57,),&$7,21)250 3DJHRI  9, ,19(1725<2)(48,30(17&(57,),(' A separate Monitoring System Certification Form must be prepared for each monitoring system control panel. 0DNHRI0RQLWRULQJ6\VWHP&RQWURO3DQHO  0RGHORI0RQLWRULQJ6\VWHP&RQWURO3DQHO  6RIWZDUH9HUVLRQ,QVWDOOHG  Check the appropriate boxes to indicate specific equipment inspected/serviced. 0RQLWRULQJ'HYLFH8VHG'HYLFH0RGHO0RQLWRULQJ'HYLFH8VHG'HYLFH0RGHO 7$1.,' (By tank number, stored product, etc.) 7$1.,' (By tank number, stored product, etc.) ,Q7DQN*DXJLQJ(SW Tank),Q7DQN*DXJLQJ(SW Tank) $QQXODU6SDFHRU9DXOW6HQVRU$QQXODU6SDFHRU9DXOW6HQVRU 93+6HQVRU93+6HQVRU 3URGXFW3LSLQJ3URGXFW3LSLQJ 0HFKDQLFDO//'0HFKDQLFDO//' (OHFWURQLF//'(OHFWURQLF//' 93+6HQVRU 3LSLQJ 93+6HQVRU 3LSLQJ  6XPS6HQVRU6XPS6HQVRU 93+6HQVRU 6XPS 93+6HQVRU 6XPS  )LOO3LSLQJ)LOO3LSLQJ 93+6HQVRU 3LSLQJ 93+6HQVRU 3LSLQJ  6XPS6HQVRU6XPS6HQVRU 93+6HQVRU 6XPS 93+6HQVRU 6XPS  9HQW3LSLQJ9HQW3LSLQJ 93+6HQVRU 3LSLQJ 93+6HQVRU 3LSLQJ  6XPS6HQVRU6XPS6HQVRU 93+6HQVRU 6XPS 93+6HQVRU 6XPS  9DSRU5HFRYHU\3LSLQJ9DSRU5HFRYHU\3LSLQJ 93+6HQVRU 3LSLQJ 93+6HQVRU 3LSLQJ  6XPS6HQVRU6XPS6HQVRU 93+6HQVRU 6XPS 93+6HQVRU 6XPS  0RQLWRULQJ'HYLFH8VHG 'HYLFH0RGHO0RQLWRULQJ'HYLFH8VHG 'HYLFH0RGHO 7$1.,' (By tank number, stored product, etc.) 7$1.,' (By tank number, stored product, etc.) ,Q7DQN*DXJLQJ(SW Tank),Q7DQN*DXJLQJ(SW Tank) $QQXODU6SDFHRU9DXOW6HQVRU$QQXODU6SDFHRU9DXOW6HQVRU 93+6HQVRU93+6HQVRU 3URGXFW3LSLQJ3URGXFW3LSLQJ 0HFKDQLFDO//'0HFKDQLFDO//' (OHFWURQLF//'(OHFWURQLF//' 93+6HQVRU 3LSLQJ 93+6HQVRU 3LSLQJ  6XPS6HQVRU6XPS6HQVRU 93+6HQVRU 6XPS 93+6HQVRU 6XPS  )LOO3LSLQJ)LOO3LSLQJ 93+6HQVRU 3LSLQJ 93+6HQVRU 3LSLQJ  6XPS6HQVRU6XPS6HQVRU 93+6HQVRU 6XPS 93+6HQVRU 6XPS  9HQW3LSLQJ9HQW3LSLQJ 93+6HQVRU 3LSLQJ 93+6HQVRU 3LSLQJ  6XPS6HQVRU6XPS6HQVRU 93+6HQVRU 6XPS 93+6HQVRU 6XPS  9DSRU5HFRYHU\3LSLQJ9DSRU5HFRYHU\3LSLQJ 93+6HQVRU 3LSLQJ 93+6HQVRU 3LSLQJ  6XPS6HQVRU6XPS6HQVRU 93+6HQVRU 6XPS 93+6HQVRU 6XPS  Veeder-root TLS-350 330.01 T1: 87 12,000 84390-107 Mosier brothers vacuum sensor FX1V 794380-208 T2: 91 12,000 84390-107 Mosier brothers vacuum sensor FX1V 794380-208 T3: Diesel 12,000 84390-107 Mosier brothers vacuum sensor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pecify in section VII.)2WKHU(Specify in section VII.) 2WKHU0RQLWRUHG&RPSRQHQW,'2WKHU0RQLWRUHG&RPSRQHQW,' 2WKHU(Specify in section VII.)2WKHU(Specify in section VII.) 2WKHU0RQLWRUHG&RPSRQHQW,'2WKHU0RQLWRUHG&RPSRQHQW,' 2WKHU(Specify in section VII.)2WKHU(Specify in section VII.) Include information for every underground storage tank component monitored by this monitoring system control panel. If the monitoring system control panel monitors more components than this form accommodates, additional copies of these pages may be attached. 9,, &200(176 Use this section to provide additional comments about the inventory of the equipment certified.  1/2 794380-208 3/4 794380-208 5/6 794380-208 7/8 794380-208 9/10 794380-208 11/12 794380-208 13/14 794380-208 15/16 794380-208 < <HV1 1R1$ 1RW$SSOLFDEOH 81 ZZZXQLGRFVRUJ 5HY 81'(5*5281'6725$*(7$1. 021,725,1*6<67(0&(57,),&$7,21)250 3DJHRI  9,,, 021,725,1*6<67(0$1'352*5$00,1* This section must be completed if a monitoring panel is used to perform leak detection monitoring.<11$ $UHWKHYLVXDODQGDXGLEOHDODUPVRSHUDWLRQDO" :HUHDOOVHQVRUVYLVXDOO\LQVSHFWHGIRUNLQNVDQGEUHDNVLQWKHFDEOHVDQGIRUUHVLGXDOEXLOGXSWRHQVXUHWKDWIORDWVPRYHIUHHO\ IXQFWLRQDOO\WHVWHGDQGFRQILUPHGRSHUDWLRQDO" :HUHDOOVHQVRUVLQVWDOOHGDWORZHVWSRLQWRIVHFRQGDU\FRQWDLQPHQWDQGSRVLWLRQHGVRWKDWRWKHUHTXLSPHQWZLOOQRWLQWHUIHUHZLWK WKHLUSURSHURSHUDWLRQ" :DVPRQLWRULQJV\VWHPVHWXSUHYLHZHGWRHQVXUHSURSHUVHWWLQJV" :DVWKHPRQLWRULQJSDQHO¶VEDFNXSEDWWHU\YLVXDOO\LQVSHFWHGIXQFWLRQDOO\WHVWHGDQGFRQILUPHGRSHUDWLRQDO" 'RHVWKHIORZRIIXHOVWRSDWWKHGLVSHQVHULIDOHDNLVGHWHFWHGLQWKHXQGHUGLVSHQVHUFRQWDLQPHQW" 'RHVWKHWXUELQHDXWRPDWLFDOO\VKXWGRZQLIWKHSLSLQJVHFRQGDU\FRQWDLQPHQWPRQLWRULQJV\VWHPIDLOVWRRSHUDWHRULVHOHFWULFDOO\ GLVFRQQHFWHG" 'RHVWKHWXUELQHDXWRPDWLFDOO\VKXWGRZQLIWKHSLSLQJVHFRQGDU\FRQWDLQPHQWPRQLWRULQJV\VWHPGHWHFWVDOHDN" :KLFKVHQVRUVLQLWLDWHSRVLWLYHVKXWGRZQ"(Check all that apply.)6XPS8QGHU'LVSHQVHU&RQWDLQPHQW ,IDODUPVDUHUHOD\HGWRDUHPRWHPRQLWRULQJVWDWLRQLVDOOFRPPXQLFDWLRQVHTXLSPHQW HJPRGHP RSHUDWLRQDO" For any answer of “N” above, describe in Section IX how and when these deficiencies were or will be corrected. ,; &200(176 ; ,17$1.*$8*,1*7(67,1* &KHFNWKLVER[LIWDQNJDXJLQJLVXVHGRQO\IRULQYHQWRU\FRQWURO(Do not complete this section.) <11$&KHFNWKLVER[LI12WDQNJDXJLQJHTXLSPHQWLVLQVWDOOHG (Do not complete this section.) This section must be completed if in-tank gauging is used to perform leak detection monitoring. +DVDOOLQSXWZLULQJEHHQLQVSHFWHGIRUNLQNVDQGEUHDNVLQWKHFDEOHVDQGIRUSURSHUHQWU\DQGWHUPLQDWLRQLQFOXGLQJWHVWLQJIRU JURXQGIDXOWV" :HUHDOOLQWDQNJDXJLQJSUREHVYLVXDOO\LQVSHFWHGIRUGDPDJHDQGUHVLGXHEXLOGXSWRHQVXUHWKDWIORDWVPRYHIUHHO\IXQFWLRQDOO\ WHVWHGDQGFRQILUPHGRSHUDWLRQDO" :DVDFFXUDF\RIV\VWHP¶VSURGXFWOHYHOUHDGLQJVWHVWHG" :DVDFFXUDF\RIV\VWHP¶VZDWHUOHYHOUHDGLQJVWHVWHG" :HUHDOOSUREHVUHLQVWDOOHGSURSHUO\" :HUHDOOLWHPVRQWKHHTXLSPHQWPDQXIDFWXUHU¶VPDLQWHQDQFHFKHFNOLVWFRPSOHWHG" For any answer of “N” above, describe in Section XI how and when these deficiencies were or will be corrected. ;, &200(176 Sensors in 87STP/91 STP were not installed at the lowest point. I made hangers and install them at lowest point on product side. *3+ *DOORQV3HU+RXU< <HV1 1R1$ 1RW$SSOLFDEOH93+ 9DFXXP3UHVVXUH+\GURVWDWLF,' ,GHQWLILFDWLRQ 81 ZZZXQLGRFVRUJ5HY 81'(5*5281'6725$*(7$1. 021,725,1*6<67(0&(57,),&$7,21)250 3DJHRI  ;,, /,1(/($.'(7(&7257(67,1* &KHFNWKLVER[LIOLQHOHDNGHWHFWRUV //' DUH127LQVWDOOHG(Do not complete this section.)<11$This section must be completed if LLDs are installed. :DVDOHDNVLPXODWHGWRYHULI\//'SHUIRUPDQFH" (Check all that apply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¶VPDLQWHQDQFHFKHFNOLVWFRPSOHWHG" :HUHDOO//'VFRQILUPHGRSHUDWLRQDOZLWKLQUHJXODWRU\UHTXLUHPHQWV" For any answer of “N” above, describe in Section XIII how and when these issues were or will be corrected. ;,,, &200(176 ;,9 9$&88035(6685(+<'5267$7,&021,725,1*(48,30(177(67,1* &KHFNWKLVER[LI93+PRQLWRULQJLV127XVHG(Do not complete this section.) This section must be completed if VPH monitoring is used to perform leak detection monitoring. 6\VWHP7\SH 0DUNDOOWKDWDSSO\ 9DFXXP3UHVVXUH+\GURVWDWLF 6HQVRU,'&RPSRQHQW 6 0RQLWRUHG%\7KLV6HQVRU 6HQVRU)XQFWLRQDOLW\ 7HVW ,QWHUVWLWLDO&RPPXQLFDWLRQ 7HVW 3DVV )DLO 3DVV )DLO 3DVV)DLO3DVV)DLO 3DVV)DLO3DVV)DLO 3DVV)DLO3DVV)DLO 3DVV)DLO3DVV)DLO 3DVV)DLO3DVV)DLO 3DVV)DLO3DVV)DLO 3DVV)DLO3DVV)DLO 3DVV)DLO3DVV)DLO 3DVV)DLO3DVV)DLO 3DVV)DLO3DVV)DLO 3DVV)DLO3DVV)DLO +RZZDVLQWHUVWLWLDOFRPPXQLFDWLRQYHULILHG"6LPXODWHG/HDNDW)DU(QGVRIWKH,QWHUVWLWLDO6SDFH9LVXDO,QVSHFWLRQ 2WKHU(Describe the method in section XV below.)*DXJH :DVWKHYDFXXPRUSUHVVXUHUHVWRUHGWRRSHUDWLQJOHYHOVLQDOOLQWHUVWLWLDOVSDFHV"<HV1R(Describe the reason in section XV below.) For any answer of “Fail” above, describe in Section XV how and when these issues were or will be corrected. ;9 &200(176 L12: 87 annular L13: 91 annular L14: Diesel annular Held vacuum on annular side, released vacuum to gauge and to tubing side. when re-connected annular space to tubing and gauge vacuum came back to normal. verified communication Sparkling chevron setup Responses Received: 200 286917 SPARKLING IMA 2301 H ST. BAKERSFIELD,CA 93301 661-324-8455 NOV 15, 2018 9:08 AM TANK PRODUCT GALLONS INCHES WATER DEG F ULLAGE 1 UNLEADED 87 10549 78.87 1.0 65.1 1451 2 SUPREME 91 6243 49.52 0.0 66.0 5757 3 DIESEL 2797 27.21 0.0 82.8 9203 I90500 NOV 15, 2018 9:08 AM SOFTWARE REVISION LEVEL VERSION 330.01 SOFTWARE# 346330-100-B CREATED - 10.07.23.17.25 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS CSLD BIR FUEL MANAGER ISD PLLD 0.10 AUTO 0.20 REPETITIV WPLLD 0.10 AUTO 0.20 REPETITIV I50500 NOV 15, 2018 9:08 AM SYSTEM TYPE AND LANGUAGE FLAG SYSTEM UNITS U.S. SYSTEM LANGUAGE ENGLISH SYSTEM DATE/TIME FORMAT MON DD YYYY HH:MM:SS xM I50201 NOV 15, 2018 9:08 AM SHIFT TIME 1 : 12:00 AM I50202 NOV 15, 2018 9:08 AM SHIFT TIME 2 : 6:00 AM I50203 NOV 15, 2018 9:08 AM SHIFT TIME 3 : 12:00 PM I50204 NOV 15, 2018 9:08 AM SHIFT TIME 4 : 6:00 PM I54600 NOV 15, 2018 9:08 AM TANK PER TST NEEDED WRN: DISABLED I54900 NOV 15, 2018 9:08 AM TANK ANN TST NEEDED WRN: DISABLED I55300 NOV 15, 2018 9:08 AM LINE RE-ENABLE METHOD PASS LINE TEST I55600 NOV 15, 2018 9:08 AM LINE PER TST NEEDED WRN: DISABLED I55900 NOV 15, 2018 9:08 AM LINE ANN TST NEEDED WRN: DISABLED I50D00 NOV 15, 2018 9:08 AM PRINT TC VOLUMES ENABLED I50E00 NOV 15, 2018 9:08 AM TEMP COMPENSATION VALUE (DEG F ): 60.0 I60B00 NOV 15, 2018 9:08 AM STICK HEIGHT OFFSET ENABLE STATUS DISABLED I51400 NOV 15, 2018 9:08 AM H-PROTOCOL DATA FORMAT HEIGHT I51A01 NOV 15, 2018 9:08 AM DAYLIGHT SAVING TIME ENABLED OFF I51B00 NOV 15, 2018 9:08 AM DAYLIGHT SAVING TIME START DATE MAR WEEK 2 SUN 2:00 AM END DATE NOV WEEK 1 SUN 2:00 AM I51600 NOV 15, 2018 9:08 AM RE-DIRECT LOCAL PRINTOUT DISABLED I50400 NOV 15, 2018 9:08 AM 232 SECURITY CODE PORT SECURITY CODE STATUS 1 000000 DISABLED 2 000000 DISABLED 3 000000 DISABLED 4 000000 DISABLED 5 000000 DISABLED 6 000000 DISABLED I21900 NOV 15, 2018 9:08 AM TANK CHART SECURITY DISABLED I5BD00 NOV 15, 2018 9:09 AM CUSTOM ALARM LABELS DISABLED I56000 NOV 15, 2018 9:09 AM MASS/DENSITY DISABLED I88101 NOV 15, 2018 9:09 AM PORT SETTINGS: COMM BOARD : 1 (EDIM ) RS-232 SECURITY CODE : DISABLED I88102 NOV 15, 2018 9:09 AM PORT SETTINGS: COMM BOARD : 2 (RS-232) BAUD RATE : 9600 PARITY : NONE STOP BIT : 1 STOP DATA LENGTH: 8 DATA RS-232 SECURITY CODE : DISABLED I88103 NOV 15, 2018 9:09 AM PORT SETTINGS: COMM BOARD : 3 (S-SAT ) BAUD RATE : 9600 PARITY : NONE STOP BIT : 1 STOP DATA LENGTH: 8 DATA RS-232 SECURITY CODE : DISABLED DTR NORMAL STATE: HIGH I88104 NOV 15, 2018 9:09 AM I88105 NOV 15, 2018 9:09 AM I88106 NOV 15, 2018 9:09 AM I52000 NOV 15, 2018 9:09 AM RECEIVER AUTO DIAL TYPE & START TIME RCVR LOCATION LABEL DIAL TYPE START TIME 1 ON DATE OCT 19, 2015 6:14 AM 2 ON DATE OCT 19, 2015 6:14 AM 3 ON DATE OCT 19, 2015 6:14 AM 4 ON DATE OCT 19, 2015 6:14 AM 5 ON DATE OCT 19, 2015 6:14 AM 6 ON DATE OCT 19, 2015 6:14 AM 7 ON DATE OCT 19, 2015 6:14 AM 8 VEEDER ROOT (FMS) ON DATE JUL 26, 2017 10:38 AM I60100 NOV 15, 2018 9:09 AM TANK CONFIGURATION DEVICE LABEL CONFIGURED 1 UNLEADED 87 ON 2 SUPREME 91 ON 3 DIESEL ON 4 OFF I60200 NOV 15, 2018 9:09 AM TANK PRODUCT LABEL TANK PRODUCT LABEL 1 UNLEADED 87 2 SUPREME 91 3 DIESEL 4 I60300 NOV 15, 2018 9:09 AM TANK PRODUCT CODE TANK PRODUCT LABEL 1 UNLEADED 87 1 2 SUPREME 91 2 3 DIESEL 3 4 4 I60900 NOV 15, 2018 9:09 AM TANK THERMAL COEFFICIENT TANK PRODUCT LABEL 1 UNLEADED 87 0.000700 2 SUPREME 91 0.000700 3 DIESEL 0.000450 4 0.000000 I60700 NOV 15, 2018 9:09 AM TANK DIAMETER TANK PRODUCT LABEL INCHES 1 UNLEADED 87 96.00 2 SUPREME 91 96.00 3 DIESEL 96.00 4 0.00 I60A00 NOV 15, 2018 9:09 AM TANK FULL VOLUME TANK PRODUCT LABEL TANK PROFILE GALLONS 1 UNLEADED 87 1 PT 12000 2 SUPREME 91 1 PT 12000 3 DIESEL 1 PT 12000 4 1 PT 0 I60400 NOV 15, 2018 9:09 AM TANK FULL VOLUME TANK PRODUCT LABEL GALLONS 1 UNLEADED 87 12000 2 SUPREME 91 12000 3 DIESEL 12000 4 0 I60500 NOV 15, 2018 9:09 AM TANK 4 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 UNLEADED 87 12000 0 0 0 2 SUPREME 91 12000 0 0 0 3 DIESEL 12000 0 0 0 4 0 0 0 0 I60600 NOV 15, 2018 9:09 AM TANK 20 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 UNLEADED 87 12000 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 SUPREME 91 12000 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3 DIESEL 12000 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 I61500 NOV 15, 2018 9:09 AM TANK PRODUCT LABEL METER DATA 1 UNLEADED 87 NO 2 SUPREME 91 NO 3 DIESEL NO 4 NO I62F00 NOV 15, 2018 9:09 AM MAG PROBE FLOAT SIZE TANK PRODUCT LABEL FLOAT SIZE: 1 UNLEADED 87 4.0 IN. 2 SUPREME 91 4.0 IN. 3 DIESEL 4.0 IN. I62700 NOV 15, 2018 9:09 AM TANK HIGH WATER WARNING LIMIT TANK PRODUCT LABEL INCHES 1 UNLEADED 87 2.0 2 SUPREME 91 2.0 3 DIESEL 2.0 9999FF1B I62400 NOV 15, 2018 9:09 AM TANK HIGH WATER LEVEL LIMIT TANK PRODUCT LABEL INCHES 1 UNLEADED 87 3.0 2 SUPREME 91 3.0 3 DIESEL 3.0 I62800 NOV 15, 2018 9:09 AM TANK MAXIMUM VOLUME LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 87 12000 2 SUPREME 91 12000 3 DIESEL 12000 4 0 I62300 NOV 15, 2018 9:09 AM TANK OVERFILL LEVEL LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 87 10800 2 SUPREME 91 10800 3 DIESEL 10800 4 0 I62200 NOV 15, 2018 9:09 AM TANK HIGH PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 87 11400 2 SUPREME 91 11400 3 DIESEL 11400 4 0 I62900 NOV 15, 2018 9:09 AM TANK DELIVERY REQUIRED LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 87 1200 2 SUPREME 91 1200 3 DIESEL 1200 4 0 I62100 NOV 15, 2018 9:09 AM TANK LOW PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 87 451 2 SUPREME 91 451 3 DIESEL 451 4 0 I62600 NOV 15, 2018 9:09 AM TANK LEAK ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 87 99 2 SUPREME 91 99 3 DIESEL 99 4 99 I62500 NOV 15, 2018 9:09 AM TANK SUDDEN LOSS LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 87 99 2 SUPREME 91 99 3 DIESEL 99 4 99 I60800 NOV 15, 2018 9:09 AM TANK TILT TANK PRODUCT LABEL INCHES 1 UNLEADED 87 -3.00 2 SUPREME 91 -2.00 3 DIESEL 0.00 4 0.00 I60B00 NOV 15, 2018 9:09 AM STICK HEIGHT OFFSET ENABLE STATUS DISABLED I60C00 NOV 15, 2018 9:09 AM TANK STICK HEIGHT OFFSET TANK PRODUCT LABEL INCHES 1 UNLEADED 87 0.00 2 SUPREME 91 0.00 3 DIESEL 0.00 4 0.00 I61200 NOV 15, 2018 9:09 AM TANK MANIFOLDED PARTNERS TANK PRODUCT LABEL SIPHON MANIFOLDED TANKS LINE MANIFOLDED TANKS 1 UNLEADED 87 NONE NONE 2 SUPREME 91 NONE NONE 3 DIESEL NONE NONE 4 NONE NONE I63600 NOV 15, 2018 9:09 AM PERIODIC LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 UNLEADED 87 120 2 SUPREME 91 120 3 DIESEL 120 4 0 I62A00 NOV 15, 2018 9:09 AM ANNUAL LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 UNLEADED 87 120 2 SUPREME 91 120 3 DIESEL 120 4 0 I62C00 NOV 15, 2018 9:09 AM TANK PERIODIC TEST TYPE TANK PRODUCT LABEL PERIODIC TEST TYPE 1 UNLEADED 87 STANDARD 2 SUPREME 91 STANDARD 3 DIESEL STANDARD 4 STANDARD I62D00 NOV 15, 2018 9:09 AM TANK LEAK TEST FAIL ALARMS TANK PRODUCT LABEL 1 UNLEADED 87 GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 2 SUPREME 91 GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 3 DIESEL GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 4 GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED I63100 NOV 15, 2018 9:09 AM TANK LEAK TEST AVERAGING TANK PRODUCT LABEL ANNUAL PERIODIC 1 UNLEADED 87 OFF OFF 2 SUPREME 91 OFF OFF 3 DIESEL OFF OFF 4 OFF OFF I63000 NOV 15, 2018 9:09 AM IN-TANK LEAK TEST NOTIFY TANK PRODUCT LABEL TANK TEST NOTIFY: 1 UNLEADED 87 OFF 2 SUPREME 91 OFF 3 DIESEL OFF 4 OFF I63200 NOV 15, 2018 9:09 AM TANK TEST SIPHON BREAK TANK PRODUCT LABEL SIPHON BREAK 1 UNLEADED 87 OFF 2 SUPREME 91 OFF 3 DIESEL OFF 4 OFF I61000 NOV 15, 2018 9:09 AM TANK DELIVERY DELAY TANK PRODUCT LABEL 1 UNLEADED 87 1 2 SUPREME 91 1 3 DIESEL 1 4 1 I63A00 NOV 15, 2018 9:09 AM LOW LEVEL PUMP THRESHOLD FOR SEQUENTIAL LINE MANIFOLD TANK PRODUCT LABEL PUMP THRESHOLD 1 UNLEADED 87 10.00% 2 SUPREME 91 10.00% 3 DIESEL 10.00% 4 10.00% I61100 NOV 15, 2018 9:09 AM LEAK TEST METHOD - - - - - - - - - - - - TEST ON DATE : ALL TANK JUL 23, 2010 START TIME : DISABLED TEST RATE :0.20 GAL/HR DURATION : 2 HOURS TST EARLY STOP:DISABLED I61300 NOV 15, 2018 9:09 AM CSLD PROBABLITY OF DETECTION I61400 NOV 15, 2018 9:09 AM CSLD CLIMATE FACTOR I61600 NOV 15, 2018 9:09 AM TANK PRODUCT LABEL CAL UPDATE 1 UNLEADED 87 IMMEDIATE 2 SUPREME 91 IMMEDIATE 3 DIESEL IMMEDIATE 4 IMMEDIATE I61A00 NOV 15, 2018 9:09 AM IN-TANK LEAK TEST EARLY STOP TANK PRODUCT LABEL TST EARLY STOP: 1 UNLEADED 87 DISABLED 2 SUPREME 91 DISABLED 3 DIESEL DISABLED 4 DISABLED I61B00 NOV 15, 2018 9:09 AM IN-TANK LEAK GROSS TEST AUTO-CONFIRM I61C00 NOV 15, 2018 9:09 AM CSLD REPORT ONLY I62B00 NOV 15, 2018 9:09 AM TANK LAST ANNUAL TEST TANK PRODUCT LABEL DATE 1 UNLEADED 87 ??? 0, 0 2 SUPREME 91 ??? 0, 0 3 DIESEL ??? 0, 0 4 ??? 0, 0 I63300 NOV 15, 2018 9:09 AM LEAK TEST REPORT FORMAT: NORMAL I63400 NOV 15, 2018 9:09 AM RECONCILIATION WARNING LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 87 0 2 SUPREME 91 0 3 DIESEL 0 4 0 I63500 NOV 15, 2018 9:09 AM RECONCILIATION ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 87 1 2 SUPREME 91 1 3 DIESEL 1 4 1 I63900 NOV 15, 2018 9:09 AM ACCU CHART END SHAPE FACTOR TANK PRODUCT LABEL 1 UNLEADED 87 END FACTOR: NONE 2 SUPREME 91 END FACTOR: NONE 3 DIESEL END FACTOR: NONE 4 END FACTOR: NONE I78000 NOV 15, 2018 9:09 AM I77700 NOV 15, 2018 9:09 AM I77800 NOV 15, 2018 9:09 AM I78C00 NOV 15, 2018 9:09 AM I78300 NOV 15, 2018 9:09 AM I78F00 NOV 15, 2018 9:09 AM I78700 NOV 15, 2018 9:09 AM I70200 NOV 15, 2018 9:09 AM LIQUID LABEL DEVICE LABEL 1 DISP. 1-2 2 DISP. 3-4 3 DISP. 11-12 4 DISP. 7-8 5 DISP. 9-10 6 DISP 5-6 7 DISP. 13-14 8 DISP. 15-16 9 UNLEADED SUMP 10 SUPREME SUMP 11 DIESEL SUMP 12 UNLEADED ANNULAR 13 SUPREME ANNULAR 14 DIESEL ANNULAR 15 UNLEADED ANN 16 17 UNL ANNULAR 18 19 UNL ANNULAR 20 21 22 23 24 BUBBA SENSOR I70300 NOV 15, 2018 9:09 AM LIQUID TYPE SENSOR LOCATION TYPE 1 DISP. 1-2 TRI-STATE (SINGLE FLOAT) 2 DISP. 3-4 TRI-STATE (SINGLE FLOAT) 3 DISP. 11-12 TRI-STATE (SINGLE FLOAT) 4 DISP. 7-8 TRI-STATE (SINGLE FLOAT) 5 DISP. 9-10 TRI-STATE (SINGLE FLOAT) 6 DISP 5-6 TRI-STATE (SINGLE FLOAT) 7 DISP. 13-14 TRI-STATE (SINGLE FLOAT) 8 DISP. 15-16 TRI-STATE (SINGLE FLOAT) 9 UNLEADED SUMP TRI-STATE (SINGLE FLOAT) 10 SUPREME SUMP TRI-STATE (SINGLE FLOAT) 11 DIESEL SUMP TRI-STATE (SINGLE FLOAT) 12 UNLEADED ANNULAR NORMALLY CLOSED 13 SUPREME ANNULAR NORMALLY CLOSED 14 DIESEL ANNULAR NORMALLY CLOSED 15 UNLEADED ANN NORMALLY CLOSED 16 TRI-STATE (SINGLE FLOAT) 17 UNL ANNULAR NORMALLY CLOSED 18 TRI-STATE (SINGLE FLOAT) 19 UNL ANNULAR NORMALLY CLOSED 20 TRI-STATE (SINGLE FLOAT) 21 TRI-STATE (SINGLE FLOAT) 22 TRI-STATE (SINGLE FLOAT) 23 TRI-STATE (SINGLE FLOAT) 24 BUBBA SENSOR NORMALLY CLOSED I70400 NOV 15, 2018 9:09 AM LIQUID CATEGORY SENSOR LOCATION CATEGORY 1 DISP. 1-2 DISPENSER PAN 2 DISP. 3-4 DISPENSER PAN 3 DISP. 11-12 DISPENSER PAN 4 DISP. 7-8 DISPENSER PAN 5 DISP. 9-10 DISPENSER PAN 6 DISP 5-6 DISPENSER PAN 7 DISP. 13-14 DISPENSER PAN 8 DISP. 15-16 DISPENSER PAN 9 UNLEADED SUMP STP SUMP 10 SUPREME SUMP STP SUMP 11 DIESEL SUMP STP SUMP 12 UNLEADED ANNULAR ANNULAR SPACE 13 SUPREME ANNULAR ANNULAR SPACE 14 DIESEL ANNULAR ANNULAR SPACE 15 UNLEADED ANN ANNULAR SPACE 16 OTHER SENSORS 17 UNL ANNULAR ANNULAR SPACE 18 OTHER SENSORS 19 UNL ANNULAR ANNULAR SPACE 20 OTHER SENSORS 21 OTHER SENSORS 22 OTHER SENSORS 23 OTHER SENSORS 24 BUBBA SENSOR OTHER SENSORS I74200 NOV 15, 2018 9:09 AM I74300 NOV 15, 2018 9:09 AM I74400 NOV 15, 2018 9:09 AM I74700 NOV 15, 2018 9:09 AM I74800 NOV 15, 2018 9:09 AM I74900 NOV 15, 2018 9:09 AM I7BC00 NOV 15, 2018 9:09 AM I80200 NOV 15, 2018 9:09 AM I80300 NOV 15, 2018 9:09 AM I80400 NOV 15, 2018 9:09 AM I80700 NOV 15, 2018 9:09 AM RELAY LABEL DEVICE LABEL 1 UNLEADED 87 2 SUPREME 3 DIESEL 4 OVERFILL ALARM 5 REMOTE ALARMS 6 REMOTE ALARM 7 8 I80900 NOV 15, 2018 9:09 AM RELAY ORIENTATION RELAY DESIGNATION ORIENTATION 1 UNLEADED 87 NORMALLY CLOSED 2 SUPREME NORMALLY CLOSED 3 DIESEL NORMALLY CLOSED 4 OVERFILL ALARM NORMALLY OPEN 5 REMOTE ALARMS NORMALLY CLOSED 6 REMOTE ALARM NORMALLY CLOSED 7 NORMALLY OPEN 8 NORMALLY OPEN I80B00 NOV 15, 2018 9:09 AM RELAY TANK ASSIGNMENT RELAY DESIGNATION TANK 1 UNLEADED 87 1 2 SUPREME 2 3 DIESEL 3 4 OVERFILL ALARM NONE 5 REMOTE ALARMS NONE 6 REMOTE ALARM NONE 7 NONE 8 NONE I80A00 NOV 15, 2018 9:09 AM RELAY TYPE RELAY DESIGNATION TYPE 1 UNLEADED 87 STANDARD 2 SUPREME STANDARD 3 DIESEL STANDARD 4 OVERFILL ALARM STANDARD 5 REMOTE ALARMS STANDARD 6 REMOTE ALARM STANDARD 7 STANDARD 8 STANDARD I80C00 NOV 15, 2018 9:10 AM I80800 NOV 15, 2018 9:10 AM RELAY SETUP REPORT R 1:UNLEADED 87 TYPE: STANDARD NORMALLY CLOSED TANK #: 1 IN-TANK ALARMS T 1:LEAK ALARM LIQUID SENSOR ALMS L 1:FUEL ALARM L 2:FUEL ALARM L 3:FUEL ALARM L 4:FUEL ALARM L 5:FUEL ALARM L 6:FUEL ALARM L 7:FUEL ALARM L 8:FUEL ALARM L 9:FUEL ALARM L 1:SENSOR OUT ALARM L 2:SENSOR OUT ALARM L 3:SENSOR OUT ALARM L 4:SENSOR OUT ALARM L 5:SENSOR OUT ALARM L 6:SENSOR OUT ALARM L 7:SENSOR OUT ALARM L 8:SENSOR OUT ALARM L 9:SENSOR OUT ALARM L 1:SHORT ALARM L 2:SHORT ALARM L 3:SHORT ALARM L 4:SHORT ALARM L 5:SHORT ALARM L 6:SHORT ALARM L 7:SHORT ALARM L 8:SHORT ALARM L 9:SHORT ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD VP PRES FAIL ISD VP STATUS FAIL ISD HOSE ALARMS ALL:GROSS COLLECT FAIL ALL:DEGRD COLLECT FAIL ALL:FLOW COLLECT FAIL R 2:SUPREME TYPE: STANDARD NORMALLY CLOSED TANK #: 2 IN-TANK ALARMS T 2:LEAK ALARM T 2:LOW PRODUCT ALARM LIQUID SENSOR ALMS L 1:FUEL ALARM L 2:FUEL ALARM L 3:FUEL ALARM L 4:FUEL ALARM L 5:FUEL ALARM L 6:FUEL ALARM L 7:FUEL ALARM L 8:FUEL ALARM L10:FUEL ALARM L 1:SENSOR OUT ALARM L 2:SENSOR OUT ALARM L 3:SENSOR OUT ALARM L 4:SENSOR OUT ALARM L 5:SENSOR OUT ALARM L 6:SENSOR OUT ALARM L 7:SENSOR OUT ALARM L 8:SENSOR OUT ALARM L10:SENSOR OUT ALARM L 1:SHORT ALARM L 2:SHORT ALARM L 3:SHORT ALARM L 4:SHORT ALARM L 5:SHORT ALARM L 6:SHORT ALARM L 7:SHORT ALARM L 8:SHORT ALARM L10:SHORT ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD VP PRES FAIL ISD VP STATUS FAIL ISD HOSE ALARMS ALL:GROSS COLLECT FAIL ALL:DEGRD COLLECT FAIL ALL:FLOW COLLECT FAIL R 3:DIESEL TYPE: STANDARD NORMALLY CLOSED TANK #: 3 IN-TANK ALARMS T 3:LEAK ALARM T 3:LOW PRODUCT ALARM LIQUID SENSOR ALMS L 1:FUEL ALARM L 4:FUEL ALARM L 5:FUEL ALARM L 8:FUEL ALARM L11:FUEL ALARM L 1:SENSOR OUT ALARM L 4:SENSOR OUT ALARM L 5:SENSOR OUT ALARM L 8:SENSOR OUT ALARM L11:SENSOR OUT ALARM L 1:SHORT ALARM L 4:SHORT ALARM L 5:SHORT ALARM L 8:SHORT ALARM L11:SHORT ALARM R 4:OVERFILL ALARM TYPE: STANDARD NORMALLY OPEN TANK #: NONE IN-TANK ALARMS ALL:OVERFILL ALARM ALL:HIGH PRODUCT ALARM ALL:MAX PRODUCT ALARM R 5:REMOTE ALARMS TYPE: STANDARD NORMALLY CLOSED TANK #: NONE IN-TANK ALARMS ALL:LEAK ALARM ALL:HIGH WATER ALARM ALL:OVERFILL ALARM ALL:LOW PRODUCT ALARM ALL:SUDDEN LOSS ALARM ALL:HIGH PRODUCT ALARM ALL:INVALID FUEL LEVEL ALL:PROBE OUT ALL:HIGH WATER WARNING ALL:DELIVERY NEEDED ALL:MAX PRODUCT ALARM ALL:GROSS TEST FAIL ALL:PERIODIC TEST FAIL ALL:ANNUAL TEST FAIL ALL:PER TST NEEDED WRN LIQUID SENSOR ALMS L 1:FUEL ALARM L 2:FUEL ALARM L 3:FUEL ALARM L 4:FUEL ALARM L 5:FUEL ALARM L 6:FUEL ALARM L 7:FUEL ALARM L 8:FUEL ALARM L 9:FUEL ALARM L10:FUEL ALARM L11:FUEL ALARM L12:FUEL ALARM L13:FUEL ALARM L14:FUEL ALARM L15:FUEL ALARM L16:FUEL ALARM L 1:SENSOR OUT ALARM L 2:SENSOR OUT ALARM L 3:SENSOR OUT ALARM L 4:SENSOR OUT ALARM L 5:SENSOR OUT ALARM L 6:SENSOR OUT ALARM L 7:SENSOR OUT ALARM L 8:SENSOR OUT ALARM L 9:SENSOR OUT ALARM L10:SENSOR OUT ALARM L11:SENSOR OUT ALARM L12:SENSOR OUT ALARM L13:SENSOR OUT ALARM L14:SENSOR OUT ALARM L15:SENSOR OUT ALARM L16:SENSOR OUT ALARM L 1:SHORT ALARM L 2:SHORT ALARM L 3:SHORT ALARM L 4:SHORT ALARM L 5:SHORT ALARM L 6:SHORT ALARM L 7:SHORT ALARM L 8:SHORT ALARM L 9:SHORT ALARM L10:SHORT ALARM L11:SHORT ALARM L12:SHORT ALARM L13:SHORT ALARM L14:SHORT ALARM L15:SHORT ALARM L16:SHORT ALARM SMARTSENSOR ALARMS ALL:SETUP DATA WARNING ALL:COMMUNICATION ALARM ALL:SENSOR FAULT ALARM ALL:SENSOR FAULT WARN ISD SITE ALARMS ISD STAGE I WARN ISD GROSS PRES WARN ISD GROSS PRES FAIL ISD DEGRD PRES WARN ISD DEGRD PRES FAIL ISD VAPOR LEAK WARN ISD VAPOR LEAK FAIL ISD VP PRES WARN ISD VP PRES FAIL ISD VP STATUS WARN ISD VP STATUS FAIL MISSING RELAY SETUP MISSING HOSE SETUP MISSING TANK SETUP MISS VAPOR FLOW MTR MISS VAPOR PRES SEN MISSING VP INPUT ISD SETUP WARN ISD SETUP FAIL ISD SENSOR OUT WARN ISD SENSOR OUT FAIL ISD HOSE ALARMS ALL:GROSS COLLECT WARN ALL:GROSS COLLECT FAIL ALL:DEGRD COLLECT WARN ALL:DEGRD COLLECT FAIL ALL:FLOW COLLECT WARN ALL:FLOW COLLECT FAIL ALL:AIRFLOW MTR SETUP VAPOR FLW MTR ALMS ALL:CHK VAPOR FLOW MTR R 6:REMOTE ALARM TYPE: STANDARD NORMALLY CLOSED TANK #: NONE IN-TANK ALARMS ALL:OVERFILL ALARM ALL:HIGH PRODUCT ALARM ALL:MAX PRODUCT ALARM LIQUID SENSOR ALMS L 1:FUEL ALARM L 2:FUEL ALARM L 3:FUEL ALARM L 4:FUEL ALARM L 5:FUEL ALARM L 6:FUEL ALARM L 7:FUEL ALARM L 8:FUEL ALARM L 9:FUEL ALARM L10:FUEL ALARM L11:FUEL ALARM L12:FUEL ALARM L13:FUEL ALARM L14:FUEL ALARM L15:FUEL ALARM L16:FUEL ALARM L 1:SENSOR OUT ALARM L 2:SENSOR OUT ALARM L 3:SENSOR OUT ALARM L 4:SENSOR OUT ALARM L 5:SENSOR OUT ALARM L 6:SENSOR OUT ALARM L 7:SENSOR OUT ALARM L 8:SENSOR OUT ALARM L 9:SENSOR OUT ALARM L10:SENSOR OUT ALARM L11:SENSOR OUT ALARM L12:SENSOR OUT ALARM L13:SENSOR OUT ALARM L14:SENSOR OUT ALARM L15:SENSOR OUT ALARM L16:SENSOR OUT ALARM L 1:SHORT ALARM L 2:SHORT ALARM L 3:SHORT ALARM L 4:SHORT ALARM L 5:SHORT ALARM L 6:SHORT ALARM L 7:SHORT ALARM L 8:SHORT ALARM L 9:SHORT ALARM L10:SHORT ALARM L11:SHORT ALARM L12:SHORT ALARM L13:SHORT ALARM L14:SHORT ALARM L15:SHORT ALARM L16:SHORT ALARM SMARTSENSOR ALARMS ALL:COMMUNICATION ALARM ISD SITE ALARMS ISD STAGE I WARN ISD GROSS PRES WARN ISD GROSS PRES FAIL ISD DEGRD PRES WARN ISD DEGRD PRES FAIL ISD VAPOR LEAK WARN ISD VAPOR LEAK FAIL ISD VP PRES WARN ISD VP PRES FAIL ISD VP STATUS WARN ISD VP STATUS FAIL MISSING RELAY SETUP MISSING HOSE SETUP ISD SENSOR OUT WARN ISD SENSOR OUT FAIL ISD HOSE ALARMS ALL:GROSS COLLECT WARN ALL:GROSS COLLECT FAIL ALL:DEGRD COLLECT WARN ALL:DEGRD COLLECT FAIL ALL:FLOW COLLECT WARN ALL:FLOW COLLECT FAIL ALL:AIRFLOW MTR SETUP VAPOR FLW MTR ALMS ALL:CHK VAPOR FLOW MTR R 7: TYPE: STANDARD NORMALLY OPEN TANK #: NONE - NO ALARM ASSIGNMENTS - R 8: TYPE: STANDARD NORMALLY OPEN TANK #: NONE - NO ALARM ASSIGNMENTS - I79000 NOV 15, 2018 9:10 AM EDIM:1 VR:349643-001-B TD:97.10.27.11.25 I79100 NOV 15, 2018 9:10 AM I72300 NOV 15, 2018 9:10 AM 286917 SPARKLING IMA 2301 H ST. BAKERSFIELD,CA 93301 661-324-8455 SMARTSENSOR ASSIGNMENT DEVICE LABEL CATEGORY 01 FM 1-2 AIR FLOW METER 02 FM 3-4 AIR FLOW METER 03 FM 5-6 AIR FLOW METER 04 FM 7-8 AIR FLOW METER 05 FM 9-10 AIR FLOW METER 06 FM 11-12 AIR FLOW METER 07 FM 13-14 AIR FLOW METER 08 PRESSURE SENSOR VAPOR PRESSURE 09 FM 15-16 AIR FLOW METER 10 UNKNOWN 11 UNKNOWN 12 UNKNOWN 13 UNKNOWN 14 UNKNOWN 15 UNKNOWN 16 UNKNOWN 17 UNKNOWN 18 UNKNOWN 19 UNKNOWN 20 UNKNOWN 21 UNKNOWN 22 UNKNOWN 23 UNKNOWN 24 UNKNOWN 25 UNKNOWN 26 UNKNOWN 27 UNKNOWN 28 UNKNOWN 29 UNKNOWN 30 UNKNOWN 31 UNKNOWN 32 UNKNOWN 33 UNKNOWN 34 UNKNOWN 35 UNKNOWN 36 UNKNOWN 37 UNKNOWN 38 UNKNOWN 39 UNKNOWN 40 UNKNOWN IV4E00 NOV 15, 2018 9:10 AM 286917 SPARKLING IMA 2301 H ST. BAKERSFIELD,CA 93301 661-324-8455 EVR/ISD SETUP TYPE: VACUUM ASSIST VACUUM ASSIST TYPE: HEALY VAC IV4F00 NOV 15, 2018 9:10 AM 286917 SPARKLING IMA 2301 H ST. BAKERSFIELD,CA 93301 661-324-8455 NOZZLE A/L RANGE A/L RATIO: 0.95 - 1.15 IV4000 NOV 15, 2018 9:10 AM 286917 SPARKLING IMA 2301 H ST. BAKERSFIELD,CA 93301 661-324-8455 VAPOR PROCESSOR TYPE NONE IV4700 NOV 15, 2018 9:10 AM 286917 SPARKLING IMA 2301 H ST. BAKERSFIELD,CA 93301 661-324-8455 ASSESSMENT TIME START TIME: 10:00 AM TIME DELAY MINUTES: 1 IV5200 NOV 15, 2018 9:10 AM 286917 SPARKLING IMA 2301 H ST. BAKERSFIELD,CA 93301 661-324-8455 ACCEPT HIGH ORVR: NO IV4A00 NOV 15, 2018 9:10 AM 286917 SPARKLING IMA 2301 H ST. BAKERSFIELD,CA 93301 661-324-8455 ISD HOSE TABLE HOSE FP FP AFM HOSE ID ID LABEL ID LABEL 01 01 01 01 BLEND3 02 02 02 01 BLEND3 03 03 03 02 BLEND3 04 04 04 02 BLEND3 05 05 05 03 BLEND3 06 06 06 03 BLEND3 07 07 07 04 BLEND3 08 08 08 04 BLEND3 09 09 09 05 BLEND3 10 16 10 05 BLEND3 11 17 11 06 BLEND3 12 18 12 06 BLEND3 13 19 13 07 BLEND3 14 20 14 07 BLEND3 15 21 15 08 BLEND3 16 22 16 08 BLEND3 IV4B00 NOV 15, 2018 9:10 AM 286917 SPARKLING IMA 2301 H ST. BAKERSFIELD,CA 93301 661-324-8455 PRODUCT/HOSE MAP TABLE FP AFID M1/H1 M2/H2 M3/H3 M4/H4 01 01 01/01 02/01 09/01 xx/xx 02 01 01/02 09/02 02/02 xx/xx 03 02 01/03 09/03 02/03 xx/xx 04 02 01/04 09/04 02/04 xx/xx 05 03 01/05 09/05 02/05 xx/xx 06 03 01/06 09/06 02/06 xx/xx 07 04 01/07 09/07 02/07 xx/xx 08 04 01/08 09/08 02/08 xx/xx 09 05 01/09 09/09 02/09 xx/xx 16 05 01/10 09/10 02/10 xx/xx 17 06 01/11 09/11 02/11 xx/xx 18 06 01/12 09/12 02/12 xx/xx 19 07 01/13 09/13 02/13 xx/xx 20 07 01/14 09/14 02/14 xx/xx 21 08 01/15 09/15 02/15 xx/xx 22 08 01/16 09/16 02/16 xx/xx IV4900 NOV 15, 2018 9:10 AM 286917 SPARKLING IMA 2301 H ST. BAKERSFIELD,CA 93301 661-324-8455 LABEL TABLE ID LABEL 01 UNASSIGNED 02 BLEND3 03 REGULAR 04 MID GRADE 05 PREMIUM 06 GOLD 07 BRONZE 08 SILVER 09 BLEND2 10 BLEND4 IV1000 NOV 15, 2018 9:10 AM ISD VERSION: 01.03 Sparkling chevron alarm before Responses Received: I10200 NOV 15, 2018 9:12 AM 286917 SPARKLING IMA 2301 H ST. BAKERSFIELD,CA 93301 661-324-8455 SYSTEM CONFIGURATION SLOT BOARD TYPE POWER ON RESET CURRENT 1 UNUSED 10020167 9640201 2 4 PROBE / G.T. 163726 163566 3 8SMARTSENSOR BD 39558 39532 4 7SMARTSENSOR BD 508286 507689 5 INTERSTITIAL BD 201774 201579 6 INTERSTITIAL BD 202243 202022 7 INTERSTITIAL BD 10002575 200716 8 UNUSED 9996797 9634813 9 RELAY BOARD 14986 15007 10 RELAY BOARD 14964 14962 11 UNUSED 10007979 9644130 12 UNUSED 9986521 9625482 13 UNUSED 9995371 9622463 14 UNUSED 9993588 9634336 15 UNUSED 9983600 9623134 16 UNUSED 10000096 9628076 COMM 1 ELEC DISP INT. 100682 100635 COMM 2 RS232 SERIAL BD 14964 15007 COMM 3 SERIAL SAT BD 9994383 480337 COMM 4 UNUSED 9993287 9630781 COMM 5 UNUSED 9990602 9628657 COMM 6 UNUSED 9984760 9624923 I90200 NOV 15, 2018 9:12 AM SOFTWARE REVISION LEVEL VERSION 330.01 SOFTWARE# 346330-100-B CREATED - 10.07.23.17.25 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS CSLD BIR FUEL MANAGER ISD PLLD 0.10 AUTO 0.20 REPETITIV WPLLD 0.10 AUTO 0.20 REPETITIV I11100 NOV 15, 2018 9:12 AM 286917 SPARKLING IMA 2301 H ST. BAKERSFIELD,CA 93301 661-324-8455 PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME T 1 TANK UNLEADED 87 OVERFILL ALARM CLEAR 11-13-18 1:00AM T 1 TANK UNLEADED 87 OVERFILL ALARM ALARM 11-13-18 12:56AM E 1 OTHER COMMUNICATION ALARM CLEAR 11-12-18 2:04AM E 1 OTHER COMMUNICATION ALARM ALARM 11-12-18 2:02AM T 1 TANK UNLEADED 87 OVERFILL ALARM CLEAR 11-06-18 11:27PM T 1 TANK UNLEADED 87 OVERFILL ALARM ALARM 11-06-18 11:25PM E 1 OTHER COMMUNICATION ALARM CLEAR 11-05-18 2:03AM E 1 OTHER COMMUNICATION ALARM ALARM 11-05-18 2:01AM E 1 OTHER COMMUNICATION ALARM CLEAR 10-29-18 2:02AM E 1 OTHER COMMUNICATION ALARM ALARM 10-29-18 2:00AM D 8 OTHER VEEDER ROOT (FMS) AUTODIAL FAILURE CLEAR 10-24-18 7:44AM D 8 OTHER VEEDER ROOT (FMS) AUTODIAL FAILURE ALARM 10-24-18 2:31AM E 1 OTHER COMMUNICATION ALARM CLEAR 10-22-18 2:05AM E 1 OTHER COMMUNICATION ALARM ALARM 10-22-18 2:02AM E 1 OTHER COMMUNICATION ALARM CLEAR 10-15-18 2:06AM E 1 OTHER COMMUNICATION ALARM ALARM 10-15-18 2:03AM T 1 TANK UNLEADED 87 OVERFILL ALARM CLEAR 10-14-18 10:32AM T 1 TANK UNLEADED 87 OVERFILL ALARM ALARM 10-14-18 10:29AM E 1 OTHER COMMUNICATION ALARM CLEAR 10-08-18 2:07AM E 1 OTHER COMMUNICATION ALARM ALARM 10-08-18 2:04AM E 1 OTHER COMMUNICATION ALARM CLEAR 10-01-18 10:09PM E 1 OTHER COMMUNICATION ALARM ALARM 10-01-18 10:06PM E 1 OTHER COMMUNICATION ALARM CLEAR 10-01-18 2:10AM E 1 OTHER COMMUNICATION ALARM ALARM 10-01-18 2:08AM E 1 OTHER COMMUNICATION ALARM CLEAR 9-24-18 2:05AM E 1 OTHER COMMUNICATION ALARM ALARM 9-24-18 2:03AM T 1 TANK UNLEADED 87 OVERFILL ALARM CLEAR 9-22-18 7:40AM T 1 TANK UNLEADED 87 OVERFILL ALARM ALARM 9-22-18 7:37AM L12 ANNULAR UNLEADED ANNULAR FUEL ALARM CLEAR 9-18-18 10:25AM E 1 OTHER COMMUNICATION ALARM CLEAR 9-17-18 2:10AM E 1 OTHER COMMUNICATION ALARM ALARM 9-17-18 2:08AM L12 ANNULAR UNLEADED ANNULAR FUEL ALARM ALARM 9-12-18 6:16PM L12 ANNULAR UNLEADED ANNULAR FUEL ALARM CLEAR 9-12-18 12:39PM L12 ANNULAR UNLEADED ANNULAR FUEL ALARM ALARM 9-12-18 12:24PM E 1 OTHER COMMUNICATION ALARM CLEAR 9-10-18 2:07AM E 1 OTHER COMMUNICATION ALARM ALARM 9-10-18 2:05AM L12 ANNULAR UNLEADED ANNULAR FUEL ALARM CLEAR 9-04-18 9:12AM E 1 OTHER COMMUNICATION ALARM CLEAR 9-03-18 2:13AM E 1 OTHER COMMUNICATION ALARM ALARM 9-03-18 2:11AM L12 ANNULAR UNLEADED ANNULAR FUEL ALARM ALARM 9-02-18 3:34AM E 1 OTHER COMMUNICATION ALARM CLEAR 8-27-18 2:07AM E 1 OTHER COMMUNICATION ALARM ALARM 8-27-18 2:05AM E 1 OTHER COMMUNICATION ALARM CLEAR 8-20-18 2:07AM E 1 OTHER COMMUNICATION ALARM ALARM 8-20-18 2:05AM E 1 OTHER COMMUNICATION ALARM CLEAR 8-13-18 2:07AM E 1 OTHER COMMUNICATION ALARM ALARM 8-13-18 2:05AM L12 ANNULAR UNLEADED ANNULAR FUEL ALARM CLEAR 8-06-18 12:17PM E 1 OTHER COMMUNICATION ALARM CLEAR 8-06-18 2:08AM E 1 OTHER COMMUNICATION ALARM ALARM 8-06-18 2:05AM L12 ANNULAR UNLEADED ANNULAR FUEL ALARM ALARM 8-04-18 7:59AM I11200 NOV 15, 2018 9:13 AM 286917 SPARKLING IMA 2301 H ST. BAKERSFIELD,CA 93301 661-324-8455 NON-PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME SYSTEM PRINTER ERROR CLEAR 11-13-18 2:30PM SYSTEM PAPER OUT CLEAR 11-13-18 2:30PM SYSTEM PRINTER ERROR ALARM 11-13-18 2:30PM SYSTEM PAPER OUT ALARM 11-13-18 2:30PM SYSTEM PRINTER ERROR CLEAR 11-13-18 2:30PM SYSTEM PAPER OUT CLEAR 11-13-18 2:30PM SYSTEM PRINTER ERROR ALARM 11-13-18 2:30PM SYSTEM PAPER OUT ALARM 11-13-18 2:30PM SYSTEM PRINTER ERROR CLEAR 11-13-18 2:30PM SYSTEM PAPER OUT CLEAR 11-13-18 2:30PM SYSTEM PRINTER ERROR ALARM 11-13-18 2:30PM SYSTEM PAPER OUT ALARM 11-13-18 2:30PM OTHER ISD GROSS PRES WARN CLEAR 11-11-18 2:35PM OTHER ISD GROSS PRES WARN ALARM 11-11-18 10:02AM SYSTEM PRINTER ERROR CLEAR 11-09-18 9:46AM SYSTEM PRINTER ERROR ALARM 11-09-18 9:46AM SYSTEM PRINTER ERROR CLEAR 11-08-18 3:43PM SYSTEM PAPER OUT CLEAR 11-08-18 3:43PM SYSTEM PRINTER ERROR ALARM 11-08-18 3:42PM SYSTEM PAPER OUT ALARM 11-08-18 3:42PM SYSTEM PRINTER ERROR CLEAR 11-07-18 7:26AM SYSTEM PAPER OUT CLEAR 11-07-18 7:26AM SYSTEM PRINTER ERROR ALARM 11-07-18 7:25AM SYSTEM PAPER OUT ALARM 11-07-18 7:25AM SYSTEM PRINTER ERROR CLEAR 11-07-18 7:25AM SYSTEM PAPER OUT CLEAR 11-07-18 7:25AM SYSTEM PRINTER ERROR ALARM 11-07-18 7:24AM SYSTEM PAPER OUT ALARM 11-07-18 7:24AM OTHER ISD GROSS PRES WARN CLEAR 11-04-18 10:18AM OTHER ISD GROSS PRES WARN ALARM 11-04-18 10:03AM SYSTEM PRINTER ERROR CLEAR 10-22-18 12:29PM SYSTEM PAPER OUT CLEAR 10-22-18 12:29PM SYSTEM PAPER OUT ALARM 10-22-18 12:29PM SYSTEM PRINTER ERROR ALARM 10-22-18 12:29PM h12 OTHER FP12: BLEND3 DEGRD COLLECT WARN CLEAR 10-16-18 12:15PM h12 OTHER FP12: BLEND3 DEGRD COLLECT WARN ALARM 10-10-18 10:02AM SYSTEM PRINTER ERROR CLEAR 10-10-18 4:30AM SYSTEM PAPER OUT CLEAR 10-10-18 4:30AM SYSTEM PRINTER ERROR ALARM 10-10-18 4:30AM SYSTEM PAPER OUT ALARM 10-10-18 4:30AM h 3 OTHER FP3: BLEND3 DEGRD COLLECT WARN CLEAR 10-05-18 10:00AM h 3 OTHER FP3: BLEND3 DEGRD COLLECT WARN ALARM 10-04-18 10:02AM h 1 OTHER FP1: BLEND3 DEGRD COLLECT WARN CLEAR 10-04-18 10:00AM h 1 OTHER FP1: BLEND3 DEGRD COLLECT WARN ALARM 10-03-18 10:02AM SYSTEM PRINTER ERROR CLEAR 9-24-18 2:59PM SYSTEM PAPER OUT CLEAR 9-24-18 2:59PM SYSTEM PRINTER ERROR ALARM 9-24-18 2:59PM SYSTEM PAPER OUT ALARM 9-24-18 2:59PM h11 OTHER FP11: BLEND3 DEGRD COLLECT WARN CLEAR 9-24-18 10:00AM h11 OTHER FP11: BLEND3 DEGRD COLLECT WARN ALARM 9-23-18 10:01AM I20600 NOV 15, 2018 9:13 AM 286917 SPARKLING IMA 2301 H ST. BAKERSFIELD,CA 93301 661-324-8455 TANK ALARM HISTORY TANK 1 UNLEADED 87 OVERFILL ALARM NOV 13, 2018 12:56 AM NOV 6, 2018 11:25 PM OCT 14, 2018 10:29 AM LOW PRODUCT ALARM NOV 19, 2013 9:27 AM JUN 26, 2013 4:22 PM HIGH PRODUCT ALARM DEC 1, 2014 11:11 AM MAR 7, 2013 5:09 AM FEB 25, 2013 4:03 AM INVALID FUEL LEVEL NOV 19, 2015 9:08 AM NOV 19, 2013 9:27 AM PROBE OUT NOV 20, 2017 4:16 PM NOV 20, 2017 4:03 PM NOV 20, 2017 3:49 PM DELIVERY NEEDED NOV 20, 2017 3:49 PM JUL 20, 2017 8:00 PM AUG 6, 2015 9:47 AM LOW TEMP WARNING NOV 20, 2017 4:17 PM NOV 16, 2016 10:22 AM NOV 16, 2016 9:53 AM TANK 2 SUPREME 91 OVERFILL ALARM DEC 30, 2017 9:13 AM NOV 15, 2017 10:22 AM NOV 16, 2016 10:23 AM LOW PRODUCT ALARM NOV 16, 2016 9:50 AM INVALID FUEL LEVEL NOV 19, 2014 9:15 AM NOV 19, 2014 8:50 AM NOV 19, 2012 9:00 AM PROBE OUT NOV 20, 2017 4:17 PM NOV 20, 2017 4:02 PM NOV 15, 2017 10:22 AM DELIVERY NEEDED NOV 20, 2017 4:02 PM NOV 15, 2017 9:24 AM NOV 16, 2016 9:50 AM LOW TEMP WARNING NOV 20, 2017 4:18 PM NOV 16, 2016 10:25 AM NOV 16, 2016 9:51 AM TANK 3 DIESEL OVERFILL ALARM NOV 15, 2017 10:18 AM NOV 16, 2016 10:26 AM NOV 19, 2015 9:48 AM LOW PRODUCT ALARM NOV 19, 2015 9:05 AM HIGH PRODUCT ALARM NOV 15, 2017 10:18 AM INVALID FUEL LEVEL NOV 16, 2016 9:51 AM PROBE OUT NOV 15, 2017 10:19 AM NOV 15, 2017 9:26 AM NOV 16, 2016 10:27 AM DELIVERY NEEDED NOV 16, 2016 9:50 AM NOV 19, 2015 9:05 AM LOW TEMP WARNING NOV 19, 2015 9:50 AM NOV 19, 2014 9:18 AM NOV 19, 2013 10:08 AM I38200 NOV 15, 2018 9:13 AM I30200 NOV 15, 2018 9:13 AM 286917 SPARKLING IMA 2301 H ST. BAKERSFIELD,CA 93301 661-324-8455 LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 DISP. 1-2 NOV 15, 2017 10:47 AM SENSOR OUT ALARM NOV 15, 2017 10:30 AM FUEL ALARM NOV 16, 2016 10:35 AM SENSOR OUT ALARM 2 DISP. 3-4 NOV 15, 2017 10:48 AM SENSOR OUT ALARM NOV 15, 2017 10:31 AM FUEL ALARM NOV 16, 2016 10:35 AM SENSOR OUT ALARM 3 DISP. 11-12 NOV 15, 2017 10:48 AM SENSOR OUT ALARM NOV 15, 2017 10:34 AM FUEL ALARM NOV 16, 2016 10:35 AM SENSOR OUT ALARM 4 DISP. 7-8 NOV 15, 2017 10:48 AM SENSOR OUT ALARM NOV 15, 2017 10:33 AM FUEL ALARM NOV 16, 2016 10:35 AM SENSOR OUT ALARM 5 DISP. 9-10 NOV 15, 2017 10:47 AM SENSOR OUT ALARM NOV 15, 2017 10:34 AM FUEL ALARM MAY 24, 2017 9:16 AM FUEL ALARM 6 DISP 5-6 NOV 15, 2017 10:47 AM SENSOR OUT ALARM NOV 15, 2017 10:32 AM FUEL ALARM NOV 16, 2016 10:35 AM SENSOR OUT ALARM 7 DISP. 13-14 NOV 15, 2017 10:48 AM SENSOR OUT ALARM NOV 15, 2017 10:36 AM FUEL ALARM NOV 16, 2016 10:35 AM SENSOR OUT ALARM 8 DISP. 15-16 NOV 15, 2017 10:48 AM SENSOR OUT ALARM NOV 15, 2017 10:30 AM FUEL ALARM NOV 16, 2016 10:35 AM SENSOR OUT ALARM 9 UNLEADED SUMP NOV 15, 2017 10:47 AM SENSOR OUT ALARM NOV 15, 2017 10:28 AM FUEL ALARM NOV 16, 2016 10:35 AM SENSOR OUT ALARM 10 SUPREME SUMP NOV 15, 2017 10:47 AM SENSOR OUT ALARM NOV 15, 2017 10:28 AM FUEL ALARM MAR 28, 2017 2:43 PM SETUP DATA WARNING 11 DIESEL SUMP NOV 15, 2017 10:47 AM SENSOR OUT ALARM NOV 15, 2017 10:29 AM FUEL ALARM NOV 16, 2016 10:35 AM SENSOR OUT ALARM 12 UNLEADED ANNULAR SEP 12, 2018 6:16 PM FUEL ALARM SEP 12, 2018 12:24 PM FUEL ALARM SEP 2, 2018 3:34 AM FUEL ALARM 13 SUPREME ANNULAR NOV 15, 2017 10:47 AM FUEL ALARM NOV 15, 2017 10:05 AM FUEL ALARM MAR 28, 2017 2:38 PM FUEL ALARM 14 DIESEL ANNULAR NOV 15, 2017 10:47 AM FUEL ALARM NOV 15, 2017 9:48 AM FUEL ALARM NOV 16, 2016 10:11 AM FUEL ALARM I31600 NOV 15, 2018 9:13 AM 286917 SPARKLING IMA 2301 H ST. BAKERSFIELD,CA 93301 661-324-8455 SMART SENSOR ALARM HISTORY REPORT SENSOR LOCATION 1 FM 1-2 AUG 23, 2013 3:29 PM COMMUNICATION ALARM 2 FM 3-4 3 FM 5-6 4 FM 7-8 5 FM 9-10 MAY 19, 2014 10:48 PM COMMUNICATION ALARM 6 FM 11-12 7 FM 13-14 8 PRESSURE SENSOR NOV 16, 2016 10:36 AM COMMUNICATION ALARM JUL 23, 2010 8:06 AM COMMUNICATION ALARM 9 FM 15-16 I40200 NOV 15, 2018 9:13 AM I40300 NOV 15, 2018 9:13 AM I34200 NOV 15, 2018 9:13 AM I34700 NOV 15, 2018 9:13 AM IV0100 NOV 15, 2018 9:13 AM 286917 SPARKLING IMA 2301 H ST. BAKERSFIELD,CA 93301 661-324-8455 ISD ALARM STATUS REPORT EVR TYPE: VACUUM ASSIST ISD TYPE: 01.03 VAPOR PROCESSOR TYPE: NONE OVERALL STATUS :PASS EVR VAPOR COLLECTION :PASS EVR VAPOR CONTAINMENT :PASS ISD MONITOR UP-TIME :100% EVR/ISD PASS TIME :100% WARNING ALARMS DATE TIME DESCRIPTION READING VALUE 18-11-11 10:02:35 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.47 18-11-04 10:03:27 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 1.84 18-10-16 10:03:57 A/L RATIO DEGRADATION FP12 BLEND3 0.80 18-10-15 10:04:28 A/L RATIO DEGRADATION FP12 BLEND3 0.79 18-10-14 10:04:21 A/L RATIO DEGRADATION FP12 BLEND3 0.79 18-10-13 10:03:01 A/L RATIO DEGRADATION FP12 BLEND3 0.80 18-10-12 10:02:29 A/L RATIO DEGRADATION FP12 BLEND3 0.78 18-10-11 10:02:09 A/L RATIO DEGRADATION FP12 BLEND3 0.77 18-10-10 10:02:40 A/L RATIO DEGRADATION FP12 BLEND3 0.76 18-10-04 10:02:40 A/L RATIO DEGRADATION FP 3 BLEND3 0.80 FAILURE ALARMS DATE TIME DESCRIPTION READING VALUE 16-10-13 10:03:26 A/L RATIO GROSS BLOCKAGE FP 7 BLEND3 BLKD 15-04-02 10:01:23 A/L RATIO GROSS BLOCKAGE FP12 BLEND3 BLKD 11-08-16 10:03:25 A/L RATIO GROSS BLOCKAGE FP 6 BLEND3 BLKD 10-10-08 10:01:09 SETUP SELFTEST MISSING HOSE(S) 10-10-07 10:01:09 SETUP SELFTEST MISSING HOSE(S) 10-10-06 10:01:09 SETUP SELFTEST MISSING HOSE(S) 10-10-05 10:01:09 SETUP SELFTEST MISSING HOSE(S) 10-10-04 10:01:10 SETUP SELFTEST MISSING HOSE(S) 10-10-03 10:01:09 SETUP SELFTEST MISSING HOSE(S) 10-10-02 10:01:09 SETUP SELFTEST MISSING HOSE(S) SHUTDOWN & MISCELLANEOUS EVENTS DATE TIME DESCRIPTION ACTION/NAME 18-11-14 10:02:24 READINESS ISD:PP EVR:NP EVR READINESS PENDING 18-11-13 10:02:43 READINESS ISD:PP EVR:NP EVR READINESS PENDING 18-11-12 10:02:54 READINESS ISD:PP EVR:NP EVR READINESS PENDING 18-11-11 14:35:13 CONTAINMENT GROSS & DEGRD TEST MANUALLY CLEARED 18-11-11 10:02:35 READINESS ISD:PP EVR:NF CHECK EVR SYSTEM 18-11-10 10:03:26 READINESS ISD:PP EVR:NP EVR READINESS PENDING 18-11-09 10:03:13 READINESS ISD:PP EVR:NP EVR READINESS PENDING 18-11-08 10:02:59 READINESS ISD:PP EVR:NP EVR READINESS PENDING 18-11-07 10:04:23 READINESS ISD:PP EVR:NP EVR READINESS PENDING 18-11-06 10:03:44 READINESS ISD:PP EVR:NP EVR READINESS PENDING Sparkling chevron after history Responses Received: I10200 NOV 15, 2018 11:21 AM 286917 SPARKLING IMA 2301 H ST. BAKERSFIELD,CA 93301 661-324-8455 SYSTEM CONFIGURATION SLOT BOARD TYPE POWER ON RESET CURRENT 1 UNUSED 10020167 9818532 2 4 PROBE / G.T. 163726 163131 3 8SMARTSENSOR BD 39558 39477 4 7SMARTSENSOR BD 508286 506344 5 INTERSTITIAL BD 201774 201236 6 INTERSTITIAL BD 202243 201555 7 INTERSTITIAL BD 10002575 200416 8 UNUSED 9996797 9807597 9 RELAY BOARD 14986 14985 10 RELAY BOARD 14964 14941 11 UNUSED 10007979 9833421 12 UNUSED 9986521 9795518 13 UNUSED 9995371 9817958 14 UNUSED 9993588 9810959 15 UNUSED 9983600 9809210 16 UNUSED 10000096 9817980 COMM 1 ELEC DISP INT. 100682 100400 COMM 2 RS232 SERIAL BD 14964 14985 COMM 3 SERIAL SAT BD 9994383 479887 COMM 4 UNUSED 9993287 9814524 COMM 5 UNUSED 9990602 9814196 COMM 6 UNUSED 9984760 9794993 I90200 NOV 15, 2018 11:21 AM SOFTWARE REVISION LEVEL VERSION 330.01 SOFTWARE# 346330-100-B CREATED - 10.07.23.17.25 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS CSLD BIR FUEL MANAGER ISD PLLD 0.10 AUTO 0.20 REPETITIV WPLLD 0.10 AUTO 0.20 REPETITIV I11100 NOV 15, 2018 11:21 AM 286917 SPARKLING IMA 2301 H ST. BAKERSFIELD,CA 93301 661-324-8455 PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME L14 ANNULAR DIESEL ANNULAR FUEL ALARM CLEAR 11-15-18 10:27AM L12 ANNULAR UNLEADED ANNULAR FUEL ALARM CLEAR 11-15-18 10:27AM L11 STP SUMP DIESEL SUMP SENSOR OUT ALARM CLEAR 11-15-18 10:27AM L 4 DISP PAN DISP. 7-8 SENSOR OUT ALARM CLEAR 11-15-18 10:27AM L13 ANNULAR SUPREME ANNULAR FUEL ALARM CLEAR 11-15-18 10:27AM L10 STP SUMP SUPREME SUMP SENSOR OUT ALARM CLEAR 11-15-18 10:27AM L 3 DISP PAN DISP. 11-12 SENSOR OUT ALARM CLEAR 11-15-18 10:27AM L 9 STP SUMP UNLEADED SUMP SENSOR OUT ALARM CLEAR 11-15-18 10:27AM L 8 DISP PAN DISP. 15-16 SENSOR OUT ALARM CLEAR 11-15-18 10:27AM L 2 DISP PAN DISP. 3-4 SENSOR OUT ALARM CLEAR 11-15-18 10:27AM L 7 DISP PAN DISP. 13-14 SENSOR OUT ALARM CLEAR 11-15-18 10:27AM L 1 DISP PAN DISP. 1-2 SENSOR OUT ALARM CLEAR 11-15-18 10:27AM L 6 DISP PAN DISP 5-6 SENSOR OUT ALARM CLEAR 11-15-18 10:27AM L10 STP SUMP SUPREME SUMP SENSOR OUT ALARM ALARM 11-15-18 10:27AM L 5 DISP PAN DISP. 9-10 SENSOR OUT ALARM CLEAR 11-15-18 10:27AM L 9 STP SUMP UNLEADED SUMP SENSOR OUT ALARM ALARM 11-15-18 10:27AM L 8 DISP PAN DISP. 15-16 SENSOR OUT ALARM ALARM 11-15-18 10:27AM L 7 DISP PAN DISP. 13-14 SENSOR OUT ALARM ALARM 11-15-18 10:27AM L14 ANNULAR DIESEL ANNULAR FUEL ALARM ALARM 11-15-18 10:27AM L 6 DISP PAN DISP 5-6 SENSOR OUT ALARM ALARM 11-15-18 10:27AM L13 ANNULAR SUPREME ANNULAR FUEL ALARM ALARM 11-15-18 10:27AM L 5 DISP PAN DISP. 9-10 SENSOR OUT ALARM ALARM 11-15-18 10:27AM L12 ANNULAR UNLEADED ANNULAR FUEL ALARM ALARM 11-15-18 10:27AM L 4 DISP PAN DISP. 7-8 SENSOR OUT ALARM ALARM 11-15-18 10:27AM L 3 DISP PAN DISP. 11-12 SENSOR OUT ALARM ALARM 11-15-18 10:27AM L11 STP SUMP DIESEL SUMP SENSOR OUT ALARM ALARM 11-15-18 10:27AM L 2 DISP PAN DISP. 3-4 SENSOR OUT ALARM ALARM 11-15-18 10:27AM L 1 DISP PAN DISP. 1-2 SENSOR OUT ALARM ALARM 11-15-18 10:27AM T 1 TANK UNLEADED 87 PROBE OUT CLEAR 11-15-18 10:23AM T 1 TANK UNLEADED 87 PROBE OUT ALARM 11-15-18 10:22AM T 1 TANK UNLEADED 87 OVERFILL ALARM CLEAR 11-15-18 10:22AM T 1 TANK UNLEADED 87 OVERFILL ALARM ALARM 11-15-18 10:20AM T 2 TANK SUPREME 91 PROBE OUT CLEAR 11-15-18 10:18AM T 2 TANK SUPREME 91 PROBE OUT ALARM 11-15-18 10:18AM T 2 TANK SUPREME 91 OVERFILL ALARM CLEAR 11-15-18 10:18AM T 2 TANK SUPREME 91 OVERFILL ALARM ALARM 11-15-18 10:16AM T 3 TANK DIESEL PROBE OUT CLEAR 11-15-18 10:13AM T 3 TANK DIESEL PROBE OUT ALARM 11-15-18 10:12AM T 3 TANK DIESEL OVERFILL ALARM CLEAR 11-15-18 10:12AM L14 ANNULAR DIESEL ANNULAR FUEL ALARM CLEAR 11-15-18 10:12AM T 3 TANK DIESEL OVERFILL ALARM ALARM 11-15-18 10:10AM T 3 TANK DIESEL PROBE OUT CLEAR 11-15-18 10:10AM T 3 TANK DIESEL PROBE OUT ALARM 11-15-18 10:08AM L14 ANNULAR DIESEL ANNULAR FUEL ALARM ALARM 11-15-18 10:07AM L13 ANNULAR SUPREME ANNULAR FUEL ALARM CLEAR 11-15-18 10:06AM T 1 TANK UNLEADED 87 PROBE OUT CLEAR 11-15-18 10:03AM T 1 TANK UNLEADED 87 PROBE OUT ALARM 11-15-18 10:03AM T 2 TANK SUPREME 91 PROBE OUT CLEAR 11-15-18 10:01AM T 2 TANK SUPREME 91 PROBE OUT ALARM 11-15-18 10:00AM L13 ANNULAR SUPREME ANNULAR FUEL ALARM ALARM 11-15-18 9:59AM I11200 NOV 15, 2018 11:21 AM 286917 SPARKLING IMA 2301 H ST. BAKERSFIELD,CA 93301 661-324-8455 NON-PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME T 3 TANK DIESEL LOW TEMP WARNING CLEAR 11-15-18 10:13AM T 3 TANK DIESEL LOW TEMP WARNING ALARM 11-15-18 10:13AM T 3 TANK DIESEL HIGH PRODUCT ALARM CLEAR 11-15-18 10:12AM T 3 TANK DIESEL HIGH PRODUCT ALARM ALARM 11-15-18 10:10AM SYSTEM PRINTER ERROR CLEAR 11-13-18 2:30PM SYSTEM PAPER OUT CLEAR 11-13-18 2:30PM SYSTEM PRINTER ERROR ALARM 11-13-18 2:30PM SYSTEM PAPER OUT ALARM 11-13-18 2:30PM SYSTEM PRINTER ERROR CLEAR 11-13-18 2:30PM SYSTEM PAPER OUT CLEAR 11-13-18 2:30PM SYSTEM PRINTER ERROR ALARM 11-13-18 2:30PM SYSTEM PAPER OUT ALARM 11-13-18 2:30PM SYSTEM PRINTER ERROR CLEAR 11-13-18 2:30PM SYSTEM PAPER OUT CLEAR 11-13-18 2:30PM SYSTEM PRINTER ERROR ALARM 11-13-18 2:30PM SYSTEM PAPER OUT ALARM 11-13-18 2:30PM OTHER ISD GROSS PRES WARN CLEAR 11-11-18 2:35PM OTHER ISD GROSS PRES WARN ALARM 11-11-18 10:02AM SYSTEM PRINTER ERROR CLEAR 11-09-18 9:46AM SYSTEM PRINTER ERROR ALARM 11-09-18 9:46AM SYSTEM PRINTER ERROR CLEAR 11-08-18 3:43PM SYSTEM PAPER OUT CLEAR 11-08-18 3:43PM SYSTEM PRINTER ERROR ALARM 11-08-18 3:42PM SYSTEM PAPER OUT ALARM 11-08-18 3:42PM SYSTEM PRINTER ERROR CLEAR 11-07-18 7:26AM SYSTEM PAPER OUT CLEAR 11-07-18 7:26AM SYSTEM PRINTER ERROR ALARM 11-07-18 7:25AM SYSTEM PAPER OUT ALARM 11-07-18 7:25AM SYSTEM PRINTER ERROR CLEAR 11-07-18 7:25AM SYSTEM PAPER OUT CLEAR 11-07-18 7:25AM SYSTEM PRINTER ERROR ALARM 11-07-18 7:24AM SYSTEM PAPER OUT ALARM 11-07-18 7:24AM OTHER ISD GROSS PRES WARN CLEAR 11-04-18 10:18AM OTHER ISD GROSS PRES WARN ALARM 11-04-18 10:03AM SYSTEM PRINTER ERROR CLEAR 10-22-18 12:29PM SYSTEM PAPER OUT CLEAR 10-22-18 12:29PM SYSTEM PAPER OUT ALARM 10-22-18 12:29PM SYSTEM PRINTER ERROR ALARM 10-22-18 12:29PM h12 OTHER FP12: BLEND3 DEGRD COLLECT WARN CLEAR 10-16-18 12:15PM h12 OTHER FP12: BLEND3 DEGRD COLLECT WARN ALARM 10-10-18 10:02AM SYSTEM PRINTER ERROR CLEAR 10-10-18 4:30AM SYSTEM PAPER OUT CLEAR 10-10-18 4:30AM SYSTEM PRINTER ERROR ALARM 10-10-18 4:30AM SYSTEM PAPER OUT ALARM 10-10-18 4:30AM h 3 OTHER FP3: BLEND3 DEGRD COLLECT WARN CLEAR 10-05-18 10:00AM h 3 OTHER FP3: BLEND3 DEGRD COLLECT WARN ALARM 10-04-18 10:02AM h 1 OTHER FP1: BLEND3 DEGRD COLLECT WARN CLEAR 10-04-18 10:00AM h 1 OTHER FP1: BLEND3 DEGRD COLLECT WARN ALARM 10-03-18 10:02AM SYSTEM PRINTER ERROR CLEAR 9-24-18 2:59PM SYSTEM PAPER OUT CLEAR 9-24-18 2:59PM I20600 NOV 15, 2018 11:21 AM 286917 SPARKLING IMA 2301 H ST. BAKERSFIELD,CA 93301 661-324-8455 TANK ALARM HISTORY TANK 1 UNLEADED 87 OVERFILL ALARM NOV 15, 2018 10:20 AM NOV 13, 2018 12:56 AM NOV 6, 2018 11:25 PM LOW PRODUCT ALARM NOV 19, 2013 9:27 AM JUN 26, 2013 4:22 PM HIGH PRODUCT ALARM DEC 1, 2014 11:11 AM MAR 7, 2013 5:09 AM FEB 25, 2013 4:03 AM INVALID FUEL LEVEL NOV 19, 2015 9:08 AM NOV 19, 2013 9:27 AM PROBE OUT NOV 15, 2018 10:22 AM NOV 15, 2018 10:03 AM NOV 20, 2017 4:16 PM DELIVERY NEEDED NOV 20, 2017 3:49 PM JUL 20, 2017 8:00 PM AUG 6, 2015 9:47 AM LOW TEMP WARNING NOV 20, 2017 4:17 PM NOV 16, 2016 10:22 AM NOV 16, 2016 9:53 AM TANK 2 SUPREME 91 OVERFILL ALARM NOV 15, 2018 10:16 AM DEC 30, 2017 9:13 AM NOV 15, 2017 10:22 AM LOW PRODUCT ALARM NOV 16, 2016 9:50 AM INVALID FUEL LEVEL NOV 19, 2014 9:15 AM NOV 19, 2014 8:50 AM NOV 19, 2012 9:00 AM PROBE OUT NOV 15, 2018 10:18 AM NOV 15, 2018 10:00 AM NOV 20, 2017 4:17 PM DELIVERY NEEDED NOV 20, 2017 4:02 PM NOV 15, 2017 9:24 AM NOV 16, 2016 9:50 AM LOW TEMP WARNING NOV 20, 2017 4:18 PM NOV 16, 2016 10:25 AM NOV 16, 2016 9:51 AM TANK 3 DIESEL OVERFILL ALARM NOV 15, 2018 10:10 AM NOV 15, 2017 10:18 AM NOV 16, 2016 10:26 AM LOW PRODUCT ALARM NOV 19, 2015 9:05 AM HIGH PRODUCT ALARM NOV 15, 2018 10:10 AM NOV 15, 2017 10:18 AM INVALID FUEL LEVEL NOV 16, 2016 9:51 AM PROBE OUT NOV 15, 2018 10:12 AM NOV 15, 2018 10:08 AM NOV 15, 2017 10:19 AM DELIVERY NEEDED NOV 16, 2016 9:50 AM NOV 19, 2015 9:05 AM LOW TEMP WARNING NOV 15, 2018 10:13 AM NOV 19, 2015 9:50 AM NOV 19, 2014 9:18 AM I38200 NOV 15, 2018 11:21 AM I30200 NOV 15, 2018 11:21 AM 286917 SPARKLING IMA 2301 H ST. BAKERSFIELD,CA 93301 661-324-8455 LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 DISP. 1-2 NOV 15, 2018 10:27 AM SENSOR OUT ALARM NOV 15, 2018 9:52 AM FUEL ALARM NOV 15, 2017 10:47 AM SENSOR OUT ALARM 2 DISP. 3-4 NOV 15, 2018 10:27 AM SENSOR OUT ALARM NOV 15, 2018 9:51 AM FUEL ALARM NOV 15, 2017 10:48 AM SENSOR OUT ALARM 3 DISP. 11-12 NOV 15, 2018 10:27 AM SENSOR OUT ALARM NOV 15, 2018 9:47 AM FUEL ALARM NOV 15, 2017 10:48 AM SENSOR OUT ALARM 4 DISP. 7-8 NOV 15, 2018 10:27 AM SENSOR OUT ALARM NOV 15, 2018 9:49 AM FUEL ALARM NOV 15, 2017 10:48 AM SENSOR OUT ALARM 5 DISP. 9-10 NOV 15, 2018 10:27 AM SENSOR OUT ALARM NOV 15, 2018 9:48 AM FUEL ALARM NOV 15, 2017 10:47 AM SENSOR OUT ALARM 6 DISP 5-6 NOV 15, 2018 10:27 AM SENSOR OUT ALARM NOV 15, 2018 9:50 AM FUEL ALARM NOV 15, 2017 10:47 AM SENSOR OUT ALARM 7 DISP. 13-14 NOV 15, 2018 10:27 AM SENSOR OUT ALARM NOV 15, 2018 9:47 AM FUEL ALARM NOV 15, 2017 10:48 AM SENSOR OUT ALARM 8 DISP. 15-16 NOV 15, 2018 10:27 AM SENSOR OUT ALARM NOV 15, 2018 9:46 AM FUEL ALARM NOV 15, 2017 10:48 AM SENSOR OUT ALARM 9 UNLEADED SUMP NOV 15, 2018 10:27 AM SENSOR OUT ALARM NOV 15, 2018 9:41 AM FUEL ALARM NOV 15, 2017 10:47 AM SENSOR OUT ALARM 10 SUPREME SUMP NOV 15, 2018 10:27 AM SENSOR OUT ALARM NOV 15, 2018 9:40 AM FUEL ALARM NOV 15, 2017 10:47 AM SENSOR OUT ALARM 11 DIESEL SUMP NOV 15, 2018 10:27 AM SENSOR OUT ALARM NOV 15, 2018 9:39 AM FUEL ALARM NOV 15, 2017 10:47 AM SENSOR OUT ALARM 12 UNLEADED ANNULAR NOV 15, 2018 10:27 AM FUEL ALARM SEP 12, 2018 6:16 PM FUEL ALARM SEP 12, 2018 12:24 PM FUEL ALARM 13 SUPREME ANNULAR NOV 15, 2018 10:27 AM FUEL ALARM NOV 15, 2018 9:59 AM FUEL ALARM NOV 15, 2017 10:47 AM FUEL ALARM 14 DIESEL ANNULAR NOV 15, 2018 10:27 AM FUEL ALARM NOV 15, 2018 10:07 AM FUEL ALARM NOV 15, 2017 10:47 AM FUEL ALARM I31600 NOV 15, 2018 11:22 AM 286917 SPARKLING IMA 2301 H ST. BAKERSFIELD,CA 93301 661-324-8455 SMART SENSOR ALARM HISTORY REPORT SENSOR LOCATION 1 FM 1-2 AUG 23, 2013 3:29 PM COMMUNICATION ALARM 2 FM 3-4 3 FM 5-6 4 FM 7-8 5 FM 9-10 MAY 19, 2014 10:48 PM COMMUNICATION ALARM 6 FM 11-12 7 FM 13-14 8 PRESSURE SENSOR NOV 16, 2016 10:36 AM COMMUNICATION ALARM JUL 23, 2010 8:06 AM COMMUNICATION ALARM 9 FM 15-16 I40200 NOV 15, 2018 11:22 AM I40300 NOV 15, 2018 11:22 AM I34200 NOV 15, 2018 11:22 AM I34700 NOV 15, 2018 11:22 AM IV0100 NOV 15, 2018 11:22 AM 286917 SPARKLING IMA 2301 H ST. BAKERSFIELD,CA 93301 661-324-8455 ISD ALARM STATUS REPORT EVR TYPE: VACUUM ASSIST ISD TYPE: 01.03 VAPOR PROCESSOR TYPE: NONE OVERALL STATUS :PASS EVR VAPOR COLLECTION :PASS EVR VAPOR CONTAINMENT :PASS ISD MONITOR UP-TIME :100% EVR/ISD PASS TIME :100% WARNING ALARMS DATE TIME DESCRIPTION READING VALUE 18-11-11 10:02:35 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.47 18-11-04 10:03:27 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 1.84 18-10-16 10:03:57 A/L RATIO DEGRADATION FP12 BLEND3 0.80 18-10-15 10:04:28 A/L RATIO DEGRADATION FP12 BLEND3 0.79 18-10-14 10:04:21 A/L RATIO DEGRADATION FP12 BLEND3 0.79 18-10-13 10:03:01 A/L RATIO DEGRADATION FP12 BLEND3 0.80 18-10-12 10:02:29 A/L RATIO DEGRADATION FP12 BLEND3 0.78 18-10-11 10:02:09 A/L RATIO DEGRADATION FP12 BLEND3 0.77 18-10-10 10:02:40 A/L RATIO DEGRADATION FP12 BLEND3 0.76 18-10-04 10:02:40 A/L RATIO DEGRADATION FP 3 BLEND3 0.80 FAILURE ALARMS DATE TIME DESCRIPTION READING VALUE 16-10-13 10:03:26 A/L RATIO GROSS BLOCKAGE FP 7 BLEND3 BLKD 15-04-02 10:01:23 A/L RATIO GROSS BLOCKAGE FP12 BLEND3 BLKD 11-08-16 10:03:25 A/L RATIO GROSS BLOCKAGE FP 6 BLEND3 BLKD 10-10-08 10:01:09 SETUP SELFTEST MISSING HOSE(S) 10-10-07 10:01:09 SETUP SELFTEST MISSING HOSE(S) 10-10-06 10:01:09 SETUP SELFTEST MISSING HOSE(S) 10-10-05 10:01:09 SETUP SELFTEST MISSING HOSE(S) 10-10-04 10:01:10 SETUP SELFTEST MISSING HOSE(S) 10-10-03 10:01:09 SETUP SELFTEST MISSING HOSE(S) 10-10-02 10:01:09 SETUP SELFTEST MISSING HOSE(S) SHUTDOWN & MISCELLANEOUS EVENTS DATE TIME DESCRIPTION ACTION/NAME 18-11-15 10:28:16 READINESS ISD:PP EVR:NN EVR READINESS PENDING 18-11-15 10:28:16 ISD STARTUP 18-11-15 10:28:05 ISD SHUTDOWN 18-11-15 10:02:43 READINESS ISD:PP EVR:NP EVR READINESS PENDING 18-11-14 10:02:24 READINESS ISD:PP EVR:NP EVR READINESS PENDING 18-11-13 10:02:43 READINESS ISD:PP EVR:NP EVR READINESS PENDING 18-11-12 10:02:54 READINESS ISD:PP EVR:NP EVR READINESS PENDING 18-11-11 14:35:13 CONTAINMENT GROSS & DEGRD TEST MANUALLY CLEARED 18-11-11 10:02:35 READINESS ISD:PP EVR:NF CHECK EVR SYSTEM 18-11-10 10:03:26 READINESS ISD:PP EVR:NP EVR READINESS PENDING &(56 &DOLIRUQLD(QYLURQPHQWDO5HSRUWLQJ6\VWHP,' ,GHQWLILFDWLRQ867 8QGHUJURXQG6WRUDJH7DQN,&& ,QWHUQDWLRQDO&RGH&RXQFLO 81 ZZZXQLGRFVRUJ5HY 81'(5*5281'6725$*(7$1. 63,//&217$,1(57(67,1*5(3257)250 3DJHRI  7\SHRI$FWLRQ,QVWDOODWLRQ7HVW5HSDLU7HVW0RQWK7HVW , )$&,/,7<,1)250$7,21 &(56,''DWHRI6SLOO&RQWDLQHU7HVW %XVLQHVV1DPH(Same as Facility Name or DBA-Doing Business As) %XVLQHVV6LWH$GGUHVV &LW\ =,3&RGH ,, 81'(5*5281'6725$*(7$1.6(59,&(7(&+1,&,$1,1)250$7,21 1DPHRI8676HUYLFH7HFKQLFLDQ3HUIRUPLQJWKH7HVW(Print as shown on the ICC Certification.) 3KRQH &RQWUDFWRU7DQN7HVWHU/LFHQVH ,&&&HUWLILFDWLRQ ,&&&HUWLILFDWLRQ([SLUDWLRQ'DWH 6SLOO&RQWDLQHU7HVWLQJ7UDLQLQJDQG&HUWLILFDWLRQV(List applicable certifications.) ,,, 63,//&217$,1(57(67,1*,1)250$7,21 7HVW0HWKRG8VHG0DQXIDFWXUHU*XLGHOLQHV(Specify) ,QGXVWU\&RGHRU(QJLQHHULQJ6WDQGDUG (Specify) (QJLQHHUHG0HWKRG(Specify) Attach the testing procedures and all documentation required to determine the results.RI$WWDFKHG3DJHV 7$1.,'(By tank number, stored product, etc.) 6SLOO&RQWDLQHU0DQXIDFWXUHU 0HWKRGRI&DWKRGLF3URWHFWLRQ1RQ0HWDOOLF1RQ0HWDOOLF1RQ0HWDOOLF1RQ0HWDOOLF ,VRODWLRQ,VRODWLRQ,VRODWLRQ,VRODWLRQ 2WKHU(Specify in V.)2WKHU(Specify in V.)2WKHU(Specify in V.)2WKHU(Specify in V.) ,QVLGH'LDPHWHURI6SLOO&RQWDLQHU(Inches) 'HSWKRI6SLOO&RQWDLQHU(Inches) 'RHVWKHVSLOOFRQWDLQHUKDYHDJDOORQFDSDFLW\"<HV1R<HV1R<HV1R<HV1R 0HWKRGWR.HHS6SLOO&RQWDLQHU(PSW\'UDLQ9DOYH'UDLQ9DOYH'UDLQ9DOYH'UDLQ9DOYH 2QVLWH3XPS2QVLWH3XPS2QVLWH3XPS2QVLWH3XPS 2WKHU(Specify in V.)2WKHU(Specify in V.)2WKHU(Specify in V.)2WKHU(Specify in V.) ,9 6800$5<2)7(67,1*5(68/76 6SLOO&RQWDLQHU7HVW5HVXOWV3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLO 9 &200(176 Any items marked “Fail” above must be explained in this section. Any additional comments may also be provided here. 9, &(57,),&$7,21%<8676(59,&(7(&+1,&,$1&21'8&7,1*7+,67(67,1* ,KHUHE\FHUWLI\WKDWWKHVSLOOFRQWDLQHUVZHUHWHVWHGLQDFFRUGDQFHZLWK&DOLIRUQLD&RGHRI5HJXODWLRQV7LWOH'LYLVLRQ &KDSWHU6HFWLRQDQGDOOWKHLQIRUPDWLRQFRQWDLQHGKHUHLQLVDFFXUDWH 8676HUYLFH7HFKQLFLDQ6LJQDWXUH If the facility has more components than this form accommodates, additional copies of this page may be attached. Bakersfield 93301 804904 8374998 11/14/2019 Franklin fueling 1008973709 PEI 1200 1 87 Phil-tite 12.00” 18.00” 91 Phil-tite 12.00” 18.00” Diesel Phil-tite 12.00” 18.00” Frank Amestoy (800) 339-9930 10123120 11/15/2018 Sparkling Image Car Wash 2301 H Street SWRCB, January 2006 Spill Bucket Testing Report Form This form is intended for use by contractors performing annual testing of UST spill containment structures. The completed form and printouts from tests (if applicable), should be provided to the facility owner/operator for submittal to the local regulatory agency. 1. FACILITY INFORMATION Facility Name: Date of Testing: Facility Address: Facility Contact: Phone: Date Local Agency Was Notified of Testing : Name of Local Agency Inspector (if present during testing): 2. TESTING CONTRACTOR INFORMATION Company Name: Technician Conducting Test: Credentials1: CSLB Contractor ICC Service Tech. SWRCB Tank Tester Other (Specify) __________________ License Number(s): 3. SPILL BUCKET TESTING INFORMATION Test Method Used: Hydrostatic Vacuum Other Test Equipment Used: Equipment Resolution: Identify Spill Bucket (By Tank Number, Stored Product, etc.) 1234 Bucket Installation Type: Direct Bury Contained in Sump Direct Bury Contained in Sump Direct Bury Contained in Sump Direct Bury Contained in Sump Bucket Diameter: Bucket Depth: Wait time between applying vacuum/water and start of test: Test Start Time (TI): Initial Reading (RI): Test End Time (TF): Final Reading (RF): Test Duration (TF –TI): Change in Reading (RF -RI): Pass/Fail Threshold or Criteria: Test Result: Pass Fail Pass Fail Pass Fail Pass Fail Comments –(include information on repairs made prior to testing, and recommended follow-up for failed tests) CERTIFICATION OF TECHNICIAN RESPONSIBLE FOR CONDUCTING THIS TESTING I hereby certify that all the information contained in this report is true, accurate, and in full compliance with legal requirements. Technician’s Signature:________________________________________________ Date:_________________________ 1 State laws and regulations do not currently require testing to be performed by a qualified contractor. However, local requirements may be more stringent. Sparkling Image Car Wash 11/15/2018 2301 H Street Bakersfield 93301 Soo Ann (470) 650-1177 10/18/2018 Kris Karns Confidence UST Services, Inc. Frank Amestoy 804904 8374998 Lake test 0.0625” 87 91 Diesel 12.00” 12.00” 12.00” 18.00” 18.00” 18.00” 30 minutes 30 minutes 30 minutes 9:30am 9:30am 9:30am 17.00” 17.00” 17.00” 10:30am 10:30am 10:30am 17.00” 17.00” 17.00” 60 minutes 60 minutes 60 minutes 0.00” 0.00” 0.00” 0.0625” 0.0625” 0.0625” 11/15/2018 ✔✔ ✔ ✔✔✔ ✔✔✔