Loading...
HomeMy WebLinkAboutFMC 201925971 Towne Centre Drive, Foothill Ranch, CA 92610 Tel: (949) 460-5200 Fax: (949) 460-5210 Date: To: From: Sent Via: Re: 11/27/2019 Kris Karns Bakersfield City CUPA 1500 Truxtun Ave Bakersfield, CA 93301 Zac Kavanaugh Email Monitor Cert/Annual lnsp Foods Co# 384 2501 Haley St. Bakersfield, CA 93305 TRANSMITTAL The following test report(s) are included: Monitor Certification Comments: Please do not hesitate to call me at (949) 460-5200 if you have any questions or concerns regarding this work. Zac Kavanaugh Project Coordinator 2126152 Appendix VI UNDERGROUND STORAGE TANK MONITORING SYSTEM CERTIFICATION FORM /Pam~ 1 of6l This form must be used to document testing and servicing of underground storage tank {UST) monitoring eguigment. A COQll: of this form must be Qrovided to the UST owner or 012erator. The owner or OQerator must submit a COQll: of this form to the local agencll: regulating the USTs within 30 dall:S of the date of the monitoring SJl:stem certification. I. FACILITY INFORMATION CERSID I pate of Monitorinq Svstem Certification 10123132 11/19/2019 Business Name (Same as Facilil'L. Name or OBA -Doing Business As.! I Building# Foods Co# 384 Business Site Address I Qi1y I ZIP Code 2501 Haley St. Bakersfield 93305 II. UNDERGROUND STORAGE TANK SERVICE TECHNICIAN INFORMATION Name of Comganll: Performing the Certification I Phone# Belshire Environmental Services, Inc. (949) 460-5200 Mailing Address 25971 Towne Centre Dr., Foothill Ranch, CA 92610 Name of UST Service Technician Performing the Certification {.Print as shown on the ICC Cettification.) David Walker Contractorrrank Tester License# I ICC Certification# I ICC Certification ExQiration Date 808313 8854235 12/10/2020 Monitorina Svstem Trainina and Certifications /List all a11nficab/e cerlifications. l Exoiration Date See Attached m. RESULTS OF TESTING/SERVICING Indicate and attach the following_ ree.orts if the monitoring_ eg_uie.ment is cae.able of generating_ either. y M NA 0 Monitoring Sll:slem Set-uQ IV] Alarm Histoty ReQorl Was anll: monitoring eguiQment reQlaced? 0 D D (Jf "Yes," identifi. the sg_ecific devices reQ.laced and list the manufacturer and model for all re12Jacement 12.arts in section IV below.) Was damage. debris, or liguid found inside anll: seconda[Y containment Sll:Stems? • 0 D (If "Yes," cfescribe what was found in section IV below.) Is all monitoring eguiQment ogerational Qer manufacturer's sgecifications? 0 D D (If "No,'' describe Whl:'.'. in section IV below.) IV. COMMENTS If directed to use this section, describe how and when the issues were or will be corrected, Replaced 91 drain valve V. CERTIFICATION BY UST SERVICE TECHNICIAN CONDUCTING THIS TESTING I hereby certify that the egui~ment identified in this document was insf;!ected/serviced in accordance with California Code of Regulations, title 23, division 3, cha12ter 16, section 2638 and all information contained herein is true and accurate. Attached to this certification is information (e.g., manufacturers' checklists, monitoring system set•UQ, alarm history re1;1ort, etc.} necessary to verifv that this information and the site olan showina the lavout of UST svstem is complete and accurate. UST Service Technician Signature ~r_\) "'--J ,,J}\__ ____ UNDERGROUND STORAGE TANK MONITORING SYSTEM CERTIFICATION FORM 1Paae2of6\ VI. INVENTORY OF EQUIPMENT CERTIFIED A se12arate Monitoring_ S)lstem Certification Form must be e.ree.ared for each monitoring sj!stem control eanel. Make of Monitoring S~stem Control Panel I Model of Monitoring Sl£stem Control Panel II Software Version Installed Veeder-Root TLS-350 330.01 ------•,tt --··:--.. Monitorina Device Used Device Model # Monitorina Device Used Device Model # Tank ID: T1-87 Tank ID: T2-91 {Bv tank number stored vroduct etc. J /Bv tank number stored oroduct etc.) M ln-tank Gauging (SW Tank) Mag Plus ~ In-tank Gauging (SW Tank) Mag Plus ~ Annular SQace or Vault Sensor 794380-303 M Annular SQace or Vault Sensor 794380-303 0VPH Sensor nvPH Sensor Product Pioina Product Pioina D Mechanical LLD D Mechanical LLD @ Electronic LLD PLLD -Veeder-Ro @ Electronic LLD PLLD -Veeder-Ro M VPH Sensor (PiQing} VR001 M VPH Sensor (Piging) VR001 M SumQ Sensor 794380-323 M Sum12 Sensor 794380-323 M VPH Sensor (SumQ) 794380-304 M VPH Sensor (Sum12) 794380-304 Fill Pinina Fill Piolno n VPH Sensor (PiQing) n VPH Sensor (PiQing) ~ SumQ Sensor 794380-323 ~ SumQ Sensor 794380-323 M VPH Sensor (SumQ) 794380-304 M VPH Sensor (SumQ) 794380-304 Vent PiQing Vent PiQing M VPH Sensor (PiQing} VR001 M VPH Sensor (Piging) VR001 n SumQ Sensor n SumQ Sensor n VPH Sensor (SumQ) n VPH Sensor (Sum12) Vai;ior Recoverl£ Pi12ing Va12or Recove(Y PiQing MVPH Sensor (Piging) VR001 n VPH Sensor (PiQing) n SumQ Sensor D SumQ Sensor D VPH Sensor (Sum12} D VPH Sensor (SumQ) lc::B d 1 .... r1,,, #. J~ Tank ID: T3-DSL Tank ID: fBv tank number stored oroduct etc.l (Bv tank number stored oroduct etc.) M In-tank Gauging (SW Tank) Mag Plus n In-tank Gauging (SW Tank) ~ Annular SQace or Vault Sensor 794380-303 D Annular S12ace or Vault Sensor OVPH Sensor nvPH Sensor Product Ph:iina Product Pioino D Mechanical LLD D Mechanical LLD ~ Electronic LLD PLLD • Veeder-Ro D Electronic LLD ~ VPH Sensor (PiQing) VR001 D VPH Sensor (PiQing) ~ Sumr2 Sensor 794380-323 n Sum12 Sensor M VPH Sensor (Sum12l 794380-304 n VPH Sensor (SumQ) Fill PiPina Fill PiPina n VPH Sensor (Piill!l9J n VPH Sensor (PiQing) ~ SumQ Sensor 794380-323 n SumQ Sensor ~ VPH Sensor (Sum12} 794380-304 n VPH Sensor (SumQ) Vent Pioina Vent Pinina M VPH Sensor (PiQing) VR001 n VPH Sensor (PiQing) n SumQ Sensor n SumQ Sensor n VPH Sensor (SumQ) n VPH Sensor (Sumr2l Vaoor Recoverv Ph:iina Vaoor Recoverv Pioina n VPH Sensor (PiQing) n VPH Sensor (PiQing) n SumQ Sensor n Sumg Sensor n VPH Sensor (Sum12} n VPH Sensor (SumQ) Monitoring Device Used UDC ID; ~ Electronic Sensor ~ Mechanical Device ~ VPH Sensor Ironic Sensor hanical Device Sensor ~ Electronic Sensor ~ Mechanical Device ~VPH Sensor UOCID: D Electronic Sensor D Mechanical Device UNDERGROUND STORAGE TANK MONITORING SYSTEM CERTIFICATION FORM (Page 3of6) Device Model # 1/2 794380-323 Shear Valve -794380-304 5/6 794380-323 Shear Valve 794380-304 9/10 794380-323 Shear Valve 794380-304 13/14 794380-323 Shear Valve 794380-304 Vent Box Monitoring Device Used UDC 10: 3/4 ~ Electronic Sensor 794380-323 ~ Mechanical Device Shear Valve ~VPH Sensor 794380-304 UDCID: 7/8 ~ Electronic Sensor 794380-323 @ Mechanical Device Shear Valve @VPH Sensor 794380-304 UDC ID: 11/12 ~ Electronic Sensor 794380-323 ~ Mechanical Device Shear Valve ~VPH Sensor 794380-304 UDCIO: D Electronic Sensor Sump Sensor D VPH Sensor Device Model # Include information for every underground storage tank component monitored by this monitoring system control panel. If the monitoring system control panel monitors more components than this form accommodates, additional copies of these pages may be attached. VII. COMMENTS Use this section to provide any additional comments abou/ the inventory of /he equipment certified. UNDERGROUND STORAGE TANK MONITORING SYSTEM CERTIFICATION FORM /Paae 4 of 6l vm. MONITORING SYSTEM AND PROGRAMMING This section must be comgJeted if a monitoring l}_anel is used to ll_erlorm teak detection monitoring, y N NA Are the visual and audible alarms 012erational? 0 • • Were all sensors visually insi:1ected for kinks and breaks in the cables and for residual builduQ to ensure that floats move freely, 0 • D functionallv tested and confirmed ooerational? Were all sensors installed at lowest i:1oint of secondary containment and 12ositioned so that other eguiQment will not interfere with their 0 • • orooer ooeration? Was monitoring system sel-uQ reviewed to ensure QroQer settings? 0 • D Was the monitoring i:1anel's backuQ battery visually ins1:1ected, functionally tested, and confirmed oQerational? 0 • • Does the flow of fuel stoQ at the disi:1enser if a leak is detected in the under-disi:1enser containment? 0 D D Does the turbine automatically shut down if the QiQing secondary containment monitoring system fails to OQerate or is electrically 0 • • disconnected? Does the turbine automatically shut down if the QiQing secondai:y containment monitoring system detects a leak? 0 D D Which sensors initiate Qositive shut down? (Check all that a12Ql'i_.) MSumi:1 M Under-disQenser containment If alarms are relayed to a remote monitoring station, is all communications eguiQment (e.g. modem) oQerational? • • 0 For anv answer of "N" above describe in section IX how and when these deficiencies were or will be corrected. IX. COMMENTS X. IN-TANK GAUGING TESTING IV'I Check this box if tank oauoino is used onlv for inventorv control. fDo not comnlete this section.) n Check this box if NO tank gauging eguiQment is installed. (Do not com9/ete this section.) X M NA This section must be comoleted if in-tank aauaina is used to oerform leak detection monitorina, Has all in12ut wiring been ins12ected for kinks and breaks in the cables and for i:1roi:1er enti:y and termination, including testing for ground D D D faults? Were all in-tank gauging Qrobes visually ins12ected for damage and residue builduQ to ensure that floats move freel~, functional!~ tested, • • • and confirmed ooerational? Was accurac~ of s~stem's Qroduct level readings tested? • D • Was accuracy of s~stem's water level readings tested? • D • Were all Qrobes reinstalled QrOQerly? • D D Were all items on the eguiQment manufacturer's maintenance checklist comi:1leted? D D D For anv answer of "N" above describe in section XI how and when these deficiencies were or will be corrected. XI. COMMENTS UNDERGROUND STORAGE TANK MONITORING SYSTEM CERTIFICATION FORM rPaae s of 6l XII. LINE LEAK DETECTOR TESTING n Check this box if line leak detectors (LLD) are NOT installed. (Po not comQlete this section.) X M NA This section must be comvleted if LLDs are installed. Was a leak simulated to verify LLD Qerformance? 0 • • (Check all that ann/v.) Simulated leak rate verified: ~ 3GPH n 0.1 GPH no.2 GPH Was the testing aQQaratus QroQerly calibrated? 0 • • For emergency generator tank systems, does the LLD create an audible and visual alarm when a leak is detected? • • ~ For mechanical LLDs, does the LLD restrict the flow through the QiQe when a leak is detected? • • ~ For electronic LLDs, does the turbine automatically shut off when a leak is detected? 0 • • For electronic LLDs, does the turbine automatically shut off if any Qortion of the monitoring system is disabled or disconnected? 0 • • For electronic LLDs, does the turbine automatically shut off if any QOrtion of the monitoring system malfunctions or fails a test? 0 • • For electronic LLDs, have all accessible wiring connections been visually ins12ected for kinks and breaks? 0 • • Were all items on the eguiQment manufacturer's maintenance checklist comQleted? ~ • • Were all LLDs confirmed OQerational within regulalO!Y reguirements? ~ • • For anv answer of "N" above describe in section XIII how and when these issues were or will be corrected. XIII. COMMENTS XIV. VACUUM/ PRESSURE/ HYDROSTATIC MONITORING EQUIPMENT TESTING • Check this box if VPH monitoring is NOT used. (Do not comQlete this section.) This section must be come.feted if VPH monitoring_ is used to £2,erform leak detection monitoring_. System TyQe (Mark all that aQQI~.) M Vacuum n Pressure D Hydrostatic Sensor Functionality Interstitial Communication Sensor ID ComQonent(s) Monitored by this Sensor Test Test S-9 87 Prod ~Pass •.Bill MPass D..Eill1 S-10 87-91 Vapor MPass D£ill! MPass D..Eill1 S-11 87 Vent Chase MPass [IDjJ M Pass D..Eill1 S-12 91 Prod MPass [IDjJ M Pass D..Eill1 S-13 91 Vent ~Pass •.Bill ~Pass D..Eill1 S-14 Diesel Prod MPass •.Bill MPass D..Eill1 S-17 Diesel Vent Chase MPass •.Bill MPass D..Eill1 •Pass [IDjJ •Pass D..Eill1 •Pass [IDjJ •Pass •Fail ~ •Fail ~ Ohl! •Pass D£ill! ~ Ohl! ~ [IDjJ •Pass D..Eill1 How was interstitial communication verified? M Simulated leak at far ends of the interstitial SQace. n Visual lnsQection n Other (Desctibe the method in section XV below.) nGauge Was the vacuum or Qressure restored to OQerating levels in all interstitial sQaces? ~Yes n No (Describe the reason in sec/ion XV below.) For anv answer of "FAIL" above describe in section XV how and when these issues were or will be corrected. xv. COMMENTS UNDERGROUND STORAGE TANK SPILL CONTAINER TESTING REPORT FORM (Page 1 of 1) Type of Action D Installation Test D Repair Test ~ 12 Month Test I. FACILITY INFORMATION CERSID Date of Spill Container Test 10123132 11/19/2019 Business Name (Same as Facility Name or OBA-Doing Business As) Foods Co # 384 Business Site Address I City I ZIP Code 2501 Haley St. Bakersfield CA II. UNDERGROUND STORAGE TANK SERVICE TECHNICIAN INFORMATION Name of UST Service Technician Performing the Test (Print as shown on t/Je ICC Cer/ifica/ion.) I Phone# David Walker Contractor I Tank Tester License# 11cc Certification # ICC Certification Expiration Date 808313 8854235 12/10/2020 Spill Container Testing Training and CerlificalioM (List applicable certifications.) See Attached Ill. SPILL CONTAINER TESTING INFORMATION Test Method Used: D Manufacturer Guidelines (Specify): Visual ~ Industry Code or Engineering Standard (Specify): PEIRP1200 D Engineered Method (Specify): Attach the testing procedures and all documentation required to determine the results. I # of Attached Pages TANK ID: (By lank number. stored product, etc.) 87 S Fill 87 N Fill 91 Fill Diesel Fill Spill Container Manufacturer: PhilTite PhilTite PhilTite PhilTite Method of Cathodic Protection: !ill Non-Metallic ~ Non-Metallic ~ Non-Metallic ~ Non-Metallic 0 Isolation 0 Isolation 0 Isolation 0 Isolation D Other (Specify in V.) D Other (Specify in V.) D Other (Specify in V.) D Other (Specify in V.) Inside Diameter of Spill Container: (Inches) 12" 12" 12" 12" Depth of Spill Container: (Inches) 14" 14" 14" 14" Does the spill container have a 5 gallon capacity? @Yes ONo @Yes ONo @Yes ONo ~Yes ONo Method to Keep Spill Container Empty: ~ Drain Valve !ill Drain Valve ~ Drain Valve ~ Drain Valve Onsite Pump D 0nslte Pump D Onsite Pump D 0nsite Pump D Other (Specify 111 V.J D Other (Specify in V.J D Other /Specify in V.) D Other (Specify In V.) IV. SUMMARY OF TESTING RESULTS Spill Container Test Results: ~Pass • v. COMMENTS Any items marked "Fail" above must be explained in this section. Any additional comments may also be provided here. Replaced and re-tested 91 drain valve assembly. VI. CERTIFICATION BY UST SERVICE TECHNICIAN CONDUCTING THIS TESTING I hereby certify that the spill containers were tested in accordance with California Code of Regulations, Title 23, Division 3, Chapter 16, Section 2637.1 and all the information contained herein is accurate. UST Service Technician Signature D_:_V ~ ...,V\__ ___ If the facility has more components than this form accommodates, additional copies of this page may be attached. GERS " California Environments.I Reporting System, ID " Identification, UST= Underground Storage Tank, ICC = International Code Council UNDERGROUND STORAGE TANK SPILL CONTAINER TESTING REPORT FORM (Page1 of1) Type of Action D Installation Test D Repair Test ~ 12 Month Test I. FACILITY INFORMATION CERSID 10123132 Date of Spill Container Test 11/19/2019 Business Name (Same as Facility Name or DBA-Doing Business As) Foods Co # 384 Business Site Address 2501 Haley St. City Bakersfield ZIP Code CA II. UNDERGROUND STORAGE TANK SERVICE TECHNICIAN INFORMATION Name of UST Service Technician Performing the Test (Print as shown 011 tile ICC CMification,) David Walker Phone# Contractor I Tank Tester License# 808313 ICC Certification # 8854235 ICC Certification Expiration Dale 12/10/2020 Spill Container Testing Training and Certifications (List applicable certifications.) See Attached 111. SPILL CONTAINER TESTING INFORMATION Test Method Used: D Manufacturer Guidelines (Specify): Visual ~ Industry Code or Engineering Standard (Specify): PEI RPl200 O Engineered Method (Specify): Attach the testing procedures and all documentation required to determine the results. # of Attached Pages TANK ID: (By lank number, s/ored product, etc.) Spill Container Manufacturer: Method of Cathodic Protection: Inside Diameter of Spill Container: (Inches) Depth of Spill Container: (Inches) 87 S Vapor PhilTite ~ Non-Metallic D Isolation D Other (Specify in V.) 12" 87 N Vapor PhilTite ~ Non-Metallic D Isolation 0 Other (Specify in V.) 12" 14" 14" 91 Vapor PhilTite ~ Non-Metallic D Isolation D Other (Specify in V.) 12" 14" 0 Non-Metallic D Isolation D Other (Specify in V,) t:>oes the spill container have a 5 gallon capacity? Method to Keep Spill Container Empty: ~ Yes D No 1r~c=v"v_e_s--,•=,-N-o""'ih=-v-e-s--.=•,,-N-o-11,=;,Y-e-s ----;,•=.-N-0--1 ~ Drain Valve ~ Drain Valve ~ Drain Valve D Onsite Pump Onsite Pump D Onsite Pump 0 Other (Specify in V.) Other (Specify in V,) 0 Other (Specify in V.) IV. SUMMARY OF TESTING RESULTS Spill Container Test Results: V. COMMENTS D Drain Valve D Onsite Pump 0 Other (Specify In V.J Any items marked "Fail" above must be explained in this section. Any additional comments may also be provided here. VI. CERTIFICATION BY UST SERVICE TECHNICIAN CONDUCTING THIS TESTING I hereby certify that the spill containers were tested in accordance with California Code of Regulations, Title 23, Division 3, Chapter 16, Section 2637.1 and all the information contained herein is accurate. UST Service Technician Signature If the fac/1/ty has more components than this form accommodates, additional copies of this page may be attached. CERS = California Environmental Reportlng System, ID= Identification, UST= Underground Storage Tank, ICC= International Code Council Name Walker, David Walker, David Walker, David Walker, David Walker, David Walker, David Walker, David Walker, David Walker, David Walker, David Walker, David Walker, David Walker, David Walker, David Walker, David Walker, David Manufacturer Training Training NOV FiberGlass Systems Piping (Formerly AO S ICC California UST Service Technician ICC Vapor Recovery System Installation and Rep INCON Level 2 -FMS Programming INCON Level 1 -FMS Installation (EVO) Xerxes UST Installation Training Seminar Veeder Root Level 2/3/4 INCON Level 4 -Franklin Sump Test System PEI RP1200 Testing/Verification of UST Equipme Vaporless LDT-890 Leak Detector Tester Vaporless Mechanical LLD Installer Modern Welding Tank Installation ICC Vapor Recovery System Testing and Repair OPW EVR Phase I -UST Franklin Fueling Phase I -VR-101 (Formerly Phil OPW Fueling Containment Systems -FlexWorks Completed 6/22/2017 12/8/2017 1/11/2018 1/4/2018 5/2/2018 9/14/2018 10/25/2018 11/5/2018 11/3/2018 11/1/2018 11/1/2018 12/6/2018 3/3/2019 5/2/2019 7/19/2019 8/2/2019 Expires 6/22/2020 12/8/2019 1/11/2020 1/4/2020 5/2/2020 9/14/2021 10/25/2020 11/5/2020 11/3/2021 11/1/2020 11/1/2020 12/6/2021 3/3/2021 5/2/2021 7/19/2021 8/2/2021 BUSINESS NAME: FOODSCO FUEL CENTER #384 SITE ADDRESS: 2501 HALEY STREET I CITY: BAKERSFIELD I ZIP: 93305 MAP DATE: 2/22/19 I SURVEYED BY: FB I DRAWN BY: CT I FACILITY ID#: 10,000 DIESEL 8,000 PREMIU Driveway 7/8 L4:Disp 7-8 Dual 54:Disp 7-8 VFM 5/6 L3:Disp 5-6 Dual 53:Disp 5-6 VFM 3/4 L2:Disp 3-4 Dual 52:Disp 3-4 VFM 1/2 Ll:Disp 1-2 Dual 51:Disp 1-2 VFM Vent L22:Vent Sump 515:PMC Canister L23:Vent Sump Brine_ ~ ..-, ,,,o..._ I ~ DSL Reg_ular 20k f '?. I • • l ..1 I L18:Diesel Turbine L8:87 Turb~ne . .-----..,..;.:-•, 11 ?"O~-I L19:Diesel Turbine Brir~f 87 Tu_rbme Brine '• ,' I I ,99, I L20:Diesel Fill 0:87 F~II . I -~-, I ::0 I L21:Diesel Fill Brine Lll:87 Fill Brine •'o :+ 'is~ 514:Diesel Product L1 2:87 Annular \ '-.. ,' j 11 co I 517:Diesel Vent 59:87 Product -;-./ • g 91 510:87 91 Vapor 1,,-'.-tll ::0 I L13:91 Turbine 511:87 Vent I'~.'?,• 111,,··, I L14:91 T_urbine Brine .-. , • L15:91 Fill .-----•--. ~ I I '-.. ,,'I L16:91 Fill Brine ~--• --. / L17:91DieseIAnnular "11 0 0 0 "' I 512:91 Product ""' ... 513:91 Vent PARKING LOT ~ • ""'I ---MI ' .__ 13/14 ~L7:Disp 13-14 Dual 57:Disp 13-14 VFM 58:Disp 13-14 PS ~ 11/12 ~L6:Disp 11-12 Dual '"'56:Disp 11-12 VFM o 9/10 :::'._ L5:Disp 9-10 Dual en 55:Disp 9-10 VFM 0 !!I 0 ::0 m **NOTE: All PIPING LOCATIONS ARE ESTIMATED & SCALING IS APPROXIMATE** N CARBON CANNISTER - U DISPENSER VENT RISER v[;;] VENT BOX PRODUCT PIPING VAPOR RETURN/ VENT LINE • MONITORING PANEL ANNULAR A SENSOR FILL SUMP F SENSOR TURBINE T SUMP SENSOR HEIGHT STREET VEEDER ROOT L LINE LEAK VEEDER ROOT TLS-350R DETECTOR PLLD (8484) VEEDER ROOT VEEDER ROOT 794380-303 u UDC SENSOR 794380-323 (SUMP) 794380-304 (INTERSTITIAL) VEEDER ROOT VENT BOX VEEDER ROOT 794380-323 (SUMP) V SENSOR 794380-323 (SUMP) 794380-304 (INTERSTITIAL) 794380-304 (INTERSTITIAL) VEEDER ROOT ALL LINES MONITORED UNDER VACUUM 794380-323 (SUMP) SENSOR 330020-463. 794380-304 (INTERSTITIAL) Bel shire TLS Poll er SYSTEM SETUP Command Set ver 5 .12 Started at 11/19/2019 11: 19: 09 AM 110200 NOV 19, 2019 11: 18 AM FOODS CO, 384 2501 HALEY BAKERSFIELD CA. 661-873-9343 SYSTEM CONFIGURATION SLOT 1 2 1 5 6 7 ~ 10 11 12 13 14 15 16 BOARD TYPE 4 PROBE / G.T. PLLD SENSOR BD INTERSTITIAL BD INTERSTITIAL BO INTERSTITIAL BO 8SMARTSENSOR BO 7SMARTSENSOR BO 8SMARTSENSOR BO COMBO I/0 BOARD PLLD POWER BO UNUSED UNUSED UNUSED UNUSED UNUSED UNUSED COMM 1 ELEC DISP INT, COMM 2 SERIAL SAT BO COMM 3 UNUSED COMM 4 UNUSED COMM 5 RS485 SERIAL BO COMM 6 RS232 SERIAL BO 110100 NOV 19, 2019 11:18 AM FOODS CO, 384 2501 HALEY BAKERSFIELD CA. 661-873-9343 SYSTEM STATUS REPORT T 3: SUDDEN LOSS ALARM T 3: PROBE OUT I50100 NOV 19, 2019 11: 18 AM SYSTEM DATE AND TIME 150200 NOV 19, 2019 11:18 AM 150300 NOV 19, 2019 11: 18 AM I50400 NOV 19, 2019 11:18 AM 232 SECURITY CODE PORT SECURITY CODE 1 000000 2 000000 3 000000 4 000000 5 000000 6 000000 150500 NOV 19, 2019 11: 18 AM STATUS DISABLED DISABLED DISABLED DISABLED DISABLED DISABLED SYSTEM TYPE AND LANGUAGE FLAG SYSTEM UNITS U.S. SYSTEM LANGUAGE ENGLISH ~6~T5~ ~◊W~~~~l~~M~i I50600 NOV 19, 2019 11: 18 AM PERIODIC TEST WARNINGS: DISABLED 150700 NOV 19, 2019 11:18 AM PERIODIC TEST WARNING: DAYS 2 5 I50800 NOV 19, 2019 11:18 AM PERIODIC TEST ALARM: DAYS 30 I50900 NOV 19, 2019 11: 18 AM ANNUAL TEST WARNINGS: DISABLED I50A00 NOV 19, 2019 11: 18 AM ANNUAL TEST WARNING: DAYS 355 I50B00 NOV 19, 2019 11:18 AM ANNUAL TEST ALARM: DAYS 365 I50c00 NOV 19, 2019 11:18 AM POWER ON RESET 164807 3919 202970 203082 203127 39544 514845 9949365 9928 102072 9852763 9870287 9798228 9823814 9765830 9798012 101521 9786178 9767641 9753587 68839 15029 CURRENT 163215 3922 201176 201686 201431 39392 509850 39481 9942 101796 8413409 8398860 8399103 ~mg~i 8403783 101095 485954 8402525 84mbl 15013 Page 1 REMOTE PRINTER DISABLED I50D00 NOV 19, 2019 11:18 AM PRINT TC VOLUMES ENABLED I50EOO NOV 19, 2019 11: 18 AM TEMP COMPENSATION VALUE (DEG F ) : 60.0 I50F00 NOV 19, 2019 11:18 AM MON DD YYYY HH:MM:SS XM I51100 NOV 19, 2019 11:18 AM SHIFT BIR PRINTOUTS DISABLED 151200 NOV 19, 2019 11: 18 AM DAILY BIR PRINTOUTS DISABLED 151300 NOV 19, 2019 11: 18 AM I51400 NOV 19, 2019 11: 18 AM H-PROTOCOL DATA FORMAT HEIGHT I51500 NOV 19, 2019 11: 18 AM I51600 NOV 19, 2019 11: 18 AM RE-DIRECT LOCAL PRINTOUT DISABLED I51700 NOV 19, 2019 11: 18 AM SYSTEM TYPE AND LANGUAGE FLAG SYSTEM UNITS U.S. SYSTEM LANGUAGE ENGLISH SYSTEM DATE/TIME FORMAT MON DD YYYY HH:MM:SS XM I51800 ~E¥E~~AT~0t?NMJ..~~ ~~DE PAGE CODE PAGE SELECTED: WINDOWS I51900 NOV 19, 2019 11: 18 AM PRECISION TEST DURATION HOURS: 12 I51A00 NOV 19, 2019 11:18 AM DAYLIGHT SAVING TIME ENABLED OFF I51B00 NOV 19, 2019 11: 18 AM DAYLIGHT SAVING TIME START DATE MAR WEEK END DATE NOV WEEK I51c00 NOV 19, 2019 11: 18 AM TICKETED DELIVERY DISABLED I51D00 NOV 19, 2019 11: 18 AM I51E00 NOV 19, 2019 11: 18 AM I52000 NOV 19, 2019 11: 18 AM 1 SUN 2:00 SUN 2:00 RECEIVER AUTO DIAL TYPE & START TIME LOCATION LABEL system setup DIAL TYPE ON DATE ON DATE ON DATE ON DATE ON DATE AM AM START TIME JAN 5, 2011 JAN 5, 2011 JAN 5, 2011 JAN 5, 2011 JAN 5, 2011 DISABLED DISABLED DISABLED DISABLED DISABLED I52100 NOV 19, 2019 11: 18 AM RECEIVER CONFIGURATION ON DATE ON DATE ON DATE JAN 5, 2011 JAN 5, 2011 JAN 5, 2011 DEVICE LABEL 1 CONFIGURED OFF 2 3 1 7 8 I52200 NOV 19, 2019 11: 18 AM RECEIVER LABEL LABEL 152300 NOV 19, 2019 11:18 AM RECEIVER TELEPHONE NUMBER RCVR LOCATION LABEL 1 2 l 6 7 8 152400 NOV 19, 2019 11:18 AM OFF OFF OFF OFF OFF OFF OFF PHONE NUMBER RECEIVER DIALING DESTINATION TYPE RCVR LOCATION LABEL 1 l 7 8 152500 NOV 19, 2019 11: 18 AM FAX TYPE COMPUTER COMPUTER COMPUTER COMPUTER COMPUTER COMPUTER COMPUTER COMPUTER RECEIVER MODEM NUMBER TO DIAL RCVR LOCATION LABEL 1 I 5 6 7 8 152600 NOV 19, 2019 11: 18 AM RECEIVER RETRY NUMBER RCVR LOCATION LABEL 1 2 ¾ 5 6 7 8 152700 NOV 19, 2019 11: 18 AM RECEIVER RETRY DELAY TIME RCVR LOCATION LABEL 1 2 3 4 5 6 7 8 152800 NOV 19, 2019 11: 18 AM PORT fUMBER 1 1 1 1 1 RETRY NUMBER 3 3 3 3 3 3 3 3 RETRY DELAY 3 3 ~ 3 3 3 3 RECEIVER CONFIRMATION REPORT FLAG RCVR LOCATION LABEL ½ ¾ 5 6 7 8 I52900 NOV 19, 2019 11: 18 AM ALL PHONES I52A00 NOV 19, 2019 11: 18 AM RECEIVER REPORT LIST RCVR LOCATION LABEL CONFIRMATION OFF OFF OFF OFF OFF OFF OFF OFF REPORT LIST REPORT DISABLED DISABLED DISABLED Page 2 I52B00 NOV 19, 2019 11: 18 AM RECEIVER AUTO DIAL TYPE & START TIME RCVR LOCATION LABEL 1 2 I I52C00 NOV 19, 2019 11: 18 AM RECEIVER SETUP REPORT D 1: -NO ALARM ASSIGNMENTS - D 2: NO ALARM ASSIGNMENTS - D 3: -NO ALARM ASSIGNMENTS - D 4: -NO ALARM ASSIGNMENTS - D 5: -NO ALARM ASSIGNMENTS - D 6: -NO ALARM ASSIGNMENTS D 7: -NO ALARM ASSIGNMENTS - D 8: -NO ALARM ASSIGNMENTS - I52D00 NOV 19, 2019 11: 18 AM DIAL TYPE ON DATE ON DATE ON DATE ON DATE ON DATE ON DATE ON DATE ON DATE RECEIVER AUTODIAL ALARM STATUS RCVR STATUS 1 CLEAR 2 CLEAR 3 CLEAR 4 CLEAR 5 CLEAR 6 CLEAR 7 CLEAR 8 CLEAR I52EOO NOV 19, 2019 11: 18 AM FOODS CO. 384 2501 HALEY BAKERSFIELD CA. 661-873-9343 START TIME JAN 5, 2011 JAN 5, 2011 JAN 5, 2011 JAN 5, 2011 JAN 5, 2011 JAN 5, 2011 JAN 5, 2011 JAN 5, 2011 RECEIVER CLEARED ALARMS REPORT DELAY PERIOD RCVR LOCATION LABEL 1 2 l ~ 8 I52F00 NOV 19, 2019 11: 18 AM RECEIVER ALARM STATUS D 1: SERVICE REPORT WARN: CLEAR ALARM CLEAR WARNING: CLEAR DELIVERY REPORT WRN: CLEAR NO DIAL TONE ALARM : CLEAR D 2: SERVICE REPORT WARN: CLEAR ALARM CLEAR WARNING: CLEAR DELIVERY REPORT WRN: CLEAR NO DIAL TONE ALARM : CLEAR D 3: SERVICE REPORT WARN: CLEAR ALARM CLEAR WARNING: CLEAR DELIVERY REPORT WRN: CLEAR NO DIAL TONE ALARM : CLEAR D 4: SERVICE REPORT WARN: CLEAR ALARM CLEAR WARNING: CLEAR DELIVERY REPORT WRN: CLEAR NO DIAL TONE ALARM : CLEAR D 5: SERVICE REPORT WARN: CLEAR ALARM CLEAR WARNING: CLEAR DELIVERY REPORT WRN: CLEAR NO DIAL TONE ALARM : CLEAR D 6: SERVICE REPORT WARN: CLEAR ALARM CLEAR WARNING: CLEAR DELIVERY REPORT WRN: CLEAR NO DIAL TONE ALARM : CLEAR D 7: SERVICE REPORT WARN: CLEAR ALARM CLEAR WARNING: CLEAR DELIVERY REPORT WRN: CLEAR NO DIAL TONE ALARM : CLEAR D 8: SERVICE REPORT WARN: CLEAR ALARM CLEAR WARNING: CLEAR DELIVERY REPORT WRN: CLEAR NO DIAL TONE ALARM : CLEAR system setup DELAY PERIOD 48 48 48 48 48 48 48 48 DISABLED DISABLED DISABLED DISABLED DISABLED DISABLED DISABLED DISABLED I53000 NOV 19, 2019 11:18 AM I53100 NOV 19, 2019 11: 18 AM RS-232 END OF MESSAGE DISABLED I53200 NOV 19, 2019 11: 18 AM I53300 NOV 19, 2019 11: 18 AM I53400 NOV 19, 2019 11: 18 AM I53600 NOV 19, 2019 11:18 AM I53700 NOV 19, 2019 11: 18 AM I53800 NOV 19, 2019 11: 18 AM I54600 NOV 19, 2019 11: 18 AM TANK PER TST NEEDED WRN: I54700 NOV 19, 2019 11: 18 AM TANK PER TST NEEDED WRN: I54800 NOV 19, 2019 11:18 AM DISABLED DAYS TANK PER TST NEEDED ALM: DAYS I54900 NOV 19, 2019 11: 18 AM TANK ANN TST NEEDED WRN: DISABLED I54A00 NOV 19, 2019 11:18 AM 25 30 TANK ANN TST NEEDED WRN: DAYS 355 I54B00 NOV 19, 2019 11:18 AM TANK ANN TST NEEDED ALM: I54C00 NOV 19, 2019 11: 18 AM 9999FF1B I55300 NOV 19, 2019 11:19 AM LINE RE-ENABLE METHOD PASS LINE TEST I55400 NOV 19, 2019 11:19 AM I55500 NOV 19, 2019 11: 19 AM I55600 NOV 19, 2019 11: 19 AM DAYS 365 LINE PER TST NEEDED WRN: DISABLED I55700 NOV 19, 2019 11: 19 AM LINE PER TST NEEDED WRN: DAYS 25 I55800 NOV 19, 2019 11: 19 AM LINE PER TST NEEDED ALM: DAYS 30 I55900 NOV 19, 2019 11:19 AM LINE ANN TST NEEDED WRN: DISABLED I55A00 NOV 19, 2019 11:19 AM LINE ANN TST NEEDED WRN: DAYS 355 Page 3 I55B00 NOV 19, 2019 11:19 AM LINE ANN TST NEEDED ALM: DAYS 365 9999FF1B I56000 NOV 19, 2019 11: 19 AM MASS/DENSITY DISABLED I56400 NOV 19, 2019 11:19 AM ULLAGE: 90% I56500 NOV 19, 2019 11: 19 AM MAINTENANCE HISTORY DISABLED I56600 NOV 19, 2019 11:19 AM SERVICE NOTICE: DISABLED I56700 NOV 19, 2019 11: 19 AM I56800 NOV 19, 2019 11: 19 AM I56900 NOV 19, 2019 11: 19 AM I56AOO NOV 19, 2019 11:19 AM I5BC00 NOV 19, 2019 11: 19 AM RECEIVER SETUP REPORT D 1: -NO ALARM ASSIGNMENTS - D 2: -NO ALARM ASSIGNMENTS - D 3: -NO ALARM ASSIGNMENTS - D 4: -NO ALARM ASSIGNMENTS - D 5: -NO ALARM ASSIGNMENTS - D 6: -NO ALARM ASSIGNMENTS - D 7: -NO ALARM ASSIGNMENTS - D 8: -NO ALARM ASSIGNMENTS - I5BD00 NOV 19, 2019 11: 19 AM CUSTOM ALARM LABELS DISABLED I5BE00 NOV 19, 2019 11:19 AM I5BF00 NOV 19, 2019 11: 19 AM I5E200 NOV 19, 2019 11: 19 AM I60100 NOV 19, 2019 11: 19 AM TANK CONFIGURATION DEVICE 1 2 3 4 I60200 LABEL unleaded Premuim Diesel NOV 19, 2019 11:19 AM TANK PRODUCT LABEL I60300 PRODUc;T LABEL Unl eaQed Premu1m Diesel NOV 19, 2019 11: 19 AM TANK PRODUCT CODE system setup CONFIGURED ON ON ON OFF TrK e~9~~a~/ABEL 2 Premu,m 3 Diesel 4 160400 NOV 19, 2019 11: 19 AM TANK FULL VOLUME TANK 1 2 J 160500 NOV 19, 2019 11:19 AM TANK 4 POINT VOLUMES TA1NK PRODU<;T LABEL Unl ea\led 2 Premu,m 1 Diesel 160600 NOV 19, 2019 11: 19 AM TANK 20 POINT VOLUMES TfNK e~9~~~~/ABEL Premuim Diesel I60700 NOV 19, 2019 11: 19 AM TANK DIAMETER TANK 1 2 J I60800 PRODU<;T LABEL Unl ea11ed Premu,m Diesel NOV 19, 2019 11: 19 AM TANK TILT TANK 1 2 1 160900 NOV 19, 2019 11:19 AM TANK THERMAL COEFFICIENT TANK 1 2 3 4 I60A00 PRODUc;T LABEL unl ea\led bi:~~1m NOV 19, 2019 11: 19 AM TANK FULL VOLUME A B C 4 GALLONS 19782 7901 10420 0 19782 7901 10428 19782 0 0 0 0 7901 0 0 0 0 10420 INCHES 118. 35 118. 35 118. 38 o.oo INCHES 0.00 o.oo o.oo o.oo 0 0 0 0 0 0 0 0 0 0. 000700 0. 000700 0. 000450 0. 000000 GALLONS 16033 6356 8506 GALLONS 0 16033 0 0 0 0 6356 0 0 0 0 8505 0 0 0 0 0 0 0 0 9897 3964 5192 0 0 0 9897 0 0 0 0 3964 0 0 0 0 5192 0 0 0 0 0 0 0 TANK 4.PTS D1 esel 1 PT PRODUCT LABEL 19782 2 Premui!ANK PROFILE GALLONS 1 4 PTS 10420 4 4 PTS 0 I60B00 NOV 19, 2019 11:19 AM STICK HEIGHT OFFSET ENABLE STATUS DISABLED I60C00 NOV 19, 2019 11: 19 AM TANK TANK 1 2 J I60EOO NOV 19, 2019 11: 19 AM CUSTOM FLOAT PARAMETERS INCHES o.oo o.oo o.oo o.oo TANK WATER OFFSET FUEL OFFSET 3 99.000 99.000 I60F00 NOV 19, 2019 11: 19 AM PROBE OFFSET TANK PR!)DU<;T LABEL 1 Un I ea\led 2 Premu,m INCHES 0.00 o.oo INVALID FUEL 99. 000 3741 1560 1898 0 0 0 3741 0 0 0 0 1560 0 0 0 0 1890 0 0 0 0 0 0 WATER MINIMUM 99 .000 Page 4 3 Diesel 4 161000 NOV 19, 2019 11:19 AM TANK DELIVERY DELAY TANK 1 2 1 161100 PR!)DUc;T LABEL Un lea11ed Premu,m Diesel NOV 19, 2019 11: 19 AM LEAK TEST METHOD TEST ON DATE : ALL TANK mR.Pfr~~l? DISABLED TEST RATE : 0. 20 GAL/HR DURATION : 2 HOURS TST EARLY STOP: DISABLED 161200 NOV 19, 2019 11:19 AM TANK MANIFOLDED PARTNERS TANK TANKS 1 2 3 4 161300 PRODUCT LABEL unlea<jed bi~~~101 NOV 19, 2019 11: 19 AM CSLD PROBABLITY OF DETECTION 161400 NOV 19, 2019 11: 19 AM CSLD CLIMATE FACTOR 161500 NOV 19, 2019 11:19 AM TANK 1 2 1 161600 e~9~~~~/ABEL Premu,m Diesel NOV 19, 2019 11: 19 AM TANK PRODUc;T LABEL 1 unl ea11ed ~ bf:;~1m 4 161800 NOV 19, 2019 11: 19 AM 161900 NOV 19, 2019 11: 19 AM I61A00 NOV 19, 2019 11: 19 AM IN-TANK LEAK TEST EARLY STOP I61B00 PRODUCT LABEL Unl ea<;led Premu,m Diesel NOV 19, 2019 11: 19 AM 0.00 0.00 SIPHON MANIFOLDED TANKS NONE NONE NONE NONE METER DATA NO NO NO NO CAL UPDATE IMMEDIATE IMMEDIATE IMMEDIATE IMMEDIATE TST EARLY STOP: DISABLED DISABLED DISABLED DISABLED IN-TANK LEAK GROSS TEST AUTO-CONFIRM I61C00 NOV 19, 2019 11: 19 AM CSLD REPORT ONLY I61D00 NOV 19, 2019 11:19 AM TANK MANIFOLDED PARTNERS I61E00 PRODUCT LABEL Unl ea<;led Premu,m Diesel NOV 19, 2019 11: 19 AM 162100 NOV 19, 2019 11: 19 AM TANK LOW PRODUCT LIMIT TANK 1 2 3 4 162200 system setup SIPHON MANIFOLDED TANKS NONE NONE NONE NONE GALLONS ~38 25/i LINE MANIFOLDED NONE NONE NONE NONE LINE MANIFOLDED NONE NONE NONE NONE NOV 19, 2019 11:19 AM TANK HIGH PRODUCT LIMIT TANK PR!)DUc;T LABEL 1 Un I eaQed 2 Premu,m 3 oiesel 4 162300 NOV 19, 2019 11:19 AM TANK OVERFILL LEVEL LIMIT PRODUCT LABEL ~~!~~1~d Diesel 162400 NOV 19, 2019 11:19 AM TANK HIGH WATER LEVEL LIMIT 162500 (;~9~~~!/ABEL Premu,m Diesel NOV 19, 2019 11:19 AM TANK SUDDEN LOSS LIMIT TANK 1 2 l 162600 PRODUc;T LABEL Unl eaQed Premu1m Diesel NOV 19, 2019 11: 19 AM TANK LEAK ALARM LIMIT 162700 PRODUc;T LABEL Unl eaQed Premu,m Diesel NOV 19, 2019 11: 19 AM TANK HIGH WATER WARNING LIMIT TANK PRODUCT LABEL 1 unlea~ed ~ bi:~~~m 162800 NOV 19, 2019 11: 19 AM TANK MAXIMUM VOLUME LIMIT TANK 1 2 l PRODUc;T LABEL Unl eaQed Premu1m Diesel 162900 NOV 19, 2019 11: 19 AM TANK TANK 1 2 3 4 DELIVERY REQUIRED PR!)DUc;T LABEL Unl eaQed Premu,m Diesel I62A00 NOV 19, 2019 11: 19 AM LIMIT ANNUAL LEAK TEST MIN VOLUME 162800 PRODUc;T LABEL Unl eaQed Premu1m Diesel NOV 19, 2019 11:19 AM TANK LAST ANNUAL TEST TANK 1 2 l I62c00 PRODUCT LABEL Unl ea~ed Premu1m Diesel NOV 19, 2019 11: 19 AM TANK PERIODIC TEST TYPE TANK 1 2 l I62D00 NOV 19, 2019 11: 19 AM TANK LEAK TEST FAIL ALARMS TtNK 0~9~~auABEL Premuim Diesel GALLONS 18793 7506 9899 0 GALLONS 17803 7110 9378 0 INCHES 3.0 3.0 3.0 GALLONS I~ GALLONS 15 15 15 99 INCHES 1.0 1.0 1.0 GALLONS 19782 7901 10420 0 GALLONS 2967 1185 1042 0 GALLONS 989 395 494 0 DATE ~~~ 0, ??? 8: ??? 0, 8 0 PERIODIC TEST TYPE STANDARD STANDARD STANDARD STANDARD GROSS TEST FAIL PERIODIC TEST FAIL ANNUAL TEST FAIL GROSS TEST FAIL PERIODIC TEST FAIL ANNUAL TEST FAIL GROSS TEST FAIL PERIODIC TEST FAIL ANNUAL TEST FAIL ALARM DISABLED ALARM DISABLED ALARM DISABLED ALARM DISABLED ALARM DISABLED ALARM DISABLED ALARM DISABLED ALARM DISABLED ALARM DISABLED Page 5 I62EOO NOV 19, 2019 11:19 AM GROSS TEST FAIL PERIODIC TEST FAIL ANNUAL TEST FAIL CAPO PROBE CONDUCTIVE BOOT FLAG TANK PRODUCT LABEL I62F00 NOV 19, 2019 11: 19 AM MAG PROBE FLOAT SIZE TANK PRODUaT LABEL 1 unl ea ed 2 Premu,m 3 Diesel 163000 NOV 19, 2019 11:19 AM IN-TANK LEAK TEST NOTIFY TANK /;~9~~~!d LABEL 1 2 bi~~~lm 3 4 163100 NOV 19, 2019 11:19 AM TANK LEAK TEST AVERAGING TANK 1 2 3 4 163200 (;~9~~~!/ABEL Premu1m Diesel NOV 19, 2019 11: 19 AM TANK TEST SIPHON BREAK 163300 NOV 19, 2019 11:19 AM CAPO CONDUCTIVE BOOT: FLOAT SIZE: 3.0 IN. 3.0 IN. 3.0 IN. TANK TEST NOTIFY: ANNUAL OFF OFF OFF OFF OFF OFF OFF OFF PERIODIC OFF OFF OFF OFF SIPHON BREAK OFF OFF OFF OFF LEAK TEST REPORT FORMAT: NORMAL 163400 NOV 19, 2019 11: 19 AM RECONCILIATION WARNING LIMIT TANK 1 2 3 4 163500 NOV 19, 2019 11: 19 AM RECONCILIATION ALARM LIMIT 163600 NOV 19, 2019 11: 19 AM PERIODIC LEAK TEST MIN VOLUME TANK 1 2 l 163900 PRODUc;T LABEL unl eaQed bi~~~lm NOV 19, 2019 11: 19 AM ACCU CHART END SHAPE FACTOR TtNK e~9~~a!/ABEL END FACTOR: NONE 2 Premuim END FACTOR: NONE 3 Diesel END FACTOR: NONE 4 END FACTOR: NONE I63A00 NOV 19, 2019 11:19 AM GALLONS 8 0 0 GALLONS 1 1 1 1 GALLONS 989 395 496 LOW LEVEL PUMP THRESHOLD FOR SEQUENTIAL LINE MANIFOLD system Setup PUMP THRESHOLD 10.00% 10.00% 10.00% 10.00% ALARM DISABLED ALARM DISABLED ALARM DISABLED 163800 ~2~/~6 ~gJc~lMJcM~ AND VOLUMES I63C00 NOV 19, 2019 11: 19 AM TANK 50 POINT FULL VOLUME 163000 NOV 19, 2019 11: 19 AM 9999FF18 168000 NOV 19, 2019 11: 19 AM FOODS CO. 384 2501 HALEY BAKERSFIELD CA. 661-873-9343 FUEL MANAGEMENT SETUP DELIVERY WARN DAYS: 0. 0 AUTO PRINT: DISABLED GALLONS ~ FUEL MANAGEMENT AVERAGE SALES (GALLONS) Unleaded ~ TANK 1 ) SUN MON TUE ED THR FRI SAT 0 0 0 0 0 0 0 Premuim ( TANK 2 ) SUN MON TUE WED THR FRI SAT 0 0 0 0 0 0 0 Diesel ( TANK 3 ) SUN MON TUE WED THR FRI SAT 0 0 0 0 0 0 0 168100 NOV 19, 2019 11: 19 AM 168200 NOV 19, 2019 11:19 AM 168300 NOV 19, 2019 11:19 AM 170100 NOV 19, 2019 11:19 AM LIQUID CONFIGURATION DEVICE LABEL CONFIGURED 1 DISP 1-2 DUAL ON 2 DISP 3-4 DUAL ON 3 DISP 5-6 DUAL ON 4 DISP 7-8 DUAL ON 5 DISP 9-10 DUAL ON 6 DISP 11-12 DUAL ON 7 DISP 13-14 DUAL ON 8 87 TURBINE ON 9 87 TURBINE BRINE ON 10 87 FILL ON 11 87 FILL BRINE ON 12 87 ANNULAR ON 13 91 TURBINE ON 14 91 TURBINE BRINE ON 15 91 FILL ON 16 91 FILL BRINE ON 17 91 DIESEL ANNULAR ON 18 DIESEL TURBINE ON 19 DIESEL TURBINE BRINE ON 20 DIESEL FILL ON 21 DIESEL FILL BRINE ON 22 VENT SUMP ON 23 VENT SUMP BRINE ON 24 OFF 170200 NOV 19, 2019 11: 19 AM LIQUID LABEL DEVICE LABEL 1 DISP 1-2 DUAL 2 DISP 3-4 DUAL 3 DISP 5-6 DUAL 4 DISP 7-8 DUAL 5 DISP 9-10 DUAL 6 DISP 11-12 DUAL 7 DISP 13-14 DUAL 8 87 TURBINE 9 87 TURBINE BRINE 10 87 FILL 11 87 FILL BRINE 12 87 ANNULAR 13 91 TURBINE 14 91 TURBINE BRINE 15 91 FILL 16 91 FILL BRINE 17 91 DIESEL ANNULAR 18 DIESEL TURBINE 19 DIESEL TURBINE BRINE 20 DIESEL FILL 21 DIESEL FILL BRINE 22 VENT SUMP 23 VENT SUMP BRINE 24 170300 NOV 19, 2019 11:19 AM LIQUID TYPE SENSOR LOCATION TYPE 1 DISP 1-2 DUAL OW SUMP 2-1 2 DISP 3-4 DUAL OW SUMP 2-1 3 DISP 5-6 DUAL OW SUMP 2-1 4 DISP 7-8 DUAL DW SUMP 2-1 5 DISP 9-10 DUAL OW SUMP 2-1 6 DISP 11-12 DUAL OW SUMP 2-1 7 DISP 13-14 DUAL OW SUMP 2-1 8 87 TURBINE TRI-STATE (SINGLE FLOAT) 9 87 TURBINE BRINE TRI-STATE (SINGLE FLOAT) 10 87 FILL TRI-STATE (SINGLE FLOAT) 11 87 FILL BRINE TRI-STATE (SINGLE FLOAT) 12 87 ANNULAR DUAL POINT HYDROSTATIC 13 91 TURBINE TRI-STATE (SINGLE FLOAT) 14 91 TURBINE BRINE TRI-STATE (SINGLE FLOAT) 15 91 FILL TRI-STATE (SINGLE FLOAT) 16 91 FILL BRINE TRI-STATE (SINGLE FLOAT) 17 91 DIESEL ANNULAR DUAL POINT HYDROSTATIC 18 DIESEL TURBINE TRI-STATE (SINGLE FLOAT) 19 DIESEL TURBINE BRINE TRI-STATE (SINGLE FLOAT) 20 DIESEL FILL TRI-STATE (SINGLE FLOAT) 21 DIESEL FILL BRINE TRI-STATE (SINGLE FLOAT) 22 VENT SUMP TRI-STATE (SINGLE FLOAT) 23 VENT SUMP BRINE TRI-STATE (SINGLE FLOAT) 24 TRI-STATE (SINGLE FLOAT) 170400 NOV 19, 2019 11:19 AM LIQUID CATEGORY SENSOR LOCATION CATEGORY 1 DISP 1-2 DUAL DISPENSER PAN 2 DISP 3-4 DUAL DISPENSER PAN 3 DISP 5-6 DUAL DISPENSER PAN 4 DISP 7-8 DUAL DISPENSER PAN 5 DISP 9-10 DUAL DISPENSER PAN 6 DISP 11-12 DUAL DISPENSER PAN 7 DISP 13-14 DUAL DISPENSER PAN 8 87 TURBINE STP SUMP 9 87 TURBINE BRINE STP SUMP 10 87 FILL PIPING SUMP 11 87 FILL BRINE PIPING SUMP 12 87 ANNULAR ANNULAR SPACE 13 91 TURBINE STP SUMP 14 91 TURBINE BRINE STP SUMP 15 91 FILL PIPING SUMP 16 91 FILL BRINE PIPING SUMP 17 91 DIESEL ANNULAR ANNULAR SPACE 18 DIESEL TURBINE STP SUMP 19 DIESEL TURBINE BRINE STP SUMP 20 DIESEL FILL PIPING SUMP 21 DIESEL FILL BRINE PIPING SUMP 22 VENT SUMP PIPING SUMP 23 VENT SUMP BRINE PIPING SUMP 24 OTHER SENSORS 170600 NOV 19, 2019 11: 19 AM 170700 NOV 19, 2019 11:19 AM 170800 NOV 19, 2019 11: 19 AM 170900 NOV 19, 2019 11:19 AM 171100 NOV 19, 2019 11:20 AM 171200 NOV 19, 2019 11: 20 AM 171300 NOV 19, 2019 11:20 AM 172100 NOV 19, 2019 11: 20 AM SMART SENSOR CONFIGURATION DEVICE LABEL CONFIGURED 1 DISP 1-2 VFM ON 2 DISP 3-4 VFM ON 3 DISP 5-6 VFM ON 4 DISP 7-8 VFM ON 5 DISP 9-10 VFM ON 6 DISP 11-12 VFM ON 7 gm H=U ~~M ON 8 ON 9 87 PRODUCT ON 10 87 91 VAPOR ON 11 87 VENT-CHASE ON 12 91 PRODUCT ON 13 91 VENT-CHASE ON 14 DIESEL PRODUCT ON 15 PMC CANISTER ON 16 ATM P ON 17 DIESEL VENT-CHASE ON Page 6 system setup 18 19 20 21 22 23 24 I72200 NOV 19, 2019 11: 20 AM SMART SENSOR LABEL DEVICE LABEL 1 DISP 1-2 VFM 2 DISP 3-4 VFM 3 DISP 5-6 VFM 4 DISP 7-8 VFM 5 DISP 9-10 VFM 6 DISP 11-12 VFM 7 DISP 13-14 VFM 8 DISP 13-14 PS 9 87 PRODUCT 10 87 91 VAPOR 11 87 VENT-CHASE 12 91 PRODUCT 13 91 VENT-CHASE 14 DIESEL PRODUCT 15 PMC CANISTER 16 ATM P 17 DIESEL VENT-CHASE 18 19 20 21 22 23 24 I72300 NOV 19, 2019 11:20 AM FOODS CO, 384 2501 HALEY BAKERSFIELD CA, 661-873-9343 SMARTSENSOR ASSIGNMENT DEVICE LABEL 01 DISP 1-2 VFM 02 DISP 3-4 VFM 03 DISP 5-6 VFM 04 DISP 7-8 VFM 05 DISP 9-10 VFM 06 DISP 11-12 VFM 07 DISP 13-14 VFM 08 DISP 13-14 PS 09 87 PRODUCT 10 87 91 VAPOR 11 87 VENT-CHASE 12 91 PRODUCT 13 91 VENT-CHASE 14 DIESEL PRODUCT 15 PMC CANISTER 16 ATM P 17 DIESEL VENT-CHASE 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 172700 NOV 19, 2019 11: 20 AM I72800 NOV 19, 2019 11: 20 AM 172900 NOV 19, 2019 11: 20 AM OFF OFF OFF OFF OFF OFF OFF CATEGORY AIR FLOW METER AIR FLOW METER AIR FLOW METER AIR FLOW METER AIR FLOW METER AIR FLOW METER AIR FLOW METER VAPOR PRESSURE VAC SENSOR VAC SENSOR VAC SENSOR VAC SENSOR VAC SENSOR VAC SENSOR VAPOR VALVE ATM P SENSOR VAC SENSOR UNKNOWN UNKNOWN UNKNOWN UNKNOWN UNKNOWN UNKNOWN UNKNOWN UNKNOWN UNKNOWN UNKNOWN UNKNOWN UNKNOWN UNKNOWN UNKNOWN UNKNOWN UNKNOWN UNKNOWN UNKNOWN UNKNOWN UNKNOWN UNKNOWN UNKNOWN UNKNOWN Page 7 VACUUM SENSOR PUMP NUMBER DEVIC§ 10 11 12 13 14 17 I72A00 LABEL 87 PRODUCT 87 91 VAPOR 87 VENT-CHASE 91 PRODUCT 91 VENT-CHASE DIESEL PRODUCT DIESEL VENT-CHASE NOV 19, 2019 11:20 AM VACUUM SENSOR VOLUME DEVICE 9 10 11 12 13 14 17 I72B00 NOV 19, VACUUM DEVICE 9 10 11 12 13 14 17 I72COO LABEL 87 PRODUCT 87 91 VAPOR 87 VENT-CHASE 91 PRODUCT 91 VENT-CHASE DIESEL PRODUCT DIESEL VENT-CHASE 2019 11: 20 AM SENSOR RELIEF VALVE LABEL 87 PRODUCT 87 91 VAPOR 87 VENT-CHASE 91 PRODUCT 91 VENT-CHASE DIESEL PRODUCT DIESEL VENT-CHASE NOV 19, 2019 11: 20 AM PUMP NUMBER Q 1: 87 UNLEADED Q 1: 87 UNLEADED Q 1: 87 UNLEADED Q 2: 91 UNLEADED Q 2: 91 UNLEADED Q 3 :DIESEL Q 3 :DIESEL VOLUME 57, 5 GALLONS 69, 0 GALLONS 29, 4 GALLONS 57, 5 GALLONS 25, 9 GALLONS 46.0 GALLONS 25. 9 GALLONS PRESENT RELIEF VALVE NO NO NO NO NO NO NO VACUUM SENSOR RELIEF VALVE PRESSURE DEVICE LABEL RELIEF VALVE PRESSURE 9 87 PRODUCT -9,0 PSI 10 87 91 VAPOR -9.0 PSI 11 87 VENT-CHASE -9.0 PSI 12 91 PRODUCT -9.0 PSI 13 91 VENT-CHASE -9.0 PSI 14 DIESEL PRODUCT -9.0 PSI 17 DIESEL VENT-CHASE -9.0 PSI 174100 NOV 19, 2019 11: 20 AM I74200 NOV 19, 2019 11:20 AM 174300 NOV 19, 2019 11: 20 AM I74400 NOV 19, 2019 11:20 AM 174600 NOV 19, 2019 11: 20 AM I74700 2019 11: 20 AM NOV 19, 174800 NOV 19, 2019 11: 20 AM I74900 NOV 19, 2019 11: 20 AM 174800 NOV 19, 2019 11: 20 AM I74cOO NOV 19, 2019 11: 20 AM 174D00 NOV 19, 2019 11: 20 AM I74EOO NOV 19, 2019 11: 20 AM I75100 NOV 19, 2019 11:20 AM 175200 NOV 19, 2019 11: 20 AM I75300 NOV 19, 2019 11: 20 AM 175400 NOV 19, 2019 11: 20 AM 175500 NOV 19, 2019 11: 20 AM system setup I75600 NOV 19, 2019 11:20 AM I75700 NOV 19, 2019 11: 20 AM I75800 NOV 19, 2019 11: 20 AM I75900 NOV 19, 2019 11: 20 AM I75A00 NOV 19, 2019 11:20 AM LINE LEAK LOCKOUT SETUP LOCKOUT SCHEDULE DAILY START TIME: DISABLED STOP TIME : DISABLED I75B00 NOV 19, 2019 11: 20 AM I75COO NOV 19, 2019 11:20 AM I75D00 NOV 19, 2019 11: 20 AM I75EOO NOV 19, 2019 11:20 AM I75FOO NOV 19, 2019 11: 20 AM 176000 NOV 19, 2019 11: 20 AM 176100 NOV 19, 2019 11: 20 AM I77100 NOV 19, 2019 11: 20 AM I77200 NOV 19, 2019 11:20 AM I77300 NOV 19, 2019 11:20 AM I77400 NOV 19, 2019 11:20 AM PLLD CONTINUOUS HANDLE TIMEOUT LINE Q 1: 87 UNLEADED Q 2: 91 UNLEADED Q 3:DIESEL I77500 NOV 19, 2019 11: 20 AM TIMEOUT 16 HOURS 3:g ~88~~ PRESSURE LINE LEAK PROFILE LINE TEST LEAK RATE LINE Q 1:87 UNLEADED Q 2: 91 UNLEADED Q 3 :DIESEL I77600 NOV 19, 2019 11: 20 AM TEST LEAK RATE 3.00 GPH 3.00 GPH 3.00 GPH PRESSURE LINE LEAK PROFILE LINE TEST REFERENCE PRESSURE LINE Q 1: 87 UNLEADED Q 2: 91 UNLEADED Q 3 :DIESEL I77700 NOV 19, 2019 11: 20 AM 177800 NOV 19, 2019 11: 20 AM 177900 NOV 19, 2019 11: 20 AM I77AOO NOV 19, 2019 11: 20 AM I77B00 NOV 19, 2019 11:20 AM I77COO NOV 19, 2019 11: 20 AM TESil!li ~~iSSURE 10.00 PSI 10.00 PSI Page 8 PRESSURE LINE LEAK LOW PRESSURE SHUTOFF LINE Q l: 87 UNLEADED Q 2: 91 UNLEADED Q 3 :DIESEL I77D00 NOV 19, 2019 11:20 AM LOW PRESSURE SHUTOFF NO NO NO ALTITUDE PRESSURE OFFSET ADJUSTMENT LINE Q 1: 87 UNLEADED Q 2: 91 UNLEADED Q 3 :DIESEL I77E00 NOV 19, 2019 11: 20 AM I77FOO NOV 19, 2019 11: 20 AM PRESSURE OFFSET 0. 0 PSI 0. 0 PSI 0.0 PSI PRESSURE LINE LEAK LINE LENGTH LARGE LINE Q 1: 87 UNLEADED Q 2: 91 UNLEADED Q 3 :DIESEL 178000 NOV 19, 2019 11: 20 AM PRESSURE LINE LEAK SETUP Q 1: 87 UNLEADED 1:m · g{l ·~I~: FmR~~N-s 3. OIN DIA LEN: 0 FEET SHUTDOWN RATE: 3.0 GPH LO,/ PRESSURE SHUTOFF: NO LO,i PRESSURE : 0 PSI T 1: Unleaded DISPENSE MODE: STANDARD SENSOR: HIGH PRESSURE PRESSURE OFFSET: 0. OPSI MECHANICAL BLENDER: NO Q 2: 91 UNLEADED TYP: 2. 0/3. OIN FIBERGLASS 2. QIN DIA LEN: 250 FEET 3. QIN DIA LEN: 0 FEET SHUTDO,iN RATE: 3.0 GPH LO,i PRESSURE SHUTOFF: NO LO,/ PRESSURE : T 2:Premuim DISPENSE MODE: STANDARD 0 PSI SENSOR: HIGH PRESSURE PRESSURE OFFSET: 0. OPSI MECHANICAL BLENDER: NO Q 3 :DIESEL TYP: 2. 0/3. OIN FIBERGLASS 2 • OIN DIA LEN: 200 FEET 3 • OIN DIA LEN: 0 FEET SHUTDOWN RATE: 3.0 GPH LO,/ PRESSURE SHUTOFF: NO LOW PRESSURE : T 3:Diesel DISPENSE MODE: STANDARD 0 PSI SENSOR: HIGH PRESSURE PRESSURE OFFSET: 0. OPSI MECHANICAL BLENDER: NO I78100 NOV 19, 2019 11: 20 AM PRESSURE LLD CONFIGURATION DEVICE LABEL 1 87 UNLEADED 2 91 UNLEADED 3 DIESEL 178200 NOV 19, 2019 11: 20 AM PRESSURE LLD LABEL DEVICE LABEL 1 87 UNLEADED 2 91 UNLEADED 3 DIESEL 178300 NOV 19, 2019 11: 20 AM 178400 NOV 19, 2019 11:20 AM LINE LENGTH 0 FEET 0 FEET 0 FEET CONFIGURED ON ON ON PRESSURE LINE LEAK SHUTDOWN RATE LINE Q 1: 87 UNLEADED Q 2: 91 UNLEADED Q 3: DIESEL 178500 NOV 19, 2019 11:20 AM SHUTDOWN RATE 3. 0 GPH 3 .0 GPH 3 .0 GPH PRESSURE LINE LEAK TANK NUMBER system Setup LINE Q 1: 87 UNLEADED Q 2: 91 UNLEADED Q 3 :DIESEL I78600 NOV 19, 2019 11: 20 AM TANK NUMBER ½ 3 PRESSURE LINE LEAK DISPENSE MODE LINE Q l: 87 UNLEADED Q 2: 91 UNLEADED Q 3: DIESEL 178700 NOV 19, 2019 11: 20 AM PRESSURE LLD SETUP REPORT Q 1:87 UNLEADED IN-TANK ALARMS T 1: HIGH WATER ALARM T 1: LOW PRODUCT ALARM LIQUID SENSOR ALMS L l: FUEL ALARM L 2: FUEL ALARM L 3: FUEL ALARM L 4: FUEL ALARM L 5: FUEL ALARM L 6: FUEL ALARM L 7: FUEL ALARM L 8: FUEL ALARM L 9: FUEL ALARM LlO: FUEL ALARM Lll: FUEL ALARM L22: FUEL ALARM L23: FUEL ALARM L l: SENSOR OUT ALARM L 2 ; SENSOR OUT ALARM L 3: SENSOR OUT ALARM L 4: SENSOR OUT ALARM L 5 : SENSOR OUT ALARM L 6: SENSOR OUT ALARM L 7: SENSOR OUT ALARM L 8: SENSOR OUT ALARM L 9: SENSOR OUT ALARM LlO: SENSOR OUT ALARM Lll: SENSOR OUT ALARM L22: SENSOR OUT ALARM L23: SENSOR OUT ALARM L 1: SHORT ALARM L 2 : SHORT ALARM L 3: SHORT ALARM L 4: SHORT ALARM L 5:SHORT ALARM L 6: SHORT ALARM L 7: SHORT ALARM L 8: SHORT ALARM L 9: SHORT ALARM LlO: SHORT ALARM Lll: SHORT ALARM Ll2 : SHORT ALARM L22: SHORT ALARM L23: SHORT ALARM t11: rli~H Li/i8~ti0 At~~:M L 2 : LOW LIQUID ALARM L 3: LOW LIQUID ALARM L 4: LOW LIQUID ALARM L 5 : LOW LIQUID ALARM L 6: LOW LIQUID ALARM L 7: LOW LIQUID ALARM Lll: LOW LIQUID ALARM Ll2 : LOW LIQUID ALARM PRESSURE LINE LEAK Q 1: PLLD OPEN ALARM SMARTSENSOR ALARMS slO: FUEL ALARM s 9: HIGH LIQUID ALARM slO: HIGH LIQUID ALARM ~1§: ~/iGMli8~I~L!~~RM slO: NO VACUUM ALARM sll:No VACUUM ALARM ISO SITE ALARMS ISD GROSS PRES FAIL ISO DEGRO PRES FAIL ISD VAPOR LEAK FAIL ISD VP PRES FAIL ISO VP STATUS FAIL ISO HOSE ALARMS ALL: FLO\v COLLECT FAIL Q 2: 91 UNLEADED IN-TANK ALARMS T 2: HIGH WATER ALARM T 2 : LOW PRODUCT ALARM L[ Q~7~u~[N~2:R~LMS L 2 FUEL ALARM L 3 FUEL ALARM L 4 FUEL ALARM L 5 FUEL ALARM L 6 FUEL ALARM L 7 FUEL ALARM Ll3 FUEL ALARM Ll4 FUEL ALARM L15 FUEL ALARM L16 FUEL ALARM Ll7 FUEL ALARM L22 FUEL ALARM L23 FUEL ALARM L 1 SENSOR OUT ALARM L 2 SENSOR OUT ALARM L 3 SENSOR OUT ALARM L 4 SENSOR OUT ALARM L 5 SENSOR OUT ALARM L 6 SENSOR OUT ALARM L 7 SENSOR OUT ALARM Ll3 SENSOR OUT ALARM Ll4 SENSOR OUT ALARM Ll5 SENSOR OUT ALARM Ll6 SENSOR OUT ALARM DISPENSE MODE STANDARD STANDARD STANDARD Page 9 Ll7 SENSOR OUT ALARM L22 SENSOR OUT ALARM L23 SENSOR OUT ALARM L l SHORT ALARM L 2 SHORT ALARM L 3 SHORT ALARM L 4 SHORT ALARM L 5 SHORT ALARM L 6 SHORT ALARM L 7 SHORT ALARM Ll3 SHORT ALARM Ll4 SHORT ALARM Ll5 SHORT ALARM Ll6 SHORT ALARM Ll7 SHORT ALARM L22 SHORT ALARM L23 SHORT ALARM t1i r5~\i@~5D At~~:M L 2 LOW LIQUID ALARM L 3 LOW LIQUID ALARM L 4 LOW LIQUID ALARM L 5 LOW LIQUID ALARM L 6 LOW LIQUID ALARM L 7 LOW LIQUID ALARM Ll7: LO\v LIQUID ALARM PRESSURE LINE LEAK Q 2: PLLD OPEN ALARM SMARTSENSOR ALARMS slO: FUEL ALARM sl2 : FUEL ALARM sl3: FUEL ALARM slO: HIGH LIQUID ALARM sl2: HIGH LIQUID ALARM sl3: HIGH LIQUID ALARM sl2 :NO VACUUM ALARM sl3: NO VACUUM ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRO PRES FAIL ISD VAPOR LEAK FAIL ISD VP PRES FAIL ISD VP STATUS FAIL ISD HOSE ALARMS ALL: FLOW COLLECT FAIL Q 3 :DIESEL IN-TANK ALARMS T 3: HIGH WATER ALARM T 3: LOW PRODUCT ALARM LIQUID SENSOR ALMS L 1: FUEL ALARM L 2: FUEL ALARM L 3: FUEL ALARM L 4: FUEL ALARM Ll7: FUEL ALARM Ll8: FUEL ALARM Ll9: FUEL ALARM L20: FUEL ALARM L21: FUEL ALARM L22: FUEL ALARM L23: FUEL ALARM L 1: SENSOR OUT ALARM L 2: SENSOR OUT ALARM L 3: SENSOR OUT ALARM L 4; SENSOR OUT ALARM Ll7: SENSOR OUT ALARM Ll8: SENSOR OUT ALARM Ll9: SENSOR OUT ALARM L20: SENSOR OUT ALARM L21:SENSOR OUT ALARM L22: SENSOR OUT ALARM L23: SENSOR OUT ALARM L 1: SHORT ALARM L 2 : SHORT ALARM L 3: SHORT ALARM L 4: SHORT ALARM Ll7: SHORT ALARM Ll8: SHORT ALARM Ll9: SHORT ALARM L20: SHORT ALARM L21: SHORT ALARM L22: SHORT ALARM L23: SHORT ALARM Ll7: HIGH LIQUID ALARM L 1: LOW LIQUID ALARM L 2: LOW LIQUID ALARM L 3: LOW LIQUID ALARM L 4: LOW LIQUID ALARM Ll7: LOW LIQUID ALARM PRESSURE LINE LEAK Q 3: PLLD OPEN ALARM SMARTSENSOR ALARMS sl4: FUEL ALARM sl7: FUEL ALARM sl4: HIGH LIQUID ALARM sl7: HIGH LIQUID ALARM sl4:No VACUUM ALARM sl7:NO VACUUM ALARM I78800 NOV 19, 2019 11: 21 AM PRESSURE LINE LEAK PIPE TYPE LINE Q 1: 87 UNLEADED Q 2: 91 UNLEADED Q 3 :DIESEL I78900 NOV 19, 2019 11: 21 AM PRESSURE LINE LEAK LINE LENGTH LINE Q 1: 87 UNLEADED Q 2 : 91 UNLEADED Q 3 :DIESEL I78A00 NOV 19, 2019 11:21 AM PRESSURE LINE LEAK system setup LINE LENGTH 250 FEET 250 FEET 200 FEET LINE Q 1: 87 UNLEADED Q 2: 91 UNLEADED Q 3:DIESEL 9999FF1B I78C00 NOV 19, 2019 11:21 AM I78E00 NOV 19, 2019 11:21 AM I78F00 NOV 19, 2019 11: 21 AM PUMP HIGH PRESSURE HIGH PRESSURE HIGH PRESSURE PRESSURE LINE LEAK DISPENSE THRESHOLD LINE Q 1:87 UNLEADED Q 2 :91 UNLEADED Q 3:DIESEL I79000 NOV 19, 2019 11: 21 AM LOW PRESSURE 0 PSI 0 PSI 0 PSI EDIM:l VR:330273-002-C TD:97.11,13.15.52 I79100 NOV 19, 2019 11:21 AM I79200 NOV 19, 2019 11: 21 AM DISP, MODULE DATA STRING EDIM 1: B9DNHG I79300 NOV 19, 2019 11: 21 AM AUTOMATIC DAILY CLOSING TIME: 2:00 AM I79400 NOV 19, 2019 11:21 AM I79500 NOV 19, 2019 11: 21 AM PERIODIC RECONCILIATION MODE: MONTHLY I79600 NOV 19, 2019 11: 21 AM PERIODIC RECONCILIATION LENGTH: 31 DAYS I79700 NOV 19, 2019 11: 21 AM PERIODIC RECONCILIATION ALARM: DISABLED I79800 NOV 19, 2019 11:21 AM PERIODIC RECONCILIATION ALARM THRESHOLD: 1. 00% I79900 NOV 19, 2019 11:21 AM PERIODIC RECONCILIATION ALARM OFFSET: 130 I79A00 NOV 19, 2019 11: 21 AM REMOTE REPORT FORMAT SELECT: ROW I79D00 NOV 19, 2019 11: 21 AM MANUAL SHIFT CLOSE I79EOO NOV 19, 2019 11:21 AM RECONCILIATION CLEAR MAP I79F00 NOV 19, 2019 11: 21 AM TEMP COMPENSATION STANDARD I7AOOO NOV 19, 2019 11:21 AM I7Al00 NOV 19, 2019 11: 21 AM I7A200 NOV 19, 2019 11: 21 AM Page 10 I7A300 NOV 19, 2019 11:21 AM I7A400 NOV 19, 2019 11: 21 AM I7A500 NOV 19, 2019 11:21 AM I7A600 NOV 19, 2019 11: 21 AM I7A700 NOV 19, 2019 11:21 AM I7A800 NOV 19, 2019 11:21 AM I7A900 NOV 19, 2019 11:21 AM 9999FF1B I7AC00 NOV 19, 2019 11:21 AM I7AD00 NOV 19, 2019 11: 21 AM I7AE00 NOV 19, 2019 11: 21 AM I7AF00 NOV 19, 2019 11: 21 AM I7B100 ~8¥Li~/; 2019 11: 21 AM POSITION -METER -TANK BUS SLOT FUEL_P METER TANK ------------------------------- TANK MAP EMPTY I7B200 NOV 19, 2019 11: 21 AM METER CALIBRATION OFFSET: 0, 000% I7B400 NOV 19, 2019 11: 21 AM I7BC00 NOV 19, 2019 11: 21 AM I7BD00 NOV 19, 2019 11:21 AM PRESSURE LLD SETUP REPORT Q 1: 87 UNLEADED IN-TANK ALARMS T l:HIGH WATER ALARM T 1: LOW PRODUCT ALARM LtQ~f ~u~[N~eMLMS L 2 : FUEL ALARM L 3: FUEL ALARM L 4: FUEL ALARM L 5: FUEL ALARM L 6: FUEL ALARM L 7: FUEL ALARM L 8; FUEL ALARM L 9: FUEL ALARM LlO: FUEL ALARM Lll: FUEL ALARM L22: FUEL ALARM L23; FUEL ALARM L 1: SENSOR OUT ALARM L 2: SENSOR OUT ALARM L 3: SENSOR OUT ALARM L 4: SENSOR OUT ALARM L 5 : SENSOR OUT ALARM L 6: SENSOR OUT ALARM L 7; SENSOR OUT ALARM L 8; SENSOR OUT ALARM L 9: SENSOR OUT ALARM LlO: SENSOR OUT ALARM Lll: SENSOR OUT ALARM L22: SENSOR OUT ALARM L23: SENSOR OUT ALARM L 1: SHORT ALARM L 2 : SHORT ALARM L 3: SHORT ALARM L 4: SHORT ALARM L 5: SHORT ALARM L 6: SHORT ALARM L 7: SHORT ALARM L 8: SHORT ALARM L 9: SHORT ALARM LlO: SHORT ALARM Lll: SHORT ALARM Ll2: SHORT ALARM L22: SHORT ALARM L23: SHORT ALARM t1i \ t6~H Li~8~5D At~~~M L 2 : LOW LIQUID ALARM L 3: LOW LIQUID ALARM L 4: LOW LIQUID ALARM L 5: LOW LIQUID ALARM system Setup MAP L 6: LOW LIQUID ALARM L 7: LOW LIQUID ALARM Lll: LOW LIQUID ALARM Ll2 : LOW LIQUID ALARM PRESSURE LINE LEAK Q 1: PLLD OPEN ALARM SMARTSENSOR ALARMS slO: FUEL ALARM s 9: HIGH LIQUID ALARM slO: HIGH LIQUID ALARM ~1§: ~/iGM/i8~I~L!~tiRM slO:NO VACUUM ALARM sll: NO VACUUM ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPDR LEAK FAIL ISD VP PRES FAIL ISD VP STATUS FAIL ISD HOSE ALARMS ALL: FLOW COLLECT FAIL Q 2:91 UNLEADED IN-TANK ALARMS T 2: HIGH WATER ALARM T 2 : LOW PRODUCT ALARM LIQUID SENSOR ALMS L 1: FUEL ALARM L 2: FUEL ALARM L 3: FUEL ALARM L 4: FUEL ALARM L 5 : FUEL ALARM L 6: FUEL ALARM L 7: FUEL ALARM L13: FUEL ALARM Ll4: FUEL ALARM LlS: FUEL ALARM Ll6: FUEL ALARM Ll7: FUEL ALARM L22: FUEL ALARM L23: FUEL ALARM L 1: SENSOR OUT ALARM L 2: SENSOR OUT ALARM L 3: SENSOR OUT ALARM L 4: SENSOR OUT ALARM L 5: SENSOR OUT ALARM L 6: SENSOR OUT ALARM L 7: SENSOR OUT ALARM L13: SENSOR OUT ALARM Ll4: SENSOR OUT ALARM LlS : SENSOR OUT ALARM Ll6: SENSOR OUT ALARM L17: SENSOR OUT ALARM L22: SENSOR OUT ALARM L23: SENSOR OUT ALARM L l: SHORT ALARM L 2: SHORT ALARM L 3: SHORT ALARM L 4: SHORT ALARM L 5 : SHORT ALARM L 6: SHORT ALARM L 7: SHORT ALARM L13: SHORT ALARM Ll4: SHORT ALARM LlS: SHORT ALARM Ll6: SHORT ALARM Ll7: SHORT ALARM L22: SHORT ALARM L23: SHORT ALARM t1n6~HLi/;8~6D At~~~M L 2: LOW LIQUID ALARM L 3: LOW LIQUID ALARM L 4: LOW LIQUID ALARM L 5 : LOW LIQUID ALARM L 6: LOW LIQUID ALARM L 7: LOW LIQUID ALARM Ll7: LOW LIQUID ALARM PRESSURE LINE LEAK Q 2 : PLLD OPEN ALARM SMARTSENSOR ALARMS slO: FUEL ALARM sl2: FUEL ALARM s13: FUEL ALARM slO: HIGH LIQUID ALARM sl2: HIGH LIQUID ALARM m: ~liGMlia~1~L!~tiRM s13 :NO VACUUM ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD VP PRES FAIL ISD VP STATUS FAIL ISO HOSE ALARMS ALL: FLOW COLLECT FAIL Q 3 :DIESEL IN-TANK ALARMS T 3: HIGH WATER ALARM T 3: LOW PRODUCT ALARM LIQUID SENSOR ALMS L 1: FUEL ALARM L 2 FUEL ALARM L 3 FUEL ALARM L 4 FUEL ALARM Ll7 FUEL ALARM Ll8 FUEL ALARM Ll9 FUEL ALARM L20 FUEL ALARM L21 FUEL ALARM L22 FUEL ALARM L23 FUEL ALARM L 1 SENSOR OUT ALARM L 2 SENSOR OUT ALARM L 3 SENSOR OUT ALARM L 4 SENSOR OUT ALARM Ll7 SENSOR OUT ALARM Ll8 SENSOR OUT ALARM Ll9 SENSOR OUT ALARM L20 SENSOR OUT ALARM L21 SENSOR OUT ALARM L22 SENSOR OUT ALARM Page 11 L23: SENSOR OUT ALARM L 1: SHORT ALARM L 2 : SHORT ALARM L 3: SHORT ALARM L 4: SHORT ALARM Ll7: SHORT ALARM Ll8: SHORT ALARM L19: SHORT ALARM L20: SHORT ALARM L21: SHORT ALARM L22: SHORT ALARM L23: SHORT ALARM Ll7: HIGH LIQUID ALARM L 1: LOW LIQUID ALARM L 2: LOW LIQUID ALARM L 3: LOW LIQUID ALARM L 4: LOW LIQUID ALARM Ll7: LOW LIQUID ALARM PRESSURE LINE LEAK Q 3: PLLD OPEN ALARM SMARTSENSOR ALARMS sl4: FUEL ALARM sl7: FUEL ALARM sl4: HIGH LIQUID ALARM sl7: HIGH LIQUID ALARM sl4: NO VACUUM ALARM sl7: NO VACUUM ALARM I7BE00 NOV 19, 2019 11:22 AM I7C400 NOV 19, 2019 11: 22 AM I7C500 NOV 19, 2019 11: 22 AM I7C600 NOV 19, 2019 11:22 AM I7c700 NOV 19, 2019 11: 22 AM I7C800 NOV 19, 2019 11:22 AM I7C900 NOV 19, 2019 11: 22 AM 180100 NOV 19, 2019 11:22 AM EXTERNAL INPUT CONFIGURATION DEVICE LABEL 1 EMERGENCY SHUT OFF 2 !80200 NOV 19, 2019 11:22 AM EXTERNAL INPUT LABEL DEVICE LABEL 1 EMERGENCY SHUT OFF 2 180300 NOV 19, 2019 11: 22 AM EXTERNAL INPUT TYPE INPUT NAME 1 EMERGENCY SHUT OFF 2 180400 NOV 19, 2019 11:22 AM 180600 NOV 19, 2019 11:22 AM RELAY CONFIGURATION DEVICE LABEL 1 OVERFILL 2 180700 NOV 19, 2019 11:22 AM RELAY LABEL DEVICE LABEL 1 OVERFILL 2 180800 NOV 19, 2019 11: 22 AM RELAY SETUP REPORT R l:OVERFILL TYPE: STANDARD NORMALLY OPEN TANK #: NONE IN-TANK ALARMS ALL: OVERFILL ALARM ALL: HIGH PRODUCT ALARM system Setup CONFIGURED ON OFF TYPE STANDARD STANDARD CONFIGURED ON OFF ORIENTATION NORMALLY OPEN NORMALLY OPEN TANK# R 2: TYPE: STANDARD NORMALLY OPEN TANK #: NONE -NO ALARM ASSIGNMENTS - !80900 NOV 19, 2019 11:22 AM RELAY ORIENTATION RELAi g~mmION 2 I80A00 NOV 19, 2019 11: 22 AM RELAY TYPE RELAY DESIGNATION ½ OVERFILL I80B00 NOV 19, 2019 11: 22 AM RELAY TANK ASSIGNMENT RELAY DESIGNATION ½ OVERFILL I80C00 NOV 19, 2019 11: 22 AM EXTERNAL INPUT TYPE INPUT NAME 1 EMERGENCY SHUT OFF 2 !85100 NOV 19, 2019 11:22 AM RESTORE SETUP DATA: DISABLED !85200 NOV 19, 2019 11: 22 AM SAVE SETUP DATA: DISABLED !85300 NOV 19, 2019 11:22 AM CLEAR SETUP DATA: DISABLED !88100 NOV 19, 2019 11: 22 AM !88200 NOV 19, 2019 11:22 AM !88500 NOV 19, 2019 11: 22 AM 188600 NOV 19, 2019 11:22 AM !88700 NOV 19, 2019 11: 22 AM !88800 ~~l~6A~gl9 ,in~D~~: ) CONNECTION : NONE c~Mg~rnN ~o~~-SAT ) cg~Mg~~gN ~o~~s-485) cg~Mg~~gN ~o~~s-232) !88900 NOV 19, 2019 11:22 AM I88D00 NOV 19, 2019 11:22 AM !89100 NOV 19, 2019 11: 22 AM I8A200 NOV 19, 2019 11:22 AM FOODS CO, 384 2501 HALEY BAKERSFIELD CA, 661-873-9343 SERVICE CODE LIST STANDARD LABEL REPROGRAMMED TLS CODE 0101 ORIENTATION NORMALLY OPEN NORMALLY OPEN TYPE STANDARD STANDARD TANK NONE NONE TYPE STANDARD STANDARD ORIENTATION NORMALLY OPEN NORMALLY OPEN TANK# Page 12 COLD BOOT SYSTEM 0102 REPLACED PC BOARD 0103 NO PROBLEM FOUND 0104 ~~H~~L~6c8M~UND 818~ REPLACED KEYBOARD 0107 REPLACED DISPLAY 0108 SYSTEM UPGRADE 0109 CONDUCTED TRAINING 0110 OPERATOR ERROR 0111 INSTALLED PAPER 0201 REPLACED PRINTER 0202 NEW LINE SHARE DEV 0203 CLEARED PAPER JAM 0204 ~~~m~o~A~~N~AH~T gm RECONNECTED PROBE 0303 mL~~og/~egh mi CLEANED PROBE 0306 CORRECT TANK CHART 0307 RESET ACCUCHART 0308 REPLACED SENSOR 0401 REWIRED SENSOR 0402 REMOVED FUEL 0403 REMOVED WATER 0404 ADJUSTED BRINE LVL 0405 REPAIRED PRIMARY LK 0406 REPAIRED SEC LK 0407 RECHARGED VACUUM 0408 REPLACED VAC TUBING 0409 ADDED COMM BOARD 0501 RESET MODEM 0502 RECONNECT PHONE LN 0503 NEW PHONE NUMBER 0504 NEW IP ADDRESS 0505 REPLACED COMM CABLE 0506 REPLACED DIM MODULE 0601 REPLACED DIM CABLE 0602 DIM MISAPPLICATION 0603 CAB RUN MODE 0604 REPAIRED LEAK 0701 REPAIRED STP CAP 0702 RESTORE STP POWER 0703 CLEAN FUNC ELEMENT 0704 DISBLE FUNC ELEMENT 0705 OUT OF FUEL 0706 REPL LLD TRANSDUCER 0707 REWIRED LLD 0708 REPLACED LLD MODULE 0709 REPLACED CHECK VLV 0710 REPLACE PRODUCT RL Y 0711 REPLACE DISP VALVE 0712 ELIM WPLLD NOISE 0713 INSTALL MECH LLD 0714 PERFORM LINE TEST 0715 REPLACED MLLD 0716 INSTALL NEW STP 0801 REPLACED UMP 0802 REPL FUNC ELEMENT 0803 REPL CHECK VALVE 0804 PMP NEW IP ADDRESS 0805 REPL CONTROL BOX 0806 REPLACED CAPACITOR 0807 REPLACED SEALS 0808 REPL VAR SPD CNTRL 0809 REWIRED PUMP 0810 REPL VLLD CONTROL 0901 REPL VLLD CHECK VLV 0902 VLLD SELF CHECK 0903 VLLD PUMP SELF TST 0904 VLLD OTHER ACTION 0905 CAL VAC ASSIST PUMP 1001 ~~~~u~mse,~ HH rm 2 IN DECAY TEST 1004 10 IN DECAY TEST 1005 REPAIRED CONT LEAK 1006 RPR VAC ASSIST PUMP 1007 REPL VAC ASSIST PMP 1008 ~elu~;lJ8lt~oCESSOR 18~6 RPR SPILL BUCKET 1101 RPR DELIVERY CAP 1102 RPR VPR EXTR CAP 1103 RPR PROBE RISER CAP 1104 REPLACED FILTER 1201 REPL DISPENSER SW 1202 COLD BOOT SYSTEM 1203 REPAIRED DISPENSER 1204 RESET SHEAR VALVE 1205 REPL SHEAR VALVE 1206 REPAIRED PIPING 1207 REPAIRED BOOT 1208 CALIB LIQUID MTR 1209 REPL DISPENSER PRTR 1210 INSTALLED PAPER 1211 CLEARED PAPER JAM 1212 REPAIRED DOOR LOCK 1213 REPAIRED DOOR SW 1214 REPL HANGING HW 1301 REPLACED NOZZLE 1302 REPLACED BOOT 1303 REPLACED SPOUT 1304 REPL PRIMARY HOSE 1305 REPLACED BREAKAWAY 1306 REPAIRED BREAKAWAY 1307 REPLACED WHIP HOSE 1308 REPL HOSE EXTRACTOR 1309 REPL FLOW LIMITER 1310 REPL NOZZLE COVER 1311 BAGGED OFF NOZZLE 1312 RETURNED NOZZLE 1313 REPROGRAMMED POS 1401 REPL POS SOFTWARE 1402 COLD BOOT SYSTEM 1403 REPLACED POS 1404 REWIRED POS 1405 RPR OUTSIDE LIGHTS 1501 REPAIRED SIGNAGE 1502 CLEANED STORM DRAIN 1503 SVC OIL VfTR SEPRATR 1504 ANN OPERABILITY TST 1601 WEIGHT MEASURES TST 1602 SUMP INTEGRITY TST 1603 OPERATOR VISIT 1604 ELD TEST 1605 SPILL BUCKET TEST 1606 USER DEFINED LABEL CODE NONE I8A300 NOV 19, 2019 11:23 AM I8A400 NOV 19, 2019 11: 23 AM I8BC00 NOV 19, 2019 11:23 AM RELAY SETUP REPORT R !:OVERFILL system setup TYPE: STANDARD NORMALLY OPEN TANK #: NONE IN-TANK ALARMS ALL:OVERFILL ALARM ALL: HIGH PRODUCT ALARM R 2: TYPE: STANDARD NORMALLY OPEN TANK #: NONE NO ALARM ASSIGNMENTS - I8Cl00 NOV 19, 2019 11:23 AM I8C200 NOV 19, 2019 11: 23 AM 9999FF1B 9999FF1B 190100 NOV 19, 2019 11:23 AM SYSTEM BOARD 190200 I/0 PASS NOV 19, 2019 11:23 AM SOFfWARE REVISION LEVEL VERSION 330. 01 SOFTivARE# 346330-100-B CREATED -10.07,23.17.25 S-MODULE# 330160-104-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS BIR ISD 190300 NOV 19, 2019 11:23 AM PC DIAGNOSTIC DATA PERIPHERAL CONTROLLER PC SWARE# 330269-002-B CREATED -94.12.16.13.26 PC ROM CHECKSUM PASSED PC RESET COUNTS = 154 PC COMM ERRORS = 167 MC CKSUM ERRS = 23 MC->PC COMMS =3476133314 MC<-PC COMMS =3476148795 190500 NOV 19, 2019 11:23 AM SOFTWARE REVISION LEVEL VERSION 330. 01 SOFTWARE# 346330-100-B CREATED -10.07.23.17.25 S-MODULE# 330160-104-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS BIR ISD IAOlOO NOV 19, 2019 11: 23 AM TANK 1 Un 1 eaded m~ ~ m~~~m RAM PASS TYPE MAG MAG MAG PROM PASS CODE D004 D004 D004 LENGTH 126.00 126.00 126.00 sEmh~o. 551174 551172 Page 13 System Setup Bel shire TLS PO ll er DO ALARM HISTORY Command set ver 5 .12 Started at 11/19/2019 11:50:01 AM !10200 NOV 19, 2019 11:49 AM FOODS CO, 384 2501 HALEY BAKERSFIELD CA, 661-873-9343 SYSTEM CONFIGURATION SLOT 1 2 I 6 7 8 9 10 11 12 13 14 15 16 BOARD TYPE 4 PROBE / G.T. PLLD SENSOR BO INTERSTITIAL BO INTERSTITIAL BO INTERSTITIAL BO 8SMARTSENSOR BO 7SMARTSENSOR BO 8SMARTSiNSOR BO COMBO I O BOARD PLLD PO ER BO UNUSED UNUSED UNUSED UNUSED UNUSED UNUSED COMM 1 ELEC DISP INT, COMM 2 SERIAL SAT BO COMM 3 UNUSED COMM 4 UNUSED COMM 5 RS485 SERIAL BO COMM 6 RS232 SERIAL BO 120600 NOV 19, 2019 11: 49 AM FOODS CO, 384 2501 HALEY BAKERSFIELD CA, 661-873-9343 TANK ALARM HISTORY TANK 1 Unleaded OVERFILL ALARM LOW PRODUCT ALARM SUDDEN LOSS ALARM HIGH PRODUCT ALARM INVALID FUEL LEVEL PROBE OUT HIGH WATER WARNING DELIVERY NEEDED LOW TEMP WARNING TANK Premuim OVERFILL ALARM LOW PRODUCT ALARM SUDDEN LOSS ALARM HIGH PRODUCT ALARM INVALID FUEL LEVEL PROBE OUT HIGH WATER WARNING DELIVERY NEEDED LOW TEMP WARNING TANK 3 Diesel OVERFILL ALARM LOW PRODUCT ALARM SUDDEN LOSS ALARM POWER ON RESET 164807 NOV 19, AUG 9, JUL 28, SEP ~j: DEC DEC NOV 19, NOV 27, NOV 28, NOV 19, DEC 3' DEC 4, DEC 15, NOV 19, NOV 1~: JUL NOV 27, NOV 27, SEP 21, AUG 20, NOV 19, NOV 28, DEC 5. NOV H: NOV SEP 21, DEC it DEC DEC NOV 27, NOV 27, DEC 4, DEC §: DEC DEC 6, DEC ~: DEC DEC 6, NOV 19, NOV 27, NOV 27, NOV H: DEC H: DEC MAR SEP 29, NOV 19, SEP 21, NOV 28, NOV H: NOV SEP 21, SEP 21, DEC ~: DEC NOV 19, NOV 27, 3919 202970 203082 203127 39544 514845 9949365 9928 102072 9852763 9870287 9798228 9823814 9765830 9798012 101521 9786178 9767641 9753587 68839 15029 2019 11:21 AM 2019 12:43 AM 2019 3: 10 PM 2015 5: 51 PM 2014 7: 57 AM 2010 3: 26 PM 2019 11:12 AM 2018 10:29 AM 2017 10:22 AM 2019 11: 20 AM 2015 9:23 AM 2014 8:16 AM 2010 2: 55 PM 2019 11:21 AM 2019 11:12 AM 2019 8: 25 PM 2018 3: 36 PM 2018 10: 30 AM 2018 8:03 AM 2018 11:43 AM 2019 11: 22 AM 2017 10: 30 AM 2016 9:05 AM 2019 11:23 AM 2018 10:25 AM 2018 8:15 AM 2015 9: 41 AM 2012 2: 35 PM 2010 3: 26 PM 2018 3 :40 PM 2018 10:22 AM 2014 7: 55 AM 2016 9:20 AM 2015 9:42 AM 2011 11:29 AM 2015 9: 46 AM 2013 10: 35 AM 2011 11: 31 AM 2019 11: 23 AM 2018 3:40 PM 2018 10: 26 AM 2017 10: 24 AM 2010 1:01 PM 2018 10:02 PM 2018 11: 30 AM 2017 7: 17 PM 2019 11:24 AM 2018 8: 23 AM 2017 10: 33 AM 2019 11:25 AM 2018 10:13 AM 2018 8:24 AM 2018 7: 59 AM 2015 9: 59 AM 2015 9:55 AM 2019 11:16 AM 2018 10:11 AM CURRENT 163215 3922 201176 201686 201431 39392 509850 39481 9942 101796 8413409 8398860 8399103 8404004 8406896 8403783 101095 485954 8402525 8408574 68704 15013 Page 1 Alarm HIGH PRODUCT ALARM INVALID FUEL LEVEL PROBE OUT HIGH WATER WARNING DELIVERY NEEDED MAX PRODUCT ALARM LOW TEMP WARNING 130200 NOV 19, 2019 11:49 AM FOODS CO. 384 2501 HALEY BAKERSFIELD CA, 661-873-9343 LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 DISP 1-2 DUAL NOV 19, 2019 10: 29 AM NOV 19, 2019 9: 5 8 AM NOV 19, 2019 9:58 AM DISP 3-4 DUAL NOV 19, 2019 10: 30 AM NOV 19, 2019 10: 04 AM NOV 19, 2019 10: 04 AM DISP 5-6 DUAL NOV 19, 2019 10: 30 AM NOV 19, 2019 10: 08 AM NOV 19, 2019 10: 07 AM 4 DISP 7-8 DUAL NOV 19, 2019 10: 30 AM NOV 19, 2019 10: 18 AM NOV 19, 2019 10: 17 AM DISP 9-10 DUAL NOV 19, 2019 10: 29 AM NOV 19, 2019 10: 01 AM NOV 19, 2019 9:59 AM 6 DISP 11-12 DUAL NOV 19, 2019 10: 29 AM NOV 19, 2019 10: 11 AM ~~¥r1h-r211lule: 11 AM 7 NOV 19, 2019 10:30 AM NOV 19, 2019 10: 14 AM ~9\G~BI~~19 10: 13 AM 8 NOV 19, 2019 10: 29 AM NOV 19, 2019 9:38 AM NOV 19, 2019 9:38 AM 9 87 TURBINE BRINE NOV 19, 2019 10:29 AM NOV 19, 2019 9: 36 AM NOV 27, 2018 1:48 PM 10 87 FILL NOV 19, 2019 10:30 AM NOV 19, 2019 9:36 AM NOV 19, 2019 9: 35 AM 11 87 FILL BRINE NOV 19, 2019 10: 29 AM NOV 19, 2019 9:34 AM NOV 27, 2018 1:48 PM 12 87 ANNULAR NOV 19, 2019 10: 30 AM NOV 19, 2019 9:33 AM ~~\G~liI~~19 9: 33 AM 13 NOV 19, 2019 10:29 AM NOV 19, 2019 9:46 AM NOV 19, 2019 9:45 AM 14 91 TURBINE BRINE NOV 19, 2019 10: 29 AM NOV 19, 2019 9 :44 AM NOV 27, 2018 1:48 PM 15 91 FILL NOV 19, 2019 10: 30 AM NOV 19, 2019 9:43 AM NOV 19, 2019 9:43 AM 16 91 FILL BRINE NOV 19, 2019 10: 30 AM NOV 19, 2019 9:42 AM NOV 27, 2018 1:48 PM 17 91 DIESEL ANNULAR NOV 19, 2019 10: 30 AM NOV 19, 2019 9:41 AM 18 NOV 19, 2019 9:41 AM DIESEL TURBINE NOV 19, 2019 10: 30 AM NOV 19, 2019 9:51 AM NOV 19, 2019 9:51 AM 19 DIESEL TURBINE BRINE NOV 19, 2019 10: 30 AM NOV 19, 2019 9:50 AM JUN 21, 2019 8:42 AM 20 DIESEL FILL NOV 19, 2019 10:30 AM ~gt l:§: ~m 9:49 AM 9:49 AM 21 DIESEL FILL BRINE NOV 19, 2019 10: 30 AM NOV 19, 2019 9:48 AM NOV 27, 2018 1:48 PM 22 VENT SUMP NOV 19, 2019 10: 30 AM Hi story SEP 21, 2018 7: 59 AM DEC 2~: 2011 11: 58 AM DEC 2010 1: 31 PM NOV 28, 2017 10: 36 AM DEC 5' 2016 9: 36 AM DEC 3' 2015 9: 59 AM NOV H: 2019 11:25 AM NOV 2019 11:18 AM NOV 19, 2019 11:17 AM DEC 4, 2014 8:04 AM NOV 27, 2018 10:11 AM SEP 21, 2018 7: 59 AM NOV 28, 2017 10: 37 AM DEC 27, 2010 1:31 PM NOV 19, 2019 11:26 AM NOV 27, 2018 10:14 AM SEP 21, 2018 8: 28 AM SENSOR OUT ALARM SENSOR OUT ALARM FUEL ALARM SENSOR OUT ALARM LOW LIQUID ALARM SENSOR OUT ALARM SENSOR OUT ALARM LOW LIQUID ALARM SENSOR OUT ALARM SENSOR OUT ALARM LOW LIQUID ALARM SENSOR OUT ALARM SENSOR OUT ALARM LOW LIQUID ALARM FUEL ALARM SENSOR OUT ALARM LOW LIQUID ALARM SENSOR OUT ALARM SENSOR OUT ALARM LOW LIQUID ALARM SENSOR OUT ALARM SENSOR OUT ALARM SENSOR OUT ALARM FUEL ALARM SENSOR OUT ALARM FUEL ALARM SENSOR OUT ALARM SENSOR OUT ALARM SENSOR OUT ALARM FUEL ALARM SENSOR OUT ALARM FUEL ALARM SENSOR OUT ALARM SENSOR OUT ALARM ~6~\~i8~5D At~;~M SENSOR OUT ALARM SENSOR OUT ALARM FUEL ALARM SENSOR OUT ALARM FUEL ALARM SENSOR OUT ALARM SENSOR OUT ALARM SENSOR OUT ALARM FUEL ALARM SENSOR OUT ALARM FUEL ALARM SENSOR OUT ALARM SENSOR OUT ALARM LOW LIQUID ALARM HIGH LIQUID ALARM SENSOR OUT ALARM SENSOR OUT ALARM FUEL ALARM SENSOR OUT ALARM FUEL ALARM SENSOR OUT ALARM SENSOR OUT ALARM SENSOR OUT ALARM FUEL ALARM SENSOR OUT ALARM FUEL ALARM SENSOR OUT ALARM SENSOR OUT ALARM ~g~ H: mi m~ ~ 2 3 VENT SUMP BRINE ~g~ l:§: mi 1~: ~~ ~ JUN 21, 2019 8:42 AM I30700 NOV 19, 2019 11: 49 AM I31600 NOV 19, 2019 11:49 AM FOODS CO. 384 2501 HALEY BAKERSFIELD CA. 661-873-9343 SMART SENSOR ALARM HISTORY REPORT SENSOR LOCATION 1 DISP 1-2 VFM DEC 15, 2010 3:59 PM DISP 3-4 VFM DISP 5-6 VFM DEC 15, 2010 3: 59 PM 4 DISP 7-8 VFM DEC 15, 2010 3: 26 PM DISP 9-10 VFM 6 mr11d~1eFM3 = 25 PM mp lh-I~1eFM 3 = 2 6 PM 7 mlh-i~1~s 3 '26 PM 8 DEC 6, 2011 10: 34 AM DEC 15, 2010 3: 26 PM 9 87 PRODUCT ~g~ l:§: mi im ~ NOV 11, 2019 10: 21 PM 10 87 91 VAPOR ~g~ i:i• mi u~ ~ ~9vv~~Um?o:29 AM 11 ~g~ H· mi u~ ~ NOV 27: 2018 10: 29 AM 12 91 PRODUCT NOV 19, 2019 9:46 AM NOV 27, 2018 10:22 AM 13 NOV 28, 2017 9:02 AM 91 VENT-CHASE ~g~ H· ~m u~ AM AM NOV 27: 2018 10:22 AM 14 DIESEL PRODUCT ~g~ H· ~81§ u~ AM AM NOV 27: 2018 10:07 AM 15 PMC CANISTER :~~ H: ~m nr ~ ~~~ ~4, 2018 9:01 PM 16 17 DIESEL VENT-CHASE NOV 19, 2019 9:52 AM NOV 19, 2019 9:51 AM NOV 27, 2018 10: 07 AM I32300 NOV 19, 2019 11:49 AM !34200 NOV 19, 2019 11:49 AM I34700 NOV 19, 2019 11:49 AM I34C00 NOV 19, 2019 11:49 AM 120700 NOV 19, 2019 11:49 AM FOODS CO. 384 2501 HALEY BAKERSFIELD CA. 661-873-9343 TANK LEAK TEST HISTORY T l:Unleaded LAST GROSS TEST PASSED: NO TEST PASSED LAST ANNUAL TEST PASSED: NO TEST PASSED FULLEST ANNUAL TEST PASS NO TEST PASSED LAST PERIODIC TEST PASS: NO TEST PASSED FULLEST PERIODIC TEST PASSED EACH MONTH: TEST START TIME TANK LEAK TEST HISTORY T 2:Premuim LAST GROSS TEST PASSED: NO TEST PASSED HOURS SENSOR OUT ALARM FUEL ALARM SENSOR OUT ALARM FUEL ALARM SENSOR OUT ALARM COMMUNICATION ALARM COMMUNICATION ALARM COMMUNICATION ALARM COMMUNICATION ALARM COMMUNICATION ALARM COMMUNICATION ALARM COMMUNICATION ALARM COMMUNICATION ALARM ~6G~A~58W2L!kt,RM VACUUM WARNING ~6G~A~58W2L!kt,RM HIGH LIQUID ALARM ~6GM58~12L!kt,RM HIGH LIQUID ALARM NO VACUUM ALARM HIGH LIQUID ALARM HIGH LIQUID ALARM HIGH LIQUID ALARM ND VACUUM ALARM HIGH LIQUID ALARM ~6GM58W2L!~t,RM HIGH LIQUID ALARM COMMUNICATION ALARM COMMUNICATION ALARM SENSOR FAULT ALARM HIGH LIQUID ALARM NO VACUUM ALARM HIGH LIQUID ALARM VOLUME % VOLUME TEST TYPE Page 2 LAST ANNUAL TEST PASSED: NO TEST PASSED FULLEST ANNUAL TEST PASS NO TEST PASSED LAST PERIODIC TEST PASS: NO TEST PASSED FULLEST PERIODIC TEST PASSED EACH MONTH: TEST START TIME HOURS VOLUME % VOLUME TEST TYPE TANK LEAK TEST HISTORY T 3:Diesel LAST GROSS TEST PASSED: NO TEST PASSED LAST ANNUAL TEST PASSED: NO TEST PASSED FULLEST ANNUAL TEST PASS NO TEST PASSED LAST PERIODIC TEST PASS: NO TEST PASSED FULLEST PERIODIC TEST PASSED EACH MONTH: TEST START TIME HOURS VOLUME % VOLUME TEST TYPE 131200 NOV 19, 2019 11:49 AM !38200 NOV 19, 2019 11:49 AM FOODS CO. 384 2501 HALEY BAKERSFIELD CA. 661-873-9343 PRESSURE LINE LEAK ALARM HISTORY REPORT Q 1: 87 UNLEADED NOV 19, 2019 11:07 AM NOV 19, 2019 11: 00 AM NOV 19, 2019 10: 29 AM NOV 19, 2019 10:18 AM NOV 19, 2019 10: 17 AM NOV 19, 2019 10: 17 AM NOV 19, 2019 10: 16 AM NOV H: m§ l:8:l:1 AM NOV AM NOV 19, 2019 10:13 AM Q 2: 91 UNLEADED NOV 19, 2019 10: 49 AM NOV 19, 2019 10:49 AM NOV 19, 2019 10:29 AM NOV 19, 2019 10: 18 AM NOV 19, 2019 10:17 AM NOV 19, 2019 10: 17 AM NOV 19, 2019 10: 16 AM NOV 19, 2019 10: 14 AM NOV 19, 2019 10: 13 AM NOV 19, 2019 10: 13 AM Q 3 :DIESEL NOV 19, 2019 10:45 AM NOV 19, 2019 10:45 AM NOV 19, 2019 10:29 AM NOV 19, 2019 10:18 AM NOV 19, 2019 10: 17 AM NOV 19, 2019 10:17 AM NOV 19, 2019 10:16 AM NOV 19, 2019 10:08 AM NOV 19, 2019 10:07 AM NOV 19, 2019 10: 06 AM I38700 NOV 19, 2019 11:49 AM I40200 NOV 19, 2019 11:49 AM FOODS CO. 384 2501 HALEY BAKERSFIELD CA. 661-873-9343 INPUT LOCATION 1 EMERGENCY SHUT OFF NOV 15, 2019 11: 16 AM NOV 12, 2019 9:41 PM OCT 30, 2019 10: 56 PM NOV 15, 2019 11: 20 AM NOV 12, 2019 9: 5 3 PM OCT 30, 2019 11: 15 PM 120300 NOV 19, 2019 11:49 AM FOODS CO. 384 2501 HALEY BAKERSFIELD CA. 661-873-9343 TANK 1 Unleaded TEST STATUS: OFF PLLD SHUTDOWN ALARM GROSS LINE FAIL PLLD SHUTDOWN ALARM PLLD SHUTDOWN ALARM PLLD SHUTDOWN ALARM PLLD SHUTDOWN ALARM PLLD SHUTDOWN ALARM PLLD SHUTDOWN ALARM PLLD SHUTDOWN ALARM PLLD SHUTDOWN ALARM PLLD SHUTDOWN ALARM GROSS LINE FAIL PLLD SHUTDOWN ALARM PLLD SHUTDOWN ALARM PLLD SHUTDOWN ALARM PLLD SHUTDOWN ALARM PLLD SHUTDOWN ALARM PLLD SHUTDOWN ALARM PLLD SHUTDOWN ALARM PLLD SHUTDOWN ALARM PLLD SHUTDOWN ALARM GROSS LINE FAIL PLLD SHUTDOWN ALARM PLLD SHUTDOWN ALARM PLLD SHUTDOWN ALARM PLLD PLLD PLLD PLLD PLLD SHUTDOWN ALARM SHUTDOWN ALARM SHUTDOWN ALARM SHUTDOWN ALARM SHUTDOWN ALARM EXTERN INPUT ALARM EXTERN INPUT ALARM EXTERN INPUT ALARM EXTERN INPUT NORMAL EXTERN INPUT NORMAL EXTERN INPUT NORMAL LEAK DATA NOT AVAILABLE ON THIS TANK Alarm History TANK 2 Premuim TEST STATUS: OFF LEAK DATA NDT AVAILABLE ON THIS TANK TANK 3 Diesel TEST STATUS: OFF LEAK DATA NOT AVAILABLE ON THIS TANK I25100 NOV 19, 2019 11:49 AM FOODS CO. 384 2501 HALEY BAKERSFIELD CA. 661-873-9343 CSLD TEST RESULTS TANK PRODUCT 200 FOODS CO. 384 2501 HALEY BAKERSFIELD CA, 661-873-9343 RESULT NOV 19, 2019 11:49 AM TANK PRODUCT GALLONS INCHES WATER DEG F ULLAGE 1 2 3 210 FOODS CO. 384 2501 HALEY BAKERSFIELD CA. 661-873-9343 TANK 1 Unleaded TEST STATUS: OFF 16649 6918 3196 LEAK DATA NOT AVAILABLE ON THIS TANK TANK 2 Premuim TEST STATUS: OFF LEAK DATA NOT AVAILABLE ON THIS TANK TANK 3 Diesel TEST STATUS: OFF LEAK DATA NOT AVAILABLE ON THIS TANK I21300 NOV 19, 2019 11: 49 AM FOODS CO, 384 2501 HALEY BAKERSFIELD CA, 661-873-9343 DELIVERY REPORT T l:Unleaded 92.19 96. 81 42. 05 0.0 0.0 0.0 72 .3 71.8 77 .4 3133 983 7224 INCREASE DATE / TIME GALLONS TC GALLONS WATER TEMP DEG F HEIGHT 106. 4lND: NOV 19, 2019 11: 27 AM lOlJ°/jART: NOV 19, 2019 11:20 AM AMOUNT: 98 _82 END: NOV 19, 2019 3:13 AM 68 _2~TART: NOV 19, 2019 2:51 AM AMOUNT: 96 _58 END: NOV 18, 2019 1:28 AM 57 _3~TART: NOV 18, 2019 1:00 AM AMOUNT: 89 _49 END: NOV 16, 2019 5:22 PM 63.8HTART: NOV 16, 2019 4:59 PM AMOUNT: 90 _05 END: NOV 15, 2019 7:27 PM 52.6ITART: NOV 15, 2019 7:08 PM AMOUNT: 89 _88 END: NOV 14, 2019 4:01 PM 53,0~TART: NOV 14, 2019 3:36 PM AMOUNT: 98_57 END: NOV 13, 2019 7:34 AM 63 , 3~TART: NOV 13, 2019 7: 13 AM AMOUNT: 98_72 END: NOV 11, 2019 4:44 PM 59. 3~TART: NOV 11, 2019 4: 18 PM AMOUNT: 84_94 END: NOV 10, 2019 3:04 PM 18818 18149 669 17748 11871 5877 17393 9499 7894 16167 10926 5241 16269 8456 7813 16238 8554 7684 17709 10809 6900 17732 9932 7800 15311 18678 o. 92 18017 0. 00 661 17595 0 .00 11759 0.00 5836 17238 0. 00 9398 0.00 7840 16004 0. 00 10819 0 .00 5185 16109 0.00 8359 0.00 7750 16056 0 .oo 8461 0.00 7595 17514 0.00 10672 o.oo 6842 17509 0.00 9812 0.00 7697 15131 0. 00 70.62 70.31 72. 26 73. 39 72.69 75 .16 74.32 73 .89 73. 99 76.43 75. 95 75. 52 75 .65 78.07 77 .95 77 .17 76. 72 Page 3 48 , 5§TART: NOV 10, 2019 2: 42 PM AMOUNT: 82 _92 END: NOV 9, 2019 10:16 AM 58 _36TART: NOV 9, 2019 9:56 AM AMOUNT: T 2:Premuim INCREASE DATE / TIME HEIGHT 105_66END: NOV 19, 2019 11:30 AM 93 . 2~TART: NOV 19, 2019 11: 22 AM AMOUNT: 98_ 50 END: NOV 19, 2019 3: 10 AM 59 _5~TART: NOV 19, 2019 2:53 AM AMOUNT: 71. 64 END: NOV 18, 2019 1: 29 AM 59 _5~TART: NOV 18, 2019 1:21 AM AMOUNT: END: NOV 16, 2019 5 :16 PM 74. 38 62.2ITART: NOV 16, 2019 5:06 PM AMOUNT: 73 _59 END: NOV 15, 2019 7:18 PM 61.4~TART: NOV 15, 2019 7:10 PM AMOUNT: 77 , 56 END: NOV 14, 2019 3: 42 PM 65.2HTART: NOV 14, 2019 3:32 PM AMOUNT: 84 _27 END: NOV 13, 2019 7:18 AM 60 _9~TART: NOV 13, 2019 7:07 AM AMOUNT: 75 _60 END: NOV 11, 2019 4:27 PM 63 _3§TART: NOV 11, 2019 4:17 PM AMOUNT: 75 _86 END: NOV 10, 2019 3:08 PM 63 _6~TART: NOV 10, 2019 2:58 PM AMOUNT: 80 _49 END: NOV 9, 2019 10:13 AM START: NOV 9, 2019 10: 03 AM 68.03 AMOUNT: T 3:Diesel INCREASE DATE / TIME HEIGHT 99 .0l END: NOV 19, 2019 11:32 AM 85 , 86TART: NOV 19, 2019 11: 24 AM AMOUNT: 48 _20 END: NOV 16, 2019 5:11 PM 29. 6HTART: NOV 16, 2019 4: 59 PM AMOUNT: 53. 31 END: NOV 9, 2019 10:12 AM 35 _5~TART: NOV 9, 2019 9:57 AM AMOUNT: 47 .02 END: NOV 6, 2019 3:16 AM 28 _2§TART: NOV 6, 2019 3:03 AM AMOUNT: 35 _31 END: NOV 4, 2019 1:32 PM 34 _86TART: NOV 4, 2019 1:23 PM AMOUNT: 35 _48 END: NOV 4, 2019 11:23 AM 34 _7~TART: NOV 4, 2019 11:16 AM AMOUNT: 48 _50 END: OCT 31, 2019 2:59 PM START: OCT 31, 2019 2:49 PM Al arm Hi story 7587 7724 14918 9704 5214 7502 0.00 7629 14751 0.00 9589 0.00 5162 GALLONS TC GALLONS WATER 7445 7394 0.89 6677 6633 0. 00 768 761 7028 3995 3033 5007 3994 1013 5232 4219 1013 5168 4156 1012 5490 4478 1012 6018 4112 1906 5332 4319 1013 5353 4342 1011 5724 4708 6970 0.00 3951 0.00 3019 4952 0.00 3948 0,00 1004 5176 0.00 4173 0.00 1003 5110 0.00 4108 0.00 1002 5430 0.00 4429 0.00 1001 5953 0.00 4062 0,00 1891 5269 0.00 4268 0.00 1001 5291 o.oo 4292 0.00 999 5658 0.00 4652 0.00 1016 1006 75. 83 75. 93 76.92 TEMP DEG F 69. 75 69.27 71. 53 75. 55 75. 58 76.10 75.23 75. 60 75. 85 76.18 75.23 75.48 75. 23 77 .26 76.63 76.84 76. 34 76.54 76. 25 76.96 GALLONS TC GALLONS WATER TEMP DEG F 9413 8209 9316 0.72 8125 0. 73 1204 1191 3896 1898 1998 4494 2492 2002 3760 1765 1995 2467 2413 54 2484 2405 79 3931 1942 3866 0.00 1882 0.00 1984 4462 0.00 2473 0.00 1989 3734 0.00 1749 0.00 1985 2444 0.00 2391 0.00 53 2462 0.00 2383 0.00 79 3894 0.00 1923 0.00 82 .80 82. 58 77 .14 77 .68 75. 38 76.67 75. 28 79. 28 80.01 79.99 79. 73 79. 73 80,81 80.67 30,13 11: 23AM AMOUNT: 1989 1971 T 1 TANK unleaded PROBE OUT CLEAR 11-19-19 11: 22AM END: OCT 26, 2019 6: 57 PM 3835 3795 0.00 82.56 47 .67 T 1 TANK Unleaded OVERFILL ALARM CLEAR 11-19-19 11:21AM START: OCT 26, 2019 6: 45 PM 1840 1822 0.00 81. 73 29.08 T 1 TANK Unleaded PROBE OUT ALARM 11-19-19 AMOUNT: 1995 1973 11: 21AM T 1 TANK Unleaded OVERFILL ALARM ALARM 11-19-19 END: OCT 22, 2019 4:36 PM 3700 3660 0.00 83, 99 11: 21AM 46, 50 START: 27, 62 OCT 22, 2019 4: 22 PM 1701 1686 T 3 TANK Diesel 0.00 79.41 11:19AM PROBE OUT CLEAR 11-19-19 AMOUNT: 1999 1974 T 3 TANK 11:18AM Diesel PROBE OUT ALARM 11-19-19 END: OCT 14, 2019 53 .28 3: 30 AM 4491 4455 0.00 77 .74 T 3 TANK Diesel 11:18AM PROBE OUT CLEAR 11-19-19 START: OCT 35. 55 14, 2019 3:18 AM 2492 2469 0.00 80.03 T 3 TANK Diesel SUDDEN LOSS ALARM CLEAR 11-19-19 11:18AM AMOUNT: 1999 1986 Q 3 OTHER DIESEL 11:17AM PLLD SHUTDOWN ALARM CLEAR 11-19-19 Q 3 OTHER DIESEL GROSS LINE FAIL CLEAR 11-19-19 11:17AM I31800 NOV 19, 2019 11:49 AM T 3 TANK Diesel PROBE OUT ALARM 11-19-19 v~ 11:17AM T 1 TANK Unleaded PROBE OUT CLEAR 11-19-19 I37400 11:17AM NOV 19, 2019 11:49 AM Diesel T 3 TANK SUDDEN LOSS ALARM ALARM 11-19-19 FOODS CO, 384 11:16AM 2501 HALEY BAKERSFIELD CA, Q 2 OTHER 91 661-873-9343 11:15AM UNLEADED PLLD SHUTDOWN ALARM CLEAR 11-19-19 PRESSURE LINE LEAK TEST HISTORY Q 2 OTHER 11:15AM 91 UNLEADED GROSS LINE FAIL CLEAR 11-19-19 Q 1 OTHER 87 Q 1:87 UNLEADED 11:14AM UNLEADED PLLD SHUTDOWN ALARM CLEAR 11-19-19 LAST 3,0 PASS: NOV 19, 2019 11: 14 AM Q l OTHER 11:14AM 87 UNLEADED GROSS LINE FAIL CLEAR 11-19-19 FIRST O .10 PASS EACH MONTH: T 1 TANK Unleaded SUDDEN LOSS ALARM CLEAR 11-19-19 11:14AM FIRST O, 20 PASS EACH MONTH: T 1 TANK unleaded PROBE OUT ALARM 11-19-19 Q 2: 91 UNLEADED 11:12AM LAST 3.0 PASS: NOV 19, 2019 11: 15 AM T 1 TANK 11:12AM Unleaded SUDDEN LOSS ALARM ALARM 11-19-19 FIRST 0.10 PASS EACH MONTH: Q 1 OTHER 87 UNLEADED PLLD SHUTDOWN ALARM ALARM 11-19-19 11:07AM FIRST 0.20 PASS EACH MONTH: Q 1 OTHER 87 Q 3 :DIESEL 11:00AM UNLEADED GROSS LINE FAIL ALARM 11-19-19 LAST 3, 0 PASS: NOV 19, 2019 11:17 AM Q 2 OTHER 10:49AM 91 UNLEADED PLLD SHUTDOWN ALARM ALARM 11-19-19 Q 2 OTHER 91 UNLEADED GROSS LINE FAIL ALARM 11-19-19 FIRST 0.10 PASS EACH MONTH: 10:49AM FIRST 0. 20 PASS EACH MONTH: Q 3 OTHER DIESEL 10:45AM PLLD SHUTDOWN ALARM ALARM 11-19-19 Q 3 OTHER DIESEL GROSS LINE FAIL ALARM 11-19-19 I38400 10:45AM NOV 19, 2019 11:49 AM Q 2 OTHER 91 UNLEADED PLLD SHUTDOWN ALARM CLEAR 11-19-19 FOODS CO, 384 10:31AM 2501 HALEY BAKERSFIELD CA, Q 1 OTHER 87 UNLEADED PLLD SHUTDOWN ALARM CLEAR 11-19-19 661-873-9343 10:31AM PRESSURE LINE LEAK TEST HISTORY L 6 DISP PAN DISP 10:31AM 11-12 DUAL SENSOR OUT ALARM CLEAR 11-19-19 L 5 DISP PAN DISP Q 1: 87 UNLEADED 10:31AM 9-10 DUAL SENSOR OUT ALARM CLEAR 11-19-19 LAST 3, 0 PASS: NOV 19, 2019 11:14 AM Q 3 OTHER IO: 31AM DIESEL PLLD SHUTDOWN ALARM CLEAR 11-19-19 FIRST 0.10 PASS EACH MONTH: L 4 DISP PAN DISP 7-8 DUAL SENSOR OUT ALARM CLEAR 11-19-19 10:31AM Q 2: 91 UNLEADED L 3 DISP PAN LAST 3.0 PASS: NOV 19, 2019 11: 15 AM 10:31AM DISP 5-6 DUAL SENSOR OUT ALARM CLEAR 11-19-19 L 2 DISP PAN DISP FIRST O .10 PASS EACH MONTH: 10:31AM 3-4 DUAL SENSOR OUT ALARM CLEAR 11-19-19 Q 3:DIESEL L15 PIPE 91 FILL SENSOR OUT ALARM CLEAR 11-19-19 10:31AM LAST 3,0 PASS: NOV 19, 2019 11: 17 AM L 8 STP SUMP 87 TURBINE SENSOR OUT ALARM CLEAR 11-19-19 10:31AM FIRST O. 10 PASS EACH MONTH: L 7 DISP PAN DISP 10:31AM 13-14 DUAL SENSOR OUT ALARM CLEAR 11-19-19 I38900 L 1 DISP PAN DISP 1-2 DUAL SENSOR OUT ALARM CLEAR 11-19-19 NOV 19, 2019 11:49 AM 10:31AM L20 PIPE DIESEL FILL SENSOR OUT ALARM CLEAR 11-19-19 10:31AM IlllOO NOV 19, 2019 11:49 AM Ll3 STP SUMP 91 TURBINE SENSOR OUT ALARM CLEAR 11-19-19 FOODS CO, 384 10:31AM 2501 HALEY Ll2 ANNULAR 87 ANNULAR SENSOR OUT ALARM CLEAR 11-19-19 BAKERSFIELD CA, 10:31AM 661-873-9343 LlO PIPE 87 FILL SENSOR OUT ALARM CLEAR 11-19-19 PRIORITY ALARM HISTORY 10:31AM ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME T 3 TANK Diesel PROBE OUT CLEAR 11-19-19 11: 26AM T 3 TANK Diesel OVERFILL ALARM CLEAR 11-19-19 I11200 11:25AM NOV 19, 2019 11:49 AM T 3 TANK Diesel PROBE OUT ALARM 11-19-19 11: 25AM FOODS CO, 384 Diesel 2501 HALEY T 3 TANK OVERFILL ALARM ALARM 11-19-19 BAKERSFIELD CA, 11: 25AM 661-873-9343 T 2 TANK Premuim PROBE OUT CLEAR 11-19-19 NON-PRIORITY ALARM HISTORY 11: 24AM ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE T 2 TANK Prernuim TIME Diesel OVERFILL ALARM CLEAR 11-19-19 T 3 TANK LOW TEMP WARNING CLEAR 11-19-19 11: 23AM 11: 26AM Premuim T 3 TANK Diesel LOW TEMP WARNING ALARM 11-19-19 T 2 TANK PROBE OUT ALARM 11-19-19 11:26AM 11: 23AM T 2 TANK Premuim LOW TEMP WARNING CLEAR 11-19-19 Premuim 11: 24AM T 2 TANK OVERFILL ALARM ALARM 11-19-19 Page 4 Alarm History T 2 TANK 11: 24AM T 1 TANK 11: 22AM T 1 TANK 11:22AM T 1 TANK 11: 22AM T 1 TANK 11: 20AM SYSTEM 6:22AM SYSTEM 6: 22AM SYSTEM 6:21AM SYSTEM 6: 21AM SYSTEM 6: 21AM SYSTEM 6:21AM SYSTEM 6:20AM SYSTEM 6: 20AM s 9 OTHER 10: 57PM s 9 OTHER 10:21PM hl2 OTHER ~wmHER 8:03AM SYSTEM 3: OSPM SYSTEM 3: OSPM SYSTEM 3 :OSPM SYSTEM 3:04PM OTHER 1:43PM SYSTEM 5 :06AM SYSTEM 5: 06AM SYSTEM 5 :OSAM SYSTEM 5: OSAM OTHER 8:03AM OTHER 8: 03AM OTHER 8:02AM OTHER 11: 22AM OTHER 8:02AM hl2 OTHER 8:00AM hl2 OTHER 8:01AM OTHER 12:27PM OTHER 8:02AM SYSTEM 11:46AM SYSTEM 11:46AM SYSTEM 11:45AM SYSTEM 11:45AM hl2 OTHER 8:00AM hl2 OTHER 8:04AM OTHER 9:03AM OTHER 8:03AM h 7 OTHER 8:00AM h 7 OTHER 8:03AM SYSTEM 7:07AM SYSTEM 7:07AM 111400 Premuim Unleaded unleaded Unleaded Unleaded 87 PRODUCT 87 PRODUCT FP12: BLEND3 FP12: BLEND3 FP12: BLEND3 FP12: BLEND3 FP12: BLEND3 FP12: BLEND3 FP7: BLEND3 FP7: BLEND3 NOV 19, 2019 11: 50 AM FOODS CO, 384 2501 HALEY BAKERSFIELD CA. 661-873-9343 LOW TEMP WARNING ALARM 11-19-19 LOW TEMP WARNING CLEAR 11-19-19 LOW TEMP WARNING ALARM 11-19-19 HIGH PRODUCT ALARM CLEAR 11-19-19 HIGH PRODUCT ALARM ALARM 11-19-19 PRINTER ERROR CLEAR 11-12-19 PAPER OUT CLEAR 11-12-19 PRINTER ERROR ALARM 11-12-19 PAPER OUT ALARM 11-12-19 PRINTER ERROR CLEAR 11-12-19 PAPER OUT CLEAR 11-12-19 PAPER OUT ALARM 11-12-19 PRINTER ERROR ALARM 11-12-19 VACUUM WARNING VACUUM WARNING FLOW COLLECT WARN FLOW COLLECT WARN PRINTER ERROR CLEAR 11-11-19 ALARM 11-11-19 CLEAR 10-10-19 ALARM 10-10-19 CLEAR 10-07-19 PAPER OUT CLEAR 10-07-19 PAPER OUT ALARM 10-07-19 PRINTER ERROR ALARM 10-07-19 ISD VAPOR LEAK WARN CLEAR 8-24-19 PRINTER ERROR CLEAR 8-22-19 PAPER OUT CLEAR 8-22-19 PAPER OUT ALARM 8-22-19 PRINTER ERROR ALARM 8-22-19 ISD VAPOR LEAK WARN ALARM 8-20-19 ISD VAPOR LEAK WARN CLEAR 8-14-19 ISD VAPOR LEAK WARN ALARM 8-07-19 ISD VAPOR LEAK WARN CLEAR 8-01-19 ISD VAPOR LEAK WARN ALARM 7-30-19 FLOW COLLECT WARN CLEAR 7-26-19 FLOW COLLECT WARN ALARM 7-25-19 ISD VAPOR LEAK WARN CLEAR 7-24-19 ISD VAPOR LEAK WARN ALARM 7-24-19 PRINTER ERROR CLEAR 7-10-19 PAPER OUT CLEAR 7-10-19 PRINTER ERROR ALARM 7-10-19 PAPER OUT ALARM 7-10-19 FLOW COLLECT WARN CLEAR 6-26-19 FLO\v COLLECT WARN ALARM 6-25-19 ISD SENSOR OUT WARN CLEAR 6-19-19 ISD SENSOR OUT WARN ALARM 6-19-19 FLOW COLLECT WARN FLOW COLLECT WARN PRINTER ERROR PRINTER ERROR CLEAR 6-07-19 ALARM 6-06-19 CLEAR 5-29-19 ALARM 5-29-19 Page S CLEARED ALARMS REPORT ID CATEGORY DESCRIPTION TIME T 3 TANK Diesel 11: 26AM T 3 TANK Diesel 11: 25AM T 2 TANK Premui m 11:24AM T 2 TANK Premui m 11: 23AM T 1 TANK Unleaded 11:22AM T 1 TANK Unleaded 11: 21AM T 3 TANK Diesel 11:19AM T 3 TANK Diesel 11:18AM T 3 TANK Diesel 11: 18AM Q 3 OTHER DIESEL 11:17AM Q 3 OTHER DIESEL 11: 17AM T 1 TANK Unleaded 11:17AM ~171~I~ER Q 2 OTHER 11:15AM ~1MmER ~1MmER T 1 TANK 11:14AM ~oMmER Q 1 OTHER 10:31AM 91 UNLEADED 91 UNLEADED 87 UNLEADED 87 UNLEADED unleaded 91 UNLEADED 87 UNLEADED L 6 DISP PAN DISP 11-12 DUAL 10:31AM L 5 DISP PAN DISP 9-10 DUAL 10:31AM ~oMmER DIESEL L 4 DISP PAN DISP 7-8 DUAL 10:31AM L 3 DISP PAN DISP 5-6 DUAL 10:31AM L 2 DISP PAN DISP 3-4 DUAL 10:31AM Ll5 PIPE 10: 31AM 91 FILL L 8 STP SUMP 87 TURBINE 10:31AM L 7 DISP PAN DISP 13-14 DUAL 10: 31AM L 1 DISP PAN DISP 1-2 DUAL 10:31AM L20 PIPE 10:31AM DIESEL FILL L13 STP SUMP 91 TURBINE 10:31AM Ll2 ANNULAR 87 ANNULAR 10:31AM LlO PIPE 87 FILL 10:31AM T 3 TANK Diesel 11:26AM T 2 TANK Premuim 11: 24AM T 1 TANK Un 1 eaded 11:22AM T 1 TANK unleaded 11: 22AM SYSTEM 6: 22AM SYSTEM 6: 22AM SYSTEM 6:21AM SYSTEM 6: 21AM s 9 OTHER 10:57PM hl2 OTHER 2: 35PM SYSTEM 3 :05PM SYSTEM 3:05PM OTHER 1: 43PM SYSTEM 5 :06AM SYSTEM 5: 06AM OTHER 8: 03AM Alarm History 87 PRODUCT FP12: BLEND3 ALARM TYPE STATE DATE PROBE OUT CLEAR 11-19-19 OVERFILL ALARM CLEAR 11-19-19 PROBE OUT CLEAR 11-19-19 OVERFILL ALARM CLEAR 11-19-19 PROBE OUT CLEAR 11-19-19 OVERFILL ALARM CLEAR 11-19-19 PROBE OUT CLEAR 11-19-19 PROBE OUT CLEAR 11-19-19 SUDDEN LOSS ALARM CLEAR 11-19-19 PLLD SHUTDOWN ALARM CLEAR 11-19-19 GROSS LINE FAIL CLEAR 11-19-19 PROBE OUT CLEAR 11-19-19 PLLD SHUTDOWN ALARM CLEAR 11-19-19 GROSS LINE FAIL CLEAR 11-19-19 PLLD SHUTDOWN ALARM CLEAR 11-19-19 GROSS LINE FAIL CLEAR 11-19-19 SUDDEN LOSS ALARM CLEAR 11-19-19 PLLD SHUTDOWN ALARM CLEAR 11-19-19 PLLD SHUTDOWN ALARM CLEAR 11-19-19 SENSOR OUT ALARM CLEAR 11-19-19 SENSOR OUT ALARM CLEAR 11-19-19 PLLD SHUTDOWN ALARM CLEAR 11-19-19 SENSOR OUT ALARM CLEAR 11-19-19 SENSOR OUT ALARM CLEAR 11-19-19 SENSOR OUT ALARM SENSOR OUT ALARM SENSOR OUT ALARM SENSOR OUT ALARM CLEAR 11-19-19 CLEAR 11-19-19 CLEAR 11-19-19 CLEAR 11-19-19 SENSOR OUT ALARM CLEAR 11-19-19 SENSOR OUT ALARM CLEAR 11-19-19 SENSOR OUT ALARM CLEAR 11-19-19 SENSOR OUT ALARM CLEAR 11-19-19 SENSOR OUT ALARM CLEAR 11-19-19 LOW TEMP WARNING CLEAR 11-19-19 LOW TEMP WARNING CLEAR 11-19-19 LOW TEMP WARNING CLEAR 11-19-19 HIGH PRODUCT ALARM CLEAR 11-19-19 PRINTER ERROR CLEAR 11-12-19 PAPER OUT CLEAR 11-12-19 PRINTER ERROR PAPER OUT VACUUM WARNING FLOW COLLECT WARN PRINTER ERROR PAPER OUT CLEAR 11-12-19 CLEAR 11-12-19 CLEAR 11-11-19 CLEAR 10-10-19 CLEAR 10-07-19 CLEAR 10-07-19 ISD VAPOR LEAK WARN CLEAR 8-24-19 PRINTER ERROR PAPER OUT CLEAR CLEAR ISD VAPOR LEAK WARN CLEAR 8-22-19 8-22-19 8-14-19 OTHER 11: 22AM ISD VAPOR LEAK WARN CLEAR 8-01-19 hl2 OTHER 8:00AM FP12: BLEND3 FLOW COLLECT WARN CLEAR 7-26-19 OTHER 12: 27PM ISD VAPOR LEAK WARN CLEAR 7-24-19 SYSTEM 11:46AM PRINTER ERROR CLEAR 7-10-19 SYSTEM 11:46AM PAPER OUT CLEAR 7-10-19 hl2 OTHER 8:00AM FP12: BLEND3 FLOW COLLECT WARN CLEAR 6-26-19 OTHER ISD SENSOR OUT WARN 9:03AM CLEAR 6-19-19 h 7 OTHER 8:00AM FP7: BLEND3 FLOW COLLECT WARN CLEAR 6-07-19 SYSTEM 7:07AM PRINTER ERROR CLEAR 5-29-19 Il1300 NOV 19, 2019 11: so AM FOODS CO. 384 2501 HALEY BAKERSFIELD CA. 661-873-9343 ACTIVE ALARMS REPORT ID CATEGORY DESCRIPTION ALARM TYPE DATE TIME Page 6 Al arm Hi story