Loading...
HomeMy WebLinkAbout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ame as Facility Name or DBA-Doing Business As) %XVLQHVV6LWH$GGUHVV &LW\ =,3&RGH ,, 81'(5*5281'6725$*(7$1.6(59,&(7(&+1,&,$1,1)250$7,21 1DPHRI&RPSDQ\3HUIRUPLQJWKH&HUWLILFDWLRQ 3KRQH 0DLOLQJ$GGUHVV 1DPHRI8676HUYLFH7HFKQLFLDQ3HUIRUPLQJWKH&HUWLILFDWLRQ(Print as shown on the ICC Certification) &RQWUDFWRU7DQN7HVWHU/LFHQVH ,&&&HUWLILFDWLRQ ,&&&HUWLILFDWLRQ([SLUDWLRQ'DWH 0RQLWRULQJ6\VWHP7UDLQLQJDQG&HUWLILFDWLRQV(List all applicable certifications.) ([SLUDWLRQ'DWH ,,, 5(68/762)7(67,1*6(59,&,1* Indicate and attach the following reports if the monitoring equipment is capable of generating either.<11$0RQLWRULQJ6\VWHP6HWXS$ODUP+LVWRU\5HSRUW :DVDQ\PRQLWRULQJHTXLSPHQWUHSODFHG" (If “Yes,” identify the specific devices replaced and list the manufacturer and model for all replacement parts in section IV below.) :DVGDPDJHGHEULVRUOLTXLGIRXQGLQVLGHDQ\VHFRQGDU\FRQWDLQPHQWV\VWHPV" (If “Yes,” describe what was found in section IV below.) ,VDOOPRQLWRULQJHTXLSPHQWRSHUDWLRQDOSHUPDQXIDFWXUHU¶VVSHFLILFDWLRQV" (If “No,” describe why in section IV below.) ,9 &200(176 If directed to use this section, describe how and when the issues were or will be corrected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hell 5700 Auburn Street Bakersfield 93306 16250 Meacham Road, Bakersfield, CA 93314 Frank Amestoy 804904 8374998 11/14/2019 Veeder root B46603 8/3/2019 91 fill cap was bad replaced with new cap Diesel leak Detector failed replaced with new FX1DV V/R battery was bad replaced with new oneL21: 208 sensor was bad replaced with new one. Confidence UST Services, Inc. (800) 339-9930 ,' ,GHQWLILFDWLRQ6: 6LQJOH:DOOHG93+ 9DFXXP3UHVVXUH+\GURVWDWLF//' /LQH/HDN'HWHFWRU 81 ZZZXQLGRFVRUJ 5HY 81'(5*5281'6725$*(7$1. 021,725,1*6<67(0&(57,),&$7,21)250 3DJHRI  9, ,19(1725<2)(48,30(17&(57,),(' A separate Monitoring System Certification Form must be prepared for each monitoring system control panel. 0DNHRI0RQLWRULQJ6\VWHP&RQWURO3DQHO  0RGHORI0RQLWRULQJ6\VWHP&RQWURO3DQHO  6RIWZDUH9HUVLRQ,QVWDOOHG  Check the appropriate boxes to indicate specific equipment inspected/serviced. 0RQLWRULQJ'HYLFH8VHG'HYLFH0RGHO0RQLWRULQJ'HYLFH8VHG'HYLFH0RGHO 7$1.,' (By tank number, stored product, etc.) 7$1.,' (By tank number, stored product, etc.) ,Q7DQN*DXJLQJ(SW Tank),Q7DQN*DXJLQJ(SW Tank) $QQXODU6SDFHRU9DXOW6HQVRU$QQXODU6SDFHRU9DXOW6HQVRU 93+6HQVRU93+6HQVRU 3URGXFW3LSLQJ3URGXFW3LSLQJ 0HFKDQLFDO//'0HFKDQLFDO//' (OHFWURQLF//'(OHFWURQLF//' 93+6HQVRU 3LSLQJ 93+6HQVRU 3LSLQJ  6XPS6HQVRU6XPS6HQVRU 93+6HQVRU 6XPS 93+6HQVRU 6XPS  )LOO3LSLQJ)LOO3LSLQJ 93+6HQVRU 3LSLQJ 93+6HQVRU 3LSLQJ  6XPS6HQVRU6XPS6HQVRU 93+6HQVRU 6XPS 93+6HQVRU 6XPS  9HQW3LSLQJ9HQW3LSLQJ 93+6HQVRU 3LSLQJ 93+6HQVRU 3LSLQJ  6XPS6HQVRU6XPS6HQVRU 93+6HQVRU 6XPS 93+6HQVRU 6XPS  9DSRU5HFRYHU\3LSLQJ9DSRU5HFRYHU\3LSLQJ 93+6HQVRU 3LSLQJ 93+6HQVRU 3LSLQJ  6XPS6HQVRU6XPS6HQVRU 93+6HQVRU 6XPS 93+6HQVRU 6XPS  0RQLWRULQJ'HYLFH8VHG 'HYLFH0RGHO0RQLWRULQJ'HYLFH8VHG 'HYLFH0RGHO 7$1.,' (By tank number, stored product, etc.) 7$1.,' (By tank number, stored product, etc.) ,Q7DQN*DXJLQJ(SW Tank),Q7DQN*DXJLQJ(SW Tank) $QQXODU6SDFHRU9DXOW6HQVRU$QQXODU6SDFHRU9DXOW6HQVRU 93+6HQVRU93+6HQVRU 3URGXFW3LSLQJ3URGXFW3LSLQJ 0HFKDQLFDO//'0HFKDQLFDO//' (OHFWURQLF//'(OHFWURQLF//' 93+6HQVRU 3LSLQJ 93+6HQVRU 3LSLQJ  6XPS6HQVRU6XPS6HQVRU 93+6HQVRU 6XPS 93+6HQVRU 6XPS  )LOO3LSLQJ)LOO3LSLQJ 93+6HQVRU 3LSLQJ 93+6HQVRU 3LSLQJ  6XPS6HQVRU6XPS6HQVRU 93+6HQVRU 6XPS 93+6HQVRU 6XPS  9HQW3LSLQJ9HQW3LSLQJ 93+6HQVRU 3LSLQJ 93+6HQVRU 3LSLQJ  6XPS6HQVRU6XPS6HQVRU 93+6HQVRU 6XPS 93+6HQVRU 6XPS  9DSRU5HFRYHU\3LSLQJ9DSRU5HFRYHU\3LSLQJ 93+6HQVRU 3LSLQJ 93+6HQVRU 3LSLQJ  6XPS6HQVRU6XPS6HQVRU 93+6HQVRU 6XPS 93+6HQVRU 6XPS  Veeder root TLS-350 327.04 T1: 87 20,000 847390-107 794380-303 FX1V 330020-463/330020-464 794380-208 794380-304 794380-208 794380-304 330020-463/330020-464 330020-463/330020-464 T2: 91 12,000 847390-107 794380-303 FX1V 330020-463/330020-464 794380-208 794380-304 794380-208 794389-304 330020-463/330020-464 330020-463/330020-464 T3: Diesel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pecify in section VII.)2WKHU(Specify in section VII.) 2WKHU0RQLWRUHG&RPSRQHQW,'2WKHU0RQLWRUHG&RPSRQHQW,' 2WKHU(Specify in section VII.)2WKHU(Specify in section VII.) 2WKHU0RQLWRUHG&RPSRQHQW,'2WKHU0RQLWRUHG&RPSRQHQW,' 2WKHU(Specify in section VII.)2WKHU(Specify in section VII.) Include information for every underground storage tank component monitored by this monitoring system control panel. If the monitoring system control panel monitors more components than this form accommodates, additional copies of these pages may be attached. 9,, &200(176 Use this section to provide additional comments about the inventory of the equipment certified.  1-2 794380-208 794380-304 3-4 794380-208 794380-304 5-6 794380-208 794380-304 7-8 794380-208 794380-304 9-10 794380-208 794380-304 11-12 794380-208 794380-304 < <HV1 1R1$ 1RW$SSOLFDEOH 81 ZZZXQLGRFVRUJ 5HY 81'(5*5281'6725$*(7$1. 021,725,1*6<67(0&(57,),&$7,21)250 3DJHRI  9,,, 021,725,1*6<67(0$1'352*5$00,1* This section must be completed if a monitoring panel is used to perform leak detection monitoring.<11$ $UHWKHYLVXDODQGDXGLEOHDODUPVRSHUDWLRQDO" :HUHDOOVHQVRUVYLVXDOO\LQVSHFWHGIRUNLQNVDQGEUHDNVLQWKHFDEOHVDQGIRUUHVLGXDOEXLOGXSWRHQVXUHWKDWIORDWVPRYHIUHHO\ IXQFWLRQDOO\WHVWHGDQGFRQILUPHGRSHUDWLRQDO" :HUHDOOVHQVRUVLQVWDOOHGDWORZHVWSRLQWRIVHFRQGDU\FRQWDLQPHQWDQGSRVLWLRQHGVRWKDWRWKHUHTXLSPHQWZLOOQRWLQWHUIHUHZLWK WKHLUSURSHURSHUDWLRQ" :DVPRQLWRULQJV\VWHPVHWXSUHYLHZHGWRHQVXUHSURSHUVHWWLQJV" :DVWKHPRQLWRULQJSDQHO¶VEDFNXSEDWWHU\YLVXDOO\LQVSHFWHGIXQFWLRQDOO\WHVWHGDQGFRQILUPHGRSHUDWLRQDO" 'RHVWKHIORZRIIXHOVWRSDWWKHGLVSHQVHULIDOHDNLVGHWHFWHGLQWKHXQGHUGLVSHQVHUFRQWDLQPHQW" 'RHVWKHWXUELQHDXWRPDWLFDOO\VKXWGRZQLIWKHSLSLQJVHFRQGDU\FRQWDLQPHQWPRQLWRULQJV\VWHPIDLOVWRRSHUDWHRULVHOHFWULFDOO\ GLVFRQQHFWHG" 'RHVWKHWXUELQHDXWRPDWLFDOO\VKXWGRZQLIWKHSLSLQJVHFRQGDU\FRQWDLQPHQWPRQLWRULQJV\VWHPGHWHFWVDOHDN" :KLFKVHQVRUVLQLWLDWHSRVLWLYHVKXWGRZQ"(Check all that apply.)6XPS8QGHU'LVSHQVHU&RQWDLQPHQW ,IDODUPVDUHUHOD\HGWRDUHPRWHPRQLWRULQJVWDWLRQLVDOOFRPPXQLFDWLRQVHTXLSPHQW HJPRGHP RSHUDWLRQDO" For any answer of “N” above, describe in Section IX how and when these deficiencies were or will be corrected. ,; &200(176 ; ,17$1.*$8*,1*7(67,1* &KHFNWKLVER[LIWDQNJDXJLQJLVXVHGRQO\IRULQYHQWRU\FRQWURO(Do not complete this section.) <11$&KHFNWKLVER[LI12WDQNJDXJLQJHTXLSPHQWLVLQVWDOOHG (Do not complete this section.) This section must be completed if in-tank gauging is used to perform leak detection monitoring. +DVDOOLQSXWZLULQJEHHQLQVSHFWHGIRUNLQNVDQGEUHDNVLQWKHFDEOHVDQGIRUSURSHUHQWU\DQGWHUPLQDWLRQLQFOXGLQJWHVWLQJIRU JURXQGIDXOWV" :HUHDOOLQWDQNJDXJLQJSUREHVYLVXDOO\LQVSHFWHGIRUGDPDJHDQGUHVLGXHEXLOGXSWRHQVXUHWKDWIORDWVPRYHIUHHO\IXQFWLRQDOO\ WHVWHGDQGFRQILUPHGRSHUDWLRQDO" :DVDFFXUDF\RIV\VWHP¶VSURGXFWOHYHOUHDGLQJVWHVWHG" :DVDFFXUDF\RIV\VWHP¶VZDWHUOHYHOUHDGLQJVWHVWHG" :HUHDOOSUREHVUHLQVWDOOHGSURSHUO\" :HUHDOOLWHPVRQWKHHTXLSPHQWPDQXIDFWXUHU¶VPDLQWHQDQFHFKHFNOLVWFRPSOHWHG" For any answer of “N” above, describe in Section XI how and when these deficiencies were or will be corrected. ;, &200(176 L21: 87 STP 208 sensor was bad replaced with new one. V/R battery was bad replaced with new one *3+ *DOORQV3HU+RXU< <HV1 1R1$ 1RW$SSOLFDEOH93+ 9DFXXP3UHVVXUH+\GURVWDWLF,' ,GHQWLILFDWLRQ 81 ZZZXQLGRFVRUJ5HY 81'(5*5281'6725$*(7$1. 021,725,1*6<67(0&(57,),&$7,21)250 3DJHRI  ;,, /,1(/($.'(7(&7257(67,1* &KHFNWKLVER[LIOLQHOHDNGHWHFWRUV //' DUH127LQVWDOOHG(Do not complete this section.)<11$This section must be completed if LLDs are installed. :DVDOHDNVLPXODWHGWRYHULI\//'SHUIRUPDQFH" (Check all that apply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¶VPDLQWHQDQFHFKHFNOLVWFRPSOHWHG" :HUHDOO//'VFRQILUPHGRSHUDWLRQDOZLWKLQUHJXODWRU\UHTXLUHPHQWV" For any answer of “N” above, describe in Section XIII how and when these issues were or will be corrected. ;,,, &200(176 ;,9 9$&88035(6685(+<'5267$7,&021,725,1*(48,30(177(67,1* &KHFNWKLVER[LI93+PRQLWRULQJLV127XVHG(Do not complete this section.) This section must be completed if VPH monitoring is used to perform leak detection monitoring. 6\VWHP7\SH 0DUNDOOWKDWDSSO\ 9DFXXP3UHVVXUH+\GURVWDWLF 6HQVRU,'&RPSRQHQW 6 0RQLWRUHG%\7KLV6HQVRU 6HQVRU)XQFWLRQDOLW\ 7HVW ,QWHUVWLWLDO&RPPXQLFDWLRQ 7HVW 3DVV )DLO 3DVV )DLO 3DVV)DLO3DVV)DLO 3DVV)DLO3DVV)DLO 3DVV)DLO3DVV)DLO 3DVV)DLO3DVV)DLO 3DVV)DLO3DVV)DLO 3DVV)DLO3DVV)DLO 3DVV)DLO3DVV)DLO 3DVV)DLO3DVV)DLO 3DVV)DLO3DVV)DLO 3DVV)DLO3DVV)DLO 3DVV)DLO3DVV)DLO +RZZDVLQWHUVWLWLDOFRPPXQLFDWLRQYHULILHG"6LPXODWHG/HDNDW)DU(QGVRIWKH,QWHUVWLWLDO6SDFH9LVXDO,QVSHFWLRQ 2WKHU(Describe the method in section XV below.)*DXJH :DVWKHYDFXXPRUSUHVVXUHUHVWRUHGWRRSHUDWLQJOHYHOVLQDOOLQWHUVWLWLDOVSDFHV"<HV1R(Describe the reason in section XV below.) For any answer of “Fail” above, describe in Section XV how and when these issues were or will be corrected. ;9 &200(176 Diesel LLD failed replaced with new one S8 87 product S9 91 vent S10 87/91 vapor S11 87 vent S12 91 product S13 91 vent S14 Diesel product S15 Diesel vent Fairfax shell mart avo setup Responses Received: 200 FAIRFAX SHELL MART 5700 AUBURN ST BAKERSFIELD CA 93306 661 873 7730 06-13-19 9:18 AM TANK PRODUCT GALLONS INCHES WATER DEG F ULLAGE 1 UNLEADED 2871 24.09 0.0 83.0 16832 2 PREMIUM 1037 12.93 0.0 86.3 10490 3 DIESEL 926 11.96 0.0 90.2 10601 I90500 06-13-19 9:18 AM SOFTWARE REVISION LEVEL VERSION 327.04 SOFTWARE# 346327-100-E CREATED - 07.02.06.10.28 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD PMC I50500 06-13-19 9:18 AM SYSTEM TYPE AND LANGUAGE FLAG SYSTEM UNITS U.S. SYSTEM LANGUAGE ENGLISH SYSTEM DATE/TIME FORMAT MM-DD-YY HH:MM:SS xM I50201 06-13-19 9:18 AM SHIFT TIME 1 : 6:00 AM I50202 06-13-19 9:18 AM SHIFT TIME 2 : DISABLED I50203 06-13-19 9:18 AM SHIFT TIME 3 : DISABLED I50204 06-13-19 9:18 AM SHIFT TIME 4 : DISABLED I54600 06-13-19 9:18 AM TANK PER TST NEEDED WRN: DISABLED I54900 06-13-19 9:18 AM TANK ANN TST NEEDED WRN: DISABLED I55300 06-13-19 9:18 AM LINE RE-ENABLE METHOD PASS LINE TEST I55600 06-13-19 9:18 AM LINE PER TST NEEDED WRN: DISABLED I55900 06-13-19 9:18 AM LINE ANN TST NEEDED WRN: DISABLED I50D00 06-13-19 9:18 AM PRINT TC VOLUMES ENABLED I50E00 06-13-19 9:18 AM TEMP COMPENSATION VALUE (DEG F ): 60.0 I60B00 06-13-19 9:18 AM STICK HEIGHT OFFSET ENABLE STATUS DISABLED I51400 06-13-19 9:18 AM H-PROTOCOL DATA FORMAT HEIGHT I51A01 06-13-19 9:18 AM DAYLIGHT SAVING TIME ENABLED ON I51B00 06-13-19 9:19 AM DAYLIGHT SAVING TIME START DATE APR WEEK 1 SUN 2:00 AM END DATE OCT WEEK 6 SUN 2:00 AM I51600 06-13-19 9:19 AM RE-DIRECT LOCAL PRINTOUT DISABLED I50400 06-13-19 9:19 AM 232 SECURITY CODE PORT SECURITY CODE STATUS 1 000000 DISABLED 2 000000 DISABLED 3 000000 DISABLED 4 000000 DISABLED 5 000000 DISABLED 6 000000 DISABLED I21900 06-13-19 9:19 AM TANK CHART SECURITY DISABLED I5BD00 06-13-19 9:19 AM CUSTOM ALARM LABELS DISABLED I56000 06-13-19 9:19 AM MASS/DENSITY DISABLED I88101 06-13-19 9:19 AM PORT SETTINGS: COMM BOARD : 1 (EDIM ) RS-232 SECURITY CODE : DISABLED I88102 06-13-19 9:19 AM PORT SETTINGS: COMM BOARD : 2 (RS-232) BAUD RATE : 9600 PARITY : NONE STOP BIT : 2 STOP DATA LENGTH: 7 DATA RS-232 SECURITY CODE : DISABLED I88103 06-13-19 9:19 AM I88104 06-13-19 9:19 AM I88105 06-13-19 9:19 AM I88106 06-13-19 9:19 AM I52000 06-13-19 9:19 AM RECEIVER AUTO DIAL TYPE & START TIME RCVR LOCATION LABEL DIAL TYPE START TIME 1 ON DATE MAR 11, 2012 DISABLED 2 ON DATE MAR 11, 2012 DISABLED 3 ON DATE MAR 11, 2012 DISABLED 4 ON DATE MAR 11, 2012 DISABLED 5 ON DATE MAR 11, 2012 DISABLED 6 ON DATE MAR 11, 2012 DISABLED 7 ON DATE MAR 11, 2012 DISABLED 8 ON DATE MAR 11, 2012 DISABLED I60100 06-13-19 9:19 AM TANK CONFIGURATION DEVICE LABEL CONFIGURED 1 UNLEADED ON 2 PREMIUM ON 3 DIESEL ON 4 OFF I60200 06-13-19 9:19 AM TANK PRODUCT LABEL TANK PRODUCT LABEL 1 UNLEADED 2 PREMIUM 3 DIESEL 4 I60300 06-13-19 9:19 AM TANK PRODUCT CODE TANK PRODUCT LABEL 1 UNLEADED 1 2 PREMIUM 2 3 DIESEL 3 4 4 I60900 06-13-19 9:19 AM TANK THERMAL COEFFICIENT TANK PRODUCT LABEL 1 UNLEADED 0.000700 2 PREMIUM 0.000700 3 DIESEL 0.000450 4 0.000000 I60700 06-13-19 9:19 AM TANK DIAMETER TANK PRODUCT LABEL INCHES 1 UNLEADED 117.75 2 PREMIUM 89.75 3 DIESEL 89.75 4 0.00 I60A00 06-13-19 9:19 AM TANK FULL VOLUME TANK PRODUCT LABEL TANK PROFILE GALLONS 1 UNLEADED 4 PTS 19703 2 PREMIUM 4 PTS 11527 3 DIESEL 4 PTS 11527 4 1 PT 0 I60400 06-13-19 9:19 AM TANK FULL VOLUME TANK PRODUCT LABEL GALLONS 1 UNLEADED 19703 2 PREMIUM 11527 3 DIESEL 11527 4 0 I60500 06-13-19 9:19 AM TANK 4 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 UNLEADED 19703 16062 9961 3824 2 PREMIUM 11527 9379 5836 2271 3 DIESEL 11527 9379 5836 2271 4 0 0 0 0 I60600 06-13-19 9:19 AM TANK 20 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 UNLEADED 19703 0 0 0 0 16062 0 0 0 0 9961 0 0 0 0 3824 0 0 0 0 2 PREMIUM 11527 0 0 0 0 9379 0 0 0 0 5836 0 0 0 0 2271 0 0 0 0 3 DIESEL 11527 0 0 0 0 9379 0 0 0 0 5836 0 0 0 0 2271 0 0 0 0 4 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 I61500 06-13-19 9:19 AM TANK PRODUCT LABEL METER DATA 1 UNLEADED NO 2 PREMIUM NO 3 DIESEL NO 4 NO I62F00 06-13-19 9:19 AM MAG PROBE FLOAT SIZE TANK PRODUCT LABEL FLOAT SIZE: 1 UNLEADED 3.0 INCHES 2 PREMIUM 3.0 INCHES 3 DIESEL 3.0 INCHES I62700 06-13-19 9:19 AM TANK HIGH WATER WARNING LIMIT TANK PRODUCT LABEL INCHES 1 UNLEADED 2.0 2 PREMIUM 2.0 3 DIESEL 2.0 9999FF1B I62400 06-13-19 9:19 AM TANK HIGH WATER LEVEL LIMIT TANK PRODUCT LABEL INCHES 1 UNLEADED 3.0 2 PREMIUM 3.0 3 DIESEL 3.0 I62800 06-13-19 9:19 AM TANK MAXIMUM VOLUME LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 19703 2 PREMIUM 11527 3 DIESEL 11527 4 0 I62300 06-13-19 9:19 AM TANK OVERFILL LEVEL LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 17732 2 PREMIUM 10374 3 DIESEL 10374 4 0 I62200 06-13-19 9:19 AM TANK HIGH PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 18718 2 PREMIUM 10950 3 DIESEL 10950 4 0 I62900 06-13-19 9:19 AM TANK DELIVERY REQUIRED LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 2000 2 PREMIUM 1200 3 DIESEL 1200 4 0 I62100 06-13-19 9:19 AM TANK LOW PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 1500 2 PREMIUM 1000 3 DIESEL 1000 4 0 I62600 06-13-19 9:19 AM TANK LEAK ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 99 2 PREMIUM 99 3 DIESEL 99 4 99 I62500 06-13-19 9:19 AM TANK SUDDEN LOSS LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 50 2 PREMIUM 50 3 DIESEL 50 4 99 I60800 06-13-19 9:19 AM TANK TILT TANK PRODUCT LABEL INCHES 1 UNLEADED 0.00 2 PREMIUM 0.00 3 DIESEL 0.00 4 0.00 I60B00 06-13-19 9:19 AM STICK HEIGHT OFFSET ENABLE STATUS DISABLED I60C00 06-13-19 9:19 AM TANK STICK HEIGHT OFFSET TANK PRODUCT LABEL INCHES 1 UNLEADED 0.00 2 PREMIUM 0.00 3 DIESEL 0.00 4 0.00 I61200 06-13-19 9:19 AM TANK MANIFOLDED PARTNERS TANK PRODUCT LABEL SIPHON MANIFOLDED TANKS LINE MANIFOLDED TANKS 1 UNLEADED NONE NONE 2 PREMIUM NONE NONE 3 DIESEL NONE NONE 4 NONE NONE I63600 06-13-19 9:19 AM PERIODIC LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 UNLEADED 2000 2 PREMIUM 1200 3 DIESEL 1200 4 0 I62A00 06-13-19 9:19 AM ANNUAL LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 UNLEADED 2000 2 PREMIUM 1200 3 DIESEL 1200 4 0 I62C00 06-13-19 9:19 AM TANK PERIODIC TEST TYPE TANK PRODUCT LABEL PERIODIC TEST TYPE 1 UNLEADED STANDARD 2 PREMIUM STANDARD 3 DIESEL STANDARD 4 STANDARD I62D00 06-13-19 9:19 AM TANK LEAK TEST FAIL ALARMS TANK PRODUCT LABEL 1 UNLEADED GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 2 PREMIUM GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 3 DIESEL GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 4 GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED I63100 06-13-19 9:19 AM TANK LEAK TEST AVERAGING TANK PRODUCT LABEL ANNUAL PERIODIC 1 UNLEADED OFF OFF 2 PREMIUM OFF OFF 3 DIESEL OFF OFF 4 OFF OFF I63000 06-13-19 9:19 AM IN-TANK LEAK TEST NOTIFY TANK PRODUCT LABEL TANK TEST NOTIFY: 1 UNLEADED OFF 2 PREMIUM OFF 3 DIESEL OFF 4 OFF I63200 06-13-19 9:19 AM TANK TEST SIPHON BREAK TANK PRODUCT LABEL SIPHON BREAK 1 UNLEADED OFF 2 PREMIUM OFF 3 DIESEL OFF 4 OFF I61000 06-13-19 9:19 AM TANK DELIVERY DELAY TANK PRODUCT LABEL 1 UNLEADED 15 2 PREMIUM 15 3 DIESEL 15 4 1 I63A00 06-13-19 9:19 AM LOW LEVEL PUMP THRESHOLD FOR SEQUENTIAL LINE MANIFOLD TANK PRODUCT LABEL PUMP THRESHOLD 1 UNLEADED 10.00% 2 PREMIUM 10.00% 3 DIESEL 10.00% 4 10.00% I61100 06-13-19 9:19 AM LEAK TEST METHOD - - - - - - - - - - - - TEST ANNUALLY: ALL TANK DEC WEEK 1 SUN START TIME : 2:30 AM TEST RATE :0.20 GAL/HR DURATION : 2 HOURS TST EARLY STOP:DISABLED I61300 06-13-19 9:19 AM CSLD PROBABLITY OF DETECTION I61400 06-13-19 9:19 AM CSLD CLIMATE FACTOR I61600 06-13-19 9:19 AM TANK PRODUCT LABEL CAL UPDATE 1 UNLEADED IMMEDIATE 2 PREMIUM IMMEDIATE 3 DIESEL IMMEDIATE 4 IMMEDIATE I61A00 06-13-19 9:19 AM IN-TANK LEAK TEST EARLY STOP TANK PRODUCT LABEL TST EARLY STOP: 1 UNLEADED DISABLED 2 PREMIUM DISABLED 3 DIESEL DISABLED 4 DISABLED I61B00 06-13-19 9:19 AM IN-TANK LEAK GROSS TEST AUTO-CONFIRM I61C00 06-13-19 9:19 AM CSLD REPORT ONLY I62B00 06-13-19 9:19 AM TANK LAST ANNUAL TEST TANK PRODUCT LABEL DATE 1 UNLEADED 00-00-00 2 PREMIUM 00-00-00 3 DIESEL 00-00-00 4 00-00-00 I63300 06-13-19 9:19 AM LEAK TEST REPORT FORMAT: NORMAL I63400 06-13-19 9:19 AM RECONCILIATION WARNING LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 0 2 PREMIUM 0 3 DIESEL 0 4 0 I63500 06-13-19 9:19 AM RECONCILIATION ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 1 2 PREMIUM 1 3 DIESEL 1 4 1 I63900 06-13-19 9:19 AM ACCU CHART END SHAPE FACTOR TANK PRODUCT LABEL 1 UNLEADED END FACTOR: NONE 2 PREMIUM END FACTOR: NONE 3 DIESEL END FACTOR: NONE 4 END FACTOR: NONE I78000 06-13-19 9:19 AM I77700 06-13-19 9:19 AM I77800 06-13-19 9:19 AM I78C00 06-13-19 9:19 AM I78300 06-13-19 9:19 AM I78F00 06-13-19 9:19 AM I78700 06-13-19 9:19 AM I70200 06-13-19 9:19 AM LIQUID LABEL DEVICE LABEL 1 UNL TANK ANN 2 PREM TANK ANN 3 DIESEL TANK ANN 4 5 6 7 8 9 DIESEL STP 10 DIESEL STP ANN 11 UNL FILL 12 UNL FILL ANN 13 PREM FILL ANN 14 PREM FILL 15 DIESEL FILL 16 DIESEL FILL ANN 17 DIS 9-10 18 DIS 9-10 ANN 19 DIS 11-12 20 DIS 11-12 ANN 21 UNL STP 22 UNL STP ANN 23 PREM STP 24 PREM STP ANN 25 DIS 1-2 26 DIS 1-2 ANN 27 DIS 3-4 28 DIS 3-4 ANN 29 DIS 5-6 30 DIS 5-6 ANN 31 DIS 7-8 32 DIS 7-8 ANN I70300 06-13-19 9:19 AM LIQUID TYPE SENSOR LOCATION TYPE 1 UNL TANK ANN DUAL POINT HYDROSTATIC 2 PREM TANK ANN DUAL POINT HYDROSTATIC 3 DIESEL TANK ANN DUAL POINT HYDROSTATIC 4 TRI-STATE (SINGLE FLOAT) 5 TRI-STATE (SINGLE FLOAT) 6 TRI-STATE (SINGLE FLOAT) 7 TRI-STATE (SINGLE FLOAT) 8 TRI-STATE (SINGLE FLOAT) 9 DIESEL STP TRI-STATE (SINGLE FLOAT) 10 DIESEL STP ANN TRI-STATE (SINGLE FLOAT) 11 UNL FILL TRI-STATE (SINGLE FLOAT) 12 UNL FILL ANN TRI-STATE (SINGLE FLOAT) 13 PREM FILL ANN TRI-STATE (SINGLE FLOAT) 14 PREM FILL TRI-STATE (SINGLE FLOAT) 15 DIESEL FILL TRI-STATE (SINGLE FLOAT) 16 DIESEL FILL ANN TRI-STATE (SINGLE FLOAT) 17 DIS 9-10 TRI-STATE (SINGLE FLOAT) 18 DIS 9-10 ANN TRI-STATE (SINGLE FLOAT) 19 DIS 11-12 TRI-STATE (SINGLE FLOAT) 20 DIS 11-12 ANN TRI-STATE (SINGLE FLOAT) 21 UNL STP TRI-STATE (SINGLE FLOAT) 22 UNL STP ANN TRI-STATE (SINGLE FLOAT) 23 PREM STP TRI-STATE (SINGLE FLOAT) 24 PREM STP ANN TRI-STATE (SINGLE FLOAT) 25 DIS 1-2 TRI-STATE (SINGLE FLOAT) 26 DIS 1-2 ANN TRI-STATE (SINGLE FLOAT) 27 DIS 3-4 TRI-STATE (SINGLE FLOAT) 28 DIS 3-4 ANN TRI-STATE (SINGLE FLOAT) 29 DIS 5-6 TRI-STATE (SINGLE FLOAT) 30 DIS 5-6 ANN TRI-STATE (SINGLE FLOAT) 31 DIS 7-8 TRI-STATE (SINGLE FLOAT) 32 DIS 7-8 ANN TRI-STATE (SINGLE FLOAT) I70400 06-13-19 9:19 AM LIQUID CATEGORY SENSOR LOCATION CATEGORY 1 UNL TANK ANN ANNULAR SPACE 2 PREM TANK ANN ANNULAR SPACE 3 DIESEL TANK ANN ANNULAR SPACE 4 OTHER SENSORS 5 OTHER SENSORS 6 OTHER SENSORS 7 OTHER SENSORS 8 OTHER SENSORS 9 DIESEL STP STP SUMP 10 DIESEL STP ANN ANNULAR SPACE 11 UNL FILL PIPING SUMP 12 UNL FILL ANN ANNULAR SPACE 13 PREM FILL ANN ANNULAR SPACE 14 PREM FILL PIPING SUMP 15 DIESEL FILL PIPING SUMP 16 DIESEL FILL ANN ANNULAR SPACE 17 DIS 9-10 DISPENSER PAN 18 DIS 9-10 ANN ANNULAR SPACE 19 DIS 11-12 DISPENSER PAN 20 DIS 11-12 ANN ANNULAR SPACE 21 UNL STP STP SUMP 22 UNL STP ANN ANNULAR SPACE 23 PREM STP STP SUMP 24 PREM STP ANN ANNULAR SPACE 25 DIS 1-2 DISPENSER PAN 26 DIS 1-2 ANN ANNULAR SPACE 27 DIS 3-4 DISPENSER PAN 28 DIS 3-4 ANN ANNULAR SPACE 29 DIS 5-6 DISPENSER PAN 30 DIS 5-6 ANN ANNULAR SPACE 31 DIS 7-8 DISPENSER PAN 32 DIS 7-8 ANN ANNULAR SPACE I74200 06-13-19 9:19 AM I74300 06-13-19 9:19 AM I74400 06-13-19 9:19 AM I74700 06-13-19 9:19 AM I74800 06-13-19 9:19 AM I74900 06-13-19 9:19 AM I7BC00 06-13-19 9:19 AM I80200 06-13-19 9:19 AM I80300 06-13-19 9:19 AM I80400 06-13-19 9:19 AM I80700 06-13-19 9:19 AM RELAY LABEL DEVICE LABEL 1 87 STP 2 91 STP 3 DIESEL STP 4 OVERFILL ALARM I80900 06-13-19 9:19 AM RELAY ORIENTATION RELAY DESIGNATION ORIENTATION 1 87 STP NORMALLY OPEN 2 91 STP NORMALLY OPEN 3 DIESEL STP NORMALLY OPEN 4 OVERFILL ALARM NORMALLY OPEN I80B00 06-13-19 9:19 AM RELAY TANK ASSIGNMENT RELAY DESIGNATION TANK 1 87 STP 1 2 91 STP 2 3 DIESEL STP 3 4 OVERFILL ALARM NONE I80A00 06-13-19 9:19 AM RELAY TYPE RELAY DESIGNATION TYPE 1 87 STP PUMP CONTROL OUTPUT 2 91 STP PUMP CONTROL OUTPUT 3 DIESEL STP PUMP CONTROL OUTPUT 4 OVERFILL ALARM STANDARD I80C00 06-13-19 9:19 AM I80800 06-13-19 9:19 AM RELAY SETUP REPORT R 1:87 STP TYPE: PUMP CONTROL OUTPUT TANK #: 1 LIQUID SENSOR ALMS L17:FUEL ALARM L19:FUEL ALARM L21:FUEL ALARM L25:FUEL ALARM L27:FUEL ALARM L29:FUEL ALARM L31:FUEL ALARM L17:SENSOR OUT ALARM L19:SENSOR OUT ALARM L21:SENSOR OUT ALARM L25:SENSOR OUT ALARM L27:SENSOR OUT ALARM L29:SENSOR OUT ALARM L31:SENSOR OUT ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD HOSE ALARMS ALL:GROSS COLLECT FAIL ALL:DEGRD COLLECT FAIL R 2:91 STP TYPE: PUMP CONTROL OUTPUT TANK #: 2 LIQUID SENSOR ALMS L17:FUEL ALARM L19:FUEL ALARM L23:FUEL ALARM L25:FUEL ALARM L27:FUEL ALARM L29:FUEL ALARM L31:FUEL ALARM L17:SENSOR OUT ALARM L19:SENSOR OUT ALARM L23:SENSOR OUT ALARM L25:SENSOR OUT ALARM L27:SENSOR OUT ALARM L29:SENSOR OUT ALARM L31:SENSOR OUT ALARM SMARTSENSOR ALARMS s12:HIGH LIQUID ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD HOSE ALARMS ALL:GROSS COLLECT FAIL ALL:DEGRD COLLECT FAIL R 3:DIESEL STP TYPE: PUMP CONTROL OUTPUT TANK #: 3 LIQUID SENSOR ALMS L 9:FUEL ALARM L17:FUEL ALARM L19:FUEL ALARM L25:FUEL ALARM L27:FUEL ALARM L 9:SENSOR OUT ALARM L17:SENSOR OUT ALARM L19:SENSOR OUT ALARM L25:SENSOR OUT ALARM L27:SENSOR OUT ALARM SMARTSENSOR ALARMS s14:HIGH LIQUID ALARM R 4:OVERFILL ALARM TYPE: STANDARD NORMALLY OPEN TANK #: NONE IN-TANK ALARMS ALL:OVERFILL ALARM ALL:HIGH PRODUCT ALARM I79000 06-13-19 9:20 AM EDIM:1 VR:349643-001-B TD:97.10.27.11.25 I79100 06-13-19 9:20 AM I72300 06-13-19 9:20 AM FAIRFAX SHELL MART 5700 AUBURN ST BAKERSFIELD CA 93306 661 873 7730 SMARTSENSOR ASSIGNMENT DEVICE LABEL CATEGORY 01 PRESS DISP 1-2 VAPOR PRESSURE 02 FM DISP 1-2 AIR FLOW METER 03 FM DISP 3-4 AIR FLOW METER 04 FM DISP 5-6 AIR FLOW METER 05 FM DISP 7-8 AIR FLOW METER 06 FM DISP 9-10 AIR FLOW METER 07 FM DISP 11-12 AIR FLOW METER 08 87 PROD UNKNOWN 09 91 VENT UNKNOWN 10 87-91 VAPOR UNKNOWN 11 87 VENT UNKNOWN 12 91 PROD UNKNOWN 13 91 VENT UNKNOWN 14 DIESEL PROD UNKNOWN 15 DIESEL VENT UNKNOWN 16 ATM PRESS UNKNOWN 17 UNKNOWN 18 UNKNOWN 19 UNKNOWN 20 UNKNOWN 21 UNKNOWN 22 UNKNOWN 23 UNKNOWN 24 UNKNOWN 25 UNKNOWN 26 UNKNOWN 27 UNKNOWN 28 UNKNOWN 29 UNKNOWN 30 UNKNOWN 31 UNKNOWN 32 UNKNOWN 33 UNKNOWN 34 UNKNOWN 35 UNKNOWN 36 UNKNOWN 37 UNKNOWN 38 UNKNOWN 39 UNKNOWN 40 UNKNOWN IV4E00 06-13-19 9:20 AM FAIRFAX SHELL MART 5700 AUBURN ST BAKERSFIELD CA 93306 661 873 7730 EVR/ISD SETUP TYPE: VACUUM ASSIST VACUUM ASSIST TYPE: HEALY VAC IV4F00 06-13-19 9:20 AM FAIRFAX SHELL MART 5700 AUBURN ST BAKERSFIELD CA 93306 661 873 7730 NOZZLE A/L RANGE A/L RATIO: 0.95 - 1.15 IV4000 06-13-19 9:20 AM FAIRFAX SHELL MART 5700 AUBURN ST BAKERSFIELD CA 93306 661 873 7730 VAPOR PROCESSOR TYPE NO VAPOR PROCESSOR IV4700 06-13-19 9:20 AM FAIRFAX SHELL MART 5700 AUBURN ST BAKERSFIELD CA 93306 661 873 7730 ASSESSMENT TIME START TIME: 10:00 AM TIME DELAY MINUTES: 1 IV5200 06-13-19 9:20 AM FAIRFAX SHELL MART 5700 AUBURN ST BAKERSFIELD CA 93306 661 873 7730 ACCEPT HIGH ORVR: NO IV4A00 06-13-19 9:20 AM FAIRFAX SHELL MART 5700 AUBURN ST BAKERSFIELD CA 93306 661 873 7730 ISD HOSE TABLE HOSE FP FP AFM HOSE ID ID LABEL ID LABEL 01 01 01 01 BLEND3 02 02 02 01 BLEND3 03 03 03 02 BLEND3 04 04 04 02 BLEND3 05 05 05 03 BLEND3 06 06 06 03 BLEND3 07 07 07 04 BLEND3 08 08 08 04 BLEND3 09 09 09 05 BLEND3 10 16 10 05 BLEND3 11 17 11 06 BLEND3 12 18 12 06 BLEND3 IV4B00 06-13-19 9:20 AM FAIRFAX SHELL MART 5700 AUBURN ST BAKERSFIELD CA 93306 661 873 7730 PRODUCT/HOSE MAP TABLE FP AFID M1/H1 M2/H2 M3/H3 M4/H4 01 01 02/01 01/01 09/01 xx/xx 02 01 02/02 01/02 09/02 xx/xx 03 02 02/03 01/03 09/03 xx/xx 04 02 02/04 01/04 09/04 xx/xx 05 03 02/05 01/05 09/05 xx/xx 06 03 02/06 01/06 09/06 xx/xx 07 04 02/07 01/07 09/07 xx/xx 08 04 02/08 01/08 09/08 xx/xx 09 05 02/09 01/09 09/09 xx/xx 16 05 02/10 01/10 09/10 xx/xx 17 06 02/11 01/11 09/11 xx/xx 18 06 02/12 01/12 09/12 xx/xx IV4900 06-13-19 9:20 AM FAIRFAX SHELL MART 5700 AUBURN ST BAKERSFIELD CA 93306 661 873 7730 LABEL TABLE ID LABEL 01 UNASSIGNED 02 BLEND3 03 REGULAR 04 MID GRADE 05 PREMIUM 06 GOLD 07 BRONZE 08 SILVER 09 BLEND2 10 BLEND4 IV1000 06-13-19 9:20 AM ISD VERSION: 01.01 Fairfax food mart avo before alarm Responses Received: I10200 06-13-19 9:21 AM FAIRFAX SHELL MART 5700 AUBURN ST BAKERSFIELD CA 93306 661 873 7730 SYSTEM CONFIGURATION SLOT BOARD TYPE POWER ON RESET CURRENT 1 8SMARTSENSOR BD 39486 39624 2 7SMARTSENSOR BD 506092 509338 3 UNUSED 4977955 4998784 4 4 PROBE / G.T. 162897 163066 5 INTERSTITIAL BD 201455 202014 6 INTERSTITIAL BD 201370 201741 7 INTERSTITIAL BD 201497 201741 8 INTERSTITIAL BD 201009 201909 9 RELAY BOARD 14935 14942 10 STP SENSE BOARD 33180 33205 11 UNUSED 4973935 4994080 12 UNUSED 4970580 4989978 13 UNUSED 4968677 4986709 14 UNUSED 4968716 4982337 15 UNUSED 4968441 4983923 16 UNUSED 4970266 4986980 COMM 1 ELEC DISP INT. 101034 101095 COMM 2 RS232 SERIAL BD 14974 14962 COMM 3 UNUSED 4972385 4995318 COMM 4 UNUSED 4969187 4988760 COMM 5 UNUSED 4969403 4989069 COMM 6 UNUSED 4970148 4990385 I90200 06-13-19 9:21 AM SOFTWARE REVISION LEVEL VERSION 327.04 SOFTWARE# 346327-100-E CREATED - 07.02.06.10.28 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD PMC I11100 06-13-19 9:21 AM FAIRFAX SHELL MART 5700 AUBURN ST BAKERSFIELD CA 93306 661 873 7730 PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME T 3 TANK DIESEL LOW PRODUCT ALARM ALARM 06-12-19 8:12 PM E 1 OTHER COMMUNICATION ALARM CLEAR 06-10-19 2:55 AM E 1 OTHER COMMUNICATION ALARM ALARM 06-10-19 2:54 AM E 1 OTHER COMMUNICATION ALARM CLEAR 06-03-19 6:21 PM E 1 OTHER COMMUNICATION ALARM ALARM 06-03-19 6:20 PM E 1 OTHER COMMUNICATION ALARM CLEAR 06-03-19 2:55 AM E 1 OTHER COMMUNICATION ALARM ALARM 06-03-19 2:53 AM T 3 TANK DIESEL LOW PRODUCT ALARM CLEAR 06-01-19 8:20 AM T 3 TANK DIESEL LOW PRODUCT ALARM ALARM 05-31-19 5:32 PM E 1 OTHER COMMUNICATION ALARM CLEAR 05-27-19 2:54 AM E 1 OTHER COMMUNICATION ALARM ALARM 05-27-19 2:53 AM L15 PIPE DIESEL FILL FUEL ALARM CLEAR 05-21-19 11:37 AM L11 PIPE UNL FILL FUEL ALARM CLEAR 05-21-19 11:35 AM E 1 OTHER COMMUNICATION ALARM CLEAR 05-20-19 2:54 AM E 1 OTHER COMMUNICATION ALARM ALARM 05-20-19 2:52 AM L11 PIPE UNL FILL FUEL ALARM ALARM 05-18-19 10:19 PM L15 PIPE DIESEL FILL FUEL ALARM ALARM 05-18-19 7:58 PM E 1 OTHER COMMUNICATION ALARM CLEAR 05-13-19 2:54 AM E 1 OTHER COMMUNICATION ALARM ALARM 05-13-19 2:52 AM T 1 TANK UNLEADED LOW PRODUCT ALARM CLEAR 05-09-19 6:59 PM T 1 TANK UNLEADED LOW PRODUCT ALARM ALARM 05-09-19 6:00 PM T 1 TANK UNLEADED LOW PRODUCT ALARM CLEAR 05-06-19 4:03 PM T 1 TANK UNLEADED LOW PRODUCT ALARM ALARM 05-06-19 10:25 AM E 1 OTHER COMMUNICATION ALARM CLEAR 05-06-19 3:52 AM E 1 OTHER COMMUNICATION ALARM ALARM 05-06-19 3:50 AM E 1 OTHER COMMUNICATION ALARM CLEAR 04-29-19 3:51 AM E 1 OTHER COMMUNICATION ALARM ALARM 04-29-19 3:50 AM E 1 OTHER COMMUNICATION ALARM CLEAR 04-22-19 3:51 AM E 1 OTHER COMMUNICATION ALARM ALARM 04-22-19 3:50 AM E 1 OTHER COMMUNICATION ALARM CLEAR 04-15-19 3:52 AM E 1 OTHER COMMUNICATION ALARM ALARM 04-15-19 3:50 AM E 1 OTHER COMMUNICATION ALARM CLEAR 04-08-19 3:52 AM E 1 OTHER COMMUNICATION ALARM ALARM 04-08-19 3:51 AM E 1 OTHER COMMUNICATION ALARM CLEAR 04-01-19 2:52 AM E 1 OTHER COMMUNICATION ALARM ALARM 04-01-19 2:50 AM E 1 OTHER COMMUNICATION ALARM CLEAR 03-25-19 2:52 AM E 1 OTHER COMMUNICATION ALARM ALARM 03-25-19 2:50 AM T 3 TANK DIESEL LOW PRODUCT ALARM CLEAR 03-20-19 1:25 PM T 3 TANK DIESEL LOW PRODUCT ALARM ALARM 03-20-19 6:22 AM E 1 OTHER COMMUNICATION ALARM CLEAR 03-18-19 2:52 AM E 1 OTHER COMMUNICATION ALARM ALARM 03-18-19 2:50 AM E 1 OTHER COMMUNICATION ALARM CLEAR 03-11-19 1:48 AM E 1 OTHER COMMUNICATION ALARM ALARM 03-11-19 1:47 AM E 1 OTHER COMMUNICATION ALARM CLEAR 03-04-19 2:49 AM E 1 OTHER COMMUNICATION ALARM ALARM 03-04-19 2:47 AM E 1 OTHER COMMUNICATION ALARM CLEAR 02-25-19 2:49 AM E 1 OTHER COMMUNICATION ALARM ALARM 02-25-19 2:47 AM E 1 OTHER COMMUNICATION ALARM CLEAR 02-18-19 2:49 AM E 1 OTHER COMMUNICATION ALARM ALARM 02-18-19 2:47 AM T 1 TANK UNLEADED LOW PRODUCT ALARM CLEAR 02-11-19 8:28 PM I11200 06-13-19 9:21 AM FAIRFAX SHELL MART 5700 AUBURN ST BAKERSFIELD CA 93306 661 873 7730 NON-PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME T 2 TANK PREMIUM DELIVERY NEEDED ALARM 06-12-19 9:58 PM T 3 TANK DIESEL DELIVERY NEEDED ALARM 06-12-19 6:11 PM T 3 TANK DIESEL DELIVERY NEEDED CLEAR 06-01-19 8:21 AM T 3 TANK DIESEL DELIVERY NEEDED ALARM 05-31-19 1:16 PM h 8 OTHER FP8: BLEND3 DEGRD COLLECT WARN CLEAR 05-24-19 10:00 AM T 1 TANK UNLEADED DELIVERY NEEDED CLEAR 05-23-19 8:55 PM T 1 TANK UNLEADED DELIVERY NEEDED ALARM 05-23-19 8:26 PM h 8 OTHER FP8: BLEND3 DEGRD COLLECT WARN ALARM 05-23-19 10:03 AM h 8 OTHER FP8: BLEND3 DEGRD COLLECT WARN CLEAR 05-11-19 10:00 AM h 8 OTHER FP8: BLEND3 DEGRD COLLECT WARN ALARM 05-10-19 10:02 AM T 2 TANK PREMIUM DELIVERY NEEDED CLEAR 05-09-19 6:21 PM T 1 TANK UNLEADED DELIVERY NEEDED CLEAR 05-09-19 7:00 PM T 2 TANK PREMIUM DELIVERY NEEDED ALARM 05-09-19 5:29 PM T 1 TANK UNLEADED DELIVERY NEEDED ALARM 05-09-19 2:39 PM T 1 TANK UNLEADED DELIVERY NEEDED CLEAR 05-06-19 4:04 PM T 1 TANK UNLEADED DELIVERY NEEDED ALARM 05-06-19 3:58 AM SYSTEM PRINTER ERROR CLEAR 05-03-19 11:16 AM SYSTEM PAPER OUT CLEAR 05-03-19 11:16 AM SYSTEM PRINTER ERROR ALARM 05-03-19 11:15 AM SYSTEM PAPER OUT ALARM 05-03-19 11:15 AM h11 OTHER FP11: BLEND3 GROSS COLLECT WARN CLEAR 04-29-19 10:00 AM h11 OTHER FP11: BLEND3 GROSS COLLECT WARN ALARM 04-28-19 10:03 AM OTHER ISD VAPOR LEAK WARN CLEAR 04-18-19 2:24 PM OTHER ISD VAPOR LEAK WARN ALARM 04-16-19 10:05 AM h10 OTHER FP10: BLEND3 DEGRD COLLECT WARN CLEAR 04-10-19 10:00 AM h10 OTHER FP10: BLEND3 DEGRD COLLECT WARN ALARM 04-08-19 10:04 AM h10 OTHER FP10: BLEND3 DEGRD COLLECT WARN CLEAR 04-04-19 9:41 AM OTHER ISD GROSS PRES WARN CLEAR 04-04-19 9:41 AM OTHER ISD GROSS PRES WARN ALARM 04-03-19 10:03 AM h10 OTHER FP10: BLEND3 DEGRD COLLECT WARN ALARM 04-01-19 10:03 AM OTHER ISD GROSS PRES WARN CLEAR 03-27-19 12:12 PM h10 OTHER FP10: BLEND3 DEGRD COLLECT WARN CLEAR 03-27-19 10:00 AM h10 OTHER FP10: BLEND3 DEGRD COLLECT WARN ALARM 03-25-19 10:02 AM OTHER ISD GROSS PRES WARN ALARM 03-21-19 10:04 AM T 3 TANK DIESEL DELIVERY NEEDED CLEAR 03-20-19 1:25 PM T 3 TANK DIESEL DELIVERY NEEDED ALARM 03-19-19 5:28 PM h 8 OTHER FP8: BLEND3 DEGRD COLLECT WARN CLEAR 03-18-19 10:00 AM h 8 OTHER FP8: BLEND3 DEGRD COLLECT WARN ALARM 03-17-19 10:05 AM OTHER ISD GROSS PRES WARN CLEAR 03-13-19 10:35 AM SYSTEM PRINTER ERROR CLEAR 03-07-19 3:22 PM SYSTEM PAPER OUT CLEAR 03-07-19 3:22 PM SYSTEM PRINTER ERROR ALARM 03-07-19 3:21 PM SYSTEM PAPER OUT ALARM 03-07-19 3:21 PM OTHER ISD GROSS PRES WARN ALARM 03-07-19 10:02 AM OTHER ISD GROSS PRES WARN CLEAR 03-01-19 9:59 AM T 2 TANK PREMIUM DELIVERY NEEDED CLEAR 02-24-19 6:04 PM T 2 TANK PREMIUM DELIVERY NEEDED ALARM 02-24-19 3:11 PM OTHER ISD GROSS PRES WARN ALARM 02-23-19 10:03 AM OTHER ISD GROSS PRES WARN CLEAR 02-16-19 11:11 AM h11 OTHER FP11: BLEND3 DEGRD COLLECT WARN CLEAR 02-14-19 10:00 AM I20600 06-13-19 9:21 AM FAIRFAX SHELL MART 5700 AUBURN ST BAKERSFIELD CA 93306 661 873 7730 TANK ALARM HISTORY TANK 1 UNLEADED LEAK ALARM 12-01-16 3:32 PM OVERFILL ALARM 11-26-18 10:32 AM 05-10-17 1:24 PM 02-27-13 3:05 PM LOW PRODUCT ALARM 05-09-19 6:00 PM 05-06-19 10:25 AM 02-11-19 6:19 PM SUDDEN LOSS ALARM 06-08-18 7:03 AM 06-08-18 6:53 AM 05-10-18 1:53 PM HIGH PRODUCT ALARM 05-10-18 1:55 PM 05-02-17 10:27 AM 04-20-16 10:31 AM INVALID FUEL LEVEL 02-27-13 3:07 PM PROBE OUT 11-26-18 10:33 AM 11-26-18 10:08 AM 05-10-18 1:55 PM HIGH WATER WARNING 02-06-07 9:58 AM DELIVERY NEEDED 05-23-19 8:26 PM 05-09-19 2:39 PM 05-06-19 3:58 AM MAX PRODUCT ALARM 05-02-17 10:27 AM 02-27-14 1:27 PM LOW TEMP WARNING 05-10-18 1:55 PM TANK 2 PREMIUM LEAK ALARM 12-01-16 5:02 PM OVERFILL ALARM 11-26-18 10:22 AM 06-27-18 2:09 PM 12-22-17 2:29 PM LOW PRODUCT ALARM 01-24-19 8:09 AM 11-26-18 10:24 AM 11-26-18 10:10 AM SUDDEN LOSS ALARM 05-10-18 1:49 PM 05-02-17 10:31 AM HIGH PRODUCT ALARM 05-10-18 1:51 PM 05-02-17 10:34 AM 04-20-16 10:32 AM INVALID FUEL LEVEL 11-26-18 10:23 AM 05-10-18 1:50 PM 02-27-14 1:21 PM PROBE OUT 11-26-18 10:23 AM 11-26-18 10:10 AM 05-10-18 1:51 PM HIGH WATER WARNING 11-26-18 10:16 AM 02-06-07 9:56 AM DELIVERY NEEDED 06-12-19 9:58 PM 05-09-19 5:29 PM 02-24-19 3:11 PM MAX PRODUCT ALARM 05-02-17 10:34 AM 03-12-15 11:33 AM 02-27-14 1:21 PM LOW TEMP WARNING 02-27-14 1:23 PM TANK 3 DIESEL LEAK ALARM 12-01-16 5:32 PM HIGH WATER ALARM 02-06-07 10:01 AM OVERFILL ALARM 11-26-18 10:20 AM 02-20-18 8:18 PM 08-31-17 6:55 PM LOW PRODUCT ALARM 06-12-19 8:12 PM 05-31-19 5:32 PM 03-20-19 6:22 AM SUDDEN LOSS ALARM 05-10-18 1:46 PM 02-06-07 9:55 AM HIGH PRODUCT ALARM 05-10-18 1:47 PM 04-20-16 10:32 AM 03-12-15 11:58 AM INVALID FUEL LEVEL 02-27-14 1:16 PM 02-27-13 2:50 PM PROBE OUT 11-26-18 10:20 AM 11-26-18 10:12 AM 05-10-18 1:47 PM HIGH WATER WARNING 02-06-07 10:01 AM DELIVERY NEEDED 06-12-19 6:11 PM 05-31-19 1:16 PM 03-19-19 5:28 PM MAX PRODUCT ALARM 05-10-18 1:47 PM 03-12-15 11:58 AM 02-27-14 1:16 PM LOW TEMP WARNING 11-26-18 10:14 AM 02-27-14 1:18 PM 02-27-13 2:52 PM I38200 06-13-19 9:22 AM I30200 06-13-19 9:22 AM FAIRFAX SHELL MART 5700 AUBURN ST BAKERSFIELD CA 93306 661 873 7730 LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 UNL TANK ANN 11-26-18 9:24 AM LOW LIQUID ALARM 11-26-18 9:20 AM LOW LIQUID ALARM 08-24-18 5:16 AM HIGH LIQUID ALARM 2 PREM TANK ANN 05-10-18 1:17 PM SENSOR OUT ALARM 05-10-18 12:46 PM HIGH LIQUID ALARM 05-10-18 12:37 PM LOW LIQUID ALARM 3 DIESEL TANK ANN 08-22-18 4:21 PM HIGH LIQUID ALARM 05-10-18 1:18 PM HIGH LIQUID ALARM 05-10-18 1:17 PM SENSOR OUT ALARM 9 DIESEL STP 08-14-18 11:03 AM FUEL ALARM 08-02-18 8:51 AM SENSOR OUT ALARM 08-02-18 8:51 AM FUEL ALARM 10 DIESEL STP ANN 08-16-18 2:15 PM FUEL ALARM 08-16-18 2:15 PM FUEL ALARM 08-16-18 9:38 AM FUEL ALARM 11 UNL FILL 05-18-19 10:19 PM FUEL ALARM 11-26-18 8:59 AM FUEL ALARM 05-10-18 1:18 PM FUEL ALARM 12 UNL FILL ANN 12-19-18 11:06 AM FUEL ALARM 12-19-18 9:46 AM FUEL ALARM 12-17-18 3:20 PM FUEL ALARM 13 PREM FILL ANN 05-10-18 1:18 PM FUEL ALARM 05-10-18 1:16 PM SENSOR OUT ALARM 05-10-18 12:34 PM FUEL ALARM 14 PREM FILL 05-10-18 1:18 PM FUEL ALARM 05-10-18 1:16 PM SENSOR OUT ALARM 05-10-18 12:43 PM FUEL ALARM 15 DIESEL FILL 05-18-19 7:58 PM FUEL ALARM 05-10-18 1:18 PM FUEL ALARM 05-10-18 1:16 PM SENSOR OUT ALARM 16 DIESEL FILL ANN 11-10-18 6:47 AM FUEL ALARM 05-10-18 1:18 PM FUEL ALARM 05-10-18 1:16 PM SENSOR OUT ALARM 17 DIS 9-10 05-10-18 1:16 PM SENSOR OUT ALARM 05-10-18 1:04 PM FUEL ALARM 05-02-17 11:21 AM SENSOR OUT ALARM 18 DIS 9-10 ANN 05-23-18 1:08 PM FUEL ALARM 05-11-18 10:18 AM FUEL ALARM 05-10-18 1:18 PM FUEL ALARM 19 DIS 11-12 05-10-18 1:16 PM SENSOR OUT ALARM 05-10-18 1:03 PM FUEL ALARM 05-02-17 11:21 AM SENSOR OUT ALARM 20 DIS 11-12 ANN 05-10-18 1:18 PM FUEL ALARM 05-10-18 1:16 PM SENSOR OUT ALARM 05-10-18 1:03 PM FUEL ALARM 21 UNL STP 05-10-18 1:16 PM SENSOR OUT ALARM 05-10-18 12:58 PM FUEL ALARM 05-02-17 11:21 AM SENSOR OUT ALARM 22 UNL STP ANN 05-31-18 1:44 PM FUEL ALARM 05-10-18 1:16 PM SENSOR OUT ALARM 05-10-18 12:42 PM FUEL ALARM 23 PREM STP 05-10-18 1:16 PM SENSOR OUT ALARM 05-10-18 12:57 PM FUEL ALARM 05-02-17 11:21 AM SENSOR OUT ALARM 24 PREM STP ANN 07-19-18 2:05 PM FUEL ALARM 05-18-18 10:13 AM FUEL ALARM 05-18-18 9:52 AM FUEL ALARM 25 DIS 1-2 05-10-18 1:16 PM SENSOR OUT ALARM 05-10-18 1:08 PM FUEL ALARM 05-02-17 11:21 AM SENSOR OUT ALARM 26 DIS 1-2 ANN 05-10-18 1:17 PM FUEL ALARM 05-10-18 1:16 PM SENSOR OUT ALARM 05-10-18 1:08 PM FUEL ALARM 27 DIS 3-4 05-10-18 1:16 PM SENSOR OUT ALARM 05-10-18 1:07 PM FUEL ALARM 05-09-18 1:18 PM FUEL ALARM 28 DIS 3-4 ANN 05-10-18 1:17 PM FUEL ALARM 05-10-18 1:16 PM SENSOR OUT ALARM 05-10-18 1:06 PM FUEL ALARM 29 DIS 5-6 05-10-18 1:16 PM SENSOR OUT ALARM 05-10-18 1:06 PM FUEL ALARM 05-02-17 11:21 AM SENSOR OUT ALARM 30 DIS 5-6 ANN 05-16-18 7:51 AM FUEL ALARM 05-10-18 1:18 PM FUEL ALARM 05-10-18 1:16 PM SENSOR OUT ALARM 31 DIS 7-8 05-10-18 1:16 PM SENSOR OUT ALARM 05-10-18 1:05 PM FUEL ALARM 05-02-17 11:21 AM SENSOR OUT ALARM 32 DIS 7-8 ANN 05-10-18 1:18 PM FUEL ALARM 05-10-18 1:16 PM SENSOR OUT ALARM 05-10-18 1:05 PM FUEL ALARM I31600 06-13-19 9:22 AM FAIRFAX SHELL MART 5700 AUBURN ST BAKERSFIELD CA 93306 661 873 7730 SMART SENSOR ALARM HISTORY REPORT SENSOR LOCATION 1 PRESS DISP 1-2 2 FM DISP 1-2 3 FM DISP 3-4 4 FM DISP 5-6 5 FM DISP 7-8 6 FM DISP 9-10 7 FM DISP 11-12 8 87 PROD 01-24-19 4:51 PM VACUUM WARNING 05-12-18 7:22 AM NO VACUUM ALARM 05-10-18 1:38 PM HIGH LIQUID ALARM 9 91 VENT 02-08-19 10:21 AM VACUUM WARNING 01-29-19 1:35 PM NO VACUUM ALARM 01-25-19 3:40 PM VACUUM WARNING 10 87-91 VAPOR 01-24-19 2:45 PM VACUUM WARNING 01-23-19 2:24 PM NO VACUUM ALARM 12-31-18 4:41 AM NO VACUUM ALARM 11 87 VENT 05-10-18 1:40 PM HIGH LIQUID ALARM 05-10-18 1:39 PM NO VACUUM ALARM 02-09-18 5:51 AM NO VACUUM ALARM 12 91 PROD 01-04-19 9:41 PM HIGH LIQUID ALARM 01-04-19 9:36 PM HIGH LIQUID ALARM 01-04-19 9:20 PM HIGH LIQUID ALARM 14 DIESEL PROD 08-09-18 9:50 AM VACUUM WARNING 08-02-18 11:51 AM NO VACUUM ALARM 08-02-18 11:24 AM VACUUM WARNING 15 DIESEL VENT 08-16-18 12:57 PM NO VACUUM ALARM 08-09-18 10:16 AM VACUUM WARNING 08-09-18 8:09 AM NO VACUUM ALARM 16 ATM PRESS I40200 06-13-19 9:22 AM I40300 06-13-19 9:22 AM I34200 06-13-19 9:22 AM I34700 06-13-19 9:22 AM IV0100 06-13-19 9:22 AM FAIRFAX SHELL MART 5700 AUBURN ST BAKERSFIELD CA 93306 661 873 7730 ISD ALARM STATUS REPORT EVR TYPE: VACUUM ASSIST ISD TYPE: 01.01 VAPOR PROCESSOR TYPE: NO VAPOR PROCESSOR OVERALL STATUS :PASS EVR VAPOR COLLECTION :PASS EVR VAPOR CONTAINMENT :PASS ISD MONITOR UP-TIME :100% STAGE I TRANSFERS: 0 of 0 NOTEST EVR/ISD PASS TIME :100% WARNING ALARMS DATE TIME DESCRIPTION READING VALUE 19-05-23 10:03:12 A/L RATIO DEGRADATION FP 8 BLEND3 0.00 19-05-10 10:02:35 A/L RATIO DEGRADATION FP 8 BLEND3 0.79 19-04-28 10:03:50 A/L RATIO GROSS BLOCKAGE FP11 BLEND3 BLKD 19-04-18 10:05:43 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 8.86 19-04-17 10:05:35 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 9.11 19-04-16 10:05:44 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 9.47 19-04-09 10:03:48 A/L RATIO DEGRADATION FP10 BLEND3 0.77 19-04-08 10:04:38 A/L RATIO DEGRADATION FP10 BLEND3 0.77 19-04-03 10:03:01 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.20 19-04-03 10:03:01 A/L RATIO DEGRADATION FP10 BLEND3 1.38 FAILURE ALARMS DATE TIME DESCRIPTION READING VALUE 18-11-09 10:01:46 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.70 18-07-26 10:04:43 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 2.69 18-05-16 10:03:11 A/L RATIO GROSS BLOCKAGE FP 1 BLEND3 BLKD 18-04-24 10:05:04 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 11.99 17-11-30 10:02:43 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.78 17-11-09 10:03:39 A/L RATIO GROSS BLOCKAGE FP 5 BLEND3 2.02 17-11-02 10:04:04 A/L RATIO GROSS BLOCKAGE FP 6 BLEND3 BLKD 17-11-02 10:04:04 A/L RATIO GROSS BLOCKAGE FP 5 BLEND3 BLKD 17-10-22 10:04:04 A/L RATIO GROSS BLOCKAGE FP 7 BLEND3 BLKD 17-09-01 10:04:06 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.85 SHUTDOWN & MISCELLANEOUS EVENTS DATE TIME DESCRIPTION ACTION/NAME 19-05-09 18:12:00 TIME CHANGE DETECTED AT: 19-05-09 19:09:12 19-04-18 14:24:39 CONTAINMENT VAPOR LEAKAGE TEST MANUALLY CLEARED 19-04-07 03:00:00 TIME CHANGE DETECTED AT: 19-04-07 02:00:13 19-04-04 09:41:22 COLLECTION TEST HH10 GRADE TEST MANUALLY CLEARED 19-04-04 09:41:14 CONTAINMENT GROSS & DEGRD TEST MANUALLY CLEARED 19-03-27 12:12:05 CONTAINMENT GROSS & DEGRD TEST MANUALLY CLEARED 19-03-15 10:04:19 READINESS ISD:PP EVR:PP ISD & EVR READY 19-03-14 17:36:29 READINESS ISD:PP EVR:NN EVR READINESS PENDING 19-03-14 17:36:29 ISD STARTUP 19-03-14 17:18:30 ISD SHUTDOWN Fairfax shell mart avo after alarm Responses Received: I10200 06-13-19 12:14 PM FAIRFAX SHELL MART 5700 AUBURN ST BAKERSFIELD CA 93306 661 873 7730 SYSTEM CONFIGURATION SLOT BOARD TYPE POWER ON RESET CURRENT 1 8SMARTSENSOR BD 39486 39457 2 7SMARTSENSOR BD 506092 506374 3 UNUSED 4977955 4951684 4 4 PROBE / G.T. 162897 162572 5 INTERSTITIAL BD 201455 201284 6 INTERSTITIAL BD 201370 201327 7 INTERSTITIAL BD 201497 200791 8 INTERSTITIAL BD 201009 201134 9 RELAY BOARD 14935 14927 10 STP SENSE BOARD 33180 33154 11 UNUSED 4973935 4957708 12 UNUSED 4970580 4954367 13 UNUSED 4968677 4954229 14 UNUSED 4968716 4949622 15 UNUSED 4968441 4950175 16 UNUSED 4970266 4952706 COMM 1 ELEC DISP INT. 101034 100927 COMM 2 RS232 SERIAL BD 14974 14947 COMM 3 UNUSED 4972385 4953912 COMM 4 UNUSED 4969187 4952528 COMM 5 UNUSED 4969403 4951026 COMM 6 UNUSED 4970148 4952271 I90200 06-13-19 12:14 PM SOFTWARE REVISION LEVEL VERSION 327.04 SOFTWARE# 346327-100-E CREATED - 07.02.06.10.28 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD PMC I11100 06-13-19 12:14 PM FAIRFAX SHELL MART 5700 AUBURN ST BAKERSFIELD CA 93306 661 873 7730 PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME L24 ANNULAR PREM STP ANN SENSOR OUT ALARM CLEAR 06-13-19 12:12 PM L 3 ANNULAR DIESEL TANK ANN SENSOR OUT ALARM CLEAR 06-13-19 12:11 PM L 2 ANNULAR PREM TANK ANN SENSOR OUT ALARM CLEAR 06-13-19 12:11 PM L 1 ANNULAR UNL TANK ANN SENSOR OUT ALARM CLEAR 06-13-19 12:11 PM L24 ANNULAR PREM STP ANN SENSOR OUT ALARM ALARM 06-13-19 12:11 PM L16 ANNULAR DIESEL FILL ANN SENSOR OUT ALARM CLEAR 06-13-19 12:11 PM L14 PIPE PREM FILL SENSOR OUT ALARM CLEAR 06-13-19 12:11 PM L12 ANNULAR UNL FILL ANN SENSOR OUT ALARM CLEAR 06-13-19 12:11 PM L11 PIPE UNL FILL SENSOR OUT ALARM CLEAR 06-13-19 12:11 PM L10 ANNULAR DIESEL STP ANN SENSOR OUT ALARM CLEAR 06-13-19 12:11 PM L15 PIPE DIESEL FILL SENSOR OUT ALARM CLEAR 06-13-19 12:11 PM L 9 STP SUMP DIESEL STP SENSOR OUT ALARM CLEAR 06-13-19 12:11 PM L20 ANNULAR DIS 11-12 ANN SENSOR OUT ALARM CLEAR 06-13-19 12:11 PM L13 ANNULAR PREM FILL ANN SENSOR OUT ALARM CLEAR 06-13-19 12:11 PM L19 DISP PAN DIS 11-12 SENSOR OUT ALARM CLEAR 06-13-19 12:11 PM L21 STP SUMP UNL STP SENSOR OUT ALARM CLEAR 06-13-19 12:11 PM L24 ANNULAR PREM STP ANN SENSOR OUT ALARM CLEAR 06-13-19 12:11 PM L23 STP SUMP PREM STP SENSOR OUT ALARM CLEAR 06-13-19 12:11 PM L18 ANNULAR DIS 9-10 ANN SENSOR OUT ALARM CLEAR 06-13-19 12:11 PM L22 ANNULAR UNL STP ANN SENSOR OUT ALARM CLEAR 06-13-19 12:11 PM L17 DISP PAN DIS 9-10 SENSOR OUT ALARM CLEAR 06-13-19 12:10 PM L28 ANNULAR DIS 3-4 ANN SENSOR OUT ALARM CLEAR 06-13-19 12:10 PM L27 DISP PAN DIS 3-4 SENSOR OUT ALARM CLEAR 06-13-19 12:10 PM L30 ANNULAR DIS 5-6 ANN SENSOR OUT ALARM CLEAR 06-13-19 12:10 PM L31 DISP PAN DIS 7-8 SENSOR OUT ALARM CLEAR 06-13-19 12:10 PM L26 ANNULAR DIS 1-2 ANN SENSOR OUT ALARM CLEAR 06-13-19 12:10 PM L25 DISP PAN DIS 1-2 SENSOR OUT ALARM CLEAR 06-13-19 12:10 PM L29 DISP PAN DIS 5-6 SENSOR OUT ALARM CLEAR 06-13-19 12:10 PM L32 ANNULAR DIS 7-8 ANN SENSOR OUT ALARM CLEAR 06-13-19 12:10 PM L16 ANNULAR DIESEL FILL ANN SENSOR OUT ALARM ALARM 06-13-19 12:09 PM L29 DISP PAN DIS 5-6 SENSOR OUT ALARM ALARM 06-13-19 12:09 PM L30 ANNULAR DIS 5-6 ANN SENSOR OUT ALARM ALARM 06-13-19 12:09 PM L28 ANNULAR DIS 3-4 ANN SENSOR OUT ALARM ALARM 06-13-19 12:09 PM L21 STP SUMP UNL STP SENSOR OUT ALARM ALARM 06-13-19 12:09 PM L27 DISP PAN DIS 3-4 SENSOR OUT ALARM ALARM 06-13-19 12:09 PM L22 ANNULAR UNL STP ANN SENSOR OUT ALARM ALARM 06-13-19 12:09 PM L26 ANNULAR DIS 1-2 ANN SENSOR OUT ALARM ALARM 06-13-19 12:09 PM L25 DISP PAN DIS 1-2 SENSOR OUT ALARM ALARM 06-13-19 12:09 PM L20 ANNULAR DIS 11-12 ANN SENSOR OUT ALARM ALARM 06-13-19 12:09 PM L32 ANNULAR DIS 7-8 ANN SENSOR OUT ALARM ALARM 06-13-19 12:09 PM L24 ANNULAR PREM STP ANN SENSOR OUT ALARM ALARM 06-13-19 12:09 PM L19 DISP PAN DIS 11-12 SENSOR OUT ALARM ALARM 06-13-19 12:09 PM L31 DISP PAN DIS 7-8 SENSOR OUT ALARM ALARM 06-13-19 12:09 PM L23 STP SUMP PREM STP SENSOR OUT ALARM ALARM 06-13-19 12:09 PM L18 ANNULAR DIS 9-10 ANN SENSOR OUT ALARM ALARM 06-13-19 12:09 PM L17 DISP PAN DIS 9-10 SENSOR OUT ALARM ALARM 06-13-19 12:09 PM L14 PIPE PREM FILL SENSOR OUT ALARM ALARM 06-13-19 12:09 PM L15 PIPE DIESEL FILL SENSOR OUT ALARM ALARM 06-13-19 12:09 PM L13 ANNULAR PREM FILL ANN SENSOR OUT ALARM ALARM 06-13-19 12:09 PM L12 ANNULAR UNL FILL ANN SENSOR OUT ALARM ALARM 06-13-19 12:09 PM I11200 06-13-19 12:15 PM FAIRFAX SHELL MART 5700 AUBURN ST BAKERSFIELD CA 93306 661 873 7730 NON-PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME T 3 TANK DIESEL HIGH PRODUCT ALARM CLEAR 06-13-19 12:07 PM T 3 TANK DIESEL DELIVERY NEEDED ALARM 06-13-19 12:07 PM T 3 TANK DIESEL HIGH PRODUCT ALARM ALARM 06-13-19 12:07 PM T 3 TANK DIESEL DELIVERY NEEDED CLEAR 06-13-19 12:07 PM T 2 TANK PREMIUM DELIVERY NEEDED ALARM 06-13-19 12:06 PM T 2 TANK PREMIUM DELIVERY NEEDED CLEAR 06-13-19 12:06 PM T 1 TANK UNLEADED HIGH PRODUCT ALARM CLEAR 06-13-19 12:05 PM T 1 TANK UNLEADED HIGH PRODUCT ALARM ALARM 06-13-19 12:05 PM T 1 TANK UNLEADED HIGH PRODUCT ALARM CLEAR 06-13-19 12:04 PM T 1 TANK UNLEADED HIGH PRODUCT ALARM ALARM 06-13-19 12:02 PM T 2 TANK PREMIUM INVALID FUEL LEVEL CLEAR 06-13-19 11:46 AM T 2 TANK PREMIUM INVALID FUEL LEVEL ALARM 06-13-19 11:45 AM T 1 TANK UNLEADED DELIVERY NEEDED CLEAR 06-13-19 11:40 AM T 1 TANK UNLEADED DELIVERY NEEDED ALARM 06-13-19 11:39 AM T 2 TANK PREMIUM DELIVERY NEEDED ALARM 06-12-19 9:58 PM T 3 TANK DIESEL DELIVERY NEEDED ALARM 06-12-19 6:11 PM T 3 TANK DIESEL DELIVERY NEEDED CLEAR 06-01-19 8:21 AM T 3 TANK DIESEL DELIVERY NEEDED ALARM 05-31-19 1:16 PM h 8 OTHER FP8: BLEND3 DEGRD COLLECT WARN CLEAR 05-24-19 10:00 AM T 1 TANK UNLEADED DELIVERY NEEDED CLEAR 05-23-19 8:55 PM T 1 TANK UNLEADED DELIVERY NEEDED ALARM 05-23-19 8:26 PM h 8 OTHER FP8: BLEND3 DEGRD COLLECT WARN ALARM 05-23-19 10:03 AM h 8 OTHER FP8: BLEND3 DEGRD COLLECT WARN CLEAR 05-11-19 10:00 AM h 8 OTHER FP8: BLEND3 DEGRD COLLECT WARN ALARM 05-10-19 10:02 AM T 2 TANK PREMIUM DELIVERY NEEDED CLEAR 05-09-19 6:21 PM T 1 TANK UNLEADED DELIVERY NEEDED CLEAR 05-09-19 7:00 PM T 2 TANK PREMIUM DELIVERY NEEDED ALARM 05-09-19 5:29 PM T 1 TANK UNLEADED DELIVERY NEEDED ALARM 05-09-19 2:39 PM T 1 TANK UNLEADED DELIVERY NEEDED CLEAR 05-06-19 4:04 PM T 1 TANK UNLEADED DELIVERY NEEDED ALARM 05-06-19 3:58 AM SYSTEM PRINTER ERROR CLEAR 05-03-19 11:16 AM SYSTEM PAPER OUT CLEAR 05-03-19 11:16 AM SYSTEM PRINTER ERROR ALARM 05-03-19 11:15 AM SYSTEM PAPER OUT ALARM 05-03-19 11:15 AM h11 OTHER FP11: BLEND3 GROSS COLLECT WARN CLEAR 04-29-19 10:00 AM h11 OTHER FP11: BLEND3 GROSS COLLECT WARN ALARM 04-28-19 10:03 AM OTHER ISD VAPOR LEAK WARN CLEAR 04-18-19 2:24 PM OTHER ISD VAPOR LEAK WARN ALARM 04-16-19 10:05 AM h10 OTHER FP10: BLEND3 DEGRD COLLECT WARN CLEAR 04-10-19 10:00 AM h10 OTHER FP10: BLEND3 DEGRD COLLECT WARN ALARM 04-08-19 10:04 AM h10 OTHER FP10: BLEND3 DEGRD COLLECT WARN CLEAR 04-04-19 9:41 AM OTHER ISD GROSS PRES WARN CLEAR 04-04-19 9:41 AM OTHER ISD GROSS PRES WARN ALARM 04-03-19 10:03 AM h10 OTHER FP10: BLEND3 DEGRD COLLECT WARN ALARM 04-01-19 10:03 AM OTHER ISD GROSS PRES WARN CLEAR 03-27-19 12:12 PM h10 OTHER FP10: BLEND3 DEGRD COLLECT WARN CLEAR 03-27-19 10:00 AM h10 OTHER FP10: BLEND3 DEGRD COLLECT WARN ALARM 03-25-19 10:02 AM OTHER ISD GROSS PRES WARN ALARM 03-21-19 10:04 AM T 3 TANK DIESEL DELIVERY NEEDED CLEAR 03-20-19 1:25 PM T 3 TANK DIESEL DELIVERY NEEDED ALARM 03-19-19 5:28 PM I20600 06-13-19 12:15 PM FAIRFAX SHELL MART 5700 AUBURN ST BAKERSFIELD CA 93306 661 873 7730 TANK ALARM HISTORY TANK 1 UNLEADED LEAK ALARM 12-01-16 3:32 PM OVERFILL ALARM 06-13-19 12:05 PM 06-13-19 12:02 PM 11-26-18 10:32 AM LOW PRODUCT ALARM 06-13-19 11:39 AM 05-09-19 6:00 PM 05-06-19 10:25 AM SUDDEN LOSS ALARM 06-13-19 11:38 AM 06-08-18 7:03 AM 06-08-18 6:53 AM HIGH PRODUCT ALARM 06-13-19 12:05 PM 06-13-19 12:02 PM 05-10-18 1:55 PM INVALID FUEL LEVEL 02-27-13 3:07 PM PROBE OUT 06-13-19 12:03 PM 06-13-19 11:39 AM 11-26-18 10:33 AM HIGH WATER WARNING 02-06-07 9:58 AM DELIVERY NEEDED 06-13-19 11:39 AM 05-23-19 8:26 PM 05-09-19 2:39 PM MAX PRODUCT ALARM 05-02-17 10:27 AM 02-27-14 1:27 PM LOW TEMP WARNING 05-10-18 1:55 PM TANK 2 PREMIUM LEAK ALARM 12-01-16 5:02 PM OVERFILL ALARM 11-26-18 10:22 AM 06-27-18 2:09 PM 12-22-17 2:29 PM LOW PRODUCT ALARM 06-13-19 11:43 AM 01-24-19 8:09 AM 11-26-18 10:24 AM SUDDEN LOSS ALARM 06-13-19 11:43 AM 05-10-18 1:49 PM 05-02-17 10:31 AM HIGH PRODUCT ALARM 05-10-18 1:51 PM 05-02-17 10:34 AM 04-20-16 10:32 AM INVALID FUEL LEVEL 06-13-19 11:45 AM 11-26-18 10:23 AM 05-10-18 1:50 PM PROBE OUT 06-13-19 11:46 AM 06-13-19 11:43 AM 11-26-18 10:23 AM HIGH WATER WARNING 11-26-18 10:16 AM 02-06-07 9:56 AM DELIVERY NEEDED 06-13-19 12:06 PM 06-12-19 9:58 PM 05-09-19 5:29 PM MAX PRODUCT ALARM 05-02-17 10:34 AM 03-12-15 11:33 AM 02-27-14 1:21 PM LOW TEMP WARNING 02-27-14 1:23 PM TANK 3 DIESEL LEAK ALARM 12-01-16 5:32 PM HIGH WATER ALARM 02-06-07 10:01 AM OVERFILL ALARM 11-26-18 10:20 AM 02-20-18 8:18 PM 08-31-17 6:55 PM LOW PRODUCT ALARM 06-13-19 12:07 PM 06-12-19 8:12 PM 05-31-19 5:32 PM SUDDEN LOSS ALARM 06-13-19 11:50 AM 05-10-18 1:46 PM 02-06-07 9:55 AM HIGH PRODUCT ALARM 06-13-19 12:07 PM 05-10-18 1:47 PM 04-20-16 10:32 AM INVALID FUEL LEVEL 02-27-14 1:16 PM 02-27-13 2:50 PM PROBE OUT 06-13-19 11:51 AM 11-26-18 10:20 AM 11-26-18 10:12 AM HIGH WATER WARNING 02-06-07 10:01 AM DELIVERY NEEDED 06-13-19 12:07 PM 06-12-19 6:11 PM 05-31-19 1:16 PM MAX PRODUCT ALARM 05-10-18 1:47 PM 03-12-15 11:58 AM 02-27-14 1:16 PM LOW TEMP WARNING 11-26-18 10:14 AM 02-27-14 1:18 PM 02-27-13 2:52 PM I38200 06-13-19 12:15 PM I30200 06-13-19 12:15 PM FAIRFAX SHELL MART 5700 AUBURN ST BAKERSFIELD CA 93306 661 873 7730 LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 UNL TANK ANN 06-13-19 12:09 PM SENSOR OUT ALARM 06-13-19 11:23 AM HIGH LIQUID ALARM 06-13-19 11:23 AM LOW LIQUID ALARM 2 PREM TANK ANN 06-13-19 12:09 PM SENSOR OUT ALARM 06-13-19 11:22 AM HIGH LIQUID ALARM 06-13-19 11:17 AM LOW LIQUID ALARM 3 DIESEL TANK ANN 06-13-19 12:09 PM SENSOR OUT ALARM 06-13-19 11:22 AM HIGH LIQUID ALARM 06-13-19 11:17 AM LOW LIQUID ALARM 9 DIESEL STP 06-13-19 12:09 PM SENSOR OUT ALARM 06-13-19 11:50 AM SENSOR OUT ALARM 06-13-19 10:31 AM FUEL ALARM 10 DIESEL STP ANN 06-13-19 12:09 PM SENSOR OUT ALARM 06-13-19 10:31 AM FUEL ALARM 08-16-18 2:15 PM FUEL ALARM 11 UNL FILL 06-13-19 12:09 PM SENSOR OUT ALARM 06-13-19 11:22 AM FUEL ALARM 05-18-19 10:19 PM FUEL ALARM 12 UNL FILL ANN 06-13-19 12:09 PM SENSOR OUT ALARM 06-13-19 11:22 AM FUEL ALARM 12-19-18 11:06 AM FUEL ALARM 13 PREM FILL ANN 06-13-19 12:09 PM SENSOR OUT ALARM 06-13-19 11:19 AM FUEL ALARM 05-10-18 1:18 PM FUEL ALARM 14 PREM FILL 06-13-19 12:09 PM SENSOR OUT ALARM 06-13-19 11:21 AM FUEL ALARM 05-10-18 1:18 PM FUEL ALARM 15 DIESEL FILL 06-13-19 12:09 PM SENSOR OUT ALARM 06-13-19 11:18 AM FUEL ALARM 05-18-19 7:58 PM FUEL ALARM 16 DIESEL FILL ANN 06-13-19 12:09 PM SENSOR OUT ALARM 06-13-19 11:18 AM FUEL ALARM 11-10-18 6:47 AM FUEL ALARM 17 DIS 9-10 06-13-19 12:09 PM SENSOR OUT ALARM 06-13-19 11:13 AM FUEL ALARM 05-10-18 1:16 PM SENSOR OUT ALARM 18 DIS 9-10 ANN 06-13-19 12:09 PM SENSOR OUT ALARM 06-13-19 11:13 AM FUEL ALARM 05-23-18 1:08 PM FUEL ALARM 19 DIS 11-12 06-13-19 12:09 PM SENSOR OUT ALARM 06-13-19 11:14 AM FUEL ALARM 05-10-18 1:16 PM SENSOR OUT ALARM 20 DIS 11-12 ANN 06-13-19 12:09 PM SENSOR OUT ALARM 06-13-19 11:14 AM FUEL ALARM 05-10-18 1:18 PM FUEL ALARM 21 UNL STP 06-13-19 12:09 PM SENSOR OUT ALARM 06-13-19 10:57 AM FUEL ALARM 06-13-19 10:47 AM SENSOR OUT ALARM 22 UNL STP ANN 06-13-19 12:09 PM SENSOR OUT ALARM 06-13-19 10:34 AM FUEL ALARM 05-31-18 1:44 PM FUEL ALARM 23 PREM STP 06-13-19 12:09 PM SENSOR OUT ALARM 06-13-19 10:32 AM FUEL ALARM 05-10-18 1:16 PM SENSOR OUT ALARM 24 PREM STP ANN 06-13-19 12:11 PM SENSOR OUT ALARM 06-13-19 12:09 PM SENSOR OUT ALARM 06-13-19 10:32 AM FUEL ALARM 25 DIS 1-2 06-13-19 12:09 PM SENSOR OUT ALARM 06-13-19 11:04 AM FUEL ALARM 05-10-18 1:16 PM SENSOR OUT ALARM 26 DIS 1-2 ANN 06-13-19 12:09 PM SENSOR OUT ALARM 06-13-19 11:05 AM FUEL ALARM 05-10-18 1:17 PM FUEL ALARM 27 DIS 3-4 06-13-19 12:09 PM SENSOR OUT ALARM 06-13-19 11:06 AM FUEL ALARM 05-10-18 1:16 PM SENSOR OUT ALARM 28 DIS 3-4 ANN 06-13-19 12:09 PM SENSOR OUT ALARM 06-13-19 11:06 AM FUEL ALARM 05-10-18 1:17 PM FUEL ALARM 29 DIS 5-6 06-13-19 12:09 PM SENSOR OUT ALARM 06-13-19 11:07 AM FUEL ALARM 05-10-18 1:16 PM SENSOR OUT ALARM 30 DIS 5-6 ANN 06-13-19 12:09 PM SENSOR OUT ALARM 06-13-19 11:07 AM FUEL ALARM 05-16-18 7:51 AM FUEL ALARM 31 DIS 7-8 06-13-19 12:09 PM SENSOR OUT ALARM 06-13-19 11:12 AM FUEL ALARM 05-10-18 1:16 PM SENSOR OUT ALARM 32 DIS 7-8 ANN 06-13-19 12:09 PM SENSOR OUT ALARM 06-13-19 11:08 AM FUEL ALARM 05-10-18 1:18 PM FUEL ALARM I31600 06-13-19 12:15 PM FAIRFAX SHELL MART 5700 AUBURN ST BAKERSFIELD CA 93306 661 873 7730 SMART SENSOR ALARM HISTORY REPORT SENSOR LOCATION 1 PRESS DISP 1-2 2 FM DISP 1-2 3 FM DISP 3-4 4 FM DISP 5-6 5 FM DISP 7-8 6 FM DISP 9-10 7 FM DISP 11-12 8 87 PROD 06-13-19 11:35 AM NO VACUUM ALARM 06-13-19 11:35 AM HIGH LIQUID ALARM 01-24-19 4:51 PM VACUUM WARNING 9 91 VENT 06-13-19 11:40 AM NO VACUUM ALARM 06-13-19 11:40 AM HIGH LIQUID ALARM 02-08-19 10:21 AM VACUUM WARNING 10 87-91 VAPOR 06-13-19 11:36 AM NO VACUUM ALARM 06-13-19 11:35 AM HIGH LIQUID ALARM 01-24-19 2:45 PM VACUUM WARNING 11 87 VENT 06-13-19 11:37 AM NO VACUUM ALARM 06-13-19 11:35 AM HIGH LIQUID ALARM 05-10-18 1:40 PM HIGH LIQUID ALARM 12 91 PROD 06-13-19 11:42 AM HIGH LIQUID ALARM 06-13-19 11:41 AM NO VACUUM ALARM 01-04-19 9:41 PM HIGH LIQUID ALARM 14 DIESEL PROD 06-13-19 11:48 AM NO VACUUM ALARM 06-13-19 11:47 AM HIGH LIQUID ALARM 08-09-18 9:50 AM VACUUM WARNING 15 DIESEL VENT 06-13-19 11:49 AM NO VACUUM ALARM 06-13-19 11:47 AM HIGH LIQUID ALARM 08-16-18 12:57 PM NO VACUUM ALARM 16 ATM PRESS I40200 06-13-19 12:15 PM I40300 06-13-19 12:15 PM I34200 06-13-19 12:15 PM I34700 06-13-19 12:15 PM IV0100 06-13-19 12:15 PM FAIRFAX SHELL MART 5700 AUBURN ST BAKERSFIELD CA 93306 661 873 7730 ISD ALARM STATUS REPORT EVR TYPE: VACUUM ASSIST ISD TYPE: 01.01 VAPOR PROCESSOR TYPE: NO VAPOR PROCESSOR OVERALL STATUS :PASS EVR VAPOR COLLECTION :PASS EVR VAPOR CONTAINMENT :PASS ISD MONITOR UP-TIME :100% STAGE I TRANSFERS: 0 of 0 NOTEST EVR/ISD PASS TIME :100% WARNING ALARMS DATE TIME DESCRIPTION READING VALUE 19-05-23 10:03:12 A/L RATIO DEGRADATION FP 8 BLEND3 0.00 19-05-10 10:02:35 A/L RATIO DEGRADATION FP 8 BLEND3 0.79 19-04-28 10:03:50 A/L RATIO GROSS BLOCKAGE FP11 BLEND3 BLKD 19-04-18 10:05:43 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 8.86 19-04-17 10:05:35 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 9.11 19-04-16 10:05:44 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 9.47 19-04-09 10:03:48 A/L RATIO DEGRADATION FP10 BLEND3 0.77 19-04-08 10:04:38 A/L RATIO DEGRADATION FP10 BLEND3 0.77 19-04-03 10:03:01 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.20 19-04-03 10:03:01 A/L RATIO DEGRADATION FP10 BLEND3 1.38 FAILURE ALARMS DATE TIME DESCRIPTION READING VALUE 18-11-09 10:01:46 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.70 18-07-26 10:04:43 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 2.69 18-05-16 10:03:11 A/L RATIO GROSS BLOCKAGE FP 1 BLEND3 BLKD 18-04-24 10:05:04 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 11.99 17-11-30 10:02:43 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.78 17-11-09 10:03:39 A/L RATIO GROSS BLOCKAGE FP 5 BLEND3 2.02 17-11-02 10:04:04 A/L RATIO GROSS BLOCKAGE FP 6 BLEND3 BLKD 17-11-02 10:04:04 A/L RATIO GROSS BLOCKAGE FP 5 BLEND3 BLKD 17-10-22 10:04:04 A/L RATIO GROSS BLOCKAGE FP 7 BLEND3 BLKD 17-09-01 10:04:06 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.85 SHUTDOWN & MISCELLANEOUS EVENTS DATE TIME DESCRIPTION ACTION/NAME 19-06-13 12:13:17 READINESS ISD:PP EVR:NN EVR READINESS PENDING 19-06-13 12:13:17 ISD STARTUP 19-06-13 12:13:08 ISD SHUTDOWN 19-05-09 18:12:00 TIME CHANGE DETECTED AT: 19-05-09 19:09:12 19-04-18 14:24:39 CONTAINMENT VAPOR LEAKAGE TEST MANUALLY CLEARED 19-04-07 03:00:00 TIME CHANGE DETECTED AT: 19-04-07 02:00:13 19-04-04 09:41:22 COLLECTION TEST HH10 GRADE TEST MANUALLY CLEARED 19-04-04 09:41:14 CONTAINMENT GROSS & DEGRD TEST MANUALLY CLEARED 19-03-27 12:12:05 CONTAINMENT GROSS & DEGRD TEST MANUALLY CLEARED 19-03-15 10:04:19 READINESS ISD:PP EVR:PP ISD & EVR READY &(56 &DOLIRUQLD(QYLURQPHQWDO5HSRUWLQJ6\VWHP,' ,GHQWLILFDWLRQ867 8QGHUJURXQG6WRUDJH7DQN,&& ,QWHUQDWLRQDO&RGH&RXQFLO 81 ZZZXQLGRFVRUJ5HY 81'(5*5281'6725$*(7$1. 63,//&217$,1(57(67,1*5(3257)250 3DJHRI  7\SHRI$FWLRQ,QVWDOODWLRQ7HVW5HSDLU7HVW0RQWK7HVW , )$&,/,7<,1)250$7,21 &(56,''DWHRI6SLOO&RQWDLQHU7HVW %XVLQHVV1DPH(Same as Facility Name or DBA-Doing Business As) %XVLQHVV6LWH$GGUHVV &LW\ =,3&RGH ,, 81'(5*5281'6725$*(7$1.6(59,&(7(&+1,&,$1,1)250$7,21 1DPHRI8676HUYLFH7HFKQLFLDQ3HUIRUPLQJWKH7HVW(Print as shown on the ICC Certification.) 3KRQH &RQWUDFWRU7DQN7HVWHU/LFHQVH ,&&&HUWLILFDWLRQ ,&&&HUWLILFDWLRQ([SLUDWLRQ'DWH 6SLOO&RQWDLQHU7HVWLQJ7UDLQLQJDQG&HUWLILFDWLRQV(List applicable certifications.) ,,, 63,//&217$,1(57(67,1*,1)250$7,21 7HVW0HWKRG8VHG0DQXIDFWXUHU*XLGHOLQHV(Specify) ,QGXVWU\&RGHRU(QJLQHHULQJ6WDQGDUG (Specify) (QJLQHHUHG0HWKRG(Specify) Attach the testing procedures and all documentation required to determine the results.RI$WWDFKHG3DJHV 7$1.,'(By tank number, stored product, etc.) 6SLOO&RQWDLQHU0DQXIDFWXUHU 0HWKRGRI&DWKRGLF3URWHFWLRQ1RQ0HWDOOLF1RQ0HWDOOLF1RQ0HWDOOLF1RQ0HWDOOLF ,VRODWLRQ,VRODWLRQ,VRODWLRQ,VRODWLRQ 2WKHU(Specify in V.)2WKHU(Specify in V.)2WKHU(Specify in V.)2WKHU(Specify in V.) ,QVLGH'LDPHWHURI6SLOO&RQWDLQHU(Inches) 'HSWKRI6SLOO&RQWDLQHU(Inches) 'RHVWKHVSLOOFRQWDLQHUKDYHDJDOORQFDSDFLW\"<HV1R<HV1R<HV1R<HV1R 0HWKRGWR.HHS6SLOO&RQWDLQHU(PSW\'UDLQ9DOYH'UDLQ9DOYH'UDLQ9DOYH'UDLQ9DOYH 2QVLWH3XPS2QVLWH3XPS2QVLWH3XPS2QVLWH3XPS 2WKHU(Specify in V.)2WKHU(Specify in V.)2WKHU(Specify in V.)2WKHU(Specify in V.) ,9 6800$5<2)7(67,1*5(68/76 6SLOO&RQWDLQHU7HVW5HVXOWV3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLO 9 &200(176 Any items marked “Fail” above must be explained in this section. Any additional comments may also be provided here. 9, &(57,),&$7,21%<8676(59,&(7(&+1,&,$1&21'8&7,1*7+,67(67,1* ,KHUHE\FHUWLI\WKDWWKHVSLOOFRQWDLQHUVZHUHWHVWHGLQDFFRUGDQFHZLWK&DOLIRUQLD&RGHRI5HJXODWLRQV7LWOH'LYLVLRQ &KDSWHU6HFWLRQDQGDOOWKHLQIRUPDWLRQFRQWDLQHGKHUHLQLVDFFXUDWH 8676HUYLFH7HFKQLFLDQ6LJQDWXUH If the facility has more components than this form accommodates, additional copies of this page may be attached. Bakersfield 93306 804904 8374998 11/14/2019 OPW 0175366 PEI 1200 1 87 OPW 12.00” 16.00” 91 OPW 12.00” 16.00” Diesel OPW 12.00” 16.00” 91 fill cap was bad replaced with new one Frank Amestoy (800) 339-9930 10157583 6/13/2019 Shell 5700 Auburn Street SWRCB, January 2006 Spill Bucket Testing Report Form This form is intended for use by contractors performing annual testing of UST spill containment structures. The completed form and printouts from tests (if applicable), should be provided to the facility owner/operator for submittal to the local regulatory agency. 1. FACILITY INFORMATION Facility Name: Date of Testing: Facility Address: Facility Contact: Phone: Date Local Agency Was Notified of Testing : Name of Local Agency Inspector (if present during testing): 2. TESTING CONTRACTOR INFORMATION Company Name: Technician Conducting Test: Credentials1: CSLB Contractor ICC Service Tech. SWRCB Tank Tester Other (Specify) __________________ License Number(s): 3. SPILL BUCKET TESTING INFORMATION Test Method Used: Hydrostatic Vacuum Other Test Equipment Used: Equipment Resolution: Identify Spill Bucket (By Tank Number, Stored Product, etc.) 1234 Bucket Installation Type: Direct Bury Contained in Sump Direct Bury Contained in Sump Direct Bury Contained in Sump Direct Bury Contained in Sump Bucket Diameter: Bucket Depth: Wait time between applying vacuum/water and start of test: Test Start Time (TI): Initial Reading (RI): Test End Time (TF): Final Reading (RF): Test Duration (TF –TI): Change in Reading (RF -RI): Pass/Fail Threshold or Criteria: Test Result: Pass Fail Pass Fail Pass Fail Pass Fail Comments –(include information on repairs made prior to testing, and recommended follow-up for failed tests) CERTIFICATION OF TECHNICIAN RESPONSIBLE FOR CONDUCTING THIS TESTING I hereby certify that all the information contained in this report is true, accurate, and in full compliance with legal requirements. Technician’s Signature:________________________________________________ Date:_________________________ 1 State laws and regulations do not currently require testing to be performed by a qualified contractor. However, local requirements may be more stringent. Shell 6/13/2019 5700 Auburn Street Bakersfield 93306 Avo Cholakian (661) 366-5542 6-4-2019 Kris Karns Confidence UST Services, Inc. Frank Amestoy 804904 8374998 Lake test 0.0625” 87 91 Diesel 12.00” 12.00” 12.00” 16.00” 16.00” 16.00” 30 minutes 30 minutes 30 minutes 10:30am 10:30am 10:30am 15.00”15.00” 15.00” 11:30am 11:30am 11:30am 15.00” 15.00” 15.00” 1 hour 1 hour 1 hour 0.00” 0.00” 0.00” 0.0625” 0.0625” 0.0625” 91 fill cap was bad replaced with new one 6/13/2019 ✔✔ ✔ ✔✔✔ ✔✔✔