Loading...
HomeMy WebLinkAboutFMC 2020Appendix VI Underground Storage Tank Monitoring System Certification Form CERS = California Environmental Reporting System, GPH = Gallons Per Hour, ID = Identification, ICC = International Code Council, LLD = Line Leak Detector, NA = Not Applicable, SW = Single- Walled, UDC = Under-Dispenser Containment, UST = Underground Storage Tank, VPH = Vacuum/Pressure/Hydrostatic Page 1 of 6 TYPE OF ACTION ܆܆ Installation ܆ Repair ܆ 12 Month 1. FACILITY INFORMATION CERS ID Certification Date Facility Name Facility Address City ZIP Code 2. SERVICE TECHNICIAN INFORMATION Company Performing the Certification Phone Mailing Address Service Technician Performing Test Contractor/Tank Tester License Number ICC Number ICC Expiration Date 3. TRAINING AND CERTIFICATIONS Manufacturer and Test Equipment Training Certifications Expiration Date 4. CERTIFICATION BY SERVICE TECHNICIAN CONDUCTING TEST I hereby certify that the monitoring system is operational in accordance with California Code of Regulations, title 23, division 3, chapter 16, section 2638; that required supporting documentation is attached; and all information contained herein is accurate. Service Technician Signature Date Total # of Pages 10125616 11/24/2020 Express Gas 928 Flower Street Bakersfield 93305 Confidence UST Services, Inc.(800) 339-9930 16250 Meacham Road, Bakersfield, CA 93314 Jason Woods 804904 8492093 5/6/2021 Veeder-Root C26937 8/8/2021 PHILTITE 1015883711 6/26/2021 11/24/2020 Underground Storage Tank Monitoring System Certification Form Page 2 of 6 5. MONITORING SYSTEM AND PROGRAMMING A separate Monitoring System Certification Form must be prepared for each control panel. Make of Monitoring System Control Panel Model of Monitoring System Control Panel Software Version Installed Attach the post-certification reports if the monitoring system is capable of generating either; ܆܆Monitoring System Set-up ܆܆ Alarm History Report Yes No NA All monitoring equipment is operational per manufacturer’s specifications? ܆܆܆܆ Secondary containment systems are free of damage, debris, or liquid? ܆܆܆܆ Are the audible and visual alarms operational? ܆܆܆܆ All sensors have been: 1) visually inspected for wiring kinks, breaks and residual buildup on floats; and 2) tested for functionality and confirmed operational? ܆܆܆܆܆܆ Are all sensors installed to detect a release at the earliest opportunity in the secondary containment? ܆܆܆܆܆܆ The monitoring system set-up was reviewed, and proper settings confirmed? ܆܆܆܆܆܆ Was the monitoring control panel’s backup battery visually inspected, functionally tested, and confirmed operational? ܆܆܆܆܆܆ Does the flow of fuel stop at the dispenser if a release is detected in the under- dispenser containment? ܆܆܆܆܆܆ Does the turbine automatically shut down if the piping secondary containment monitoring system fails to operate or is electrically disconnected? ܆܆܆܆܆܆ Does the turbine automatically shut down if the piping secondary containment monitoring system detects a release? Which sensors initiate positive shut down? (Check all that apply) ܆ Sump ܆ UDC ܆܆܆܆܆܆ If monitoring system alarms are relayed to a remote monitoring center, is all communication equipment operational? ܆܆܆܆܆܆ Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 Veeder-Root TLS-350 333.06 Underground Storage Tank Monitoring System Certification Form Page 3 of 6 6. SENSOR TESTING RESULTS List only sensors tested on date of this certification. List “Sensor ID” as labeled in system programming. Additional copies of this page may be attached to accommodate all sensors tested. Sensor ID Sensor Model Component(s) Monitored Pass Fail ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 L1 794380-420 87/91 Annular L2 794380-208 87 STP L3 794380-208 87 Fill Sump L4 794380-208 91 STP L5 794380-208 91 Fill Sump L6 794380-208 Dispenser 1/2 L7 794380-208 Dispenser 3/4 L8 794380-208 Dispenser 5/6 L10 794380-208 Dispenser 9/10 L11 794380-208 Dispenser 11/12 L12 794380-208 Dispenser 7/8 Underground Storage Tank Monitoring System Certification Form Page 4 of 6 7. LINE LEAK DETECTOR TESTING ܆܆ Check this box if line leak detectors ARE NOT installed. (Do not complete this section.) Simulated release rate verified: (Check all that apply.) ܆܆ 3 GPH ܆܆ 0.1 GPH ܆܆ 0.2 GPH Yes No NA Has the testing apparatus been properly calibrated? ܆܆ ܆܆ ܆܆ For emergency generator tank systems, does the LLD create an audible and visual alarm when a leak is detected? ܆܆ ܆܆ ܆܆ For mechanical LLDs, does the LLD restrict the flow through the pipe when a release is detected? ܆܆ ܆܆ ܆܆ For electronic LLDs, does the turbine automatically shut off when a release is detected? ܆܆ ܆܆ ܆܆ For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system is disabled or disconnected? ܆܆ ܆܆ ܆܆ For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system malfunctions or fails a tightness test? ܆܆ ܆܆ ܆܆ For electronic LLDs, have all accessible wiring connections been visually inspected for kinks and breaks? ܆܆ ܆܆ ܆܆ Were all items on the equipment manufacturer’s maintenance checklist completed? ܆܆ ܆܆ ܆܆ Were all LLDs confirmed operational within regulatory requirements? ܆܆ ܆܆ ܆܆ LLD ID LLD Model Lines Monitored Pass Fail ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 87 FX1V 87 product line 91 FX1V 91 product line. Underground Storage Tank Monitoring System Certification Form Page 5 of 6 8. IN-TANK GAUGING TESTING ܆܆ Check this box if tank gauging is used only for inventory control. ܆܆ Check this box if NO tank gauging equipment is installed. (Do not complete this section if either box is checked.) Yes No NA All wiring has been: 1) visually inspected for kinks, breaks and proper entry and termination; and 2) tested for ground faults? ܆܆ ܆܆ ܆܆ Were all in-tank gauging probes visually inspected for damage and residue buildup to ensure that floats move freely, functionally tested, and confirmed operational? ܆܆ ܆܆ Was accuracy of system’s product level readings tested? ܆܆ ܆܆ ܆܆ Was accuracy of system’s water level readings tested? ܆܆ ܆܆ ܆܆ Were all probes reinstalled properly? ܆܆ ܆܆ ܆܆ Were all items on the equipment manufacturer’s maintenance checklist completed? ܆܆ ܆܆ ܆܆ Probe ID Probe Model Tanks Monitored Pass Fail ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ 9. COMMENTS Describe all answers marked “No” or “Fail” and proposed remedy. List all monitoring equipment either replaced or repaired. ܆܆ Flowerstreet Market Setup and Alarm History Before. Responses Received: 200 FLOWER ST MINI MART 928 FLOWER ST BAKERSFIELD CA 93305 661-328-0673 NOV 24, 2020 10:09 AM TANK PRODUCT GALLONS INCHES WATER DEG F ULLAGE 1 REGULAR UNL 7357 58.37 0.0 65.4 4670 2 SUPER UNL 2763 39.18 0.0 67.9 5426 I90500 NOV 24, 2020 10:09 AM SOFTWARE REVISION LEVEL VERSION 333.06 SOFTWARE# 346333-100-G CREATED - 14.10.01.16.35 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD/APM I50500 NOV 24, 2020 10:09 AM SYSTEM TYPE AND LANGUAGE FLAG SYSTEM UNITS U.S. SYSTEM LANGUAGE ENGLISH SYSTEM DATE/TIME FORMAT MON DD YYYY HH:MM:SS xM I50201 NOV 24, 2020 10:09 AM SHIFT TIME 1 : 2:00 AM I50202 NOV 24, 2020 10:09 AM SHIFT TIME 2 : DISABLED I50203 NOV 24, 2020 10:09 AM SHIFT TIME 3 : DISABLED I50204 NOV 24, 2020 10:09 AM SHIFT TIME 4 : DISABLED I54600 NOV 24, 2020 10:09 AM TANK PER TST NEEDED WRN: DISABLED I54900 NOV 24, 2020 10:09 AM TANK ANN TST NEEDED WRN: DISABLED I55300 NOV 24, 2020 10:09 AM LINE RE-ENABLE METHOD PASS LINE TEST I55600 NOV 24, 2020 10:09 AM LINE PER TST NEEDED WRN: DISABLED I55900 NOV 24, 2020 10:09 AM LINE ANN TST NEEDED WRN: DISABLED I50D00 NOV 24, 2020 10:09 AM PRINT TC VOLUMES ENABLED I50E00 NOV 24, 2020 10:09 AM TEMP COMPENSATION VALUE (DEG F ): 60.0 I60B00 NOV 24, 2020 10:09 AM STICK HEIGHT OFFSET ENABLE STATUS DISABLED I51400 NOV 24, 2020 10:09 AM H-PROTOCOL DATA FORMAT HEIGHT I51A01 NOV 24, 2020 10:09 AM DAYLIGHT SAVING TIME DISABLED I51B00 NOV 24, 2020 10:09 AM I51600 NOV 24, 2020 10:09 AM RE-DIRECT LOCAL PRINTOUT DISABLED I50400 NOV 24, 2020 10:10 AM 232 SECURITY CODE PORT SECURITY CODE STATUS 1 000000 DISABLED 2 000000 DISABLED 3 000000 DISABLED 4 000000 DISABLED 5 000000 DISABLED 6 000000 DISABLED I21900 NOV 24, 2020 10:10 AM TANK CHART SECURITY DISABLED I5BD00 NOV 24, 2020 10:10 AM CUSTOM ALARM LABELS DISABLED I56000 NOV 24, 2020 10:10 AM MASS/DENSITY DISABLED I88101 NOV 24, 2020 10:10 AM PORT SETTINGS: COMM BOARD : 1 (EDIM ) RS-232 SECURITY CODE : DISABLED I88102 NOV 24, 2020 10:10 AM PORT SETTINGS: COMM BOARD : 2 (RS-232) BAUD RATE : 1200 PARITY : ODD STOP BIT : 1 STOP DATA LENGTH: 7 DATA RS-232 SECURITY CODE : DISABLED I88103 NOV 24, 2020 10:10 AM PORT SETTINGS: COMM BOARD : 3 (S-SAT ) BAUD RATE : 9600 PARITY : NONE STOP BIT : 1 STOP DATA LENGTH: 8 DATA RS-232 SECURITY CODE : DISABLED DTR NORMAL STATE: HIGH I88104 NOV 24, 2020 10:10 AM I88105 NOV 24, 2020 10:10 AM I88106 NOV 24, 2020 10:10 AM I52000 NOV 24, 2020 10:10 AM RECEIVER AUTO DIAL TYPE & START TIME RCVR LOCATION LABEL DIAL TYPE START TIME 1 ON DATE JUN 26, 2015 DISABLED 2 ON DATE JUN 26, 2015 DISABLED 3 ON DATE JUN 26, 2015 DISABLED 4 ON DATE JUN 26, 2015 DISABLED 5 ON DATE JUN 26, 2015 DISABLED 6 ON DATE JUN 26, 2015 DISABLED 7 ON DATE JUN 26, 2015 DISABLED 8 ON DATE JUN 26, 2015 DISABLED I60100 NOV 24, 2020 10:10 AM TANK CONFIGURATION DEVICE LABEL CONFIGURED 1 REGULAR UNL ON 2 SUPER UNL ON 3 OFF 4 OFF I60200 NOV 24, 2020 10:10 AM TANK PRODUCT LABEL TANK PRODUCT LABEL 1 REGULAR UNL 2 SUPER UNL 3 4 I60300 NOV 24, 2020 10:10 AM TANK PRODUCT CODE TANK PRODUCT LABEL 1 REGULAR UNL 1 2 SUPER UNL 2 3 3 4 4 I60900 NOV 24, 2020 10:10 AM TANK THERMAL COEFFICIENT TANK PRODUCT LABEL 1 REGULAR UNL 0.000700 2 SUPER UNL 0.000700 3 0.000000 4 0.000000 I60700 NOV 24, 2020 10:10 AM TANK DIAMETER TANK PRODUCT LABEL INCHES 1 REGULAR UNL 109.00 2 SUPER UNL 109.00 3 0.00 4 0.00 I60A00 NOV 24, 2020 10:10 AM TANK FULL VOLUME TANK PRODUCT LABEL TANK PROFILE GALLONS 1 REGULAR UNL 20 PTS 12027 2 SUPER UNL 20 PTS 8189 3 1 PT 0 4 1 PT 0 I60400 NOV 24, 2020 10:10 AM TANK FULL VOLUME TANK PRODUCT LABEL GALLONS 1 REGULAR UNL 12027 2 SUPER UNL 8189 3 0 4 0 I60500 NOV 24, 2020 10:10 AM TANK 4 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 REGULAR UNL 12027 10372 6531 2759 2 SUPER UNL 8189 6711 4229 1698 3 0 0 0 0 4 0 0 0 0 I60600 NOV 24, 2020 10:10 AM TANK 20 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 REGULAR UNL 12027 11916 11547 11066 10511 10372 9655 9356 8538 7693 6531 5965 5124 4321 3532 2759 2032 1372 795 485 2 SUPER UNL 8189 8089 7850 7520 7141 6711 6259 5770 5269 4751 4229 3699 3180 2667 2175 1698 1258 847 490 198 3 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 I61500 NOV 24, 2020 10:10 AM TANK PRODUCT LABEL METER DATA 1 REGULAR UNL NO 2 SUPER UNL NO 3 NO 4 NO I62F00 NOV 24, 2020 10:10 AM MAG PROBE FLOAT SIZE TANK PRODUCT LABEL FLOAT SIZE: 1 REGULAR UNL 4.0 IN. 2 SUPER UNL 4.0 IN. I62700 NOV 24, 2020 10:10 AM TANK HIGH WATER WARNING LIMIT TANK PRODUCT LABEL INCHES 1 REGULAR UNL 3.0 2 SUPER UNL 3.0 I64200 NOV 24, 2020 10:11 AM WATER ALARM FILTER TANK PRODUCT LABEL 1 REGULAR UNL LOW 2 SUPER UNL LOW I62400 NOV 24, 2020 10:11 AM TANK HIGH WATER LEVEL LIMIT TANK PRODUCT LABEL INCHES 1 REGULAR UNL 2.0 2 SUPER UNL 2.0 I62800 NOV 24, 2020 10:11 AM TANK MAXIMUM VOLUME LIMIT TANK PRODUCT LABEL GALLONS 1 REGULAR UNL 12027 2 SUPER UNL 8189 3 0 4 0 I62300 NOV 24, 2020 10:11 AM TANK OVERFILL LEVEL LIMIT TANK PRODUCT LABEL GALLONS 1 REGULAR UNL 10824 2 SUPER UNL 7370 3 0 4 0 I62200 NOV 24, 2020 10:11 AM TANK HIGH PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 REGULAR UNL 11426 2 SUPER UNL 7780 3 0 4 0 I62900 NOV 24, 2020 10:11 AM TANK DELIVERY REQUIRED LIMIT TANK PRODUCT LABEL GALLONS 1 REGULAR UNL 1203 2 SUPER UNL 819 3 0 4 0 I62100 NOV 24, 2020 10:11 AM TANK LOW PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 REGULAR UNL 222 2 SUPER UNL 400 3 0 4 0 I62600 NOV 24, 2020 10:11 AM TANK LEAK ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 REGULAR UNL 99 2 SUPER UNL 99 3 99 4 99 I62500 NOV 24, 2020 10:11 AM TANK SUDDEN LOSS LIMIT TANK PRODUCT LABEL GALLONS 1 REGULAR UNL 99 2 SUPER UNL 99 3 99 4 99 I60800 NOV 24, 2020 10:11 AM TANK TILT TANK PRODUCT LABEL INCHES 1 REGULAR UNL 0.00 2 SUPER UNL 0.00 3 0.00 4 0.00 I60B00 NOV 24, 2020 10:11 AM STICK HEIGHT OFFSET ENABLE STATUS DISABLED I60C00 NOV 24, 2020 10:11 AM TANK STICK HEIGHT OFFSET TANK PRODUCT LABEL INCHES 1 REGULAR UNL 0.00 2 SUPER UNL 0.00 3 0.00 4 0.00 I61200 NOV 24, 2020 10:11 AM TANK MANIFOLDED PARTNERS TANK PRODUCT LABEL SIPHON MANIFOLDED TANKS LINE MANIFOLDED TANKS 1 REGULAR UNL NONE NONE 2 SUPER UNL NONE NONE 3 NONE NONE 4 NONE NONE I63600 NOV 24, 2020 10:11 AM PERIODIC LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 REGULAR UNL 1202 2 SUPER UNL 818 3 0 4 0 I62A00 NOV 24, 2020 10:11 AM ANNUAL LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 REGULAR UNL 1202 2 SUPER UNL 818 3 0 4 0 I62C00 NOV 24, 2020 10:11 AM TANK PERIODIC TEST TYPE TANK PRODUCT LABEL PERIODIC TEST TYPE 1 REGULAR UNL STANDARD 2 SUPER UNL STANDARD 3 STANDARD 4 STANDARD I62D00 NOV 24, 2020 10:11 AM TANK LEAK TEST FAIL ALARMS TANK PRODUCT LABEL 1 REGULAR UNL GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 2 SUPER UNL GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 3 GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 4 GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED I63100 NOV 24, 2020 10:11 AM TANK LEAK TEST AVERAGING TANK PRODUCT LABEL ANNUAL PERIODIC 1 REGULAR UNL OFF OFF 2 SUPER UNL OFF OFF 3 OFF OFF 4 OFF OFF I63000 NOV 24, 2020 10:11 AM IN-TANK LEAK TEST NOTIFY TANK PRODUCT LABEL TANK TEST NOTIFY: 1 REGULAR UNL OFF 2 SUPER UNL OFF 3 OFF 4 OFF I63200 NOV 24, 2020 10:11 AM TANK TEST SIPHON BREAK TANK PRODUCT LABEL SIPHON BREAK 1 REGULAR UNL OFF 2 SUPER UNL OFF 3 OFF 4 OFF I61000 NOV 24, 2020 10:11 AM TANK DELIVERY DELAY TANK PRODUCT LABEL 1 REGULAR UNL 1 2 SUPER UNL 1 3 1 4 1 I63A00 NOV 24, 2020 10:12 AM LOW LEVEL PUMP THRESHOLD FOR SEQUENTIAL LINE MANIFOLD TANK PRODUCT LABEL PUMP THRESHOLD 1 REGULAR UNL 10.00% 2 SUPER UNL 10.00% 3 10.00% 4 10.00% I61100 NOV 24, 2020 10:12 AM LEAK TEST METHOD - - - - - - - - - - - - TEST ON DATE : ALL TANK OCT 1, 2014 START TIME : DISABLED TEST RATE :0.20 GAL/HR DURATION : 2 HOURS TST EARLY STOP:DISABLED I61300 NOV 24, 2020 10:12 AM CSLD PROBABLITY OF DETECTION I61400 NOV 24, 2020 10:12 AM CSLD CLIMATE FACTOR I61600 NOV 24, 2020 10:12 AM TANK PRODUCT LABEL CAL UPDATE 1 REGULAR UNL IMMEDIATE 2 SUPER UNL IMMEDIATE 3 IMMEDIATE 4 IMMEDIATE I61A00 NOV 24, 2020 10:12 AM IN-TANK LEAK TEST EARLY STOP TANK PRODUCT LABEL TST EARLY STOP: 1 REGULAR UNL DISABLED 2 SUPER UNL DISABLED 3 DISABLED 4 DISABLED I61B00 NOV 24, 2020 10:12 AM IN-TANK LEAK GROSS TEST AUTO-CONFIRM I61C00 NOV 24, 2020 10:12 AM CSLD REPORT ONLY I62B00 NOV 24, 2020 10:12 AM TANK LAST ANNUAL TEST TANK PRODUCT LABEL DATE 1 REGULAR UNL ??? 0, 0 2 SUPER UNL ??? 0, 0 3 ??? 0, 0 4 ??? 0, 0 I63300 NOV 24, 2020 10:12 AM LEAK TEST REPORT FORMAT: NORMAL I63400 NOV 24, 2020 10:12 AM RECONCILIATION WARNING LIMIT TANK PRODUCT LABEL GALLONS 1 REGULAR UNL 0 2 SUPER UNL 0 3 0 4 0 I63500 NOV 24, 2020 10:12 AM RECONCILIATION ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 REGULAR UNL 1 2 SUPER UNL 1 3 1 4 1 I63900 NOV 24, 2020 10:12 AM ACCU CHART END SHAPE FACTOR TANK PRODUCT LABEL 1 REGULAR UNL END FACTOR: NONE 2 SUPER UNL END FACTOR: NONE 3 END FACTOR: NONE 4 END FACTOR: NONE I78000 NOV 24, 2020 10:12 AM I77700 NOV 24, 2020 10:12 AM I77800 NOV 24, 2020 10:12 AM I78C00 NOV 24, 2020 10:12 AM I78300 NOV 24, 2020 10:12 AM I78F00 NOV 24, 2020 10:12 AM I78700 NOV 24, 2020 10:12 AM I70200 NOV 24, 2020 10:12 AM LIQUID LABEL DEVICE LABEL 1 87-91 ANNULAR 2 87 STP 3 87 FILL 4 91 STP 5 91 FILL 6 DISP 1-2 7 DISP 3-4 8 DISP 5-6 9 DISP 7-8 10 DISP 9-10 11 DISP 11-12 12 DISP 7-8 13 14 15 16 I70300 NOV 24, 2020 10:12 AM LIQUID TYPE SENSOR LOCATION TYPE 1 87-91 ANNULAR TRI-STATE (SINGLE FLOAT) 2 87 STP TRI-STATE (SINGLE FLOAT) 3 87 FILL TRI-STATE (SINGLE FLOAT) 4 91 STP TRI-STATE (SINGLE FLOAT) 5 91 FILL TRI-STATE (SINGLE FLOAT) 6 DISP 1-2 TRI-STATE (SINGLE FLOAT) 7 DISP 3-4 TRI-STATE (SINGLE FLOAT) 8 DISP 5-6 TRI-STATE (SINGLE FLOAT) 9 DISP 7-8 TRI-STATE (SINGLE FLOAT) 10 DISP 9-10 TRI-STATE (SINGLE FLOAT) 11 DISP 11-12 TRI-STATE (SINGLE FLOAT) 12 DISP 7-8 TRI-STATE (SINGLE FLOAT) 13 TRI-STATE (SINGLE FLOAT) 14 TRI-STATE (SINGLE FLOAT) 15 TRI-STATE (SINGLE FLOAT) 16 TRI-STATE (SINGLE FLOAT) I70400 NOV 24, 2020 10:12 AM LIQUID CATEGORY SENSOR LOCATION CATEGORY 1 87-91 ANNULAR ANNULAR SPACE 2 87 STP STP SUMP 3 87 FILL PIPING SUMP 4 91 STP STP SUMP 5 91 FILL PIPING SUMP 6 DISP 1-2 DISPENSER PAN 7 DISP 3-4 DISPENSER PAN 8 DISP 5-6 DISPENSER PAN 9 DISP 7-8 DISPENSER PAN 10 DISP 9-10 DISPENSER PAN 11 DISP 11-12 DISPENSER PAN 12 DISP 7-8 DISPENSER PAN 13 OTHER SENSORS 14 OTHER SENSORS 15 OTHER SENSORS 16 OTHER SENSORS I74200 NOV 24, 2020 10:12 AM I74300 NOV 24, 2020 10:12 AM I74400 NOV 24, 2020 10:12 AM I74700 NOV 24, 2020 10:12 AM I74800 NOV 24, 2020 10:12 AM I74900 NOV 24, 2020 10:12 AM I7BC00 NOV 24, 2020 10:12 AM I80200 NOV 24, 2020 10:12 AM I80300 NOV 24, 2020 10:13 AM I80400 NOV 24, 2020 10:13 AM I80700 NOV 24, 2020 10:13 AM RELAY LABEL DEVICE LABEL 1 REGULAR UNL 2 SUPER UNL 3 OVERFILL 4 I80900 NOV 24, 2020 10:13 AM RELAY ORIENTATION RELAY DESIGNATION ORIENTATION 1 REGULAR UNL NORMALLY CLOSED 2 SUPER UNL NORMALLY CLOSED 3 OVERFILL NORMALLY OPEN 4 NORMALLY OPEN I80B00 NOV 24, 2020 10:13 AM RELAY TANK ASSIGNMENT RELAY DESIGNATION TANK 1 REGULAR UNL 1 2 SUPER UNL 2 3 OVERFILL NONE 4 NONE I80A00 NOV 24, 2020 10:13 AM RELAY TYPE RELAY DESIGNATION TYPE 1 REGULAR UNL STANDARD 2 SUPER UNL STANDARD 3 OVERFILL STANDARD 4 STANDARD I80C00 NOV 24, 2020 10:13 AM I80800 NOV 24, 2020 10:13 AM RELAY SETUP REPORT R 1:REGULAR UNL TYPE: STANDARD NORMALLY CLOSED TANK #: 1 IN-TANK ALARMS T 1:LOW PRODUCT ALARM LIQUID SENSOR ALMS L 2:FUEL ALARM L 6:FUEL ALARM L 7:FUEL ALARM L 8:FUEL ALARM L 9:FUEL ALARM L10:FUEL ALARM L11:FUEL ALARM L12:FUEL ALARM L 2:SENSOR OUT ALARM L 6:SENSOR OUT ALARM L 7:SENSOR OUT ALARM L 8:SENSOR OUT ALARM L 9:SENSOR OUT ALARM L10:SENSOR OUT ALARM L11:SENSOR OUT ALARM L12:SENSOR OUT ALARM L 2:SHORT ALARM L 6:SHORT ALARM L 7:SHORT ALARM L 8:SHORT ALARM L 9:SHORT ALARM L10:SHORT ALARM L11:SHORT ALARM L12:SHORT ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD VP PRES FAIL ISD HOSE ALARMS ALL:GROSS COLLECT FAIL ALL:DEGRD COLLECT FAIL ALL:FLOW COLLECT FAIL PMC ALARMS VP EMISSIONS FAIL VP PRESSURE FAIL VP DUTY CYCLE FAIL PMC SETUP FAIL R 2:SUPER UNL TYPE: STANDARD NORMALLY CLOSED TANK #: 2 IN-TANK ALARMS T 2:LOW PRODUCT ALARM LIQUID SENSOR ALMS L 4:FUEL ALARM L 6:FUEL ALARM L 7:FUEL ALARM L 8:FUEL ALARM L 9:FUEL ALARM L10:FUEL ALARM L11:FUEL ALARM L12:FUEL ALARM L 4:SENSOR OUT ALARM L 6:SENSOR OUT ALARM L 7:SENSOR OUT ALARM L 8:SENSOR OUT ALARM L 9:SENSOR OUT ALARM L10:SENSOR OUT ALARM L11:SENSOR OUT ALARM L 4:SHORT ALARM L 5:SHORT ALARM L 6:SHORT ALARM L 7:SHORT ALARM L 8:SHORT ALARM L 9:SHORT ALARM L10:SHORT ALARM L11:SHORT ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD VP PRES FAIL ISD VP STATUS FAIL ISD HOSE ALARMS ALL:GROSS COLLECT FAIL ALL:DEGRD COLLECT FAIL ALL:FLOW COLLECT FAIL PMC ALARMS VP EMISSIONS FAIL VP PRESSURE FAIL VP DUTY CYCLE FAIL R 3:OVERFILL TYPE: STANDARD NORMALLY OPEN TANK #: NONE IN-TANK ALARMS ALL:OVERFILL ALARM ALL:HIGH PRODUCT ALARM R 4: TYPE: STANDARD NORMALLY OPEN TANK #: NONE - NO ALARM ASSIGNMENTS - I79000 NOV 24, 2020 10:13 AM EDIM:1 VR:349643-001-B TD:97.10.27.11.25 I79100 NOV 24, 2020 10:13 AM I72300 NOV 24, 2020 10:13 AM FLOWER ST MINI MART 928 FLOWER ST BAKERSFIELD CA 93305 661-328-0673 SMARTSENSOR ASSIGNMENT DEVICE LABEL CATEGORY 01 VAPOR PRESSUR VAPOR PRESSURE 02 FM 1-2 AIR FLOW METER 03 FM 3-4 AIR FLOW METER 04 FM 5-6 AIR FLOW METER 05 FM 7-8 AIR FLOW METER 06 FM 9-10 AIR FLOW METER 07 FM 11-12 AIR FLOW METER 08 UNKNOWN 09 UNKNOWN 10 UNKNOWN 11 UNKNOWN 12 UNKNOWN 13 UNKNOWN 14 UNKNOWN 15 UNKNOWN 16 UNKNOWN 17 UNKNOWN 18 UNKNOWN 19 UNKNOWN 20 UNKNOWN 21 UNKNOWN 22 UNKNOWN 23 UNKNOWN 24 UNKNOWN 25 UNKNOWN 26 UNKNOWN 27 UNKNOWN 28 UNKNOWN 29 UNKNOWN 30 UNKNOWN 31 UNKNOWN 32 UNKNOWN 33 UNKNOWN 34 UNKNOWN 35 UNKNOWN 36 UNKNOWN 37 UNKNOWN 38 UNKNOWN 39 UNKNOWN 40 UNKNOWN IV4E00 NOV 24, 2020 10:14 AM FLOWER ST MINI MART 928 FLOWER ST BAKERSFIELD CA 93305 661-328-0673 EVR/ISD SETUP TYPE: VACUUM ASSIST VACUUM ASSIST TYPE: HEALY VAC IV4F00 NOV 24, 2020 10:14 AM FLOWER ST MINI MART 928 FLOWER ST BAKERSFIELD CA 93305 661-328-0673 NOZZLE A/L RANGE A/L RATIO: 0.95 - 1.15 IV4000 NOV 24, 2020 10:14 AM FLOWER ST MINI MART 928 FLOWER ST BAKERSFIELD CA 93305 661-328-0673 VAPOR PROCESSOR TYPE NONE IV4700 NOV 24, 2020 10:14 AM FLOWER ST MINI MART 928 FLOWER ST BAKERSFIELD CA 93305 661-328-0673 ASSESSMENT TIME START TIME: 1:15 PM TIME DELAY MINUTES: 1 IV5200 NOV 24, 2020 10:14 AM FLOWER ST MINI MART 928 FLOWER ST BAKERSFIELD CA 93305 661-328-0673 ACCEPT HIGH ORVR: NO IV4A00 NOV 24, 2020 10:14 AM FLOWER ST MINI MART 928 FLOWER ST BAKERSFIELD CA 93305 661-328-0673 ISD HOSE TABLE HOSE FP FP AFM REL HOSE ID ID LABEL ID ID LABEL 01 01 01 01 02 BLEND3 02 02 02 01 02 BLEND3 03 03 03 02 02 BLEND3 04 04 04 02 02 BLEND3 05 05 05 03 02 BLEND3 06 06 06 03 02 BLEND3 07 07 07 04 02 BLEND3 08 08 08 04 02 BLEND3 09 09 09 05 02 BLEND3 10 16 10 05 02 BLEND3 11 17 11 06 02 BLEND3 12 18 12 06 02 BLEND3 IV4B00 NOV 24, 2020 10:14 AM FLOWER ST MINI MART 928 FLOWER ST BAKERSFIELD CA 93305 661-328-0673 PRODUCT/HOSE MAP TABLE FP AFID M1/H1 M2/H2 M3/H3 M4/H4 01 01 02/01 09/01 01/01 xx/xx 02 01 02/02 09/02 01/02 xx/xx 03 02 02/03 09/03 01/03 xx/xx 04 02 02/04 09/04 01/04 xx/xx 05 03 02/05 09/05 01/05 xx/xx 06 03 02/06 09/06 01/06 xx/xx 07 04 02/07 09/07 01/07 xx/xx 08 04 09/08 02/08 01/08 xx/xx 09 05 02/09 09/09 01/09 xx/xx 16 05 02/10 09/10 01/10 xx/xx 17 06 02/11 09/11 01/11 xx/xx 18 06 02/12 09/12 01/12 xx/xx IV4900 NOV 24, 2020 10:14 AM FLOWER ST MINI MART 928 FLOWER ST BAKERSFIELD CA 93305 661-328-0673 LABEL TABLE ID LABEL 01 UNASSIGNED 02 BLEND3 03 REGULAR 04 MID GRADE 05 PREMIUM 06 GOLD 07 BRONZE 08 SILVER 09 BLEND2 10 BLEND4 IV1000 NOV 24, 2020 10:14 AM ISD VERSION: 01.05 Alarm History before Responses Received: 200 FLOWER ST MINI MART 928 FLOWER ST BAKERSFIELD CA 93305 661-328-0673 NOV 24, 2020 10:09 AM TANK PRODUCT GALLONS INCHES WATER DEG F ULLAGE 1 REGULAR UNL 7357 58.37 0.0 65.4 4670 2 SUPER UNL 2763 39.18 0.0 67.9 5426 I90500 NOV 24, 2020 10:09 AM SOFTWARE REVISION LEVEL VERSION 333.06 SOFTWARE# 346333-100-G CREATED - 14.10.01.16.35 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD/APM I50500 NOV 24, 2020 10:09 AM SYSTEM TYPE AND LANGUAGE FLAG SYSTEM UNITS U.S. SYSTEM LANGUAGE ENGLISH SYSTEM DATE/TIME FORMAT MON DD YYYY HH:MM:SS xM I50201 NOV 24, 2020 10:09 AM SHIFT TIME 1 : 2:00 AM I50202 NOV 24, 2020 10:09 AM SHIFT TIME 2 : DISABLED I50203 NOV 24, 2020 10:09 AM SHIFT TIME 3 : DISABLED I50204 NOV 24, 2020 10:09 AM SHIFT TIME 4 : DISABLED I54600 NOV 24, 2020 10:09 AM TANK PER TST NEEDED WRN: DISABLED I54900 NOV 24, 2020 10:09 AM TANK ANN TST NEEDED WRN: DISABLED I55300 NOV 24, 2020 10:09 AM LINE RE-ENABLE METHOD PASS LINE TEST I55600 NOV 24, 2020 10:09 AM LINE PER TST NEEDED WRN: DISABLED I55900 NOV 24, 2020 10:09 AM LINE ANN TST NEEDED WRN: DISABLED I50D00 NOV 24, 2020 10:09 AM PRINT TC VOLUMES ENABLED I50E00 NOV 24, 2020 10:09 AM TEMP COMPENSATION VALUE (DEG F ): 60.0 I60B00 NOV 24, 2020 10:09 AM STICK HEIGHT OFFSET ENABLE STATUS DISABLED I51400 NOV 24, 2020 10:09 AM H-PROTOCOL DATA FORMAT HEIGHT I51A01 NOV 24, 2020 10:09 AM DAYLIGHT SAVING TIME DISABLED I51B00 NOV 24, 2020 10:09 AM I51600 NOV 24, 2020 10:09 AM RE-DIRECT LOCAL PRINTOUT DISABLED I50400 NOV 24, 2020 10:10 AM 232 SECURITY CODE PORT SECURITY CODE STATUS 1 000000 DISABLED 2 000000 DISABLED 3 000000 DISABLED 4 000000 DISABLED 5 000000 DISABLED 6 000000 DISABLED I21900 NOV 24, 2020 10:10 AM TANK CHART SECURITY DISABLED I5BD00 NOV 24, 2020 10:10 AM CUSTOM ALARM LABELS DISABLED I56000 NOV 24, 2020 10:10 AM MASS/DENSITY DISABLED I88101 NOV 24, 2020 10:10 AM PORT SETTINGS: COMM BOARD : 1 (EDIM ) RS-232 SECURITY CODE : DISABLED I88102 NOV 24, 2020 10:10 AM PORT SETTINGS: COMM BOARD : 2 (RS-232) BAUD RATE : 1200 PARITY : ODD STOP BIT : 1 STOP DATA LENGTH: 7 DATA RS-232 SECURITY CODE : DISABLED I88103 NOV 24, 2020 10:10 AM PORT SETTINGS: COMM BOARD : 3 (S-SAT ) BAUD RATE : 9600 PARITY : NONE STOP BIT : 1 STOP DATA LENGTH: 8 DATA RS-232 SECURITY CODE : DISABLED DTR NORMAL STATE: HIGH I88104 NOV 24, 2020 10:10 AM I88105 NOV 24, 2020 10:10 AM I88106 NOV 24, 2020 10:10 AM I52000 NOV 24, 2020 10:10 AM RECEIVER AUTO DIAL TYPE & START TIME RCVR LOCATION LABEL DIAL TYPE START TIME 1 ON DATE JUN 26, 2015 DISABLED 2 ON DATE JUN 26, 2015 DISABLED 3 ON DATE JUN 26, 2015 DISABLED 4 ON DATE JUN 26, 2015 DISABLED 5 ON DATE JUN 26, 2015 DISABLED 6 ON DATE JUN 26, 2015 DISABLED 7 ON DATE JUN 26, 2015 DISABLED 8 ON DATE JUN 26, 2015 DISABLED I60100 NOV 24, 2020 10:10 AM TANK CONFIGURATION DEVICE LABEL CONFIGURED 1 REGULAR UNL ON 2 SUPER UNL ON 3 OFF 4 OFF I60200 NOV 24, 2020 10:10 AM TANK PRODUCT LABEL TANK PRODUCT LABEL 1 REGULAR UNL 2 SUPER UNL 3 4 I60300 NOV 24, 2020 10:10 AM TANK PRODUCT CODE TANK PRODUCT LABEL 1 REGULAR UNL 1 2 SUPER UNL 2 3 3 4 4 I60900 NOV 24, 2020 10:10 AM TANK THERMAL COEFFICIENT TANK PRODUCT LABEL 1 REGULAR UNL 0.000700 2 SUPER UNL 0.000700 3 0.000000 4 0.000000 I60700 NOV 24, 2020 10:10 AM TANK DIAMETER TANK PRODUCT LABEL INCHES 1 REGULAR UNL 109.00 2 SUPER UNL 109.00 3 0.00 4 0.00 I60A00 NOV 24, 2020 10:10 AM TANK FULL VOLUME TANK PRODUCT LABEL TANK PROFILE GALLONS 1 REGULAR UNL 20 PTS 12027 2 SUPER UNL 20 PTS 8189 3 1 PT 0 4 1 PT 0 I60400 NOV 24, 2020 10:10 AM TANK FULL VOLUME TANK PRODUCT LABEL GALLONS 1 REGULAR UNL 12027 2 SUPER UNL 8189 3 0 4 0 I60500 NOV 24, 2020 10:10 AM TANK 4 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 REGULAR UNL 12027 10372 6531 2759 2 SUPER UNL 8189 6711 4229 1698 3 0 0 0 0 4 0 0 0 0 I60600 NOV 24, 2020 10:10 AM TANK 20 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 REGULAR UNL 12027 11916 11547 11066 10511 10372 9655 9356 8538 7693 6531 5965 5124 4321 3532 2759 2032 1372 795 485 2 SUPER UNL 8189 8089 7850 7520 7141 6711 6259 5770 5269 4751 4229 3699 3180 2667 2175 1698 1258 847 490 198 3 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 I61500 NOV 24, 2020 10:10 AM TANK PRODUCT LABEL METER DATA 1 REGULAR UNL NO 2 SUPER UNL NO 3 NO 4 NO I62F00 NOV 24, 2020 10:10 AM MAG PROBE FLOAT SIZE TANK PRODUCT LABEL FLOAT SIZE: 1 REGULAR UNL 4.0 IN. 2 SUPER UNL 4.0 IN. I62700 NOV 24, 2020 10:10 AM TANK HIGH WATER WARNING LIMIT TANK PRODUCT LABEL INCHES 1 REGULAR UNL 3.0 2 SUPER UNL 3.0 I64200 NOV 24, 2020 10:11 AM WATER ALARM FILTER TANK PRODUCT LABEL 1 REGULAR UNL LOW 2 SUPER UNL LOW I62400 NOV 24, 2020 10:11 AM TANK HIGH WATER LEVEL LIMIT TANK PRODUCT LABEL INCHES 1 REGULAR UNL 2.0 2 SUPER UNL 2.0 I62800 NOV 24, 2020 10:11 AM TANK MAXIMUM VOLUME LIMIT TANK PRODUCT LABEL GALLONS 1 REGULAR UNL 12027 2 SUPER UNL 8189 3 0 4 0 I62300 NOV 24, 2020 10:11 AM TANK OVERFILL LEVEL LIMIT TANK PRODUCT LABEL GALLONS 1 REGULAR UNL 10824 2 SUPER UNL 7370 3 0 4 0 I62200 NOV 24, 2020 10:11 AM TANK HIGH PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 REGULAR UNL 11426 2 SUPER UNL 7780 3 0 4 0 I62900 NOV 24, 2020 10:11 AM TANK DELIVERY REQUIRED LIMIT TANK PRODUCT LABEL GALLONS 1 REGULAR UNL 1203 2 SUPER UNL 819 3 0 4 0 I62100 NOV 24, 2020 10:11 AM TANK LOW PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 REGULAR UNL 222 2 SUPER UNL 400 3 0 4 0 I62600 NOV 24, 2020 10:11 AM TANK LEAK ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 REGULAR UNL 99 2 SUPER UNL 99 3 99 4 99 I62500 NOV 24, 2020 10:11 AM TANK SUDDEN LOSS LIMIT TANK PRODUCT LABEL GALLONS 1 REGULAR UNL 99 2 SUPER UNL 99 3 99 4 99 I60800 NOV 24, 2020 10:11 AM TANK TILT TANK PRODUCT LABEL INCHES 1 REGULAR UNL 0.00 2 SUPER UNL 0.00 3 0.00 4 0.00 I60B00 NOV 24, 2020 10:11 AM STICK HEIGHT OFFSET ENABLE STATUS DISABLED I60C00 NOV 24, 2020 10:11 AM TANK STICK HEIGHT OFFSET TANK PRODUCT LABEL INCHES 1 REGULAR UNL 0.00 2 SUPER UNL 0.00 3 0.00 4 0.00 I61200 NOV 24, 2020 10:11 AM TANK MANIFOLDED PARTNERS TANK PRODUCT LABEL SIPHON MANIFOLDED TANKS LINE MANIFOLDED TANKS 1 REGULAR UNL NONE NONE 2 SUPER UNL NONE NONE 3 NONE NONE 4 NONE NONE I63600 NOV 24, 2020 10:11 AM PERIODIC LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 REGULAR UNL 1202 2 SUPER UNL 818 3 0 4 0 I62A00 NOV 24, 2020 10:11 AM ANNUAL LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 REGULAR UNL 1202 2 SUPER UNL 818 3 0 4 0 I62C00 NOV 24, 2020 10:11 AM TANK PERIODIC TEST TYPE TANK PRODUCT LABEL PERIODIC TEST TYPE 1 REGULAR UNL STANDARD 2 SUPER UNL STANDARD 3 STANDARD 4 STANDARD I62D00 NOV 24, 2020 10:11 AM TANK LEAK TEST FAIL ALARMS TANK PRODUCT LABEL 1 REGULAR UNL GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 2 SUPER UNL GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 3 GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 4 GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED I63100 NOV 24, 2020 10:11 AM TANK LEAK TEST AVERAGING TANK PRODUCT LABEL ANNUAL PERIODIC 1 REGULAR UNL OFF OFF 2 SUPER UNL OFF OFF 3 OFF OFF 4 OFF OFF I63000 NOV 24, 2020 10:11 AM IN-TANK LEAK TEST NOTIFY TANK PRODUCT LABEL TANK TEST NOTIFY: 1 REGULAR UNL OFF 2 SUPER UNL OFF 3 OFF 4 OFF I63200 NOV 24, 2020 10:11 AM TANK TEST SIPHON BREAK TANK PRODUCT LABEL SIPHON BREAK 1 REGULAR UNL OFF 2 SUPER UNL OFF 3 OFF 4 OFF I61000 NOV 24, 2020 10:11 AM TANK DELIVERY DELAY TANK PRODUCT LABEL 1 REGULAR UNL 1 2 SUPER UNL 1 3 1 4 1 I63A00 NOV 24, 2020 10:12 AM LOW LEVEL PUMP THRESHOLD FOR SEQUENTIAL LINE MANIFOLD TANK PRODUCT LABEL PUMP THRESHOLD 1 REGULAR UNL 10.00% 2 SUPER UNL 10.00% 3 10.00% 4 10.00% I61100 NOV 24, 2020 10:12 AM LEAK TEST METHOD - - - - - - - - - - - - TEST ON DATE : ALL TANK OCT 1, 2014 START TIME : DISABLED TEST RATE :0.20 GAL/HR DURATION : 2 HOURS TST EARLY STOP:DISABLED I61300 NOV 24, 2020 10:12 AM CSLD PROBABLITY OF DETECTION I61400 NOV 24, 2020 10:12 AM CSLD CLIMATE FACTOR I61600 NOV 24, 2020 10:12 AM TANK PRODUCT LABEL CAL UPDATE 1 REGULAR UNL IMMEDIATE 2 SUPER UNL IMMEDIATE 3 IMMEDIATE 4 IMMEDIATE I61A00 NOV 24, 2020 10:12 AM IN-TANK LEAK TEST EARLY STOP TANK PRODUCT LABEL TST EARLY STOP: 1 REGULAR UNL DISABLED 2 SUPER UNL DISABLED 3 DISABLED 4 DISABLED I61B00 NOV 24, 2020 10:12 AM IN-TANK LEAK GROSS TEST AUTO-CONFIRM I61C00 NOV 24, 2020 10:12 AM CSLD REPORT ONLY I62B00 NOV 24, 2020 10:12 AM TANK LAST ANNUAL TEST TANK PRODUCT LABEL DATE 1 REGULAR UNL ??? 0, 0 2 SUPER UNL ??? 0, 0 3 ??? 0, 0 4 ??? 0, 0 I63300 NOV 24, 2020 10:12 AM LEAK TEST REPORT FORMAT: NORMAL I63400 NOV 24, 2020 10:12 AM RECONCILIATION WARNING LIMIT TANK PRODUCT LABEL GALLONS 1 REGULAR UNL 0 2 SUPER UNL 0 3 0 4 0 I63500 NOV 24, 2020 10:12 AM RECONCILIATION ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 REGULAR UNL 1 2 SUPER UNL 1 3 1 4 1 I63900 NOV 24, 2020 10:12 AM ACCU CHART END SHAPE FACTOR TANK PRODUCT LABEL 1 REGULAR UNL END FACTOR: NONE 2 SUPER UNL END FACTOR: NONE 3 END FACTOR: NONE 4 END FACTOR: NONE I78000 NOV 24, 2020 10:12 AM I77700 NOV 24, 2020 10:12 AM I77800 NOV 24, 2020 10:12 AM I78C00 NOV 24, 2020 10:12 AM I78300 NOV 24, 2020 10:12 AM I78F00 NOV 24, 2020 10:12 AM I78700 NOV 24, 2020 10:12 AM I70200 NOV 24, 2020 10:12 AM LIQUID LABEL DEVICE LABEL 1 87-91 ANNULAR 2 87 STP 3 87 FILL 4 91 STP 5 91 FILL 6 DISP 1-2 7 DISP 3-4 8 DISP 5-6 9 DISP 7-8 10 DISP 9-10 11 DISP 11-12 12 DISP 7-8 13 14 15 16 I70300 NOV 24, 2020 10:12 AM LIQUID TYPE SENSOR LOCATION TYPE 1 87-91 ANNULAR TRI-STATE (SINGLE FLOAT) 2 87 STP TRI-STATE (SINGLE FLOAT) 3 87 FILL TRI-STATE (SINGLE FLOAT) 4 91 STP TRI-STATE (SINGLE FLOAT) 5 91 FILL TRI-STATE (SINGLE FLOAT) 6 DISP 1-2 TRI-STATE (SINGLE FLOAT) 7 DISP 3-4 TRI-STATE (SINGLE FLOAT) 8 DISP 5-6 TRI-STATE (SINGLE FLOAT) 9 DISP 7-8 TRI-STATE (SINGLE FLOAT) 10 DISP 9-10 TRI-STATE (SINGLE FLOAT) 11 DISP 11-12 TRI-STATE (SINGLE FLOAT) 12 DISP 7-8 TRI-STATE (SINGLE FLOAT) 13 TRI-STATE (SINGLE FLOAT) 14 TRI-STATE (SINGLE FLOAT) 15 TRI-STATE (SINGLE FLOAT) 16 TRI-STATE (SINGLE FLOAT) I70400 NOV 24, 2020 10:12 AM LIQUID CATEGORY SENSOR LOCATION CATEGORY 1 87-91 ANNULAR ANNULAR SPACE 2 87 STP STP SUMP 3 87 FILL PIPING SUMP 4 91 STP STP SUMP 5 91 FILL PIPING SUMP 6 DISP 1-2 DISPENSER PAN 7 DISP 3-4 DISPENSER PAN 8 DISP 5-6 DISPENSER PAN 9 DISP 7-8 DISPENSER PAN 10 DISP 9-10 DISPENSER PAN 11 DISP 11-12 DISPENSER PAN 12 DISP 7-8 DISPENSER PAN 13 OTHER SENSORS 14 OTHER SENSORS 15 OTHER SENSORS 16 OTHER SENSORS I74200 NOV 24, 2020 10:12 AM I74300 NOV 24, 2020 10:12 AM I74400 NOV 24, 2020 10:12 AM I74700 NOV 24, 2020 10:12 AM I74800 NOV 24, 2020 10:12 AM I74900 NOV 24, 2020 10:12 AM I7BC00 NOV 24, 2020 10:12 AM I80200 NOV 24, 2020 10:12 AM I80300 NOV 24, 2020 10:13 AM I80400 NOV 24, 2020 10:13 AM I80700 NOV 24, 2020 10:13 AM RELAY LABEL DEVICE LABEL 1 REGULAR UNL 2 SUPER UNL 3 OVERFILL 4 I80900 NOV 24, 2020 10:13 AM RELAY ORIENTATION RELAY DESIGNATION ORIENTATION 1 REGULAR UNL NORMALLY CLOSED 2 SUPER UNL NORMALLY CLOSED 3 OVERFILL NORMALLY OPEN 4 NORMALLY OPEN I80B00 NOV 24, 2020 10:13 AM RELAY TANK ASSIGNMENT RELAY DESIGNATION TANK 1 REGULAR UNL 1 2 SUPER UNL 2 3 OVERFILL NONE 4 NONE I80A00 NOV 24, 2020 10:13 AM RELAY TYPE RELAY DESIGNATION TYPE 1 REGULAR UNL STANDARD 2 SUPER UNL STANDARD 3 OVERFILL STANDARD 4 STANDARD I80C00 NOV 24, 2020 10:13 AM I80800 NOV 24, 2020 10:13 AM RELAY SETUP REPORT R 1:REGULAR UNL TYPE: STANDARD NORMALLY CLOSED TANK #: 1 IN-TANK ALARMS T 1:LOW PRODUCT ALARM LIQUID SENSOR ALMS L 2:FUEL ALARM L 6:FUEL ALARM L 7:FUEL ALARM L 8:FUEL ALARM L 9:FUEL ALARM L10:FUEL ALARM L11:FUEL ALARM L12:FUEL ALARM L 2:SENSOR OUT ALARM L 6:SENSOR OUT ALARM L 7:SENSOR OUT ALARM L 8:SENSOR OUT ALARM L 9:SENSOR OUT ALARM L10:SENSOR OUT ALARM L11:SENSOR OUT ALARM L12:SENSOR OUT ALARM L 2:SHORT ALARM L 6:SHORT ALARM L 7:SHORT ALARM L 8:SHORT ALARM L 9:SHORT ALARM L10:SHORT ALARM L11:SHORT ALARM L12:SHORT ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD VP PRES FAIL ISD HOSE ALARMS ALL:GROSS COLLECT FAIL ALL:DEGRD COLLECT FAIL ALL:FLOW COLLECT FAIL PMC ALARMS VP EMISSIONS FAIL VP PRESSURE FAIL VP DUTY CYCLE FAIL PMC SETUP FAIL R 2:SUPER UNL TYPE: STANDARD NORMALLY CLOSED TANK #: 2 IN-TANK ALARMS T 2:LOW PRODUCT ALARM LIQUID SENSOR ALMS L 4:FUEL ALARM L 6:FUEL ALARM L 7:FUEL ALARM L 8:FUEL ALARM L 9:FUEL ALARM L10:FUEL ALARM L11:FUEL ALARM L12:FUEL ALARM L 4:SENSOR OUT ALARM L 6:SENSOR OUT ALARM L 7:SENSOR OUT ALARM L 8:SENSOR OUT ALARM L 9:SENSOR OUT ALARM L10:SENSOR OUT ALARM L11:SENSOR OUT ALARM L 4:SHORT ALARM L 5:SHORT ALARM L 6:SHORT ALARM L 7:SHORT ALARM L 8:SHORT ALARM L 9:SHORT ALARM L10:SHORT ALARM L11:SHORT ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD VP PRES FAIL ISD VP STATUS FAIL ISD HOSE ALARMS ALL:GROSS COLLECT FAIL ALL:DEGRD COLLECT FAIL ALL:FLOW COLLECT FAIL PMC ALARMS VP EMISSIONS FAIL VP PRESSURE FAIL VP DUTY CYCLE FAIL R 3:OVERFILL TYPE: STANDARD NORMALLY OPEN TANK #: NONE IN-TANK ALARMS ALL:OVERFILL ALARM ALL:HIGH PRODUCT ALARM R 4: TYPE: STANDARD NORMALLY OPEN TANK #: NONE - NO ALARM ASSIGNMENTS - I79000 NOV 24, 2020 10:13 AM EDIM:1 VR:349643-001-B TD:97.10.27.11.25 I79100 NOV 24, 2020 10:13 AM I72300 NOV 24, 2020 10:13 AM FLOWER ST MINI MART 928 FLOWER ST BAKERSFIELD CA 93305 661-328-0673 SMARTSENSOR ASSIGNMENT DEVICE LABEL CATEGORY 01 VAPOR PRESSUR VAPOR PRESSURE 02 FM 1-2 AIR FLOW METER 03 FM 3-4 AIR FLOW METER 04 FM 5-6 AIR FLOW METER 05 FM 7-8 AIR FLOW METER 06 FM 9-10 AIR FLOW METER 07 FM 11-12 AIR FLOW METER 08 UNKNOWN 09 UNKNOWN 10 UNKNOWN 11 UNKNOWN 12 UNKNOWN 13 UNKNOWN 14 UNKNOWN 15 UNKNOWN 16 UNKNOWN 17 UNKNOWN 18 UNKNOWN 19 UNKNOWN 20 UNKNOWN 21 UNKNOWN 22 UNKNOWN 23 UNKNOWN 24 UNKNOWN 25 UNKNOWN 26 UNKNOWN 27 UNKNOWN 28 UNKNOWN 29 UNKNOWN 30 UNKNOWN 31 UNKNOWN 32 UNKNOWN 33 UNKNOWN 34 UNKNOWN 35 UNKNOWN 36 UNKNOWN 37 UNKNOWN 38 UNKNOWN 39 UNKNOWN 40 UNKNOWN IV4E00 NOV 24, 2020 10:14 AM FLOWER ST MINI MART 928 FLOWER ST BAKERSFIELD CA 93305 661-328-0673 EVR/ISD SETUP TYPE: VACUUM ASSIST VACUUM ASSIST TYPE: HEALY VAC IV4F00 NOV 24, 2020 10:14 AM FLOWER ST MINI MART 928 FLOWER ST BAKERSFIELD CA 93305 661-328-0673 NOZZLE A/L RANGE A/L RATIO: 0.95 - 1.15 IV4000 NOV 24, 2020 10:14 AM FLOWER ST MINI MART 928 FLOWER ST BAKERSFIELD CA 93305 661-328-0673 VAPOR PROCESSOR TYPE NONE IV4700 NOV 24, 2020 10:14 AM FLOWER ST MINI MART 928 FLOWER ST BAKERSFIELD CA 93305 661-328-0673 ASSESSMENT TIME START TIME: 1:15 PM TIME DELAY MINUTES: 1 IV5200 NOV 24, 2020 10:14 AM FLOWER ST MINI MART 928 FLOWER ST BAKERSFIELD CA 93305 661-328-0673 ACCEPT HIGH ORVR: NO IV4A00 NOV 24, 2020 10:14 AM FLOWER ST MINI MART 928 FLOWER ST BAKERSFIELD CA 93305 661-328-0673 ISD HOSE TABLE HOSE FP FP AFM REL HOSE ID ID LABEL ID ID LABEL 01 01 01 01 02 BLEND3 02 02 02 01 02 BLEND3 03 03 03 02 02 BLEND3 04 04 04 02 02 BLEND3 05 05 05 03 02 BLEND3 06 06 06 03 02 BLEND3 07 07 07 04 02 BLEND3 08 08 08 04 02 BLEND3 09 09 09 05 02 BLEND3 10 16 10 05 02 BLEND3 11 17 11 06 02 BLEND3 12 18 12 06 02 BLEND3 IV4B00 NOV 24, 2020 10:14 AM FLOWER ST MINI MART 928 FLOWER ST BAKERSFIELD CA 93305 661-328-0673 PRODUCT/HOSE MAP TABLE FP AFID M1/H1 M2/H2 M3/H3 M4/H4 01 01 02/01 09/01 01/01 xx/xx 02 01 02/02 09/02 01/02 xx/xx 03 02 02/03 09/03 01/03 xx/xx 04 02 02/04 09/04 01/04 xx/xx 05 03 02/05 09/05 01/05 xx/xx 06 03 02/06 09/06 01/06 xx/xx 07 04 02/07 09/07 01/07 xx/xx 08 04 09/08 02/08 01/08 xx/xx 09 05 02/09 09/09 01/09 xx/xx 16 05 02/10 09/10 01/10 xx/xx 17 06 02/11 09/11 01/11 xx/xx 18 06 02/12 09/12 01/12 xx/xx IV4900 NOV 24, 2020 10:14 AM FLOWER ST MINI MART 928 FLOWER ST BAKERSFIELD CA 93305 661-328-0673 LABEL TABLE ID LABEL 01 UNASSIGNED 02 BLEND3 03 REGULAR 04 MID GRADE 05 PREMIUM 06 GOLD 07 BRONZE 08 SILVER 09 BLEND2 10 BLEND4 IV1000 NOV 24, 2020 10:14 AM ISD VERSION: 01.05 Flower Street Market Alarm History After. Responses Received: I10200 NOV 24, 2020 2:07 PM FLOWER ST MINI MART 928 FLOWER ST BAKERSFIELD CA 93305 661-328-0673 SYSTEM CONFIGURATION SLOT BOARD TYPE POWER ON RESET CURRENT 1 UNUSED 10457924 10318474 2 UNUSED 10331431 10294099 3 UNUSED 10312623 10288427 4 8SMARTSENSOR BD 39519 39563 5 4 PROBE / G.T. 163572 163539 6 INTERSTITIAL BD 201659 201450 7 INTERSTITIAL BD 201747 201701 8 UNUSED 10331048 10292939 9 UNUSED 10314410 10294464 10 RELAY BOARD 14965 15000 11 UNUSED 10317088 10298866 12 UNUSED 10306036 10288946 13 UNUSED 10308587 10292691 14 UNUSED 10311371 10288924 15 UNUSED 10310818 10284237 16 UNUSED 10307503 10297027 COMM 1 ELEC DISP INT. 100670 100707 COMM 2 RS232 SERIAL BD 14901 14934 COMM 3 SERIAL SAT BD 484996 485228 COMM 4 UNUSED 10316238 10295275 COMM 5 UNUSED 10299002 10297530 COMM 6 UNUSED 10303019 10281960 I90200 NOV 24, 2020 2:07 PM SOFTWARE REVISION LEVEL VERSION 333.06 SOFTWARE# 346333-100-G CREATED - 14.10.01.16.35 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD/APM I11100 NOV 24, 2020 2:07 PM FLOWER ST MINI MART 928 FLOWER ST BAKERSFIELD CA 93305 661-328-0673 PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME L 8 DISP PAN DISP 5-6 SENSOR OUT ALARM CLEAR 11-24-20 11:03AM L 7 DISP PAN DISP 3-4 SENSOR OUT ALARM CLEAR 11-24-20 11:03AM L 6 DISP PAN DISP 1-2 SENSOR OUT ALARM CLEAR 11-24-20 11:03AM L 4 STP SUMP 91 STP SENSOR OUT ALARM CLEAR 11-24-20 11:03AM L 5 PIPE 91 FILL SENSOR OUT ALARM CLEAR 11-24-20 11:03AM L 3 PIPE 87 FILL SENSOR OUT ALARM CLEAR 11-24-20 11:03AM L 2 STP SUMP 87 STP SENSOR OUT ALARM CLEAR 11-24-20 11:03AM L 1 ANNULAR 87-91 ANNULAR SENSOR OUT ALARM CLEAR 11-24-20 11:03AM L12 DISP PAN DISP 7-8 SENSOR OUT ALARM CLEAR 11-24-20 11:03AM L11 DISP PAN DISP 11-12 SENSOR OUT ALARM CLEAR 11-24-20 11:03AM L10 DISP PAN DISP 9-10 SENSOR OUT ALARM CLEAR 11-24-20 11:03AM L 4 STP SUMP 91 STP SENSOR OUT ALARM ALARM 11-24-20 11:03AM L 3 PIPE 87 FILL SENSOR OUT ALARM ALARM 11-24-20 11:03AM L 2 STP SUMP 87 STP SENSOR OUT ALARM ALARM 11-24-20 11:03AM L 8 DISP PAN DISP 5-6 SENSOR OUT ALARM ALARM 11-24-20 11:03AM L 1 ANNULAR 87-91 ANNULAR SENSOR OUT ALARM ALARM 11-24-20 11:03AM L 7 DISP PAN DISP 3-4 SENSOR OUT ALARM ALARM 11-24-20 11:03AM L12 DISP PAN DISP 7-8 SENSOR OUT ALARM ALARM 11-24-20 11:03AM L 6 DISP PAN DISP 1-2 SENSOR OUT ALARM ALARM 11-24-20 11:03AM L11 DISP PAN DISP 11-12 SENSOR OUT ALARM ALARM 11-24-20 11:03AM L 5 PIPE 91 FILL SENSOR OUT ALARM ALARM 11-24-20 11:02AM L10 DISP PAN DISP 9-10 SENSOR OUT ALARM ALARM 11-24-20 11:02AM L11 DISP PAN DISP 11-12 FUEL ALARM CLEAR 11-24-20 10:59AM L11 DISP PAN DISP 11-12 FUEL ALARM ALARM 11-24-20 10:59AM L10 DISP PAN DISP 9-10 FUEL ALARM CLEAR 11-24-20 10:59AM L10 DISP PAN DISP 9-10 FUEL ALARM ALARM 11-24-20 10:59AM L12 DISP PAN DISP 7-8 FUEL ALARM CLEAR 11-24-20 10:58AM L12 DISP PAN DISP 7-8 FUEL ALARM ALARM 11-24-20 10:58AM L 7 DISP PAN DISP 3-4 FUEL ALARM CLEAR 11-24-20 10:57AM L 7 DISP PAN DISP 3-4 FUEL ALARM ALARM 11-24-20 10:57AM L 8 DISP PAN DISP 5-6 FUEL ALARM CLEAR 11-24-20 10:57AM L 8 DISP PAN DISP 5-6 FUEL ALARM ALARM 11-24-20 10:56AM L 6 DISP PAN DISP 1-2 FUEL ALARM CLEAR 11-24-20 10:56AM L 6 DISP PAN DISP 1-2 FUEL ALARM ALARM 11-24-20 10:56AM L 3 PIPE 87 FILL FUEL ALARM CLEAR 11-24-20 10:54AM L 3 PIPE 87 FILL FUEL ALARM ALARM 11-24-20 10:54AM L 1 ANNULAR 87-91 ANNULAR FUEL ALARM CLEAR 11-24-20 10:53AM L 1 ANNULAR 87-91 ANNULAR FUEL ALARM ALARM 11-24-20 10:53AM L 5 PIPE 91 FILL FUEL ALARM CLEAR 11-24-20 10:53AM L 5 PIPE 91 FILL FUEL ALARM ALARM 11-24-20 10:52AM L 2 STP SUMP 87 STP FUEL ALARM CLEAR 11-24-20 10:52AM L 2 STP SUMP 87 STP FUEL ALARM ALARM 11-24-20 10:51AM L 4 STP SUMP 91 STP FUEL ALARM CLEAR 11-24-20 10:51AM L 4 STP SUMP 91 STP FUEL ALARM ALARM 11-24-20 10:50AM E 1 OTHER G COMMUNICATION ALARM CLEAR 11-22-20 3:42AM E 1 OTHER G COMMUNICATION ALARM ALARM 11-22-20 3:40AM OTHER ISD GROSS PRES FAIL CLEAR 11-19-20 1:27PM OTHER ISD GROSS PRES FAIL ALARM 11-19-20 1:17PM E 1 OTHER G COMMUNICATION ALARM CLEAR 11-15-20 3:43AM E 1 OTHER G COMMUNICATION ALARM ALARM 11-15-20 3:40AM I11200 NOV 24, 2020 2:08 PM FLOWER ST MINI MART 928 FLOWER ST BAKERSFIELD CA 93305 661-328-0673 NON-PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME h 4 OTHER FP4: BLEND3 DEGRD COLLECT WARN CLEAR 11-24-20 1:15PM SYSTEM PRINTER ERROR CLEAR 11-24-20 9:04AM SYSTEM PAPER OUT CLEAR 11-24-20 9:04AM SYSTEM PRINTER ERROR ALARM 11-24-20 9:03AM SYSTEM PAPER OUT ALARM 11-24-20 9:03AM h 4 OTHER FP4: BLEND3 DEGRD COLLECT WARN ALARM 11-23-20 1:16PM h 8 OTHER FP8: BLEND3 DEGRD COLLECT WARN CLEAR 11-20-20 1:15PM h 8 OTHER FP8: BLEND3 DEGRD COLLECT WARN ALARM 11-19-20 1:17PM OTHER ISD GROSS PRES WARN CLEAR 11-19-20 1:15PM h 8 OTHER FP8: BLEND3 DEGRD COLLECT WARN CLEAR 11-17-20 1:15PM T 1 TANK REGULAR UNL DELIVERY NEEDED CLEAR 11-16-20 6:51AM T 1 TANK REGULAR UNL INVALID FUEL LEVEL CLEAR 11-16-20 6:50AM T 1 TANK REGULAR UNL INVALID FUEL LEVEL ALARM 11-16-20 6:39AM T 1 TANK REGULAR UNL DELIVERY NEEDED ALARM 11-15-20 10:01PM h 8 OTHER FP8: BLEND3 DEGRD COLLECT WARN ALARM 11-15-20 1:16PM h 6 OTHER FP6: BLEND3 DEGRD COLLECT WARN CLEAR 11-14-20 1:15PM h12 OTHER FP12: BLEND3 DEGRD COLLECT WARN CLEAR 11-13-20 1:15PM T 1 TANK REGULAR UNL DELIVERY NEEDED CLEAR 11-13-20 4:54AM T 1 TANK REGULAR UNL DELIVERY NEEDED ALARM 11-12-20 7:33PM OTHER ISD GROSS PRES WARN ALARM 11-12-20 1:16PM h 6 OTHER FP6: BLEND3 DEGRD COLLECT WARN ALARM 11-12-20 1:16PM h12 OTHER FP12: BLEND3 DEGRD COLLECT WARN ALARM 11-11-20 1:16PM h 5 OTHER FP5: BLEND3 DEGRD COLLECT WARN CLEAR 11-11-20 1:15PM h 6 OTHER FP6: BLEND3 DEGRD COLLECT WARN CLEAR 11-10-20 1:15PM h 6 OTHER FP6: BLEND3 DEGRD COLLECT WARN ALARM 11-09-20 1:16PM h 5 OTHER FP5: BLEND3 DEGRD COLLECT WARN ALARM 11-09-20 1:16PM OTHER ISD GROSS PRES WARN CLEAR 11-06-20 8:59AM OTHER ISD GROSS PRES WARN ALARM 11-05-20 1:16PM h12 OTHER FP12: BLEND3 DEGRD COLLECT WARN CLEAR 11-05-20 1:15PM h12 OTHER FP12: BLEND3 DEGRD COLLECT WARN ALARM 10-31-20 1:16PM T 2 TANK SUPER UNL DELIVERY NEEDED CLEAR 10-29-20 4:17AM SYSTEM PRINTER ERROR CLEAR 10-28-20 9:09PM SYSTEM PAPER OUT CLEAR 10-28-20 9:09PM T 2 TANK SUPER UNL DELIVERY NEEDED ALARM 10-28-20 6:42PM SYSTEM PRINTER ERROR ALARM 10-27-20 2:00AM SYSTEM PAPER OUT ALARM 10-27-20 2:00AM h 5 OTHER FP5: BLEND3 DEGRD COLLECT WARN CLEAR 10-25-20 1:15PM h 5 OTHER FP5: BLEND3 DEGRD COLLECT WARN ALARM 10-24-20 1:16PM T 1 TANK REGULAR UNL DELIVERY NEEDED CLEAR 10-24-20 6:30AM T 1 TANK REGULAR UNL INVALID FUEL LEVEL CLEAR 10-24-20 6:29AM T 1 TANK REGULAR UNL INVALID FUEL LEVEL ALARM 10-24-20 5:52AM T 1 TANK REGULAR UNL DELIVERY NEEDED ALARM 10-23-20 7:52PM h 6 OTHER FP6: BLEND3 DEGRD COLLECT WARN CLEAR 10-18-20 1:15PM h 6 OTHER FP6: BLEND3 DEGRD COLLECT WARN ALARM 10-17-20 1:16PM T 2 TANK SUPER UNL DELIVERY NEEDED CLEAR 10-13-20 9:33PM T 2 TANK SUPER UNL DELIVERY NEEDED ALARM 10-13-20 7:06PM h 8 OTHER FP8: BLEND3 DEGRD COLLECT WARN CLEAR 9-30-20 12:59PM h 6 OTHER FP6: BLEND3 DEGRD COLLECT WARN CLEAR 9-30-20 12:59PM h 8 OTHER FP8: BLEND3 DEGRD COLLECT WARN ALARM 9-29-20 1:16PM SYSTEM PRINTER ERROR CLEAR 9-28-20 7:29PM I20600 NOV 24, 2020 2:08 PM FLOWER ST MINI MART 928 FLOWER ST BAKERSFIELD CA 93305 661-328-0673 TANK ALARM HISTORY TANK 1 REGULAR UNL HIGH WATER ALARM DEC 3, 2015 9:46 AM OVERFILL ALARM JUN 4, 2020 8:43 PM APR 8, 2020 3:06 PM MAR 22, 2020 8:36 AM LOW PRODUCT ALARM MAR 7, 2020 11:13 AM HIGH PRODUCT ALARM NOV 27, 2019 11:39 AM NOV 13, 2018 11:10 AM NOV 6, 2017 11:29 AM INVALID FUEL LEVEL NOV 16, 2020 6:39 AM OCT 24, 2020 5:52 AM SEP 26, 2020 7:11 AM PROBE OUT NOV 27, 2019 11:39 AM NOV 27, 2019 11:16 AM NOV 13, 2018 11:13 AM HIGH WATER WARNING DEC 3, 2015 9:46 AM DELIVERY NEEDED NOV 15, 2020 10:01 PM NOV 12, 2020 7:33 PM OCT 23, 2020 7:52 PM MAX PRODUCT ALARM NOV 13, 2018 11:10 AM LOW TEMP WARNING NOV 27, 2019 11:40 AM NOV 8, 2016 11:58 AM DEC 3, 2015 10:17 AM TANK 2 SUPER UNL OVERFILL ALARM DEC 3, 2015 10:08 AM LOW PRODUCT ALARM NOV 27, 2019 11:23 AM MAR 3, 2018 12:27 PM FEB 28, 2018 8:47 PM HIGH PRODUCT ALARM NOV 27, 2019 11:21 AM NOV 13, 2018 11:11 AM NOV 6, 2017 11:27 AM INVALID FUEL LEVEL NOV 13, 2018 11:12 AM NOV 6, 2017 11:28 AM NOV 6, 2017 10:16 AM PROBE OUT NOV 27, 2019 11:38 AM NOV 27, 2019 11:21 AM NOV 27, 2019 11:17 AM DELIVERY NEEDED OCT 28, 2020 6:42 PM OCT 13, 2020 7:06 PM AUG 7, 2020 2:29 PM MAX PRODUCT ALARM NOV 13, 2018 11:11 AM LOW TEMP WARNING NOV 27, 2019 11:22 AM DEC 3, 2015 10:11 AM TANK 5 TANK 6 TANK 7 TANK 8 TANK 9 TANK 10 TANK 11 TANK 12 TANK 13 TANK 14 TANK 15 TANK 16 I38200 NOV 24, 2020 2:09 PM I30200 NOV 24, 2020 2:09 PM FLOWER ST MINI MART 928 FLOWER ST BAKERSFIELD CA 93305 661-328-0673 LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 87-91 ANNULAR NOV 24, 2020 11:03 AM SENSOR OUT ALARM NOV 24, 2020 10:53 AM FUEL ALARM NOV 27, 2019 11:59 AM SENSOR OUT ALARM 2 87 STP NOV 24, 2020 11:03 AM SENSOR OUT ALARM NOV 24, 2020 10:51 AM FUEL ALARM NOV 27, 2019 11:59 AM SENSOR OUT ALARM 3 87 FILL NOV 24, 2020 11:03 AM SENSOR OUT ALARM NOV 24, 2020 10:54 AM FUEL ALARM MAR 16, 2020 9:28 PM FUEL ALARM 4 91 STP NOV 24, 2020 11:03 AM SENSOR OUT ALARM NOV 24, 2020 10:50 AM FUEL ALARM NOV 27, 2019 11:59 AM SENSOR OUT ALARM 5 91 FILL NOV 24, 2020 11:02 AM SENSOR OUT ALARM NOV 24, 2020 10:52 AM FUEL ALARM MAY 10, 2020 4:44 AM FUEL ALARM 6 DISP 1-2 NOV 24, 2020 11:03 AM SENSOR OUT ALARM NOV 24, 2020 10:56 AM FUEL ALARM NOV 27, 2019 11:59 AM SENSOR OUT ALARM 7 DISP 3-4 NOV 24, 2020 11:03 AM SENSOR OUT ALARM NOV 24, 2020 10:57 AM FUEL ALARM NOV 27, 2019 11:59 AM SENSOR OUT ALARM 8 DISP 5-6 NOV 24, 2020 11:03 AM SENSOR OUT ALARM NOV 24, 2020 10:56 AM FUEL ALARM NOV 27, 2019 11:59 AM SENSOR OUT ALARM 10 DISP 9-10 NOV 24, 2020 11:02 AM SENSOR OUT ALARM NOV 24, 2020 10:59 AM FUEL ALARM NOV 27, 2019 11:59 AM SENSOR OUT ALARM 11 DISP 11-12 NOV 24, 2020 11:03 AM SENSOR OUT ALARM NOV 24, 2020 10:59 AM FUEL ALARM NOV 27, 2019 11:59 AM SENSOR OUT ALARM 12 DISP 7-8 NOV 24, 2020 11:03 AM SENSOR OUT ALARM NOV 24, 2020 10:58 AM FUEL ALARM NOV 27, 2019 11:59 AM SENSOR OUT ALARM I31600 NOV 24, 2020 2:09 PM FLOWER ST MINI MART 928 FLOWER ST BAKERSFIELD CA 93305 661-328-0673 SMART SENSOR ALARM HISTORY REPORT SENSOR LOCATION 1 VAPOR PRESSUR 2 FM 1-2 3 FM 3-4 4 FM 5-6 5 FM 7-8 6 FM 9-10 7 FM 11-12 I40200 NOV 24, 2020 2:09 PM I40300 NOV 24, 2020 2:09 PM I34200 NOV 24, 2020 2:09 PM I34700 NOV 24, 2020 2:09 PM IV0100 NOV 24, 2020 2:09 PM FLOWER ST MINI MART 928 FLOWER ST BAKERSFIELD CA 93305 661-328-0673 ISD ALARM STATUS REPORT EVR TYPE: VACUUM ASSIST ISD TYPE: 01.05 VAPOR PROCESSOR TYPE: NONE OVERALL STATUS :PASS EVR VAPOR COLLECTION :PASS EVR VAPOR CONTAINMENT :PASS ISD MONITOR UP-TIME : 99% EVR/ISD PASS TIME :100% WARNING ALARMS DATE TIME DESCRIPTION READING VALUE 20-11-23 13:16:51 A/L RATIO DEGRADATION FP 4 BLEND3 0.81 20-11-19 13:17:04 A/L RATIO DEGRADATION FP 8 BLEND3 0.80 20-11-18 13:16:58 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.49 20-11-17 13:16:51 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.46 20-11-16 13:17:02 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.62 20-11-16 13:17:02 A/L RATIO DEGRADATION FP 8 BLEND3 0.80 20-11-15 13:16:48 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.71 20-11-15 13:16:48 A/L RATIO DEGRADATION FP 8 BLEND3 0.80 20-11-14 13:16:19 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.79 20-11-13 13:16:09 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.79 FAILURE ALARMS DATE TIME DESCRIPTION READING VALUE 20-11-19 13:17:04 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.49 20-09-07 13:17:57 A/L RATIO DEGRADATION FP 6 BLEND3 0.77 20-02-10 06:02:10 A/L RATIO GROSS BLOCKAGE FP 8 BLEND3 BLKD 20-02-10 06:02:09 A/L RATIO GROSS BLOCKAGE FP 7 BLEND3 BLKD 20-02-01 06:03:01 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 2.14 19-12-13 06:02:51 A/L RATIO DEGRADATION FP12 BLEND3 0.72 19-12-12 06:02:24 A/L RATIO DEGRADATION FP12 BLEND3 0.73 19-12-11 06:02:21 A/L RATIO DEGRADATION FP12 BLEND3 0.69 19-11-27 06:02:33 A/L RATIO DEGRADATION FP 8 BLEND3 0.72 19-11-26 06:02:22 A/L RATIO DEGRADATION FP 8 BLEND3 0.71 SHUTDOWN & MISCELLANEOUS EVENTS DATE TIME DESCRIPTION ACTION/NAME 20-11-24 13:17:16 READINESS ISD:PP EVR:PP ISD & EVR READY 20-11-24 11:03:52 READINESS ISD:PP EVR:NN EVR READINESS PENDING 20-11-24 11:03:52 ISD STARTUP 20-11-24 11:03:45 ISD SHUTDOWN 20-11-19 13:27:18 CONTAINMENT GROSS & DEGRD TEST MANUALLY CLEARED 20-11-19 13:25:01 PUMPS MANUALLY RE-ENABLED 20-11-19 13:17:04 CONTAINMENT GROSS DISABLED DISPENSERS 20-11-06 08:59:20 CONTAINMENT GROSS & DEGRD TEST MANUALLY CLEARED 20-09-30 12:59:52 COLLECTION TEST HH08 GRADE TEST MANUALLY CLEARED 20-09-30 12:59:48 COLLECTION TEST HH06 GRADE TEST MANUALLY CLEARED Appendix VIII Underground Storage Tank Spill Container Testing Report Form CERS = California Environmental Reporting System, ID = Identification, ICC = International Code Council Page 1 of 2 TYPE OF ACTION ܆܆ Installation ܆ Repair ܆ 12 Month 1. FACILITY INFORMATION CERS ID Test Date Facility Name Facility Address City ZIP Code 2. SERVICE TECHNICIAN INFORMATION Company Performing the Test Phone Mailing Address Service Technician Performing Test Contractor/Tank Tester License Number ICC Number ICC Expiration Date 3. TRAINING AND CERTIFICATIONS Manufacturer and Test Equipment Training Certifications Expiration Date 4. TEST PROCEDURE INFORMATION Test Procedures Used Components Tested 5. CERTIFICATION BY SERVICE TECHNICIAN CONDUCTING TEST I hereby certify that each spill container was tested in accordance with California Code of Regulations, title 23, division 3, chapter 16, section 2637.1; that required supporting documentation is attached; and all information contained herein is accurate. I understand that test procedures shall be made available upon request by the governing authority. Service Technician Signature Date Total # of Pages 10125616 11/24/2020 Express Gas 928 Flower Street Bakersfield 93305 Confidence UST Services, Inc.(800) 339-9930 16250 Meacham Road, Bakersfield, CA 93314 Jason Woods 804904 8492093 5/6/2021 Veeder-Root C26937 8/8/2021 PHILTITE 1015883711 6/26/2021 PEI 1200 87,91 spill buckets 11/24/2020 Underground Storage Tank Spill Container Testing Report Form Additional copies of this page may be attached. Page 2 of 2 6. SPILL CONTAINER DETAILS Test Method Developed by ܆܆ Manufacturer ܆܆ Industry Standard ܆܆ Professional Engineer Test Type ܆܆ Pressure ܆܆ Vacuum ܆܆ Hydrostatic Tank ID Spill Container Manufacturer: Method of Cathodic Protection ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other Is the spill container minimum capacity five gallons excluding riser volume? ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* Method to keep spill container empty ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other Spill Container Test Results ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail Tank ID Spill Container Manufacturer: Method of Cathodic Protection ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other Is the spill container minimum capacity five gallons excluding riser volume? ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* Method to keep spill container empty ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other Spill Container Test Results ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail 1 8. COMMENTS Describe all answers marked “Other,” “No,” or “Fail” and each proposed remedy. * Mark here if: Spill containers do not have a minimum capacity of five gallons and require replacement. T1 Unleaded PHILTITE T2 PNL PHILTITE Underground Storage Tank Monitoring System Certification Form Page 6 of 6 10. MONITORING SITE PLAN Date site plan was prepared: If a site plan has been prepared that shows all required information, you may include it, rather than this page, with your Monitoring System Certification Form. The site plan must show the general layout of tanks and identify locations of the monitoring panel, and all leak detection equipment and monitoring locations. Include a legend for all symbols depicted.