Loading...
HomeMy WebLinkAbout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ame as Facility Name or DBA-Doing Business As) %XVLQHVV6LWH$GGUHVV &LW\ =,3&RGH ,, 81'(5*5281'6725$*(7$1.6(59,&(7(&+1,&,$1,1)250$7,21 1DPHRI&RPSDQ\3HUIRUPLQJWKH&HUWLILFDWLRQ 3KRQH 0DLOLQJ$GGUHVV 1DPHRI8676HUYLFH7HFKQLFLDQ3HUIRUPLQJWKH&HUWLILFDWLRQ(Print as shown on the ICC Certification) &RQWUDFWRU7DQN7HVWHU/LFHQVH ,&&&HUWLILFDWLRQ ,&&&HUWLILFDWLRQ([SLUDWLRQ'DWH 0RQLWRULQJ6\VWHP7UDLQLQJDQG&HUWLILFDWLRQV(List all applicable certifications.) ([SLUDWLRQ'DWH ,,, 5(68/762)7(67,1*6(59,&,1* Indicate and attach the following reports if the monitoring equipment is capable of generating either.<11$0RQLWRULQJ6\VWHP6HWXS$ODUP+LVWRU\5HSRUW :DVDQ\PRQLWRULQJHTXLSPHQWUHSODFHG" (If “Yes,” identify the specific devices replaced and list the manufacturer and model for all replacement parts in section IV below.) :DVGDPDJHGHEULVRUOLTXLGIRXQGLQVLGHDQ\VHFRQGDU\FRQWDLQPHQWV\VWHPV" (If “Yes,” describe what was found in section IV below.) ,VDOOPRQLWRULQJHTXLSPHQWRSHUDWLRQDOSHUPDQXIDFWXUHU¶VVSHFLILFDWLRQV" (If “No,” describe why in section IV below.) ,9 &200(176 If directed to use this section, describe how and when the issues were or will be corrected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aco #7705 Fastrip #641 1200 Coffee Rd Bakersfield 93308 16250 Meacham Road, Bakersfield, CA 93314 Aaron Perrigo 804904 8485827 2/25/2021 Veede-root B47853 8/3/2021 Confidence UST Services, Inc. (800) 339-9930 ,' ,GHQWLILFDWLRQ6: 6LQJOH:DOOHG93+ 9DFXXP3UHVVXUH+\GURVWDWLF//' /LQH/HDN'HWHFWRU 81 ZZZXQLGRFVRUJ 5HY 81'(5*5281'6725$*(7$1. 021,725,1*6<67(0&(57,),&$7,21)250 3DJHRI  9, ,19(1725<2)(48,30(17&(57,),(' A separate Monitoring System Certification Form must be prepared for each monitoring system control panel. 0DNHRI0RQLWRULQJ6\VWHP&RQWURO3DQHO  0RGHORI0RQLWRULQJ6\VWHP&RQWURO3DQHO  6RIWZDUH9HUVLRQ,QVWDOOHG  Check the appropriate boxes to indicate specific equipment inspected/serviced. 0RQLWRULQJ'HYLFH8VHG'HYLFH0RGHO0RQLWRULQJ'HYLFH8VHG'HYLFH0RGHO 7$1.,' (By tank number, stored product, etc.) 7$1.,' (By tank number, stored product, etc.) ,Q7DQN*DXJLQJ(SW Tank),Q7DQN*DXJLQJ(SW Tank) $QQXODU6SDFHRU9DXOW6HQVRU$QQXODU6SDFHRU9DXOW6HQVRU 93+6HQVRU93+6HQVRU 3URGXFW3LSLQJ3URGXFW3LSLQJ 0HFKDQLFDO//'0HFKDQLFDO//' (OHFWURQLF//'(OHFWURQLF//' 93+6HQVRU 3LSLQJ 93+6HQVRU 3LSLQJ  6XPS6HQVRU6XPS6HQVRU 93+6HQVRU 6XPS 93+6HQVRU 6XPS  )LOO3LSLQJ)LOO3LSLQJ 93+6HQVRU 3LSLQJ 93+6HQVRU 3LSLQJ  6XPS6HQVRU6XPS6HQVRU 93+6HQVRU 6XPS 93+6HQVRU 6XPS  9HQW3LSLQJ9HQW3LSLQJ 93+6HQVRU 3LSLQJ 93+6HQVRU 3LSLQJ  6XPS6HQVRU6XPS6HQVRU 93+6HQVRU 6XPS 93+6HQVRU 6XPS  9DSRU5HFRYHU\3LSLQJ9DSRU5HFRYHU\3LSLQJ 93+6HQVRU 3LSLQJ 93+6HQVRU 3LSLQJ  6XPS6HQVRU6XPS6HQVRU 93+6HQVRU 6XPS 93+6HQVRU 6XPS  0RQLWRULQJ'HYLFH8VHG 'HYLFH0RGHO0RQLWRULQJ'HYLFH8VHG 'HYLFH0RGHO 7$1.,' (By tank number, stored product, etc.) 7$1.,' (By tank number, stored product, etc.) ,Q7DQN*DXJLQJ(SW Tank),Q7DQN*DXJLQJ(SW Tank) $QQXODU6SDFHRU9DXOW6HQVRU$QQXODU6SDFHRU9DXOW6HQVRU 93+6HQVRU93+6HQVRU 3URGXFW3LSLQJ3URGXFW3LSLQJ 0HFKDQLFDO//'0HFKDQLFDO//' (OHFWURQLF//'(OHFWURQLF//' 93+6HQVRU 3LSLQJ 93+6HQVRU 3LSLQJ  6XPS6HQVRU6XPS6HQVRU 93+6HQVRU 6XPS 93+6HQVRU 6XPS  )LOO3LSLQJ)LOO3LSLQJ 93+6HQVRU 3LSLQJ 93+6HQVRU 3LSLQJ  6XPS6HQVRU6XPS6HQVRU 93+6HQVRU 6XPS 93+6HQVRU 6XPS  9HQW3LSLQJ9HQW3LSLQJ 93+6HQVRU 3LSLQJ 93+6HQVRU 3LSLQJ  6XPS6HQVRU6XPS6HQVRU 93+6HQVRU 6XPS 93+6HQVRU 6XPS  9DSRU5HFRYHU\3LSLQJ9DSRU5HFRYHU\3LSLQJ 93+6HQVRU 3LSLQJ 93+6HQVRU 3LSLQJ  6XPS6HQVRU6XPS6HQVRU 93+6HQVRU 6XPS 93+6HQVRU 6XPS  Veederoot TLS-350 327.04 T1:87 847390-107 794380-420 FX1V 794380-208 794380-208 T2:91 847390-107 794390-344 FX1V 794380-208 794380-208 T3: Diesel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pecify in section VII.)2WKHU(Specify in section VII.) 2WKHU0RQLWRUHG&RPSRQHQW,'2WKHU0RQLWRUHG&RPSRQHQW,' 2WKHU(Specify in section VII.)2WKHU(Specify in section VII.) 2WKHU0RQLWRUHG&RPSRQHQW,'2WKHU0RQLWRUHG&RPSRQHQW,' 2WKHU(Specify in section VII.)2WKHU(Specify in section VII.) Include information for every underground storage tank component monitored by this monitoring system control panel. If the monitoring system control panel monitors more components than this form accommodates, additional copies of these pages may be attached. 9,, &200(176 Use this section to provide additional comments about the inventory of the equipment certified.  1/2 794380-208 3/4 794380-208 5/6 794380-208 7/8 794380-208 < <HV1 1R1$ 1RW$SSOLFDEOH 81 ZZZXQLGRFVRUJ 5HY 81'(5*5281'6725$*(7$1. 021,725,1*6<67(0&(57,),&$7,21)250 3DJHRI  9,,, 021,725,1*6<67(0$1'352*5$00,1* This section must be completed if a monitoring panel is used to perform leak detection monitoring.<11$ $UHWKHYLVXDODQGDXGLEOHDODUPVRSHUDWLRQDO" :HUHDOOVHQVRUVYLVXDOO\LQVSHFWHGIRUNLQNVDQGEUHDNVLQWKHFDEOHVDQGIRUUHVLGXDOEXLOGXSWRHQVXUHWKDWIORDWVPRYHIUHHO\ IXQFWLRQDOO\WHVWHGDQGFRQILUPHGRSHUDWLRQDO" :HUHDOOVHQVRUVLQVWDOOHGDWORZHVWSRLQWRIVHFRQGDU\FRQWDLQPHQWDQGSRVLWLRQHGVRWKDWRWKHUHTXLSPHQWZLOOQRWLQWHUIHUHZLWK WKHLUSURSHURSHUDWLRQ" :DVPRQLWRULQJV\VWHPVHWXSUHYLHZHGWRHQVXUHSURSHUVHWWLQJV" :DVWKHPRQLWRULQJSDQHO¶VEDFNXSEDWWHU\YLVXDOO\LQVSHFWHGIXQFWLRQDOO\WHVWHGDQGFRQILUPHGRSHUDWLRQDO" 'RHVWKHIORZRIIXHOVWRSDWWKHGLVSHQVHULIDOHDNLVGHWHFWHGLQWKHXQGHUGLVSHQVHUFRQWDLQPHQW" 'RHVWKHWXUELQHDXWRPDWLFDOO\VKXWGRZQLIWKHSLSLQJVHFRQGDU\FRQWDLQPHQWPRQLWRULQJV\VWHPIDLOVWRRSHUDWHRULVHOHFWULFDOO\ GLVFRQQHFWHG" 'RHVWKHWXUELQHDXWRPDWLFDOO\VKXWGRZQLIWKHSLSLQJVHFRQGDU\FRQWDLQPHQWPRQLWRULQJV\VWHPGHWHFWVDOHDN" :KLFKVHQVRUVLQLWLDWHSRVLWLYHVKXWGRZQ"(Check all that apply.)6XPS8QGHU'LVSHQVHU&RQWDLQPHQW ,IDODUPVDUHUHOD\HGWRDUHPRWHPRQLWRULQJVWDWLRQLVDOOFRPPXQLFDWLRQVHTXLSPHQW HJPRGHP RSHUDWLRQDO" For any answer of “N” above, describe in Section IX how and when these deficiencies were or will be corrected. ,; &200(176 ; ,17$1.*$8*,1*7(67,1* &KHFNWKLVER[LIWDQNJDXJLQJLVXVHGRQO\IRULQYHQWRU\FRQWURO(Do not complete this section.) <11$&KHFNWKLVER[LI12WDQNJDXJLQJHTXLSPHQWLVLQVWDOOHG (Do not complete this section.) This section must be completed if in-tank gauging is used to perform leak detection monitoring. +DVDOOLQSXWZLULQJEHHQLQVSHFWHGIRUNLQNVDQGEUHDNVLQWKHFDEOHVDQGIRUSURSHUHQWU\DQGWHUPLQDWLRQLQFOXGLQJWHVWLQJIRU JURXQGIDXOWV" :HUHDOOLQWDQNJDXJLQJSUREHVYLVXDOO\LQVSHFWHGIRUGDPDJHDQGUHVLGXHEXLOGXSWRHQVXUHWKDWIORDWVPRYHIUHHO\IXQFWLRQDOO\ WHVWHGDQGFRQILUPHGRSHUDWLRQDO" :DVDFFXUDF\RIV\VWHP¶VSURGXFWOHYHOUHDGLQJVWHVWHG" :DVDFFXUDF\RIV\VWHP¶VZDWHUOHYHOUHDGLQJVWHVWHG" :HUHDOOSUREHVUHLQVWDOOHGSURSHUO\" :HUHDOOLWHPVRQWKHHTXLSPHQWPDQXIDFWXUHU¶VPDLQWHQDQFHFKHFNOLVWFRPSOHWHG" For any answer of “N” above, describe in Section XI how and when these deficiencies were or will be corrected. ;, &200(176 *3+ *DOORQV3HU+RXU< <HV1 1R1$ 1RW$SSOLFDEOH93+ 9DFXXP3UHVVXUH+\GURVWDWLF,' ,GHQWLILFDWLRQ 81 ZZZXQLGRFVRUJ5HY 81'(5*5281'6725$*(7$1. 021,725,1*6<67(0&(57,),&$7,21)250 3DJHRI  ;,, /,1(/($.'(7(&7257(67,1* &KHFNWKLVER[LIOLQHOHDNGHWHFWRUV //' DUH127LQVWDOOHG(Do not complete this section.)<11$This section must be completed if LLDs are installed. :DVDOHDNVLPXODWHGWRYHULI\//'SHUIRUPDQFH" (Check all that apply.)6LPXODWHGOHDNUDWHYHULILHG*3+*3+*3+ :DVWKHWHVWLQJDSSDUDWXVSURSHUO\FDOLEUDWHG" )RUHPHUJHQF\JHQHUDWRUWDQNV\VWHPVGRHVWKH//'FUHDWHDQDXGLEOHDQGYLVXDODODUPZKHQDOHDNLVGHWHFWHG" )RUPHFKDQLFDO//'VGRHVWKH//'UHVWULFWWKHIORZWKURXJKWKHSLSHZKHQDOHDNLVGHWHFWHG" )RUHOHFWURQLF//'VGRHVWKHWXUELQHDXWRPDWLFDOO\VKXWRIIZKHQDOHDNLVGHWHFWHG" )RUHOHFWURQLF//'VGRHVWKHWXUELQHDXWRPDWLFDOO\VKXWRIILIDQ\SRUWLRQRIWKHPRQLWRULQJV\VWHPLVGLVDEOHGRUGLVFRQQHFWHG" )RUHOHFWURQLF//'VGRHVWKHWXUELQHDXWRPDWLFDOO\VKXWRIILIDQ\SRUWLRQRIWKHPRQLWRULQJV\VWHPPDOIXQFWLRQVRUIDLOVDWHVW" )RUHOHFWURQLF//'VKDYHDOODFFHVVLEOHZLULQJFRQQHFWLRQVEHHQYLVXDOO\LQVSHFWHGIRUNLQNVDQGEUHDNV" :HUHDOOLWHPVRQWKHHTXLSPHQWPDQXIDFWXUHU¶VPDLQWHQDQFHFKHFNOLVWFRPSOHWHG" :HUHDOO//'VFRQILUPHGRSHUDWLRQDOZLWKLQUHJXODWRU\UHTXLUHPHQWV" For any answer of “N” above, describe in Section XIII how and when these issues were or will be corrected. ;,,, &200(176 ;,9 9$&88035(6685(+<'5267$7,&021,725,1*(48,30(177(67,1* &KHFNWKLVER[LI93+PRQLWRULQJLV127XVHG(Do not complete this section.) This section must be completed if VPH monitoring is used to perform leak detection monitoring. 6\VWHP7\SH 0DUNDOOWKDWDSSO\ 9DFXXP3UHVVXUH+\GURVWDWLF 6HQVRU,'&RPSRQHQW 6 0RQLWRUHG%\7KLV6HQVRU 6HQVRU)XQFWLRQDOLW\ 7HVW ,QWHUVWLWLDO&RPPXQLFDWLRQ 7HVW 3DVV )DLO 3DVV )DLO 3DVV)DLO3DVV)DLO 3DVV)DLO3DVV)DLO 3DVV)DLO3DVV)DLO 3DVV)DLO3DVV)DLO 3DVV)DLO3DVV)DLO 3DVV)DLO3DVV)DLO 3DVV)DLO3DVV)DLO 3DVV)DLO3DVV)DLO 3DVV)DLO3DVV)DLO 3DVV)DLO3DVV)DLO 3DVV)DLO3DVV)DLO +RZZDVLQWHUVWLWLDOFRPPXQLFDWLRQYHULILHG"6LPXODWHG/HDNDW)DU(QGVRIWKH,QWHUVWLWLDO6SDFH9LVXDO,QVSHFWLRQ 2WKHU(Describe the method in section XV below.)*DXJH :DVWKHYDFXXPRUSUHVVXUHUHVWRUHGWRRSHUDWLQJOHYHOVLQDOOLQWHUVWLWLDOVSDFHV"<HV1R(Describe the reason in section XV below.) For any answer of “Fail” above, describe in Section XV how and when these issues were or will be corrected. ;9 &200(176 Jaco 7705 Setup Responses Received: 200 FASTRIP 705 1200 COFFEE RD. BAKERSFIELD CB 93308 661-589-6305 JUL 21, 2020 9:16 AM TANK PRODUCT GALLONS INCHES WATER DEG F ULLAGE 1 UNLEADED 7365 65.32 1.0 88.1 4667 2 PREMIUM 6794 61.15 0.0 86.5 5238 3 DIESEL 4721 46.07 0.8 88.2 7311 I90500 JUL 21, 2020 9:16 AM SOFTWARE REVISION LEVEL VERSION 327.04 SOFTWARE# 346327-100-E CREATED - 07.02.06.10.28 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD PMC I50500 JUL 21, 2020 9:17 AM SYSTEM TYPE AND LANGUAGE FLAG SYSTEM UNITS U.S. SYSTEM LANGUAGE ENGLISH SYSTEM DATE/TIME FORMAT MON DD YYYY HH:MM:SS xM I50201 JUL 21, 2020 9:17 AM SHIFT TIME 1 : 11:00 PM I50202 JUL 21, 2020 9:17 AM SHIFT TIME 2 : DISABLED I50203 JUL 21, 2020 9:17 AM SHIFT TIME 3 : DISABLED I50204 JUL 21, 2020 9:17 AM SHIFT TIME 4 : DISABLED I54600 JUL 21, 2020 9:17 AM TANK PER TST NEEDED WRN: DISABLED I54900 JUL 21, 2020 9:17 AM TANK ANN TST NEEDED WRN: DISABLED I55300 JUL 21, 2020 9:17 AM LINE RE-ENABLE METHOD PASS LINE TEST I55600 JUL 21, 2020 9:17 AM LINE PER TST NEEDED WRN: DISABLED I55900 JUL 21, 2020 9:17 AM LINE ANN TST NEEDED WRN: DISABLED I50D00 JUL 21, 2020 9:17 AM PRINT TC VOLUMES ENABLED I50E00 JUL 21, 2020 9:17 AM TEMP COMPENSATION VALUE (DEG F ): 60.0 I60B00 JUL 21, 2020 9:17 AM STICK HEIGHT OFFSET ENABLE STATUS DISABLED I51400 JUL 21, 2020 9:17 AM H-PROTOCOL DATA FORMAT HEIGHT I51A01 JUL 21, 2020 9:17 AM DAYLIGHT SAVING TIME ENABLED ON I51B00 JUL 21, 2020 9:17 AM DAYLIGHT SAVING TIME START DATE MAR WEEK 2 SUN 2:00 AM END DATE OCT WEEK 6 SUN 2:00 AM I51600 JUL 21, 2020 9:17 AM RE-DIRECT LOCAL PRINTOUT DISABLED I50400 JUL 21, 2020 9:17 AM 232 SECURITY CODE PORT SECURITY CODE STATUS 1 000000 DISABLED 2 000000 DISABLED 3 000000 DISABLED 4 000000 DISABLED 5 000000 DISABLED 6 000000 DISABLED I21900 JUL 21, 2020 9:17 AM TANK CHART SECURITY DISABLED I5BD00 JUL 21, 2020 9:17 AM CUSTOM ALARM LABELS DISABLED I56000 JUL 21, 2020 9:17 AM MASS/DENSITY DISABLED I88101 JUL 21, 2020 9:17 AM PORT SETTINGS: COMM BOARD : 1 (RS-232) BAUD RATE : 9600 PARITY : NONE STOP BIT : 1 STOP DATA LENGTH: 8 DATA RS-232 SECURITY CODE : DISABLED I88102 JUL 21, 2020 9:17 AM PORT SETTINGS: COMM BOARD : 2 (EDIM ) RS-232 SECURITY CODE : DISABLED I88103 JUL 21, 2020 9:17 AM PORT SETTINGS: COMM BOARD : 3 (RS-232) BAUD RATE : 9600 PARITY : NONE STOP BIT : 1 STOP DATA LENGTH: 8 DATA RS-232 SECURITY CODE : DISABLED I88104 JUL 21, 2020 9:17 AM I88105 JUL 21, 2020 9:17 AM I88106 JUL 21, 2020 9:17 AM I52000 JUL 21, 2020 9:17 AM RECEIVER AUTO DIAL TYPE & START TIME RCVR LOCATION LABEL DIAL TYPE START TIME 1 ON DATE DEC 7, 2010 DISABLED 2 ON DATE DEC 7, 2010 DISABLED 3 ON DATE DEC 7, 2010 DISABLED 4 ON DATE DEC 7, 2010 DISABLED 5 ON DATE DEC 7, 2010 DISABLED 6 ON DATE DEC 7, 2010 DISABLED 7 ON DATE DEC 7, 2010 DISABLED 8 ON DATE DEC 7, 2010 DISABLED I60100 JUL 21, 2020 9:17 AM TANK CONFIGURATION DEVICE LABEL CONFIGURED 1 UNLEADED ON 2 PREMIUM ON 3 DIESEL ON 4 OFF I60200 JUL 21, 2020 9:17 AM TANK PRODUCT LABEL TANK PRODUCT LABEL 1 UNLEADED 2 PREMIUM 3 DIESEL 4 I60300 JUL 21, 2020 9:17 AM TANK PRODUCT CODE TANK PRODUCT LABEL 1 UNLEADED 1 2 PREMIUM 2 3 DIESEL 3 4 4 I60900 JUL 21, 2020 9:17 AM TANK THERMAL COEFFICIENT TANK PRODUCT LABEL 1 UNLEADED 0.000700 2 PREMIUM 0.000700 3 DIESEL 0.000450 4 0.000000 I60700 JUL 21, 2020 9:17 AM TANK DIAMETER TANK PRODUCT LABEL INCHES 1 UNLEADED 111.00 2 PREMIUM 111.00 3 DIESEL 111.00 4 0.00 I60A00 JUL 21, 2020 9:17 AM TANK FULL VOLUME TANK PRODUCT LABEL TANK PROFILE GALLONS 1 UNLEADED 1 PT 12032 2 PREMIUM 1 PT 12032 3 DIESEL 1 PT 12032 4 1 PT 0 I60400 JUL 21, 2020 9:17 AM TANK FULL VOLUME TANK PRODUCT LABEL GALLONS 1 UNLEADED 12032 2 PREMIUM 12032 3 DIESEL 12032 4 0 I60500 JUL 21, 2020 9:17 AM TANK 4 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 UNLEADED 12032 0 0 0 2 PREMIUM 12032 0 0 0 3 DIESEL 12032 0 0 0 4 0 0 0 0 I60600 JUL 21, 2020 9:17 AM TANK 20 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 UNLEADED 12032 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 PREMIUM 12032 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3 DIESEL 12032 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 I61500 JUL 21, 2020 9:17 AM TANK PRODUCT LABEL METER DATA 1 UNLEADED NO 2 PREMIUM NO 3 DIESEL NO 4 NO I62F00 JUL 21, 2020 9:17 AM MAG PROBE FLOAT SIZE TANK PRODUCT LABEL FLOAT SIZE: 1 UNLEADED 4.0 INCHES 2 PREMIUM 4.0 INCHES 3 DIESEL 4.0 INCHES I62700 JUL 21, 2020 9:17 AM TANK HIGH WATER WARNING LIMIT TANK PRODUCT LABEL INCHES 1 UNLEADED 2.0 2 PREMIUM 2.0 3 DIESEL 2.0 9999FF1B I62400 JUL 21, 2020 9:17 AM TANK HIGH WATER LEVEL LIMIT TANK PRODUCT LABEL INCHES 1 UNLEADED 3.0 2 PREMIUM 3.0 3 DIESEL 3.0 I62800 JUL 21, 2020 9:17 AM TANK MAXIMUM VOLUME LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 12032 2 PREMIUM 12032 3 DIESEL 12032 4 0 I62300 JUL 21, 2020 9:17 AM TANK OVERFILL LEVEL LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 10828 2 PREMIUM 10828 3 DIESEL 10828 4 0 I62200 JUL 21, 2020 9:17 AM TANK HIGH PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 11430 2 PREMIUM 11430 3 DIESEL 11430 4 0 I62900 JUL 21, 2020 9:17 AM TANK DELIVERY REQUIRED LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 1804 2 PREMIUM 1804 3 DIESEL 1804 4 0 I62100 JUL 21, 2020 9:17 AM TANK LOW PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 500 2 PREMIUM 500 3 DIESEL 500 4 0 I62600 JUL 21, 2020 9:17 AM TANK LEAK ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 99 2 PREMIUM 99 3 DIESEL 99 4 99 I62500 JUL 21, 2020 9:17 AM TANK SUDDEN LOSS LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 99 2 PREMIUM 99 3 DIESEL 99 4 99 I60800 JUL 21, 2020 9:17 AM TANK TILT TANK PRODUCT LABEL INCHES 1 UNLEADED 5.40 2 PREMIUM 5.00 3 DIESEL 1.00 4 0.00 I60B00 JUL 21, 2020 9:17 AM STICK HEIGHT OFFSET ENABLE STATUS DISABLED I60C00 JUL 21, 2020 9:17 AM TANK STICK HEIGHT OFFSET TANK PRODUCT LABEL INCHES 1 UNLEADED 0.00 2 PREMIUM 0.00 3 DIESEL 0.00 4 0.00 I61200 JUL 21, 2020 9:17 AM TANK MANIFOLDED PARTNERS TANK PRODUCT LABEL SIPHON MANIFOLDED TANKS LINE MANIFOLDED TANKS 1 UNLEADED NONE NONE 2 PREMIUM NONE NONE 3 DIESEL NONE NONE 4 NONE NONE I63600 JUL 21, 2020 9:17 AM PERIODIC LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 UNLEADED 120 2 PREMIUM 120 3 DIESEL 120 4 0 I62A00 JUL 21, 2020 9:17 AM ANNUAL LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 UNLEADED 120 2 PREMIUM 120 3 DIESEL 120 4 0 I62C00 JUL 21, 2020 9:17 AM TANK PERIODIC TEST TYPE TANK PRODUCT LABEL PERIODIC TEST TYPE 1 UNLEADED STANDARD 2 PREMIUM STANDARD 3 DIESEL STANDARD 4 STANDARD I62D00 JUL 21, 2020 9:17 AM TANK LEAK TEST FAIL ALARMS TANK PRODUCT LABEL 1 UNLEADED GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 2 PREMIUM GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 3 DIESEL GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 4 GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED I63100 JUL 21, 2020 9:17 AM TANK LEAK TEST AVERAGING TANK PRODUCT LABEL ANNUAL PERIODIC 1 UNLEADED OFF OFF 2 PREMIUM OFF OFF 3 DIESEL OFF OFF 4 OFF OFF I63000 JUL 21, 2020 9:17 AM IN-TANK LEAK TEST NOTIFY TANK PRODUCT LABEL TANK TEST NOTIFY: 1 UNLEADED OFF 2 PREMIUM OFF 3 DIESEL OFF 4 OFF I63200 JUL 21, 2020 9:17 AM TANK TEST SIPHON BREAK TANK PRODUCT LABEL SIPHON BREAK 1 UNLEADED OFF 2 PREMIUM OFF 3 DIESEL OFF 4 OFF I61000 JUL 21, 2020 9:17 AM TANK DELIVERY DELAY TANK PRODUCT LABEL 1 UNLEADED 1 2 PREMIUM 1 3 DIESEL 1 4 1 I63A00 JUL 21, 2020 9:17 AM LOW LEVEL PUMP THRESHOLD FOR SEQUENTIAL LINE MANIFOLD TANK PRODUCT LABEL PUMP THRESHOLD 1 UNLEADED 10.00% 2 PREMIUM 10.00% 3 DIESEL 10.00% 4 10.00% I61100 JUL 21, 2020 9:17 AM LEAK TEST METHOD - - - - - - - - - - - - TEST ON DATE : ALL TANK JAN 15, 2008 START TIME : 2:00 AM TEST RATE :0.20 GAL/HR DURATION : 2 HOURS TST EARLY STOP:DISABLED I61300 JUL 21, 2020 9:17 AM CSLD PROBABLITY OF DETECTION I61400 JUL 21, 2020 9:17 AM CSLD CLIMATE FACTOR I61600 JUL 21, 2020 9:17 AM TANK PRODUCT LABEL CAL UPDATE 1 UNLEADED IMMEDIATE 2 PREMIUM IMMEDIATE 3 DIESEL IMMEDIATE 4 IMMEDIATE I61A00 JUL 21, 2020 9:17 AM IN-TANK LEAK TEST EARLY STOP TANK PRODUCT LABEL TST EARLY STOP: 1 UNLEADED DISABLED 2 PREMIUM DISABLED 3 DIESEL DISABLED 4 DISABLED I61B00 JUL 21, 2020 9:17 AM IN-TANK LEAK GROSS TEST AUTO-CONFIRM I61C00 JUL 21, 2020 9:17 AM CSLD REPORT ONLY I62B00 JUL 21, 2020 9:17 AM TANK LAST ANNUAL TEST TANK PRODUCT LABEL DATE 1 UNLEADED ??? 0, 0 2 PREMIUM ??? 0, 0 3 DIESEL ??? 0, 0 4 ??? 0, 0 I63300 JUL 21, 2020 9:17 AM LEAK TEST REPORT FORMAT: NORMAL I63400 JUL 21, 2020 9:17 AM RECONCILIATION WARNING LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 0 2 PREMIUM 0 3 DIESEL 0 4 0 I63500 JUL 21, 2020 9:17 AM RECONCILIATION ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 1 2 PREMIUM 1 3 DIESEL 1 4 1 I63900 JUL 21, 2020 9:17 AM ACCU CHART END SHAPE FACTOR TANK PRODUCT LABEL 1 UNLEADED END FACTOR: NONE 2 PREMIUM END FACTOR: NONE 3 DIESEL END FACTOR: NONE 4 END FACTOR: NONE I78000 JUL 21, 2020 9:17 AM I77700 JUL 21, 2020 9:17 AM I77800 JUL 21, 2020 9:17 AM I78C00 JUL 21, 2020 9:17 AM I78300 JUL 21, 2020 9:17 AM I78F00 JUL 21, 2020 9:17 AM I78700 JUL 21, 2020 9:17 AM I70200 JUL 21, 2020 9:17 AM LIQUID LABEL DEVICE LABEL 1 UNL STP 2 UNL ANN 3 UNL FILL 4 PREM STP 5 PREM ANN 6 PREM FILL 7 DIESEL STP 8 DIESEL ANN 9 DIESEL FILL 10 DISP 1-2 11 DISP 3-4 12 DISP 5-6 13 DISP 7-8 14 15 16 I70300 JUL 21, 2020 9:17 AM LIQUID TYPE SENSOR LOCATION TYPE 1 UNL STP TRI-STATE (SINGLE FLOAT) 2 UNL ANN TRI-STATE (SINGLE FLOAT) 3 UNL FILL TRI-STATE (SINGLE FLOAT) 4 PREM STP TRI-STATE (SINGLE FLOAT) 5 PREM ANN TRI-STATE (SINGLE FLOAT) 6 PREM FILL TRI-STATE (SINGLE FLOAT) 7 DIESEL STP TRI-STATE (SINGLE FLOAT) 8 DIESEL ANN TRI-STATE (SINGLE FLOAT) 9 DIESEL FILL TRI-STATE (SINGLE FLOAT) 10 DISP 1-2 TRI-STATE (SINGLE FLOAT) 11 DISP 3-4 TRI-STATE (SINGLE FLOAT) 12 DISP 5-6 TRI-STATE (SINGLE FLOAT) 13 DISP 7-8 TRI-STATE (SINGLE FLOAT) 14 TRI-STATE (SINGLE FLOAT) 15 TRI-STATE (SINGLE FLOAT) 16 TRI-STATE (SINGLE FLOAT) I70400 JUL 21, 2020 9:17 AM LIQUID CATEGORY SENSOR LOCATION CATEGORY 1 UNL STP STP SUMP 2 UNL ANN ANNULAR SPACE 3 UNL FILL OTHER SENSORS 4 PREM STP STP SUMP 5 PREM ANN ANNULAR SPACE 6 PREM FILL OTHER SENSORS 7 DIESEL STP STP SUMP 8 DIESEL ANN ANNULAR SPACE 9 DIESEL FILL OTHER SENSORS 10 DISP 1-2 DISPENSER PAN 11 DISP 3-4 DISPENSER PAN 12 DISP 5-6 DISPENSER PAN 13 DISP 7-8 DISPENSER PAN 14 OTHER SENSORS 15 OTHER SENSORS 16 OTHER SENSORS I74200 JUL 21, 2020 9:17 AM 2 WIRE CL LABEL DEVICE LABEL 1 PREM ANN 2 3 4 5 6 7 8 I74300 JUL 21, 2020 9:17 AM 2 WIRE CL TYPE SENSOR LOCATION TYPE 1 PREM ANN ULTRA 2 2 ULTRA 2 3 ULTRA 2 4 ULTRA 2 5 ULTRA 2 6 ULTRA 2 7 ULTRA 2 8 ULTRA 2 I74400 JUL 21, 2020 9:17 AM 2 WIRE CL CATEGORY SENSOR LOCATION CATEGORY 1 PREM ANN ANNULAR SPACE 2 OTHER SENSORS 3 OTHER SENSORS 4 OTHER SENSORS 5 OTHER SENSORS 6 OTHER SENSORS 7 OTHER SENSORS 8 OTHER SENSORS I74700 JUL 21, 2020 9:17 AM I74800 JUL 21, 2020 9:17 AM I74900 JUL 21, 2020 9:17 AM I7BC00 JUL 21, 2020 9:17 AM I80200 JUL 21, 2020 9:17 AM I80300 JUL 21, 2020 9:17 AM I80400 JUL 21, 2020 9:17 AM I80700 JUL 21, 2020 9:17 AM RELAY LABEL DEVICE LABEL 1 UNLEADED 2 PREMIUM 3 DIESEL 4 OVERFILL ALARM I80900 JUL 21, 2020 9:17 AM RELAY ORIENTATION RELAY DESIGNATION ORIENTATION 1 UNLEADED NORMALLY OPEN 2 PREMIUM NORMALLY OPEN 3 DIESEL NORMALLY CLOSED 4 OVERFILL ALARM NORMALLY OPEN I80B00 JUL 21, 2020 9:17 AM RELAY TANK ASSIGNMENT RELAY DESIGNATION TANK 1 UNLEADED 1 2 PREMIUM 2 3 DIESEL 3 4 OVERFILL ALARM NONE I80A00 JUL 21, 2020 9:17 AM RELAY TYPE RELAY DESIGNATION TYPE 1 UNLEADED PUMP CONTROL OUTPUT 2 PREMIUM PUMP CONTROL OUTPUT 3 DIESEL STANDARD 4 OVERFILL ALARM STANDARD I80C00 JUL 21, 2020 9:17 AM I80800 JUL 21, 2020 9:17 AM RELAY SETUP REPORT R 1:UNLEADED TYPE: PUMP CONTROL OUTPUT TANK #: 1 LIQUID SENSOR ALMS L 1:FUEL ALARM L10:FUEL ALARM L11:FUEL ALARM L12:FUEL ALARM L13:FUEL ALARM L 1:SENSOR OUT ALARM L10:SENSOR OUT ALARM L11:SENSOR OUT ALARM L12:SENSOR OUT ALARM L13:SENSOR OUT ALARM L 1:SHORT ALARM L10:SHORT ALARM L11:SHORT ALARM L12:SHORT ALARM L13:SHORT ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD VP PRES FAIL ISD VP STATUS FAIL ISD SETUP FAIL ISD SENSOR OUT FAIL ISD HOSE ALARMS ALL:GROSS COLLECT FAIL ALL:DEGRD COLLECT FAIL ALL:FLOW COLLECT FAIL R 2:PREMIUM TYPE: PUMP CONTROL OUTPUT TANK #: 2 LIQUID SENSOR ALMS L 4:FUEL ALARM L10:FUEL ALARM L11:FUEL ALARM L12:FUEL ALARM L13:FUEL ALARM L 4:SENSOR OUT ALARM L10:SENSOR OUT ALARM L11:SENSOR OUT ALARM L12:SENSOR OUT ALARM L13:SENSOR OUT ALARM L 4:SHORT ALARM L10:SHORT ALARM L11:SHORT ALARM L12:SHORT ALARM L13:SHORT ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD VP PRES FAIL ISD VP STATUS FAIL ISD SETUP FAIL ISD SENSOR OUT FAIL ISD HOSE ALARMS ALL:GROSS COLLECT FAIL ALL:DEGRD COLLECT FAIL ALL:FLOW COLLECT FAIL R 3:DIESEL TYPE: STANDARD NORMALLY CLOSED TANK #: 3 LIQUID SENSOR ALMS L 7:FUEL ALARM L10:FUEL ALARM L11:FUEL ALARM L12:FUEL ALARM L13:FUEL ALARM L 7:SENSOR OUT ALARM L10:SENSOR OUT ALARM L11:SENSOR OUT ALARM L12:SENSOR OUT ALARM L13:SENSOR OUT ALARM L 7:SHORT ALARM L10:SHORT ALARM L11:SHORT ALARM L12:SHORT ALARM L13:SHORT ALARM R 4:OVERFILL ALARM TYPE: STANDARD NORMALLY OPEN TANK #: NONE IN-TANK ALARMS ALL:OVERFILL ALARM ALL:HIGH PRODUCT ALARM ALL:MAX PRODUCT ALARM I79000 JUL 21, 2020 9:18 AM EDIM:1 VR:349634-003-C TD:06.05.11.11.15 I79100 JUL 21, 2020 9:18 AM I72300 JUL 21, 2020 9:18 AM FASTRIP 705 1200 COFFEE RD. BAKERSFIELD CB 93308 661-589-6305 SMARTSENSOR ASSIGNMENT DEVICE LABEL CATEGORY 01 P.S.DISP 3-4 VAPOR PRESSURE 02 F.M. DISP 1-2 AIR FLOW METER 03 F.M. DISP 3-4 AIR FLOW METER 04 F.M. DISP 5-6 AIR FLOW METER 05 F.M. DISP 7-8 AIR FLOW METER 06 UNKNOWN 07 UNKNOWN 08 UNKNOWN 09 UNKNOWN 10 UNKNOWN 11 UNKNOWN 12 UNKNOWN 13 UNKNOWN 14 UNKNOWN 15 UNKNOWN 16 UNKNOWN 17 UNKNOWN 18 UNKNOWN 19 UNKNOWN 20 UNKNOWN 21 UNKNOWN 22 UNKNOWN 23 UNKNOWN 24 UNKNOWN 25 UNKNOWN 26 UNKNOWN 27 UNKNOWN 28 UNKNOWN 29 UNKNOWN 30 UNKNOWN 31 UNKNOWN 32 UNKNOWN 33 UNKNOWN 34 UNKNOWN 35 UNKNOWN 36 UNKNOWN 37 UNKNOWN 38 UNKNOWN 39 UNKNOWN 40 UNKNOWN IV4E00 JUL 21, 2020 9:18 AM FASTRIP 705 1200 COFFEE RD. BAKERSFIELD CB 93308 661-589-6305 EVR/ISD SETUP TYPE: VACUUM ASSIST VACUUM ASSIST TYPE: HEALY VAC IV4F00 JUL 21, 2020 9:18 AM FASTRIP 705 1200 COFFEE RD. BAKERSFIELD CB 93308 661-589-6305 NOZZLE A/L RANGE A/L RATIO: 0.95 - 1.15 IV4000 JUL 21, 2020 9:18 AM FASTRIP 705 1200 COFFEE RD. BAKERSFIELD CB 93308 661-589-6305 VAPOR PROCESSOR TYPE NO VAPOR PROCESSOR IV4700 JUL 21, 2020 9:18 AM FASTRIP 705 1200 COFFEE RD. BAKERSFIELD CB 93308 661-589-6305 ASSESSMENT TIME START TIME: 10:00 AM TIME DELAY MINUTES: 1 IV5200 JUL 21, 2020 9:18 AM FASTRIP 705 1200 COFFEE RD. BAKERSFIELD CB 93308 661-589-6305 ACCEPT HIGH ORVR: NO IV4A00 JUL 21, 2020 9:18 AM FASTRIP 705 1200 COFFEE RD. BAKERSFIELD CB 93308 661-589-6305 ISD HOSE TABLE HOSE FP FP AFM HOSE ID ID LABEL ID LABEL 01 01 01 01 BLEND3 02 02 02 01 BLEND3 03 03 03 02 BLEND3 04 04 04 02 BLEND3 05 05 05 03 BLEND3 06 06 06 03 BLEND3 07 07 07 04 BLEND3 08 08 08 04 BLEND3 IV4B00 JUL 21, 2020 9:18 AM FASTRIP 705 1200 COFFEE RD. BAKERSFIELD CB 93308 661-589-6305 PRODUCT/HOSE MAP TABLE FP AFID M1/H1 M2/H2 M3/H3 M4/H4 01 01 02/01 03/01 09/01 xx/xx 02 01 02/02 03/02 09/02 xx/xx 03 02 02/03 03/03 09/03 xx/xx 04 02 02/04 03/04 09/04 xx/xx 05 03 02/05 03/05 09/05 xx/xx 06 03 02/06 03/06 09/06 xx/xx 07 04 02/07 03/07 09/07 xx/xx 08 04 02/08 03/08 09/08 xx/xx IV4900 JUL 21, 2020 9:18 AM FASTRIP 705 1200 COFFEE RD. BAKERSFIELD CB 93308 661-589-6305 LABEL TABLE ID LABEL 01 UNASSIGNED 02 BLEND3 03 REGULAR 04 MID GRADE 05 PREMIUM 06 GOLD 07 BRONZE 08 SILVER 09 BLEND2 10 BLEND4 IV1000 JUL 21, 2020 9:18 AM ISD VERSION: 01.01 Jaco 7705 Alarm History Responses Received: I10200 JUL 21, 2020 9:19 AM FASTRIP 705 1200 COFFEE RD. BAKERSFIELD CB 93308 661-589-6305 SYSTEM CONFIGURATION SLOT BOARD TYPE POWER ON RESET CURRENT 1 7SMARTSENSOR BD 506765 505364 2 4 PROBE / G.T. 163158 163160 3 INTERSTITIAL BD 201390 201190 4 INTERSTITIAL BD 200817 200629 5 2 WIRE CL 68331 68300 6 UNUSED 10046671 9893216 7 UNUSED 10024087 9877662 8 UNUSED 10027144 9876150 9 STP SENSE BOARD 33153 33162 10 RELAY BOARD 14864 14910 11 UNUSED 10031081 9888666 12 UNUSED 10019544 9880817 13 UNUSED 10018240 9879015 14 UNUSED 10017914 9881542 15 UNUSED 10018627 9874086 16 UNUSED 10015611 9886264 COMM 1 RS232 SERIAL BD 14926 14952 COMM 2 ELEC DISP INT. 101028 101074 COMM 3 RS232 SERIAL BD 14987 14993 COMM 4 UNUSED 10030367 9885539 COMM 5 UNUSED 10017669 9874873 COMM 6 UNUSED 10021338 9871870 I90200 JUL 21, 2020 9:19 AM SOFTWARE REVISION LEVEL VERSION 327.04 SOFTWARE# 346327-100-E CREATED - 07.02.06.10.28 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD PMC I11100 JUL 21, 2020 9:19 AM FASTRIP 705 1200 COFFEE RD. BAKERSFIELD CB 93308 661-589-6305 PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME T 1 TANK UNLEADED PROBE OUT CLEAR 6-24-20 10:02AM T 1 TANK UNLEADED PROBE OUT ALARM 6-24-20 10:01AM T 2 TANK PREMIUM PROBE OUT CLEAR 6-24-20 10:01AM T 2 TANK PREMIUM OVERFILL ALARM CLEAR 6-24-20 10:00AM T 2 TANK PREMIUM PROBE OUT ALARM 6-24-20 10:00AM T 2 TANK PREMIUM OVERFILL ALARM ALARM 6-24-20 10:00AM T 2 TANK PREMIUM SUDDEN LOSS ALARM CLEAR 6-24-20 10:00AM T 3 TANK DIESEL PROBE OUT CLEAR 6-24-20 9:59AM T 3 TANK DIESEL OVERFILL ALARM CLEAR 6-24-20 9:59AM T 3 TANK DIESEL PROBE OUT ALARM 6-24-20 9:59AM T 3 TANK DIESEL OVERFILL ALARM ALARM 6-24-20 9:59AM T 3 TANK DIESEL PROBE OUT CLEAR 6-24-20 9:51AM T 3 TANK DIESEL PROBE OUT ALARM 6-24-20 9:51AM T 2 TANK PREMIUM PROBE OUT CLEAR 6-24-20 9:50AM T 2 TANK PREMIUM PROBE OUT ALARM 6-24-20 9:50AM T 1 TANK UNLEADED PROBE OUT CLEAR 6-24-20 9:50AM T 2 TANK PREMIUM SUDDEN LOSS ALARM ALARM 6-24-20 9:49AM T 1 TANK UNLEADED PROBE OUT ALARM 6-24-20 9:48AM L 7 STP SUMP DIESEL STP SENSOR OUT ALARM CLEAR 6-24-20 9:45AM L 6 OTHER PREM FILL SENSOR OUT ALARM CLEAR 6-24-20 9:45AM L 4 STP SUMP PREM STP SENSOR OUT ALARM CLEAR 6-24-20 9:45AM L 3 OTHER UNL FILL SENSOR OUT ALARM CLEAR 6-24-20 9:45AM L 2 ANNULAR UNL ANN SENSOR OUT ALARM CLEAR 6-24-20 9:45AM L 8 ANNULAR DIESEL ANN SENSOR OUT ALARM CLEAR 6-24-20 9:45AM L12 DISP PAN DISP 5-6 SENSOR OUT ALARM CLEAR 6-24-20 9:45AM L11 DISP PAN DISP 3-4 SENSOR OUT ALARM CLEAR 6-24-20 9:45AM L10 DISP PAN DISP 1-2 SENSOR OUT ALARM CLEAR 6-24-20 9:45AM L 1 STP SUMP UNL STP SENSOR OUT ALARM CLEAR 6-24-20 9:45AM L13 DISP PAN DISP 7-8 SENSOR OUT ALARM CLEAR 6-24-20 9:45AM L 9 OTHER DIESEL FILL SENSOR OUT ALARM CLEAR 6-24-20 9:45AM C 1 ANNULAR PREM ANN SENSOR OUT ALARM CLEAR 6-24-20 9:45AM L10 DISP PAN DISP 1-2 SENSOR OUT ALARM ALARM 6-24-20 9:45AM L11 DISP PAN DISP 3-4 SENSOR OUT ALARM ALARM 6-24-20 9:45AM L12 DISP PAN DISP 5-6 SENSOR OUT ALARM ALARM 6-24-20 9:45AM L 9 OTHER DIESEL FILL SENSOR OUT ALARM ALARM 6-24-20 9:45AM L 3 OTHER UNL FILL SENSOR OUT ALARM ALARM 6-24-20 9:45AM C 1 ANNULAR PREM ANN SENSOR OUT ALARM ALARM 6-24-20 9:45AM L 2 ANNULAR UNL ANN SENSOR OUT ALARM ALARM 6-24-20 9:44AM L13 DISP PAN DISP 7-8 SENSOR OUT ALARM ALARM 6-24-20 9:44AM L 8 ANNULAR DIESEL ANN SENSOR OUT ALARM ALARM 6-24-20 9:44AM L 7 STP SUMP DIESEL STP SENSOR OUT ALARM ALARM 6-24-20 9:44AM L 6 OTHER PREM FILL SENSOR OUT ALARM ALARM 6-24-20 9:44AM L 4 STP SUMP PREM STP SENSOR OUT ALARM ALARM 6-24-20 9:44AM L 1 STP SUMP UNL STP SENSOR OUT ALARM ALARM 6-24-20 9:44AM L10 DISP PAN DISP 1-2 FUEL ALARM CLEAR 6-24-20 9:41AM L10 DISP PAN DISP 1-2 FUEL ALARM ALARM 6-24-20 9:40AM L12 DISP PAN DISP 5-6 FUEL ALARM CLEAR 6-24-20 9:40AM L12 DISP PAN DISP 5-6 FUEL ALARM ALARM 6-24-20 9:40AM L13 DISP PAN DISP 7-8 FUEL ALARM CLEAR 6-24-20 9:39AM L13 DISP PAN DISP 7-8 FUEL ALARM ALARM 6-24-20 9:39AM I11200 JUL 21, 2020 9:19 AM FASTRIP 705 1200 COFFEE RD. BAKERSFIELD CB 93308 661-589-6305 NON-PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME T 1 TANK UNLEADED HIGH PRODUCT ALARM CLEAR 6-24-20 10:02AM T 1 TANK UNLEADED HIGH PRODUCT ALARM ALARM 6-24-20 10:01AM T 2 TANK PREMIUM HIGH PRODUCT ALARM CLEAR 6-24-20 10:01AM T 2 TANK PREMIUM HIGH PRODUCT ALARM ALARM 6-24-20 10:00AM T 3 TANK DIESEL DELIVERY NEEDED CLEAR 6-24-20 9:51AM T 3 TANK DIESEL DELIVERY NEEDED ALARM 6-24-20 9:51AM T 2 TANK PREMIUM DELIVERY NEEDED CLEAR 6-24-20 9:50AM T 2 TANK PREMIUM DELIVERY NEEDED ALARM 6-24-20 9:50AM SYSTEM PRINTER ERROR CLEAR 6-23-20 2:10PM SYSTEM PAPER OUT CLEAR 6-23-20 2:10PM SYSTEM PRINTER ERROR ALARM 6-23-20 2:08PM SYSTEM PAPER OUT ALARM 6-23-20 2:08PM T 1 TANK UNLEADED DELIVERY NEEDED CLEAR 6-22-20 9:16PM T 1 TANK UNLEADED DELIVERY NEEDED ALARM 6-22-20 7:08PM T 1 TANK UNLEADED DELIVERY NEEDED CLEAR 6-02-20 10:33AM T 1 TANK UNLEADED DELIVERY NEEDED ALARM 6-02-20 9:32AM T 1 TANK UNLEADED DELIVERY NEEDED CLEAR 5-27-20 2:50PM T 1 TANK UNLEADED DELIVERY NEEDED ALARM 5-27-20 2:16PM SYSTEM PRINTER ERROR CLEAR 5-18-20 7:15AM SYSTEM PAPER OUT CLEAR 5-18-20 7:15AM SYSTEM PRINTER ERROR ALARM 5-18-20 7:13AM SYSTEM PAPER OUT ALARM 5-18-20 7:13AM SYSTEM PRINTER ERROR CLEAR 5-18-20 12:56AM SYSTEM PAPER OUT CLEAR 5-18-20 12:56AM SYSTEM PRINTER ERROR ALARM 5-18-20 12:56AM SYSTEM PAPER OUT ALARM 5-18-20 12:56AM SYSTEM PRINTER ERROR CLEAR 5-18-20 12:56AM SYSTEM PAPER OUT CLEAR 5-18-20 12:56AM SYSTEM PRINTER ERROR ALARM 5-18-20 12:56AM SYSTEM PAPER OUT ALARM 5-18-20 12:56AM SYSTEM PRINTER ERROR CLEAR 5-18-20 12:56AM SYSTEM PRINTER ERROR ALARM 5-18-20 12:56AM SYSTEM PRINTER ERROR CLEAR 5-18-20 12:47AM SYSTEM PAPER OUT CLEAR 5-18-20 12:47AM SYSTEM PRINTER ERROR ALARM 5-18-20 12:47AM SYSTEM PAPER OUT ALARM 5-18-20 12:47AM SYSTEM PRINTER ERROR CLEAR 5-18-20 12:47AM SYSTEM PAPER OUT CLEAR 5-18-20 12:47AM SYSTEM PRINTER ERROR ALARM 5-18-20 12:43AM SYSTEM PAPER OUT ALARM 5-18-20 12:43AM SYSTEM PRINTER ERROR CLEAR 5-17-20 2:43AM SYSTEM PAPER OUT CLEAR 5-17-20 2:43AM SYSTEM PRINTER ERROR ALARM 5-17-20 2:43AM SYSTEM PAPER OUT ALARM 5-17-20 2:43AM T 1 TANK UNLEADED DELIVERY NEEDED CLEAR 5-11-20 7:27PM T 1 TANK UNLEADED INVALID FUEL LEVEL CLEAR 5-11-20 7:25PM SYSTEM PRINTER ERROR CLEAR 5-11-20 7:20PM SYSTEM PAPER OUT CLEAR 5-11-20 7:20PM SYSTEM PRINTER ERROR ALARM 5-11-20 7:20PM SYSTEM PAPER OUT ALARM 5-11-20 7:20PM I20600 JUL 21, 2020 9:20 AM FASTRIP 705 1200 COFFEE RD. BAKERSFIELD CB 93308 661-589-6305 TANK ALARM HISTORY TANK 1 UNLEADED OVERFILL ALARM JUN 11, 2020 1:49 PM MAR 28, 2020 9:08 AM HIGH PRODUCT ALARM JUN 24, 2020 10:01 AM INVALID FUEL LEVEL MAY 11, 2020 6:13 PM PROBE OUT JUN 24, 2020 10:01 AM JUN 24, 2020 9:48 AM DELIVERY NEEDED JUN 22, 2020 7:08 PM JUN 2, 2020 9:32 AM MAY 27, 2020 2:16 PM TANK 2 PREMIUM OVERFILL ALARM JUN 24, 2020 10:00 AM SUDDEN LOSS ALARM JUN 24, 2020 9:49 AM HIGH PRODUCT ALARM JUN 24, 2020 10:00 AM PROBE OUT JUN 24, 2020 10:00 AM JUN 24, 2020 9:50 AM DELIVERY NEEDED JUN 24, 2020 9:50 AM TANK 3 DIESEL OVERFILL ALARM JUN 24, 2020 9:59 AM PROBE OUT JUN 24, 2020 9:59 AM JUN 24, 2020 9:51 AM DELIVERY NEEDED JUN 24, 2020 9:51 AM I38200 JUL 21, 2020 9:20 AM I30200 JUL 21, 2020 9:20 AM FASTRIP 705 1200 COFFEE RD. BAKERSFIELD CB 93308 661-589-6305 LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 UNL STP JUN 24, 2020 9:44 AM SENSOR OUT ALARM JUN 24, 2020 9:37 AM FUEL ALARM FEB 25, 2020 9:21 AM SENSOR OUT ALARM 2 UNL ANN JUN 24, 2020 9:44 AM SENSOR OUT ALARM JUN 24, 2020 9:34 AM FUEL ALARM FEB 25, 2020 9:21 AM SENSOR OUT ALARM 3 UNL FILL JUN 24, 2020 9:45 AM SENSOR OUT ALARM JUN 24, 2020 9:33 AM FUEL ALARM MAY 18, 2020 7:07 PM FUEL ALARM 4 PREM STP JUN 24, 2020 9:44 AM SENSOR OUT ALARM JUN 24, 2020 9:36 AM FUEL ALARM FEB 25, 2020 9:21 AM SENSOR OUT ALARM 6 PREM FILL JUN 24, 2020 9:44 AM SENSOR OUT ALARM JUN 24, 2020 9:33 AM FUEL ALARM APR 9, 2020 9:41 AM FUEL ALARM 7 DIESEL STP JUN 24, 2020 9:44 AM SENSOR OUT ALARM JUN 24, 2020 9:36 AM FUEL ALARM MAY 9, 2020 3:06 PM FUEL ALARM 8 DIESEL ANN JUN 24, 2020 9:44 AM SENSOR OUT ALARM JUN 24, 2020 9:35 AM FUEL ALARM FEB 25, 2020 9:21 AM SENSOR OUT ALARM 9 DIESEL FILL JUN 24, 2020 9:45 AM SENSOR OUT ALARM JUN 24, 2020 9:34 AM FUEL ALARM APR 7, 2020 11:59 PM FUEL ALARM 10 DISP 1-2 JUN 24, 2020 9:45 AM SENSOR OUT ALARM JUN 24, 2020 9:40 AM FUEL ALARM FEB 25, 2020 9:21 AM SENSOR OUT ALARM 11 DISP 3-4 JUN 24, 2020 9:45 AM SENSOR OUT ALARM JUN 24, 2020 9:38 AM FUEL ALARM FEB 25, 2020 9:21 AM SENSOR OUT ALARM 12 DISP 5-6 JUN 24, 2020 9:45 AM SENSOR OUT ALARM JUN 24, 2020 9:40 AM FUEL ALARM FEB 25, 2020 9:21 AM SENSOR OUT ALARM 13 DISP 7-8 JUN 24, 2020 9:44 AM SENSOR OUT ALARM JUN 24, 2020 9:39 AM FUEL ALARM FEB 25, 2020 9:21 AM SENSOR OUT ALARM I31600 JUL 21, 2020 9:20 AM FASTRIP 705 1200 COFFEE RD. BAKERSFIELD CB 93308 661-589-6305 SMART SENSOR ALARM HISTORY REPORT SENSOR LOCATION 1 P.S.DISP 3-4 2 F.M. DISP 1-2 3 F.M. DISP 3-4 4 F.M. DISP 5-6 5 F.M. DISP 7-8 I40200 JUL 21, 2020 9:20 AM I40300 JUL 21, 2020 9:20 AM I34200 JUL 21, 2020 9:20 AM FASTRIP 705 1200 COFFEE RD. BAKERSFIELD CB 93308 661-589-6305 2 WIRE CL ALARM HISTORY REPORT SENSOR LOCATION 1 PREM ANN JUN 24, 2020 9:45 AM SENSOR OUT ALARM JUN 24, 2020 9:35 AM FUEL ALARM FEB 25, 2020 9:22 AM SENSOR OUT ALARM I34700 JUL 21, 2020 9:20 AM IV0100 JUL 21, 2020 9:20 AM FASTRIP 705 1200 COFFEE RD. BAKERSFIELD CB 93308 661-589-6305 ISD ALARM STATUS REPORT EVR TYPE: VACUUM ASSIST ISD TYPE: 01.01 VAPOR PROCESSOR TYPE: NO VAPOR PROCESSOR OVERALL STATUS :PASS EVR VAPOR COLLECTION :PASS EVR VAPOR CONTAINMENT :PASS ISD MONITOR UP-TIME :100% STAGE I TRANSFERS: 0 of 0 NOTEST EVR/ISD PASS TIME :100% WARNING ALARMS DATE TIME DESCRIPTION READING VALUE 20-05-01 10:02:58 A/L RATIO GROSS BLOCKAGE FP 4 BLEND3 BLKD 20-02-10 10:02:53 A/L RATIO DEGRADATION FP 1 BLEND3 0.80 20-02-09 10:02:55 A/L RATIO DEGRADATION FP 1 BLEND3 0.80 20-02-08 10:02:49 A/L RATIO DEGRADATION FP 1 BLEND3 0.80 20-01-31 10:02:08 A/L RATIO GROSS BLOCKAGE FP 6 BLEND3 BLKD 20-01-15 10:02:05 A/L RATIO GROSS BLOCKAGE FP 2 BLEND3 BLKD 20-01-01 10:02:45 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 1.39 19-12-22 10:01:48 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 1.31 19-12-04 10:02:14 A/L RATIO DEGRADATION FP 7 BLEND3 0.78 19-12-02 10:02:15 A/L RATIO DEGRADATION FP 7 BLEND3 0.80 FAILURE ALARMS DATE TIME DESCRIPTION READING VALUE 17-10-19 10:02:03 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.38 17-09-28 10:02:21 A/L RATIO GROSS BLOCKAGE FP 6 BLEND3 BLKD 17-09-19 10:02:13 A/L RATIO GROSS BLOCKAGE FP 2 BLEND3 BLKD SHUTDOWN & MISCELLANEOUS EVENTS DATE TIME DESCRIPTION ACTION/NAME 20-06-24 10:03:09 READINESS ISD:PP EVR:PP ISD & EVR READY 20-06-24 09:44:27 READINESS ISD:PP EVR:NN EVR READINESS PENDING 20-06-24 09:44:27 ISD STARTUP 20-06-24 09:43:55 ISD SHUTDOWN 20-05-01 15:32:55 COLLECTION TEST HH04 GRADE TEST MANUALLY CLEARED 20-03-23 10:03:13 READINESS ISD:PP EVR:PP ISD & EVR READY 20-03-23 09:45:38 READINESS ISD:PP EVR:NN EVR READINESS PENDING 20-03-23 09:45:38 ISD STARTUP 20-03-23 09:45:32 ISD SHUTDOWN 20-03-08 03:00:00 TIME CHANGE DETECTED AT: 20-03-08 02:00:13 Jaco 7705 Alarm History After Responses Received: I10200 JUL 21, 2020 11:09 AM FASTRIP 705 1200 COFFEE RD. BAKERSFIELD CB 93308 661-589-6305 SYSTEM CONFIGURATION SLOT BOARD TYPE POWER ON RESET CURRENT 1 7SMARTSENSOR BD 506765 505564 2 4 PROBE / G.T. 163158 163017 3 INTERSTITIAL BD 201390 201262 4 INTERSTITIAL BD 200817 200616 5 2 WIRE CL 68331 68287 6 UNUSED 10046671 9880568 7 UNUSED 10024087 9879079 8 UNUSED 10027144 9870949 9 STP SENSE BOARD 33153 33148 10 RELAY BOARD 14864 14897 11 UNUSED 10031081 9878860 12 UNUSED 10019544 9870130 13 UNUSED 10018240 9870543 14 UNUSED 10017914 9866716 15 UNUSED 10018627 9867378 16 UNUSED 10015611 9864089 COMM 1 RS232 SERIAL BD 14926 14938 COMM 2 ELEC DISP INT. 101028 101024 COMM 3 RS232 SERIAL BD 14987 15000 COMM 4 UNUSED 10030367 9873895 COMM 5 UNUSED 10017669 9870502 COMM 6 UNUSED 10021338 9867937 I90200 JUL 21, 2020 11:09 AM SOFTWARE REVISION LEVEL VERSION 327.04 SOFTWARE# 346327-100-E CREATED - 07.02.06.10.28 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD PMC I11100 JUL 21, 2020 11:09 AM FASTRIP 705 1200 COFFEE RD. BAKERSFIELD CB 93308 661-589-6305 PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME T 3 TANK DIESEL PROBE OUT CLEAR 7-21-20 10:13AM T 3 TANK DIESEL PROBE OUT ALARM 7-21-20 10:13AM T 2 TANK PREMIUM PROBE OUT CLEAR 7-21-20 10:12AM T 2 TANK PREMIUM PROBE OUT ALARM 7-21-20 10:11AM T 1 TANK UNLEADED PROBE OUT CLEAR 7-21-20 10:10AM T 1 TANK UNLEADED PROBE OUT ALARM 7-21-20 10:10AM T 3 TANK DIESEL PROBE OUT CLEAR 7-21-20 10:08AM T 2 TANK PREMIUM PROBE OUT CLEAR 7-21-20 10:07AM T 3 TANK DIESEL PROBE OUT ALARM 7-21-20 10:07AM T 2 TANK PREMIUM PROBE OUT ALARM 7-21-20 10:07AM T 1 TANK UNLEADED PROBE OUT CLEAR 7-21-20 10:06AM T 1 TANK UNLEADED PROBE OUT ALARM 7-21-20 10:05AM L 6 OTHER PREM FILL SENSOR OUT ALARM CLEAR 7-21-20 10:01AM L 4 STP SUMP PREM STP SENSOR OUT ALARM CLEAR 7-21-20 10:01AM L 3 OTHER UNL FILL SENSOR OUT ALARM CLEAR 7-21-20 10:01AM L 2 ANNULAR UNL ANN SENSOR OUT ALARM CLEAR 7-21-20 10:01AM L 8 ANNULAR DIESEL ANN SENSOR OUT ALARM CLEAR 7-21-20 10:01AM L 7 STP SUMP DIESEL STP SENSOR OUT ALARM CLEAR 7-21-20 10:01AM L 1 STP SUMP UNL STP SENSOR OUT ALARM CLEAR 7-21-20 10:01AM L13 DISP PAN DISP 7-8 SENSOR OUT ALARM CLEAR 7-21-20 10:01AM L12 DISP PAN DISP 5-6 SENSOR OUT ALARM CLEAR 7-21-20 10:01AM L11 DISP PAN DISP 3-4 SENSOR OUT ALARM CLEAR 7-21-20 10:01AM L10 DISP PAN DISP 1-2 SENSOR OUT ALARM CLEAR 7-21-20 10:01AM L 9 OTHER DIESEL FILL SENSOR OUT ALARM CLEAR 7-21-20 10:01AM C 1 ANNULAR PREM ANN SENSOR OUT ALARM CLEAR 7-21-20 10:00AM L10 DISP PAN DISP 1-2 SENSOR OUT ALARM ALARM 7-21-20 10:00AM L 8 ANNULAR DIESEL ANN SENSOR OUT ALARM ALARM 7-21-20 10:00AM L 7 STP SUMP DIESEL STP SENSOR OUT ALARM ALARM 7-21-20 10:00AM L 6 OTHER PREM FILL SENSOR OUT ALARM ALARM 7-21-20 10:00AM L12 DISP PAN DISP 5-6 SENSOR OUT ALARM ALARM 7-21-20 10:00AM L11 DISP PAN DISP 3-4 SENSOR OUT ALARM ALARM 7-21-20 10:00AM L 9 OTHER DIESEL FILL SENSOR OUT ALARM ALARM 7-21-20 10:00AM L 4 STP SUMP PREM STP SENSOR OUT ALARM ALARM 7-21-20 10:00AM L 3 OTHER UNL FILL SENSOR OUT ALARM ALARM 7-21-20 10:00AM C 1 ANNULAR PREM ANN SENSOR OUT ALARM ALARM 7-21-20 10:00AM L 2 ANNULAR UNL ANN SENSOR OUT ALARM ALARM 7-21-20 10:00AM L13 DISP PAN DISP 7-8 SENSOR OUT ALARM ALARM 7-21-20 9:59AM L 1 STP SUMP UNL STP SENSOR OUT ALARM ALARM 7-21-20 9:59AM L 9 OTHER DIESEL FILL FUEL ALARM CLEAR 7-21-20 9:57AM L 9 OTHER DIESEL FILL FUEL ALARM ALARM 7-21-20 9:56AM L 6 OTHER PREM FILL FUEL ALARM CLEAR 7-21-20 9:56AM L 6 OTHER PREM FILL FUEL ALARM ALARM 7-21-20 9:56AM L 3 OTHER UNL FILL FUEL ALARM CLEAR 7-21-20 9:56AM L 3 OTHER UNL FILL FUEL ALARM ALARM 7-21-20 9:55AM L 2 ANNULAR UNL ANN FUEL ALARM CLEAR 7-21-20 9:55AM L 2 ANNULAR UNL ANN FUEL ALARM ALARM 7-21-20 9:54AM C 1 ANNULAR PREM ANN FUEL ALARM CLEAR 7-21-20 9:53AM C 1 ANNULAR PREM ANN FUEL ALARM ALARM 7-21-20 9:52AM L 8 ANNULAR DIESEL ANN FUEL ALARM CLEAR 7-21-20 9:51AM L 8 ANNULAR DIESEL ANN FUEL ALARM ALARM 7-21-20 9:50AM I11200 JUL 21, 2020 11:09 AM FASTRIP 705 1200 COFFEE RD. BAKERSFIELD CB 93308 661-589-6305 NON-PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME T 3 TANK DIESEL HIGH WATER WARNING CLEAR 7-21-20 10:15AM T 3 TANK DIESEL HIGH PRODUCT ALARM CLEAR 7-21-20 10:13AM T 3 TANK DIESEL HIGH PRODUCT ALARM ALARM 7-21-20 10:13AM T 3 TANK DIESEL HIGH WATER WARNING ALARM 7-21-20 10:11AM T 2 TANK PREMIUM HIGH PRODUCT ALARM CLEAR 7-21-20 10:11AM T 2 TANK PREMIUM HIGH PRODUCT ALARM ALARM 7-21-20 10:11AM T 1 TANK UNLEADED HIGH PRODUCT ALARM CLEAR 7-21-20 10:10AM T 1 TANK UNLEADED HIGH PRODUCT ALARM ALARM 7-21-20 10:10AM T 1 TANK UNLEADED HIGH PRODUCT ALARM CLEAR 6-24-20 10:02AM T 1 TANK UNLEADED HIGH PRODUCT ALARM ALARM 6-24-20 10:01AM T 2 TANK PREMIUM HIGH PRODUCT ALARM CLEAR 6-24-20 10:01AM T 2 TANK PREMIUM HIGH PRODUCT ALARM ALARM 6-24-20 10:00AM T 3 TANK DIESEL DELIVERY NEEDED CLEAR 6-24-20 9:51AM T 3 TANK DIESEL DELIVERY NEEDED ALARM 6-24-20 9:51AM T 2 TANK PREMIUM DELIVERY NEEDED CLEAR 6-24-20 9:50AM T 2 TANK PREMIUM DELIVERY NEEDED ALARM 6-24-20 9:50AM SYSTEM PRINTER ERROR CLEAR 6-23-20 2:10PM SYSTEM PAPER OUT CLEAR 6-23-20 2:10PM SYSTEM PRINTER ERROR ALARM 6-23-20 2:08PM SYSTEM PAPER OUT ALARM 6-23-20 2:08PM T 1 TANK UNLEADED DELIVERY NEEDED CLEAR 6-22-20 9:16PM T 1 TANK UNLEADED DELIVERY NEEDED ALARM 6-22-20 7:08PM T 1 TANK UNLEADED DELIVERY NEEDED CLEAR 6-02-20 10:33AM T 1 TANK UNLEADED DELIVERY NEEDED ALARM 6-02-20 9:32AM T 1 TANK UNLEADED DELIVERY NEEDED CLEAR 5-27-20 2:50PM T 1 TANK UNLEADED DELIVERY NEEDED ALARM 5-27-20 2:16PM SYSTEM PRINTER ERROR CLEAR 5-18-20 7:15AM SYSTEM PAPER OUT CLEAR 5-18-20 7:15AM SYSTEM PRINTER ERROR ALARM 5-18-20 7:13AM SYSTEM PAPER OUT ALARM 5-18-20 7:13AM SYSTEM PRINTER ERROR CLEAR 5-18-20 12:56AM SYSTEM PAPER OUT CLEAR 5-18-20 12:56AM SYSTEM PRINTER ERROR ALARM 5-18-20 12:56AM SYSTEM PAPER OUT ALARM 5-18-20 12:56AM SYSTEM PRINTER ERROR CLEAR 5-18-20 12:56AM SYSTEM PAPER OUT CLEAR 5-18-20 12:56AM SYSTEM PRINTER ERROR ALARM 5-18-20 12:56AM SYSTEM PAPER OUT ALARM 5-18-20 12:56AM SYSTEM PRINTER ERROR CLEAR 5-18-20 12:56AM SYSTEM PRINTER ERROR ALARM 5-18-20 12:56AM SYSTEM PRINTER ERROR CLEAR 5-18-20 12:47AM SYSTEM PAPER OUT CLEAR 5-18-20 12:47AM SYSTEM PRINTER ERROR ALARM 5-18-20 12:47AM SYSTEM PAPER OUT ALARM 5-18-20 12:47AM SYSTEM PRINTER ERROR CLEAR 5-18-20 12:47AM SYSTEM PAPER OUT CLEAR 5-18-20 12:47AM SYSTEM PRINTER ERROR ALARM 5-18-20 12:43AM SYSTEM PAPER OUT ALARM 5-18-20 12:43AM SYSTEM PRINTER ERROR CLEAR 5-17-20 2:43AM SYSTEM PAPER OUT CLEAR 5-17-20 2:43AM I20600 JUL 21, 2020 11:09 AM FASTRIP 705 1200 COFFEE RD. BAKERSFIELD CB 93308 661-589-6305 TANK ALARM HISTORY TANK 1 UNLEADED OVERFILL ALARM JUN 11, 2020 1:49 PM MAR 28, 2020 9:08 AM HIGH PRODUCT ALARM JUL 21, 2020 10:10 AM JUN 24, 2020 10:01 AM INVALID FUEL LEVEL MAY 11, 2020 6:13 PM PROBE OUT JUL 21, 2020 10:10 AM JUL 21, 2020 10:05 AM JUN 24, 2020 10:01 AM DELIVERY NEEDED JUN 22, 2020 7:08 PM JUN 2, 2020 9:32 AM MAY 27, 2020 2:16 PM TANK 2 PREMIUM OVERFILL ALARM JUN 24, 2020 10:00 AM SUDDEN LOSS ALARM JUN 24, 2020 9:49 AM HIGH PRODUCT ALARM JUL 21, 2020 10:11 AM JUN 24, 2020 10:00 AM PROBE OUT JUL 21, 2020 10:11 AM JUL 21, 2020 10:07 AM JUN 24, 2020 10:00 AM DELIVERY NEEDED JUN 24, 2020 9:50 AM TANK 3 DIESEL OVERFILL ALARM JUN 24, 2020 9:59 AM HIGH PRODUCT ALARM JUL 21, 2020 10:13 AM PROBE OUT JUL 21, 2020 10:13 AM JUL 21, 2020 10:07 AM JUN 24, 2020 9:59 AM HIGH WATER WARNING JUL 21, 2020 10:11 AM DELIVERY NEEDED JUN 24, 2020 9:51 AM I38200 JUL 21, 2020 11:09 AM I30200 JUL 21, 2020 11:09 AM FASTRIP 705 1200 COFFEE RD. BAKERSFIELD CB 93308 661-589-6305 LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 UNL STP JUL 21, 2020 9:59 AM SENSOR OUT ALARM JUL 21, 2020 9:47 AM FUEL ALARM JUN 24, 2020 9:44 AM SENSOR OUT ALARM 2 UNL ANN JUL 21, 2020 10:00 AM SENSOR OUT ALARM JUL 21, 2020 9:54 AM FUEL ALARM JUN 24, 2020 9:44 AM SENSOR OUT ALARM 3 UNL FILL JUL 21, 2020 10:00 AM SENSOR OUT ALARM JUL 21, 2020 9:55 AM FUEL ALARM JUN 24, 2020 9:45 AM SENSOR OUT ALARM 4 PREM STP JUL 21, 2020 10:00 AM SENSOR OUT ALARM JUL 21, 2020 9:48 AM FUEL ALARM JUN 24, 2020 9:44 AM SENSOR OUT ALARM 6 PREM FILL JUL 21, 2020 10:00 AM SENSOR OUT ALARM JUL 21, 2020 9:56 AM FUEL ALARM JUN 24, 2020 9:44 AM SENSOR OUT ALARM 7 DIESEL STP JUL 21, 2020 10:00 AM SENSOR OUT ALARM JUL 21, 2020 9:49 AM FUEL ALARM JUN 24, 2020 9:44 AM SENSOR OUT ALARM 8 DIESEL ANN JUL 21, 2020 10:00 AM SENSOR OUT ALARM JUL 21, 2020 9:50 AM FUEL ALARM JUN 24, 2020 9:44 AM SENSOR OUT ALARM 9 DIESEL FILL JUL 21, 2020 10:00 AM SENSOR OUT ALARM JUL 21, 2020 9:56 AM FUEL ALARM JUN 24, 2020 9:45 AM SENSOR OUT ALARM 10 DISP 1-2 JUL 21, 2020 10:00 AM SENSOR OUT ALARM JUL 21, 2020 9:44 AM FUEL ALARM JUN 24, 2020 9:45 AM SENSOR OUT ALARM 11 DISP 3-4 JUL 21, 2020 10:00 AM SENSOR OUT ALARM JUL 21, 2020 9:45 AM FUEL ALARM JUN 24, 2020 9:45 AM SENSOR OUT ALARM 12 DISP 5-6 JUL 21, 2020 10:00 AM SENSOR OUT ALARM JUL 21, 2020 9:44 AM FUEL ALARM JUN 24, 2020 9:45 AM SENSOR OUT ALARM 13 DISP 7-8 JUL 21, 2020 9:59 AM SENSOR OUT ALARM JUL 21, 2020 9:46 AM FUEL ALARM JUN 24, 2020 9:44 AM SENSOR OUT ALARM I31600 JUL 21, 2020 11:09 AM FASTRIP 705 1200 COFFEE RD. BAKERSFIELD CB 93308 661-589-6305 SMART SENSOR ALARM HISTORY REPORT SENSOR LOCATION 1 P.S.DISP 3-4 2 F.M. DISP 1-2 3 F.M. DISP 3-4 4 F.M. DISP 5-6 5 F.M. DISP 7-8 I40200 JUL 21, 2020 11:09 AM I40300 JUL 21, 2020 11:09 AM I34200 JUL 21, 2020 11:09 AM FASTRIP 705 1200 COFFEE RD. BAKERSFIELD CB 93308 661-589-6305 2 WIRE CL ALARM HISTORY REPORT SENSOR LOCATION 1 PREM ANN JUL 21, 2020 10:00 AM SENSOR OUT ALARM JUL 21, 2020 9:52 AM FUEL ALARM JUN 24, 2020 9:45 AM SENSOR OUT ALARM I34700 JUL 21, 2020 11:09 AM IV0100 JUL 21, 2020 11:09 AM FASTRIP 705 1200 COFFEE RD. BAKERSFIELD CB 93308 661-589-6305 ISD ALARM STATUS REPORT EVR TYPE: VACUUM ASSIST ISD TYPE: 01.01 VAPOR PROCESSOR TYPE: NO VAPOR PROCESSOR OVERALL STATUS :PASS EVR VAPOR COLLECTION :PASS EVR VAPOR CONTAINMENT :PASS ISD MONITOR UP-TIME : 99% STAGE I TRANSFERS: 0 of 0 NOTEST EVR/ISD PASS TIME :100% WARNING ALARMS DATE TIME DESCRIPTION READING VALUE 20-05-01 10:02:58 A/L RATIO GROSS BLOCKAGE FP 4 BLEND3 BLKD 20-02-10 10:02:53 A/L RATIO DEGRADATION FP 1 BLEND3 0.80 20-02-09 10:02:55 A/L RATIO DEGRADATION FP 1 BLEND3 0.80 20-02-08 10:02:49 A/L RATIO DEGRADATION FP 1 BLEND3 0.80 20-01-31 10:02:08 A/L RATIO GROSS BLOCKAGE FP 6 BLEND3 BLKD 20-01-15 10:02:05 A/L RATIO GROSS BLOCKAGE FP 2 BLEND3 BLKD 20-01-01 10:02:45 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 1.39 19-12-22 10:01:48 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 1.31 19-12-04 10:02:14 A/L RATIO DEGRADATION FP 7 BLEND3 0.78 19-12-02 10:02:15 A/L RATIO DEGRADATION FP 7 BLEND3 0.80 FAILURE ALARMS DATE TIME DESCRIPTION READING VALUE 17-10-19 10:02:03 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.38 17-09-28 10:02:21 A/L RATIO GROSS BLOCKAGE FP 6 BLEND3 BLKD 17-09-19 10:02:13 A/L RATIO GROSS BLOCKAGE FP 2 BLEND3 BLKD SHUTDOWN & MISCELLANEOUS EVENTS DATE TIME DESCRIPTION ACTION/NAME 20-07-21 10:02:55 READINESS ISD:PP EVR:PP ISD & EVR READY 20-07-21 09:59:10 READINESS ISD:PP EVR:NN EVR READINESS PENDING 20-07-21 09:59:10 ISD STARTUP 20-07-21 09:58:33 ISD SHUTDOWN 20-06-24 10:03:09 READINESS ISD:PP EVR:PP ISD & EVR READY 20-06-24 09:44:27 READINESS ISD:PP EVR:NN EVR READINESS PENDING 20-06-24 09:44:27 ISD STARTUP 20-06-24 09:43:55 ISD SHUTDOWN 20-05-01 15:32:55 COLLECTION TEST HH04 GRADE TEST MANUALLY CLEARED 20-03-23 10:03:13 READINESS ISD:PP EVR:PP ISD & EVR READY &(56 &DOLIRUQLD(QYLURQPHQWDO5HSRUWLQJ6\VWHP,' ,GHQWLILFDWLRQ867 8QGHUJURXQG6WRUDJH7DQN,&& ,QWHUQDWLRQDO&RGH&RXQFLO 81 ZZZXQLGRFVRUJ5HY 81'(5*5281'6725$*(7$1. 63,//&217$,1(57(67,1*5(3257)250 3DJHRI  7\SHRI$FWLRQ,QVWDOODWLRQ7HVW5HSDLU7HVW0RQWK7HVW , )$&,/,7<,1)250$7,21 &(56,''DWHRI6SLOO&RQWDLQHU7HVW %XVLQHVV1DPH(Same as Facility Name or DBA-Doing Business As) %XVLQHVV6LWH$GGUHVV &LW\ =,3&RGH ,, 81'(5*5281'6725$*(7$1.6(59,&(7(&+1,&,$1,1)250$7,21 1DPHRI8676HUYLFH7HFKQLFLDQ3HUIRUPLQJWKH7HVW(Print as shown on the ICC Certification.) 3KRQH &RQWUDFWRU7DQN7HVWHU/LFHQVH ,&&&HUWLILFDWLRQ ,&&&HUWLILFDWLRQ([SLUDWLRQ'DWH 6SLOO&RQWDLQHU7HVWLQJ7UDLQLQJDQG&HUWLILFDWLRQV(List applicable certifications.) ,,, 63,//&217$,1(57(67,1*,1)250$7,21 7HVW0HWKRG8VHG0DQXIDFWXUHU*XLGHOLQHV(Specify) ,QGXVWU\&RGHRU(QJLQHHULQJ6WDQGDUG (Specify) (QJLQHHUHG0HWKRG(Specify) Attach the testing procedures and all documentation required to determine the results.RI$WWDFKHG3DJHV 7$1.,'(By tank number, stored product, etc.) 6SLOO&RQWDLQHU0DQXIDFWXUHU 0HWKRGRI&DWKRGLF3URWHFWLRQ1RQ0HWDOOLF1RQ0HWDOOLF1RQ0HWDOOLF1RQ0HWDOOLF ,VRODWLRQ,VRODWLRQ,VRODWLRQ,VRODWLRQ 2WKHU(Specify in V.)2WKHU(Specify in V.)2WKHU(Specify in V.)2WKHU(Specify in V.) ,QVLGH'LDPHWHURI6SLOO&RQWDLQHU(Inches) 'HSWKRI6SLOO&RQWDLQHU(Inches) 'RHVWKHVSLOOFRQWDLQHUKDYHDJDOORQFDSDFLW\"<HV1R<HV1R<HV1R<HV1R 0HWKRGWR.HHS6SLOO&RQWDLQHU(PSW\'UDLQ9DOYH'UDLQ9DOYH'UDLQ9DOYH'UDLQ9DOYH 2QVLWH3XPS2QVLWH3XPS2QVLWH3XPS2QVLWH3XPS 2WKHU(Specify in V.)2WKHU(Specify in V.)2WKHU(Specify in V.)2WKHU(Specify in V.) ,9 6800$5<2)7(67,1*5(68/76 6SLOO&RQWDLQHU7HVW5HVXOWV3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLO 9 &200(176 Any items marked “Fail” above must be explained in this section. Any additional comments may also be provided here. 9, &(57,),&$7,21%<8676(59,&(7(&+1,&,$1&21'8&7,1*7+,67(67,1* ,KHUHE\FHUWLI\WKDWWKHVSLOOFRQWDLQHUVZHUHWHVWHGLQDFFRUGDQFHZLWK&DOLIRUQLD&RGHRI5HJXODWLRQV7LWOH'LYLVLRQ &KDSWHU6HFWLRQDQGDOOWKHLQIRUPDWLRQFRQWDLQHGKHUHLQLVDFFXUDWH 8676HUYLFH7HFKQLFLDQ6LJQDWXUH If the facility has more components than this form accommodates, additional copies of this page may be attached. Bakersfield 93308 804904 8485827 2/25/2021 FFS 1010993708 PEI 1200 0 T1:87 PHILTITE 12.00” 15.00” T2:91 PHILTITE 12.00” 15.00” T:3 Diesel PHILTITE 12.00” 14.00” Aaron Perrigo (800) 339-9930 10133029 7/21/2020 Jaco #7705 Fastrip #641 1200 Coffee Rd