HomeMy WebLinkAboutFMC 2020Appendix VI Underground Storage Tank Monitoring System Certification Form CERS = California Environmental Reporting System, GPH = Gallons Per Hour, ID = Identification, ICC = International Code Council, LLD = Line Leak Detector, NA = Not Applicable, SW = Single- Walled, UDC = Under-Dispenser Containment, UST = Underground Storage Tank, VPH = Vacuum/Pressure/Hydrostatic Page 1 of 6 TYPE OF ACTION ܆܆ Installation ܆ Repair ܆ 12 Month 1. FACILITY INFORMATION CERS ID Certification Date Facility Name Facility Address City ZIP Code 2. SERVICE TECHNICIAN INFORMATION Company Performing the Certification Phone Mailing Address Service Technician Performing Test Contractor/Tank Tester License Number ICC Number ICC Expiration Date 3. TRAINING AND CERTIFICATIONS Manufacturer and Test Equipment Training Certifications Expiration Date 4. CERTIFICATION BY SERVICE TECHNICIAN CONDUCTING TEST I hereby certify that the monitoring system is operational in accordance with California Code of Regulations, title 23, division 3, chapter 16, section 2638; that required supporting documentation is attached; and all information contained herein is accurate. Service Technician Signature Date Total # of Pages 10123120 12/15/2020 Sparkling Image Car Wash (204) 2301 H Street Bakersfield 93301 Confidence UST Services, Inc.(800) 339-9930 16250 Meacham Road, Bakersfield, CA 93314 Payton Phillips 804904 9482312 1-30-2022 Veedor Root c27796 07-29-2022 FFS 1016783712 12-04-2022 12/15/2020 6 Underground Storage Tank Monitoring System Certification Form Page 2 of 6 5. MONITORING SYSTEM AND PROGRAMMING A separate Monitoring System Certification Form must be prepared for each control panel. Make of Monitoring System Control Panel Model of Monitoring System Control Panel Software Version Installed Attach the post-certification reports if the monitoring system is capable of generating either; ܆܆Monitoring System Set-up ܆܆ Alarm History Report Yes No NA All monitoring equipment is operational per manufacturer’s specifications? ܆܆܆܆ Secondary containment systems are free of damage, debris, or liquid? ܆܆܆܆ Are the audible and visual alarms operational? ܆܆܆܆ All sensors have been: 1) visually inspected for wiring kinks, breaks and residual buildup on floats; and 2) tested for functionality and confirmed operational? ܆܆܆܆܆܆ Are all sensors installed to detect a release at the earliest opportunity in the secondary containment? ܆܆܆܆܆܆ The monitoring system set-up was reviewed, and proper settings confirmed? ܆܆܆܆܆܆ Was the monitoring control panel’s backup battery visually inspected, functionally tested, and confirmed operational? ܆܆܆܆܆܆ Does the flow of fuel stop at the dispenser if a release is detected in the under- dispenser containment? ܆܆܆܆܆܆ Does the turbine automatically shut down if the piping secondary containment monitoring system fails to operate or is electrically disconnected? ܆܆܆܆܆܆ Does the turbine automatically shut down if the piping secondary containment monitoring system detects a release? Which sensors initiate positive shut down? (Check all that apply) ܆ Sump ܆ UDC ܆܆܆܆܆܆ If monitoring system alarms are relayed to a remote monitoring center, is all communication equipment operational? ܆܆܆܆܆܆ Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 Veedor Root TLS-350 336.00 Underground Storage Tank Monitoring System Certification Form Page 3 of 6 6. SENSOR TESTING RESULTS List only sensors tested on date of this certification. List “Sensor ID” as labeled in system programming. Additional copies of this page may be attached to accommodate all sensors tested. Sensor ID Sensor Model Component(s) Monitored Pass Fail ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 L1 794380-208 Dispenser 1-2 L2 794380-208 Dispenser 3-4 L3 794380-208 Dispenser 11-12 L4 794380-208 Dispenser 7-8 L5 794380-208 Dispenser 9-10 L6 794380-208 Dispenser 5-6 L7 794380-208 Dispenser 13-14 L8 794380-208 Dispenser 15-16 L9 794380-208 Unleaded sump L10 794380-208 Supreme sump L11 794380-208 Diesel sump L12 Mouser Vac Unleaded ann L13 Mouser Vac Supreme ann L14 Mouser Vac Diesel Ann. Underground Storage Tank Monitoring System Certification Form Page 4 of 6 7. LINE LEAK DETECTOR TESTING ܆܆ Check this box if line leak detectors ARE NOT installed. (Do not complete this section.) Simulated release rate verified: (Check all that apply.) ܆܆ 3 GPH ܆܆ 0.1 GPH ܆܆ 0.2 GPH Yes No NA Has the testing apparatus been properly calibrated? ܆܆ ܆܆ ܆܆ For emergency generator tank systems, does the LLD create an audible and visual alarm when a leak is detected? ܆܆ ܆܆ ܆܆ For mechanical LLDs, does the LLD restrict the flow through the pipe when a release is detected? ܆܆ ܆܆ ܆܆ For electronic LLDs, does the turbine automatically shut off when a release is detected? ܆܆ ܆܆ ܆܆ For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system is disabled or disconnected? ܆܆ ܆܆ ܆܆ For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system malfunctions or fails a tightness test? ܆܆ ܆܆ ܆܆ For electronic LLDs, have all accessible wiring connections been visually inspected for kinks and breaks? ܆܆ ܆܆ ܆܆ Were all items on the equipment manufacturer’s maintenance checklist completed? ܆܆ ܆܆ ܆܆ Were all LLDs confirmed operational within regulatory requirements? ܆܆ ܆܆ ܆܆ LLD ID LLD Model Lines Monitored Pass Fail ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 T1 FX1V 87 T2 FX1V 91 T3 FX1DV DSL Underground Storage Tank Monitoring System Certification Form Page 5 of 6 8. IN-TANK GAUGING TESTING ܆܆ Check this box if tank gauging is used only for inventory control. ܆܆ Check this box if NO tank gauging equipment is installed. (Do not complete this section if either box is checked.) Yes No NA All wiring has been: 1) visually inspected for kinks, breaks and proper entry and termination; and 2) tested for ground faults? ܆܆ ܆܆ ܆܆ Were all in-tank gauging probes visually inspected for damage and residue buildup to ensure that floats move freely, functionally tested, and confirmed operational? ܆܆ ܆܆ Was accuracy of system’s product level readings tested? ܆܆ ܆܆ ܆܆ Was accuracy of system’s water level readings tested? ܆܆ ܆܆ ܆܆ Were all probes reinstalled properly? ܆܆ ܆܆ ܆܆ Were all items on the equipment manufacturer’s maintenance checklist completed? ܆܆ ܆܆ ܆܆ Probe ID Probe Model Tanks Monitored Pass Fail ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ 9. COMMENTS Describe all answers marked “No” or “Fail” and proposed remedy. List all monitoring equipment either replaced or repaired. ܆܆ Had to replace 87 Ann Sensor. Was not working and was stuck in Fuel alarm. I replaced the sensor and got it to pass. Underground Storage Tank Monitoring System Certification Form Page 6 of 6 10. MONITORING SITE PLAN Date site plan was prepared: If a site plan has been prepared that shows all required information, you may include it, rather than this page, with your Monitoring System Certification Form. The site plan must show the general layout of tanks and identify locations of the monitoring panel, and all leak detection equipment and monitoring locations. Include a legend for all symbols depicted. 11-16-12 12/15/20 sparkling image mc SYSTEM SETUP Responses Received: 200 286917 SPARKLING IMA 2301 H ST. BAKERSFIELD,CA 93301 661-324-8455 DEC 15, 2020 11:17 AM TANK PRODUCT GALLONS INCHES WATER DEG F ULLAGE 1 UNLEADED 87 5770 46.56 0.0 61.8 6230 2 SUPREME 91 3980 35.15 0.0 61.8 8020 3 DIESEL 3987 35.20 0.0 70.4 8013 I90500 DEC 15, 2020 11:17 AM SOFTWARE REVISION LEVEL VERSION 336.00 SOFTWARE# 346336-100-A CREATED - 19.12.13.15.19 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS CSLD BIR FUEL MANAGER ISD/APM PLLD 0.10 AUTO 0.20 REPETITIV WPLLD 0.10 AUTO 0.20 REPETITIV I50500 DEC 15, 2020 11:17 AM SYSTEM TYPE AND LANGUAGE FLAG SYSTEM UNITS U.S. SYSTEM LANGUAGE ENGLISH SYSTEM DATE/TIME FORMAT MON DD YYYY HH:MM:SS xM I50201 DEC 15, 2020 11:17 AM SHIFT TIME 1 : 12:00 AM I50202 DEC 15, 2020 11:17 AM SHIFT TIME 2 : 6:00 AM I50203 DEC 15, 2020 11:17 AM SHIFT TIME 3 : 12:00 PM I50204 DEC 15, 2020 11:17 AM SHIFT TIME 4 : 6:00 PM I54600 DEC 15, 2020 11:17 AM TANK PER TST NEEDED WRN: DISABLED I54900 DEC 15, 2020 11:17 AM TANK ANN TST NEEDED WRN: DISABLED I55300 DEC 15, 2020 11:17 AM LINE RE-ENABLE METHOD PASS LINE TEST I55600 DEC 15, 2020 11:17 AM LINE PER TST NEEDED WRN: DISABLED I55900 DEC 15, 2020 11:17 AM LINE ANN TST NEEDED WRN: DISABLED I50D00 DEC 15, 2020 11:17 AM PRINT TC VOLUMES ENABLED I50E00 DEC 15, 2020 11:17 AM TEMP COMPENSATION VALUE (DEG F ): 60.0 I60B00 DEC 15, 2020 11:17 AM STICK HEIGHT OFFSET ENABLE STATUS DISABLED I51400 DEC 15, 2020 11:17 AM H-PROTOCOL DATA FORMAT HEIGHT I51A01 DEC 15, 2020 11:17 AM DAYLIGHT SAVING TIME ENABLED OFF I51B00 DEC 15, 2020 11:17 AM DAYLIGHT SAVING TIME START DATE MAR WEEK 2 SUN 2:00 AM END DATE NOV WEEK 1 SUN 2:00 AM I51600 DEC 15, 2020 11:17 AM RE-DIRECT LOCAL PRINTOUT DISABLED I50400 DEC 15, 2020 11:17 AM 232 SECURITY CODE PORT SECURITY CODE STATUS 1 000000 DISABLED 2 000000 DISABLED 3 000000 DISABLED 4 000000 DISABLED 5 000000 DISABLED 6 000000 DISABLED I21900 DEC 15, 2020 11:17 AM TANK CHART SECURITY DISABLED I5BD00 DEC 15, 2020 11:17 AM CUSTOM ALARM LABELS DISABLED I56000 DEC 15, 2020 11:17 AM MASS/DENSITY DISABLED I88101 DEC 15, 2020 11:17 AM PORT SETTINGS: COMM BOARD : 1 (EDIM ) RS-232 SECURITY CODE : DISABLED I88102 DEC 15, 2020 11:17 AM PORT SETTINGS: COMM BOARD : 2 (RS-232) BAUD RATE : 9600 PARITY : NONE STOP BIT : 1 STOP DATA LENGTH: 8 DATA RS-232 SECURITY CODE : DISABLED I88103 DEC 15, 2020 11:17 AM PORT SETTINGS: COMM BOARD : 3 (S-SAT ) BAUD RATE : 9600 PARITY : NONE STOP BIT : 1 STOP DATA LENGTH: 8 DATA RS-232 SECURITY CODE : DISABLED DTR NORMAL STATE: HIGH I88104 DEC 15, 2020 11:17 AM I88105 DEC 15, 2020 11:17 AM I88106 DEC 15, 2020 11:17 AM I52000 DEC 15, 2020 11:17 AM RECEIVER AUTO DIAL TYPE & START TIME RCVR LOCATION LABEL DIAL TYPE START TIME 1 WEEKLY SUN 9:30 PM 2 WEEKLY SUN 9:30 PM 3 WEEKLY SUN 9:30 PM 4 WEEKLY SUN 9:30 PM 5 WEEKLY SUN 9:30 PM 6 WEEKLY SUN 9:30 PM 7 WEEKLY SUN 9:30 PM 8 VEEDER ROOT (FMS) WEEKLY SUN 9:30 PM I60100 DEC 15, 2020 11:17 AM TANK CONFIGURATION DEVICE LABEL CONFIGURED 1 UNLEADED 87 ON 2 SUPREME 91 ON 3 DIESEL ON 4 OFF I60200 DEC 15, 2020 11:17 AM TANK PRODUCT LABEL TANK PRODUCT LABEL 1 UNLEADED 87 2 SUPREME 91 3 DIESEL 4 I60300 DEC 15, 2020 11:17 AM TANK PRODUCT CODE TANK PRODUCT LABEL 1 UNLEADED 87 1 2 SUPREME 91 2 3 DIESEL 3 4 4 I60900 DEC 15, 2020 11:17 AM TANK THERMAL COEFFICIENT TANK PRODUCT LABEL 1 UNLEADED 87 0.000700 2 SUPREME 91 0.000700 3 DIESEL 0.000450 4 0.000000 I60700 DEC 15, 2020 11:17 AM TANK DIAMETER TANK PRODUCT LABEL INCHES 1 UNLEADED 87 96.00 2 SUPREME 91 96.00 3 DIESEL 96.00 4 0.00 I60A00 DEC 15, 2020 11:17 AM TANK FULL VOLUME TANK PRODUCT LABEL TANK PROFILE GALLONS 1 UNLEADED 87 1 PT 12000 2 SUPREME 91 1 PT 12000 3 DIESEL 1 PT 12000 4 1 PT 0 I60400 DEC 15, 2020 11:17 AM TANK FULL VOLUME TANK PRODUCT LABEL GALLONS 1 UNLEADED 87 12000 2 SUPREME 91 12000 3 DIESEL 12000 4 0 I60500 DEC 15, 2020 11:17 AM TANK 4 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 UNLEADED 87 12000 0 0 0 2 SUPREME 91 12000 0 0 0 3 DIESEL 12000 0 0 0 4 0 0 0 0 I60600 DEC 15, 2020 11:17 AM TANK 20 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 UNLEADED 87 12000 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 SUPREME 91 12000 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3 DIESEL 12000 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 I61500 DEC 15, 2020 11:17 AM TANK PRODUCT LABEL METER DATA 1 UNLEADED 87 NO 2 SUPREME 91 NO 3 DIESEL NO 4 NO I62F00 DEC 15, 2020 11:17 AM MAG PROBE FLOAT SIZE TANK PRODUCT LABEL FLOAT SIZE: 1 UNLEADED 87 4.0 IN. 2 SUPREME 91 4.0 IN. 3 DIESEL 4.0 IN. I62700 DEC 15, 2020 11:17 AM TANK HIGH WATER WARNING LIMIT TANK PRODUCT LABEL INCHES 1 UNLEADED 87 2.0 2 SUPREME 91 2.0 3 DIESEL 2.0 I64200 DEC 15, 2020 11:17 AM WATER ALARM FILTER TANK PRODUCT LABEL 1 UNLEADED 87 LOW 2 SUPREME 91 LOW 3 DIESEL LOW I62400 DEC 15, 2020 11:17 AM TANK HIGH WATER LEVEL LIMIT TANK PRODUCT LABEL INCHES 1 UNLEADED 87 3.0 2 SUPREME 91 3.0 3 DIESEL 3.0 I62800 DEC 15, 2020 11:17 AM TANK MAXIMUM VOLUME LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 87 12000 2 SUPREME 91 12000 3 DIESEL 12000 4 0 I62300 DEC 15, 2020 11:17 AM TANK OVERFILL LEVEL LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 87 10800 2 SUPREME 91 10800 3 DIESEL 10800 4 0 I62200 DEC 15, 2020 11:17 AM TANK HIGH PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 87 11400 2 SUPREME 91 11400 3 DIESEL 11400 4 0 I62900 DEC 15, 2020 11:17 AM TANK DELIVERY REQUIRED LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 87 1200 2 SUPREME 91 1200 3 DIESEL 1200 4 0 I62100 DEC 15, 2020 11:17 AM TANK LOW PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 87 451 2 SUPREME 91 451 3 DIESEL 451 4 0 I62600 DEC 15, 2020 11:17 AM TANK LEAK ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 87 99 2 SUPREME 91 99 3 DIESEL 99 4 99 I62500 DEC 15, 2020 11:17 AM TANK SUDDEN LOSS LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 87 99 2 SUPREME 91 99 3 DIESEL 99 4 99 I60800 DEC 15, 2020 11:17 AM TANK TILT TANK PRODUCT LABEL INCHES 1 UNLEADED 87 -3.00 2 SUPREME 91 -2.00 3 DIESEL 0.00 4 0.00 I60B00 DEC 15, 2020 11:17 AM STICK HEIGHT OFFSET ENABLE STATUS DISABLED I60C00 DEC 15, 2020 11:17 AM TANK STICK HEIGHT OFFSET TANK PRODUCT LABEL INCHES 1 UNLEADED 87 0.00 2 SUPREME 91 0.00 3 DIESEL 0.00 4 0.00 I61200 DEC 15, 2020 11:17 AM TANK MANIFOLDED PARTNERS TANK PRODUCT LABEL SIPHON MANIFOLDED TANKS LINE MANIFOLDED TANKS 1 UNLEADED 87 NONE NONE 2 SUPREME 91 NONE NONE 3 DIESEL NONE NONE 4 NONE NONE I63600 DEC 15, 2020 11:17 AM PERIODIC LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 UNLEADED 87 120 2 SUPREME 91 120 3 DIESEL 120 4 0 I62A00 DEC 15, 2020 11:17 AM ANNUAL LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 UNLEADED 87 120 2 SUPREME 91 120 3 DIESEL 120 4 0 I62C00 DEC 15, 2020 11:17 AM TANK PERIODIC TEST TYPE TANK PRODUCT LABEL PERIODIC TEST TYPE 1 UNLEADED 87 STANDARD 2 SUPREME 91 STANDARD 3 DIESEL STANDARD 4 STANDARD I62D00 DEC 15, 2020 11:18 AM TANK LEAK TEST FAIL ALARMS TANK PRODUCT LABEL 1 UNLEADED 87 GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 2 SUPREME 91 GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 3 DIESEL GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 4 GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED I63100 DEC 15, 2020 11:18 AM TANK LEAK TEST AVERAGING TANK PRODUCT LABEL ANNUAL PERIODIC 1 UNLEADED 87 OFF OFF 2 SUPREME 91 OFF OFF 3 DIESEL OFF OFF 4 OFF OFF I63000 DEC 15, 2020 11:18 AM IN-TANK LEAK TEST NOTIFY TANK PRODUCT LABEL TANK TEST NOTIFY: 1 UNLEADED 87 OFF 2 SUPREME 91 OFF 3 DIESEL OFF 4 OFF I63200 DEC 15, 2020 11:18 AM TANK TEST SIPHON BREAK TANK PRODUCT LABEL SIPHON BREAK 1 UNLEADED 87 OFF 2 SUPREME 91 OFF 3 DIESEL OFF 4 OFF I61000 DEC 15, 2020 11:18 AM TANK DELIVERY DELAY TANK PRODUCT LABEL 1 UNLEADED 87 1 2 SUPREME 91 1 3 DIESEL 1 4 1 I63A00 DEC 15, 2020 11:18 AM LOW LEVEL PUMP THRESHOLD FOR SEQUENTIAL LINE MANIFOLD TANK PRODUCT LABEL PUMP THRESHOLD 1 UNLEADED 87 10.00% 2 SUPREME 91 10.00% 3 DIESEL 10.00% 4 10.00% I61100 DEC 15, 2020 11:18 AM LEAK TEST METHOD - - - - - - - - - - - - TEST ON DATE : ALL TANK JUL 23, 2010 START TIME : DISABLED TEST RATE :0.20 GAL/HR DURATION : 2 HOURS TST EARLY STOP:DISABLED I61300 DEC 15, 2020 11:18 AM CSLD PROBABLITY OF DETECTION I61400 DEC 15, 2020 11:18 AM CSLD CLIMATE FACTOR I61600 DEC 15, 2020 11:18 AM TANK PRODUCT LABEL CAL UPDATE 1 UNLEADED 87 IMMEDIATE 2 SUPREME 91 IMMEDIATE 3 DIESEL IMMEDIATE 4 IMMEDIATE I61A00 DEC 15, 2020 11:18 AM IN-TANK LEAK TEST EARLY STOP TANK PRODUCT LABEL TST EARLY STOP: 1 UNLEADED 87 DISABLED 2 SUPREME 91 DISABLED 3 DIESEL DISABLED 4 DISABLED I61B00 DEC 15, 2020 11:18 AM IN-TANK LEAK GROSS TEST AUTO-CONFIRM I61C00 DEC 15, 2020 11:18 AM CSLD REPORT ONLY I62B00 DEC 15, 2020 11:18 AM TANK LAST ANNUAL TEST TANK PRODUCT LABEL DATE 1 UNLEADED 87 ??? 0, 0 2 SUPREME 91 ??? 0, 0 3 DIESEL ??? 0, 0 4 ??? 0, 0 I63300 DEC 15, 2020 11:18 AM LEAK TEST REPORT FORMAT: NORMAL I63400 DEC 15, 2020 11:18 AM RECONCILIATION WARNING LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 87 0 2 SUPREME 91 0 3 DIESEL 0 4 0 I63500 DEC 15, 2020 11:18 AM RECONCILIATION ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 87 1 2 SUPREME 91 1 3 DIESEL 1 4 1 I63900 DEC 15, 2020 11:18 AM ACCU CHART END SHAPE FACTOR TANK PRODUCT LABEL 1 UNLEADED 87 END FACTOR: NONE 2 SUPREME 91 END FACTOR: NONE 3 DIESEL END FACTOR: NONE 4 END FACTOR: NONE I78000 DEC 15, 2020 11:18 AM I77700 DEC 15, 2020 11:18 AM I77800 DEC 15, 2020 11:18 AM I78C00 DEC 15, 2020 11:18 AM I78300 DEC 15, 2020 11:18 AM I78F00 DEC 15, 2020 11:18 AM I78700 DEC 15, 2020 11:18 AM I70200 DEC 15, 2020 11:18 AM LIQUID LABEL DEVICE LABEL 1 DISP. 1-2 2 DISP. 3-4 3 DISP. 11-12 4 DISP. 7-8 5 DISP. 9-10 6 DISP 5-6 7 DISP. 13-14 8 DISP. 15-16 9 UNLEADED SUMP 10 SUPREME SUMP 11 DIESEL SUMP 12 UNLEADED ANNULAR 13 SUPREME ANNULAR 14 DIESEL ANNULAR 15 UNLEADED ANN 16 17 UNL ANNULAR 18 19 UNL ANNULAR 20 21 22 23 24 BUBBA SENSOR I70300 DEC 15, 2020 11:18 AM LIQUID TYPE SENSOR LOCATION TYPE 1 DISP. 1-2 TRI-STATE (SINGLE FLOAT) 2 DISP. 3-4 TRI-STATE (SINGLE FLOAT) 3 DISP. 11-12 TRI-STATE (SINGLE FLOAT) 4 DISP. 7-8 TRI-STATE (SINGLE FLOAT) 5 DISP. 9-10 TRI-STATE (SINGLE FLOAT) 6 DISP 5-6 TRI-STATE (SINGLE FLOAT) 7 DISP. 13-14 TRI-STATE (SINGLE FLOAT) 8 DISP. 15-16 TRI-STATE (SINGLE FLOAT) 9 UNLEADED SUMP TRI-STATE (SINGLE FLOAT) 10 SUPREME SUMP TRI-STATE (SINGLE FLOAT) 11 DIESEL SUMP TRI-STATE (SINGLE FLOAT) 12 UNLEADED ANNULAR NORMALLY CLOSED 13 SUPREME ANNULAR NORMALLY CLOSED 14 DIESEL ANNULAR NORMALLY CLOSED 15 UNLEADED ANN NORMALLY CLOSED 16 TRI-STATE (SINGLE FLOAT) 17 UNL ANNULAR NORMALLY CLOSED 18 TRI-STATE (SINGLE FLOAT) 19 UNL ANNULAR NORMALLY CLOSED 20 TRI-STATE (SINGLE FLOAT) 21 TRI-STATE (SINGLE FLOAT) 22 TRI-STATE (SINGLE FLOAT) 23 TRI-STATE (SINGLE FLOAT) 24 BUBBA SENSOR NORMALLY CLOSED I70400 DEC 15, 2020 11:18 AM LIQUID CATEGORY SENSOR LOCATION CATEGORY 1 DISP. 1-2 DISPENSER PAN 2 DISP. 3-4 DISPENSER PAN 3 DISP. 11-12 DISPENSER PAN 4 DISP. 7-8 DISPENSER PAN 5 DISP. 9-10 DISPENSER PAN 6 DISP 5-6 DISPENSER PAN 7 DISP. 13-14 DISPENSER PAN 8 DISP. 15-16 DISPENSER PAN 9 UNLEADED SUMP STP SUMP 10 SUPREME SUMP STP SUMP 11 DIESEL SUMP STP SUMP 12 UNLEADED ANNULAR ANNULAR SPACE 13 SUPREME ANNULAR ANNULAR SPACE 14 DIESEL ANNULAR ANNULAR SPACE 15 UNLEADED ANN ANNULAR SPACE 16 OTHER SENSORS 17 UNL ANNULAR ANNULAR SPACE 18 OTHER SENSORS 19 UNL ANNULAR ANNULAR SPACE 20 OTHER SENSORS 21 OTHER SENSORS 22 OTHER SENSORS 23 OTHER SENSORS 24 BUBBA SENSOR OTHER SENSORS I74200 DEC 15, 2020 11:18 AM I74300 DEC 15, 2020 11:18 AM I74400 DEC 15, 2020 11:18 AM I74700 DEC 15, 2020 11:18 AM I74800 DEC 15, 2020 11:18 AM I74900 DEC 15, 2020 11:18 AM I7BC00 DEC 15, 2020 11:18 AM I80200 DEC 15, 2020 11:18 AM I80300 DEC 15, 2020 11:18 AM I80400 DEC 15, 2020 11:18 AM I80700 DEC 15, 2020 11:18 AM RELAY LABEL DEVICE LABEL 1 UNLEADED 87 2 SUPREME 3 DIESEL 4 OVERFILL ALARM 5 REMOTE ALARMS 6 REMOTE ALARM 7 8 I80900 DEC 15, 2020 11:18 AM RELAY ORIENTATION RELAY DESIGNATION ORIENTATION 1 UNLEADED 87 NORMALLY CLOSED 2 SUPREME NORMALLY CLOSED 3 DIESEL NORMALLY CLOSED 4 OVERFILL ALARM NORMALLY OPEN 5 REMOTE ALARMS NORMALLY CLOSED 6 REMOTE ALARM NORMALLY CLOSED 7 NORMALLY OPEN 8 NORMALLY OPEN I80B00 DEC 15, 2020 11:18 AM RELAY TANK ASSIGNMENT RELAY DESIGNATION TANK 1 UNLEADED 87 1 2 SUPREME 2 3 DIESEL 3 4 OVERFILL ALARM NONE 5 REMOTE ALARMS NONE 6 REMOTE ALARM NONE 7 NONE 8 NONE I80A00 DEC 15, 2020 11:18 AM RELAY TYPE RELAY DESIGNATION TYPE 1 UNLEADED 87 STANDARD 2 SUPREME STANDARD 3 DIESEL STANDARD 4 OVERFILL ALARM STANDARD 5 REMOTE ALARMS STANDARD 6 REMOTE ALARM STANDARD 7 STANDARD 8 STANDARD I80C00 DEC 15, 2020 11:18 AM I80800 DEC 15, 2020 11:18 AM RELAY SETUP REPORT R 1:UNLEADED 87 TYPE: STANDARD NORMALLY CLOSED TANK #: 1 IN-TANK ALARMS T 1:LEAK ALARM LIQUID SENSOR ALMS L 1:FUEL ALARM L 2:FUEL ALARM L 3:FUEL ALARM L 4:FUEL ALARM L 5:FUEL ALARM L 6:FUEL ALARM L 7:FUEL ALARM L 8:FUEL ALARM L 9:FUEL ALARM L 1:SENSOR OUT ALARM L 2:SENSOR OUT ALARM L 3:SENSOR OUT ALARM L 4:SENSOR OUT ALARM L 5:SENSOR OUT ALARM L 6:SENSOR OUT ALARM L 7:SENSOR OUT ALARM L 8:SENSOR OUT ALARM L 9:SENSOR OUT ALARM L 1:SHORT ALARM L 2:SHORT ALARM L 3:SHORT ALARM L 4:SHORT ALARM L 5:SHORT ALARM L 6:SHORT ALARM L 7:SHORT ALARM L 8:SHORT ALARM L 9:SHORT ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD VP PRES FAIL ISD VP STATUS FAIL ISD HOSE ALARMS ALL:GROSS COLLECT FAIL ALL:DEGRD COLLECT FAIL ALL:FLOW COLLECT FAIL R 2:SUPREME TYPE: STANDARD NORMALLY CLOSED TANK #: 2 IN-TANK ALARMS T 2:LEAK ALARM T 2:LOW PRODUCT ALARM LIQUID SENSOR ALMS L 1:FUEL ALARM L 2:FUEL ALARM L 3:FUEL ALARM L 4:FUEL ALARM L 5:FUEL ALARM L 6:FUEL ALARM L 7:FUEL ALARM L 8:FUEL ALARM L10:FUEL ALARM L 1:SENSOR OUT ALARM L 2:SENSOR OUT ALARM L 3:SENSOR OUT ALARM L 4:SENSOR OUT ALARM L 5:SENSOR OUT ALARM L 6:SENSOR OUT ALARM L 7:SENSOR OUT ALARM L 8:SENSOR OUT ALARM L10:SENSOR OUT ALARM L 1:SHORT ALARM L 2:SHORT ALARM L 3:SHORT ALARM L 4:SHORT ALARM L 5:SHORT ALARM L 6:SHORT ALARM L 7:SHORT ALARM L 8:SHORT ALARM L10:SHORT ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD VP PRES FAIL ISD VP STATUS FAIL ISD HOSE ALARMS ALL:GROSS COLLECT FAIL ALL:DEGRD COLLECT FAIL ALL:FLOW COLLECT FAIL R 3:DIESEL TYPE: STANDARD NORMALLY CLOSED TANK #: 3 IN-TANK ALARMS T 3:LEAK ALARM T 3:LOW PRODUCT ALARM LIQUID SENSOR ALMS L 1:FUEL ALARM L 4:FUEL ALARM L 5:FUEL ALARM L 8:FUEL ALARM L11:FUEL ALARM L 1:SENSOR OUT ALARM L 4:SENSOR OUT ALARM L 5:SENSOR OUT ALARM L 8:SENSOR OUT ALARM L11:SENSOR OUT ALARM L 1:SHORT ALARM L 4:SHORT ALARM L 5:SHORT ALARM L 8:SHORT ALARM L11:SHORT ALARM R 4:OVERFILL ALARM TYPE: STANDARD NORMALLY OPEN TANK #: NONE IN-TANK ALARMS ALL:OVERFILL ALARM ALL:HIGH PRODUCT ALARM ALL:MAX PRODUCT ALARM R 5:REMOTE ALARMS TYPE: STANDARD NORMALLY CLOSED TANK #: NONE IN-TANK ALARMS ALL:LEAK ALARM ALL:HIGH WATER ALARM ALL:OVERFILL ALARM ALL:LOW PRODUCT ALARM ALL:SUDDEN LOSS ALARM ALL:HIGH PRODUCT ALARM ALL:INVALID FUEL LEVEL ALL:PROBE OUT ALL:HIGH WATER WARNING ALL:DELIVERY NEEDED ALL:MAX PRODUCT ALARM ALL:GROSS TEST FAIL ALL:PERIODIC TEST FAIL ALL:ANNUAL TEST FAIL ALL:PER TST NEEDED WRN LIQUID SENSOR ALMS L 1:FUEL ALARM L 2:FUEL ALARM L 3:FUEL ALARM L 4:FUEL ALARM L 5:FUEL ALARM L 6:FUEL ALARM L 7:FUEL ALARM L 8:FUEL ALARM L 9:FUEL ALARM L10:FUEL ALARM L11:FUEL ALARM L12:FUEL ALARM L13:FUEL ALARM L14:FUEL ALARM L15:FUEL ALARM L16:FUEL ALARM L 1:SENSOR OUT ALARM L 2:SENSOR OUT ALARM L 3:SENSOR OUT ALARM L 4:SENSOR OUT ALARM L 5:SENSOR OUT ALARM L 6:SENSOR OUT ALARM L 7:SENSOR OUT ALARM L 8:SENSOR OUT ALARM L 9:SENSOR OUT ALARM L10:SENSOR OUT ALARM L11:SENSOR OUT ALARM L12:SENSOR OUT ALARM L13:SENSOR OUT ALARM L14:SENSOR OUT ALARM L15:SENSOR OUT ALARM L16:SENSOR OUT ALARM L 1:SHORT ALARM L 2:SHORT ALARM L 3:SHORT ALARM L 4:SHORT ALARM L 5:SHORT ALARM L 6:SHORT ALARM L 7:SHORT ALARM L 8:SHORT ALARM L 9:SHORT ALARM L10:SHORT ALARM L11:SHORT ALARM L12:SHORT ALARM L13:SHORT ALARM L14:SHORT ALARM L15:SHORT ALARM L16:SHORT ALARM SMARTSENSOR ALARMS ALL:SETUP DATA WARNING ALL:COMMUNICATION ALARM ALL:SENSOR FAULT ALARM ALL:SENSOR FAULT WARN ISD SITE ALARMS ISD STAGE I WARN ISD GROSS PRES WARN ISD GROSS PRES FAIL ISD DEGRD PRES WARN ISD DEGRD PRES FAIL ISD VAPOR LEAK WARN ISD VAPOR LEAK FAIL ISD VP PRES WARN ISD VP PRES FAIL ISD VP STATUS WARN ISD VP STATUS FAIL MISSING RELAY SETUP MISSING HOSE SETUP MISSING TANK SETUP MISS VAPOR FLOW MTR MISS VAPOR PRES SEN MISSING VP INPUT ISD SETUP WARN ISD SETUP FAIL ISD SENSOR OUT WARN ISD SENSOR OUT FAIL ISD HOSE ALARMS ALL:GROSS COLLECT WARN ALL:GROSS COLLECT FAIL ALL:DEGRD COLLECT WARN ALL:DEGRD COLLECT FAIL ALL:FLOW COLLECT WARN ALL:FLOW COLLECT FAIL ALL:AIRFLOW MTR SETUP VAPOR FLW MTR ALMS ALL:CHK VAPOR FLOW MTR R 6:REMOTE ALARM TYPE: STANDARD NORMALLY CLOSED TANK #: NONE IN-TANK ALARMS ALL:OVERFILL ALARM ALL:HIGH PRODUCT ALARM ALL:MAX PRODUCT ALARM LIQUID SENSOR ALMS L 1:FUEL ALARM L 2:FUEL ALARM L 3:FUEL ALARM L 4:FUEL ALARM L 5:FUEL ALARM L 6:FUEL ALARM L 7:FUEL ALARM L 8:FUEL ALARM L 9:FUEL ALARM L10:FUEL ALARM L11:FUEL ALARM L12:FUEL ALARM L13:FUEL ALARM L14:FUEL ALARM L15:FUEL ALARM L16:FUEL ALARM L 1:SENSOR OUT ALARM L 2:SENSOR OUT ALARM L 3:SENSOR OUT ALARM L 4:SENSOR OUT ALARM L 5:SENSOR OUT ALARM L 6:SENSOR OUT ALARM L 7:SENSOR OUT ALARM L 8:SENSOR OUT ALARM L 9:SENSOR OUT ALARM L10:SENSOR OUT ALARM L11:SENSOR OUT ALARM L12:SENSOR OUT ALARM L13:SENSOR OUT ALARM L14:SENSOR OUT ALARM L15:SENSOR OUT ALARM L16:SENSOR OUT ALARM L 1:SHORT ALARM L 2:SHORT ALARM L 3:SHORT ALARM L 4:SHORT ALARM L 5:SHORT ALARM L 6:SHORT ALARM L 7:SHORT ALARM L 8:SHORT ALARM L 9:SHORT ALARM L10:SHORT ALARM L11:SHORT ALARM L12:SHORT ALARM L13:SHORT ALARM L14:SHORT ALARM L15:SHORT ALARM L16:SHORT ALARM SMARTSENSOR ALARMS ALL:COMMUNICATION ALARM ISD SITE ALARMS ISD STAGE I WARN ISD GROSS PRES WARN ISD GROSS PRES FAIL ISD DEGRD PRES WARN ISD DEGRD PRES FAIL ISD VAPOR LEAK WARN ISD VAPOR LEAK FAIL ISD VP PRES WARN ISD VP PRES FAIL ISD VP STATUS WARN ISD VP STATUS FAIL MISSING RELAY SETUP MISSING HOSE SETUP ISD SENSOR OUT WARN ISD SENSOR OUT FAIL ISD HOSE ALARMS ALL:GROSS COLLECT WARN ALL:GROSS COLLECT FAIL ALL:DEGRD COLLECT WARN ALL:DEGRD COLLECT FAIL ALL:FLOW COLLECT WARN ALL:FLOW COLLECT FAIL ALL:AIRFLOW MTR SETUP VAPOR FLW MTR ALMS ALL:CHK VAPOR FLOW MTR R 7: TYPE: STANDARD NORMALLY OPEN TANK #: NONE - NO ALARM ASSIGNMENTS - R 8: TYPE: STANDARD NORMALLY OPEN TANK #: NONE - NO ALARM ASSIGNMENTS - I79000 DEC 15, 2020 11:19 AM EDIM:1 VR:349643-001-B TD:97.10.27.11.25 I79100 DEC 15, 2020 11:19 AM I72300 DEC 15, 2020 11:19 AM 286917 SPARKLING IMA 2301 H ST. BAKERSFIELD,CA 93301 661-324-8455 SMARTSENSOR ASSIGNMENT DEVICE LABEL CATEGORY 01 FM 1-2 AIR FLOW METER 02 FM 3-4 AIR FLOW METER 03 FM 5-6 AIR FLOW METER 04 FM 7-8 AIR FLOW METER 05 FM 9-10 AIR FLOW METER 06 FM 11-12 AIR FLOW METER 07 FM 13-14 AIR FLOW METER 08 PRESSURE SENSOR VAPOR PRESSURE 09 FM 15-16 AIR FLOW METER 10 UNKNOWN 11 UNKNOWN 12 UNKNOWN 13 UNKNOWN 14 UNKNOWN 15 UNKNOWN 16 UNKNOWN 17 UNKNOWN 18 UNKNOWN 19 UNKNOWN 20 UNKNOWN 21 UNKNOWN 22 UNKNOWN 23 UNKNOWN 24 UNKNOWN 25 UNKNOWN 26 UNKNOWN 27 UNKNOWN 28 UNKNOWN 29 UNKNOWN 30 UNKNOWN 31 UNKNOWN 32 UNKNOWN 33 UNKNOWN 34 UNKNOWN 35 UNKNOWN 36 UNKNOWN 37 UNKNOWN 38 UNKNOWN 39 UNKNOWN 40 UNKNOWN IV4E00 DEC 15, 2020 11:19 AM 286917 SPARKLING IMA 2301 H ST. BAKERSFIELD,CA 93301 661-324-8455 EVR/ISD SETUP TYPE: VACUUM ASSIST VACUUM ASSIST TYPE: HEALY VAC IV4F00 DEC 15, 2020 11:19 AM 286917 SPARKLING IMA 2301 H ST. BAKERSFIELD,CA 93301 661-324-8455 NOZZLE A/L RANGE A/L RATIO: 0.95 - 1.15 IV4000 DEC 15, 2020 11:19 AM 286917 SPARKLING IMA 2301 H ST. BAKERSFIELD,CA 93301 661-324-8455 VAPOR PROCESSOR TYPE NONE IV4700 DEC 15, 2020 11:19 AM 286917 SPARKLING IMA 2301 H ST. BAKERSFIELD,CA 93301 661-324-8455 ASSESSMENT TIME START TIME: 9:22 AM TIME DELAY MINUTES: 1 IV5200 DEC 15, 2020 11:19 AM 286917 SPARKLING IMA 2301 H ST. BAKERSFIELD,CA 93301 661-324-8455 ACCEPT HIGH ORVR: NO IV4A00 DEC 15, 2020 11:19 AM 286917 SPARKLING IMA 2301 H ST. BAKERSFIELD,CA 93301 661-324-8455 ISD HOSE TABLE HOSE FP FP AFM REL HOSE ID ID LABEL ID ID LABEL 01 01 01 01 06 BLEND3 02 02 02 01 06 BLEND3 03 03 03 02 06 BLEND3 04 04 04 02 06 BLEND3 05 05 05 03 06 BLEND3 06 06 06 03 06 BLEND3 07 07 07 04 06 BLEND3 08 08 08 04 06 BLEND3 09 09 09 05 06 BLEND3 10 16 10 05 06 BLEND3 11 17 11 06 06 BLEND3 12 18 12 06 06 BLEND3 13 19 13 07 06 BLEND3 14 20 14 07 06 BLEND3 15 21 15 08 06 BLEND3 16 22 16 08 06 BLEND3 IV4B00 DEC 15, 2020 11:19 AM 286917 SPARKLING IMA 2301 H ST. BAKERSFIELD,CA 93301 661-324-8455 PRODUCT/HOSE MAP TABLE FP AFID M1/H1 M2/H2 M3/H3 M4/H4 01 01 01/01 02/01 09/01 xx/xx 02 01 01/02 09/02 02/02 xx/xx 03 02 01/03 09/03 02/03 xx/xx 04 02 01/04 09/04 02/04 xx/xx 05 03 01/05 09/05 02/05 xx/xx 06 03 01/06 09/06 02/06 xx/xx 07 04 01/07 09/07 02/07 xx/xx 08 04 01/08 09/08 02/08 xx/xx 09 05 01/09 09/09 02/09 xx/xx 16 05 01/10 09/10 02/10 xx/xx 17 06 01/11 09/11 02/11 xx/xx 18 06 01/12 09/12 02/12 xx/xx 19 07 01/13 09/13 02/13 xx/xx 20 07 01/14 09/14 02/14 xx/xx 21 08 01/15 09/15 02/15 xx/xx 22 08 01/16 09/16 02/16 xx/xx IV4900 DEC 15, 2020 11:19 AM 286917 SPARKLING IMA 2301 H ST. BAKERSFIELD,CA 93301 661-324-8455 LABEL TABLE ID LABEL 01 UNASSIGNED 02 BLEND3 03 REGULAR 04 MID GRADE 05 PREMIUM 06 GOLD 07 BRONZE 08 SILVER 09 BLEND2 10 BLEND4 IV1000 DEC 15, 2020 11:19 AM ISD VERSION: 01.06 ALARM HISTORY BEFORE Responses Received: I10200 DEC 15, 2020 11:20 AM 286917 SPARKLING IMA 2301 H ST. BAKERSFIELD,CA 93301 661-324-8455 SYSTEM CONFIGURATION SLOT BOARD TYPE POWER ON RESET CURRENT 1 UNUSED 9852359 9658263 2 4 PROBE / G.T. 163465 163195 3 8SMARTSENSOR BD 39589 39530 4 7SMARTSENSOR BD 507789 506868 5 INTERSTITIAL BD 201480 201293 6 INTERSTITIAL BD 202096 201759 7 INTERSTITIAL BD 200750 200455 8 UNUSED 9828973 9653350 9 RELAY BOARD 15000 14992 10 RELAY BOARD 14934 14969 11 UNUSED 9834834 9644769 12 UNUSED 9823885 9637087 13 UNUSED 9823820 9645283 14 UNUSED 9810856 9636260 15 UNUSED 9818236 9643876 16 UNUSED 9817272 9633603 COMM 1 ELEC DISP INT. 100586 100510 COMM 2 RS232 SERIAL BD 14934 14969 COMM 3 SERIAL SAT BD 480450 479587 COMM 4 UNUSED 9832382 9647382 COMM 5 UNUSED 9816090 9633134 COMM 6 UNUSED 9816856 9635814 I90200 DEC 15, 2020 11:20 AM SOFTWARE REVISION LEVEL VERSION 336.00 SOFTWARE# 346336-100-A CREATED - 19.12.13.15.19 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS CSLD BIR FUEL MANAGER ISD/APM PLLD 0.10 AUTO 0.20 REPETITIV WPLLD 0.10 AUTO 0.20 REPETITIV I11100 DEC 15, 2020 11:20 AM 286917 SPARKLING IMA 2301 H ST. BAKERSFIELD,CA 93301 661-324-8455 PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME T 1 TANK UNLEADED 87 PROBE OUT CLEAR 12-15-20 11:11AM T 1 TANK UNLEADED 87 PROBE OUT ALARM 12-15-20 11:10AM T 1 TANK UNLEADED 87 PROBE OUT CLEAR 12-15-20 11:10AM T 1 TANK UNLEADED 87 PROBE OUT ALARM 12-15-20 11:08AM T 1 TANK UNLEADED 87 PROBE OUT CLEAR 12-15-20 11:08AM T 1 TANK UNLEADED 87 PROBE OUT ALARM 12-15-20 11:02AM T 1 TANK UNLEADED 87 PROBE OUT CLEAR 12-15-20 10:54AM T 1 TANK UNLEADED 87 PROBE OUT ALARM 12-15-20 10:53AM L 9 STP SUMP UNLEADED SUMP FUEL ALARM CLEAR 12-15-20 10:53AM L 9 STP SUMP UNLEADED SUMP FUEL ALARM ALARM 12-15-20 10:53AM E 1 OTHER COMMUNICATION ALARM CLEAR 12-14-20 2:05AM E 1 OTHER COMMUNICATION ALARM ALARM 12-14-20 2:03AM E 1 OTHER COMMUNICATION ALARM CLEAR 12-07-20 2:06AM E 1 OTHER COMMUNICATION ALARM ALARM 12-07-20 2:03AM E 1 OTHER COMMUNICATION ALARM CLEAR 11-30-20 2:05AM E 1 OTHER COMMUNICATION ALARM ALARM 11-30-20 2:03AM OTHER ISD GROSS PRES FAIL CLEAR 11-26-20 9:53AM OTHER ISD GROSS PRES FAIL ALARM 11-26-20 9:26AM E 1 OTHER COMMUNICATION ALARM CLEAR 11-23-20 2:06AM E 1 OTHER COMMUNICATION ALARM ALARM 11-23-20 2:04AM E 1 OTHER COMMUNICATION ALARM CLEAR 11-16-20 2:05AM E 1 OTHER COMMUNICATION ALARM ALARM 11-16-20 2:03AM OTHER ISD GROSS PRES FAIL CLEAR 11-12-20 9:57AM OTHER ISD GROSS PRES FAIL ALARM 11-12-20 9:24AM E 1 OTHER COMMUNICATION ALARM CLEAR 11-09-20 2:05AM E 1 OTHER COMMUNICATION ALARM ALARM 11-09-20 2:02AM E 1 OTHER COMMUNICATION ALARM CLEAR 11-07-20 8:28PM E 1 OTHER COMMUNICATION ALARM ALARM 11-07-20 8:26PM E 1 OTHER COMMUNICATION ALARM CLEAR 11-07-20 8:26PM E 1 OTHER COMMUNICATION ALARM ALARM 11-07-20 7:01AM E 1 OTHER COMMUNICATION ALARM CLEAR 11-06-20 8:36AM E 1 OTHER COMMUNICATION ALARM ALARM 11-06-20 8:33AM T 1 TANK UNLEADED 87 OVERFILL ALARM CLEAR 11-02-20 2:40AM T 1 TANK UNLEADED 87 OVERFILL ALARM ALARM 11-02-20 2:36AM E 1 OTHER COMMUNICATION ALARM CLEAR 11-02-20 2:05AM E 1 OTHER COMMUNICATION ALARM ALARM 11-02-20 2:03AM E 1 OTHER COMMUNICATION ALARM CLEAR 10-26-20 2:05AM E 1 OTHER COMMUNICATION ALARM ALARM 10-26-20 2:03AM E 1 OTHER COMMUNICATION ALARM CLEAR 10-19-20 2:06AM E 1 OTHER COMMUNICATION ALARM ALARM 10-19-20 2:03AM E 1 OTHER COMMUNICATION ALARM CLEAR 10-12-20 2:05AM E 1 OTHER COMMUNICATION ALARM ALARM 10-12-20 2:03AM L12 ANNULAR UNLEADED ANNULAR FUEL ALARM ALARM 10-11-20 3:35AM L12 ANNULAR UNLEADED ANNULAR FUEL ALARM CLEAR 10-09-20 11:37AM L12 ANNULAR UNLEADED ANNULAR FUEL ALARM ALARM 10-09-20 11:14AM L12 ANNULAR UNLEADED ANNULAR FUEL ALARM CLEAR 10-09-20 10:39AM L12 ANNULAR UNLEADED ANNULAR FUEL ALARM ALARM 10-09-20 10:38AM L12 ANNULAR UNLEADED ANNULAR FUEL ALARM CLEAR 10-09-20 10:38AM E 1 OTHER COMMUNICATION ALARM CLEAR 10-05-20 2:06AM E 1 OTHER COMMUNICATION ALARM ALARM 10-05-20 2:03AM I11200 DEC 15, 2020 11:20 AM 286917 SPARKLING IMA 2301 H ST. BAKERSFIELD,CA 93301 661-324-8455 NON-PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME OTHER ISD GROSS PRES WARN CLEAR 12-15-20 11:18AM OTHER ISD GROSS PRES WARN ALARM 12-15-20 9:25AM SYSTEM PRINTER ERROR CLEAR 12-15-20 8:55AM SYSTEM PAPER OUT CLEAR 12-15-20 8:55AM SYSTEM PRINTER ERROR ALARM 12-15-20 8:54AM SYSTEM PAPER OUT ALARM 12-15-20 8:54AM OTHER ISD GROSS PRES WARN CLEAR 12-08-20 10:53AM OTHER ISD GROSS PRES WARN ALARM 12-03-20 9:25AM SYSTEM PRINTER ERROR CLEAR 11-30-20 4:28PM SYSTEM PAPER OUT CLEAR 11-30-20 4:28PM SYSTEM PRINTER ERROR ALARM 11-30-20 4:28PM SYSTEM PAPER OUT ALARM 11-30-20 4:28PM SYSTEM PRINTER ERROR CLEAR 11-30-20 4:28PM SYSTEM PAPER OUT CLEAR 11-30-20 4:28PM SYSTEM PRINTER ERROR ALARM 11-30-20 4:24PM SYSTEM PAPER OUT ALARM 11-30-20 4:24PM OTHER ISD GROSS PRES WARN CLEAR 11-26-20 9:22AM OTHER ISD GROSS PRES WARN ALARM 11-19-20 9:24AM OTHER ISD GROSS PRES WARN CLEAR 11-12-20 9:22AM SYSTEM PRINTER ERROR CLEAR 11-09-20 10:43AM SYSTEM PAPER OUT CLEAR 11-09-20 10:43AM SYSTEM PAPER OUT ALARM 11-09-20 10:41AM SYSTEM PRINTER ERROR ALARM 11-09-20 10:41AM OTHER ISD SENSOR OUT WARN CLEAR 11-08-20 9:24AM OTHER ISD SENSOR OUT WARN ALARM 11-07-20 9:24AM OTHER ISD GROSS PRES WARN ALARM 11-05-20 9:27AM SYSTEM PRINTER ERROR CLEAR 10-22-20 8:00AM SYSTEM PAPER OUT CLEAR 10-22-20 8:00AM SYSTEM PAPER OUT ALARM 10-22-20 7:58AM SYSTEM PRINTER ERROR ALARM 10-22-20 7:58AM SYSTEM PRINTER ERROR CLEAR 10-22-20 7:57AM SYSTEM PAPER OUT CLEAR 10-22-20 7:57AM SYSTEM PRINTER ERROR ALARM 10-18-20 7:35AM SYSTEM PAPER OUT ALARM 10-18-20 7:35AM SYSTEM PRINTER ERROR CLEAR 10-03-20 8:05PM SYSTEM PAPER OUT CLEAR 10-03-20 8:05PM SYSTEM PAPER OUT ALARM 10-03-20 8:04PM SYSTEM PRINTER ERROR ALARM 10-03-20 8:04PM SYSTEM PRINTER ERROR CLEAR 10-03-20 8:01PM SYSTEM PAPER OUT CLEAR 10-03-20 8:01PM SYSTEM PAPER OUT ALARM 10-03-20 8:00PM SYSTEM PRINTER ERROR ALARM 10-03-20 8:00PM SYSTEM PRINTER ERROR CLEAR 10-03-20 8:00PM SYSTEM PAPER OUT CLEAR 10-03-20 8:00PM SYSTEM PAPER OUT ALARM 10-03-20 8:00PM SYSTEM PRINTER ERROR ALARM 10-03-20 8:00PM SYSTEM PRINTER ERROR CLEAR 10-03-20 8:00PM SYSTEM PRINTER ERROR ALARM 10-03-20 7:59PM SYSTEM PRINTER ERROR CLEAR 10-03-20 7:59PM SYSTEM PRINTER ERROR ALARM 10-03-20 7:59PM I20600 DEC 15, 2020 11:20 AM 286917 SPARKLING IMA 2301 H ST. BAKERSFIELD,CA 93301 661-324-8455 TANK ALARM HISTORY TANK 1 UNLEADED 87 OVERFILL ALARM NOV 2, 2020 2:36 AM PROBE OUT DEC 15, 2020 11:10 AM DEC 15, 2020 11:08 AM DEC 15, 2020 11:02 AM TANK 2 SUPREME 91 DELIVERY NEEDED JUL 18, 2020 9:15 PM TANK 3 DIESEL TANK 5 TANK 6 TANK 7 TANK 8 TANK 9 TANK 10 TANK 11 TANK 12 TANK 13 TANK 14 TANK 15 TANK 16 I38200 DEC 15, 2020 11:21 AM I30200 DEC 15, 2020 11:21 AM 286917 SPARKLING IMA 2301 H ST. BAKERSFIELD,CA 93301 661-324-8455 LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 DISP. 1-2 JUN 18, 2020 8:40 AM SENSOR OUT ALARM JUN 18, 2020 8:24 AM FUEL ALARM 2 DISP. 3-4 JUN 18, 2020 8:40 AM SENSOR OUT ALARM JUN 18, 2020 8:23 AM FUEL ALARM 3 DISP. 11-12 JUN 18, 2020 8:40 AM SENSOR OUT ALARM JUN 18, 2020 8:21 AM FUEL ALARM 4 DISP. 7-8 JUN 18, 2020 8:40 AM SENSOR OUT ALARM JUN 18, 2020 8:22 AM FUEL ALARM 5 DISP. 9-10 JUN 18, 2020 8:40 AM SENSOR OUT ALARM JUN 18, 2020 8:22 AM FUEL ALARM 6 DISP 5-6 JUN 18, 2020 8:40 AM SENSOR OUT ALARM JUN 18, 2020 8:23 AM FUEL ALARM 7 DISP. 13-14 JUN 18, 2020 8:40 AM SENSOR OUT ALARM JUN 18, 2020 8:20 AM FUEL ALARM 8 DISP. 15-16 JUN 18, 2020 8:40 AM SENSOR OUT ALARM JUN 18, 2020 8:19 AM FUEL ALARM MAY 29, 2020 6:44 AM FUEL ALARM 9 UNLEADED SUMP DEC 15, 2020 10:53 AM FUEL ALARM JUN 18, 2020 8:40 AM SENSOR OUT ALARM JUN 18, 2020 8:14 AM FUEL ALARM 10 SUPREME SUMP JUN 18, 2020 8:40 AM SENSOR OUT ALARM JUN 18, 2020 8:15 AM FUEL ALARM 11 DIESEL SUMP JUN 18, 2020 8:40 AM SENSOR OUT ALARM JUN 18, 2020 8:15 AM FUEL ALARM 12 UNLEADED ANNULAR OCT 11, 2020 3:35 AM FUEL ALARM OCT 9, 2020 11:14 AM FUEL ALARM OCT 9, 2020 10:38 AM FUEL ALARM 13 SUPREME ANNULAR JUN 18, 2020 8:32 AM FUEL ALARM 14 DIESEL ANNULAR JUN 18, 2020 8:40 AM FUEL ALARM JUN 18, 2020 8:27 AM FUEL ALARM I31600 DEC 15, 2020 11:21 AM 286917 SPARKLING IMA 2301 H ST. BAKERSFIELD,CA 93301 661-324-8455 SMART SENSOR ALARM HISTORY REPORT SENSOR LOCATION 1 FM 1-2 DEC 13, 2019 8:39 AM COMMUNICATION ALARM 2 FM 3-4 DEC 13, 2019 8:39 AM COMMUNICATION ALARM 3 FM 5-6 DEC 13, 2019 8:39 AM COMMUNICATION ALARM 4 FM 7-8 5 FM 9-10 DEC 13, 2019 8:39 AM COMMUNICATION ALARM 6 FM 11-12 DEC 13, 2019 8:39 AM COMMUNICATION ALARM 7 FM 13-14 DEC 13, 2019 8:39 AM COMMUNICATION ALARM 8 PRESSURE SENSOR 9 FM 15-16 I40200 DEC 15, 2020 11:21 AM I40300 DEC 15, 2020 11:21 AM I34200 DEC 15, 2020 11:21 AM I34700 DEC 15, 2020 11:21 AM IV0100 DEC 15, 2020 11:21 AM 286917 SPARKLING IMA 2301 H ST. BAKERSFIELD,CA 93301 661-324-8455 ISD ALARM STATUS REPORT EVR TYPE: VACUUM ASSIST ISD TYPE: 01.06 VAPOR PROCESSOR TYPE: NONE OVERALL STATUS :WARN EVR VAPOR COLLECTION :PASS EVR VAPOR CONTAINMENT :WARN ISD MONITOR UP-TIME :100% EVR/ISD PASS TIME : 0% WARNING ALARMS DATE TIME DESCRIPTION READING VALUE 20-12-15 09:25:25 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.50 20-12-08 09:24:50 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.52 20-12-07 09:24:58 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.52 20-12-06 09:25:11 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.50 20-12-05 09:25:31 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.52 20-12-04 09:25:51 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.52 20-12-03 09:25:46 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.52 20-11-25 09:26:13 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.46 20-11-24 09:26:14 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.51 20-11-23 09:25:22 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.52 FAILURE ALARMS DATE TIME DESCRIPTION READING VALUE 20-11-26 09:26:56 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.30 20-11-12 09:24:44 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.55 20-05-04 09:26:50 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 24.17 20-04-07 09:26:07 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 18.27 19-08-03 10:03:31 A/L RATIO GROSS BLOCKAGE FP 6 BLEND3 BLKD 19-07-03 10:03:50 SENSOR OUT SELFTEST s 9 19-07-02 10:06:28 SENSOR OUT SELFTEST s 9 19-07-01 10:05:29 SENSOR OUT SELFTEST s 9 19-06-30 10:05:10 SENSOR OUT SELFTEST s 9 19-06-29 10:02:43 SENSOR OUT SELFTEST s 9 SHUTDOWN & MISCELLANEOUS EVENTS DATE TIME DESCRIPTION ACTION/NAME 20-12-15 11:18:48 CONTAINMENT GROSS & DEGRD TEST MANUALLY CLEARED 20-12-08 10:53:09 CONTAINMENT GROSS & DEGRD TEST MANUALLY CLEARED 20-11-26 09:53:03 CONTAINMENT GROSS & DEGRD TEST MANUALLY CLEARED 20-11-26 09:26:56 CONTAINMENT GROSS DISABLED DISPENSERS 20-11-12 10:01:19 CONTAINMENT GROSS & DEGRD TEST MANUALLY CLEARED 20-11-12 09:57:30 CONTAINMENT GROSS & DEGRD TEST MANUALLY CLEARED 20-11-12 09:24:44 CONTAINMENT GROSS DISABLED DISPENSERS 20-11-01 01:00:00 TIME CHANGE DETECTED AT: 20-11-01 02:00:13 20-09-16 09:26:46 READINESS ISD:PP EVR:PP ISD & EVR READY 20-09-16 02:55:22 READINESS ISD:PP EVR:NN EVR READINESS PENDING ALARM HISTORY AFTER Responses Received: I10200 DEC 15, 2020 6:19 PM 286917 SPARKLING IMA 2301 H ST. BAKERSFIELD,CA 93301 661-324-8455 SYSTEM CONFIGURATION SLOT BOARD TYPE POWER ON RESET CURRENT 1 UNUSED 9852359 9922633 2 4 PROBE / G.T. 163465 163653 3 8SMARTSENSOR BD 39589 39584 4 7SMARTSENSOR BD 507789 507885 5 INTERSTITIAL BD 201480 201907 6 INTERSTITIAL BD 202096 202430 7 INTERSTITIAL BD 200750 201042 8 UNUSED 9828973 9911296 9 RELAY BOARD 15000 14992 10 RELAY BOARD 14934 14949 11 UNUSED 9834834 9926866 12 UNUSED 9823885 9907075 13 UNUSED 9823820 9907315 14 UNUSED 9810856 9909412 15 UNUSED 9818236 9898053 16 UNUSED 9817272 9911750 COMM 1 ELEC DISP INT. 100586 100696 COMM 2 RS232 SERIAL BD 14934 14992 COMM 3 SERIAL SAT BD 480450 481190 COMM 4 UNUSED 9832382 9913257 COMM 5 UNUSED 9816090 9912886 COMM 6 UNUSED 9816856 9902990 I90200 DEC 15, 2020 6:19 PM SOFTWARE REVISION LEVEL VERSION 336.00 SOFTWARE# 346336-100-A CREATED - 19.12.13.15.19 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS CSLD BIR FUEL MANAGER ISD/APM PLLD 0.10 AUTO 0.20 REPETITIV WPLLD 0.10 AUTO 0.20 REPETITIV I11100 DEC 15, 2020 6:19 PM 286917 SPARKLING IMA 2301 H ST. BAKERSFIELD,CA 93301 661-324-8455 PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME L12 ANNULAR UNLEADED ANNULAR FUEL ALARM CLEAR 12-15-20 5:59PM L 9 STP SUMP UNLEADED SUMP SENSOR OUT ALARM CLEAR 12-15-20 5:49PM L 9 STP SUMP UNLEADED SUMP SENSOR OUT ALARM ALARM 12-15-20 5:49PM L 9 STP SUMP UNLEADED SUMP SENSOR OUT ALARM CLEAR 12-15-20 5:49PM T 1 TANK UNLEADED 87 PROBE OUT CLEAR 12-15-20 5:48PM T 1 TANK UNLEADED 87 PROBE OUT ALARM 12-15-20 5:47PM T 1 TANK UNLEADED 87 PROBE OUT CLEAR 12-15-20 5:47PM L 9 STP SUMP UNLEADED SUMP SENSOR OUT ALARM ALARM 12-15-20 5:46PM L 9 STP SUMP UNLEADED SUMP SENSOR OUT ALARM CLEAR 12-15-20 5:46PM L 9 STP SUMP UNLEADED SUMP SENSOR OUT ALARM ALARM 12-15-20 5:46PM L 9 STP SUMP UNLEADED SUMP SENSOR OUT ALARM CLEAR 12-15-20 5:44PM L 9 STP SUMP UNLEADED SUMP SENSOR OUT ALARM ALARM 12-15-20 5:44PM L12 ANNULAR UNLEADED ANNULAR FUEL ALARM ALARM 12-15-20 5:41PM T 1 TANK UNLEADED 87 PROBE OUT ALARM 12-15-20 5:33PM L 9 STP SUMP UNLEADED SUMP SENSOR OUT ALARM CLEAR 12-15-20 5:26PM L12 ANNULAR UNLEADED ANNULAR FUEL ALARM CLEAR 12-15-20 5:22PM L12 ANNULAR UNLEADED ANNULAR FUEL ALARM ALARM 12-15-20 5:22PM L 9 STP SUMP UNLEADED SUMP SENSOR OUT ALARM ALARM 12-15-20 5:21PM L 9 STP SUMP UNLEADED SUMP FUEL ALARM CLEAR 12-15-20 5:21PM L 9 STP SUMP UNLEADED SUMP SENSOR OUT ALARM CLEAR 12-15-20 5:21PM L 9 STP SUMP UNLEADED SUMP FUEL ALARM ALARM 12-15-20 5:21PM L 9 STP SUMP UNLEADED SUMP SENSOR OUT ALARM ALARM 12-15-20 5:21PM L 9 STP SUMP UNLEADED SUMP FUEL ALARM CLEAR 12-15-20 5:21PM L 9 STP SUMP UNLEADED SUMP SENSOR OUT ALARM CLEAR 12-15-20 5:21PM L 9 STP SUMP UNLEADED SUMP FUEL ALARM ALARM 12-15-20 5:21PM T 1 TANK UNLEADED 87 PROBE OUT CLEAR 12-15-20 5:19PM L 9 STP SUMP UNLEADED SUMP SENSOR OUT ALARM ALARM 12-15-20 5:17PM L 9 STP SUMP UNLEADED SUMP FUEL ALARM CLEAR 12-15-20 5:17PM L 9 STP SUMP UNLEADED SUMP SENSOR OUT ALARM CLEAR 12-15-20 5:16PM L 9 STP SUMP UNLEADED SUMP FUEL ALARM ALARM 12-15-20 5:16PM L 9 STP SUMP UNLEADED SUMP SENSOR OUT ALARM ALARM 12-15-20 5:13PM L 9 STP SUMP UNLEADED SUMP FUEL ALARM CLEAR 12-15-20 5:13PM L 9 STP SUMP UNLEADED SUMP SENSOR OUT ALARM CLEAR 12-15-20 4:14PM L 9 STP SUMP UNLEADED SUMP FUEL ALARM ALARM 12-15-20 4:14PM L12 ANNULAR UNLEADED ANNULAR FUEL ALARM CLEAR 12-15-20 4:14PM L 9 STP SUMP UNLEADED SUMP SENSOR OUT ALARM ALARM 12-15-20 4:13PM L 9 STP SUMP UNLEADED SUMP FUEL ALARM CLEAR 12-15-20 4:13PM L 9 STP SUMP UNLEADED SUMP SENSOR OUT ALARM CLEAR 12-15-20 4:13PM L 9 STP SUMP UNLEADED SUMP FUEL ALARM ALARM 12-15-20 4:13PM L 9 STP SUMP UNLEADED SUMP SENSOR OUT ALARM ALARM 12-15-20 4:13PM L 9 STP SUMP UNLEADED SUMP FUEL ALARM CLEAR 12-15-20 4:13PM L 9 STP SUMP UNLEADED SUMP SENSOR OUT ALARM CLEAR 12-15-20 4:13PM L 9 STP SUMP UNLEADED SUMP FUEL ALARM ALARM 12-15-20 4:13PM L 9 STP SUMP UNLEADED SUMP SENSOR OUT ALARM ALARM 12-15-20 3:37PM L 9 STP SUMP UNLEADED SUMP FUEL ALARM CLEAR 12-15-20 3:37PM L12 ANNULAR UNLEADED ANNULAR FUEL ALARM ALARM 12-15-20 3:33PM L12 ANNULAR UNLEADED ANNULAR FUEL ALARM CLEAR 12-15-20 3:31PM L 9 STP SUMP UNLEADED SUMP SENSOR OUT ALARM CLEAR 12-15-20 3:26PM L 9 STP SUMP UNLEADED SUMP FUEL ALARM ALARM 12-15-20 3:26PM L 9 STP SUMP UNLEADED SUMP SENSOR OUT ALARM ALARM 12-15-20 3:20PM I11200 DEC 15, 2020 6:19 PM 286917 SPARKLING IMA 2301 H ST. BAKERSFIELD,CA 93301 661-324-8455 NON-PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME OTHER ISD GROSS PRES WARN CLEAR 12-15-20 11:18AM OTHER ISD GROSS PRES WARN ALARM 12-15-20 9:25AM SYSTEM PRINTER ERROR CLEAR 12-15-20 8:55AM SYSTEM PAPER OUT CLEAR 12-15-20 8:55AM SYSTEM PRINTER ERROR ALARM 12-15-20 8:54AM SYSTEM PAPER OUT ALARM 12-15-20 8:54AM OTHER ISD GROSS PRES WARN CLEAR 12-08-20 10:53AM OTHER ISD GROSS PRES WARN ALARM 12-03-20 9:25AM SYSTEM PRINTER ERROR CLEAR 11-30-20 4:28PM SYSTEM PAPER OUT CLEAR 11-30-20 4:28PM SYSTEM PRINTER ERROR ALARM 11-30-20 4:28PM SYSTEM PAPER OUT ALARM 11-30-20 4:28PM SYSTEM PRINTER ERROR CLEAR 11-30-20 4:28PM SYSTEM PAPER OUT CLEAR 11-30-20 4:28PM SYSTEM PRINTER ERROR ALARM 11-30-20 4:24PM SYSTEM PAPER OUT ALARM 11-30-20 4:24PM OTHER ISD GROSS PRES WARN CLEAR 11-26-20 9:22AM OTHER ISD GROSS PRES WARN ALARM 11-19-20 9:24AM OTHER ISD GROSS PRES WARN CLEAR 11-12-20 9:22AM SYSTEM PRINTER ERROR CLEAR 11-09-20 10:43AM SYSTEM PAPER OUT CLEAR 11-09-20 10:43AM SYSTEM PAPER OUT ALARM 11-09-20 10:41AM SYSTEM PRINTER ERROR ALARM 11-09-20 10:41AM OTHER ISD SENSOR OUT WARN CLEAR 11-08-20 9:24AM OTHER ISD SENSOR OUT WARN ALARM 11-07-20 9:24AM OTHER ISD GROSS PRES WARN ALARM 11-05-20 9:27AM SYSTEM PRINTER ERROR CLEAR 10-22-20 8:00AM SYSTEM PAPER OUT CLEAR 10-22-20 8:00AM SYSTEM PAPER OUT ALARM 10-22-20 7:58AM SYSTEM PRINTER ERROR ALARM 10-22-20 7:58AM SYSTEM PRINTER ERROR CLEAR 10-22-20 7:57AM SYSTEM PAPER OUT CLEAR 10-22-20 7:57AM SYSTEM PRINTER ERROR ALARM 10-18-20 7:35AM SYSTEM PAPER OUT ALARM 10-18-20 7:35AM SYSTEM PRINTER ERROR CLEAR 10-03-20 8:05PM SYSTEM PAPER OUT CLEAR 10-03-20 8:05PM SYSTEM PAPER OUT ALARM 10-03-20 8:04PM SYSTEM PRINTER ERROR ALARM 10-03-20 8:04PM SYSTEM PRINTER ERROR CLEAR 10-03-20 8:01PM SYSTEM PAPER OUT CLEAR 10-03-20 8:01PM SYSTEM PAPER OUT ALARM 10-03-20 8:00PM SYSTEM PRINTER ERROR ALARM 10-03-20 8:00PM SYSTEM PRINTER ERROR CLEAR 10-03-20 8:00PM SYSTEM PAPER OUT CLEAR 10-03-20 8:00PM SYSTEM PAPER OUT ALARM 10-03-20 8:00PM SYSTEM PRINTER ERROR ALARM 10-03-20 8:00PM SYSTEM PRINTER ERROR CLEAR 10-03-20 8:00PM SYSTEM PRINTER ERROR ALARM 10-03-20 7:59PM SYSTEM PRINTER ERROR CLEAR 10-03-20 7:59PM SYSTEM PRINTER ERROR ALARM 10-03-20 7:59PM I20600 DEC 15, 2020 6:19 PM 286917 SPARKLING IMA 2301 H ST. BAKERSFIELD,CA 93301 661-324-8455 TANK ALARM HISTORY TANK 1 UNLEADED 87 OVERFILL ALARM NOV 2, 2020 2:36 AM PROBE OUT DEC 15, 2020 5:47 PM DEC 15, 2020 5:33 PM DEC 15, 2020 2:56 PM TANK 2 SUPREME 91 DELIVERY NEEDED JUL 18, 2020 9:15 PM TANK 3 DIESEL TANK 5 TANK 6 TANK 7 TANK 8 TANK 9 TANK 10 TANK 11 TANK 12 TANK 13 TANK 14 TANK 15 TANK 16 I38200 DEC 15, 2020 6:19 PM I30200 DEC 15, 2020 6:19 PM 286917 SPARKLING IMA 2301 H ST. BAKERSFIELD,CA 93301 661-324-8455 LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 DISP. 1-2 DEC 15, 2020 12:18 PM SENSOR OUT ALARM DEC 15, 2020 11:27 AM FUEL ALARM JUN 18, 2020 8:40 AM SENSOR OUT ALARM 2 DISP. 3-4 DEC 15, 2020 12:18 PM SENSOR OUT ALARM DEC 15, 2020 11:27 AM FUEL ALARM JUN 18, 2020 8:40 AM SENSOR OUT ALARM 3 DISP. 11-12 DEC 15, 2020 12:19 PM SENSOR OUT ALARM DEC 15, 2020 11:28 AM FUEL ALARM JUN 18, 2020 8:40 AM SENSOR OUT ALARM 4 DISP. 7-8 DEC 15, 2020 12:19 PM SENSOR OUT ALARM DEC 15, 2020 11:34 AM FUEL ALARM DEC 15, 2020 11:32 AM FUEL ALARM 5 DISP. 9-10 DEC 15, 2020 12:18 PM SENSOR OUT ALARM DEC 15, 2020 11:38 AM FUEL ALARM DEC 15, 2020 11:30 AM FUEL ALARM 6 DISP 5-6 DEC 15, 2020 12:18 PM SENSOR OUT ALARM DEC 15, 2020 11:29 AM FUEL ALARM JUN 18, 2020 8:40 AM SENSOR OUT ALARM 7 DISP. 13-14 DEC 15, 2020 12:18 PM SENSOR OUT ALARM DEC 15, 2020 11:28 AM FUEL ALARM JUN 18, 2020 8:40 AM SENSOR OUT ALARM 8 DISP. 15-16 DEC 15, 2020 12:19 PM SENSOR OUT ALARM DEC 15, 2020 11:26 AM FUEL ALARM JUN 18, 2020 8:40 AM SENSOR OUT ALARM 9 UNLEADED SUMP DEC 15, 2020 5:49 PM SENSOR OUT ALARM DEC 15, 2020 5:46 PM SENSOR OUT ALARM DEC 15, 2020 5:46 PM SENSOR OUT ALARM 10 SUPREME SUMP DEC 15, 2020 12:18 PM SENSOR OUT ALARM DEC 15, 2020 11:36 AM FUEL ALARM JUN 18, 2020 8:40 AM SENSOR OUT ALARM 11 DIESEL SUMP DEC 15, 2020 12:18 PM SENSOR OUT ALARM DEC 15, 2020 11:36 AM FUEL ALARM JUN 18, 2020 8:40 AM SENSOR OUT ALARM 12 UNLEADED ANNULAR DEC 15, 2020 5:41 PM FUEL ALARM DEC 15, 2020 5:22 PM FUEL ALARM DEC 15, 2020 3:33 PM FUEL ALARM 13 SUPREME ANNULAR DEC 15, 2020 12:18 PM FUEL ALARM DEC 15, 2020 11:58 AM FUEL ALARM JUN 18, 2020 8:32 AM FUEL ALARM 14 DIESEL ANNULAR DEC 15, 2020 12:18 PM FUEL ALARM DEC 15, 2020 11:49 AM FUEL ALARM JUN 18, 2020 8:40 AM FUEL ALARM I31600 DEC 15, 2020 6:19 PM 286917 SPARKLING IMA 2301 H ST. BAKERSFIELD,CA 93301 661-324-8455 SMART SENSOR ALARM HISTORY REPORT SENSOR LOCATION 1 FM 1-2 DEC 13, 2019 8:39 AM COMMUNICATION ALARM 2 FM 3-4 DEC 13, 2019 8:39 AM COMMUNICATION ALARM 3 FM 5-6 DEC 13, 2019 8:39 AM COMMUNICATION ALARM 4 FM 7-8 5 FM 9-10 DEC 13, 2019 8:39 AM COMMUNICATION ALARM 6 FM 11-12 DEC 13, 2019 8:39 AM COMMUNICATION ALARM 7 FM 13-14 DEC 13, 2019 8:39 AM COMMUNICATION ALARM 8 PRESSURE SENSOR 9 FM 15-16 I40200 DEC 15, 2020 6:19 PM I40300 DEC 15, 2020 6:19 PM I34200 DEC 15, 2020 6:19 PM I34700 DEC 15, 2020 6:19 PM IV0100 DEC 15, 2020 6:19 PM 286917 SPARKLING IMA 2301 H ST. BAKERSFIELD,CA 93301 661-324-8455 ISD ALARM STATUS REPORT EVR TYPE: VACUUM ASSIST ISD TYPE: 01.06 VAPOR PROCESSOR TYPE: NONE OVERALL STATUS :WARN EVR VAPOR COLLECTION :PASS EVR VAPOR CONTAINMENT :WARN ISD MONITOR UP-TIME :100% EVR/ISD PASS TIME : 0% WARNING ALARMS DATE TIME DESCRIPTION READING VALUE 20-12-15 09:25:25 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.50 20-12-08 09:24:50 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.52 20-12-07 09:24:58 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.52 20-12-06 09:25:11 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.50 20-12-05 09:25:31 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.52 20-12-04 09:25:51 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.52 20-12-03 09:25:46 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.52 20-11-25 09:26:13 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.46 20-11-24 09:26:14 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.51 20-11-23 09:25:22 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.52 FAILURE ALARMS DATE TIME DESCRIPTION READING VALUE 20-11-26 09:26:56 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.30 20-11-12 09:24:44 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.55 20-05-04 09:26:50 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 24.17 20-04-07 09:26:07 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 18.27 19-08-03 10:03:31 A/L RATIO GROSS BLOCKAGE FP 6 BLEND3 BLKD 19-07-03 10:03:50 SENSOR OUT SELFTEST s 9 19-07-02 10:06:28 SENSOR OUT SELFTEST s 9 19-07-01 10:05:29 SENSOR OUT SELFTEST s 9 19-06-30 10:05:10 SENSOR OUT SELFTEST s 9 19-06-29 10:02:43 SENSOR OUT SELFTEST s 9 SHUTDOWN & MISCELLANEOUS EVENTS DATE TIME DESCRIPTION ACTION/NAME 20-12-15 12:20:10 READINESS ISD:PP EVR:NN EVR READINESS PENDING 20-12-15 12:20:10 ISD STARTUP 20-12-15 12:20:06 ISD SHUTDOWN 20-12-15 11:18:48 CONTAINMENT GROSS & DEGRD TEST MANUALLY CLEARED 20-12-08 10:53:09 CONTAINMENT GROSS & DEGRD TEST MANUALLY CLEARED 20-11-26 09:53:03 CONTAINMENT GROSS & DEGRD TEST MANUALLY CLEARED 20-11-26 09:26:56 CONTAINMENT GROSS DISABLED DISPENSERS 20-11-12 10:01:19 CONTAINMENT GROSS & DEGRD TEST MANUALLY CLEARED 20-11-12 09:57:30 CONTAINMENT GROSS & DEGRD TEST MANUALLY CLEARED 20-11-12 09:24:44 CONTAINMENT GROSS DISABLED DISPENSERS Appendix VIII Underground Storage Tank Spill Container Testing Report Form CERS = California Environmental Reporting System, ID = Identification, ICC = International Code Council Page 1 of 2 TYPE OF ACTION ܆܆ Installation ܆ Repair ܆ 12 Month 1. FACILITY INFORMATION CERS ID Test Date Facility Name Facility Address City ZIP Code 2. SERVICE TECHNICIAN INFORMATION Company Performing the Test Phone Mailing Address Service Technician Performing Test Contractor/Tank Tester License Number ICC Number ICC Expiration Date 3. TRAINING AND CERTIFICATIONS Manufacturer and Test Equipment Training Certifications Expiration Date 4. TEST PROCEDURE INFORMATION Test Procedures Used Components Tested 5. CERTIFICATION BY SERVICE TECHNICIAN CONDUCTING TEST I hereby certify that each spill container was tested in accordance with California Code of Regulations, title 23, division 3, chapter 16, section 2637.1; that required supporting documentation is attached; and all information contained herein is accurate. I understand that test procedures shall be made available upon request by the governing authority. Service Technician Signature Date Total # of Pages 10123120 12/15/2020 Sparkling Image Car Wash (204) 2301 H Street Bakersfield 93301 Confidence UST Services, Inc.(800) 339-9930 16250 Meacham Road, Bakersfield, CA 93314 Payton Phillips 804904 9482312 1-30-2022 Veedor Root c27796 07-29-2022 FFS 1016783712 12-04-2022 Lake Test Phil-Tite Spill Buckets And Vapor Buckets 12/15/2020 2 Underground Storage Tank Spill Container Testing Report Form Additional copies of this page may be attached. Page 2 of 2 6. SPILL CONTAINER DETAILS Test Method Developed by ܆܆ Manufacturer ܆܆ Industry Standard ܆܆ Professional Engineer Test Type ܆܆ Pressure ܆܆ Vacuum ܆܆ Hydrostatic Tank ID Spill Container Manufacturer: Method of Cathodic Protection ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other Is the spill container minimum capacity five gallons excluding riser volume? ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* Method to keep spill container empty ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other Spill Container Test Results ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail Tank ID Spill Container Manufacturer: Method of Cathodic Protection ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other Is the spill container minimum capacity five gallons excluding riser volume? ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* Method to keep spill container empty ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other Spill Container Test Results ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail 1 8. COMMENTS Describe all answers marked “Other,” “No,” or “Fail” and each proposed remedy. * Mark here if: Spill containers do not have a minimum capacity of five gallons and require replacement. T1 87 Phil-Tite T2 91 Phil-Tite T3 DSL Phil-Tite