Loading...
HomeMy WebLinkAbout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ame as Facility Name or DBA-Doing Business As) %XVLQHVV6LWH$GGUHVV &LW\ =,3&RGH ,, 81'(5*5281'6725$*(7$1.6(59,&(7(&+1,&,$1,1)250$7,21 1DPHRI&RPSDQ\3HUIRUPLQJWKH&HUWLILFDWLRQ 3KRQH 0DLOLQJ$GGUHVV 1DPHRI8676HUYLFH7HFKQLFLDQ3HUIRUPLQJWKH&HUWLILFDWLRQ(Print as shown on the ICC Certification) &RQWUDFWRU7DQN7HVWHU/LFHQVH ,&&&HUWLILFDWLRQ ,&&&HUWLILFDWLRQ([SLUDWLRQ'DWH 0RQLWRULQJ6\VWHP7UDLQLQJDQG&HUWLILFDWLRQV(List all applicable certifications.) ([SLUDWLRQ'DWH ,,, 5(68/762)7(67,1*6(59,&,1* Indicate and attach the following reports if the monitoring equipment is capable of generating either.<11$0RQLWRULQJ6\VWHP6HWXS$ODUP+LVWRU\5HSRUW :DVDQ\PRQLWRULQJHTXLSPHQWUHSODFHG" (If “Yes,” identify the specific devices replaced and list the manufacturer and model for all replacement parts in section IV below.) :DVGDPDJHGHEULVRUOLTXLGIRXQGLQVLGHDQ\VHFRQGDU\FRQWDLQPHQWV\VWHPV" (If “Yes,” describe what was found in section IV below.) ,VDOOPRQLWRULQJHTXLSPHQWRSHUDWLRQDOSHUPDQXIDFWXUHU¶VVSHFLILFDWLRQV" (If “No,” describe why in section IV below.) ,9 &200(176 If directed to use this section, describe how and when the issues were or will be corrected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aco #7781 Fastrip #22 (South) 4013 S "H" St Bakersfield 93304 16250 Meacham Road, Bakersfield, CA 93314 Aaron Perrigo 804904 8485827 9/16/2020 Veeder Root B47853 8/3/2020 Replaced bellows on 87-2 spill bucket Confidence UST Services, Inc. (800) 339-9930 ,' ,GHQWLILFDWLRQ6: 6LQJOH:DOOHG93+ 9DFXXP3UHVVXUH+\GURVWDWLF//' /LQH/HDN'HWHFWRU 81 ZZZXQLGRFVRUJ 5HY 81'(5*5281'6725$*(7$1. 021,725,1*6<67(0&(57,),&$7,21)250 3DJHRI  9, ,19(1725<2)(48,30(17&(57,),(' A separate Monitoring System Certification Form must be prepared for each monitoring system control panel. 0DNHRI0RQLWRULQJ6\VWHP&RQWURO3DQHO  0RGHORI0RQLWRULQJ6\VWHP&RQWURO3DQHO  6RIWZDUH9HUVLRQ,QVWDOOHG  Check the appropriate boxes to indicate specific equipment inspected/serviced. 0RQLWRULQJ'HYLFH8VHG'HYLFH0RGHO0RQLWRULQJ'HYLFH8VHG'HYLFH0RGHO 7$1.,' (By tank number, stored product, etc.) 7$1.,' (By tank number, stored product, etc.) ,Q7DQN*DXJLQJ(SW Tank),Q7DQN*DXJLQJ(SW Tank) $QQXODU6SDFHRU9DXOW6HQVRU$QQXODU6SDFHRU9DXOW6HQVRU 93+6HQVRU93+6HQVRU 3URGXFW3LSLQJ3URGXFW3LSLQJ 0HFKDQLFDO//'0HFKDQLFDO//' (OHFWURQLF//'(OHFWURQLF//' 93+6HQVRU 3LSLQJ 93+6HQVRU 3LSLQJ  6XPS6HQVRU6XPS6HQVRU 93+6HQVRU 6XPS 93+6HQVRU 6XPS  )LOO3LSLQJ)LOO3LSLQJ 93+6HQVRU 3LSLQJ 93+6HQVRU 3LSLQJ  6XPS6HQVRU6XPS6HQVRU 93+6HQVRU 6XPS 93+6HQVRU 6XPS  9HQW3LSLQJ9HQW3LSLQJ 93+6HQVRU 3LSLQJ 93+6HQVRU 3LSLQJ  6XPS6HQVRU6XPS6HQVRU 93+6HQVRU 6XPS 93+6HQVRU 6XPS  9DSRU5HFRYHU\3LSLQJ9DSRU5HFRYHU\3LSLQJ 93+6HQVRU 3LSLQJ 93+6HQVRU 3LSLQJ  6XPS6HQVRU6XPS6HQVRU 93+6HQVRU 6XPS 93+6HQVRU 6XPS  0RQLWRULQJ'HYLFH8VHG 'HYLFH0RGHO0RQLWRULQJ'HYLFH8VHG 'HYLFH0RGHO 7$1.,' (By tank number, stored product, etc.) 7$1.,' (By tank number, stored product, etc.) ,Q7DQN*DXJLQJ(SW Tank),Q7DQN*DXJLQJ(SW Tank) $QQXODU6SDFHRU9DXOW6HQVRU$QQXODU6SDFHRU9DXOW6HQVRU 93+6HQVRU93+6HQVRU 3URGXFW3LSLQJ3URGXFW3LSLQJ 0HFKDQLFDO//'0HFKDQLFDO//' (OHFWURQLF//'(OHFWURQLF//' 93+6HQVRU 3LSLQJ 93+6HQVRU 3LSLQJ  6XPS6HQVRU6XPS6HQVRU 93+6HQVRU 6XPS 93+6HQVRU 6XPS  )LOO3LSLQJ)LOO3LSLQJ 93+6HQVRU 3LSLQJ 93+6HQVRU 3LSLQJ  6XPS6HQVRU6XPS6HQVRU 93+6HQVRU 6XPS 93+6HQVRU 6XPS  9HQW3LSLQJ9HQW3LSLQJ 93+6HQVRU 3LSLQJ 93+6HQVRU 3LSLQJ  6XPS6HQVRU6XPS6HQVRU 93+6HQVRU 6XPS 93+6HQVRU 6XPS  9DSRU5HFRYHU\3LSLQJ9DSRU5HFRYHU\3LSLQJ 93+6HQVRU 3LSLQJ 93+6HQVRU 3LSLQJ  6XPS6HQVRU6XPS6HQVRU 93+6HQVRU 6XPS 93+6HQVRU 6XPS  Veeder Root TLS-350 333.02 T1 Unl 1 847390-107 794390-420 FX1V 794380-208 T2 Unl 2 847390-107 794390-420 794380-208 T3 PNL 847390-107 794390-420 FX1V 794380-208 T4 Diesel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pecify in section VII.)2WKHU(Specify in section VII.) 2WKHU0RQLWRUHG&RPSRQHQW,'2WKHU0RQLWRUHG&RPSRQHQW,' 2WKHU(Specify in section VII.)2WKHU(Specify in section VII.) 2WKHU0RQLWRUHG&RPSRQHQW,'2WKHU0RQLWRUHG&RPSRQHQW,' 2WKHU(Specify in section VII.)2WKHU(Specify in section VII.) Include information for every underground storage tank component monitored by this monitoring system control panel. If the monitoring system control panel monitors more components than this form accommodates, additional copies of these pages may be attached. 9,, &200(176 Use this section to provide additional comments about the inventory of the equipment certified.  1-2 794380-208 3-4 794380-208 5-6 794380-208 7-8 794380-208 < <HV1 1R1$ 1RW$SSOLFDEOH 81 ZZZXQLGRFVRUJ 5HY 81'(5*5281'6725$*(7$1. 021,725,1*6<67(0&(57,),&$7,21)250 3DJHRI  9,,, 021,725,1*6<67(0$1'352*5$00,1* This section must be completed if a monitoring panel is used to perform leak detection monitoring.<11$ $UHWKHYLVXDODQGDXGLEOHDODUPVRSHUDWLRQDO" :HUHDOOVHQVRUVYLVXDOO\LQVSHFWHGIRUNLQNVDQGEUHDNVLQWKHFDEOHVDQGIRUUHVLGXDOEXLOGXSWRHQVXUHWKDWIORDWVPRYHIUHHO\ IXQFWLRQDOO\WHVWHGDQGFRQILUPHGRSHUDWLRQDO" :HUHDOOVHQVRUVLQVWDOOHGDWORZHVWSRLQWRIVHFRQGDU\FRQWDLQPHQWDQGSRVLWLRQHGVRWKDWRWKHUHTXLSPHQWZLOOQRWLQWHUIHUHZLWK WKHLUSURSHURSHUDWLRQ" :DVPRQLWRULQJV\VWHPVHWXSUHYLHZHGWRHQVXUHSURSHUVHWWLQJV" :DVWKHPRQLWRULQJSDQHO¶VEDFNXSEDWWHU\YLVXDOO\LQVSHFWHGIXQFWLRQDOO\WHVWHGDQGFRQILUPHGRSHUDWLRQDO" 'RHVWKHIORZRIIXHOVWRSDWWKHGLVSHQVHULIDOHDNLVGHWHFWHGLQWKHXQGHUGLVSHQVHUFRQWDLQPHQW" 'RHVWKHWXUELQHDXWRPDWLFDOO\VKXWGRZQLIWKHSLSLQJVHFRQGDU\FRQWDLQPHQWPRQLWRULQJV\VWHPIDLOVWRRSHUDWHRULVHOHFWULFDOO\ GLVFRQQHFWHG" 'RHVWKHWXUELQHDXWRPDWLFDOO\VKXWGRZQLIWKHSLSLQJVHFRQGDU\FRQWDLQPHQWPRQLWRULQJV\VWHPGHWHFWVDOHDN" :KLFKVHQVRUVLQLWLDWHSRVLWLYHVKXWGRZQ"(Check all that apply.)6XPS8QGHU'LVSHQVHU&RQWDLQPHQW ,IDODUPVDUHUHOD\HGWRDUHPRWHPRQLWRULQJVWDWLRQLVDOOFRPPXQLFDWLRQVHTXLSPHQW HJPRGHP RSHUDWLRQDO" For any answer of “N” above, describe in Section IX how and when these deficiencies were or will be corrected. ,; &200(176 ; ,17$1.*$8*,1*7(67,1* &KHFNWKLVER[LIWDQNJDXJLQJLVXVHGRQO\IRULQYHQWRU\FRQWURO(Do not complete this section.) <11$&KHFNWKLVER[LI12WDQNJDXJLQJHTXLSPHQWLVLQVWDOOHG (Do not complete this section.) This section must be completed if in-tank gauging is used to perform leak detection monitoring. +DVDOOLQSXWZLULQJEHHQLQVSHFWHGIRUNLQNVDQGEUHDNVLQWKHFDEOHVDQGIRUSURSHUHQWU\DQGWHUPLQDWLRQLQFOXGLQJWHVWLQJIRU JURXQGIDXOWV" :HUHDOOLQWDQNJDXJLQJSUREHVYLVXDOO\LQVSHFWHGIRUGDPDJHDQGUHVLGXHEXLOGXSWRHQVXUHWKDWIORDWVPRYHIUHHO\IXQFWLRQDOO\ WHVWHGDQGFRQILUPHGRSHUDWLRQDO" :DVDFFXUDF\RIV\VWHP¶VSURGXFWOHYHOUHDGLQJVWHVWHG" :DVDFFXUDF\RIV\VWHP¶VZDWHUOHYHOUHDGLQJVWHVWHG" :HUHDOOSUREHVUHLQVWDOOHGSURSHUO\" :HUHDOOLWHPVRQWKHHTXLSPHQWPDQXIDFWXUHU¶VPDLQWHQDQFHFKHFNOLVWFRPSOHWHG" For any answer of “N” above, describe in Section XI how and when these deficiencies were or will be corrected. ;, &200(176 *3+ *DOORQV3HU+RXU< <HV1 1R1$ 1RW$SSOLFDEOH93+ 9DFXXP3UHVVXUH+\GURVWDWLF,' ,GHQWLILFDWLRQ 81 ZZZXQLGRFVRUJ5HY 81'(5*5281'6725$*(7$1. 021,725,1*6<67(0&(57,),&$7,21)250 3DJHRI  ;,, /,1(/($.'(7(&7257(67,1* &KHFNWKLVER[LIOLQHOHDNGHWHFWRUV //' DUH127LQVWDOOHG(Do not complete this section.)<11$This section must be completed if LLDs are installed. :DVDOHDNVLPXODWHGWRYHULI\//'SHUIRUPDQFH" (Check all that apply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¶VPDLQWHQDQFHFKHFNOLVWFRPSOHWHG" :HUHDOO//'VFRQILUPHGRSHUDWLRQDOZLWKLQUHJXODWRU\UHTXLUHPHQWV" For any answer of “N” above, describe in Section XIII how and when these issues were or will be corrected. ;,,, &200(176 ;,9 9$&88035(6685(+<'5267$7,&021,725,1*(48,30(177(67,1* &KHFNWKLVER[LI93+PRQLWRULQJLV127XVHG(Do not complete this section.) This section must be completed if VPH monitoring is used to perform leak detection monitoring. 6\VWHP7\SH 0DUNDOOWKDWDSSO\ 9DFXXP3UHVVXUH+\GURVWDWLF 6HQVRU,'&RPSRQHQW 6 0RQLWRUHG%\7KLV6HQVRU 6HQVRU)XQFWLRQDOLW\ 7HVW ,QWHUVWLWLDO&RPPXQLFDWLRQ 7HVW 3DVV )DLO 3DVV )DLO 3DVV)DLO3DVV)DLO 3DVV)DLO3DVV)DLO 3DVV)DLO3DVV)DLO 3DVV)DLO3DVV)DLO 3DVV)DLO3DVV)DLO 3DVV)DLO3DVV)DLO 3DVV)DLO3DVV)DLO 3DVV)DLO3DVV)DLO 3DVV)DLO3DVV)DLO 3DVV)DLO3DVV)DLO 3DVV)DLO3DVV)DLO +RZZDVLQWHUVWLWLDOFRPPXQLFDWLRQYHULILHG"6LPXODWHG/HDNDW)DU(QGVRIWKH,QWHUVWLWLDO6SDFH9LVXDO,QVSHFWLRQ 2WKHU(Describe the method in section XV below.)*DXJH :DVWKHYDFXXPRUSUHVVXUHUHVWRUHGWRRSHUDWLQJOHYHOVLQDOOLQWHUVWLWLDOVSDFHV"<HV1R(Describe the reason in section XV below.) For any answer of “Fail” above, describe in Section XV how and when these issues were or will be corrected. ;9 &200(176 Jaco 7781 Setup Responses Received: 200 FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 JUL 27, 2020 9:09 AM TANK PRODUCT GALLONS INCHES WATER DEG F ULLAGE 1 UNL 1 8652 75.18 0.0 82.9 3410 2 UNL 2 8758 76.00 0.0 83.5 3304 3 PNL 8309 72.55 0.8 85.2 3753 4 DIESEL 2017 24.96 0.0 82.5 10045 I90500 JUL 27, 2020 9:09 AM SOFTWARE REVISION LEVEL VERSION 333.02 SOFTWARE# 346333-100-C CREATED - 12.08.10.11.22 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD/APM I50500 JUL 27, 2020 9:09 AM SYSTEM TYPE AND LANGUAGE FLAG SYSTEM UNITS U.S. SYSTEM LANGUAGE ENGLISH SYSTEM DATE/TIME FORMAT MON DD YYYY HH:MM:SS xM I50201 JUL 27, 2020 9:09 AM SHIFT TIME 1 : 6:00 AM I50202 JUL 27, 2020 9:09 AM SHIFT TIME 2 : DISABLED I50203 JUL 27, 2020 9:09 AM SHIFT TIME 3 : DISABLED I50204 JUL 27, 2020 9:09 AM SHIFT TIME 4 : DISABLED I54600 JUL 27, 2020 9:09 AM TANK PER TST NEEDED WRN: DISABLED I54900 JUL 27, 2020 9:09 AM TANK ANN TST NEEDED WRN: DISABLED I55300 JUL 27, 2020 9:09 AM LINE RE-ENABLE METHOD PASS LINE TEST I55600 JUL 27, 2020 9:09 AM LINE PER TST NEEDED WRN: DISABLED I55900 JUL 27, 2020 9:09 AM LINE ANN TST NEEDED WRN: DISABLED I50D00 JUL 27, 2020 9:09 AM PRINT TC VOLUMES ENABLED I50E00 JUL 27, 2020 9:09 AM TEMP COMPENSATION VALUE (DEG F ): 60.0 I60B00 JUL 27, 2020 9:09 AM STICK HEIGHT OFFSET ENABLE STATUS DISABLED I51400 JUL 27, 2020 9:09 AM H-PROTOCOL DATA FORMAT HEIGHT I51A01 JUL 27, 2020 9:09 AM DAYLIGHT SAVING TIME ENABLED ON I51B00 JUL 27, 2020 9:09 AM DAYLIGHT SAVING TIME START DATE MAR WEEK 2 SUN 2:00 AM END DATE NOV WEEK 1 SUN 2:00 AM I51600 JUL 27, 2020 9:09 AM RE-DIRECT LOCAL PRINTOUT DISABLED I50400 JUL 27, 2020 9:09 AM 232 SECURITY CODE PORT SECURITY CODE STATUS 1 000000 DISABLED 2 000000 DISABLED 3 000000 DISABLED 4 000000 DISABLED 5 000000 DISABLED 6 000000 DISABLED I21900 JUL 27, 2020 9:09 AM TANK CHART SECURITY DISABLED I5BD00 JUL 27, 2020 9:09 AM CUSTOM ALARM LABELS DISABLED I56000 JUL 27, 2020 9:09 AM MASS/DENSITY DISABLED I88101 JUL 27, 2020 9:09 AM PORT SETTINGS: COMM BOARD : 1 (RS-232) BAUD RATE : 9600 PARITY : NONE STOP BIT : 1 STOP DATA LENGTH: 8 DATA RS-232 SECURITY CODE : DISABLED I88102 JUL 27, 2020 9:09 AM PORT SETTINGS: COMM BOARD : 2 (RS-232) BAUD RATE : 9600 PARITY : NONE STOP BIT : 1 STOP DATA LENGTH: 8 DATA RS-232 SECURITY CODE : DISABLED I88103 JUL 27, 2020 9:09 AM PORT SETTINGS: COMM BOARD : 3 (EDIM ) RS-232 SECURITY CODE : DISABLED I88104 JUL 27, 2020 9:09 AM I88105 JUL 27, 2020 9:09 AM I88106 JUL 27, 2020 9:09 AM I52000 JUL 27, 2020 9:09 AM RECEIVER AUTO DIAL TYPE & START TIME RCVR LOCATION LABEL DIAL TYPE START TIME 1 ON DATE JUL 11, 2017 DISABLED 2 ON DATE JUL 11, 2017 DISABLED 3 ON DATE JUL 11, 2017 DISABLED 4 ON DATE JUL 11, 2017 DISABLED 5 ON DATE JUL 11, 2017 DISABLED 6 ON DATE JUL 11, 2017 DISABLED 7 ON DATE JUL 11, 2017 DISABLED 8 ON DATE JUL 11, 2017 DISABLED I60100 JUL 27, 2020 9:09 AM TANK CONFIGURATION DEVICE LABEL CONFIGURED 1 UNL 1 ON 2 UNL 2 ON 3 PNL ON 4 DIESEL ON I60200 JUL 27, 2020 9:09 AM TANK PRODUCT LABEL TANK PRODUCT LABEL 1 UNL 1 2 UNL 2 3 PNL 4 DIESEL I60300 JUL 27, 2020 9:09 AM TANK PRODUCT CODE TANK PRODUCT LABEL 1 UNL 1 1 2 UNL 2 2 3 PNL 3 4 DIESEL 4 I60900 JUL 27, 2020 9:09 AM TANK THERMAL COEFFICIENT TANK PRODUCT LABEL 1 UNL 1 0.000700 2 UNL 2 0.000700 3 PNL 0.000700 4 DIESEL 0.000450 I60700 JUL 27, 2020 9:09 AM TANK DIAMETER TANK PRODUCT LABEL INCHES 1 UNL 1 111.50 2 UNL 2 111.50 3 PNL 111.50 4 DIESEL 111.50 I60A00 JUL 27, 2020 9:09 AM TANK FULL VOLUME TANK PRODUCT LABEL TANK PROFILE GALLONS 1 UNL 1 1 PT 12062 2 UNL 2 1 PT 12062 3 PNL 1 PT 12062 4 DIESEL 1 PT 12062 I60400 JUL 27, 2020 9:10 AM TANK FULL VOLUME TANK PRODUCT LABEL GALLONS 1 UNL 1 12062 2 UNL 2 12062 3 PNL 12062 4 DIESEL 12062 I60500 JUL 27, 2020 9:10 AM TANK 4 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 UNL 1 12062 0 0 0 2 UNL 2 12062 0 0 0 3 PNL 12062 0 0 0 4 DIESEL 12062 0 0 0 I60600 JUL 27, 2020 9:10 AM TANK 20 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 UNL 1 12062 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 UNL 2 12062 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3 PNL 12062 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4 DIESEL 12062 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 I61500 JUL 27, 2020 9:10 AM TANK PRODUCT LABEL METER DATA 1 UNL 1 NO 2 UNL 2 NO 3 PNL NO 4 DIESEL NO I62F00 JUL 27, 2020 9:10 AM MAG PROBE FLOAT SIZE TANK PRODUCT LABEL FLOAT SIZE: 1 UNL 1 4.0 IN. 2 UNL 2 3.0 IN. 3 PNL 4.0 IN. 4 DIESEL 4.0 IN. I62700 JUL 27, 2020 9:10 AM TANK HIGH WATER WARNING LIMIT TANK PRODUCT LABEL INCHES 1 UNL 1 2.0 2 UNL 2 2.0 3 PNL 2.0 4 DIESEL 2.0 I64200 JUL 27, 2020 9:10 AM WATER ALARM FILTER TANK PRODUCT LABEL 1 UNL 1 LOW 2 UNL 2 LOW 3 PNL LOW 4 DIESEL LOW I62400 JUL 27, 2020 9:10 AM TANK HIGH WATER LEVEL LIMIT TANK PRODUCT LABEL INCHES 1 UNL 1 3.0 2 UNL 2 3.0 3 PNL 3.0 4 DIESEL 3.0 I62800 JUL 27, 2020 9:10 AM TANK MAXIMUM VOLUME LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 1 12062 2 UNL 2 12062 3 PNL 12062 4 DIESEL 12062 I62300 JUL 27, 2020 9:10 AM TANK OVERFILL LEVEL LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 1 10856 2 UNL 2 10856 3 PNL 10856 4 DIESEL 10856 I62200 JUL 27, 2020 9:10 AM TANK HIGH PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 1 11459 2 UNL 2 11459 3 PNL 11459 4 DIESEL 11459 I62900 JUL 27, 2020 9:10 AM TANK DELIVERY REQUIRED LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 1 1809 2 UNL 2 1809 3 PNL 1809 4 DIESEL 1809 I62100 JUL 27, 2020 9:10 AM TANK LOW PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 1 500 2 UNL 2 500 3 PNL 500 4 DIESEL 500 I62600 JUL 27, 2020 9:10 AM TANK LEAK ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 1 99 2 UNL 2 99 3 PNL 99 4 DIESEL 99 I62500 JUL 27, 2020 9:10 AM TANK SUDDEN LOSS LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 1 99 2 UNL 2 150 3 PNL 99 4 DIESEL 99 I60800 JUL 27, 2020 9:10 AM TANK TILT TANK PRODUCT LABEL INCHES 1 UNL 1 2.00 2 UNL 2 2.00 3 PNL 0.00 4 DIESEL 0.00 I60B00 JUL 27, 2020 9:10 AM STICK HEIGHT OFFSET ENABLE STATUS DISABLED I60C00 JUL 27, 2020 9:10 AM TANK STICK HEIGHT OFFSET TANK PRODUCT LABEL INCHES 1 UNL 1 0.00 2 UNL 2 0.00 3 PNL 0.00 4 DIESEL 0.00 I61200 JUL 27, 2020 9:10 AM TANK MANIFOLDED PARTNERS TANK PRODUCT LABEL SIPHON MANIFOLDED TANKS LINE MANIFOLDED TANKS 1 UNL 1 NONE NONE 2 UNL 2 NONE NONE 3 PNL NONE NONE 4 DIESEL NONE NONE I63600 JUL 27, 2020 9:10 AM PERIODIC LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 UNL 1 120 2 UNL 2 120 3 PNL 120 4 DIESEL 120 I62A00 JUL 27, 2020 9:10 AM ANNUAL LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 UNL 1 120 2 UNL 2 120 3 PNL 120 4 DIESEL 120 I62C00 JUL 27, 2020 9:10 AM TANK PERIODIC TEST TYPE TANK PRODUCT LABEL PERIODIC TEST TYPE 1 UNL 1 STANDARD 2 UNL 2 STANDARD 3 PNL STANDARD 4 DIESEL STANDARD I62D00 JUL 27, 2020 9:10 AM TANK LEAK TEST FAIL ALARMS TANK PRODUCT LABEL 1 UNL 1 GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 2 UNL 2 GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 3 PNL GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 4 DIESEL GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED I63100 JUL 27, 2020 9:10 AM TANK LEAK TEST AVERAGING TANK PRODUCT LABEL ANNUAL PERIODIC 1 UNL 1 OFF OFF 2 UNL 2 OFF OFF 3 PNL OFF OFF 4 DIESEL OFF OFF I63000 JUL 27, 2020 9:10 AM IN-TANK LEAK TEST NOTIFY TANK PRODUCT LABEL TANK TEST NOTIFY: 1 UNL 1 OFF 2 UNL 2 OFF 3 PNL OFF 4 DIESEL OFF I63200 JUL 27, 2020 9:10 AM TANK TEST SIPHON BREAK TANK PRODUCT LABEL SIPHON BREAK 1 UNL 1 OFF 2 UNL 2 OFF 3 PNL OFF 4 DIESEL OFF I61000 JUL 27, 2020 9:10 AM TANK DELIVERY DELAY TANK PRODUCT LABEL 1 UNL 1 1 2 UNL 2 1 3 PNL 1 4 DIESEL 1 I63A00 JUL 27, 2020 9:10 AM LOW LEVEL PUMP THRESHOLD FOR SEQUENTIAL LINE MANIFOLD TANK PRODUCT LABEL PUMP THRESHOLD 1 UNL 1 10.00% 2 UNL 2 10.00% 3 PNL 10.00% 4 DIESEL 10.00% I61100 JUL 27, 2020 9:10 AM LEAK TEST METHOD - - - - - - - - - - - - TEST ON DATE : ALL TANK JAN 16, 2006 START TIME : DISABLED TEST RATE :0.20 GAL/HR DURATION : 2 HOURS TST EARLY STOP:DISABLED I61300 JUL 27, 2020 9:10 AM CSLD PROBABLITY OF DETECTION I61400 JUL 27, 2020 9:10 AM CSLD CLIMATE FACTOR I61600 JUL 27, 2020 9:10 AM TANK PRODUCT LABEL CAL UPDATE 1 UNL 1 IMMEDIATE 2 UNL 2 IMMEDIATE 3 PNL IMMEDIATE 4 DIESEL IMMEDIATE I61A00 JUL 27, 2020 9:10 AM IN-TANK LEAK TEST EARLY STOP TANK PRODUCT LABEL TST EARLY STOP: 1 UNL 1 DISABLED 2 UNL 2 DISABLED 3 PNL DISABLED 4 DIESEL DISABLED I61B00 JUL 27, 2020 9:10 AM IN-TANK LEAK GROSS TEST AUTO-CONFIRM I61C00 JUL 27, 2020 9:10 AM CSLD REPORT ONLY I62B00 JUL 27, 2020 9:10 AM TANK LAST ANNUAL TEST TANK PRODUCT LABEL DATE 1 UNL 1 ??? 0, 0 2 UNL 2 ??? 0, 0 3 PNL ??? 0, 0 4 DIESEL ??? 0, 0 I63300 JUL 27, 2020 9:10 AM LEAK TEST REPORT FORMAT: NORMAL I63400 JUL 27, 2020 9:10 AM RECONCILIATION WARNING LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 1 0 2 UNL 2 0 3 PNL 0 4 DIESEL 0 I63500 JUL 27, 2020 9:10 AM RECONCILIATION ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 1 1 2 UNL 2 1 3 PNL 1 4 DIESEL 1 I63900 JUL 27, 2020 9:10 AM ACCU CHART END SHAPE FACTOR TANK PRODUCT LABEL 1 UNL 1 END FACTOR: NONE 2 UNL 2 END FACTOR: NONE 3 PNL END FACTOR: NONE 4 DIESEL END FACTOR: NONE I78000 JUL 27, 2020 9:10 AM I77700 JUL 27, 2020 9:10 AM I77800 JUL 27, 2020 9:10 AM I78C00 JUL 27, 2020 9:10 AM I78300 JUL 27, 2020 9:10 AM I78F00 JUL 27, 2020 9:10 AM I78700 JUL 27, 2020 9:10 AM I70200 JUL 27, 2020 9:10 AM LIQUID LABEL DEVICE LABEL 1 UNL 1 STP 2 UNL 1 ANN 3 DIESEL STP 4 DIESEL ANN 5 REG2 STP 6 REG 2 ANN 7 SUPER STP 8 SUPER ANN 9 DISP 1-2 10 DISP 7-8 11 DISP 5-6 12 DISP 3-4 13 NO.TRANS 14 SO.TRANS 15 16 I70300 JUL 27, 2020 9:10 AM LIQUID TYPE SENSOR LOCATION TYPE 1 UNL 1 STP TRI-STATE (SINGLE FLOAT) 2 UNL 1 ANN TRI-STATE (SINGLE FLOAT) 3 DIESEL STP TRI-STATE (SINGLE FLOAT) 4 DIESEL ANN TRI-STATE (SINGLE FLOAT) 5 REG2 STP TRI-STATE (SINGLE FLOAT) 6 REG 2 ANN TRI-STATE (SINGLE FLOAT) 7 SUPER STP TRI-STATE (SINGLE FLOAT) 8 SUPER ANN TRI-STATE (SINGLE FLOAT) 9 DISP 1-2 TRI-STATE (SINGLE FLOAT) 10 DISP 7-8 TRI-STATE (SINGLE FLOAT) 11 DISP 5-6 TRI-STATE (SINGLE FLOAT) 12 DISP 3-4 TRI-STATE (SINGLE FLOAT) 13 NO.TRANS TRI-STATE (SINGLE FLOAT) 14 SO.TRANS TRI-STATE (SINGLE FLOAT) 15 TRI-STATE (SINGLE FLOAT) 16 TRI-STATE (SINGLE FLOAT) I70400 JUL 27, 2020 9:10 AM LIQUID CATEGORY SENSOR LOCATION CATEGORY 1 UNL 1 STP STP SUMP 2 UNL 1 ANN OTHER SENSORS 3 DIESEL STP STP SUMP 4 DIESEL ANN ANNULAR SPACE 5 REG2 STP STP SUMP 6 REG 2 ANN ANNULAR SPACE 7 SUPER STP STP SUMP 8 SUPER ANN ANNULAR SPACE 9 DISP 1-2 DISPENSER PAN 10 DISP 7-8 DISPENSER PAN 11 DISP 5-6 DISPENSER PAN 12 DISP 3-4 DISPENSER PAN 13 NO.TRANS OTHER SENSORS 14 SO.TRANS OTHER SENSORS 15 OTHER SENSORS 16 OTHER SENSORS I74200 JUL 27, 2020 9:10 AM I74300 JUL 27, 2020 9:10 AM I74400 JUL 27, 2020 9:10 AM I74700 JUL 27, 2020 9:10 AM I74800 JUL 27, 2020 9:10 AM I74900 JUL 27, 2020 9:10 AM I7BC00 JUL 27, 2020 9:10 AM I80200 JUL 27, 2020 9:10 AM I80300 JUL 27, 2020 9:10 AM I80400 JUL 27, 2020 9:10 AM I80700 JUL 27, 2020 9:10 AM RELAY LABEL DEVICE LABEL 1 UNL 1 2 PNL 3 DIESEL 4 OVERFILL ALARM I80900 JUL 27, 2020 9:10 AM RELAY ORIENTATION RELAY DESIGNATION ORIENTATION 1 UNL 1 NORMALLY OPEN 2 PNL NORMALLY OPEN 3 DIESEL NORMALLY CLOSED 4 OVERFILL ALARM NORMALLY OPEN I80B00 JUL 27, 2020 9:10 AM RELAY TANK ASSIGNMENT RELAY DESIGNATION TANK 1 UNL 1 1 2 PNL 3 3 DIESEL 4 4 OVERFILL ALARM NONE I80A00 JUL 27, 2020 9:10 AM RELAY TYPE RELAY DESIGNATION TYPE 1 UNL 1 PUMP CONTROL OUTPUT 2 PNL PUMP CONTROL OUTPUT 3 DIESEL STANDARD 4 OVERFILL ALARM STANDARD I80C00 JUL 27, 2020 9:10 AM I80800 JUL 27, 2020 9:10 AM RELAY SETUP REPORT R 1:UNL 1 TYPE: PUMP CONTROL OUTPUT TANK #: 1 LIQUID SENSOR ALMS L 1:FUEL ALARM L 4:FUEL ALARM L 5:FUEL ALARM L 9:FUEL ALARM L10:FUEL ALARM L11:FUEL ALARM L12:FUEL ALARM L 1:SENSOR OUT ALARM L 3:SENSOR OUT ALARM L 9:SENSOR OUT ALARM L10:SENSOR OUT ALARM L11:SENSOR OUT ALARM L12:SENSOR OUT ALARM L 1:SHORT ALARM L 3:SHORT ALARM L 9:SHORT ALARM L10:SHORT ALARM L11:SHORT ALARM L12:SHORT ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD VP PRES FAIL ISD VP STATUS FAIL ISD HOSE ALARMS ALL:GROSS COLLECT FAIL ALL:DEGRD COLLECT FAIL ALL:FLOW COLLECT FAIL R 2:PNL TYPE: PUMP CONTROL OUTPUT TANK #: 3 LIQUID SENSOR ALMS L 5:FUEL ALARM L 7:FUEL ALARM L 9:FUEL ALARM L10:FUEL ALARM L11:FUEL ALARM L12:FUEL ALARM L 5:SENSOR OUT ALARM L 9:SENSOR OUT ALARM L10:SENSOR OUT ALARM L11:SENSOR OUT ALARM L12:SENSOR OUT ALARM L 5:SHORT ALARM L 9:SHORT ALARM L10:SHORT ALARM L11:SHORT ALARM L12:SHORT ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD VP PRES FAIL ISD VP STATUS FAIL ISD HOSE ALARMS ALL:GROSS COLLECT FAIL ALL:DEGRD COLLECT FAIL ALL:FLOW COLLECT FAIL R 3:DIESEL TYPE: STANDARD NORMALLY CLOSED TANK #: 4 LIQUID SENSOR ALMS L 3:FUEL ALARM L 7:FUEL ALARM L10:FUEL ALARM L12:FUEL ALARM L13:FUEL ALARM L14:FUEL ALARM L 3:SENSOR OUT ALARM L 7:SENSOR OUT ALARM L10:SENSOR OUT ALARM L11:SENSOR OUT ALARM L12:SENSOR OUT ALARM L13:SENSOR OUT ALARM L14:SENSOR OUT ALARM L 3:SHORT ALARM L 7:SHORT ALARM L10:SHORT ALARM L11:SHORT ALARM L12:SHORT ALARM L13:SHORT ALARM L14:SHORT ALARM R 4:OVERFILL ALARM TYPE: STANDARD NORMALLY OPEN TANK #: NONE IN-TANK ALARMS ALL:OVERFILL ALARM ALL:HIGH PRODUCT ALARM ALL:MAX PRODUCT ALARM I79000 JUL 27, 2020 9:11 AM EDIM:1 VR:349634-003-C TD:06.05.11.11.15 I79100 JUL 27, 2020 9:11 AM I72300 JUL 27, 2020 9:11 AM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 SMARTSENSOR ASSIGNMENT DEVICE LABEL CATEGORY 01 UNKNOWN 02 F.M DISP 1-2 AIR FLOW METER 03 F.M DISP 3-4 AIR FLOW METER 04 F.M DISP 5-6 AIR FLOW METER 05 F.M DISP 7-8 AIR FLOW METER 06 V.P. 1-2 VAPOR PRESSURE 07 UNKNOWN 08 VP 1-2 VAPOR PRESSURE 09 UNKNOWN 10 UNKNOWN 11 UNKNOWN 12 UNKNOWN 13 UNKNOWN 14 UNKNOWN 15 UNKNOWN 16 UNKNOWN 17 UNKNOWN 18 UNKNOWN 19 UNKNOWN 20 UNKNOWN 21 UNKNOWN 22 UNKNOWN 23 UNKNOWN 24 UNKNOWN 25 UNKNOWN 26 UNKNOWN 27 UNKNOWN 28 UNKNOWN 29 UNKNOWN 30 UNKNOWN 31 UNKNOWN 32 UNKNOWN 33 UNKNOWN 34 UNKNOWN 35 UNKNOWN 36 UNKNOWN 37 UNKNOWN 38 UNKNOWN 39 UNKNOWN 40 UNKNOWN IV4E00 JUL 27, 2020 9:11 AM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 EVR/ISD SETUP TYPE: VACUUM ASSIST VACUUM ASSIST TYPE: HEALY VAC IV4F00 JUL 27, 2020 9:11 AM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 NOZZLE A/L RANGE A/L RATIO: 0.95 - 1.15 IV4000 JUL 27, 2020 9:11 AM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 VAPOR PROCESSOR TYPE NONE IV4700 JUL 27, 2020 9:11 AM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 ASSESSMENT TIME START TIME: 10:00 AM TIME DELAY MINUTES: 1 IV5200 JUL 27, 2020 9:11 AM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 ACCEPT HIGH ORVR: NO IV4A00 JUL 27, 2020 9:11 AM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 ISD HOSE TABLE HOSE FP FP AFM REL HOSE ID ID LABEL ID ID LABEL 01 01 01 01 UU BLEND3 02 02 02 01 UU BLEND3 03 03 03 02 UU BLEND3 04 04 04 02 UU BLEND3 05 05 05 03 UU BLEND3 06 06 06 03 UU BLEND3 07 07 07 04 UU BLEND3 08 08 08 04 UU BLEND3 IV4B00 JUL 27, 2020 9:11 AM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 PRODUCT/HOSE MAP TABLE FP AFID M1/H1 M2/H2 M3/H3 M4/H4 01 01 02/01 03/01 09/01 xx/xx 02 01 02/02 03/02 09/02 xx/xx 03 02 02/03 03/03 09/03 xx/xx 04 02 02/04 03/04 09/04 xx/xx 05 03 02/05 03/05 09/05 xx/xx 06 03 02/06 03/06 09/06 xx/xx 07 04 02/07 03/07 09/07 xx/xx 08 04 02/08 03/08 09/08 xx/xx IV4900 JUL 27, 2020 9:11 AM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 LABEL TABLE ID LABEL 01 UNASSIGNED 02 BLEND3 03 REGULAR 04 MID GRADE 05 PREMIUM 06 GOLD 07 BRONZE 08 SILVER 09 BLEND2 10 BLEND4 IV1000 JUL 27, 2020 9:11 AM ISD VERSION: 01.04 Jaco 7781 Alarm History Responses Received: I10200 JUL 27, 2020 9:12 AM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 SYSTEM CONFIGURATION SLOT BOARD TYPE POWER ON RESET CURRENT 1 8SMARTSENSOR BD 39583 39513 2 4 PROBE / G.T. 163771 163569 3 INTERSTITIAL BD 202399 202364 4 INTERSTITIAL BD 201784 201366 5 UNUSED 4909535 4888597 6 UNUSED 4906302 4888471 7 UNUSED 4908674 4892819 8 UNUSED 4908401 4891836 9 STP SENSE BOARD 33208 33194 10 UNUSED 4913854 4904667 11 RELAY BOARD 15014 15000 12 UNUSED 4910389 4892336 13 UNUSED 4908709 4887675 14 UNUSED 4908164 4891353 15 UNUSED 4906946 4891019 16 UNUSED 4908185 4887570 COMM 1 RS232 SERIAL BD 15035 15021 COMM 2 RS232 SERIAL BD 15056 15021 COMM 3 ELEC DISP INT. 101700 101716 COMM 4 UNUSED 4908919 4892816 COMM 5 UNUSED 4907597 4890998 COMM 6 UNUSED 4908185 4893924 I90200 JUL 27, 2020 9:12 AM SOFTWARE REVISION LEVEL VERSION 333.02 SOFTWARE# 346333-100-C CREATED - 12.08.10.11.22 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD/APM I11100 JUL 27, 2020 9:12 AM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME T 1 TANK UNL 1 SUDDEN LOSS ALARM CLEAR 7-26-20 2:48AM T 1 TANK UNL 1 SUDDEN LOSS ALARM ALARM 7-26-20 2:25AM L 2 OTHER UNL 1 ANN SENSOR OUT ALARM CLEAR 7-20-20 10:08AM L 8 ANNULAR SUPER ANN SENSOR OUT ALARM CLEAR 7-20-20 10:08AM L 7 STP SUMP SUPER STP SENSOR OUT ALARM CLEAR 7-20-20 10:08AM L 6 ANNULAR REG 2 ANN SENSOR OUT ALARM CLEAR 7-20-20 10:08AM L 4 ANNULAR DIESEL ANN SENSOR OUT ALARM CLEAR 7-20-20 10:08AM L 3 STP SUMP DIESEL STP SENSOR OUT ALARM CLEAR 7-20-20 10:08AM L10 DISP PAN DISP 7-8 SENSOR OUT ALARM CLEAR 7-20-20 10:08AM L 1 STP SUMP UNL 1 STP SENSOR OUT ALARM CLEAR 7-20-20 10:08AM L 5 STP SUMP REG2 STP SENSOR OUT ALARM CLEAR 7-20-20 10:08AM L12 DISP PAN DISP 3-4 SENSOR OUT ALARM CLEAR 7-20-20 10:08AM L11 DISP PAN DISP 5-6 SENSOR OUT ALARM CLEAR 7-20-20 10:08AM L 9 DISP PAN DISP 1-2 SENSOR OUT ALARM CLEAR 7-20-20 10:08AM L12 DISP PAN DISP 3-4 SENSOR OUT ALARM ALARM 7-20-20 10:04AM L11 DISP PAN DISP 5-6 SENSOR OUT ALARM ALARM 7-20-20 10:04AM L10 DISP PAN DISP 7-8 SENSOR OUT ALARM ALARM 7-20-20 10:04AM L 9 DISP PAN DISP 1-2 SENSOR OUT ALARM ALARM 7-20-20 10:04AM L 4 ANNULAR DIESEL ANN SENSOR OUT ALARM ALARM 7-20-20 10:04AM L 3 STP SUMP DIESEL STP SENSOR OUT ALARM ALARM 7-20-20 10:04AM L 2 OTHER UNL 1 ANN SENSOR OUT ALARM ALARM 7-20-20 10:04AM L 8 ANNULAR SUPER ANN SENSOR OUT ALARM ALARM 7-20-20 10:04AM L 7 STP SUMP SUPER STP SENSOR OUT ALARM ALARM 7-20-20 10:04AM L 6 ANNULAR REG 2 ANN SENSOR OUT ALARM ALARM 7-20-20 10:04AM L 5 STP SUMP REG2 STP SENSOR OUT ALARM ALARM 7-20-20 10:04AM L 1 STP SUMP UNL 1 STP SENSOR OUT ALARM ALARM 7-20-20 10:04AM L 4 ANNULAR DIESEL ANN FUEL ALARM CLEAR 7-20-20 9:46AM L 8 ANNULAR SUPER ANN FUEL ALARM CLEAR 7-20-20 9:45AM L 6 ANNULAR REG 2 ANN FUEL ALARM CLEAR 7-20-20 9:44AM L 4 ANNULAR DIESEL ANN FUEL ALARM ALARM 7-20-20 9:43AM L 8 ANNULAR SUPER ANN FUEL ALARM ALARM 7-20-20 9:41AM L 6 ANNULAR REG 2 ANN FUEL ALARM ALARM 7-20-20 9:41AM L 2 OTHER UNL 1 ANN FUEL ALARM CLEAR 7-20-20 9:40AM L 2 OTHER UNL 1 ANN FUEL ALARM ALARM 7-20-20 9:37AM L 9 DISP PAN DISP 1-2 FUEL ALARM CLEAR 7-20-20 9:28AM L 9 DISP PAN DISP 1-2 FUEL ALARM ALARM 7-20-20 9:25AM L11 DISP PAN DISP 5-6 FUEL ALARM CLEAR 7-20-20 9:25AM L11 DISP PAN DISP 5-6 FUEL ALARM ALARM 7-20-20 9:22AM L10 DISP PAN DISP 7-8 FUEL ALARM CLEAR 7-20-20 9:21AM L10 DISP PAN DISP 7-8 FUEL ALARM ALARM 7-20-20 9:18AM L12 DISP PAN DISP 3-4 FUEL ALARM CLEAR 7-20-20 9:17AM L12 DISP PAN DISP 3-4 FUEL ALARM ALARM 7-20-20 9:13AM L 3 STP SUMP DIESEL STP FUEL ALARM CLEAR 7-20-20 9:11AM L 3 STP SUMP DIESEL STP FUEL ALARM ALARM 7-20-20 9:08AM L 7 STP SUMP SUPER STP FUEL ALARM CLEAR 7-20-20 9:08AM L 7 STP SUMP SUPER STP FUEL ALARM ALARM 7-20-20 9:05AM L 5 STP SUMP REG2 STP FUEL ALARM CLEAR 7-20-20 9:04AM L 5 STP SUMP REG2 STP FUEL ALARM ALARM 7-20-20 9:01AM L 1 STP SUMP UNL 1 STP FUEL ALARM CLEAR 7-20-20 8:56AM L 1 STP SUMP UNL 1 STP FUEL ALARM ALARM 7-20-20 8:53AM I11200 JUL 27, 2020 9:13 AM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 NON-PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME h 8 OTHER FP8: BLEND3 DEGRD COLLECT WARN CLEAR 7-07-20 10:17AM h 8 OTHER FP8: BLEND3 DEGRD COLLECT WARN ALARM 7-07-20 10:01AM OTHER ISD GROSS PRES WARN CLEAR 6-30-20 6:29PM OTHER ISD GROSS PRES WARN ALARM 6-29-20 10:01AM T 1 TANK UNL 1 DELIVERY NEEDED CLEAR 6-26-20 5:38PM T 1 TANK UNL 1 DELIVERY NEEDED ALARM 6-26-20 4:57PM SYSTEM PRINTER ERROR CLEAR 6-20-20 7:41PM SYSTEM PRINTER ERROR ALARM 6-20-20 7:41PM SYSTEM PRINTER ERROR CLEAR 6-20-20 7:41PM SYSTEM PAPER OUT CLEAR 6-20-20 7:41PM SYSTEM PRINTER ERROR ALARM 6-20-20 7:41PM SYSTEM PAPER OUT ALARM 6-20-20 7:41PM SYSTEM PRINTER ERROR CLEAR 6-20-20 7:40PM SYSTEM PAPER OUT CLEAR 6-20-20 7:40PM SYSTEM PRINTER ERROR ALARM 6-20-20 7:40PM SYSTEM PAPER OUT ALARM 6-20-20 7:40PM SYSTEM PRINTER ERROR CLEAR 6-20-20 7:40PM SYSTEM PRINTER ERROR ALARM 6-20-20 7:40PM SYSTEM PRINTER ERROR CLEAR 6-20-20 7:40PM SYSTEM PAPER OUT CLEAR 6-20-20 7:40PM SYSTEM PRINTER ERROR ALARM 6-20-20 7:39PM SYSTEM PAPER OUT ALARM 6-20-20 7:39PM h 4 OTHER FP4: BLEND3 DEGRD COLLECT WARN CLEAR 6-01-20 12:13PM h 4 OTHER FP4: BLEND3 GROSS COLLECT WARN CLEAR 6-01-20 12:13PM h 3 OTHER FP3: BLEND3 DEGRD COLLECT WARN CLEAR 6-01-20 12:13PM OTHER ISD GROSS PRES WARN CLEAR 6-01-20 12:13PM h 4 OTHER FP4: BLEND3 GROSS COLLECT WARN ALARM 6-01-20 10:01AM h 3 OTHER FP3: BLEND3 GROSS COLLECT WARN CLEAR 6-01-20 10:00AM h 3 OTHER FP3: BLEND3 GROSS COLLECT WARN ALARM 5-31-20 10:01AM OTHER ISD GROSS PRES WARN ALARM 5-30-20 10:01AM h 3 OTHER FP3: BLEND3 DEGRD COLLECT WARN ALARM 5-30-20 10:01AM h 4 OTHER FP4: BLEND3 DEGRD COLLECT WARN ALARM 5-29-20 10:01AM OTHER ISD SENSOR OUT WARN CLEAR 5-20-20 2:21PM OTHER ISD SENSOR OUT WARN ALARM 5-20-20 10:01AM h 4 OTHER FP4: BLEND3 DEGRD COLLECT WARN CLEAR 5-12-20 10:00AM T 3 TANK PNL DELIVERY NEEDED CLEAR 5-11-20 7:28PM T 3 TANK PNL DELIVERY NEEDED ALARM 5-11-20 1:28PM h 4 OTHER FP4: BLEND3 DEGRD COLLECT WARN ALARM 5-11-20 10:01AM SYSTEM PRINTER ERROR CLEAR 5-03-20 12:35AM SYSTEM PRINTER ERROR ALARM 5-03-20 12:35AM SYSTEM PRINTER ERROR CLEAR 5-03-20 12:35AM SYSTEM PAPER OUT CLEAR 5-03-20 12:35AM SYSTEM PRINTER ERROR ALARM 5-03-20 12:35AM SYSTEM PAPER OUT ALARM 5-03-20 12:35AM SYSTEM PRINTER ERROR CLEAR 5-03-20 12:35AM SYSTEM PAPER OUT CLEAR 5-03-20 12:35AM SYSTEM PRINTER ERROR ALARM 5-03-20 12:32AM SYSTEM PAPER OUT ALARM 5-03-20 12:32AM T 3 TANK PNL DELIVERY NEEDED CLEAR 4-27-20 3:08PM T 3 TANK PNL DELIVERY NEEDED ALARM 4-27-20 10:21AM I20600 JUL 27, 2020 9:13 AM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 TANK ALARM HISTORY TANK 1 UNL 1 OVERFILL ALARM DEC 8, 2019 2:58 PM JUN 28, 2019 11:31 PM JUL 2, 2018 10:31 AM LOW PRODUCT ALARM AUG 16, 2018 7:22 PM AUG 15, 2018 6:27 PM SUDDEN LOSS ALARM JUL 26, 2020 2:25 AM APR 13, 2020 1:05 AM APR 8, 2020 11:29 PM HIGH PRODUCT ALARM JUL 9, 2018 10:37 AM JUL 2, 2018 10:31 AM FEB 26, 2018 1:33 AM INVALID FUEL LEVEL MAR 27, 2020 4:09 PM NOV 14, 2019 9:51 AM NOV 14, 2019 9:46 AM PROBE OUT MAR 27, 2020 3:42 PM NOV 14, 2019 9:49 AM JUL 5, 2019 8:19 PM DELIVERY NEEDED JUN 26, 2020 4:57 PM FEB 27, 2020 6:17 PM FEB 1, 2020 8:19 PM LOW TEMP WARNING JUL 9, 2018 10:38 AM JUL 2, 2018 10:32 AM JUL 11, 2017 10:27 AM TANK 2 UNL 2 HIGH WATER ALARM JAN 25, 2019 5:28 PM JUL 29, 2018 6:07 AM OVERFILL ALARM DEC 10, 2019 11:13 PM AUG 11, 2019 4:03 PM JUN 26, 2019 4:29 AM SUDDEN LOSS ALARM APR 20, 2020 4:57 AM APR 17, 2020 2:10 PM APR 17, 2020 1:49 PM HIGH PRODUCT ALARM JUL 9, 2018 10:39 AM JUL 2, 2018 10:33 AM JUL 11, 2017 10:19 AM INVALID FUEL LEVEL NOV 14, 2019 9:42 AM PROBE OUT APR 17, 2020 2:22 PM APR 13, 2020 10:47 AM MAR 27, 2020 3:53 PM HIGH WATER WARNING NOV 14, 2019 9:54 AM JAN 25, 2019 5:28 PM JUL 29, 2018 6:07 AM DELIVERY NEEDED APR 17, 2020 2:20 PM NOV 14, 2019 9:41 AM LOW TEMP WARNING APR 17, 2020 2:28 PM NOV 14, 2019 10:13 AM JUL 2, 2018 11:06 AM TANK 3 PNL OVERFILL ALARM NOV 21, 2018 2:01 PM JUL 9, 2018 10:41 AM JUL 2, 2018 10:34 AM HIGH PRODUCT ALARM JUL 11, 2017 10:20 AM PROBE OUT NOV 14, 2019 10:12 AM NOV 14, 2019 9:50 AM JUL 9, 2018 9:37 AM DELIVERY NEEDED MAY 11, 2020 1:28 PM APR 27, 2020 10:21 AM DEC 10, 2019 7:53 PM LOW TEMP WARNING JUL 9, 2018 10:42 AM TANK 4 DIESEL OVERFILL ALARM NOV 21, 2018 2:14 PM JUL 9, 2018 10:43 AM JUL 2, 2018 10:35 AM LOW PRODUCT ALARM JUL 2, 2018 9:19 AM HIGH PRODUCT ALARM JUL 11, 2017 10:21 AM PROBE OUT MAR 27, 2020 3:54 PM JUL 9, 2018 9:38 AM DELIVERY NEEDED MAR 27, 2020 3:52 PM NOV 16, 2019 7:34 PM NOV 5, 2019 11:35 PM MAX PRODUCT ALARM JUL 11, 2017 10:21 AM TANK 5 TANK 6 TANK 7 TANK 8 TANK 9 TANK 10 TANK 11 TANK 12 TANK 13 TANK 14 TANK 15 TANK 16 I38200 JUL 27, 2020 9:13 AM I30200 JUL 27, 2020 9:13 AM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 UNL 1 STP JUL 20, 2020 10:04 AM SENSOR OUT ALARM JUL 20, 2020 8:53 AM FUEL ALARM APR 8, 2020 9:54 AM FUEL ALARM 2 UNL 1 ANN JUL 20, 2020 10:04 AM SENSOR OUT ALARM JUL 20, 2020 9:37 AM FUEL ALARM FEB 12, 2020 8:58 PM SENSOR OUT ALARM 3 DIESEL STP JUL 20, 2020 10:04 AM SENSOR OUT ALARM JUL 20, 2020 9:08 AM FUEL ALARM JUL 23, 2019 9:31 AM SENSOR OUT ALARM 4 DIESEL ANN JUL 20, 2020 10:04 AM SENSOR OUT ALARM JUL 20, 2020 9:43 AM FUEL ALARM JUL 23, 2019 9:31 AM SENSOR OUT ALARM 5 REG2 STP JUL 20, 2020 10:04 AM SENSOR OUT ALARM JUL 20, 2020 9:01 AM FUEL ALARM JUN 11, 2020 9:27 AM FUEL ALARM 6 REG 2 ANN JUL 20, 2020 10:04 AM SENSOR OUT ALARM JUL 20, 2020 9:41 AM FUEL ALARM JUL 23, 2019 9:31 AM SENSOR OUT ALARM 7 SUPER STP JUL 20, 2020 10:04 AM SENSOR OUT ALARM JUL 20, 2020 9:05 AM FUEL ALARM JUN 29, 2020 10:34 AM FUEL ALARM 8 SUPER ANN JUL 20, 2020 10:04 AM SENSOR OUT ALARM JUL 20, 2020 9:41 AM FUEL ALARM JUL 23, 2019 9:31 AM SENSOR OUT ALARM 9 DISP 1-2 JUL 20, 2020 10:04 AM SENSOR OUT ALARM JUL 20, 2020 9:25 AM FUEL ALARM JUL 23, 2019 9:31 AM SENSOR OUT ALARM 10 DISP 7-8 JUL 20, 2020 10:04 AM SENSOR OUT ALARM JUL 20, 2020 9:18 AM FUEL ALARM JUL 23, 2019 9:31 AM SENSOR OUT ALARM 11 DISP 5-6 JUL 20, 2020 10:04 AM SENSOR OUT ALARM JUL 20, 2020 9:22 AM FUEL ALARM APR 8, 2020 7:50 PM FUEL ALARM 12 DISP 3-4 JUL 20, 2020 10:04 AM SENSOR OUT ALARM JUL 20, 2020 9:13 AM FUEL ALARM JUL 23, 2019 9:31 AM SENSOR OUT ALARM I31600 JUL 27, 2020 9:13 AM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 SMART SENSOR ALARM HISTORY REPORT SENSOR LOCATION 2 F.M DISP 1-2 3 F.M DISP 3-4 4 F.M DISP 5-6 5 F.M DISP 7-8 8 VP 1-2 I40200 JUL 27, 2020 9:13 AM I40300 JUL 27, 2020 9:13 AM I34200 JUL 27, 2020 9:13 AM I34700 JUL 27, 2020 9:13 AM IV0100 JUL 27, 2020 9:13 AM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 ISD ALARM STATUS REPORT EVR TYPE: VACUUM ASSIST ISD TYPE: 01.04 VAPOR PROCESSOR TYPE: NONE OVERALL STATUS :PASS EVR VAPOR COLLECTION :PASS EVR VAPOR CONTAINMENT :PASS ISD MONITOR UP-TIME :100% EVR/ISD PASS TIME :100% WARNING ALARMS DATE TIME DESCRIPTION READING VALUE 20-07-07 10:01:12 A/L RATIO DEGRADATION FP 8 BLEND3 0.81 20-06-30 10:01:10 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.22 20-06-29 10:01:09 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.22 20-06-01 10:01:45 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.28 20-06-01 10:01:45 A/L RATIO DEGRADATION FP 4 BLEND3 1.97 20-06-01 10:01:45 A/L RATIO GROSS BLOCKAGE FP 4 BLEND3 1.97 20-06-01 10:01:45 A/L RATIO DEGRADATION FP 3 BLEND3 1.93 20-05-31 10:01:27 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 2.92 20-05-31 10:01:27 A/L RATIO DEGRADATION FP 4 BLEND3 1.84 20-05-31 10:01:27 A/L RATIO DEGRADATION FP 3 BLEND3 1.72 FAILURE ALARMS DATE TIME DESCRIPTION READING VALUE 20-06-01 10:01:45 A/L RATIO GROSS BLOCKAGE FP 3 BLEND3 2.36 19-09-23 10:02:15 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 9.05 19-09-06 10:03:01 A/L RATIO DEGRADATION FP 5 BLEND3 0.79 19-05-14 10:01:59 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 10.82 18-08-26 10:01:37 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.64 17-09-24 10:01:36 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 1.83 17-09-04 10:02:42 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 2.23 16-01-06 10:01:09 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.95 12-10-02 10:01:09 A/L RATIO GROSS BLOCKAGE FP 8 BLEND3 BLKD 12-10-01 10:01:10 A/L RATIO GROSS BLOCKAGE FP 8 BLEND3 BLKD SHUTDOWN & MISCELLANEOUS EVENTS DATE TIME DESCRIPTION ACTION/NAME 20-07-21 10:01:26 READINESS ISD:PP EVR:PP ISD & EVR READY 20-07-20 10:04:10 READINESS ISD:PP EVR:NN EVR READINESS PENDING 20-07-20 10:04:10 ISD STARTUP 20-07-20 10:03:53 ISD SHUTDOWN 20-07-07 10:17:25 COLLECTION TEST HH08 GRADE TEST MANUALLY CLEARED 20-07-07 10:17:19 CONTAINMENT GROSS & DEGRD TEST MANUALLY CLEARED 20-06-30 18:29:34 CONTAINMENT GROSS & DEGRD TEST MANUALLY CLEARED 20-06-01 12:13:17 COLLECTION TEST HH04 GRADE TEST MANUALLY CLEARED 20-06-01 12:13:15 COLLECTION TEST HH03 GRADE TEST MANUALLY CLEARED 20-06-01 12:13:11 CONTAINMENT GROSS & DEGRD TEST MANUALLY CLEARED Jaco 7781 Alarm History After Responses Received: I10200 JUL 27, 2020 11:30 AM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 SYSTEM CONFIGURATION SLOT BOARD TYPE POWER ON RESET CURRENT 1 8SMARTSENSOR BD 39583 39628 2 4 PROBE / G.T. 163771 163756 3 INTERSTITIAL BD 202399 202460 4 INTERSTITIAL BD 201784 201889 5 UNUSED 4909535 4898324 6 UNUSED 4906302 4900111 7 UNUSED 4908674 4896137 8 UNUSED 4908401 4898366 9 STP SENSE BOARD 33208 33266 10 UNUSED 4913854 4890537 11 RELAY BOARD 15014 15007 12 UNUSED 4910389 4898253 13 UNUSED 4908709 4894342 14 UNUSED 4908164 4897222 15 UNUSED 4906946 4897096 16 UNUSED 4908185 4892366 COMM 1 RS232 SERIAL BD 15035 15049 COMM 2 RS232 SERIAL BD 15056 15049 COMM 3 ELEC DISP INT. 101700 101560 COMM 4 UNUSED 4908919 4892955 COMM 5 UNUSED 4907597 4893102 COMM 6 UNUSED 4908185 4896087 I90200 JUL 27, 2020 11:30 AM SOFTWARE REVISION LEVEL VERSION 333.02 SOFTWARE# 346333-100-C CREATED - 12.08.10.11.22 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD/APM I11100 JUL 27, 2020 11:30 AM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME L10 DISP PAN DISP 7-8 SENSOR OUT ALARM ALARM 7-27-20 11:29AM L12 DISP PAN DISP 3-4 SENSOR OUT ALARM ALARM 7-27-20 11:29AM L11 DISP PAN DISP 5-6 SENSOR OUT ALARM ALARM 7-27-20 11:29AM L 4 ANNULAR DIESEL ANN SENSOR OUT ALARM ALARM 7-27-20 11:29AM L 3 STP SUMP DIESEL STP SENSOR OUT ALARM ALARM 7-27-20 11:29AM L 9 DISP PAN DISP 1-2 SENSOR OUT ALARM ALARM 7-27-20 11:29AM L 2 OTHER UNL 1 ANN SENSOR OUT ALARM ALARM 7-27-20 11:29AM L 8 ANNULAR SUPER ANN SENSOR OUT ALARM ALARM 7-27-20 11:29AM L 7 STP SUMP SUPER STP SENSOR OUT ALARM ALARM 7-27-20 11:29AM L 6 ANNULAR REG 2 ANN SENSOR OUT ALARM ALARM 7-27-20 11:29AM L 1 STP SUMP UNL 1 STP SENSOR OUT ALARM ALARM 7-27-20 11:29AM L 5 STP SUMP REG2 STP SENSOR OUT ALARM ALARM 7-27-20 11:29AM L11 DISP PAN DISP 5-6 FUEL ALARM CLEAR 7-27-20 10:55AM L11 DISP PAN DISP 5-6 FUEL ALARM ALARM 7-27-20 10:52AM L10 DISP PAN DISP 7-8 FUEL ALARM CLEAR 7-27-20 10:48AM L10 DISP PAN DISP 7-8 FUEL ALARM ALARM 7-27-20 10:45AM L12 DISP PAN DISP 3-4 FUEL ALARM CLEAR 7-27-20 10:45AM T 3 TANK PNL HIGH WATER ALARM CLEAR 7-27-20 10:42AM L12 DISP PAN DISP 3-4 FUEL ALARM ALARM 7-27-20 10:41AM T 1 TANK UNL 1 SUDDEN LOSS ALARM CLEAR 7-27-20 10:41AM T 4 TANK DIESEL OVERFILL ALARM CLEAR 7-27-20 10:38AM T 4 TANK DIESEL OVERFILL ALARM ALARM 7-27-20 10:38AM T 3 TANK PNL OVERFILL ALARM CLEAR 7-27-20 10:37AM T 3 TANK PNL OVERFILL ALARM ALARM 7-27-20 10:37AM T 1 TANK UNL 1 SUDDEN LOSS ALARM ALARM 7-27-20 10:35AM T 3 TANK PNL HIGH WATER ALARM ALARM 7-27-20 10:33AM T 1 TANK UNL 1 MAX PRODUCT ALARM CLEAR 7-27-20 10:33AM T 1 TANK UNL 1 MAX PRODUCT ALARM ALARM 7-27-20 10:33AM L 9 DISP PAN DISP 1-2 FUEL ALARM CLEAR 7-27-20 10:30AM T 4 TANK DIESEL LOW PRODUCT ALARM CLEAR 7-27-20 10:29AM T 4 TANK DIESEL LOW PRODUCT ALARM ALARM 7-27-20 10:28AM L 9 DISP PAN DISP 1-2 FUEL ALARM ALARM 7-27-20 10:26AM L 5 STP SUMP REG2 STP FUEL ALARM CLEAR 7-27-20 10:26AM L 3 STP SUMP DIESEL STP FUEL ALARM CLEAR 7-27-20 10:25AM L 5 STP SUMP REG2 STP FUEL ALARM ALARM 7-27-20 10:22AM L 3 STP SUMP DIESEL STP FUEL ALARM ALARM 7-27-20 10:22AM L 7 STP SUMP SUPER STP FUEL ALARM CLEAR 7-27-20 10:22AM L 1 STP SUMP UNL 1 STP FUEL ALARM CLEAR 7-27-20 10:21AM L 7 STP SUMP SUPER STP FUEL ALARM ALARM 7-27-20 10:19AM L 1 STP SUMP UNL 1 STP FUEL ALARM ALARM 7-27-20 10:18AM L 2 OTHER UNL 1 ANN FUEL ALARM CLEAR 7-27-20 10:14AM L 6 ANNULAR REG 2 ANN FUEL ALARM CLEAR 7-27-20 10:14AM L 8 ANNULAR SUPER ANN FUEL ALARM CLEAR 7-27-20 10:13AM L 4 ANNULAR DIESEL ANN FUEL ALARM CLEAR 7-27-20 10:13AM L 2 OTHER UNL 1 ANN FUEL ALARM ALARM 7-27-20 10:11AM L 6 ANNULAR REG 2 ANN FUEL ALARM ALARM 7-27-20 10:11AM L 8 ANNULAR SUPER ANN FUEL ALARM ALARM 7-27-20 10:10AM L 4 ANNULAR DIESEL ANN FUEL ALARM ALARM 7-27-20 10:09AM T 1 TANK UNL 1 SUDDEN LOSS ALARM CLEAR 7-26-20 2:48AM T 1 TANK UNL 1 SUDDEN LOSS ALARM ALARM 7-26-20 2:25AM I11200 JUL 27, 2020 11:30 AM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 NON-PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME T 3 TANK PNL HIGH WATER WARNING CLEAR 7-27-20 10:42AM T 2 TANK UNL 2 HIGH PRODUCT ALARM CLEAR 7-27-20 10:35AM T 2 TANK UNL 2 HIGH PRODUCT ALARM ALARM 7-27-20 10:35AM T 3 TANK PNL DELIVERY NEEDED CLEAR 7-27-20 10:35AM T 3 TANK PNL HIGH WATER WARNING ALARM 7-27-20 10:33AM T 1 TANK UNL 1 HIGH PRODUCT ALARM CLEAR 7-27-20 10:33AM T 1 TANK UNL 1 HIGH PRODUCT ALARM ALARM 7-27-20 10:33AM T 3 TANK PNL DELIVERY NEEDED ALARM 7-27-20 10:30AM T 4 TANK DIESEL DELIVERY NEEDED CLEAR 7-27-20 10:29AM T 4 TANK DIESEL DELIVERY NEEDED ALARM 7-27-20 10:28AM h 8 OTHER FP8: BLEND3 DEGRD COLLECT WARN CLEAR 7-07-20 10:17AM h 8 OTHER FP8: BLEND3 DEGRD COLLECT WARN ALARM 7-07-20 10:01AM OTHER ISD GROSS PRES WARN CLEAR 6-30-20 6:29PM OTHER ISD GROSS PRES WARN ALARM 6-29-20 10:01AM T 1 TANK UNL 1 DELIVERY NEEDED CLEAR 6-26-20 5:38PM T 1 TANK UNL 1 DELIVERY NEEDED ALARM 6-26-20 4:57PM SYSTEM PRINTER ERROR CLEAR 6-20-20 7:41PM SYSTEM PRINTER ERROR ALARM 6-20-20 7:41PM SYSTEM PRINTER ERROR CLEAR 6-20-20 7:41PM SYSTEM PAPER OUT CLEAR 6-20-20 7:41PM SYSTEM PRINTER ERROR ALARM 6-20-20 7:41PM SYSTEM PAPER OUT ALARM 6-20-20 7:41PM SYSTEM PRINTER ERROR CLEAR 6-20-20 7:40PM SYSTEM PAPER OUT CLEAR 6-20-20 7:40PM SYSTEM PRINTER ERROR ALARM 6-20-20 7:40PM SYSTEM PAPER OUT ALARM 6-20-20 7:40PM SYSTEM PRINTER ERROR CLEAR 6-20-20 7:40PM SYSTEM PRINTER ERROR ALARM 6-20-20 7:40PM SYSTEM PRINTER ERROR CLEAR 6-20-20 7:40PM SYSTEM PAPER OUT CLEAR 6-20-20 7:40PM SYSTEM PRINTER ERROR ALARM 6-20-20 7:39PM SYSTEM PAPER OUT ALARM 6-20-20 7:39PM h 4 OTHER FP4: BLEND3 DEGRD COLLECT WARN CLEAR 6-01-20 12:13PM h 4 OTHER FP4: BLEND3 GROSS COLLECT WARN CLEAR 6-01-20 12:13PM h 3 OTHER FP3: BLEND3 DEGRD COLLECT WARN CLEAR 6-01-20 12:13PM OTHER ISD GROSS PRES WARN CLEAR 6-01-20 12:13PM h 4 OTHER FP4: BLEND3 GROSS COLLECT WARN ALARM 6-01-20 10:01AM h 3 OTHER FP3: BLEND3 GROSS COLLECT WARN CLEAR 6-01-20 10:00AM h 3 OTHER FP3: BLEND3 GROSS COLLECT WARN ALARM 5-31-20 10:01AM OTHER ISD GROSS PRES WARN ALARM 5-30-20 10:01AM h 3 OTHER FP3: BLEND3 DEGRD COLLECT WARN ALARM 5-30-20 10:01AM h 4 OTHER FP4: BLEND3 DEGRD COLLECT WARN ALARM 5-29-20 10:01AM OTHER ISD SENSOR OUT WARN CLEAR 5-20-20 2:21PM OTHER ISD SENSOR OUT WARN ALARM 5-20-20 10:01AM h 4 OTHER FP4: BLEND3 DEGRD COLLECT WARN CLEAR 5-12-20 10:00AM T 3 TANK PNL DELIVERY NEEDED CLEAR 5-11-20 7:28PM T 3 TANK PNL DELIVERY NEEDED ALARM 5-11-20 1:28PM h 4 OTHER FP4: BLEND3 DEGRD COLLECT WARN ALARM 5-11-20 10:01AM SYSTEM PRINTER ERROR CLEAR 5-03-20 12:35AM SYSTEM PRINTER ERROR ALARM 5-03-20 12:35AM I20600 JUL 27, 2020 11:31 AM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 TANK ALARM HISTORY TANK 1 UNL 1 OVERFILL ALARM DEC 8, 2019 2:58 PM JUN 28, 2019 11:31 PM JUL 2, 2018 10:31 AM LOW PRODUCT ALARM AUG 16, 2018 7:22 PM AUG 15, 2018 6:27 PM SUDDEN LOSS ALARM JUL 27, 2020 10:35 AM JUL 26, 2020 2:25 AM APR 13, 2020 1:05 AM HIGH PRODUCT ALARM JUL 27, 2020 10:33 AM JUL 9, 2018 10:37 AM JUL 2, 2018 10:31 AM INVALID FUEL LEVEL MAR 27, 2020 4:09 PM NOV 14, 2019 9:51 AM NOV 14, 2019 9:46 AM PROBE OUT MAR 27, 2020 3:42 PM NOV 14, 2019 9:49 AM JUL 5, 2019 8:19 PM DELIVERY NEEDED JUN 26, 2020 4:57 PM FEB 27, 2020 6:17 PM FEB 1, 2020 8:19 PM MAX PRODUCT ALARM JUL 27, 2020 10:33 AM LOW TEMP WARNING JUL 9, 2018 10:38 AM JUL 2, 2018 10:32 AM JUL 11, 2017 10:27 AM TANK 2 UNL 2 HIGH WATER ALARM JAN 25, 2019 5:28 PM JUL 29, 2018 6:07 AM OVERFILL ALARM DEC 10, 2019 11:13 PM AUG 11, 2019 4:03 PM JUN 26, 2019 4:29 AM SUDDEN LOSS ALARM APR 20, 2020 4:57 AM APR 17, 2020 2:10 PM APR 17, 2020 1:49 PM HIGH PRODUCT ALARM JUL 27, 2020 10:35 AM JUL 9, 2018 10:39 AM JUL 2, 2018 10:33 AM INVALID FUEL LEVEL NOV 14, 2019 9:42 AM PROBE OUT APR 17, 2020 2:22 PM APR 13, 2020 10:47 AM MAR 27, 2020 3:53 PM HIGH WATER WARNING NOV 14, 2019 9:54 AM JAN 25, 2019 5:28 PM JUL 29, 2018 6:07 AM DELIVERY NEEDED APR 17, 2020 2:20 PM NOV 14, 2019 9:41 AM LOW TEMP WARNING APR 17, 2020 2:28 PM NOV 14, 2019 10:13 AM JUL 2, 2018 11:06 AM TANK 3 PNL HIGH WATER ALARM JUL 27, 2020 10:33 AM OVERFILL ALARM JUL 27, 2020 10:37 AM NOV 21, 2018 2:01 PM JUL 9, 2018 10:41 AM HIGH PRODUCT ALARM JUL 11, 2017 10:20 AM PROBE OUT NOV 14, 2019 10:12 AM NOV 14, 2019 9:50 AM JUL 9, 2018 9:37 AM HIGH WATER WARNING JUL 27, 2020 10:33 AM DELIVERY NEEDED JUL 27, 2020 10:30 AM MAY 11, 2020 1:28 PM APR 27, 2020 10:21 AM LOW TEMP WARNING JUL 9, 2018 10:42 AM TANK 4 DIESEL OVERFILL ALARM JUL 27, 2020 10:38 AM NOV 21, 2018 2:14 PM JUL 9, 2018 10:43 AM LOW PRODUCT ALARM JUL 27, 2020 10:28 AM JUL 2, 2018 9:19 AM HIGH PRODUCT ALARM JUL 11, 2017 10:21 AM PROBE OUT MAR 27, 2020 3:54 PM JUL 9, 2018 9:38 AM DELIVERY NEEDED JUL 27, 2020 10:28 AM MAR 27, 2020 3:52 PM NOV 16, 2019 7:34 PM MAX PRODUCT ALARM JUL 11, 2017 10:21 AM TANK 5 TANK 6 TANK 7 TANK 8 TANK 9 TANK 10 TANK 11 TANK 12 TANK 13 TANK 14 TANK 15 TANK 16 I38200 JUL 27, 2020 11:31 AM I30200 JUL 27, 2020 11:31 AM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 UNL 1 STP JUL 27, 2020 11:29 AM SENSOR OUT ALARM JUL 27, 2020 10:18 AM FUEL ALARM JUL 20, 2020 10:04 AM SENSOR OUT ALARM 2 UNL 1 ANN JUL 27, 2020 11:29 AM SENSOR OUT ALARM JUL 27, 2020 10:11 AM FUEL ALARM JUL 20, 2020 10:04 AM SENSOR OUT ALARM 3 DIESEL STP JUL 27, 2020 11:29 AM SENSOR OUT ALARM JUL 27, 2020 10:22 AM FUEL ALARM JUL 20, 2020 10:04 AM SENSOR OUT ALARM 4 DIESEL ANN JUL 27, 2020 11:29 AM SENSOR OUT ALARM JUL 27, 2020 10:09 AM FUEL ALARM JUL 20, 2020 10:04 AM SENSOR OUT ALARM 5 REG2 STP JUL 27, 2020 11:29 AM SENSOR OUT ALARM JUL 27, 2020 10:22 AM FUEL ALARM JUL 20, 2020 10:04 AM SENSOR OUT ALARM 6 REG 2 ANN JUL 27, 2020 11:29 AM SENSOR OUT ALARM JUL 27, 2020 10:11 AM FUEL ALARM JUL 20, 2020 10:04 AM SENSOR OUT ALARM 7 SUPER STP JUL 27, 2020 11:29 AM SENSOR OUT ALARM JUL 27, 2020 10:19 AM FUEL ALARM JUL 20, 2020 10:04 AM SENSOR OUT ALARM 8 SUPER ANN JUL 27, 2020 11:29 AM SENSOR OUT ALARM JUL 27, 2020 10:10 AM FUEL ALARM JUL 20, 2020 10:04 AM SENSOR OUT ALARM 9 DISP 1-2 JUL 27, 2020 11:29 AM SENSOR OUT ALARM JUL 27, 2020 10:26 AM FUEL ALARM JUL 20, 2020 10:04 AM SENSOR OUT ALARM 10 DISP 7-8 JUL 27, 2020 11:29 AM SENSOR OUT ALARM JUL 27, 2020 10:45 AM FUEL ALARM JUL 20, 2020 10:04 AM SENSOR OUT ALARM 11 DISP 5-6 JUL 27, 2020 11:29 AM SENSOR OUT ALARM JUL 27, 2020 10:52 AM FUEL ALARM JUL 20, 2020 10:04 AM SENSOR OUT ALARM 12 DISP 3-4 JUL 27, 2020 11:29 AM SENSOR OUT ALARM JUL 27, 2020 10:41 AM FUEL ALARM JUL 20, 2020 10:04 AM SENSOR OUT ALARM I31600 JUL 27, 2020 11:31 AM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 SMART SENSOR ALARM HISTORY REPORT SENSOR LOCATION 2 F.M DISP 1-2 3 F.M DISP 3-4 4 F.M DISP 5-6 5 F.M DISP 7-8 8 VP 1-2 I40200 JUL 27, 2020 11:31 AM I40300 JUL 27, 2020 11:31 AM I34200 JUL 27, 2020 11:31 AM I34700 JUL 27, 2020 11:31 AM IV0100 JUL 27, 2020 11:31 AM FASTRIP 781 4013 S.H ST BAKERSFIELD CA,93304 ISD ALARM STATUS REPORT EVR TYPE: VACUUM ASSIST ISD TYPE: 01.04 VAPOR PROCESSOR TYPE: NONE OVERALL STATUS :PASS EVR VAPOR COLLECTION :PASS EVR VAPOR CONTAINMENT :PASS ISD MONITOR UP-TIME :100% EVR/ISD PASS TIME :100% WARNING ALARMS DATE TIME DESCRIPTION READING VALUE 20-07-07 10:01:12 A/L RATIO DEGRADATION FP 8 BLEND3 0.81 20-06-30 10:01:10 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.22 20-06-29 10:01:09 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.22 20-06-01 10:01:45 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.28 20-06-01 10:01:45 A/L RATIO DEGRADATION FP 4 BLEND3 1.97 20-06-01 10:01:45 A/L RATIO GROSS BLOCKAGE FP 4 BLEND3 1.97 20-06-01 10:01:45 A/L RATIO DEGRADATION FP 3 BLEND3 1.93 20-05-31 10:01:27 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 2.92 20-05-31 10:01:27 A/L RATIO DEGRADATION FP 4 BLEND3 1.84 20-05-31 10:01:27 A/L RATIO DEGRADATION FP 3 BLEND3 1.72 FAILURE ALARMS DATE TIME DESCRIPTION READING VALUE 20-06-01 10:01:45 A/L RATIO GROSS BLOCKAGE FP 3 BLEND3 2.36 19-09-23 10:02:15 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 9.05 19-09-06 10:03:01 A/L RATIO DEGRADATION FP 5 BLEND3 0.79 19-05-14 10:01:59 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 10.82 18-08-26 10:01:37 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.64 17-09-24 10:01:36 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 1.83 17-09-04 10:02:42 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 2.23 16-01-06 10:01:09 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.95 12-10-02 10:01:09 A/L RATIO GROSS BLOCKAGE FP 8 BLEND3 BLKD 12-10-01 10:01:10 A/L RATIO GROSS BLOCKAGE FP 8 BLEND3 BLKD SHUTDOWN & MISCELLANEOUS EVENTS DATE TIME DESCRIPTION ACTION/NAME 20-07-27 11:28:49 READINESS ISD:PP EVR:NN EVR READINESS PENDING 20-07-27 11:28:49 ISD STARTUP 20-07-27 11:28:35 ISD SHUTDOWN 20-07-21 10:01:26 READINESS ISD:PP EVR:PP ISD & EVR READY 20-07-20 10:04:10 READINESS ISD:PP EVR:NN EVR READINESS PENDING 20-07-20 10:04:10 ISD STARTUP 20-07-20 10:03:53 ISD SHUTDOWN 20-07-07 10:17:25 COLLECTION TEST HH08 GRADE TEST MANUALLY CLEARED 20-07-07 10:17:19 CONTAINMENT GROSS & DEGRD TEST MANUALLY CLEARED 20-06-30 18:29:34 CONTAINMENT GROSS & DEGRD TEST MANUALLY CLEARED &(56 &DOLIRUQLD(QYLURQPHQWDO5HSRUWLQJ6\VWHP,' ,GHQWLILFDWLRQ867 8QGHUJURXQG6WRUDJH7DQN,&& ,QWHUQDWLRQDO&RGH&RXQFLO 81 ZZZXQLGRFVRUJ5HY 81'(5*5281'6725$*(7$1. 63,//&217$,1(57(67,1*5(3257)250 3DJHRI  7\SHRI$FWLRQ,QVWDOODWLRQ7HVW5HSDLU7HVW0RQWK7HVW , )$&,/,7<,1)250$7,21 &(56,''DWHRI6SLOO&RQWDLQHU7HVW %XVLQHVV1DPH(Same as Facility Name or DBA-Doing Business As) %XVLQHVV6LWH$GGUHVV &LW\ =,3&RGH ,, 81'(5*5281'6725$*(7$1.6(59,&(7(&+1,&,$1,1)250$7,21 1DPHRI8676HUYLFH7HFKQLFLDQ3HUIRUPLQJWKH7HVW(Print as shown on the ICC Certification.) 3KRQH &RQWUDFWRU7DQN7HVWHU/LFHQVH ,&&&HUWLILFDWLRQ ,&&&HUWLILFDWLRQ([SLUDWLRQ'DWH 6SLOO&RQWDLQHU7HVWLQJ7UDLQLQJDQG&HUWLILFDWLRQV(List applicable certifications.) ,,, 63,//&217$,1(57(67,1*,1)250$7,21 7HVW0HWKRG8VHG0DQXIDFWXUHU*XLGHOLQHV(Specify) ,QGXVWU\&RGHRU(QJLQHHULQJ6WDQGDUG (Specify) (QJLQHHUHG0HWKRG(Specify) Attach the testing procedures and all documentation required to determine the results.RI$WWDFKHG3DJHV 7$1.,'(By tank number, stored product, etc.) 6SLOO&RQWDLQHU0DQXIDFWXUHU 0HWKRGRI&DWKRGLF3URWHFWLRQ1RQ0HWDOOLF1RQ0HWDOOLF1RQ0HWDOOLF1RQ0HWDOOLF ,VRODWLRQ,VRODWLRQ,VRODWLRQ,VRODWLRQ 2WKHU(Specify in V.)2WKHU(Specify in V.)2WKHU(Specify in V.)2WKHU(Specify in V.) ,QVLGH'LDPHWHURI6SLOO&RQWDLQHU(Inches) 'HSWKRI6SLOO&RQWDLQHU(Inches) 'RHVWKHVSLOOFRQWDLQHUKDYHDJDOORQFDSDFLW\"<HV1R<HV1R<HV1R<HV1R 0HWKRGWR.HHS6SLOO&RQWDLQHU(PSW\'UDLQ9DOYH'UDLQ9DOYH'UDLQ9DOYH'UDLQ9DOYH 2QVLWH3XPS2QVLWH3XPS2QVLWH3XPS2QVLWH3XPS 2WKHU(Specify in V.)2WKHU(Specify in V.)2WKHU(Specify in V.)2WKHU(Specify in V.) ,9 6800$5<2)7(67,1*5(68/76 6SLOO&RQWDLQHU7HVW5HVXOWV3DVV)DLO3DVV)DLO3DVV)DLO3DVV)DLO 9 &200(176 Any items marked “Fail” above must be explained in this section. Any additional comments may also be provided here. 9, &(57,),&$7,21%<8676(59,&(7(&+1,&,$1&21'8&7,1*7+,67(67,1* ,KHUHE\FHUWLI\WKDWWKHVSLOOFRQWDLQHUVZHUHWHVWHGLQDFFRUGDQFHZLWK&DOLIRUQLD&RGHRI5HJXODWLRQV7LWOH'LYLVLRQ &KDSWHU6HFWLRQDQGDOOWKHLQIRUPDWLRQFRQWDLQHGKHUHLQLVDFFXUDWH 8676HUYLFH7HFKQLFLDQ6LJQDWXUH If the facility has more components than this form accommodates, additional copies of this page may be attached. Bakersfield 93304 804904 8485827 9/16/2020 OPW 0148613 Exp 8/19/2020 PEI 1200 0 T1 87-1 OPW 11.00” 12.00” T2 87-2 OPW 11.00” 12.00” T3 91 OPW 11.00” 12.00” T4 DSL OPW 11.00” 12.00” Replaced bellows and drain valve on 87-2 bucket. Aaron Perrigo (800) 339-9930 10159161 7/27/2020 Jaco #7781 Fastrip #22 (South) 4013 S "H" St