Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
2929 E BRUNDAGE OPI SPILL BUCKET 2020
Testing and Inspection Certificate Tanknology Inc. 11000 North MoPac Expressway, Suite 500, Austin, TX 78759 800-800-4633 www.tanknology.com Page 1 of 1 Test Date 7/1/2020 Tanknology WO#SC1-3447816 Test Purpose COMPLIANCE Customer PO# Customer Location PENSKE TRUCK LEASING P.O. BOX 7635 READING, PA 19603 PENSKE CA-094 (CA-094/0198-10) 2929 E. BRUNDAGE BAKERSFIELD, CA 93307 Attn: BRIAN YAZEMBOSKI Attn: Jorge Or David (610) 603-8450 (661) 322-3146 Test / Inspection Description Item Tested Date Tested Result Line Leak Detector (3 GPH) Tank T1 Line 1 Diesel 7/1/2020 Pass Impact Valve Inspection See test report for details 7/1/2020 Pass Leak Detection Monitoring System Inspection See test report for details 7/1/2020 Fail California Spill Container Report Diesel SB 1 - Fill - Direct 7/1/2020 Fail Spill Containment / Bucket Diesel SB 1 - Fill - Direct 7/1/2020 Fail CA Overfill Prevention Equipment Inspection Report DEF 2 Diesel Exhaust Fluid 7/1/2020 Pass CA Overfill Prevention Equipment Inspection Report Diesel 1 Diesel 7/1/2020 Pass E-Stop Inspection See test report for details 7/1/2020 Pass Tanknology Representative: Mark Lindsey Technician: Edwin Pineda Telephone: (800) 666-2176 Technician Certification: (See forms) LDT 5000 Field Test Apparatus Line Leak Detector Test Page 1 of 1 Work Order:3447816 Date:7/1/2020 Site Name / ID:PENSKE CA-094 / CA-094/0198-10 Address:2929 E. BRUNDAGE City:BAKERSFIELD State:CA Zip:93307 Tank ID Product Product Line Tested From Existing/New Mechanical/Electronic Manufacturer/Model Serial No. Pump Operating Pressure (psi) Calibrated Leak (ml/min) Calibrated Leak (gph) Holding PSI *N/A for Electronic LD's Resiliency (ml) *N/A for Electronic LD's Metering PSI *N/A for Electronic LD's Opening Time (sec) *N/A for Electronic LD's Test Results T1 Diesel 1 1 Existing Mechanical Red Jacket FX1DV 4741 41.00 189.0 3.00 20.00 140.00 12 10 Pass Technician Comments: Technician Name:Edwin Pineda Certification #: Technician Signature:Expire Date: Environmental Compliance for Petroleum Systems © 2020 Tanknology Inc., Austin, TX. All rights reserved. tanknology.com Impact Valve Inspection Impact Valve Operational Inspection Work Order:3447816 Date:7/1/2020 Site Name/ID:PENSKE CA-094 Address:2929 E. BRUNDAGE City:BAKERSFIELD State:CA Zip:93307 How Inspected: Line Test NFPA 30A PEI RP1200 Other Dispenser Number Grade Secure Mount? Valve Lock?Pass/ Fail Comments 1/2 40 Pass Fail Not Tested 1 Sat/ 40 Pass Fail Not Tested 2 Sat/ 40 Pass Fail Not Tested Technician Comments: Technician Name:Edwin Pineda Signature: Environmental Compliance for Petroleum Systems ©2020 Tanknology Inc., Austin, TX. All rights reserved. tanknology.com UNDERGROUND STORAGE TANK MONITORING SYSTEM CERTIFICATION FORM (Page 1 of 6) This form must be used to document testing and servicing of underground storage tank (UST) monitoring equipment. A copy of this form must be provided to the UST owner or operator. The owner or operator must submit a copy of this form to the local agency regulating the USTs within 30 days of the date of the monitoring system certification. I. FACILITY INFORMATION CERS ID 10117291 Date of Monitoring System Certification 7/1/2020 Business Name (Same as Facility Name or DBA-Doing Business As.) PENSKE CA-094 Building # Business Site Address 2929 E. BRUNDAGE City: BAKERSFIELD Zip: 93307 II. UNDERGROUND STORAGE TANK SERVICE TECHNICIAN INFORMATION Name of Company Performing the Certification TANKNOLOGY INC. Phone # (800) 800-4633 Ext. Mailing Address 11000 N. Mopac Expressway #500, Austin, TX 78759 Name of UST Service Technician Performing the Certification (Print as shown on the ICC Certification.) Edwin Pineda Contractor/Tank Tester License # Class A General Engineering 743160 ICC Certification # 8373052 ICC Certification Expiration Date 6/17/2021 Monitoring System Training and Certifications (List all applicable certifications.) Expiration Date Tanknology Certification Level III ATG Operability Training Certification Exam 63535 06/24/2021 ICC CA UST Service Technician 8373052 06/17/2021 Veeder Root Maintenance Key B37453 12/11/2020 OPW EVR Phase 1 100776 01/05/2021 III. RESULTS OF TESTING/SERVICING Indicate and attach the following reports if the monitoring equipment is capable of generating either. Monitoring System Set-up Alarm History Report Y N NA Was any monitoring equipment replaced? (If "Yes,"identify the specific devices replaced and list the manufacturer and model for all replacement parts in section IV below.) Was damage, debris, or liquid found inside any secondary containment systems? (If "Yes," describe what was found in section IV below.) Is all monitoring equipment operational per manufacturer's specifications? (If "No," describe why in section IV below.) IV. COMMENTS If directed to use this section, describe how and when the issues were or will be corrected. Found fuel/water in fill sump also Spill bucket failed due to bucket joint was leaking also L14 vr 304 sensor for UDC 3 Annular was not working also S2 vacuum sensor for DEF ALL LINES does not have vacuum,Site will maintenance for repairs.Fuel/water was removed from fill sump. V. CERTIFICATION BY UST SERVICE TECHNICIAN CONDUCTING THIS TESTING I hereby certify that the equipment identified in this document was inspected/serviced in accordance with California Code of Regulations, title 23, division 3, chapter 16, section 2638 and all information contained herein is true and accurate. Attached to this certification is information (e.g., manufacturers' checklists, monitoring system set-up, alarm history report, etc.) necessary to verify that this information and the site plan showing the layout of UST system is complete and accurate. UST Service Technician Signature CERS=California Environmental Reporting System, ID=Identification, UST=Underground storage tank, ICC=International Code Council UNDERGROUND STORAGE TANK MONITORING SYSTEM CERTIFICATION FORM (Page 2 of 6) VI. INVENTORY OF EQUIPMENT CERTIFIED A separate Monitoring System Certification Form must be prepared for each monitoring system control panel. Make of Monitoring System Control Panel Veeder Root Model of Monitoring System Control Panel TLS-350 Software Version Installed 334.01 Check the appropriate boxes to indicate specific equipment inspected/serviced. Monitoring Device Used Device Model # Tank ID: Diesel Diesel (By tank number, stored product, etc.) In-tank Gauging (SW Tank)846390-110 Annular Space or Vault Sensor 794380-301 VPH Sensor Product Piping Mechanical LLD FX1DV Electronic LLD VPH Sensor (Piping)857280-100 Sump Sensor 794380-208 VPH Sensor (Sump)857280-304 Fill Piping VPH Sensor (Piping)857280-100 Sump Sensor 794380-208 VPH Sensor (Sump)857280-304 Vent Piping VPH Sensor (Piping)857280-100 Sump Sensor 794380-208 VPH Sensor (Sump)857280-304 Vapor Recovery Piping VPH Sensor (Piping) Sump Sensor VPH Sensor (Sump) Monitoring Device Used Device Model # Tank ID: DEF Other (By tank number, stored product, etc.) In-tank Gauging (SW Tank)164-405 Annular Space or Vault Sensor 794390-409 VPH Sensor Product Piping Mechanical LLD Electronic LLD VPH Sensor (Piping)857280-304 Sump Sensor 794380-208 VPH Sensor (Sump)857280-304 Fill Piping VPH Sensor (Piping) Sump Sensor VPH Sensor (Sump) Vent Piping VPH Sensor (Piping) Sump Sensor VPH Sensor (Sump) Vapor Recovery Piping VPH Sensor (Piping) Sump Sensor VPH Sensor (Sump) Monitoring Device Used Device Model # Tank ID: (By tank number, stored product, etc.) In-tank Gauging (SW Tank) Annular Space or Vault Sensor VPH Sensor Product Piping Mechanical LLD Electronic LLD VPH Sensor (Piping) Sump Sensor VPH Sensor (Sump) Fill Piping VPH Sensor (Piping) Sump Sensor VPH Sensor (Sump) Vent Piping VPH Sensor (Piping) Sump Sensor VPH Sensor (Sump) Vapor Recovery Piping VPH Sensor (Piping) Sump Sensor VPH Sensor (Sump) Monitoring Device Used Device Model # Tank ID: (By tank number, stored product, etc.) In-tank Gauging (SW Tank) Annular Space or Vault Sensor VPH Sensor Product Piping Mechanical LLD Electronic LLD VPH Sensor (Piping) Sump Sensor VPH Sensor (Sump) Fill Piping VPH Sensor (Piping) Sump Sensor VPH Sensor (Sump) Vent Piping VPH Sensor (Piping) Sump Sensor VPH Sensor (Sump) Vapor Recovery Piping VPH Sensor (Piping) Sump Sensor VPH Sensor (Sump) CERS=California Environmental Reporting System, ID=Identification, UST=Underground storage tank, ICC=International Code Council UNDERGROUND STORAGE TANK MONITORING SYSTEM CERTIFICATION FORM (Page 3 of 6) Monitoring Device Used Device Model #Monitoring Device Used Device Model # Vent/Transition Sump ID: Vent sump Vent/Transition Sump ID: Sump Sensor 794380-208 Sump Sensor VPH Sensor 857280-304 VPH Sensor UDC ID: 1/2 Electronic Sensor 794380-208 Mechanical Device VPH Sensor 846391-304 UDC ID: 1 Sat Electronic Sensor 794380-208 Mechanical Device VPH Sensor 846391-304 UDC ID: 2 Sat Electronic Sensor 794380-208 Mechanical Device VPH Sensor 846391-304 UDC ID: Electronic Sensor Mechanical Device VPH Sensor UDC ID: Electronic Sensor Mechanical Device VPH Sensor UDC ID: Electronic Sensor Mechanical Device VPH Sensor UDC ID: Electronic Sensor Mechanical Device VPH Sensor UDC ID: Electronic Sensor Mechanical Device VPH Sensor Other Monitored Component ID: Other Monitored Component ID: Other(Specify in section VII) Other(Specify in section VII) Other Monitored Component ID: Other Monitored Component ID: Other(Specify in section VII) Other(Specify in section VII) Other Monitored Component ID: Other Monitored Component ID: Other(Specify in section VII) Other(Specify in section VII) Include information for every underground storage tank component monitored by this monitoring system control panel. If the monitoring system control panel monitors more components than this form accommodates, additoinal copies of these pages may be attached. VII. COMMENTS Use this section to provide any additional comments about the inventory of the equipment certified. CERS=California Environmental Reporting System, ID=Identification, UST=Underground storage tank, ICC=International Code Council UNDERGROUND STORAGE TANK MONITORING SYSTEM CERTIFICATION FORM (Page 4 of 6) VIII. MONITORING SYSTEM AND PROGRAMMING This section must be completed if a monitoring panel is used to perform leak detection monitoring.Y N NA Are the visual and audible alarms operational? Were all sensors visually inspected for kinks and breaks in the cables and for residual buildup to ensure that floats move freely, functionally tested, and confirmed operational? Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will not interfere with their proper operation? Was monitoring system set-up reviewed to ensure proper settings? Was the monitoring panel's backup battery visually inspected, functionally tested, and confirmed operational? Does the flow of fuel stop at the dispenser if a leak is detected in the under-dispenser containment? Does the turbine automatically shut down if the piping secondary containment monitoring system fails to operate or is electrically disconnected? Does the turbine automatically shut down if the piping secondary containment monitoring system detects a leak? Which sensors initiate positive shut down? (Check all that apply.) Sump Under-dispenser containment If alarms are relayed to a remote monitoring station, is all communications equipment (e.g. modem) operational? For any answer of "N" above, describe in section IX how and when these deficiencies were or will be corrected. IX. COMMENTS Use this section to provide any additional comments about the inventory of the equipment certified. X. IN-TANK GAUGING TESTING Check this box if tank gauging is used only for inventory control. (Do not complete this section.) Check this box if NO tank gauging equipment is installed. (Do not complete this section.) This section must be completed if in-tank gauging is used to perform leak detection monitoring. Y N NA Has all input wiring been inspected for kinks and breaks in the cables and for proper entry and termination, including testing for ground faults? Were all in-tank gauging probes visually inspected for damage and residue buildup to ensure that floats move freely, functionally tested, and confirmed operational? Was accuracy of system's product level readings tested? Was accuracy of system's water level readings tested? Were all probes reinstalled properly? Were all items on the equipment manufacturer's maintenance checklist completed? For any answer of "N" above, describe in section XI how and when these deficiencies were or will be corrected. XI. COMMENTS Use this section to provide any additional comments about the inventory of the equipment certified. Y = Yes, N = No, NA = Not Applicable UNDERGROUND STORAGE TANK MONITORING SYSTEM CERTIFICATION FORM (Page 5 of 6) XVI. LINE LEAK DETECTOR TESTING Check this box if line leak detectors (LLD) are NOT installed. (Do not complete this section.) This section must be completed if LLDs are installed.Y N NA Was a leak simulated to verify LLD performance? (Check all that apply.) Simulated leak rate verified: 3 GPH 1.1 GPH 0.2 GPH Was the testing apparatus properly calibrated? For emergency generator tank systems, does the LLD create an audible and visual alarm when a leak is detected? For mechanical LLDs, does the LLD restrict the flow through the pipe when a leak is detected? For electronic LLDs, does the turbine automatically shut off when a leak is detected? For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system is disabled or disconnected? For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system malfunctions or fails a test? For electronic LLDs, have all accessible wiring connections been visually inspected for kinks and breaks? Were all items on the equipment manufacturer's maintenance checklist completed? Were all LLDs confirmed operational within regulatory requirements? For any answer of "N" above, describe in section XIII how and when these issues were or will be corrected. XIII. COMMENTS XIV. VACUUM / PRESSURE/ HYDROSTATIC MONITORING EQUIPMENT TESTING Check this box if VPH monitoring is NOT used. (Do not complete this section.) This section must be completed if VPH monitoring is used to perform leak detection monitoring. System Type (Mark all that apply.) Vacuum Pressure Hydrostatic Sensor ID Component(s) Monitored by this Sensor Sensor Functionality Test Interstitial Communication Test S 1 DIESEL ALL LINES Pass Fail Pass Fail S 2 DEF ALL LINES Pass Fail Pass Fail Pass Fail Pass Fail Pass Fail Pass Fail Pass Fail Pass Fail Pass Fail Pass Fail Pass Fail Pass Fail Pass Fail Pass Fail Pass Fail Pass Fail Pass Fail Pass Fail Pass Fail Pass Fail Pass Fail Pass Fail How was interstitial communication verified? Simulated leak at far ends of the interstitial space. Other (Describe the method in section XV below.) Visual Inspection Gauge Was the vacuum or pressure restored to operating levels in all interstitial spaces? Yes No (Describe the reason in section XV below.) For any answer of "N" above, describe in section XIII how and when these issues were or will be corrected. XV. COMMENTS S1 SENSOR IS WORKING PROPERLY, S2 LIQUID SENSOR IS WORKING BUT VACUMM SENSOR IS NOT WORKING AND IS NOT HOLDING VACUUM. GPH = Gallons per hour, Y = Yes, N = No, NA = Not applicable, VPH = Vacuum/Pressure/Hydrostatic, ID = Identification UNDERGROUND STORAGE TANK MONITORING SYSTEM CERTIFICATION FORM (Page 6 of 6) XVI. MONITORING SITE PLAN Date site map was prepared: If you already have a site plan that shows all required information, you may include it, rather than this page, with your Monitoring System Certification Form. The site plan must show the general layout of tanks and piping and clearly identify locations of the following equipment, if installed: 1) monitoring system control panels; 2) in-tank liquid level probes (if used for leak detection); 3) devices monitoring tank annular spaces or vault; 4) devices monitoring product piping; 5) devices monitoring fill piping; 6) devices monitoring vent piping; 7) devices monitoring vapor recovery piping; 8) devices monitoring vent/transition sumps; 9) devices monitoring under-dispenser containment; 10) line leak detectors; and 11) devices monitoring any other secondary containment areas. UNDERGROUND STORAGE TANK SPILL CONTAINER TESTING REPORT FORM (Page 1 of 1) Type of Action Installation Test Repair Test 12 Month Test I. FACILITY INFORMATION CERS ID 10117291 Date of Spill Container Test: 7/1/2020 Business Name (Same as Facility Name or DBA-Doing Business As.) PENSKE CA-094 Business Site Address 2929 E. BRUNDAGE City: BAKERSFIELD Zip: 93307 II. UNDERGROUND STORAGE TANK SERVICE TECHNICIAN INFORMATION Name of UST Service Technician Performing the Test (Print as shown on the ICC Certification.) Edwin Pineda Phone # (800) 800-4633 Contractor/Tank Tester License # Class A General Engineering 743160 ICC Certification # 8373052 ICC Certification Expiration Date 6/17/2021 Spill Container Testing Training and Certifications (List applicable certifications.) ICC - CA UST Service Technician 8373052 06/17/2021 OPW - EVR Phase 1 100776 01/05/2021 III. SPILL CONTAINER TESTING INFORMATION Test Method Used: Manufacturer Guidelines: (Specify) Industry Code or Engineering Standard: (Specify) PEI RP 1200 Engineered Method: (Specify) Attach the testing procedures and all documentation required to determine the results. # of Attached Pages 2 Tank ID: (By tank number, stored product, etc.) Spill Container Manufacturer: Method of Cathodic Protection Inside Diameter of Spill Container: (Inches) Depth of Spill Container: (Inches) Does the spill container have a 5 gallon capacity? Method to Keep Spill Container Empty IV. Spill Container Test Results Fill T1 Diesel OPW Non-Metallic Isolation Other (Specify in section V) 12 16 Yes No Drain Valve Onsite Pump Other (Specify in section V) Non-Metallic Isolation Other (Specify in section V) Yes No Drain Valve Onsite Pump Other (Specify in section V) Non-Metallic Isolation Other (Specify in section V) Yes No Drain Valve Onsite Pump Other (Specify in section V) Non-Metallic Isolation Other (Specify in section V) Yes No Drain Valve Onsite Pump Other (Specify in section V) SUMMARY OF TESTING RESULTS Pass Fail Pass Fail Pass Fail Pass Fail V. COMMENTS All items marked failed above must be explained in this section. Any additional comments may also be provided here. Spill bucket failed due to bucket joint was leaking. VI. CERTIFICATION BY UST SERVICE TECHNICIAN CONDUCTING THIS I hereby certify that the spill containers were tested in accordance with California Code of Regulations, title 23, division 3, chapter 16, section 2637.1 and all the information contained herein is accurate. UST Service Technician Signature If the facility has more components than this form accommodates, additional copies of this page may be attached. CERS=California Environmental Reporting System, ID=Identification, UST=Underground storage tank, ICC=International Code Council SWRCB, January 2006 Spill Bucket Testing Report Form This form is intended for use by contractors performing annual testing of UST spill containment structures. The completed form and printouts from tests (if applicable), should be provided to the facility owner/operator for submittal to the local regulatory agency. 1. FACILITY INFORMATION Facility Name: PENSKE CA-094 Date of Testing: 7/1/2020 Facility Address: 2929 E. BRUNDAGE , BAKERSFIELD, CA 93307 Facility Contact: Jorge Or David Phone: 661-322-3146 Date Local Agency Was Notified of Testing: Name of Local Agency Inspector (if present during testing): 2. TESTING CONTRACTOR INFORMATION Company Name: TANKNOLOGY INC. Technician Conducting Test: Edwin Pineda Credentials1: CSLB Contractor ICC Service Tech. SWRCB Tank Tester Other (Specify) License Number(s): A-743160- UT 8373052 3. SPILL BUCKET TESTING INFORMATION Test Method Used By: Hydrostatic Vacuum Other Test Equipment Used: LAKE TEST Equipment Resolution: 0.0625 in. Identify Spill Bucket (By Tank Number, Stored Product, etc.) Bucket Installation Type: Bucket Diameter: Bucket Depth: Wait time between applying vacuum/water and start of test Test Start Time (TI): Initial Reading (RI): Test End Time(TF): Final Reading (RF): Test Duration(TF–TI): Change in Reading (RF–RI) : Pass/Fail Threshold or Criteria: Test Result: Spill Box # Tank T1 Diesel - Fill 1 - Direct - Grade level Direct Bury Contained in Sump 12.00 16.00 5 min 09:15:00 16.00 in. H20 09:20:00 14.00 in. H20 5 min -2.00 in. H20 +/- 0.20 Fail Spill Box # Direct Bury Contained in Sump min +/- Spill Box # Direct Bury Contained in Sump min +/- Spill Box # Direct Bury Contained in Sump min +/- Comments - (include information on repairs made prior to testing, and recommended follow-up for failed tests) CERTIFICATION OF TECHNICIAN RESPONSIBLE FOR CONDUCTING THIS TESTING I hereby certify that all the information contained in this report is true, accurate, and in full compliance with legal requirements. Technician's Signature:Date:7/1/2020 1State laws and regulations do not currently require testing to be performed by a qualified contractor. However, local requirements may be more stringent. WO: 3447816 Spill bucket failed due to bucket joint is leaking. UNDERGROUND STORAGE TANK OVERFILL PREVENTION EQUIPMENT INSPECTION REPORT FORM (Page 1 of 1) Type of Action Installation Test Repair Test 36 Month Test I. FACILITY INFORMATION CERS ID 10117291 Date of Overfill Prevention Equipment Inspection: 7/1/2020 Business Name (Same as Facility Name or DBA-Doing Business As.) PENSKE CA-094 Business Site Address 2929 E. BRUNDAGE City: BAKERSFIELD Zip: 93307 II. UNDERGROUND STORAGE TANK SERVICE TECHNICIAN INFORMATION Name of UST Service Technician Performing the Test (Print as shown on the ICC Certification.) Edwin Pineda Phone # (800) 800-4633 Contractor/Tank Tester License # Class A General Engineering 743160 ICC Certification # 8373052 ICC Certification Expiration Date 6/17/2021 Spill Container Testing Training and Certifications (List applicable certifications.) Veeder Root - GVR Technician Safety Course B37453 10/19/2019 ICC - CA UST Service Technician 8373052 06/17/2021 III. OVERFILL PREVENTION EQUIPMENT INSPECTION INFORMATION Test Method Used: Manufacturer Guidelines (Specify) Veeder Root Industry Code or Engineering Standard (Specify) PEI RP 1200 Engineered Method (Specify) Attach the testing procedures and all documentation required to determine the results. # of Attached Pages: 2 Tank ID: (By tank number, stored product, etc.) What is the tank inside diameter? (Inches) Is the fill piping secondarily contained? Is the vent piping secondarily contained? Overfill Prevention Equipment Manufacturer(s) What is the overfill prevention equipment response when activated? (Check all that apply.) Are flow restrictors installed on vent piping? At what level in the tank is the overfill prevention set to activate? (Inches from bottom of tank.) What is the percent capacity of the tank at which the overfill prevention equipment activates? Is the overfill prevention in proper operating condition to respond when the substance reaches the appropriate level? IV. Overfill Prevention Inspection Results Diesel 119.63 in. Yes No Yes No Veeder Root other Shuts Off Flow Restrict Flow A/V Alarm Yes No 100.00" 89.9% Yes No (Specify in section V) DEF 71.63 in. Yes No Yes No Unknown other Shuts Off Flow Restrict Flow A/V Alarm Yes No 59.875" 89.8% Yes No (Specify in section V) Yes No Yes No Shuts Off Flow Restrict Flow A/V Alarm Yes No Yes No (Specify in section V) Yes No Yes No Shuts Off Flow Restrict Flow A/V Alarm Yes No Yes No (Specify in section V) SUMMARY OF TESTING RESULTS Pass Fail Pass Fail Pass Fail Pass Fail V. COMMENTS All items marked failed above must be explained in this section. Any additional comments may also be provided here. VI. CERTIFICATION BY UST SERVICE TECHNICIAN CONDUCTING THIS I hereby certify that the spill containers were tested in accordance with California Code of Regulations, title 23, division 3, chapter 16, section 2637.1 and all the information contained herein is accurate. UST Service Technician Signature If the facility has more components than this form accommodates, additional copies of this page may be attached. CERS=California Environmental Reporting System, ID=Identification, UST=Underground storage tank, ICC=International Code Council Emergency Stop (E-Stop / ESO) Periodic Inspection Facility Information Technician Information Site #: PENSKE CA-094 CA-094/0198-10 Date: 7/1/2020 Address: 2929 E. BRUNDAGE Name: Edwin Pineda City / State: BAKERSFIELD CA Technician Signature: The objective of this test is to provide assurance that the when the E-Stop switch is activated, all the fueling system circuits (turbines, and dispensers) are de-energized, and remain de-energized until they are re-set manually). The test procedures and guidelines shall be in accordance with the E-Stop Testing Process. SITE DATA 1 Number of E-Stop switches INSIDE of the building: 1 2 Number of E-Stop switches OUTSIDE of the building: 2 PERFORMANCE DATA Yes No NA 3 You have added or confirmed that all E-Stop locations are on the Site Diagram 4 Do all E-Stops shutdown power to ALL DISPENSERS 5 Do all E-Stops shutdown power to ALL STP's 6 Are ALL E-Stops clearly Labeled 7 Are the TURBINE BREAKERS clearly identified / labeled POST TEST 8 All equipment secured and any access ports, lids, enclosures are closed. 9 All safety barricades and test equipment has been properly removed 10 E-Stop was reset and all dispensing functions are normal E-Stop Inspection Results 11 PASS FAIL INCONCLUSIVE Comments (Clearly describe any deficiencies found) WO: 3447816 Site Diagram (This site diagram is for reference only and is not drawn to scale) Work Order:3447816 Site ID / Name:CA-094/0198-10 / PENSKE CA-094 Address:2929 E. BRUNDAGE City:BAKERSFIELD State:CA Zip:93307 W.O.# SC1-3447816 Ovf W.O.# SC1-3447816 Vr sticker W.O.# SC1-3447816 TANK SETUP W.O.# SC1-3447816 W.O.# SC1-3447816 W.O.# SC1-3447816 W.O.# SC1-3447816 ALARM HISTORY W.O.# SC1-3447816 W.O.# SC1-3447816 W.O.# SC1-3447816 10' 20000 DWT6 Double Wall Tank 19951 Gals DIPSTICK GALLONS DIPSTICK GALLONS DIPSTICK GALLONS DIPSTICK GALLONS DIPSTICK GALLONS DIPSTICK GALLONS 1/8 6 6 1/8 365 12 1/8 997 18 1/8 1811 24 1/8 2764 30 1/8 3828 1/4 9 6 1/4 376 12 1/4 1012 18 1/4 1829 24 1/4 2785 30 1/4 3851 3/8 12 6 3/8 387 12 3/8 1028 18 3/8 1848 24 3/8 2806 30 3/8 3874 1/2 16 6 1/2 398 12 1/2 1043 18 1/2 1866 24 1/2 2827 30 1/2 3897 5/8 20 6 5/8 410 12 5/8 1059 18 5/8 1885 24 5/8 2849 30 5/8 3920 3/4 24 6 3/4 421 12 3/4 1074 18 3/4 1904 24 3/4 2870 30 3/4 3944 7/8 28 6 7/8 432 12 7/8 1090 18 7/8 1923 24 7/8 2891 30 7/8 3967 1 32 7 444 13 1106 19 1942 25 2913 31 3990 1 1/8 37 7 1/8 455 13 1/8 1121 19 1/8 1961 25 1/8 2934 31 1/8 4014 1 1/4 42 7 1/4 467 13 1/4 1137 19 1/4 1980 25 1/4 2956 31 1/4 4037 1 3/8 48 7 3/8 479 13 3/8 1153 19 3/8 1999 25 3/8 2977 31 3/8 4061 1 1/2 53 7 1/2 491 13 1/2 1169 19 1/2 2018 25 1/2 2999 31 1/2 4084 1 5/8 59 7 5/8 503 13 5/8 1185 19 5/8 2037 25 5/8 3020 31 5/8 4108 1 3/4 64 7 3/4 515 13 3/4 1202 19 3/4 2056 25 3/4 3042 31 3/4 4131 1 7/8 71 7 7/8 527 13 7/8 1218 19 7/8 2076 25 7/8 3064 31 7/8 4155 2 77 8 540 14 1234 20 2095 26 3086 32 4179 2 1/8 83 8 1/8 552 14 1/8 1251 20 1/8 2114 26 1/8 3107 32 1/8 4202 2 1/4 90 8 1/4 565 14 1/4 1267 20 1/4 2134 26 1/4 3129 32 1/4 4226 2 3/8 96 8 3/8 577 14 3/8 1284 20 3/8 2153 26 3/8 3151 32 3/8 4250 2 1/2 103 8 1/2 590 14 1/2 1300 20 1/2 2173 26 1/2 3173 32 1/2 4274 2 5/8 110 8 5/8 603 14 5/8 1317 20 5/8 2193 26 5/8 3195 32 5/8 4298 2 3/4 118 8 3/4 616 14 3/4 1334 20 3/4 2212 26 3/4 3217 32 3/4 4321 2 7/8 125 8 7/8 629 14 7/8 1350 20 7/8 2232 26 7/8 3239 32 7/8 4345 3 133 9 642 15 1367 21 2252 27 3261 33 436931339642151367212252273261334369 3 1/8 140 9 1/8 655 15 1/8 1384 21 1/8 2272 27 1/8 3283 33 1/8 4393 3 1/4 148 9 1/4 668 15 1/4 1401 21 1/4 2292 27 1/4 3306 33 1/4 4417 3 3/8 156 9 3/8 682 15 3/8 1418 21 3/8 2312 27 3/8 3328 33 3/8 4441 3 1/2 164 9 1/2 695 15 1/2 1435 21 1/2 2332 27 1/2 3350 33 1/2 4465 3 5/8 173 9 5/8 709 15 5/8 1453 21 5/8 2352 27 5/8 3373 33 5/8 4490 3 3/4 181 9 3/4 722 15 3/4 1470 21 3/4 2372 27 3/4 3395 33 3/4 4514 3 7/8 190 9 7/8 736 15 7/8 1487 21 7/8 2392 27 7/8 3417 33 7/8 4538 4 198 10 750 16 1505 22 2412 28 3440 34 4562 4 1/8 207 10 1/8 764 16 1/8 1522 22 1/8 2433 28 1/8 3462 34 1/8 4586 4 1/4 216 10 1/4 778 16 1/4 1540 22 1/4 2453 28 1/4 3485 34 1/4 4611 4 3/8 225 10 3/8 792 16 3/8 1557 22 3/8 2473 28 3/8 3507 34 3/8 4635 4 1/2 234 10 1/2 806 16 1/2 1575 22 1/2 2494 28 1/2 3530 34 1/2 4659 4 5/8 244 10 5/8 820 16 5/8 1593 22 5/8 2514 28 5/8 3553 34 5/8 4684 4 3/4 253 10 3/4 834 16 3/4 1611 22 3/4 2535 28 3/4 3575 34 3/4 4708 4 7/8 263 10 7/8 849 16 7/8 1628 22 7/8 2555 28 7/8 3598 34 7/8 4732 5 273 11 863 17 1646 23 2576 29 3621 35 4757 5 1/8 282 11 1/8 878 17 1/8 1664 23 1/8 2597 29 1/8 3644 35 1/8 4781 5 1/4 292 11 1/4 892 17 1/4 1682 23 1/4 2617 29 1/4 3666 35 1/4 4806 5 3/8 302 11 3/8 907 17 3/8 1701 23 3/8 2638 29 3/8 3689 35 3/8 4830 5 1/2 313 11 1/2 922 17 1/2 1719 23 1/2 2659 29 1/2 3712 35 1/2 4855 5 5/8 323 11 5/8 937 17 5/8 1737 23 5/8 2680 29 5/8 3735 35 5/8 4879 5 3/4 333 11 3/4 952 17 3/4 1755 23 3/4 2701 29 3/4 3758 35 3/4 4904 5 7/8 344 11 7/8 967 17 7/8 1774 23 7/8 2722 29 7/8 3781 35 7/8 4929 6 355 12 982 18 1792 24 2743 30 3804 36 4953 Containment Solutions, Inc.1 10' 20000 DWT6 Double Wall Tank 19951 Gals DIPSTICK GALLONS DIPSTICK GALLONS DIPSTICK GALLONS DIPSTICK GALLONS DIPSTICK GALLONS DIPSTICK GALLONS 36 1/8 4978 42 1/8 6196 48 1/8 7462 54 1/8 8759 60 1/8 10072 66 1/8 11383 36 1/4 5003 42 1/4 6222 48 1/4 7488 54 1/4 8786 60 1/4 10099 66 1/4 11410 36 3/8 5028 42 3/8 6248 48 3/8 7515 54 3/8 8814 60 3/8 10126 66 3/8 11437 36 1/2 5053 42 1/2 6274 48 1/2 7542 54 1/2 8841 60 1/2 10154 66 1/2 11464 36 5/8 5077 42 5/8 6300 48 5/8 7569 54 5/8 8868 60 5/8 10181 66 5/8 11491 36 3/4 5102 42 3/4 6326 48 3/4 7596 54 3/4 8895 60 3/4 10208 66 3/4 11519 36 7/8 5127 42 7/8 6352 48 7/8 7622 54 7/8 8923 60 7/8 10236 66 7/8 11546 37 5152 43 6378 49 7649 55 8950 61 10263 67 11573 37 1/8 5177 43 1/8 6404 49 1/8 7676 55 1/8 8977 61 1/8 10291 67 1/8 11600 37 1/4 5202 43 1/4 6430 49 1/4 7703 55 1/4 9005 61 1/4 10318 67 1/4 11627 37 3/8 5227 43 3/8 6456 49 3/8 7730 55 3/8 9032 61 3/8 10345 67 3/8 11654 37 1/2 5252 43 1/2 6482 49 1/2 7757 55 1/2 9059 61 1/2 10373 67 1/2 11681 37 5/8 5277 43 5/8 6508 49 5/8 7784 55 5/8 9086 61 5/8 10400 67 5/8 11708 37 3/4 5302 43 3/4 6534 49 3/4 7811 55 3/4 9114 61 3/4 10427 67 3/4 11736 37 7/8 5327 43 7/8 6561 49 7/8 7838 55 7/8 9141 61 7/8 10455 67 7/8 11763 38 5352 44 6587 50 7865 56 9168 62 10482 68 11790 38 1/8 5378 44 1/8 6613 50 1/8 7891 56 1/8 9196 62 1/8 10510 68 1/8 11817 38 1/4 5403 44 1/4 6639 50 1/4 7918 56 1/4 9223 62 1/4 10537 68 1/4 11844 38 3/8 5428 44 3/8 6666 50 3/8 7945 56 3/8 9250 62 3/8 10564 68 3/8 11871 38 1/2 5453 44 1/2 6692 50 1/2 7972 56 1/2 9278 62 1/2 10592 68 1/2 11898 38 5/8 5478 44 5/8 6718 50 5/8 7999 56 5/8 9305 62 5/8 10619 68 5/8 11925 38 3/4 5504 44 3/4 6745 50 3/4 8026 56 3/4 9332 62 3/4 10646 68 3/4 11952 38 7/8 5529 44 7/8 6771 50 7/8 8053 56 7/8 9360 62 7/8 10674 68 7/8 11979 39 5554 45 6797 51 8080 57 9387 63 10701 69 1200639555445679751808057938763107016912006 39 1/8 5580 45 1/8 6824 51 1/8 8107 57 1/8 9414 63 1/8 10728 69 1/8 12033 39 1/4 5605 45 1/4 6850 51 1/4 8135 57 1/4 9442 63 1/4 10756 69 1/4 12060 39 3/8 5631 45 3/8 6876 51 3/8 8162 57 3/8 9469 63 3/8 10783 69 3/8 12087 39 1/2 5656 45 1/2 6903 51 1/2 8189 57 1/2 9497 63 1/2 10810 69 1/2 12114 39 5/8 5681 45 5/8 6929 51 5/8 8216 57 5/8 9524 63 5/8 10838 69 5/8 12141 39 3/4 5707 45 3/4 6956 51 3/4 8243 57 3/4 9551 63 3/4 10865 69 3/4 12168 39 7/8 5732 45 7/8 6982 51 7/8 8270 57 7/8 9579 63 7/8 10892 69 7/8 12195 40 5758 46 7009 52 8297 58 9606 64 10920 70 12221 40 1/8 5784 46 1/8 7035 52 1/8 8324 58 1/8 9633 64 1/8 10947 70 1/8 12248 40 1/4 5809 46 1/4 7062 52 1/4 8351 58 1/4 9661 64 1/4 10974 70 1/4 12275 40 3/8 5835 46 3/8 7088 52 3/8 8378 58 3/8 9688 64 3/8 11001 70 3/8 12302 40 1/2 5860 46 1/2 7115 52 1/2 8406 58 1/2 9716 64 1/2 11029 70 1/2 12329 40 5/8 5886 46 5/8 7142 52 5/8 8433 58 5/8 9743 64 5/8 11056 70 5/8 12356 40 3/4 5912 46 3/4 7168 52 3/4 8460 58 3/4 9770 64 3/4 11083 70 3/4 12383 40 7/8 5937 46 7/8 7195 52 7/8 8487 58 7/8 9798 64 7/8 11110 70 7/8 12409 41 5963 47 7221 53 8514 59 9825 65 11138 71 12436 41 1/8 5989 47 1/8 7248 53 1/8 8541 59 1/8 9852 65 1/8 11165 71 1/8 12463 41 1/4 6015 47 1/4 7275 53 1/4 8569 59 1/4 9880 65 1/4 11192 71 1/4 12490 41 3/8 6040 47 3/8 7301 53 3/8 8596 59 3/8 9907 65 3/8 11219 71 3/8 12516 41 1/2 6066 47 1/2 7328 53 1/2 8623 59 1/2 9935 65 1/2 11247 71 1/2 12543 41 5/8 6092 47 5/8 7355 53 5/8 8650 59 5/8 9962 65 5/8 11274 71 5/8 12570 41 3/4 6118 47 3/4 7381 53 3/4 8677 59 3/4 9989 65 3/4 11301 71 3/4 12597 41 7/8 6144 47 7/8 7408 53 7/8 8705 59 7/8 10017 65 7/8 11328 71 7/8 12623 42 6170 48 7435 54 8732 60 10044 66 11356 72 12650 Containment Solutions, Inc.2 10' 20000 DWT6 Double Wall Tank 19951 Gals DIPSTICK GALLONS DIPSTICK GALLONS DIPSTICK GALLONS DIPSTICK GALLONS DIPSTICK GALLONS DIPSTICK GALLONS 72 1/8 12677 78 1/8 13937 84 1/8 15146 90 1/8 16285 96 1/8 17334 102 1/8 18269 72 1/4 12703 78 1/4 13962 84 1/4 15170 90 1/4 16308 96 1/4 17355 102 1/4 18287 72 3/8 12730 78 3/8 13988 84 3/8 15195 90 3/8 16331 96 3/8 17375 102 3/8 18305 72 1/2 12757 78 1/2 14014 84 1/2 15219 90 1/2 16353 96 1/2 17396 102 1/2 18323 72 5/8 12783 78 5/8 14040 84 5/8 15243 90 5/8 16376 96 5/8 17417 102 5/8 18341 72 3/4 12810 78 3/4 14065 84 3/4 15268 90 3/4 16399 96 3/4 17437 102 3/4 18359 72 7/8 12836 78 7/8 14091 84 7/8 15292 90 7/8 16421 96 7/8 17458 102 7/8 18376 73 12863 79 14117 85 15317 91 16444 97 17478 103 18394 73 1/8 12889 79 1/8 14142 85 1/8 15341 91 1/8 16467 97 1/8 17498 103 1/8 18412 73 1/4 12916 79 1/4 14168 85 1/4 15365 91 1/4 16489 97 1/4 17519 103 1/4 18429 73 3/8 12943 79 3/8 14193 85 3/8 15389 91 3/8 16512 97 3/8 17539 103 3/8 18447 73 1/2 12969 79 1/2 14219 85 1/2 15414 91 1/2 16534 97 1/2 17559 103 1/2 18464 73 5/8 12995 79 5/8 14244 85 5/8 15438 91 5/8 16556 97 5/8 17579 103 5/8 18481 73 3/4 13022 79 3/4 14270 85 3/4 15462 91 3/4 16579 97 3/4 17600 103 3/4 18499 73 7/8 13048 79 7/8 14295 85 7/8 15486 91 7/8 16601 97 7/8 17620 103 7/8 18516 74 13075 80 14321 86 15510 92 16623 98 17640 104 18533 74 1/8 13101 80 1/8 14346 86 1/8 15534 92 1/8 16646 98 1/8 17660 104 1/8 18550 74 1/4 13128 80 1/4 14372 86 1/4 15558 92 1/4 16668 98 1/4 17680 104 1/4 18567 74 3/8 13154 80 3/8 14397 86 3/8 15582 92 3/8 16690 98 3/8 17699 104 3/8 18584 74 1/2 13180 80 1/2 14422 86 1/2 15606 92 1/2 16712 98 1/2 17719 104 1/2 18601 74 5/8 13207 80 5/8 14448 86 5/8 15630 92 5/8 16734 98 5/8 17739 104 5/8 18618 74 3/4 13233 80 3/4 14473 86 3/4 15654 92 3/4 16756 98 3/4 17759 104 3/4 18635 74 7/8 13259 80 7/8 14498 86 7/8 15678 92 7/8 16778 98 7/8 17778 104 7/8 18651 75 13286 81 14523 87 15701 93 16800 99 17798 105 186687513286811452387157019316800991779810518668 75 1/8 13312 81 1/8 14549 87 1/8 15725 93 1/8 16822 99 1/8 17817 105 1/8 18684 75 1/4 13338 81 1/4 14574 87 1/4 15749 93 1/4 16844 99 1/4 17837 105 1/4 18701 75 3/8 13364 81 3/8 14599 87 3/8 15773 93 3/8 16866 99 3/8 17856 105 3/8 18717 75 1/2 13391 81 1/2 14624 87 1/2 15796 93 1/2 16888 99 1/2 17876 105 1/2 18734 75 5/8 13417 81 5/8 14649 87 5/8 15820 93 5/8 16909 99 5/8 17895 105 5/8 18750 75 3/4 13443 81 3/4 14674 87 3/4 15843 93 3/4 16931 99 3/4 17914 105 3/4 18766 75 7/8 13469 81 7/8 14699 87 7/8 15867 93 7/8 16953 99 7/8 17933 105 7/8 18782 76 13495 82 14724 88 15891 94 16974 100 17953 106 18798 76 1/8 13521 82 1/8 14749 88 1/8 15914 94 1/8 16996 100 1/8 17972 106 1/8 18814 76 1/4 13548 82 1/4 14774 88 1/4 15937 94 1/4 17017 100 1/4 17991 106 1/4 18830 76 3/8 13574 82 3/8 14799 88 3/8 15961 94 3/8 17039 100 3/8 18010 106 3/8 18846 76 1/2 13600 82 1/2 14824 88 1/2 15984 94 1/2 17060 100 1/2 18029 106 1/2 18861 76 5/8 13626 82 5/8 14849 88 5/8 16008 94 5/8 17081 100 5/8 18047 106 5/8 18877 76 3/4 13652 82 3/4 14874 88 3/4 16031 94 3/4 17103 100 3/4 18066 106 3/4 18893 76 7/8 13678 82 7/8 14899 88 7/8 16054 94 7/8 17124 100 7/8 18085 106 7/8 18908 77 13704 83 14924 89 16077 95 17145 101 18104 107 18924 77 1/8 13730 83 1/8 14948 89 1/8 16101 95 1/8 17166 101 1/8 18122 107 1/8 18939 77 1/4 13756 83 1/4 14973 89 1/4 16124 95 1/4 17187 101 1/4 18141 107 1/4 18954 77 3/8 13782 83 3/8 14998 89 3/8 16147 95 3/8 17209 101 3/8 18159 107 3/8 18969 77 1/2 13808 83 1/2 15023 89 1/2 16170 95 1/2 17230 101 1/2 18178 107 1/2 18985 77 5/8 13833 83 5/8 15047 89 5/8 16193 95 5/8 17251 101 5/8 18196 107 5/8 19000 77 3/4 13859 83 3/4 15072 89 3/4 16216 95 3/4 17271 101 3/4 18214 107 3/4 19015 77 7/8 13885 83 7/8 15096 89 7/8 16239 95 7/8 17292 101 7/8 18233 107 7/8 19029 78 13911 84 15121 90 16262 96 17313 102 18251 108 19044 Containment Solutions, Inc.3 10' 20000 DWT6 Double Wall Tank 19951 Gals DIPSTICK GALLONS DIPSTICK GALLONS 108 1/8 19059 114 1/8 19659 108 1/4 19074 114 1/4 19669 108 3/8 19088 114 3/8 19679 108 1/2 19103 114 1/2 19689 108 5/8 19117 114 5/8 19698 108 3/4 19131 114 3/4 19708 108 7/8 19146 114 7/8 19717 109 19160 115 19726 109 1/8 19174 115 1/8 19735 109 1/4 19188 115 1/4 19744 109 3/8 19202 115 3/8 19753 109 1/2 19215 115 1/2 19762 109 5/8 19229 115 5/8 19770 109 3/4 19243 115 3/4 19779 109 7/8 19256 115 7/8 19787 110 19270 116 19795 110 1/8 19283 116 1/8 19803 110 1/4 19296 116 1/4 19811 110 3/8 19310 116 3/8 19819 110 1/2 19323 116 1/2 19826 110 5/8 19336 116 5/8 19834 110 3/4 19349 116 3/4 19841 110 7/8 19361 116 7/8 19848 111 19374 117 19855 How To Properly Gauge Your Tank Underground storage tanks require periodic measurement to determine current inventory level. Using the proper methods when gauging your tank's contents will insure the most accurate reading and insure that you do not damage your tank. The following procedure should be followed whenever you use a gauge stick to determine the amount of product that is in your tank: 1) Use a wood dipstick with a rubber or nylon tip. Metallic dipsticks are not recommended. This will insure that frequent tank gaugings or an accidental dropping of the gauge stick into the tank will not damage the tank bottom. 2) Slowly lower your gauge stick into the fill port until it touches the tank bottom. Never free drop the gauge stick. This can result in inaccurate measurements due to product splashing. Free dropping can also result in gauge stick damage and tank damage. 3) Remove your dipstick slowly and read the product level directly from the gauge stick. Water Paste Detection To detect water in the tank bottom, water detection paste is available from petroleum equipment distributors. However, some water detection paste cannot detect antifreeze mixtures. If antifreeze mixtures are used for the cavity monitoring fluid, the following product is capable of detecting water or antifreeze (brine or up to 50 percent glycol) solution in the tank water bottoms: WATER FINDER #7686;1870 DAYCO/NATIONAL1111937411719855 111 1/8 19387 117 1/8 19862 111 1/4 19399 117 1/4 19868 111 3/8 19412 117 3/8 19875 111 1/2 19424 117 1/2 19881 111 5/8 19436 117 5/8 19887 111 3/4 19448 117 3/4 19893 111 7/8 19460 117 7/8 19898 112 19472 118 19904 112 1/8 19484 118 1/8 19909 112 1/4 19496 118 1/4 19914 112 3/8 19508 118 3/8 19919 112 1/2 19519 118 1/2 19923 112 5/8 19530 118 5/8 19928 112 3/4 19542 118 3/4 19932 112 7/8 19553 118 7/8 19936 113 19564 119 19939 113 1/8 19575 119 1/8 19942 113 1/4 19586 119 1/4 19945 113 3/8 19597 119 3/8 19948 113 1/2 19607 119 1/2 19950 113 5/8 19618 119 5/8 19951 113 3/4 19628 113 7/8 19639 114 19649 DAYCO/NATIONAL DAYTON, OH TEL: 1;800;283;2926 FAX: 1;800;688;4854 Caution Pressurized deliveries are not recommended. If the delivery vehicle uses pumps to fill the tank, install overfill shutoff equipment in the tank and truck to prevent the tank from being overfilled. Overfilling the tank under pressure will damage the tank even if the tank vent is unrestricted. Containment Solutions, Inc. 5150 Jefferson Chemical Road Conroe, TX 77301 Tel: 936 756 7731 Fax: 936 756 7766 Note: Calibration chart is based on the fluid level above a 5/16" deflector plate. Containment Solutions, Inc.4 10' 20000 DWT6 Double Wall Tank 19951 Gals Containment Solutions, Inc.5 6' 2000 DWT6 Double Wall Tank 2107 Gals DIPSTICK GALLONS DIPSTICK GALLONS DIPSTICK GALLONS DIPSTICK GALLONS DIPSTICK GALLONS 1/8 2 6 1/8 86 12 1/8 231 18 1/8 412 24 1/8 619 1/4 2 6 1/4 89 12 1/4 234 18 1/4 417 24 1/4 623 3/8 3 6 3/8 91 12 3/8 238 18 3/8 421 24 3/8 628 1/2 4 6 1/2 94 12 1/2 241 18 1/2 425 24 1/2 632 5/8 5 6 5/8 97 12 5/8 245 18 5/8 429 24 5/8 637 3/4 6 6 3/4 99 12 3/4 248 18 3/4 433 24 3/4 641 7/8 7 6 7/8 102 12 7/8 252 18 7/8 437 24 7/8 646 1 8 7 104 13 255 19 441 25 650 1 1/8 9 7 1/8 107 13 1/8 259 19 1/8 445 25 1/8 655 1 1/4 10 7 1/4 110 13 1/4 263 19 1/4 450 25 1/4 660 1 3/8 11 7 3/8 113 13 3/8 266 19 3/8 454 25 3/8 664 1 1/2 13 7 1/2 115 13 1/2 270 19 1/2 458 25 1/2 669 1 5/8 14 7 5/8 118 13 5/8 273 19 5/8 462 25 5/8 673 1 3/4 16 7 3/4 121 13 3/4 277 19 3/4 466 25 3/4 678 1 7/8 17 7 7/8 124 13 7/8 281 19 7/8 470 25 7/8 682 2 18 8 127 14 284 20 475 26 687 2 1/8 20 8 1/8 129 14 1/8 288 20 1/8 479 26 1/8 692 2 1/4 22 8 1/4 132 14 1/4 292 20 1/4 483 26 1/4 696 2 3/8 23 8 3/8 135 14 3/8 295 20 3/8 487 26 3/8 701 2 1/2 25 8 1/2 138 14 1/2 299 20 1/2 492 26 1/2 705 2 5/8 26 8 5/8 141 14 5/8 303 20 5/8 496 26 5/8 710 2 3/4 28 8 3/4 144 14 3/4 307 20 3/4 500 26 3/4 715 2 7/8 30 8 7/8 147 14 7/8 310 20 7/8 505 26 7/8 719 3 32 9 150 15 314 21 509 27 724 3 1/8 34 9 1/8 153 15 1/8 318 21 1/8 513 27 1/8 728 3 1/4 35 9 1/4 156 15 1/4 322 21 1/4 517 27 1/4 733 3 3/8 37 9 3/8 159 15 3/8 326 21 3/8 522 27 3/8 738 3 1/2 39 9 1/2 162 15 1/2 329 21 1/2 526 27 1/2 742 3 5/8 41 9 5/8 165 15 5/8 333 21 5/8 530 27 5/8 747 3 3/4 43 9 3/4 168 15 3/4 337 21 3/4 535 27 3/4 752 3 7/8 45 9 7/8 172 15 7/8 341 21 7/8 539 27 7/8 756 4 47 10 175 16 345 22 543 28 761 4 1/8 49 10 1/8 178 16 1/8 349 22 1/8 548 28 1/8 766 4 1/4 51 10 1/4 181 16 1/4 353 22 1/4 552 28 1/4 770 4 3/8 54 10 3/8 184 16 3/8 356 22 3/8 557 28 3/8 775 4 1/2 56 10 1/2 188 16 1/2 360 22 1/2 561 28 1/2 780 4 5/8 58 10 5/8 191 16 5/8 364 22 5/8 565 28 5/8 784 4 3/4 60 10 3/4 194 16 3/4 368 22 3/4 570 28 3/4 789 4 7/8 62 10 7/8 197 16 7/8 372 22 7/8 574 28 7/8 794 5 65 11 201 17 376 23 579 29 799 5 1/8 67 11 1/8 204 17 1/8 380 23 1/8 583 29 1/8 803 5 1/4 69 11 1/4 207 17 1/4 384 23 1/4 588 29 1/4 808 5 3/8 72 11 3/8 211 17 3/8 388 23 3/8 592 29 3/8 813 5 1/2 74 11 1/2 214 17 1/2 392 23 1/2 596 29 1/2 817 5 5/8 76 11 5/8 217 17 5/8 396 23 5/8 601 29 5/8 822 5 3/4 79 11 3/4 221 17 3/4 400 23 3/4 605 29 3/4 827 5 7/8 81 11 7/8 224 17 7/8 404 23 7/8 610 29 7/8 831 6 84 12 228 18 408 24 614 30 836 Containment Solutions, Inc.1 6' 2000 DWT6 Double Wall Tank 2107 Gals DIPSTICK GALLONS DIPSTICK GALLONS DIPSTICK GALLONS DIPSTICK GALLONS DIPSTICK GALLONS 30 1/8 841 36 1/8 1070 42 1/8 1299 48 1/8 1520 54 1/8 1723 30 1/4 846 36 1/4 1075 42 1/4 1304 48 1/4 1524 54 1/4 1727 30 3/8 850 36 3/8 1080 42 3/8 1309 48 3/8 1529 54 3/8 1731 30 1/2 855 36 1/2 1085 42 1/2 1313 48 1/2 1533 54 1/2 1735 30 5/8 860 36 5/8 1090 42 5/8 1318 48 5/8 1537 54 5/8 1739 30 3/4 865 36 3/4 1094 42 3/4 1323 48 3/4 1542 54 3/4 1743 30 7/8 869 36 7/8 1099 42 7/8 1327 48 7/8 1546 54 7/8 1747 31 874 37 1104 43 1332 49 1551 55 1751 31 1/8 879 37 1/8 1109 43 1/8 1337 49 1/8 1555 55 1/8 1755 31 1/4 884 37 1/4 1114 43 1/4 1342 49 1/4 1559 55 1/4 1759 31 3/8 888 37 3/8 1118 43 3/8 1346 49 3/8 1564 55 3/8 1762 31 1/2 893 37 1/2 1123 43 1/2 1351 49 1/2 1568 55 1/2 1766 31 5/8 898 37 5/8 1128 43 5/8 1356 49 5/8 1572 55 5/8 1770 31 3/4 903 37 3/4 1133 43 3/4 1360 49 3/4 1577 55 3/4 1774 31 7/8 907 37 7/8 1138 43 7/8 1365 49 7/8 1581 55 7/8 1778 32 912 38 1142 44 1369 50 1585 56 1782 32 1/8 917 38 1/8 1147 44 1/8 1374 50 1/8 1590 56 1/8 1786 32 1/4 922 38 1/4 1152 44 1/4 1379 50 1/4 1594 56 1/4 1789 32 3/8 927 38 3/8 1157 44 3/8 1383 50 3/8 1598 56 3/8 1793 32 1/2 931 38 1/2 1162 44 1/2 1388 50 1/2 1603 56 1/2 1797 32 5/8 936 38 5/8 1166 44 5/8 1393 50 5/8 1607 56 5/8 1801 32 3/4 941 38 3/4 1171 44 3/4 1397 50 3/4 1611 56 3/4 1804 32 7/8 946 38 7/8 1176 44 7/8 1402 50 7/8 1616 56 7/8 1808 33 950 39 1181 45 1406 51 1620 57 1812 33 1/8 955 39 1/8 1185 45 1/8 1411 51 1/8 1624 57 1/8 1816 33 1/4 960 39 1/4 1190 45 1/4 1416 51 1/4 1628 57 1/4 1819 33 3/8 965 39 3/8 1195 45 3/8 1420 51 3/8 1633 57 3/8 1823 33 1/2 970 39 1/2 1200 45 1/2 1425 51 1/2 1637 57 1/2 1827 33 5/8 974 39 5/8 1205 45 5/8 1429 51 5/8 1641 57 5/8 1830 33 3/4 979 39 3/4 1209 45 3/4 1434 51 3/4 1645 57 3/4 1834 33 7/8 984 39 7/8 1214 45 7/8 1439 51 7/8 1649 57 7/8 1837 34 989 40 1219 46 1443 52 1654 58 1841 34 1/8 994 40 1/8 1224 46 1/8 1448 52 1/8 1658 58 1/8 1845 34 1/4 998 40 1/4 1228 46 1/4 1452 52 1/4 1662 58 1/4 1848 34 3/8 1003 40 3/8 1233 46 3/8 1457 52 3/8 1666 58 3/8 1852 34 1/2 1008 40 1/2 1238 46 1/2 1461 52 1/2 1670 58 1/2 1855 34 5/8 1013 40 5/8 1243 46 5/8 1466 52 5/8 1674 58 5/8 1859 34 3/4 1018 40 3/4 1247 46 3/4 1470 52 3/4 1678 58 3/4 1862 34 7/8 1022 40 7/8 1252 46 7/8 1475 52 7/8 1683 58 7/8 1866 35 1027 41 1257 47 1479 53 1687 59 1869 35 1/8 1032 41 1/8 1262 47 1/8 1484 53 1/8 1691 59 1/8 1873 35 1/4 1037 41 1/4 1266 47 1/4 1488 53 1/4 1695 59 1/4 1876 35 3/8 1042 41 3/8 1271 47 3/8 1493 53 3/8 1699 59 3/8 1880 35 1/2 1046 41 1/2 1276 47 1/2 1497 53 1/2 1703 59 1/2 1883 35 5/8 1051 41 5/8 1280 47 5/8 1502 53 5/8 1707 59 5/8 1887 35 3/4 1056 41 3/4 1285 47 3/4 1506 53 3/4 1711 59 3/4 1890 35 7/8 1061 41 7/8 1290 47 7/8 1511 53 7/8 1715 59 7/8 1893 36 1066 42 1295 48 1515 54 1719 60 1897 Containment Solutions, Inc.2 6' 2000 DWT6 Double Wall Tank 2107 Gals DIPSTICK GALLONS DIPSTICK GALLONS 60 1/8 1900 66 1/8 2038 60 1/4 1903 66 1/4 2040 60 3/8 1907 66 3/8 2043 60 1/2 1910 66 1/2 2045 60 5/8 1913 66 5/8 2047 60 3/4 1916 66 3/4 2049 60 7/8 1920 66 7/8 2052 61 1923 67 2054 61 1/8 1926 67 1/8 2056 61 1/4 1929 67 1/4 2058 61 3/8 1932 67 3/8 2060 61 1/2 1936 67 1/2 2062 61 5/8 1939 67 5/8 2064 61 3/4 1942 67 3/4 2066 61 7/8 1945 67 7/8 2068 62 1948 68 2070 62 1/8 1951 68 1/8 2072 62 1/4 1954 68 1/4 2074 62 3/8 1957 68 3/8 2075 62 1/2 1960 68 1/2 2077 62 5/8 1963 68 5/8 2079 62 3/4 1966 68 3/4 2081 62 7/8 1969 68 7/8 2082 63 1972 69 2084 63 1/8 1975 69 1/8 2086 63 1/4 1978 69 1/4 2087 63 3/8 1981 69 3/8 2089 63 1/2 1983 69 1/2 2090 63 5/8 1986 69 5/8 2092 63 3/4 1989 69 3/4 2093 63 7/8 1992 69 7/8 2094 64 1995 70 2096 64 1/8 1997 70 1/8 2097 64 1/4 2000 70 1/4 2098 64 3/8 2003 70 3/8 2099 64 1/2 2005 70 1/2 2100 64 5/8 2008 70 5/8 2102 64 3/4 2011 70 3/4 2103 64 7/8 2013 70 7/8 2103 65 2016 71 2104 65 1/8 2018 71 1/8 2105 65 1/4 2021 71 1/4 2106 65 3/8 2023 71 3/8 2106 65 1/2 2026 71 1/2 2107 65 5/8 2028 71 5/8 2107 65 3/4 2031 65 7/8 2033 66 2036 HOW TO PROPERLY GAUGE YOUR TANK: Underground storage tanks require periodic measurement to determine current inventory level. Using the proper methods when gauging your tank's contents will insure the most accurate reading and insure that you do not damage your tank. The following procedure should be followed whenever you use a gauge stick to determine the amount of product that is in your tank: 1) Use a wood dipstick with a rubber or nylon tip. Metallic dipsticks are not recommended. This will insure that frequent tank gaugings or an accidental dropping of the gauge stick into the tank will not damage the tank bottom. 2) Slowly lower your gauge stick into the fill port until it touches the tank bottom. Never free drop the gauge stick. This can result in inaccurate measurements due to product splashing. Free dropping can also result in gauge stick damage and tank damage. 3) Remove your dipstick slowly and read the product level directly from the gauge stick. WaterPaste Detection To detect water in the tank bottom, water detection paste is available from petroleum equipment distributors. However, some water detection paste cannot detect antifreeze mixtures. If antifreeze mixtures are used for the cavity monitoring fluid, the following product is capable of detecting water or antifreeze (brine or up to 50 percent glycol) solution in the tank water bottoms: WATER FINDER #7686;1870 DAYCO/NATIONAL DAYTON, OH TEL: 1;800;283;2926 FAX: 1;800;688;4854 Caution Pressurized deliveries are not recommended. If the delivery vehicle uses pumps to fill the tank, install overfill shutoff equipment in the tank and truck to prevent the tank from being overfilled.Overfilling the tank under pressure will damage the tank even if the tank vent is unrestricted. Containment Solutions, Inc. 5150 Jefferson Chemical Road Conroe, TX 77301 Tel: 936 756 7731 Fax: 936 756 7766 Note: Calibration chart is based on the fluid level above a 5/16"deflector plate. Containment Solutions, Inc.3 Test Duration Test Pressure P/F Threshold Tank Annular - Vacuum 1 hr, 20k or less tank 10" hg 0 loss, int dry before and after test Tank Annular - Vacuum 2 hr, >20k tank 10" hg 0 loss, int dry before and after test Line Annular - Pressure 1 hr 5 psi 0 loss STP Sump - Hydro 1 hr 4" above highest penetration or sidewall seam less than 1/8" over hour, settle time of 15 minutes minimum prior to starting the test UDC Sump - Hydro 1 hr 4" above highest penetration or sidewall seam less than 1/8" over hour, settle time of 15 minutes minimum prior to starting the test Spill Bucket - SW Vac 1 min 30" wc no greater than 4" wc vaccum decay - bucket must be dry Spill Bucket - SW Hydro 1 hr within 1.5" of top of the bucket less than 1/8" over hour, settle time of 5 minutest minimum prior to starting the test Spill Bucket - DW Vac 1 min 15" wc no greater than 3" wc vaccum decay - int must be dry