HomeMy WebLinkAboutFMC 2020Appendix VI
Underground Storage Tank
Monitoring System Certification Form
CERS = California Environmental Reporting System, GPH = Gallons Per Hour, ID = Identification,
ICC = International Code Council, LLD = Line Leak Detector, NA = Not Applicable, SW = Single-
Walled, UDC = Under-Dispenser Containment, UST = Underground Storage Tank,
VPH = Vacuum/Pressure/Hydrostatic
Page 1 of 6
TYPE OF ACTION Installation Repair 12 Month
1. FACILITY INFORMATION
CERS ID Certification Date
Facility Name
Facility Address City ZIP Code
2. SERVICE TECHNICIAN INFORMATION
Company Performing the Certification Phone
Mailing Address
Service Technician Performing Test
Contractor/Tank Tester License Number
ICC Number ICC Expiration Date
3.TRAINING AND CERTIFICATIONS
Manufacturer and Test Equipment Training Certifications Expiration Date
4.CERTIFICATION BY SERVICE TECHNICIAN CONDUCTING TEST
I hereby certify that the monitoring system is operational in accordance with California Code
of Regulations, title 23, division 3, chapter 16, section 2638; that required supporting
documentation is attached; and all information contained herein is accurate.
Service Technician Signature Date Total # of Pages
Underground Storage Tank
Monitoring System Certification Form
Page 2 of 6
5.MONITORING SYSTEM AND PROGRAMMING
A separate Monitoring System Certification Form must be prepared for each control panel.
Make of Monitoring System
Control Panel
Model of Monitoring System
Control Panel
Software Version Installed
Attach the post-certification reports if the monitoring system is capable of generating
either; Monitoring System Set-up Alarm History Report Yes No NA
All monitoring equipment is operational per manufacturer’s specifications?
Secondary containment systems are free of damage, debris, or liquid?
Are the audible and visual alarms operational?
All sensors have been: 1) visually inspected for wiring kinks, breaks and residual
buildup on floats; and 2) tested for functionality and confirmed operational?
Are all sensors installed to detect a release at the earliest opportunity in the
secondary containment?
The monitoring system set-up was reviewed, and proper settings confirmed?
Was the monitoring control panel’s backup battery visually inspected, functionally
tested, and confirmed operational?
Does the flow of fuel stop at the dispenser if a release is detected in the under-
dispenser containment?
Does the turbine automatically shut down if the piping secondary containment
monitoring system fails to operate or is electrically disconnected?
Does the turbine automatically shut down if the piping secondary containment
monitoring system detects a release? Which sensors initiate positive shut down?
(Check all that apply) Sump UDC
If monitoring system alarms are relayed to a remote monitoring center, is all
communication equipment operational?
Describe all answers marked “No” or “Fail” and proposed remedy in Section 9.
List all monitoring equipment either replaced or repaired in Section 9
Underground Storage Tank
Monitoring System Certification Form
Page 3 of 6
6. SENSOR TESTING RESULTS
List only sensors tested on date of this certification. List “Sensor ID” as labeled in system
programming. Additional copies of this page may be attached to accommodate all sensors tested.
Sensor ID Sensor Model Component(s) Monitored Pass Fail
Describe all answers marked “No” or “Fail” and proposed remedy in Section 9.
List all monitoring equipment either replaced or repaired in Section 9
Underground Storage Tank
Monitoring System Certification Form
Page 4 of 6
7. LINE LEAK DETECTOR TESTING
Check this box if line leak detectors ARE NOT installed. (Do not complete this section.)
Simulated release rate verified: (Check all that apply.)
3 GPH 0.1 GPH 0.2 GPH Yes No NA
Has the testing apparatus been properly calibrated?
For emergency generator tank systems, does the LLD create an audible and visual
alarm when a leak is detected?
For mechanical LLDs, does the LLD restrict the flow through the pipe when a
release is detected?
For electronic LLDs, does the turbine automatically shut off when a release is
detected?
For electronic LLDs, does the turbine automatically shut off if any portion of the
monitoring system is disabled or disconnected?
For electronic LLDs, does the turbine automatically shut off if any portion of the
monitoring system malfunctions or fails a tightness test?
For electronic LLDs, have all accessible wiring connections been visually inspected
for kinks and breaks?
Were all items on the equipment manufacturer’s maintenance checklist completed?
Were all LLDs confirmed operational within regulatory requirements?
LLD ID LLD Model Lines Monitored Pass Fail
Describe all answers marked “No” or “Fail” and proposed remedy in Section 9.
List all monitoring equipment either replaced or repaired in Section 9
Underground Storage Tank
Monitoring System Certification Form
Page 5 of 6
8. IN-TANK GAUGING TESTING
Check this box if tank gauging is used only for inventory control.
Check this box if NO tank gauging equipment is installed.
(Do not complete this section if either box is checked.)
Yes No NA
All wiring has been: 1) visually inspected for kinks, breaks and proper entry and
termination; and 2) tested for ground faults?
Were all in-tank gauging probes visually inspected for damage and residue buildup
to ensure that floats move freely, functionally tested, and confirmed operational?
Was accuracy of system’s product level readings tested?
Was accuracy of system’s water level readings tested?
Were all probes reinstalled properly?
Were all items on the equipment manufacturer’s maintenance checklist completed?
Probe ID Probe Model Tanks Monitored Pass Fail
9. COMMENTS
Describe all answers marked “No” or “Fail” and proposed remedy.
List all monitoring equipment either replaced or repaired.
UDC-1UDC-2
U
D
C
-
3
U
D
C
-
4
1234
5
6
7
8
Diesel 91 Premium 87 Unleaded 22,000 GALLONS UST-1
8
,
0
0
0
G
A
L
L
O
N
S
U
S
T
-
2
20,000 GALLONS UST-3 TS-3 TS-1TS-2 FS-1
F
S
-
2
FS-3 AA V VVV DISPENSER
U
D
C
1
-
2
536 SENSO
R
D
I
S
P
E
N
S
E
R
U
D
C
3
-
4
5
3
6
S
E
N
S
O
R
D
I
S
P
E
N
S
E
R
U
D
C
5
-
6
5
3
6
S
E
N
S
O
R
D
I
S
P
E
N
S
E
R
U
D
C
7
-
8
5
3
6
S
E
N
S
O
R
87 TURBINE SUMP536 SENSOR480 SENSOR99LD LINE LEAK DETECTORVACUUM SENSOR KIT #11-2-3-4-5-6-7-8 PRODUCT LINEDIESEL TURBINE SUMP536 SENSOR480 SENSOR99LD LINE LEAK DETECTORVACUUM SENSOR KIT #31-2-7-8 PRODUCT LINE91 TURBINE SUMP536 SENSOR480 SENSOR99LD LINE LEAK DETECTORVACUUM SENSOR KIT #21-2-3-4-5-6-7-8 PRODUCT LINE87 FILL SUMP536 SENSORDIESEL FILL SUMP536 SENSOR
P
R
E
M
I
U
M
F
I
L
L
S
U
M
P
5
3
6
S
E
N
S
O
R
DIESEL ANNULAR303 SENSOR
8
7
9
1
A
N
N
U
L
A
R
3
0
3
S
E
N
S
O
R
HEALY CLE
A
N
A
I
R
S
E
P
E
R
A
T
O
R
V
E
N
T
S
U
M
P
T
R
A
N
S
I
T
I
O
N
S
U
M
P
5
3
6
S
E
N
S
O
R
ZONE # 1-87 REGULARZONE#4- 91 PREMIUM ZONE #2- 87 VAPOR LINE
Z
O
N
E
#
3
-
8
7
V
E
N
T
L
I
N
E
Z
O
N
E
#
7
-
D
I
E
S
E
L
V
E
N
T
L
I
N
E
Z
O
N
E
#
5
-
9
1
V
E
N
T
L
I
N
E
SLOPE 18" P
E
R
F
O
O
T
M
I
N
.
T
O
T
A
N
K
S
S
T
O
R
E
E
L
E
C
T
R
I
C
A
L
T
I
E
I
N
FIRE HYDRANT
E
S
T
O
P
T
L
S
H
A
G
E
M
A
N
R
D
COFFEE RD30K SPLIT TANK
L
E
G
E
N
D
V
A
C
U
U
M
S
E
N
S
O
R
K
I
T
#
1
-
8
7
T
U
R
B
I
N
E
Z
O
N
E
1
8
7
B
R
U
G
G
P
R
O
D
U
C
T
Z
O
N
E
2
8
7
V
A
P
O
R
L
I
N
E
Z
O
N
E
3
8
7
V
E
N
T
L
I
N
E
V
A
C
U
U
M
S
E
N
S
O
R
K
I
T
#
2
-
9
1
T
U
R
B
I
N
E
Z
O
N
E
4
9
1
B
R
U
G
G
P
R
O
D
U
C
T
Z
O
N
E
5
9
1
V
E
N
T
L
I
N
E
V
A
C
U
U
M
S
E
N
S
O
R
K
I
T
#
3
-
D
I
E
S
E
L
T
U
R
B
I
N
E
Z
O
N
E
6
D
I
E
S
E
L
B
R
U
G
G
P
R
O
D
U
C
T
Z
O
N
E
7
D
I
E
S
E
L
V
E
N
T
L
I
N
E
V
E
E
D
E
R
R
O
O
T
S
E
N
S
O
R
,
P
R
O
B
E
S
,
L
E
A
K
D
E
T
E
C
T
O
R
S
4
D
I
S
P
E
N
S
E
R
+
U
D
C
U
D
C
1
,
2
,
3
,
4
3
3
0
0
2
0
-
5
3
6
H
Y
D
R
O
S
T
A
T
I
C
D
I
S
P
E
N
S
E
R
P
A
N
S
E
N
S
O
R
2
A
N
N
U
L
A
R
S
3
0
K
S
P
L
I
T
+
2
0
K
3
3
0
0
2
0
-
5
3
6
H
Y
D
R
O
S
T
A
T
I
C
D
I
S
P
E
N
S
E
R
P
A
N
S
E
N
S
O
R
7
9
4
3
8
0
-
3
0
3
B
R
I
N
E
S
E
N
S
O
R
3
T
U
R
B
I
N
E
S
U
M
P
S
8
7
,
9
1
,
D
I
E
S
E
L
P
R
O
D
U
C
T
S
3
3
0
0
2
0
-
5
3
6
H
Y
D
R
O
S
T
A
T
I
C
D
I
S
P
E
N
S
E
R
P
A
N
S
E
N
S
O
R
3
3
0
0
2
0
-
4
8
0
V
A
C
U
U
M
S
E
N
S
O
R
1
1
6
-
0
5
7
-
5
L
I
N
E
L
E
A
K
D
E
T
E
C
T
O
R
3
F
I
L
L
S
U
M
P
S
8
7
,
9
1
,
D
I
E
S
E
L
3
3
0
0
2
0
-
5
3
6
H
Y
D
R
O
S
T
A
T
I
C
D
I
S
P
E
N
S
E
R
P
A
N
S
E
N
S
O
R
1
V
E
N
T
S
U
M
P
H
E
A
L
Y
T
A
N
K
3
3
0
0
2
0
-
5
3
6
H
Y
D
R
O
S
T
A
T
I
C
D
I
S
P
E
N
S
E
R
P
A
N
S
E
N
S
O
R
3
T
A
N
K
P
R
O
B
E
S
8
7
,
9
1
,
D
I
E
S
E
L
8
4
6
3
9
0
-
1
1
0
M
A
G
P
R
O
B
E
3
L
E
A
K
D
E
T
E
C
T
O
R
S
8
7
,
9
1
,
D
I
E
S
E
L
9
9
L
D
-
2
0
0
0
V
M
I
L
I
N
E
L
E
A
K
D
E
T
E
C
T
O
R
6
"
X
7
F
O
O
T
B
O
L
L
A
R
D
S
H
B
P
R
O
P
A
N
E
T
A
N
K
SITE MAP
=
P
e
n
e
t
r
a
t
i
o
n
s
B
R
A
V
O
F
-
7
5
-
P
E
-
B
R
G
-
D
(
6
5
)
F
O
R
P
R
O
D
U
C
T
=
P
e
n
e
t
r
a
t
i
o
n
s
B
R
A
V
O
F
-
3
2
-
T
S
-
D
B
R
A
V
O
F
B
(
5
1
)
F
O
R
V
A
P
O
R
/
V
E
N
T
NORTHZONE# 6- DIESELPRICE SIGN AIR /WATER
S
I
T
E
H
A
Z
M
A
T
I
N
V
E
N
T
O
R
Y
C
A
R
B
O
N
D
I
O
X
I
D
E
L
I
Q
U
I
D
A
B
S
O
R
B
A
N
T
P
A
D
S
C
I
M
-
T
E
K
F
I
L
T
E
R
S
L
I
Q
U
E
F
I
E
D
P
E
T
R
O
L
E
U
M
G
A
S
(
L
P
G
)
G
A
S
O
L
I
N
E
A
L
L
G
R
A
D
E
S
D
I
E
S
E
L
F
U
E
L
N
O
.
2
C
O
2
C
O
2
F
I
R
E
S
U
P
R
E
S
S
I
O
N
C
I
R
C
U
I
T
B
R
E
A
K
E
R
WATER METER SHUTOFF
O
V
E
R
F
I
L
L
A
L
A
R
M
C
I
M
-
T
E
K
F
I
L
T
E
R
S
O
U
T
S
I
D
E
A
B
S
O
R
B
A
N
T
P
A
D
S
O
U
T
S
I
D
E
Appendix VIII Underground Storage Tank Spill Container Testing Report Form
CERS = California Environmental Reporting System, ID = Identification, ICC = International Code
Council
Page 1 of 2
TYPE OF ACTION ☐ Installation ☐ Repair ☐ 12 Month
1. FACILITY INFORMATION
CERS ID
Test Date
Facility Name
Facility Address
City
ZIP Code
2. SERVICE TECHNICIAN INFORMATION
Company Performing the Test
Phone
Mailing Address
Service Technician Performing Test
Contractor/Tank Tester License Number
ICC Number
ICC Expiration Date
3. TRAINING AND CERTIFICATIONS
Manufacturer and Test Equipment Training Certifications Expiration Date
4. TEST PROCEDURE INFORMATION
Test Procedures Used Components Tested
5. CERTIFICATION BY SERVICE TECHNICIAN CONDUCTING TEST
I hereby certify that each spill container was tested in accordance with California Code of
Regulations, title 23, division 3, chapter 16, section 2637.1; that required supporting
documentation is attached; and all information contained herein is accurate. I understand
that test procedures shall be made available upon request by the governing authority.
Service Technician Signature Date
Total # of Pages
Underground Storage Tank Spill Container Testing Report Form
Additional copies of this page may be attached.
Page 2 of 2
6. SPILL CONTAINER DETAILS
Test Method Developed by ☐ Manufacturer ☐ Industry Standard ☐ Professional Engineer
Test Type ☐ Pressure ☐ Vacuum ☐ Hydrostatic
Tank ID
Spill Container Manufacturer:
Method of Cathodic Protection ☐ Nonmetallic
☐ Other
☐ Nonmetallic
☐ Other
☐ Nonmetallic
☐ Other
☐ Nonmetallic
☐ Other
Is the spill container minimum
capacity five gallons excluding
riser volume?
☐ Yes
☐ No*
☐ Yes
☐ No*
☐ Yes
☐ No*
☐ Yes
☐ No*
Method to keep spill container
empty
☐ Drain
☐ Pump
☐ Other
☐ Drain
☐ Pump
☐ Other
☐ Drain
☐ Pump
☐ Other
☐ Drain
☐ Pump
☐ Other
Spill Container Test Results ☐ Pass
☐ Fail
☐ Pass
☐ Fail
☐ Pass
☐ Fail
☐ Pass
☐ Fail
Tank ID
Spill Container Manufacturer:
Method of Cathodic Protection ☐ Nonmetallic
☐ Other
☐ Nonmetallic
☐ Other
☐ Nonmetallic
☐ Other
☐ Nonmetallic
☐ Other
Is the spill container minimum
capacity five gallons excluding
riser volume?
☐ Yes
☐ No*
☐ Yes
☐ No*
☐ Yes
☐ No*
☐ Yes
☐ No*
Method to keep spill container
empty
☐ Drain
☐ Pump
☐ Other
☐ Drain
☐ Pump
☐ Other
☐ Drain
☐ Pump
☐ Other
☐ Drain
☐ Pump
☐ Other
Spill Container Test Results ☐ Pass
☐ Fail
☐ Pass
☐ Fail
☐ Pass
☐ Fail
☐ Pass
☐ Fail
1 8. COMMENTS
Describe all answers marked “Other,” “No,” or “Fail” and each proposed remedy.
* Mark here if:
Spill containers do not have a minimum capacity of five gallons and require replacement.
file:///C/Users/jerryr/Desktop/Riverlakes%20Monitor/Riverlakes%20setup.txt[12/4/2020 11:33:56 AM]
<
I20100NOV 17, 2020 2:08 PM
BROOKSIDE MARKET
4700 COFFEE RD BAKERSFIELD CA 93308
661-588-1338
IN-TANK INVENTORY
TANK PRODUCT VOLUME TC VOLUME ULLAGE HEIGHT WATER TEMP 1 87 UNLEADED 11608 11543 9959 63.18 0.00 68.00
2 91 PREMIUM 6092 6043 2439 80.30 0.00 71.43 3 DIESEL 3564 3560 16387 28.68 0.00 83.31
>
<I90500
NOV 17, 2020 2:08 PMSOFTWARE REVISION LEVEL
VERSION 335.00SOFTWARE# 346335-100-A
CREATED - 18.08.27.10.22
S-MODULE# 330160-004-aSYSTEM FEATURES:
PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS
ISD/APM
><
I50201NOV 17, 2020 2:08 PM
SHIFT TIME 1 : 1:00 AM
>
<I50202
NOV 17, 2020 2:08 PM
SHIFT TIME 2 : DISABLED
><
I50203NOV 17, 2020 2:08 PM
SHIFT TIME 3 : DISABLED
>
file:///C/Users/jerryr/Desktop/Riverlakes%20Monitor/Riverlakes%20setup.txt[12/4/2020 11:33:56 AM]
<
I50204NOV 17, 2020 2:08 PM
SHIFT TIME 4 : DISABLED
>
<I54600
NOV 17, 2020 2:08 PM
TANK PER TST NEEDED WRN: DISABLED
><
I54900NOV 17, 2020 2:08 PM
TANK ANN TST NEEDED WRN: DISABLED
>
<I55300
NOV 17, 2020 2:08 PM
LINE RE-ENABLE METHODALARM ACKNOWLEDGE
>
<I55600
NOV 17, 2020 2:09 PM
LINE PER TST NEEDED WRN: DISABLED
><
I55900NOV 17, 2020 2:09 PM
LINE ANN TST NEEDED WRN: DISABLED
>
<I51400
NOV 17, 2020 2:09 PM
H-PROTOCOL DATA FORMATHEIGHT
>
<I51A01
NOV 17, 2020 2:09 PM
file:///C/Users/jerryr/Desktop/Riverlakes%20Monitor/Riverlakes%20setup.txt[12/4/2020 11:33:56 AM]
DAYLIGHT SAVING TIMEENABLED OFF
>
<I51B00
NOV 17, 2020 2:09 PM
DAYLIGHT SAVING TIME
START DATE MAR WEEK 2 SUN 2:00 AM
END DATE NOV WEEK 1 SUN 2:00 AM
><
I51600NOV 17, 2020 2:09 PM
RE-DIRECT LOCAL PRINTOUT
DISABLED
><
I50400NOV 17, 2020 2:09 PM
232 SECURITY CODE
PORT SECURITY CODE STATUS
1 000000 DISABLED
2 000000 DISABLED 3 000000 DISABLED
4 000000 DISABLED 5 000000 DISABLED
6 000000 DISABLED
><
I21900NOV 17, 2020 2:09 PM
TANK CHART SECURITY
DISABLED
><
I5BD00NOV 17, 2020 2:09 PM
file:///C/Users/jerryr/Desktop/Riverlakes%20Monitor/Riverlakes%20setup.txt[12/4/2020 11:33:56 AM]
CUSTOM ALARM LABELS
DISABLED
>
<I56000
NOV 17, 2020 2:09 PM
MASS/DENSITY
DISABLED
><
I88101NOV 17, 2020 2:09 PM
PORT SETTINGS:
COMM BOARD : 1 (RS-232) BAUD RATE : 9600
PARITY : ODD STOP BIT : 2 STOP
DATA LENGTH: 7 DATARS-232 SECURITY
CODE : DISABLED
><
I88102NOV 17, 2020 2:09 PM
PORT SETTINGS:
COMM BOARD : 2 (S-SAT ) BAUD RATE : 9600
PARITY : NONE STOP BIT : 1 STOP
DATA LENGTH: 8 DATARS-232 SECURITY
CODE : DISABLED DTR NORMAL STATE: HIGH
>
<I88103
NOV 17, 2020 2:09 PMPORT SETTINGS:
COMM BOARD : 3 (EDIM )
RS-232 SECURITYCODE : DISABLED
>
<
file:///C/Users/jerryr/Desktop/Riverlakes%20Monitor/Riverlakes%20setup.txt[12/4/2020 11:33:56 AM]
I60100
NOV 17, 2020 2:09 PM
TANK CONFIGURATION
DEVICE LABEL CONFIGURED 1 87 UNLEADED ON
2 91 PREMIUM ON 3 DIESEL ON
4 OFF
><
I60200NOV 17, 2020 2:09 PM
TANK PRODUCT LABEL
TANK PRODUCT LABEL
1 87 UNLEADED 2 91 PREMIUM
3 DIESEL 4
><
I60300NOV 17, 2020 2:09 PM
TANK PRODUCT CODE
TANK PRODUCT LABEL
1 87 UNLEADED 1 2 91 PREMIUM 2
3 DIESEL 3 4 4
><
I60900NOV 17, 2020 2:09 PM
TANK THERMAL COEFFICIENT
TANK PRODUCT LABEL
1 87 UNLEADED 0.000700 2 91 PREMIUM 0.000700
3 DIESEL 0.000045 4 0.000000
><
I60700NOV 17, 2020 2:09 PM
TANK DIAMETER
file:///C/Users/jerryr/Desktop/Riverlakes%20Monitor/Riverlakes%20setup.txt[12/4/2020 11:33:56 AM]
TANK PRODUCT LABEL INCHES
1 87 UNLEADED 120.00 2 91 PREMIUM 120.00
3 DIESEL 120.00 4 0.00
><
I60A00NOV 17, 2020 2:09 PM
TANK FULL VOLUME
TANK PRODUCT LABEL TANK PROFILE GALLONS
1 87 UNLEADED 4 PTS 21567
2 91 PREMIUM 4 PTS 8531
3 DIESEL 4 PTS 19951
4 1 PT 0
><
I60400NOV 17, 2020 2:10 PM
TANK FULL VOLUME
TANK PRODUCT LABEL GALLONS
1 87 UNLEADED 21567 2 91 PREMIUM 8531
3 DIESEL 19951 4 0
><
I60500NOV 17, 2020 2:10 PM
TANK 4 POINT VOLUMES
TANK PRODUCT LABEL GALLONS
1 87 UNLEADED 21567 17567 10858 4125 2 91 PREMIUM 8531 6888 4294 1692
3 DIESEL 19951 16262 10044 3804 4 0 0 0 0
>
<I60600
NOV 17, 2020 2:10 PM
TANK 20 POINT VOLUMES
file:///C/Users/jerryr/Desktop/Riverlakes%20Monitor/Riverlakes%20setup.txt[12/4/2020 11:33:56 AM]
TANK PRODUCT LABEL GALLONS 1 87 UNLEADED 21567 0 0 0
0 17567 0 0 0 0 10858 0
0 0 0 4125 0 0 0 0
2 91 PREMIUM 8531 0 0 0 0 6888 0 0
0 0 4294 0 0 0 0 1692
0 0 0 0 3 DIESEL 19951 0 0 0
0 16262 0 0 0 0 10044 0
0 0 0 3804 0 0 0 0
4 0 0 0 0 0 0 0 0
0 0 0 0 0 0 0 0
0 0 0 0
><
I61500NOV 17, 2020 2:10 PM
TANK PRODUCT LABEL METER DATA
1 87 UNLEADED NO 2 91 PREMIUM NO
3 DIESEL NO 4 NO
>
<I62F00
NOV 17, 2020 2:10 PM
MAG PROBE FLOAT SIZE
TANK PRODUCT LABEL FLOAT SIZE: 1 87 UNLEADED 4.0 IN.
2 91 PREMIUM 2.0 IN. 3 DIESEL 4.0 IN.
>
<I62700
NOV 17, 2020 2:10 PM
TANK HIGH WATER WARNING LIMIT
TANK PRODUCT LABEL INCHES
file:///C/Users/jerryr/Desktop/Riverlakes%20Monitor/Riverlakes%20setup.txt[12/4/2020 11:33:56 AM]
1 87 UNLEADED 1.5
2 91 PREMIUM 1.5 3 DIESEL 1.5
><
I64200NOV 17, 2020 2:10 PM
WATER ALARM FILTER
TANK PRODUCT LABEL
1 87 UNLEADED LOW 2 91 PREMIUM LOW
3 DIESEL LOW
><
I62400NOV 17, 2020 2:10 PM
TANK HIGH WATER LEVEL LIMIT
TANK PRODUCT LABEL INCHES
1 87 UNLEADED 2.0 2 91 PREMIUM 2.0
3 DIESEL 2.0>
<I62800
NOV 17, 2020 2:10 PM
TANK MAXIMUM VOLUME LIMIT
TANK PRODUCT LABEL GALLONS 1 87 UNLEADED 21567
2 91 PREMIUM 8531 3 DIESEL 19951
4 0>
<I62300
NOV 17, 2020 2:10 PM
TANK OVERFILL LEVEL LIMIT
TANK PRODUCT LABEL GALLONS 1 87 UNLEADED 19410
2 91 PREMIUM 7678 3 DIESEL 17956
4 0>
<I62200
NOV 17, 2020 2:10 PM
file:///C/Users/jerryr/Desktop/Riverlakes%20Monitor/Riverlakes%20setup.txt[12/4/2020 11:33:56 AM]
TANK HIGH PRODUCT LIMIT
TANK PRODUCT LABEL GALLONS 1 87 UNLEADED 20489
2 91 PREMIUM 8104 3 DIESEL 18953
4 0>
<I62900
NOV 17, 2020 2:10 PM
TANK DELIVERY REQUIRED LIMIT
TANK PRODUCT LABEL GALLONS 1 87 UNLEADED 2157
2 91 PREMIUM 853 3 DIESEL 1995
4 0>
<I62100
NOV 17, 2020 2:10 PM
TANK LOW PRODUCT LIMIT
TANK PRODUCT LABEL GALLONS 1 87 UNLEADED 1000
2 91 PREMIUM 500 3 DIESEL 1000
4 0>
<I62600
NOV 17, 2020 2:10 PM
TANK LEAK ALARM LIMIT
TANK PRODUCT LABEL GALLONS 1 87 UNLEADED 99
2 91 PREMIUM 99 3 DIESEL 99
4 99>
<I62500
NOV 17, 2020 2:11 PM
TANK SUDDEN LOSS LIMIT
TANK PRODUCT LABEL GALLONS 1 87 UNLEADED 99
2 91 PREMIUM 99
file:///C/Users/jerryr/Desktop/Riverlakes%20Monitor/Riverlakes%20setup.txt[12/4/2020 11:33:56 AM]
3 DIESEL 99
4 99>
<I60800
NOV 17, 2020 2:11 PM
TANK TILT
TANK PRODUCT LABEL INCHES 1 87 UNLEADED 0.00
2 91 PREMIUM 0.00 3 DIESEL 0.00
4 0.00>
<I60B00
NOV 17, 2020 2:11 PM
STICK HEIGHT OFFSET ENABLE STATUSDISABLED
>
<I60C00
NOV 17, 2020 2:11 PM
TANK STICK HEIGHT OFFSETTANK PRODUCT LABEL INCHES
1 87 UNLEADED 0.00 2 91 PREMIUM 0.00
3 DIESEL 0.00 4 0.00
><
I61200NOV 17, 2020 2:11 PM
TANK MANIFOLDED PARTNERS
TANK PRODUCT LABEL SIPHON MANIFOLDED TANKS LINE MANIFOLDED TANKS
1 87 UNLEADED NONE NONE 2 91 PREMIUM NONE NONE
3 DIESEL NONE NONE 4 NONE NONE
><
I63600NOV 17, 2020 2:11 PM
PERIODIC LEAK TEST MIN VOLUME
TANK PRODUCT LABEL GALLONS
1 87 UNLEADED 0
file:///C/Users/jerryr/Desktop/Riverlakes%20Monitor/Riverlakes%20setup.txt[12/4/2020 11:33:56 AM]
2 91 PREMIUM 0
3 DIESEL 0 4 0
><
I62A00NOV 17, 2020 2:11 PM
ANNUAL LEAK TEST MIN VOLUME
TANK PRODUCT LABEL GALLONS
1 87 UNLEADED 0 2 91 PREMIUM 0
3 DIESEL 0 4 0
><
I62C00NOV 17, 2020 2:11 PM
TANK PERIODIC TEST TYPE
TANK PRODUCT LABEL PERIODIC TEST TYPE
1 87 UNLEADED STANDARD 2 91 PREMIUM STANDARD
3 DIESEL STANDARD 4 STANDARD
>
<I62D00
NOV 17, 2020 2:11 PM
TANK LEAK TEST FAIL ALARMS
TANK PRODUCT LABEL 1 87 UNLEADED GROSS TEST FAIL ALARM DISABLED
PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED
2 91 PREMIUM GROSS TEST FAIL ALARM DISABLED
PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED
3 DIESEL GROSS TEST FAIL ALARM DISABLED
PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED
4 GROSS TEST FAIL ALARM DISABLED
PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED
>
file:///C/Users/jerryr/Desktop/Riverlakes%20Monitor/Riverlakes%20setup.txt[12/4/2020 11:33:56 AM]
<
I63100NOV 17, 2020 2:11 PM
TANK LEAK TEST AVERAGING
TANK PRODUCT LABEL ANNUAL PERIODIC
1 87 UNLEADED OFF OFF 2 91 PREMIUM OFF OFF
3 DIESEL OFF OFF 4 OFF OFF
>
<I63000
NOV 17, 2020 2:11 PM
IN-TANK LEAK TEST NOTIFY
TANK PRODUCT LABEL TANK TEST NOTIFY: 1 87 UNLEADED OFF
2 91 PREMIUM OFF 3 DIESEL OFF
4 OFF
><
I63200NOV 17, 2020 2:11 PM
TANK TEST SIPHON BREAK
TANK PRODUCT LABEL SIPHON BREAK
1 87 UNLEADED OFF 2 91 PREMIUM OFF
3 DIESEL OFF 4 OFF
>
<I61000
NOV 17, 2020 2:11 PM
TANK DELIVERY DELAY
TANK PRODUCT LABEL 1 87 UNLEADED 5
2 91 PREMIUM 5 3 DIESEL 5
4 1>
<I63A00
NOV 17, 2020 2:11 PM
file:///C/Users/jerryr/Desktop/Riverlakes%20Monitor/Riverlakes%20setup.txt[12/4/2020 11:33:56 AM]
LOW LEVEL PUMP THRESHOLD FOR SEQUENTIAL LINE MANIFOLD
TANK PRODUCT LABEL PUMP THRESHOLD 1 87 UNLEADED 10.00%
2 91 PREMIUM 10.00% 3 DIESEL 10.00%
4 10.00%
><
I61100NOV 17, 2020 2:11 PM
LEAK TEST METHOD
- - - - - - - - - - - -TEST ON DATE : ALL TANK
AUG 27, 2018START TIME : DISABLED
TEST RATE :0.20 GAL/HRDURATION : 2 HOURS
TST EARLY STOP:DISABLED
>
<I61300
NOV 17, 2020 2:12 PMCSLD PROBABLITY OF DETECTION
><
I61400NOV 17, 2020 2:12 PM
CSLD CLIMATE FACTOR
>
<I61600
NOV 17, 2020 2:12 PM
TANK PRODUCT LABEL CAL UPDATE 1 87 UNLEADED IMMEDIATE
2 91 PREMIUM IMMEDIATE 3 DIESEL IMMEDIATE
4 IMMEDIATE
><
I61A00NOV 17, 2020 2:12 PM
file:///C/Users/jerryr/Desktop/Riverlakes%20Monitor/Riverlakes%20setup.txt[12/4/2020 11:33:56 AM]
IN-TANK LEAK TEST EARLY STOP
TANK PRODUCT LABEL TST EARLY STOP:
1 87 UNLEADED DISABLED 2 91 PREMIUM DISABLED
3 DIESEL DISABLED 4 DISABLED
><
I61B00NOV 17, 2020 2:12 PM
IN-TANK LEAK GROSS TEST AUTO-CONFIRM
><
I61C00NOV 17, 2020 2:12 PM
CSLD REPORT ONLY
><
I63400NOV 17, 2020 2:12 PM
RECONCILIATION WARNING LIMIT
TANK PRODUCT LABEL GALLONS
1 87 UNLEADED 0 2 91 PREMIUM 0
3 DIESEL 0 4 0
><
I63500NOV 17, 2020 2:12 PM
RECONCILIATION ALARM LIMIT
TANK PRODUCT LABEL GALLONS
1 87 UNLEADED 1 2 91 PREMIUM 1
3 DIESEL 1 4 1
><
I78700NOV 17, 2020 2:12 PM
>
<
file:///C/Users/jerryr/Desktop/Riverlakes%20Monitor/Riverlakes%20setup.txt[12/4/2020 11:33:56 AM]
I70200
NOV 17, 2020 2:12 PM
LIQUID LABEL
DEVICE LABEL 1 87 STP
2 87 FILL 3 91 STP
4 91 FILL 5 DIESEL STP
6 DIESEL FILL 7 UNLEADED ANNULAR
8 DIESEL ANNULAR 9 1-2 UDC
10 3-4 UDC 11 5-6 UDC
12 7-8 UDC 13 VENT BOX
14 15
16
><
I70300NOV 17, 2020 2:12 PM
LIQUID TYPE
SENSOR LOCATION TYPE
1 87 STP DW SUMP 2-1 2 87 FILL DW SUMP 2-1
3 91 STP DW SUMP 2-1 4 91 FILL DW SUMP 2-1
5 DIESEL STP DW SUMP 2-1 6 DIESEL FILL DW SUMP 2-1
7 UNLEADED ANNULAR DUAL POINT HYDROSTATIC 8 DIESEL ANNULAR DUAL POINT HYDROSTATIC
9 1-2 UDC DW SUMP 2-1 10 3-4 UDC DW SUMP 2-1
11 5-6 UDC DW SUMP 2-1 12 7-8 UDC DW SUMP 2-1
13 VENT BOX DW SUMP 2-1 14 TRI-STATE (SINGLE FLOAT)
15 TRI-STATE (SINGLE FLOAT) 16 TRI-STATE (SINGLE FLOAT)
>
<I70400
NOV 17, 2020 2:12 PM
LIQUID CATEGORY
file:///C/Users/jerryr/Desktop/Riverlakes%20Monitor/Riverlakes%20setup.txt[12/4/2020 11:33:56 AM]
SENSOR LOCATION CATEGORY
1 87 STP STP SUMP 2 87 FILL PIPING SUMP
3 91 STP STP SUMP 4 91 FILL PIPING SUMP
5 DIESEL STP STP SUMP 6 DIESEL FILL PIPING SUMP
7 UNLEADED ANNULAR ANNULAR SPACE 8 DIESEL ANNULAR ANNULAR SPACE
9 1-2 UDC DISPENSER PAN 10 3-4 UDC DISPENSER PAN
11 5-6 UDC DISPENSER PAN 12 7-8 UDC DISPENSER PAN
13 VENT BOX OTHER SENSORS 14 OTHER SENSORS
15 OTHER SENSORS 16 OTHER SENSORS
>
<I80700
NOV 17, 2020 2:12 PM
RELAY LABEL
DEVICE LABEL 1 87 STP
2 91 STP 3 DIESEL STP
4 TEST 5 DISP 1-2
6 DISP 3-4 7 DISP 5-6
8 DISP 7-8 9
10 11
12 OVERFILL
><
I80900NOV 17, 2020 2:13 PM
RELAY ORIENTATION
RELAY DESIGNATION ORIENTATION
1 87 STP NORMALLY OPEN 2 91 STP NORMALLY OPEN
3 DIESEL STP NORMALLY OPEN 4 TEST NORMALLY OPEN
5 DISP 1-2 NORMALLY OPEN 6 DISP 3-4 NORMALLY OPEN
file:///C/Users/jerryr/Desktop/Riverlakes%20Monitor/Riverlakes%20setup.txt[12/4/2020 11:33:56 AM]
7 DISP 5-6 NORMALLY OPEN
8 DISP 7-8 NORMALLY OPEN 9 NORMALLY OPEN
10 NORMALLY OPEN 11 NORMALLY OPEN
12 OVERFILL NORMALLY OPEN
><
I80B00NOV 17, 2020 2:13 PM
RELAY TANK ASSIGNMENT
RELAY DESIGNATION TANK
1 87 STP 1 2 91 STP 2
3 DIESEL STP 3 4 TEST NONE
5 DISP 1-2 NONE 6 DISP 3-4 NONE
7 DISP 5-6 NONE 8 DISP 7-8 NONE
9 NONE 10 NONE
11 NONE 12 OVERFILL NONE
>
<I80A00
NOV 17, 2020 2:13 PM
RELAY TYPE
RELAY DESIGNATION TYPE 1 87 STP PUMP CONTROL OUTPUT
2 91 STP PUMP CONTROL OUTPUT 3 DIESEL STP PUMP CONTROL OUTPUT
4 TEST STANDARD 5 DISP 1-2 STANDARD
6 DISP 3-4 STANDARD 7 DISP 5-6 STANDARD
8 DISP 7-8 STANDARD 9 STANDARD
10 STANDARD 11 STANDARD
12 OVERFILL STANDARD
><
I80800NOV 17, 2020 2:13 PM
file:///C/Users/jerryr/Desktop/Riverlakes%20Monitor/Riverlakes%20setup.txt[12/4/2020 11:33:56 AM]
RELAY SETUP REPORT
R 1:87 STP
TYPE: PUMP CONTROL OUTPUT
TANK #: 1
IN-TANK ALARMS
T 1:LOW PRODUCT ALARM
LIQUID SENSOR ALMS L 1:FUEL ALARM
L 9:FUEL ALARM L10:FUEL ALARM
L11:FUEL ALARM L12:FUEL ALARM
L 1:SENSOR OUT ALARM L 9:SENSOR OUT ALARM
L10:SENSOR OUT ALARM L11:SENSOR OUT ALARM
L12:SENSOR OUT ALARM L 1:SHORT ALARM
L 9:SHORT ALARM L10:SHORT ALARM
L11:SHORT ALARM L12:SHORT ALARM
ISD SITE ALARMS
ISD GROSS PRES FAIL ISD DEGRD PRES FAIL
ISD VAPOR LEAK FAIL
ISD HOSE ALARMS ALL:FLOW COLLECT FAIL
R 2:91 STP TYPE:
PUMP CONTROL OUTPUTTANK #: 2
IN-TANK ALARMS T 2:LOW PRODUCT ALARM
LIQUID SENSOR ALMS
L 3:FUEL ALARM L 9:FUEL ALARM
L10:FUEL ALARM L11:FUEL ALARM
L12:FUEL ALARM L 3:SENSOR OUT ALARM
L 9:SENSOR OUT ALARM
file:///C/Users/jerryr/Desktop/Riverlakes%20Monitor/Riverlakes%20setup.txt[12/4/2020 11:33:56 AM]
L10:SENSOR OUT ALARM
L11:SENSOR OUT ALARM L12:SENSOR OUT ALARM
L 3:SHORT ALARM L 9:SHORT ALARM
L10:SHORT ALARM L11:SHORT ALARM
L12:SHORT ALARM
ISD SITE ALARMS ISD GROSS PRES FAIL
ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL
ISD HOSE ALARMS
ALL:FLOW COLLECT FAIL
R 3:DIESEL STP
TYPE: PUMP CONTROL OUTPUT
TANK #: 3
IN-TANK ALARMS
T 3:LOW PRODUCT ALARM
LIQUID SENSOR ALMS L 5:FUEL ALARM
L 9:FUEL ALARM L10:FUEL ALARM
L11:FUEL ALARM L12:FUEL ALARM
L 5:SENSOR OUT ALARM L 9:SENSOR OUT ALARM
L10:SENSOR OUT ALARM L11:SENSOR OUT ALARM
L12:SENSOR OUT ALARM L 5:SHORT ALARM
L 9:SHORT ALARM L10:SHORT ALARM
L11:SHORT ALARM L12:SHORT ALARM
R 4:TEST TYPE:
STANDARDNORMALLY OPEN
TANK #: NONE
- NO ALARM ASSIGNMENTS -
file:///C/Users/jerryr/Desktop/Riverlakes%20Monitor/Riverlakes%20setup.txt[12/4/2020 11:33:56 AM]
R 5:DISP 1-2
TYPE: STANDARD
NORMALLY OPEN
TANK #: NONE
- NO ALARM ASSIGNMENTS -
R 6:DISP 3-4 TYPE:
STANDARDNORMALLY OPEN
TANK #: NONE
- NO ALARM ASSIGNMENTS -
R 7:DISP 5-6
TYPE: STANDARD
NORMALLY OPEN
TANK #: NONE
- NO ALARM ASSIGNMENTS -
R 8:DISP 7-8 TYPE:
STANDARDNORMALLY OPEN
TANK #: NONE
- NO ALARM ASSIGNMENTS -
R 9:
TYPE: STANDARD
NORMALLY OPEN
TANK #: NONE
- NO ALARM ASSIGNMENTS -
R10: TYPE:
STANDARDNORMALLY OPEN
TANK #: NONE
- NO ALARM ASSIGNMENTS -
file:///C/Users/jerryr/Desktop/Riverlakes%20Monitor/Riverlakes%20setup.txt[12/4/2020 11:33:56 AM]
R11:
TYPE: STANDARD
NORMALLY OPEN
TANK #: NONE
- NO ALARM ASSIGNMENTS -
R12:OVERFILL TYPE:
STANDARDNORMALLY OPEN
TANK #: NONE
IN-TANK ALARMS ALL:OVERFILL ALARM
ALL:HIGH PRODUCT ALARM
><I79000
NOV 17, 2020 2:14 PM
EDIM:1 VR:349643-001-B TD:97.10.27.11.25
><
I72300NOV 17, 2020 2:14 PM
BROOKSIDE MARKET
4700 COFFEE RD BAKERSFIELD CA 93308
661-588-1338
SMARTSENSOR ASSIGNMENT DEVICE LABEL CATEGORY
01 87 PRODUCT VAC SENSOR02 UNKNOWN
03 VAPOR RETURN VAC SENSOR04 91 PRODUCT VAC SENSOR
05 ALL VENTS VAC SENSOR06 DIESEL PRODUCT VAC SENSOR
07 UNKNOWN08 ATM ATM P SENSOR
09 1-2 FLOWMETER AIR FLOW METER10 3-4 FLOWMETER AIR FLOW METER
11 5-6 FLOWMETER AIR FLOW METER
file:///C/Users/jerryr/Desktop/Riverlakes%20Monitor/Riverlakes%20setup.txt[12/4/2020 11:33:56 AM]
12 7-8 FLOWMETER AIR FLOW METER
13 UNKNOWN14 UNKNOWN
15 UNKNOWN16 PRESSURE SENSOR VAPOR PRESSURE
17 UNKNOWN18 UNKNOWN
19 UNKNOWN20 UNKNOWN
21 UNKNOWN22 UNKNOWN
23 UNKNOWN24 UNKNOWN
25 UNKNOWN26 UNKNOWN
27 UNKNOWN28 UNKNOWN
29 UNKNOWN30 UNKNOWN
31 UNKNOWN32 UNKNOWN
33 UNKNOWN34 UNKNOWN
35 UNKNOWN36 UNKNOWN
37 UNKNOWN38 UNKNOWN
39 UNKNOWN40 UNKNOWN
>
<IV4F00
NOV 17, 2020 2:14 PM
BROOKSIDE MARKET 4700 COFFEE RD
BAKERSFIELD CA 93308661-588-1338
NOZZLE A/L RANGE
A/L RATIO: 0.95 - 1.15
><
IV4000NOV 17, 2020 2:14 PM
BROOKSIDE MARKET
4700 COFFEE RD BAKERSFIELD CA 93308
661-588-1338
VAPOR PROCESSOR TYPE
file:///C/Users/jerryr/Desktop/Riverlakes%20Monitor/Riverlakes%20setup.txt[12/4/2020 11:33:56 AM]
NONE
>
<IV4700
NOV 17, 2020 2:14 PM
BROOKSIDE MARKET 4700 COFFEE RD
BAKERSFIELD CA 93308661-588-1338
ASSESSMENT TIME
START TIME: 9:00 AMTIME DELAY MINUTES: 1
>
<IV5200
NOV 17, 2020 2:14 PM
BROOKSIDE MARKET 4700 COFFEE RD
BAKERSFIELD CA 93308661-588-1338
ACCEPT HIGH ORVR: NO
><
IV4A00NOV 17, 2020 2:14 PM
BROOKSIDE MARKET
4700 COFFEE RD BAKERSFIELD CA 93308
661-588-1338
ISD HOSE TABLE
HOSE FP FP AFM REL HOSE ID ID LABEL ID ID LABEL
01 01 01 01 02 BLEND3 02 02 02 01 02 BLEND3
03 03 03 02 02 BLEND3 04 04 04 02 02 BLEND3
05 05 05 03 02 BLEND3 06 06 06 03 02 BLEND3
07 07 07 04 02 BLEND3 08 08 08 04 02 BLEND3
>
<IV4B00
NOV 17, 2020 2:14 PM
file:///C/Users/jerryr/Desktop/Riverlakes%20Monitor/Riverlakes%20setup.txt[12/4/2020 11:33:56 AM]
BROOKSIDE MARKET 4700 COFFEE RD
BAKERSFIELD CA 93308661-588-1338
PRODUCT/HOSE MAP TABLE
FP AFID M1/H1 M2/H2 M3/H3 M4/H4
01 01 xx/xx 02/01 01/01 xx/xx02 01 02/02 xx/xx 09/02 01/02
03 02 02/03 09/03 01/03 xx/xx04 02 02/04 01/04 09/04 xx/xx
05 03 02/05 01/05 09/05 xx/xx06 03 02/06 09/06 01/06 xx/xx
07 04 02/07 01/07 09/07 xx/xx08 04 02/08 01/08 xx/xx 09/08
>
<IV4900
NOV 17, 2020 2:14 PM
BROOKSIDE MARKET 4700 COFFEE RD
BAKERSFIELD CA 93308661-588-1338
LABEL TABLE
ID LABEL01 UNASSIGNED
02 BLEND3 03 REGULAR
04 MID GRADE 05 PREMIUM
06 GOLD 07 BRONZE
08 SILVER 09 BLEND2
10 BLEND4
><
IV1000NOV 17, 2020 2:14 PM
ISD VERSION: 01.05
>
<I90200
NOV 17, 2020 2:14 PMSOFTWARE REVISION LEVEL
VERSION 335.00
file:///C/Users/jerryr/Desktop/Riverlakes%20Monitor/Riverlakes%20setup.txt[12/4/2020 11:33:56 AM]
SOFTWARE# 346335-100-A
CREATED - 18.08.27.10.22
S-MODULE# 330160-004-aSYSTEM FEATURES:
PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS
ISD/APM
><
I11100NOV 17, 2020 2:14 PM
BROOKSIDE MARKET
4700 COFFEE RD BAKERSFIELD CA 93308
661-588-1338
PRIORITY ALARM HISTORYID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME
L 5 STP SUMP DIESEL STP LOW LIQUID ALARM CLEAR 11-17-20 12:23PML 5 STP SUMP DIESEL STP LOW LIQUID ALARM ALARM 11-17-20 12:23PM
L 5 STP SUMP DIESEL STP LOW LIQUID ALARM CLEAR 11-17-20 12:23PML 5 STP SUMP DIESEL STP LOW LIQUID ALARM ALARM 11-17-20 12:23PM
T 2 TANK 91 PREMIUM HIGH WATER ALARM CLEAR 11-17-20 12:15PMT 2 TANK 91 PREMIUM PROBE OUT CLEAR 11-17-20 12:12PM
T 1 TANK 87 UNLEADED PROBE OUT CLEAR 11-17-20 11:58AMT 1 TANK 87 UNLEADED PROBE OUT ALARM 11-17-20 11:57AM
T 3 TANK DIESEL PROBE OUT CLEAR 11-17-20 11:57AMT 2 TANK 91 PREMIUM PROBE OUT ALARM 11-17-20 11:57AM
T 3 TANK DIESEL PROBE OUT ALARM 11-17-20 11:56AMT 2 TANK 91 PREMIUM PROBE OUT CLEAR 11-17-20 11:56AM
T 2 TANK 91 PREMIUM PROBE OUT ALARM 11-17-20 11:55AMT 2 TANK 91 PREMIUM OVERFILL ALARM CLEAR 11-17-20 11:55AM
L 8 ANNULAR DIESEL ANNULAR HIGH LIQUID ALARM CLEAR 11-17-20 11:54AML 8 ANNULAR DIESEL ANNULAR HIGH LIQUID ALARM ALARM 11-17-20 11:54AM
L 8 ANNULAR DIESEL ANNULAR LOW LIQUID ALARM CLEAR 11-17-20 11:54AML 8 ANNULAR DIESEL ANNULAR LOW LIQUID ALARM ALARM 11-17-20 11:54AM
L 7 ANNULAR UNLEADED ANNULAR LOW LIQUID ALARM CLEAR 11-17-20 11:54AML 7 ANNULAR UNLEADED ANNULAR LOW LIQUID ALARM ALARM 11-17-20 11:54AM
L 7 ANNULAR UNLEADED ANNULAR HIGH LIQUID ALARM CLEAR 11-17-20 11:54AML 7 ANNULAR UNLEADED ANNULAR HIGH LIQUID ALARM ALARM 11-17-20 11:54AM
L 7 ANNULAR UNLEADED ANNULAR LOW LIQUID ALARM CLEAR 11-17-20 11:53AML 7 ANNULAR UNLEADED ANNULAR LOW LIQUID ALARM ALARM 11-17-20 11:53AM
T 2 TANK 91 PREMIUM HIGH WATER ALARM ALARM 11-17-20 11:52AMT 2 TANK 91 PREMIUM OVERFILL ALARM ALARM 11-17-20 11:49AM
T 2 TANK 91 PREMIUM MAX PRODUCT ALARM CLEAR 11-17-20 11:49AMT 2 TANK 91 PREMIUM MAX PRODUCT ALARM ALARM 11-17-20 11:49AM
T 1 TANK 87 UNLEADED OVERFILL ALARM CLEAR 11-17-20 11:35AML 6 PIPE DIESEL FILL SENSOR OUT ALARM CLEAR 11-17-20 11:35AM
L 2 PIPE 87 FILL SENSOR OUT ALARM CLEAR 11-17-20 11:35AML12 DISP PAN 7-8 UDC SENSOR OUT ALARM CLEAR 11-17-20 11:35AM
L 4 PIPE 91 FILL SENSOR OUT ALARM CLEAR 11-17-20 11:35AM
file:///C/Users/jerryr/Desktop/Riverlakes%20Monitor/Riverlakes%20setup.txt[12/4/2020 11:33:56 AM]
L 8 ANNULAR DIESEL ANNULAR SENSOR OUT ALARM CLEAR 11-17-20 11:35AM
L 1 STP SUMP 87 STP SENSOR OUT ALARM CLEAR 11-17-20 11:35AML 7 ANNULAR UNLEADED ANNULAR SENSOR OUT ALARM CLEAR 11-17-20 11:35AM
L 3 STP SUMP 91 STP SENSOR OUT ALARM CLEAR 11-17-20 11:35AML11 DISP PAN 5-6 UDC SENSOR OUT ALARM CLEAR 11-17-20 11:35AM
L 5 STP SUMP DIESEL STP SENSOR OUT ALARM CLEAR 11-17-20 11:35AML10 DISP PAN 3-4 UDC SENSOR OUT ALARM CLEAR 11-17-20 11:35AM
L 9 DISP PAN 1-2 UDC SENSOR OUT ALARM CLEAR 11-17-20 11:35AML13 OTHER VENT BOX SENSOR OUT ALARM CLEAR 11-17-20 11:34AM
L13 OTHER VENT BOX SENSOR OUT ALARM ALARM 11-17-20 11:34AML12 DISP PAN 7-8 UDC SENSOR OUT ALARM ALARM 11-17-20 11:34AM
L 4 PIPE 91 FILL SENSOR OUT ALARM ALARM 11-17-20 11:34AML11 DISP PAN 5-6 UDC SENSOR OUT ALARM ALARM 11-17-20 11:34AM
L10 DISP PAN 3-4 UDC SENSOR OUT ALARM ALARM 11-17-20 11:34AML 8 ANNULAR DIESEL ANNULAR SENSOR OUT ALARM ALARM 11-17-20 11:34AM
L 2 PIPE 87 FILL SENSOR OUT ALARM ALARM 11-17-20 11:34AML 7 ANNULAR UNLEADED ANNULAR SENSOR OUT ALARM ALARM 11-17-20 11:34AM
>
<I11200
NOV 17, 2020 2:14 PM
BROOKSIDE MARKET 4700 COFFEE RD
BAKERSFIELD CA 93308661-588-1338
NON-PRIORITY ALARM HISTORY
ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIMET 2 TANK 91 PREMIUM HIGH WATER WARNING CLEAR 11-17-20 12:15PM
T 2 TANK 91 PREMIUM LOW TEMP WARNING CLEAR 11-17-20 12:12PMT 2 TANK 91 PREMIUM LOW TEMP WARNING ALARM 11-17-20 12:12PM
T 1 TANK 87 UNLEADED LOW TEMP WARNING CLEAR 11-17-20 12:00PMT 1 TANK 87 UNLEADED LOW TEMP WARNING ALARM 11-17-20 11:58AM
T 2 TANK 91 PREMIUM HIGH WATER WARNING ALARM 11-17-20 11:52AMT 2 TANK 91 PREMIUM HIGH PRODUCT ALARM CLEAR 11-17-20 11:49AM
T 2 TANK 91 PREMIUM HIGH PRODUCT ALARM ALARM 11-17-20 11:49AMT 1 TANK 87 UNLEADED HIGH PRODUCT ALARM CLEAR 11-17-20 11:31AM
T 1 TANK 87 UNLEADED HIGH PRODUCT ALARM ALARM 11-17-20 11:29AMT 2 TANK 91 PREMIUM DELIVERY NEEDED CLEAR 11-17-20 11:22AM
T 2 TANK 91 PREMIUM DELIVERY NEEDED ALARM 11-17-20 11:22AMT 3 TANK DIESEL DELIVERY NEEDED CLEAR 11-17-20 11:22AM
T 3 TANK DIESEL DELIVERY NEEDED ALARM 11-17-20 11:21AM SYSTEM PAPER OUT CLEAR 11-17-20 11:17AM
SYSTEM PAPER OUT ALARM 11-17-20 11:17AM SYSTEM PAPER OUT CLEAR 11-17-20 11:16AM
SYSTEM PAPER OUT ALARM 11-17-20 11:15AMs 5 OTHER ALL VENTS VACUUM WARNING CLEAR 9-10-20 11:44AM
s 5 OTHER ALL VENTS VACUUM WARNING ALARM 9-10-20 11:24AMs 5 OTHER ALL VENTS VACUUM WARNING CLEAR 9-10-20 10:37AM
s 5 OTHER ALL VENTS VACUUM WARNING ALARM 9-10-20 10:36AMs 5 OTHER ALL VENTS VACUUM WARNING CLEAR 9-04-20 2:23PM
s 5 OTHER ALL VENTS VACUUM WARNING ALARM 9-04-20 1:28PM
file:///C/Users/jerryr/Desktop/Riverlakes%20Monitor/Riverlakes%20setup.txt[12/4/2020 11:33:56 AM]
SYSTEM PAPER OUT CLEAR 7-03-20 5:12AM
SYSTEM PAPER OUT ALARM 7-02-20 2:04PM SYSTEM PRINTER ERROR CLEAR 6-30-20 4:54PM
SYSTEM PRINTER ERROR ALARM 6-30-20 4:54PM OTHER ISD VAPOR LEAK WARN CLEAR 5-06-20 2:01PM
SYSTEM PAPER OUT CLEAR 5-06-20 9:09AM SYSTEM PRINTER ERROR CLEAR 5-06-20 9:09AM
SYSTEM PRINTER ERROR ALARM 5-06-20 9:09AM SYSTEM PAPER OUT ALARM 5-06-20 9:06AM
OTHER ISD VAPOR LEAK WARN ALARM 5-06-20 9:06AMT 3 TANK DIESEL DELIVERY NEEDED CLEAR 4-30-20 3:41PM
T 3 TANK DIESEL DELIVERY NEEDED ALARM 4-29-20 2:55PM SYSTEM PRINTER ERROR CLEAR 4-15-20 11:10AM
SYSTEM PRINTER ERROR ALARM 4-15-20 11:10AM SYSTEM PAPER OUT CLEAR 3-11-20 11:26AM
SYSTEM PAPER OUT ALARM 3-11-20 11:25AM SYSTEM PRINTER ERROR CLEAR 2-01-20 8:10AM
SYSTEM PRINTER ERROR ALARM 2-01-20 8:10AM SYSTEM PAPER OUT CLEAR 1-30-20 5:10AM
SYSTEM PRINTER ERROR CLEAR 1-30-20 5:06AM SYSTEM PRINTER ERROR ALARM 1-30-20 5:06AM
SYSTEM PAPER OUT ALARM 1-29-20 3:42AM SYSTEM PAPER OUT CLEAR 12-05-19 7:19AM
SYSTEM PAPER OUT ALARM 12-05-19 1:00AM OTHER ISD VAPOR LEAK WARN CLEAR 11-15-19 2:39PM
OTHER ISD VAPOR LEAK WARN ALARM 11-15-19 9:02AM
><
I20600NOV 17, 2020 2:15 PM
BROOKSIDE MARKET
4700 COFFEE RD BAKERSFIELD CA 93308
661-588-1338
TANK ALARM HISTORY
TANK 1 87 UNLEADED
SETUP DATA WARNING OCT 9, 2019 2:20 PM
HIGH WATER ALARM OCT 10, 2019 7:39 AM
OVERFILL ALARM NOV 17, 2020 11:29 AM
OCT 10, 2019 11:45 AM
LOW PRODUCT ALARM OCT 10, 2019 7:35 AM OCT 9, 2019 2:18 PM
HIGH PRODUCT ALARM NOV 17, 2020 11:29 AM
OCT 10, 2019 11:54 AM
file:///C/Users/jerryr/Desktop/Riverlakes%20Monitor/Riverlakes%20setup.txt[12/4/2020 11:33:56 AM]
PROBE OUT NOV 17, 2020 11:57 AM NOV 17, 2020 11:23 AM
OCT 10, 2019 12:21 PM
HIGH WATER WARNING OCT 10, 2019 7:39 AM
DELIVERY NEEDED OCT 10, 2019 7:35 AM OCT 9, 2019 2:18 PM
MAX PRODUCT ALARM NOV 17, 2020 11:30 AM
LOW TEMP WARNING NOV 17, 2020 11:58 AM
OCT 10, 2019 12:22 PM
TANK 2 91 PREMIUM
SETUP DATA WARNING OCT 9, 2019 2:20 PM
HIGH WATER ALARM NOV 17, 2020 11:52 AM OCT 9, 2019 3:09 PM
OCT 9, 2019 2:24 PM
OVERFILL ALARM NOV 17, 2020 11:49 AM JAN 29, 2020 3:42 AM
OCT 10, 2019 12:04 PM
LOW PRODUCT ALARM NOV 17, 2020 11:22 AM OCT 9, 2019 2:40 PM
SUDDEN LOSS ALARM NOV 17, 2020 11:23 AM
HIGH PRODUCT ALARM NOV 17, 2020 11:49 AM
OCT 9, 2019 2:18 PM
PROBE OUT NOV 17, 2020 11:57 AM NOV 17, 2020 11:55 AM
NOV 17, 2020 11:23 AM
HIGH WATER WARNING NOV 17, 2020 11:52 AM OCT 9, 2019 3:09 PM
OCT 9, 2019 2:24 PM
DELIVERY NEEDED NOV 17, 2020 11:22 AM OCT 9, 2019 2:40 PM
MAX PRODUCT ALARM NOV 17, 2020 11:49 AM
OCT 9, 2019 2:18 PM
LOW TEMP WARNING NOV 17, 2020 12:12 PM
TANK 3 DIESEL
SETUP DATA WARNING AUG 27, 2018 8:19 AM
file:///C/Users/jerryr/Desktop/Riverlakes%20Monitor/Riverlakes%20setup.txt[12/4/2020 11:33:56 AM]
HIGH WATER ALARM OCT 10, 2019 8:36 AM
OCT 10, 2019 7:37 AM
OVERFILL ALARM NOV 17, 2020 11:27 AM OCT 10, 2019 11:41 AM
OCT 10, 2019 8:33 AM
LOW PRODUCT ALARM OCT 10, 2019 7:33 AM AUG 27, 2018 8:05 AM
HIGH PRODUCT ALARM OCT 10, 2019 11:41 AM
OCT 10, 2019 7:52 AM
INVALID FUEL LEVEL AUG 27, 2018 8:05 AM
PROBE OUT NOV 17, 2020 11:56 AM NOV 17, 2020 11:21 AM
OCT 10, 2019 12:20 PM
HIGH WATER WARNING OCT 10, 2019 7:56 AM OCT 10, 2019 7:37 AM
DELIVERY NEEDED NOV 17, 2020 11:21 AM
APR 29, 2020 2:55 PM OCT 10, 2019 7:33 AM
LOW TEMP WARNING OCT 10, 2019 12:21 PM
TANK 5
TANK 6
TANK 7
TANK 8
TANK 9
TANK 10
TANK 11
TANK 12
TANK 13
TANK 14
TANK 15
TANK 16
file:///C/Users/jerryr/Desktop/Riverlakes%20Monitor/Riverlakes%20setup.txt[12/4/2020 11:33:56 AM]
>
<I38200
NOV 17, 2020 2:15 PM
><
I30200NOV 17, 2020 2:15 PM
BROOKSIDE MARKET
4700 COFFEE RD BAKERSFIELD CA 93308
661-588-1338
LIQUID ALARM HISTORY REPORT
SENSOR LOCATION 1 87 STP
NOV 17, 2020 11:34 AM SENSOR OUT ALARM NOV 17, 2020 10:43 AM FUEL ALARM
NOV 17, 2020 10:19 AM LOW LIQUID ALARM 2 87 FILL
NOV 17, 2020 11:34 AM SENSOR OUT ALARM NOV 17, 2020 10:54 AM FUEL ALARM
NOV 17, 2020 10:20 AM LOW LIQUID ALARM 3 91 STP
NOV 17, 2020 11:34 AM SENSOR OUT ALARM NOV 17, 2020 10:44 AM FUEL ALARM
NOV 17, 2020 10:20 AM LOW LIQUID ALARM 4 91 FILL
NOV 17, 2020 11:34 AM SENSOR OUT ALARM NOV 17, 2020 10:49 AM FUEL ALARM
NOV 17, 2020 10:20 AM LOW LIQUID ALARM 5 DIESEL STP
NOV 17, 2020 12:23 PM LOW LIQUID ALARM NOV 17, 2020 12:23 PM LOW LIQUID ALARM
NOV 17, 2020 11:34 AM SENSOR OUT ALARM 6 DIESEL FILL
NOV 17, 2020 11:34 AM SENSOR OUT ALARM NOV 17, 2020 10:49 AM FUEL ALARM
NOV 17, 2020 10:20 AM LOW LIQUID ALARM 7 UNLEADED ANNULAR
NOV 17, 2020 11:54 AM LOW LIQUID ALARM NOV 17, 2020 11:54 AM HIGH LIQUID ALARM
NOV 17, 2020 11:53 AM LOW LIQUID ALARM 8 DIESEL ANNULAR
NOV 17, 2020 11:54 AM HIGH LIQUID ALARM NOV 17, 2020 11:54 AM LOW LIQUID ALARM
NOV 17, 2020 11:34 AM SENSOR OUT ALARM 9 1-2 UDC
NOV 17, 2020 11:34 AM SENSOR OUT ALARM NOV 17, 2020 10:29 AM FUEL ALARM
NOV 17, 2020 10:21 AM LOW LIQUID ALARM
file:///C/Users/jerryr/Desktop/Riverlakes%20Monitor/Riverlakes%20setup.txt[12/4/2020 11:33:56 AM]
10 3-4 UDC
NOV 17, 2020 11:34 AM SENSOR OUT ALARM NOV 17, 2020 10:33 AM FUEL ALARM
NOV 17, 2020 10:21 AM LOW LIQUID ALARM 11 5-6 UDC
NOV 17, 2020 11:34 AM SENSOR OUT ALARM NOV 17, 2020 10:36 AM FUEL ALARM
NOV 17, 2020 10:21 AM LOW LIQUID ALARM 12 7-8 UDC
NOV 17, 2020 11:34 AM SENSOR OUT ALARM NOV 17, 2020 10:39 AM FUEL ALARM
NOV 17, 2020 10:21 AM LOW LIQUID ALARM 13 VENT BOX
NOV 17, 2020 11:34 AM SENSOR OUT ALARM NOV 17, 2020 10:49 AM FUEL ALARM
NOV 17, 2020 10:20 AM LOW LIQUID ALARM
><
I31600NOV 17, 2020 2:15 PM
BROOKSIDE MARKET
4700 COFFEE RD BAKERSFIELD CA 93308
661-588-1338
SMART SENSOR ALARM HISTORY REPORT
SENSOR LOCATION 1 87 PRODUCT
NOV 17, 2020 11:11 AM HIGH LIQUID ALARM NOV 17, 2020 11:10 AM NO VACUUM ALARM
OCT 10, 2019 12:06 PM HIGH LIQUID ALARM 3 VAPOR RETURN
NOV 17, 2020 11:17 AM HIGH LIQUID ALARM NOV 17, 2020 11:17 AM NO VACUUM ALARM
OCT 10, 2019 12:06 PM HIGH LIQUID ALARM 4 91 PRODUCT
NOV 17, 2020 11:06 AM HIGH LIQUID ALARM NOV 17, 2020 11:05 AM NO VACUUM ALARM
SEP 4, 2020 9:20 AM NO VACUUM ALARM 5 ALL VENTS
NOV 17, 2020 11:09 AM HIGH LIQUID ALARM SEP 10, 2020 11:24 AM VACUUM WARNING
SEP 10, 2020 10:37 AM NO VACUUM ALARM 6 DIESEL PRODUCT
NOV 17, 2020 11:19 AM HIGH LIQUID ALARM NOV 17, 2020 11:19 AM NO VACUUM ALARM
OCT 10, 2019 12:07 PM HIGH LIQUID ALARM 8 ATM
9 1-2 FLOWMETER AUG 27, 2018 9:34 AM COMMUNICATION ALARM
10 3-4 FLOWMETER
file:///C/Users/jerryr/Desktop/Riverlakes%20Monitor/Riverlakes%20setup.txt[12/4/2020 11:33:56 AM]
AUG 27, 2018 9:34 AM COMMUNICATION ALARM
11 5-6 FLOWMETER AUG 27, 2018 9:34 AM COMMUNICATION ALARM
12 7-8 FLOWMETER AUG 27, 2018 9:34 AM COMMUNICATION ALARM
16 PRESSURE SENSOR AUG 27, 2018 9:34 AM COMMUNICATION ALARM
>
<I10200
NOV 17, 2020 2:15 PM
BROOKSIDE MARKET 4700 COFFEE RD
BAKERSFIELD CA 93308661-588-1338
SYSTEM CONFIGURATION
SLOT BOARD TYPE POWER ON RESET CURRENT
1 UNUSED 4952047 4931112 2 UNUSED 4939418 4929592
3 4 PROBE / G.T. 165562 165527 4 INTERSTITIAL BD 204254 203985
5 INTERSTITIAL BD 204109 203791 6 7SMARTSENSOR BD 516304 516154
7 8SMARTSENSOR BD 39981 39950 8 UNUSED 4932980 4924157
9 RELAY BOARD 15141 15119 10 RELAY BOARD 15141 15142
11 RELAY BOARD 15163 15142 12 STP SENSE BOARD 33612 33593
13 UNUSED 4942637 4931262 14 UNUSED 4938220 4926275
15 UNUSED 4936444 4927595 16 UNUSED 4938753 4924017
COMM 1 RS232 SERIAL BD 15186 15164 COMM 2 SERIAL SAT BD 488306 487493
COMM 3 ELEC DISP INT. 102294 102312 COMM 4 UNUSED 4940528 4928333
COMM 5 RS485 MODBUS BD 84872 84735 COMM 6 RS232 SERIAL BD 15208 15187
>
<I90200
NOV 17, 2020 2:15 PMSOFTWARE REVISION LEVEL
VERSION 335.00SOFTWARE# 346335-100-A
CREATED - 18.08.27.10.22
S-MODULE# 330160-004-a
file:///C/Users/jerryr/Desktop/Riverlakes%20Monitor/Riverlakes%20setup.txt[12/4/2020 11:33:56 AM]
SYSTEM FEATURES:
PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS
ISD/APM
>