Hazardous Waste Facility Permit
May 26, 2010
TABLE 10
BTI Analytical Laboratory Methdds foi- Acceptance of Contaminated Petroleum Sludge
Each Shipment Manifested as Contaminated Petroleum Sludge Will Have
the Following Analysis Performed and Recorded as Indicated:
Analysis
Description -T
Test Method
References
(I}
Odor
Notably different from GWPW (Light gray — black) { _
Observation
Color
PH (1)
Observation
Total Organic
Halides
PH (4)
Chlorinated solvents
EPA Method 9076, 9077, or
8010
API Gravity
pH
pH meter or paper, EPA Method
9040, 9041
(1)
Bottom Sediment
and Water
Water and Sediment by
Centrifuge
ASTM D -1796 or D -4007
(2)
API Gravity
Flash Point Testing
Hydrometer
ASTM D -287
(2)
Pensky Martin Closed Cup
ASTM D -93
(2)
Notes:
1) U.S Environmental Protection Agency, "Test Methods for Evaluating Solid Wastes: �'hysical/Cheniical
Methods ", SW -846, Third Edition, 1986.
2} ASTM Methods - American Society of Testing Materials Methods.
3) Total organic halides must be less than 1,000 PPM unless rebutted. Oils containing total organic halides
> 1,000 PPM and not rebutted will not be received by BTI facility.
4) pH is only measured when there is a separated water layer.
5) If when rising a halogen test kit (EPA Method 9077), the sample turns clear or light gray, there may be too
much water in the sample for this kit. Then, the Dexsil Hydroclor -Q (or equivalent) kit should be used.
TABLE 1 0 A
Fingerprint' I'esting[Discrepancy Criteria for Contaminated Petroleum Sludge
BTI Will Not Accept Contaminated Petroleum Sludge Outside of
Tliose Acceptability Ranaes as Indicated: i
Analysis Requires
Discrepancy Criteria
Odor
Notably different from GWPW (No solvent odor, characteristic of used oil)
Color
Notably different from GWPW (Light gray — black) { _
Total Organic Halides (2)
Must be less than 1,000 PPM unless rebutted r
PH (1)
± 3 pH units, must be ;> 2.0 & c 12.5
Bottom Sediment and eater
Within pre- approved range (1 - 100 %)
API Gravity
Within pre - approved range (.89 --1.3)
Flash Point Testing
CCP must have a flash point > 100 °F
Notes: I. pH is only measured when there is a separated water layer.
Section X1 I, Tables
Page 5 of 22