HomeMy WebLinkAbout1620 e brundage _envirotech report 6.22.20_79-126Bakersfield Transfer, Inc.
Standardized Hazardous Waste Facility Permit, Series B
Effective Date: April 7, 2008
Page 24
Table 1 - Minimum Screening Requirements
.:;u. 's: Montem
g.
�.I-Y,"N - Ell
Used Oil and Contaminated 13 22 314$6
Petroleum Products
Oily Solids
3,5,6
Oily Water
Used Antifreeze
31516
Details of Requirements:
1 Total Organic Halides: Total Organic Halides shall be less than 1,000 ppm. Oils
containing total organic halides greater than 1,000 ppm and not rebutted
pursuant to Special Condition V.N.2. shall not be received by the Facility. The
method must detect the presence of solvents in water. If when using a halogen
test kit (EPA Method 9077), the sample turns clear or light gray, there may be too
much water in the sample for this kit. In this situation, the Dexsil Hydroclor-Q (or
equivalent) shall be used.
2. Flash Point: Each shipment manifested as Used Oil shall have flash point
greater than or equal to 100 OF.
3. pH: If the pH is less than 2 or greater than 12.5, then the water is considered
corrosive. pH shall be measured when there is a separated water layer.
4. PCBs: PCBs shall be tested using EPA method 8082.
5. Specific Gravity: Specific Gravity shall be between 1.0 and 1.3 for Antifreeze.
6. Color: Used antifreeze shall be yellow or green in color. Used oil shall be light
brown to black.