Loading...
HomeMy WebLinkAboutAPSA 6-23-21BAKERSFIELD FIRE DEPT. E k ,: , � Prevention Services i/RE 2101 H Street ARTM r Bakersfield, CA 93301 UNIFIED PROGRAM INSPECTION CHECKLIST � Tel.: (661)326-3979 Fax: (661) 852-2171 Aboveground Petroleum Storage Tank Program FACILITY NAME NisgsAbi rl Si nature ofRecei t� INSPECTION DATE INSPECTION TIME ADDRESS PHONE NO. NO OF EMPLOYEES ?X3 BWL0 CA Ir --f3311 FACILITY CONTACT BUSINESS ID NUMBER / _G-ZJ-� 2 CONSENT TO INSPECT NAME/TITLE/_ SECTION 1: Records Review: California Health & Safety Code: 25270 DESCRIPTION Y N/A COMMENTS Prepare an SPCC plan [CFR 112.3] Review or amend SPCC plan [CFR 112.5 (a)(d)] SPCC plan available on site [CFR 112.3(e)] Conduct inspections and test in accordance with written procedures [CFR 112.7(e)] Maintain records of inspections, tests and/or procedures [CFR 112.7(e)] Records of inspections or tests signed by inspector [CFR 112.7(e)] SECTION 2: SPCC Plan Elements: California Health & Safety Code: 25270.4.5. 25270.12 DESCRIPTION Y ' N N/A COMMENTS Self -certification for Tier I or II facility [I 12.6(a)(1),(b)(1)] Professional engineer certification [CFR 112.3(d) and 112.6(b)(4)] Documentation of 5 year review and evaluation of SPCC plan [CFR 112.5(b)] Amendments required within 6 months of changes/certifications [CFR 112.5(a) and 112.6(a)(2), (b)(4)] Management authorization of resource commitment to implement the SPCC [CFR 112.7 & 112.6(a)] Diagram with location and contents of containers, transfer stations, connecting piping [I 12.7(a)(3)] Type of oil and storage capacity for each container [CFR 112.7(a)(3)] Discharge prevention measures and procedures for routine handling {CFR 112.7(a)(3)] Countermeasures for discovery, response and clean-up [CFR112.7(a)(3)] Required contact list and phone numbers [CFR 112.7(a)(3)] SECTION 3: General SPCC Requirements: California Health & Safety Code: 25270.4.5. 25270.5. 25270.12 DESCRIPTION Y N N/A COMMENTS Provide corrosion protection [CFR 112.8(c)(4)(5), (d)(1)] Af� Containers compatible with materials stored [CFR 112.8(c)(1)] Implement SPCC plan review changes or amendments within 6 months [CFR 112.5(a)(d)] Prepare an oil contingency plan or written control/removal commitments [CFR 112.7(d)] SECTION 4: SPCC Plan Trainina: California Health & Safety Code: 25270.4.5 DESCRIPTION Y N N/A COMMENTS Training program [CFR I I2.7(f)] Train personnel in operation and maintenance of equipment [CFR 112.7(f)] FC-onduct annuals ill prevention briefings [CFR 112.7(f)(3)] 7 1 1 SECTION 5- Facility Insnpctien- California Health & Safety Cede- 25270.4.5 DESCRIPTION Y N/A COMMENTS Meet provisions of conditional exemption [H&S 25270.4.5(b)] Facility security adequate [CFR 112.7( )] Clean-up materials readily available [CFR 112.7(c) Overfill protection procedures or devices in place and operative [CFR 112.8(c)(8)] Portable/mobile containers positioned to prevent discharge [CFR 112.8(c)(11) ,> Loading / unloading rack drains into containment area [CFR I I2.7(h)] Provide appropriate containment /diversionary structures to prevent discharge [CFR 112.8(a), 112.7(c)] Secondary containment adequate to contain capacity of largest container + precipitation [CFR 112.8(c)] Remove accumulation of oil in secondary containment [CFR 112.8(c)(10)] Secondary containment valve(s) closed [CFR 112.8] Implement SPCC plan elements [CFR 112.3] ANY HAZARDOUS WASTE ON SITE? ❑ YES ❑ NO Si nature ofRecei t� Explain: ...r POST INNP1:C:TION INSTRUU 11ON5: • Refer to the back of this inspection report for regulatory citations and corrective actions • Correct the violation(s) noted above by • Within 5 days of correcting all of the violations, sign and return a copy of this page to: Bakersfield Fire Dept., Prevention Services, 2101 H Street, California 93301 White - Business Copy Yellow - Business Copy to be Sent in after return to Compliance Signature (that all violations have been corrected as noted) Date Pink - Prevention Services Copy FD2156b (Rev 9/10)