Loading...
HomeMy WebLinkAboutSB989- 2021 Appendix VII Underground Storage Tank Secondary Containment Testing Report Form CERS = California Environmental Reporting System, ICC = International Code Council, ID = Identification, NA = Not Applicable, UDC = Under-Dispenser Containment, Page 1 of 5 TYPE OF ACTION ☐ Installation ☐ Repair ☐ 6 Month X 36 Month CERS ID 10024420 Test Date 6/28/2021 Facility Name ARCO California Facility Address 3125 California Ave City Bakersfield ZIP Code 93304 Company Performing the Test Advanced Compliance Phone 6617064321 Mailing Address 4007 Brae Burn Dr Bakersfield Ca 93306 Service Technician Performing Test Bradley Hinsley Contractor/Tank Tester License Number 971259 ICC Number 8373948 ICC Expiration Date 8/10/2021 Manufacturer and Test Equipment Training Certifications Expiration Date ICC Service Techican 8/10/2021 INCON STS 10/9/2021 Test Procedures Used Components Tested PEI/RP1200-19 Sect. 4. Tank Annular PEI/RP1200-19 Sect. 5. Line Secondary PEI/RP1200-19 Sect. 6. Containment Sump I hereby certify that the secondary containment was tested in accordance with California Code of Regulations, title 23, division 3, chapter 16, section 2637; that required supporting documentation is attached; and all information contained herein is accurate. I understand that test procedures shall be made available upon request by the governing authority. Service Technician Signature Date 6/28/2021 Total # of Pages 1. FACILITY INFORMATION 2. SERVICE TECHNICIAN INFORMATION 3. TRAINING AND CERTIFICATIONS 4. TEST PROCEDURE INFORMATION 5. CERTIFICATION BY SERVICE TECHNICIAN CONDUCTING TEST 6. TANK SECONDARY CONTAINMENT TEST Underground Storage Tank Secondary Containment Testing Report Form All tests marked “Fail” and any repairs made before or during the tightness test must be described in the COMMENTS section. Page 2 of 5 Test Method Developed by ☐ Manufacturer ☐ Industry Standard X Professional Engineer Test Type ☐ Pressure X Vacuum ☐ Hydrostatic Test Equipment Used: Annular Test Setup Tank ID 87S 87N 91 Tank Manufacturer Unknown Unknown Unknown Tank Capacity 19,703 10,369 11,849 Test Start Time 08:15 08:43 09:38 Initial Reading -10.00InHg -10.00InHg -10.00InHg Test End Time 09:15 09:43 10:38 Final Reading -10.00InHg -10.00InHg -10.00InHg Change in Reading 0.0InHg 0.0InHg 0.0InHg Pass/Fail Criteria +/- 0.0 InHg +/- 0.0 InHg +/- 0.0 InHg Tightness Test Results X Pass ☐ Fail X Pass ☐ Fail X Pass ☐ Fail ☐ Pass ☐ Fail Test Method Developed by ☐ Manufacturer ☐ Industry Standard X Professional Engineer Test Type X Pressure ☐ Vacuum ☐ Hydrostatic Test Equipment Used: Piping Secondary Test Setup Pipe Run ID 87N Product 87S Product 91 Product 87N-87S Line Pipe Manufacturer Unknown Unknown Unknown Unknown Test Start Time 07:38 08:12 09:06 08:05 Initial Reading 5.0 PSI 5.0 PSI 5.0 PSI 5.0 PSI Test End Time 08:38 09:12 10:06 09:05 Final Reading 5.0 PSI 3.0 PSI 5.0 PSI 5.0 PSI Change in Reading 0.0 PSI 2.0 PSI 0.0 PSI 0.0 PSI Pass/Fail Criteria +/- 0.0 PSI +/- 0.0 PSI +/- 0.0 PSI +/- 0.0 PSI Tightness Test Results X Pass ☐ Fail ☐ Pass X Fail X Pass ☐ Fail X Pass ☐ Fail Pipe Run ID Pipe Manufacturer Test Start Time Initial Reading Test End Time Final Reading Change in Reading Pass/Fail Criteria Tightness Test Results ☐ Pass ☐ Fail ☐ Pass ☐ Fail ☐ Pass ☐ Fail ☐ Pass ☐ Fail Additional copies of this page may be attached. 7. PIPE SECONDARY CONTAINMENT TEST 8. SUMP/UDC TEST Underground Storage Tank Secondary Containment Testing Report Form All tests marked “Fail” and any repairs made before or during the tightness test must be described in the COMMENTS section. Page 3 of 5 Test Method Developed by ☐ Manufacturer ☐ Industry Standard X Professional Engineer Test Type ☐ Pressure ☐ Vacuum X Hydrostatic Test Equipment Used: INCON STS Sump/UDC ID 87S STP 87N STP 91 STP Disp 1/2 Sump Manufacturer Unknown Unknown Unknown Unknown Sump Depth (inches) 61 61 61 49 Sump Bottom to Top of Highest Pipe Penetration (inches) 52 50 52 27 Test Start Time 11:43 10:19 12:49 16:20 Initial Reading 2.4556 7.1697 6.3098 4.2796 Test End Time 11:58 10:34 13:04 16:35 Final Reading 2.4560 7.1706 5.3798 4.2771 Change in Reading 0.0004 0.0009 0.9300 0.0025 Pass/Fail Criteria +/- 0.0020 +/- 0.0020 +/- 0.0020 +/- 0.0020 Tightness Test Results X Pass ☐ Fail X Pass ☐ Fail ☐ Pass X Fail ☐ Pass X Fail Sump/UDC ID Disp 3/4 Disp 5/6 Disp 7/8 Disp 9/10 Sump Manufacturer Unknown Unknown Unknown Unknown Sump Depth (inches) 49 49 49 49 Sump Bottom to Top of Highest Pipe Penetration (inches) 27 27 27 27 Test Start Time 16:20 17:00 15:55 15:22 Initial Reading 6.2913 5.1053 6.5738 5.9309 Test End Time 16:35 17:15 16:10 15:37 Final Reading 6.2908 5.1021 5.6321 5.9311 Change in Reading 0.0005 0.0032 0.9417 0.0002 Pass/Fail Criteria +/- 0.0020 +/- 0.0020 +/- 0.0020 +/- 0.0020 Tightness Test Results X Pass ☐ Fail ☐ Pass X Fail ☐ Pass X Fail X Pass ☐ Fail Additional copies of this page may be attached. Underground Storage Tank Secondary Containment Testing Report Form All tests marked “Fail” and any repairs made before or during the tightness test must be described in the COMMENTS section. Page 4 of 5 Test Method Developed by ☐ Manufacturer ☐ Industry Standard X Professional Engineer Test Type ☐ Pressure ☐ Vacuum X Hydrostatic Test Equipment Used: INCON STS Sump/UDC ID Disp 11/12 Disp 13/14 Disp 15/16 Disp 17/18 Sump Manufacturer Unknown Unknown Unknown Unknown Sump Depth (inches) 49 49 49 49 Sump Bottom to Top of Highest Pipe Penetration (inches) 27 27 27 27 Test Start Time 14:06 15:55 15:22 14:06 Initial Reading 5.5667 4.0995 3.6521 7.2486 Test End Time 14:21 16:10 15:37 14:21 Final Reading 5.5586 4.0013 3.6525 7.2463 Change in Reading 0.0081 0.0982 0.0004 0.0023 Pass/Fail Criteria +/- 0.0020 +/- 0.0020 +/- 0.0020 +/- 0.0020 Tightness Test Results ☐ Pass X Fail ☐ Pass X Fail X Pass ☐ Fail ☐ Pass X Fail Sump/UDC ID Sump Manufacturer Sump Depth (inches) Sump Bottom to Top of Highest Pipe Penetration (inches) Test Start Time Initial Reading Test End Time Final Reading Change in Reading Pass/Fail Criteria Tightness Test Results ☐ Pass ☐ Fail ☐ Pass ☐ Fail ☐ Pass ☐ Fail ☐ Pass ☐ Fail Additional copies of this page may be attached. 8. SUMP/UDC TEST (continued) Underground Storage Tank Secondary Containment Testing Report Form All tests marked “Fail” and any repairs made before or during the tightness test must be described in the COMMENTS section. Page 5 of 5 87S Product Line, 91 STP, Disp 1/2-5/6-7/8-11/12-13/14-17/18 failed, must be repaired and retested. 9. COMMENTS