Loading...
HomeMy WebLinkAboutOVerfill 2021IMPACT VALVE LEAK DETECTOR MONITOR CERTIFICATION OVERFILL OPERABILITY SPILL BUCKET TEST 11000 N. MoPac Expressway, Suite 500 Austin, Texas 78759 Phone: (512) 451-6334 Fax: (512) 459-1459 Date Printed and Mailed: 9/20/2021 BAKERSFIELD FIRE DEPARTMENT OFFICE OF ENVIRONMENTAL SERVICES INSPECTOR KRIS KARNS 1501 TRUXTUN AVE. BAKERSFIELD, CA 93301 Test Date: 9/8/2021 Order Number: 3452699 Dear Regulator, Enclosed are the results of recent testing performed at the following facility: 7-ELEVEN #32241, MKT 2368 4101 CALLOWAY DRIVE BAKERSFIELD, CA 93312 In an effort to keep all our record keeping and reporting requirements as current as possible, Tanknology kindly requests you notify Dawn Kohlmeyer in writing at dkohlmeyer@tanknology.com when your CUPA requires all records to be submitted electronically via the CERS database. Your assistance in this endeavor is greatly appreciated. Testing performed: Sincerely, Dawn Kohlmeyer Manager, Field Reporting LDT 5000 Field Test Apparatus Line Leak Detector Test Page 1 of 1 Work Order:3452699 Date:9/8/2021 Site Name / ID:7-ELEVEN #32241, MKT 2368 / 32241 Address:4101 CALLOWAY DRIVE City:BAKERSFIELD State:CA Zip:93312 Tank ID Product Product Line Tested From Existing/New Mechanical/Electronic Manufacturer/Model Serial No. Pump Operating Pressure (psi) Calibrated Leak (ml/min) Calibrated Leak (gph) Holding PSI *N/A for Electronic LD's Resiliency (ml) *N/A for Electronic LD's Metering PSI *N/A for Electronic LD's Opening Time (sec) *N/A for Electronic LD's Test Results T4 RUL RUL 1 2 Existing Mechanical Vaporless LD-2000 10061089 30.00 189.0 3.00 27.00 155.00 18 6 Pass T5 PUL PUL 1 2 Existing Mechanical Vaporless LD-2000 070886 29.00 189.0 3.00 26.00 170.00 18 7 Pass Technician Comments: Technician Name:Luis Navarro Certification #:147337 Technician Signature:Expire Date:11/27/2021 Environmental Compliance for Petroleum Systems © 2021 Tanknology Inc., Austin, TX. All rights reserved. tanknology.com Impact Valve Inspection Impact Valve Operational Inspection Work Order:3452699 Date:9/8/2021 Site Name/ID:7-ELEVEN #32241, MKT 2368 Address:4101 CALLOWAY DRIVE City:BAKERSFIELD State:CA Zip:93312 How Inspected: Line Test NFPA 30A PEI RP1200 Other Dispenser Number Grade Secure Mount? Valve Lock?Pass/ Fail Comments 1/2 87 Pass Fail Not Tested 1/2 91 Pass Fail Not Tested 3/4 87 Pass Fail Not Tested 3/4 91 Pass Fail Not Tested 5/6 87 Pass Fail Not Tested 5/6 91 Pass Fail Not Tested 7/8 87 Pass Fail Not Tested 7/8 91 Pass Fail Not Tested Technician Comments: Technician Name:Luis Navarro Signature: Environmental Compliance for Petroleum Systems ©2021 Tanknology Inc., Austin, TX. All rights reserved. tanknology.com Tanknology, Inc.800-964-1250 11000 N Mopac Expy #500 Austin, Tx 78759 Luis Navarro 10024393 09/08/2021 7-ELEVEN #32241, MKT 2368 4101 CALLOWAY DRIVE BAKERSFIELD 93312 Class A General Engineering 743160 8171123 12/31/2022 05/28/2022 07/05/2022 07/13/2022 09/08/2021 6 Veeder Root:VR TLS-3XX OPW:EVR Phase 1 VMI:TLDT-5000 Tester Veeder Root TLS-350 329.02 L1 DISP 1-2 PAN L2 L3 DISP 5-6 PAN L4 L5 L6 L7 87 STP SUMP L8 L9 91 FILL SUMP L10 L11 S9 87 FILL VRL USC VAC S10 87 PRODUCT LINE VAC S11 87 STP SUMP-FILL CNCT S12 91 FILL-VENT CONT SUMP S13 91 PRODUCT LINE VAC S14 91 STP SUMP- FILL CNCT 794380-208 DISP 3-4 PAN DISP PAN 7-8 87 ANNULAR 87 FILL SUMP 91-ANNULAR 91 STP SUMP VAPOR PIPING PAN 794380-208 794380-208 794380-208 794380-303 794380-208 794380-208 794380-303 794380-208 794380-208 794380-208 857280-100 857280-100 857280-100 857280-100 857280-100 857280-100 T4 RUL T4 RUL T5 PUL Vaporless LD-2000 T5 PULVaporless LD-2000 T4 RUL T4 RUL T5 PUL T5 PUL 846390-107 846390-107 09/08/2021 10024393 09/08/2021 7-ELEVEN #32241, MKT 2368 4101 CALLOWAY DRIVE BAKERSFIELD 93312 Tanknology, Inc.800-964-1250 11000 N Mopac Expy #500 Austin, TX 78759 Luis Navarro 743160 8171123 12/31/2022 07/05/2022 PEI RP1200 / Hydrostatic OPW Spill Buckets 09/08/2021 2 OPW:EVR Phase 1 T4 : RUL T5: PUL OPW OPW SWRCB, January 2006 Spill Bucket Testing Report Form This form is intended for use by contractors performing annual testing of UST spill containment structures. The completed form and printouts from tests (if applicable), should be provided to the facility owner/operator for submittal to the local regulatory agency. 1. FACILITY INFORMATION Facility Name: 7-ELEVEN #32241, MKT 2368 Date of Testing: 9/8/2021 Facility Address: 4101 CALLOWAY DRIVE , BAKERSFIELD, CA 93312 Facility Contact: Iman 5/18/16 Phone: 661-379-5911 Date Local Agency Was Notified of Testing: 8/10/2021 Name of Local Agency Inspector (if present during testing): Kris Karns, Fire Department 2. TESTING CONTRACTOR INFORMATION Company Name: TANKNOLOGY INC. Technician Conducting Test: Luis Navarro Credentials1: CSLB Contractor ICC Service Tech. SWRCB Tank Tester Other (Specify) License Number(s): 743160 / 8171123 3. SPILL BUCKET TESTING INFORMATION Test Method Used By: Hydrostatic Vacuum Other Test Equipment Used: LAKE TEST Equipment Resolution: 0.0625 in. Identify Spill Bucket (By Tank Number, Stored Product, etc.) Bucket Installation Type: Bucket Diameter: Bucket Depth: Wait time between applying vacuum/water and start of test Test Start Time (TI): Initial Reading (RI): Test End Time(TF): Final Reading (RF): Test Duration(TF–TI): Change in Reading (RF–RI) : Pass/Fail Threshold or Criteria: Test Result: Spill Box # Tank T4 RUL RUL - Fill 1 - Direct - Below Grade in containment sump Direct Bury Contained in Sump 11.00 13.00 15 min 09:00:00 12.00 in. H20 10:00:00 12.00 in. H20 1 hr 0.00 in. H20 +/- 0.00 Pass Spill Box # Tank T5 PUL PUL - Fill 1 - Direct - Below Grade in containment sump Direct Bury Contained in Sump 11.00 13.00 15 min 09:00:00 12.00 in. H20 10:00:00 12.00 in. H20 1 hr 0.00 in. H20 +/- 0.00 Pass Spill Box # Direct Bury Contained in Sump min +/- Spill Box # Direct Bury Contained in Sump min +/- Comments - (include information on repairs made prior to testing, and recommended follow-up for failed tests) CERTIFICATION OF TECHNICIAN RESPONSIBLE FOR CONDUCTING THIS TESTING I hereby certify that all the information contained in this report is true, accurate, and in full compliance with legal requirements. Technician's Signature:Date:9/8/2021 1State laws and regulations do not currently require testing to be performed by a qualified contractor. However, local requirements may be more stringent. WO: 3452699 Appendix IX Underground Storage Tank Overfill Prevention Equipment Inspection Report Form TYPE OF ACTION Installation Test Repair Test 36 Month Test 1. FACILITY INFORMATION CERS ID 10024393 Inspection Date 9/8/2021 Facility Name 7-ELEVEN #32241, MKT 2368 Facility Address 4101 CALLOWAY DRIVE City BAKERSFIELD Zip Code 93312 2. SERVICE TECHNICIAN INFORMATION Company Performing the Inspection Tanknology, Inc. Phone (800) 800-4633 Mailing Address 11000 N. MoPac Suite 500, Austin, Tx. 78759 Service Technician Performing Inspection Luis Navarro Contractor/Tank Tester License Number Class A General Engineering 743160 ICC Number 8171123 Expiration Date 12/31/2022 3. TRAINING AND CERTIFICATIONS Manufacturer and Test Equipment Training Certifications Expiration Date OPW-EVR Phase 1 101183 07/05/2022 - - 4. INSPECTION PROCEDURES INFORMATION Inspection Procedure Used Components Inspected OPW Flapper Drop Tube 5. CERTIFICATION BY SERVICE TECHNICIAN CONDUCTING INSPECTION I hereby certify that the OPE was inspected in accordance with California Code of Regulations, title 23, division 3, chapter 16, section 2637.2; that required supporting documentation is attached; and all information contained herein is accurate. I understand that test procedures shall be made available upon request by the governing authority. Service Technician Signature Date 9/8/2021 Total # of Pages 2 CERS = California Environmental Reporting System, ID = Identification, ICC = International Code Council, OPE = Overfill Prevention Equipment Underground Storage Tank Overfill Prevention Equipment Inspection Report 6. OVERFILL PREVENTION EQUIPMENT DETAILS Tank ID (one OPE per column) Are both vent and tank riser piping secondarily contained? OPE Model What is the OPE response when activated? (Check all that apply) Are flow restrictors installed on vent piping that may interfere with the OPE operation? At what level in the tank is the OPE set to activate? (Inches from bottom of tank) What is the percent capacity of the tank at which the OPE activates? Is the OPE in proper operating condition to respond when the stored substance reaches the designated regulatory level? T4 RUL Yes No OPW Shut off Flow Restricts Flow Audible Alarm Visual Alarm Yes* No 82.500 95.00 Yes No T5 PUL Yes No OPW Shut off Flow Restricts Flow Audible Alarm Visual Alarm Yes* No 82.375 95.00 Yes No T4 RUL Yes No Veeder Root Shut off Flow Restricts Flow Audible Alarm Visual Alarm Yes* No 77.000 90.0 Yes No T5 PUL Yes No Veeder Root Shut off Flow Restricts Flow Audible Alarm Visual Alarm Yes* No 76.750 89.9 Yes No 7. SUMMARY OF TESTING RESULTS OPE Inspection Results Pass Fail Pass Fail Pass Fail Pass Fail 8. COMMENTS Describe all results marked "Fail" and each proposed remedy. *Mark here if: Flow restrictors interfere with overfill prevention and equipment repairs required. Additional copies of this page may be attached. Attach tank chart(s), measurements, calculations, and In-Tank Setup report(s) Overfill Prevention Equipment Inspection OPW 61 and 71 Series Overfill Prevention Device Inspection Date:9/8/2021 Customer Name:7-ELEVEN, INC. Location #:7-ELEVEN #32241, MKT 2368 Location Address:4101 CALLOWAY DRIVE ,BAKERSFIELD ,CA , 93312 OPW Model Number:61SO PART 1) Proper height setting calculation Maximum Tank Volume per: Tank Chart A gallons Max shut off requirement for Flapper is 95% B 95% Multiply Maximum tank volume by 95% C gallons Use tank chart to determine height of calculated volume D inches Measure top of fill riser threads, or face seal adapter when used, to tank top E inches Tank diameter From Chart F inches Upper Tube in tank (G) F - D = G G inches Subtract 2 inches from upper tube in tank G - 2"= H H inches Calculated minimum upper tube length (I) H + E = I I inches Actual measured upper tube length (Without fill adapter) (J) J inches PART 2) Device certification criteria evaluation Criteria 1 Does the overfill prevention device meet the 95% requirement? Criteria 1a If the final shutoff volume is installed greater than 95%, is there at least 250 gallons of ullage above the overfill device activation point to ensure that none of the tank top fittings are exposed to product, meeting the criteria established in EPA 280.20iic and per OPW installation guidelines. Criteria 2 Is the Actual measured upper tube length 6.5 inches or more than the fill riser? (J must be 6.5" or more than E) Criteria 3 Does the overfill prevention device function as required? (Inspect the device for damage, contamination, freedom of movement, weakening due to wear and corrosion) PART 3) Device Certification PASS / FAIL Technician certifies that the device is operationally compliant. T4 RUL 14545.000 0.95 13817.750 82.500 62.500 91.625 9.125 7.125 69.625 69.625 Yes NA Yes Yes Pass T5 PUL 9696.000 0.95 9211.200 82.375 60.125 91.625 9.250 7.250 67.375 67.375 Yes NA Yes Yes Pass 0.95 0.95 Comments: Signature of Technician: Date: 9/8/2021 Luis Navarro WO: SC1- 3452699 Site Diagram (This site diagram is for reference only and is not drawn to scale) Work Order:3452699 Site ID / Name:32241 / 7-ELEVEN #32241, MKT 2368 Address:4101 CALLOWAY DRIVE City:BAKERSFIELD State:CA Zip:93312 Test Duration Test Pressure P/F Threshold Tank Annular - Vacuum 1 hr, 20k or less tank 10" hg 0 loss, int dry before and after test Tank Annular - Vacuum 2 hr, >20k tank 10" hg 0 loss, int dry before and after test Line Annular - Pressure 1 hr 5 psi 0 loss STP Sump - Hydro 1 hr 4" above highest penetration or sidewall seam less than 1/8" over hour, settle time of 15 minutes minimum prior to starting the test UDC Sump - Hydro 1 hr 4" above highest penetration or sidewall seam less than 1/8" over hour, settle time of 15 minutes minimum prior to starting the test Spill Bucket - SW Vac 1 min 30" wc no greater than 4" wc vaccum decay - bucket must be dry Spill Bucket - SW Hydro 1 hr within 1.5" of top of the bucket less than 1/8" over hour, settle time of 5 minutest minimum prior to starting the test Spill Bucket - DW Vac 1 min 15" wc no greater than 3" wc vaccum decay - int must be dry W.O.# SC1-3452699 Responses Received: I10200 SEP 8, 2021 10:45 AM 185368 235421 7-11 3 4101 CALLOWAY DR BAKERSFIELD,CA 93312 SYSTEM CONFIGURATION SLOT BOARD TYPE POWER ON RESET CURRENT 1 4 PROBE / G.T. 163706 163559 2 4 PROBE / G.T. 163146 163045 3 INTERSTITIAL BD 201637 201575 4 INTERSTITIAL BD 201761 201525 5 8SMARTSENSOR BD 39291 39344 6 7SMARTSENSOR BD 505642 505782 7 UNUSED 4837853 4805647 8 UNUSED 4828295 4801690 9 RELAY BOARD 14946 14984 10 RELAY BOARD 15083 15122 11 STP SENSE BOARD 33127 33120 12 UNUSED 4835940 4806669 13 UNUSED 4834938 4811518 14 UNUSED 4835416 4808613 15 UNUSED 4835780 4813051 16 UNUSED 4836804 4808064 COMM 1 ELEC DISP INT. 101037 101032 COMM 2 ELEC DISP INT. 101155 101128 COMM 3 SERIAL SAT BD 486464 486424 COMM 4 UNUSED 4839945 4809505 COMM 5 RS485 SERIAL BD 68801 68839 COMM 6 MT COMM BOARD 409443 409295 I90200 SEP 8, 2021 10:45 AM SOFTWARE REVISION LEVEL VERSION 329.02 SOFTWARE+ACM- 346329-100-C CREATED - 09.07.01.16.29 S-MODULE+ACM- 330160-104-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS BIR ISD I11100 SEP 8, 2021 10:45 AM 185368 235421 7-11 3 4101 CALLOWAY DR BAKERSFIELD,CA 93312 PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME T 5 TANK PUL HIGH WATER ALARM CLEAR 9-08-21 10:28AM T 4 TANK RUL HIGH WATER ALARM CLEAR 9-08-21 10:25AM T 5 TANK PUL MAX PRODUCT ALARM CLEAR 9-08-21 10:24AM T 5 TANK PUL PROBE OUT CLEAR 9-08-21 10:24AM T 5 TANK PUL OVERFILL ALARM CLEAR 9-08-21 10:23AM T 5 TANK PUL PROBE OUT ALARM 9-08-21 10:23AM T 5 TANK PUL MAX PRODUCT ALARM ALARM 9-08-21 10:23AM T 5 TANK PUL OVERFILL ALARM ALARM 9-08-21 10:23AM T 5 TANK PUL SUDDEN LOSS ALARM CLEAR 9-08-21 10:22AM T 5 TANK PUL LOW PRODUCT ALARM CLEAR 9-08-21 10:22AM T 4 TANK RUL PROBE OUT CLEAR 9-08-21 10:22AM T 4 TANK RUL MAX PRODUCT ALARM CLEAR 9-08-21 10:22AM T 4 TANK RUL OVERFILL ALARM CLEAR 9-08-21 10:21AM T 4 TANK RUL PROBE OUT ALARM 9-08-21 10:21AM T 4 TANK RUL MAX PRODUCT ALARM ALARM 9-08-21 10:21AM T 4 TANK RUL OVERFILL ALARM ALARM 9-08-21 10:20AM T 4 TANK RUL SUDDEN LOSS ALARM CLEAR 9-08-21 10:20AM T 5 TANK PUL HIGH WATER ALARM ALARM 9-08-21 10:20AM T 4 TANK RUL LOW PRODUCT ALARM CLEAR 9-08-21 10:20AM T 5 TANK PUL PROBE OUT CLEAR 9-08-21 10:19AM T 4 TANK RUL HIGH WATER ALARM ALARM 9-08-21 10:18AM T 5 TANK PUL LOW PRODUCT ALARM ALARM 9-08-21 10:17AM L 8 ANNULAR 91-ANNULAR SENSOR OUT ALARM CLEAR 9-08-21 10:16AM L 7 STP SUMP 87 STP SUMP SENSOR OUT ALARM CLEAR 9-08-21 10:16AM L 4 DISP PAN DISP PAN 7-8 SENSOR OUT ALARM CLEAR 9-08-21 10:16AM L 6 PIPE 87 FILL SUMP SENSOR OUT ALARM CLEAR 9-08-21 10:16AM L 3 DISP PAN DISP 5-6 PAN SENSOR OUT ALARM CLEAR 9-08-21 10:16AM L 5 ANNULAR 87 ANNULAR SENSOR OUT ALARM CLEAR 9-08-21 10:16AM L 2 DISP PAN DISP 3-4 PAN SENSOR OUT ALARM CLEAR 9-08-21 10:16AM L 1 DISP PAN DISP 1-2 PAN SENSOR OUT ALARM CLEAR 9-08-21 10:16AM L11 PIPE VAPOR PIPING PAN SENSOR OUT ALARM CLEAR 9-08-21 10:16AM L10 STP SUMP 91 STP SUMP SENSOR OUT ALARM CLEAR 9-08-21 10:16AM L 9 PIPE 91 FILL SUMP SENSOR OUT ALARM CLEAR 9-08-21 10:16AM L 4 DISP PAN DISP PAN 7-8 SENSOR OUT ALARM ALARM 9-08-21 10:16AM L11 PIPE VAPOR PIPING PAN SENSOR OUT ALARM ALARM 9-08-21 10:16AM L 3 DISP PAN DISP 5-6 PAN SENSOR OUT ALARM ALARM 9-08-21 10:16AM L 8 ANNULAR 91-ANNULAR SENSOR OUT ALARM ALARM 9-08-21 10:16AM L10 STP SUMP 91 STP SUMP SENSOR OUT ALARM ALARM 9-08-21 10:16AM L 2 DISP PAN DISP 3-4 PAN SENSOR OUT ALARM ALARM 9-08-21 10:16AM L 7 STP SUMP 87 STP SUMP SENSOR OUT ALARM ALARM 9-08-21 10:16AM L 9 PIPE 91 FILL SUMP SENSOR OUT ALARM ALARM 9-08-21 10:16AM L 1 DISP PAN DISP 1-2 PAN SENSOR OUT ALARM ALARM 9-08-21 10:16AM L 6 PIPE 87 FILL SUMP SENSOR OUT ALARM ALARM 9-08-21 10:16AM L 5 ANNULAR 87 ANNULAR SENSOR OUT ALARM ALARM 9-08-21 10:16AM T 5 TANK PUL PROBE OUT ALARM 9-08-21 10:15AM T 5 TANK PUL SUDDEN LOSS ALARM ALARM 9-08-21 10:15AM T 4 TANK RUL LOW PRODUCT ALARM ALARM 9-08-21 10:15AM T 4 TANK RUL PROBE OUT CLEAR 9-08-21 10:14AM T 4 TANK RUL PROBE OUT ALARM 9-08-21 10:13AM s12 OTHER 91FILL-VENT-CONTSUMP HIGH LIQUID ALARM CLEAR 9-08-21 10:12AM I11200 SEP 8, 2021 10:45 AM 185368 235421 7-11 3 4101 CALLOWAY DR BAKERSFIELD,CA 93312 NON-PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME T 5 TANK PUL HIGH WATER WARNING CLEAR 9-08-21 10:28AM T 4 TANK RUL HIGH WATER WARNING CLEAR 9-08-21 10:25AM T 5 TANK PUL HIGH PRODUCT ALARM CLEAR 9-08-21 10:24AM T 5 TANK PUL HIGH PRODUCT ALARM ALARM 9-08-21 10:23AM T 5 TANK PUL INVALID FUEL LEVEL CLEAR 9-08-21 10:22AM T 5 TANK PUL DELIVERY NEEDED CLEAR 9-08-21 10:22AM T 4 TANK RUL HIGH PRODUCT ALARM CLEAR 9-08-21 10:22AM T 4 TANK RUL HIGH PRODUCT ALARM ALARM 9-08-21 10:20AM T 5 TANK PUL HIGH WATER WARNING ALARM 9-08-21 10:20AM T 4 TANK RUL DELIVERY NEEDED CLEAR 9-08-21 10:20AM T 4 TANK RUL INVALID FUEL LEVEL CLEAR 9-08-21 10:20AM T 4 TANK RUL HIGH WATER WARNING ALARM 9-08-21 10:18AM T 5 TANK PUL DELIVERY NEEDED ALARM 9-08-21 10:17AM T 5 TANK PUL INVALID FUEL LEVEL ALARM 9-08-21 10:17AM T 4 TANK RUL DELIVERY NEEDED ALARM 9-08-21 10:15AM T 4 TANK RUL INVALID FUEL LEVEL ALARM 9-08-21 10:15AM SYSTEM PRINTER ERROR CLEAR 9-07-21 4:13PM SYSTEM PRINTER ERROR ALARM 9-07-21 4:12PM SYSTEM PRINTER ERROR CLEAR 9-07-21 4:12PM SYSTEM PRINTER ERROR ALARM 9-07-21 4:12PM SYSTEM PRINTER ERROR CLEAR 9-07-21 4:12PM SYSTEM PAPER OUT CLEAR 9-07-21 4:12PM SYSTEM PRINTER ERROR ALARM 9-07-21 4:11PM SYSTEM PAPER OUT ALARM 9-07-21 4:11PM SYSTEM PRINTER ERROR CLEAR 9-07-21 4:11PM SYSTEM PAPER OUT CLEAR 9-07-21 4:11PM SYSTEM PAPER OUT ALARM 9-07-21 4:10PM SYSTEM PRINTER ERROR ALARM 9-07-21 4:10PM SYSTEM PRINTER ERROR CLEAR 9-07-21 4:09PM SYSTEM PRINTER ERROR ALARM 9-07-21 4:09PM SYSTEM PRINTER ERROR CLEAR 9-07-21 4:08PM SYSTEM PAPER OUT CLEAR 9-07-21 4:08PM SYSTEM PRINTER ERROR ALARM 9-07-21 4:08PM SYSTEM PAPER OUT ALARM 9-07-21 4:08PM SYSTEM PRINTER ERROR CLEAR 9-07-21 4:08PM SYSTEM PAPER OUT CLEAR 9-07-21 4:08PM SYSTEM PRINTER ERROR ALARM 9-07-21 3:57PM SYSTEM PAPER OUT ALARM 9-07-21 3:57PM h 3 OTHER FP3: BLEND3 DEGRD COLLECT WARN CLEAR 9-01-21 11:39AM h 3 OTHER FP3: BLEND3 DEGRD COLLECT WARN ALARM 9-01-21 9:04AM h 3 OTHER FP3: BLEND3 DEGRD COLLECT WARN CLEAR 8-12-21 3:44PM h 3 OTHER FP3: BLEND3 DEGRD COLLECT WARN ALARM 8-12-21 9:03AM T 4 TANK RUL DELIVERY NEEDED CLEAR 8-09-21 10:08AM T 4 TANK RUL DELIVERY NEEDED ALARM 8-09-21 8:07AM h 3 OTHER FP3: BLEND3 DEGRD COLLECT WARN CLEAR 7-30-21 9:39AM h 3 OTHER FP3: BLEND3 DEGRD COLLECT WARN ALARM 7-30-21 9:03AM T 4 TANK RUL DELIVERY NEEDED CLEAR 7-22-21 4:35PM T 4 TANK RUL DELIVERY NEEDED ALARM 7-22-21 1:05PM T 4 TANK RUL DELIVERY NEEDED CLEAR 7-16-21 3:48AM T 4 TANK RUL DELIVERY NEEDED ALARM 7-15-21 3:36PM I20600 SEP 8, 2021 10:45 AM 185368 235421 7-11 3 4101 CALLOWAY DR BAKERSFIELD,CA 93312 TANK ALARM HISTORY TANK 4 RUL HIGH WATER ALARM SEP 8, 2021 10:18 AM OVERFILL ALARM SEP 8, 2021 10:20 AM JUN 30, 2021 2:16 AM JUN 26, 2021 5:10 AM LOW PRODUCT ALARM SEP 8, 2021 10:15 AM SUDDEN LOSS ALARM SEP 8, 2021 10:12 AM HIGH PRODUCT ALARM SEP 8, 2021 10:20 AM INVALID FUEL LEVEL SEP 8, 2021 10:15 AM PROBE OUT SEP 8, 2021 10:21 AM SEP 8, 2021 10:13 AM HIGH WATER WARNING SEP 8, 2021 10:18 AM DELIVERY NEEDED SEP 8, 2021 10:15 AM AUG 9, 2021 8:07 AM JUL 22, 2021 1:05 PM MAX PRODUCT ALARM SEP 8, 2021 10:21 AM TANK 5 PUL HIGH WATER ALARM SEP 8, 2021 10:20 AM OVERFILL ALARM SEP 8, 2021 10:23 AM AUG 19, 2021 4:03 PM JUN 4, 2021 8:45 AM LOW PRODUCT ALARM SEP 8, 2021 10:17 AM SUDDEN LOSS ALARM SEP 8, 2021 10:15 AM HIGH PRODUCT ALARM SEP 8, 2021 10:23 AM INVALID FUEL LEVEL SEP 8, 2021 10:17 AM PROBE OUT SEP 8, 2021 10:23 AM SEP 8, 2021 10:15 AM HIGH WATER WARNING SEP 8, 2021 10:20 AM DELIVERY NEEDED SEP 8, 2021 10:17 AM MAR 25, 2021 11:10 AM MAX PRODUCT ALARM SEP 8, 2021 10:23 AM I38200 SEP 8, 2021 10:46 AM I30200 SEP 8, 2021 10:46 AM 185368 235421 7-11 3 4101 CALLOWAY DR BAKERSFIELD,CA 93312 LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 DISP 1-2 PAN SEP 8, 2021 10:16 AM SENSOR OUT ALARM SEP 8, 2021 9:29 AM FUEL ALARM OCT 21, 2020 6:11 PM FUEL ALARM 2 DISP 3-4 PAN SEP 8, 2021 10:16 AM SENSOR OUT ALARM SEP 8, 2021 9:34 AM FUEL ALARM OCT 21, 2020 6:12 PM FUEL ALARM 3 DISP 5-6 PAN SEP 8, 2021 10:16 AM SENSOR OUT ALARM SEP 8, 2021 9:40 AM FUEL ALARM OCT 21, 2020 6:13 PM FUEL ALARM 4 DISP PAN 7-8 SEP 8, 2021 10:16 AM SENSOR OUT ALARM SEP 8, 2021 9:50 AM FUEL ALARM OCT 21, 2020 6:13 PM FUEL ALARM 5 87 ANNULAR SEP 8, 2021 10:16 AM SENSOR OUT ALARM SEP 8, 2021 9:24 AM LOW LIQUID ALARM SEP 8, 2021 9:24 AM HIGH LIQUID ALARM 6 87 FILL SUMP SEP 8, 2021 10:16 AM SENSOR OUT ALARM SEP 8, 2021 9:18 AM FUEL ALARM OCT 21, 2020 6:42 PM FUEL ALARM 7 87 STP SUMP SEP 8, 2021 10:16 AM SENSOR OUT ALARM SEP 8, 2021 9:12 AM FUEL ALARM OCT 21, 2020 6:15 PM FUEL ALARM 8 91-ANNULAR SEP 8, 2021 10:16 AM SENSOR OUT ALARM SEP 8, 2021 9:25 AM LOW LIQUID ALARM SEP 8, 2021 9:24 AM HIGH LIQUID ALARM 9 91 FILL SUMP SEP 8, 2021 10:16 AM SENSOR OUT ALARM SEP 8, 2021 9:18 AM FUEL ALARM OCT 21, 2020 6:43 PM FUEL ALARM 10 91 STP SUMP SEP 8, 2021 10:16 AM SENSOR OUT ALARM SEP 8, 2021 9:13 AM FUEL ALARM OCT 21, 2020 6:16 PM FUEL ALARM 11 VAPOR PIPING PAN SEP 8, 2021 10:16 AM SENSOR OUT ALARM SEP 8, 2021 9:57 AM FUEL ALARM OCT 21, 2020 2:52 PM SETUP DATA WARNING I31600 SEP 8, 2021 10:46 AM 185368 235421 7-11 3 4101 CALLOWAY DR BAKERSFIELD,CA 93312 SMART SENSOR ALARM HISTORY REPORT SENSOR LOCATION 1 1-2 FLOW METER 2 3-4 FLOW METER 3 5-6 FLOW METER 4 7-8 FLOW METER 8 PRESSURE SENSOR 9 87 FILL VRL UDC VAC SEP 8, 2021 10:08 AM HIGH LIQUID ALARM SEP 8, 2021 10:08 AM NO VACUUM ALARM MAY 7, 2021 11:22 AM VACUUM WARNING 10 87 PRODUCT LINE VAC SEP 8, 2021 10:08 AM HIGH LIQUID ALARM SEP 8, 2021 10:08 AM NO VACUUM ALARM NOV 3, 2020 10:21 AM NO VACUUM ALARM 11 87 STPSUMP-FILLCNCT SEP 8, 2021 10:08 AM HIGH LIQUID ALARM SEP 8, 2021 10:08 AM NO VACUUM ALARM NOV 3, 2020 10:21 AM NO VACUUM ALARM 12 91FILL-VENT-CONTSUMP SEP 8, 2021 10:11 AM HIGH LIQUID ALARM SEP 8, 2021 10:11 AM NO VACUUM ALARM OCT 21, 2020 2:56 PM SETUP DATA WARNING 13 91 PRODUCT LINE VAC SEP 8, 2021 10:11 AM HIGH LIQUID ALARM SEP 8, 2021 10:11 AM NO VACUUM ALARM JUL 13, 2021 3:57 PM VACUUM WARNING 14 91 STPSUMP-FILLCNCT SEP 8, 2021 10:11 AM HIGH LIQUID ALARM SEP 8, 2021 10:11 AM NO VACUUM ALARM OCT 21, 2020 2:56 PM SETUP DATA WARNING 16 ATM P SENSOR 5-6 I40200 SEP 8, 2021 10:46 AM I40300 SEP 8, 2021 10:46 AM I34200 SEP 8, 2021 10:46 AM I34700 SEP 8, 2021 10:46 AM IV0100 SEP 8, 2021 10:46 AM 185368 235421 7-11 3 4101 CALLOWAY DR BAKERSFIELD,CA 93312 ISD ALARM STATUS REPORT EVR TYPE: VACUUM ASSIST ISD TYPE: 01.02 VAPOR PROCESSOR TYPE: NONE OVERALL STATUS :PASS EVR VAPOR COLLECTION :PASS EVR VAPOR CONTAINMENT :PASS ISD MONITOR UP-TIME :100+ACU- STAGE I TRANSFERS: 0 of 0 NOTEST EVR/ISD PASS TIME :100+ACU- WARNING ALARMS DATE TIME DESCRIPTION READING VALUE 21-09-01 09:04:38 A/L RATIO DEGRADATION FP 3 BLEND3 0.80 21-08-12 09:03:00 A/L RATIO DEGRADATION FP 3 BLEND3 0.74 21-07-30 09:03:49 A/L RATIO DEGRADATION FP 3 BLEND3 0.78 21-05-20 09:01:12 A/L RATIO DEGRADATION FP 1 BLEND3 0.75 21-05-19 09:01:09 A/L RATIO DEGRADATION FP 1 BLEND3 0.75 21-05-18 09:01:17 A/L RATIO DEGRADATION FP 1 BLEND3 0.77 21-05-17 09:01:21 A/L RATIO DEGRADATION FP 1 BLEND3 0.79 21-05-04 09:00:23 21-05-03 09:00:22 21-03-15 09:01:45 VAPOR CONTAINMENT LEAKAGE CFH+AEA-2 INCHES WC 198.78 FAILURE ALARMS DATE TIME DESCRIPTION READING VALUE 20-11-27 09:04:49 A/L RATIO GROSS BLOCKAGE FP 5 BLEND3 2.11 18-12-12 09:02:45 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95+ACU- 3.77 18-09-25 09:02:34 A/L RATIO DEGRADATION FP 7 BLEND3 0.77 18-09-14 09:04:48 A/L RATIO GROSS BLOCKAGE FP 6 BLEND3 BLKD 16-12-17 09:01:15 A/L RATIO GROSS BLOCKAGE FP 6 BLEND3 BLKD 16-12-17 09:01:15 A/L RATIO GROSS BLOCKAGE FP 5 BLEND3 BLKD 16-12-11 09:01:17 A/L RATIO GROSS BLOCKAGE FP 2 BLEND3 BLKD 16-11-20 09:01:50 A/L RATIO GROSS BLOCKAGE FP 8 BLEND3 BLKD 16-09-14 09:03:25 A/L RATIO DEGRADATION FP 5 BLEND3 0.78 15-03-16 09:01:11 A/L RATIO GROSS BLOCKAGE FP 4 BLEND3 BLKD SHUTDOWN +ACY- MISCELLANEOUS EVENTS DATE TIME DESCRIPTION ACTION/NAME 21-09-08 10:17:05 READINESS ISD:PP EVR:NN EVR READINESS PENDING 21-09-08 10:17:05 ISD STARTUP 21-09-08 10:16:55 ISD SHUTDOWN 21-09-01 11:39:16 COLLECTION TEST HH03 GRADE TEST MANUALLY CLEARED 21-08-12 15:44:28 COLLECTION TEST HH03 GRADE TEST MANUALLY CLEARED 21-07-30 09:39:13 COLLECTION TEST HH03 GRADE TEST MANUALLY CLEARED 21-05-20 09:15:56 COLLECTION TEST HH01 GRADE TEST MANUALLY CLEARED 21-03-15 10:18:52 CONTAINMENT VAPOR LEAKAGE TEST MANUALLY CLEARED 21-03-14 03:00:00 TIME CHANGE DETECTED AT: 21-03-14 02:00:13 21-03-04 09:22:56 CONTAINMENT VAPOR LEAKAGE TEST MANUALLY CLEARED W.O.# SC1-3452699 Responses Received: 200185368 235421 7-11 3 4101 CALLOWAY DR BAKERSFIELD,CA 93312 SEP 8, 2021 10:47 AM TANK PRODUCT GALLONS INCHES WATER DEG F ULLAGE 4 RUL 9159 54.02 0.0 86.6 5242 5 PUL 7695 65.61 0.0 87.7 2000 I90500SEP 8, 2021 10:47 AMSOFTWARE REVISION LEVEL VERSION 329.02SOFTWARE+ACM- 346329-100-C CREATED - 09.07.01.16.29 S-MODULE+ACM- 330160-104-aSYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS BIR ISD I50500SEP 8, 2021 10:47 AM SYSTEM TYPE AND LANGUAGE FLAG SYSTEM UNITS U.S. SYSTEM LANGUAGE ENGLISHSYSTEM DATE/TIME FORMATMON DD YYYY HH:MM:SS xM I50201 SEP 8, 2021 10:47 AM SHIFT TIME 1 : 7:00 AM I50202SEP 8, 2021 10:47 AM SHIFT TIME 2 : DISABLED I50203SEP 8, 2021 10:47 AM SHIFT TIME 3 : DISABLED I50204SEP 8, 2021 10:47 AM SHIFT TIME 4 : DISABLED I54600SEP 8, 2021 10:47 AM TANK PER TST NEEDED WRN: DISABLED I54900SEP 8, 2021 10:47 AM TANK ANN TST NEEDED WRN: DISABLED I55300SEP 8, 2021 10:47 AM LINE RE-ENABLE METHODPASS LINE TEST I55600SEP 8, 2021 10:47 AM LINE PER TST NEEDED WRN: DISABLED I55900SEP 8, 2021 10:47 AM LINE ANN TST NEEDED WRN: DISABLED I50D00SEP 8, 2021 10:47 AM PRINT TC VOLUMESENABLED I50E00SEP 8, 2021 10:47 AM TEMP COMPENSATIONVALUE (DEG F ): 60.0 I60B00SEP 8, 2021 10:47 AM STICK HEIGHT OFFSET ENABLE STATUSDISABLED I51400SEP 8, 2021 10:47 AM H-PROTOCOL DATA FORMATHEIGHT I51A01SEP 8, 2021 10:47 AM DAYLIGHT SAVING TIMEENABLED ON I51B00SEP 8, 2021 10:47 AM DAYLIGHT SAVING TIME START DATE MAR WEEK 2 SUN 2:00 AM END DATE NOV WEEK 1 SUN 2:00 AM I51600 SEP 8, 2021 10:47 AM RE-DIRECT LOCAL PRINTOUTDISABLED I50400 SEP 8, 2021 10:47 AM 232 SECURITY CODE PORT SECURITY CODE STATUS 1 000000 DISABLED 2 000000 DISABLED 3 000000 DISABLED 4 000000 DISABLED 5 000000 DISABLED 6 000000 DISABLED I21900SEP 8, 2021 10:47 AM TANK CHART SECURITYDISABLED I5BD00SEP 8, 2021 10:47 AM CUSTOM ALARM LABELS DISABLED I56000SEP 8, 2021 10:47 AM MASS/DENSITY DISABLED I88101 SEP 8, 2021 10:47 AMPORT SETTINGS: COMM BOARD : 1 (EDIM ) RS-232 SECURITYCODE : DISABLED I88102SEP 8, 2021 10:47 AMPORT SETTINGS: COMM BOARD : 2 (EDIM )RS-232 SECURITYCODE : DISABLED I88103SEP 8, 2021 10:47 AMPORT SETTINGS: COMM BOARD : 3 (S-SAT ) BAUD RATE : 9600 PARITY : NONE STOP BIT : 1 STOP DATA LENGTH: 8 DATARS-232 SECURITYCODE : DISABLED DTR NORMAL STATE: HIGH I88104SEP 8, 2021 10:47 AM I88105SEP 8, 2021 10:47 AMPORT SETTINGS: COMM BOARD : 5 (RS-485) BAUD RATE : 1200 PARITY : ODD STOP BIT : 1 STOP DATA LENGTH: 7 DATARS-232 SECURITYCODE : DISABLED I88106SEP 8, 2021 10:47 AMPORT SETTINGS: COMM BOARD : 6 (MTCOMM) BAUD RATE : 9600 PARITY : ODD STOP BIT : 1 STOP DATA LENGTH: 7 DATARS-232 SECURITYCODE : DISABLED I52000SEP 8, 2021 10:47 AM RECEIVER AUTO DIAL TYPE +ACY- START TIME RCVR LOCATION LABEL DIAL TYPE START TIME 1 ON DATE DEC 4, 2012 DISABLED 2 ON DATE DEC 4, 2012 DISABLED 3 ON DATE DEC 4, 2012 DISABLED 4 ON DATE DEC 4, 2012 DISABLED 5 ON DATE DEC 4, 2012 DISABLED 6 ON DATE DEC 4, 2012 DISABLED 7 ON DATE DEC 4, 2012 DISABLED 8 WEEKLY SAT 5:01 PM I60100SEP 8, 2021 10:47 AM TANK CONFIGURATION DEVICE LABEL CONFIGURED 1 OFF 2 OFF 3 OFF 4 RUL ON 5 PUL ON 6 OFF 7 OFF 8 OFF I60200SEP 8, 2021 10:47 AM TANK PRODUCT LABEL TANK PRODUCT LABEL 1 2 3 4 RUL 5 PUL 6 7 8 I60300SEP 8, 2021 10:47 AM TANK PRODUCT CODE TANK PRODUCT LABEL 1 1 2 2 3 3 4 RUL 4 5 PUL 5 6 6 7 7 8 8 I60900SEP 8, 2021 10:47 AM TANK THERMAL COEFFICIENT TANK PRODUCT LABEL 1 0.000000 2 0.000000 3 0.000000 4 RUL 0.000700 5 PUL 0.000700 6 0.000000 7 0.000000 8 0.000000 I60700SEP 8, 2021 10:47 AM TANK DIAMETER TANK PRODUCT LABEL INCHES 1 0.00 2 0.00 3 0.00 4 RUL 91.63 5 PUL 91.63 6 0.00 7 0.00 8 0.00 I60A00SEP 8, 2021 10:47 AM TANK FULL VOLUME TANK PRODUCT LABEL TANK PROFILE GALLONS 1 1 PT 0 2 1 PT 0 3 1 PT 0 4 RUL 20 PTS 14544 5 PUL 4 PTS 9695 6 1 PT 0 7 1 PT 0 8 1 PT 0 I60400SEP 8, 2021 10:47 AM TANK FULL VOLUME TANK PRODUCT LABEL GALLONS 1 0 2 0 3 0 4 RUL 14544 5 PUL 9695 6 0 7 0 8 0 I60500SEP 8, 2021 10:47 AM TANK 4 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 0 0 0 0 2 0 0 0 0 3 0 0 0 0 4 RUL 14544 11764 7298 2825 5 PUL 9695 7859 4863 1863 6 0 0 0 0 7 0 0 0 0 8 0 0 0 0 I60600SEP 8, 2021 10:47 AM TANK 20 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4 RUL 14544 14282 13816 13221 12530 11764 10937 10066 9162 8235 7298 6360 5433 4527 3654 2825 2054 1359 758 284 5 PUL 9695 0 0 0 0 7859 0 0 0 0 4863 0 0 0 0 1863 0 0 0 0 6 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 7 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 8 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 I61500SEP 8, 2021 10:47 AM TANK PRODUCT LABEL METER DATA 1 NO 2 NO 3 NO 4 RUL YES 5 PUL YES 6 NO 7 NO 8 NO I62F00 SEP 8, 2021 10:47 AM MAG PROBE FLOAT SIZE TANK PRODUCT LABEL FLOAT SIZE: 4 RUL 4.0 INCHES 5 PUL 4.0 INCHES I62700SEP 8, 2021 10:47 AM 4 RUL 1.0 5 PUL 1.0 9999FF1B I62400SEP 8, 2021 10:47 AM 4 RUL 1.5 5 PUL 1.5 I62800SEP 8, 2021 10:47 AM TANK MAXIMUM VOLUME LIMIT TANK PRODUCT LABEL GALLONS 1 0 2 0 3 0 4 RUL 14544 5 PUL 9695 6 0 7 0 8 0 I62300SEP 8, 2021 10:47 AM TANK OVERFILL LEVEL LIMIT TANK PRODUCT LABEL GALLONS 1 0 2 0 3 0 4 RUL 13089 5 PUL 8725 6 0 7 0 8 0 I62200SEP 8, 2021 10:47 AM TANK HIGH PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 0 2 0 3 0 4 RUL 13816 5 PUL 9210 6 0 7 0 8 0 I62900SEP 8, 2021 10:47 AM TANK DELIVERY REQUIRED LIMIT TANK PRODUCT LABEL GALLONS 1 0 2 0 3 0 4 RUL 2181 5 PUL 1454 6 0 7 0 8 0 I62100SEP 8, 2021 10:47 AM TANK LOW PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 0 2 0 3 0 4 RUL 800 5 PUL 800 6 0 7 0 8 0 I62600SEP 8, 2021 10:47 AM TANK LEAK ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 99 2 99 3 99 4 RUL 15 5 PUL 15 6 99 7 99 8 99 I62500SEP 8, 2021 10:47 AM TANK SUDDEN LOSS LIMIT TANK PRODUCT LABEL GALLONS 1 99 2 99 3 99 4 RUL 40 5 PUL 40 6 99 7 99 8 99 I60800SEP 8, 2021 10:47 AM TANK TILT TANK PRODUCT LABEL INCHES 1 0.00 2 0.00 3 0.00 4 RUL 0.00 5 PUL -0.50 6 0.00 7 0.00 8 0.00 I60B00SEP 8, 2021 10:47 AM STICK HEIGHT OFFSET ENABLE STATUSDISABLED I60C00SEP 8, 2021 10:47 AM TANK STICK HEIGHT OFFSETTANK PRODUCT LABEL INCHES 1 0.00 2 0.00 3 0.00 4 RUL 0.00 5 PUL 0.00 6 0.00 7 0.00 8 0.00 I61200SEP 8, 2021 10:47 AM TANK MANIFOLDED PARTNERS TANK PRODUCT LABEL SIPHON MANIFOLDED TANKS LINE MANIFOLDED TANKS 1 NONE NONE 2 NONE NONE 3 NONE NONE 4 RUL NONE NONE 5 PUL NONE NONE 6 NONE NONE 7 NONE NONE 8 NONE NONE I63600SEP 8, 2021 10:47 AM PERIODIC LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 0 2 0 3 0 4 RUL 3636 5 PUL 2423 6 0 7 0 8 0 I62A00SEP 8, 2021 10:47 AM ANNUAL LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 0 2 0 3 0 4 RUL 7417 5 PUL 4944 6 0 7 0 8 0 I62C00SEP 8, 2021 10:47 AM TANK PERIODIC TEST TYPE TANK PRODUCT LABEL PERIODIC TEST TYPE 1 STANDARD 2 STANDARD 3 STANDARD 4 RUL STANDARD 5 PUL STANDARD 6 STANDARD 7 STANDARD 8 STANDARD I62D00SEP 8, 2021 10:47 AM TANK LEAK TEST FAIL ALARMS TANK PRODUCT LABEL 1 GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 2 GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 3 GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 4 RUL GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 5 PUL GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 6 GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 7 GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 8 GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED I63100SEP 8, 2021 10:47 AM TANK LEAK TEST AVERAGING TANK PRODUCT LABEL ANNUAL PERIODIC 1 OFF OFF 2 OFF OFF 3 OFF OFF 4 RUL OFF OFF 5 PUL OFF OFF 6 OFF OFF 7 OFF OFF 8 OFF OFF I63000SEP 8, 2021 10:47 AM IN-TANK LEAK TEST NOTIFY TANK PRODUCT LABEL TANK TEST NOTIFY: 1 OFF 2 OFF 3 OFF 4 RUL OFF 5 PUL OFF 6 OFF 7 OFF 8 OFF I63200SEP 8, 2021 10:47 AM TANK TEST SIPHON BREAK TANK PRODUCT LABEL SIPHON BREAK 1 OFF 2 OFF 3 OFF 4 RUL OFF 5 PUL OFF 6 OFF 7 OFF 8 OFF I61000 SEP 8, 2021 10:47 AM TANK DELIVERY DELAY TANK PRODUCT LABEL 1 1 2 1 3 1 4 RUL 3 5 PUL 3 6 1 7 1 8 1 I63A00 SEP 8, 2021 10:47 AM LOW LEVEL PUMP THRESHOLD FOR SEQUENTIAL LINE MANIFOLD TANK PRODUCT LABEL PUMP THRESHOLD 1 10.00+ACU- 2 10.00+ACU- 3 10.00+ACU- 4 RUL 10.00+ACU- 5 PUL 10.00+ACU- 6 10.00+ACU- 7 10.00+ACU- 8 10.00+ACU- I61100SEP 8, 2021 10:47 AM LEAK TEST METHOD- - - - - - - - - - - -TEST ON DATE : ALL TANKJUL 1, 2009START TIME : DISABLEDTEST RATE :0.20 GAL/HRDURATION : 2 HOURS TST EARLY STOP:DISABLED I61300SEP 8, 2021 10:47 AMCSLD PROBABLITY OF DETECTION I61400SEP 8, 2021 10:47 AMCSLD CLIMATE FACTOR I61600SEP 8, 2021 10:47 AM TANK PRODUCT LABEL CAL UPDATE 1 IMMEDIATE 2 IMMEDIATE 3 IMMEDIATE 4 RUL IMMEDIATE 5 PUL IMMEDIATE 6 IMMEDIATE 7 IMMEDIATE 8 IMMEDIATE I61A00SEP 8, 2021 10:47 AM IN-TANK LEAK TEST EARLY STOP TANK PRODUCT LABEL TST EARLY STOP: 1 DISABLED 2 DISABLED 3 DISABLED 4 RUL DISABLED 5 PUL DISABLED 6 DISABLED 7 DISABLED 8 DISABLED I61B00SEP 8, 2021 10:47 AM IN-TANK LEAK GROSS TEST AUTO-CONFIRM I61C00SEP 8, 2021 10:47 AM CSLD REPORT ONLY I62B00SEP 8, 2021 10:47 AM TANK LAST ANNUAL TEST TANK PRODUCT LABEL DATE 1 ??? 0, 0 2 ??? 0, 0 3 ??? 0, 0 4 RUL ??? 0, 0 5 PUL ??? 0, 0 6 ??? 0, 0 7 ??? 0, 0 8 ??? 0, 0 I63300SEP 8, 2021 10:48 AM LEAK TEST REPORT FORMAT: NORMAL I63400SEP 8, 2021 10:48 AM RECONCILIATION WARNING LIMIT TANK PRODUCT LABEL GALLONS 1 0 2 0 3 0 4 RUL 0 5 PUL 0 6 0 7 0 8 0 I63500SEP 8, 2021 10:48 AM RECONCILIATION ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 1 2 1 3 1 4 RUL 1 5 PUL 1 6 1 7 1 8 1 I63900SEP 8, 2021 10:48 AM ACCU CHART END SHAPE FACTOR TANK PRODUCT LABEL 1 END FACTOR: NONE 2 END FACTOR: NONE 3 END FACTOR: NONE 4 RUL END FACTOR: HEMISPHER 5 PUL END FACTOR: HEMISPHER 6 END FACTOR: NONE 7 END FACTOR: NONE 8 END FACTOR: NONE I78000SEP 8, 2021 10:48 AM I77700SEP 8, 2021 10:48 AM I77800SEP 8, 2021 10:48 AM I78C00SEP 8, 2021 10:48 AM I78300SEP 8, 2021 10:48 AM I78F00SEP 8, 2021 10:48 AM I78700SEP 8, 2021 10:48 AM I70200SEP 8, 2021 10:48 AM LIQUID LABEL DEVICE LABEL 1 DISP 1-2 PAN 2 DISP 3-4 PAN 3 DISP 5-6 PAN 4 DISP PAN 7-8 5 87 ANNULAR 6 87 FILL SUMP 7 87 STP SUMP 8 91-ANNULAR 9 91 FILL SUMP 10 91 STP SUMP 11 VAPOR PIPING PAN 12 13 14 15 16 I70300 SEP 8, 2021 10:48 AM LIQUID TYPE SENSOR LOCATION TYPE 1 DISP 1-2 PAN TRI-STATE (SINGLE FLOAT) 2 DISP 3-4 PAN TRI-STATE (SINGLE FLOAT) 3 DISP 5-6 PAN TRI-STATE (SINGLE FLOAT) 4 DISP PAN 7-8 TRI-STATE (SINGLE FLOAT) 5 87 ANNULAR DUAL POINT HYDROSTATIC 6 87 FILL SUMP TRI-STATE (SINGLE FLOAT) 7 87 STP SUMP TRI-STATE (SINGLE FLOAT) 8 91-ANNULAR DUAL POINT HYDROSTATIC 9 91 FILL SUMP TRI-STATE (SINGLE FLOAT) 10 91 STP SUMP TRI-STATE (SINGLE FLOAT) 11 VAPOR PIPING PAN TRI-STATE (SINGLE FLOAT) 12 TRI-STATE (SINGLE FLOAT) 13 TRI-STATE (SINGLE FLOAT) 14 TRI-STATE (SINGLE FLOAT) 15 TRI-STATE (SINGLE FLOAT) 16 TRI-STATE (SINGLE FLOAT) I70400SEP 8, 2021 10:48 AM LIQUID CATEGORY SENSOR LOCATION CATEGORY 1 DISP 1-2 PAN DISPENSER PAN 2 DISP 3-4 PAN DISPENSER PAN 3 DISP 5-6 PAN DISPENSER PAN 4 DISP PAN 7-8 DISPENSER PAN 5 87 ANNULAR ANNULAR SPACE 6 87 FILL SUMP PIPING SUMP 7 87 STP SUMP STP SUMP 8 91-ANNULAR ANNULAR SPACE 9 91 FILL SUMP PIPING SUMP 10 91 STP SUMP STP SUMP 11 VAPOR PIPING PAN PIPING SUMP 12 OTHER SENSORS 13 OTHER SENSORS 14 OTHER SENSORS 15 OTHER SENSORS 16 OTHER SENSORS I74200SEP 8, 2021 10:48 AM I74300SEP 8, 2021 10:48 AM I74400 SEP 8, 2021 10:48 AM I74700SEP 8, 2021 10:48 AM I74800SEP 8, 2021 10:48 AM I74900SEP 8, 2021 10:48 AM I7BC00SEP 8, 2021 10:48 AM I80200SEP 8, 2021 10:48 AM I80300SEP 8, 2021 10:48 AM I80400SEP 8, 2021 10:48 AM I80700SEP 8, 2021 10:48 AM RELAY LABEL DEVICE LABEL 1 2 3 4 5 87 STP 6 PREMIUM STP 7 8 I80900SEP 8, 2021 10:48 AM RELAY ORIENTATION RELAY DESIGNATION ORIENTATION 1 NORMALLY OPEN 2 NORMALLY OPEN 3 NORMALLY OPEN 4 NORMALLY OPEN 5 87 STP NORMALLY OPEN 6 PREMIUM STP NORMALLY OPEN 7 NORMALLY OPEN 8 NORMALLY OPEN I80B00SEP 8, 2021 10:48 AM RELAY TANK ASSIGNMENT RELAY DESIGNATION TANK 1 NONE 2 NONE 3 NONE 4 NONE 5 87 STP 4 6 PREMIUM STP 5 7 NONE 8 NONE I80A00 SEP 8, 2021 10:48 AM RELAY TYPE RELAY DESIGNATION TYPE 1 STANDARD 2 STANDARD 3 STANDARD 4 STANDARD 5 87 STP PUMP CONTROL OUTPUT 6 PREMIUM STP PUMP CONTROL OUTPUT 7 STANDARD 8 STANDARD I80C00SEP 8, 2021 10:48 AM I80800SEP 8, 2021 10:48 AM RELAY SETUP REPORT R 1: TYPE: STANDARDNORMALLY OPEN TANK +ACM-: NONE - NO ALARM ASSIGNMENTS - R 2: TYPE: STANDARDNORMALLY OPEN TANK +ACM-: NONE - NO ALARM ASSIGNMENTS - R 3: TYPE: STANDARDNORMALLY OPEN TANK +ACM-: NONE - NO ALARM ASSIGNMENTS - R 4: TYPE: STANDARD NORMALLY OPEN TANK +ACM-: NONE - NO ALARM ASSIGNMENTS - R 5:87 STP TYPE: PUMP CONTROL OUTPUTTANK +ACM-: 4 IN-TANK ALARMS T 4:LOW PRODUCT ALARM T 4:GROSS TEST FAIL LIQUID SENSOR ALMS L 1:FUEL ALARM L 2:FUEL ALARM L 3:FUEL ALARM L 4:FUEL ALARM L 6:FUEL ALARM L 7:FUEL ALARM L 1:SENSOR OUT ALARM L 2:SENSOR OUT ALARM L 3:SENSOR OUT ALARM L 4:SENSOR OUT ALARM L 5:SENSOR OUT ALARM L 6:SENSOR OUT ALARM L 7:SENSOR OUT ALARM L 1:SHORT ALARM L 2:SHORT ALARM L 3:SHORT ALARM L 4:SHORT ALARM L 6:SHORT ALARM L 7:SHORT ALARM L 5:HIGH LIQUID ALARM L 6:HIGH LIQUID ALARM L 7:HIGH LIQUID ALARM L 5:LOW LIQUID ALARM COMM SIDE DIM ALM ALL:DISABLED DIM ALARM ALL:COMMUNICATION ALARM ALL:TRANSACTION ALARM SMARTSENSOR ALARMS ALL:SETUP DATA WARNING ALL:COMMUNICATION ALARM ALL:FUEL WARNING ALL:FUEL ALARM ALL:WATER ALARM ALL:LOW LIQUID ALARM ALL:RELAY ACTIVE ALL:INSTALL ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD VP PRES FAIL ISD VP STATUS FAIL MISSING RELAY SETUP MISSING TANK SETUP MISS VAPOR FLOW MTR MISS VAPOR PRES SEN ISD SETUP FAIL ISD SENSOR OUT FAIL ISD HOSE ALARMS ALL:GROSS COLLECT FAIL ALL:DEGRD COLLECT FAIL R 6:PREMIUM STP TYPE: PUMP CONTROL OUTPUTTANK +ACM-: 5 IN-TANK ALARMS T 5:LOW PRODUCT ALARM T 5:GROSS TEST FAIL LIQUID SENSOR ALMS L 1:FUEL ALARM L 2:FUEL ALARM L 3:FUEL ALARM L 4:FUEL ALARM L 9:FUEL ALARM L10:FUEL ALARM L 1:SENSOR OUT ALARM L 2:SENSOR OUT ALARM L 3:SENSOR OUT ALARM L 4:SENSOR OUT ALARM L 8:SENSOR OUT ALARM L 9:SENSOR OUT ALARM L10:SENSOR OUT ALARM L 1:SHORT ALARM L 2:SHORT ALARM L 3:SHORT ALARM L 4:SHORT ALARM L 9:SHORT ALARM L10:SHORT ALARM L 8:HIGH LIQUID ALARM L 8:LOW LIQUID ALARM COMM SIDE DIM ALM ALL:DISABLED DIM ALARM ALL:COMMUNICATION ALARM ALL:TRANSACTION ALARM SMARTSENSOR ALARMS ALL:SETUP DATA WARNING ALL:COMMUNICATION ALARM ALL:FUEL ALARM ALL:LOW LIQUID ALARM ALL:INSTALL ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD VP PRES FAIL ISD VP STATUS FAIL MISSING TANK SETUP MISS VAPOR FLOW MTR MISS VAPOR PRES SEN ISD SETUP FAIL ISD SENSOR OUT FAIL ISD HOSE ALARMS ALL:GROSS COLLECT FAIL ALL:DEGRD COLLECT FAIL R 7: TYPE: STANDARDNORMALLY OPEN TANK +ACM-: NONE - NO ALARM ASSIGNMENTS - R 8: TYPE: STANDARD NORMALLY OPEN TANK +ACM-: NONE - NO ALARM ASSIGNMENTS - I79000SEP 8, 2021 10:48 AM EDIM:1 VR:349781-001-D TD:01.08.15.07.12 EDIM:2 VR:349867-001-C TD:16.05.27.07.44 I79100SEP 8, 2021 10:48 AM I72300 SEP 8, 2021 10:48 AM 185368 235421 7-11 34101 CALLOWAY DR BAKERSFIELD,CA 93312 SMARTSENSOR ASSIGNMENT DEVICE LABEL CATEGORY01 1-2 FLOW METER AIR FLOW METER 02 3-4 FLOW METER AIR FLOW METER03 5-6 FLOW METER AIR FLOW METER04 7-8 FLOW METER AIR FLOW METER05 UNKNOWN 06 UNKNOWN07 UNKNOWN08 PRESSURE SENSOR VAPOR PRESSURE09 87 FILL VRL UDC VAC VAC SENSOR 10 87 PRODUCT LINE VAC VAC SENSOR11 87 STPSUMP-FILLCNCT VAC SENSOR12 91FILL-VENT-CONTSUMP VAC SENSOR13 91 PRODUCT LINE VAC VAC SENSOR 14 91 STPSUMP-FILLCNCT VAC SENSOR15 UNKNOWN16 ATM P SENSOR 5-6 ATM P SENSOR17 UNKNOWN 18 UNKNOWN19 UNKNOWN20 UNKNOWN21 UNKNOWN 22 UNKNOWN23 UNKNOWN24 UNKNOWN25 UNKNOWN 26 UNKNOWN27 UNKNOWN28 UNKNOWN29 UNKNOWN 30 UNKNOWN31 UNKNOWN32 UNKNOWN33 UNKNOWN 34 UNKNOWN35 UNKNOWN36 UNKNOWN37 UNKNOWN 38 UNKNOWN39 UNKNOWN40 UNKNOWN I72A00SEP 8, 2021 10:48 AM VACUUM SENSOR VOLUME DEVICE LABEL VOLUME 9 87 FILL VRL UDC VAC 36.0 GALLONS 10 87 PRODUCT LINE VAC 36.0 GALLONS 11 87 STPSUMP-FILLCNCT 36.0 GALLONS 12 91FILL-VENT-CONTSUMP 36.0 GALLONS 13 91 PRODUCT LINE VAC 36.0 GALLONS 14 91 STPSUMP-FILLCNCT 36.0 GALLONS IV4E00SEP 8, 2021 10:48 AM 185368 235421 7-11 34101 CALLOWAY DR BAKERSFIELD,CA 93312 EVR/ISD SETUPTYPE: VACUUM ASSISTVACUUM ASSIST TYPE: HEALY VAC IV4F00SEP 8, 2021 10:48 AM 185368 235421 7-11 34101 CALLOWAY DR BAKERSFIELD,CA 93312 NOZZLE A/L RANGEA/L RATIO: 0.95 - 1.15 IV4000SEP 8, 2021 10:48 AM 185368 235421 7-11 34101 CALLOWAY DR BAKERSFIELD,CA 93312 VAPOR PROCESSOR TYPENONE IV4700SEP 8, 2021 10:48 AM 185368 235421 7-11 34101 CALLOWAY DR BAKERSFIELD,CA 93312 ASSESSMENT TIMESTART TIME: 9:00 AMTIME DELAY MINUTES: 1 IV5200SEP 8, 2021 10:48 AM 185368 235421 7-11 34101 CALLOWAY DR BAKERSFIELD,CA 93312 ACCEPT HIGH ORVR: NO IV4A00 SEP 8, 2021 10:48 AM 185368 235421 7-11 34101 CALLOWAY DR BAKERSFIELD,CA 93312 ISD HOSE TABLE HOSE FP FP AFM HOSE ID ID LABEL ID LABEL 01 01 01 01 BLEND3 02 02 02 01 BLEND3 03 03 03 02 BLEND3 04 04 04 02 BLEND3 05 05 05 03 BLEND3 06 06 06 03 BLEND3 07 07 07 04 BLEND3 08 08 08 04 BLEND3 IV4B00SEP 8, 2021 10:48 AM 185368 235421 7-11 34101 CALLOWAY DR BAKERSFIELD,CA 93312 PRODUCT/HOSE MAP TABLE FP AFID M1/H1 M2/H2 M3/H3 M4/H401 01 00/01 09/01 02/01 xx/xx02 01 00/02 09/02 02/02 xx/xx03 02 00/03 09/03 02/03 xx/xx 04 02 00/04 09/04 02/04 xx/xx05 03 00/05 09/05 02/05 xx/xx06 03 00/06 09/06 02/06 xx/xx07 04 00/07 09/07 02/07 xx/xx 08 04 00/08 09/08 02/08 xx/xx IV4900SEP 8, 2021 10:48 AM 185368 235421 7-11 3 4101 CALLOWAY DR BAKERSFIELD,CA 93312 LABEL TABLEID LABEL01 UNASSIGNED 02 BLEND3 03 REGULAR 04 MID GRADE 05 PREMIUM 06 GOLD 07 BRONZE 08 SILVER 09 BLEND2 10 BLEND4 IV1000SEP 8, 2021 10:48 AM ISD VERSION: 01.02 8' 15000 DWT6 Double Wall Tank 14545 Gals DIPSTICK GALLONS DIPSTICK GALLONS DIPSTICK GALLONS DIPSTICK GALLONS DIPSTICK GALLONS 1/8 8 6 1/8 427 12 1/8 1,135 18 1/8 2022 24 1/8 3040 1/4 11 6 1/4 440 12 1/4 1,152 18 1/4 2042 24 1/4 3062 3/8 15 6 3/8 452 12 3/8 1,169 18 3/8 2062 24 3/8 3085 1/2 19 6 1/2 465 12 1/2 1,186 18 1/2 2083 24 1/2 3107 5/8 24 6 5/8 477 12 5/8 1,203 18 5/8 2103 24 5/8 3130 3/4 29 6 3/4 490 12 3/4 1,220 18 3/4 2123 24 3/4 3152 7/8 34 6 7/8 503 12 7/8 1,237 18 7/8 2143 24 7/8 3175 1 40 7 516 13 1254 19 2164 25 3197 1 1/8 45 7 1/8 530 13 1/8 1,272 19 1/8 2184 25 1/8 3220 1 1/4 51 7 1/4 543 13 1/4 1,289 19 1/4 2205 25 1/4 3242 1 3/8 58 7 3/8 556 13 3/8 1,307 19 3/8 2225 25 3/8 3265 1 1/2 64 7 1/2 570 13 1/2 1,324 19 1/2 2246 25 1/2 3288 1 5/8 71 7 5/8 583 13 5/8 1,342 19 5/8 2266 25 5/8 3310 1 3/4 78 7 3/4 597 13 3/4 1,360 19 3/4 2287 25 3/4 3333 1 7/8 85 7 7/8 611 13 7/8 1,378 19 7/8 2308 25 7/8 3356 2 93 8 625 14 1396 20 2328 26 3379 2 1/8 100 8 1/8 639 14 1/8 1,414 20 1/8 2349 26 1/8 3402 2 1/4 108 8 1/4 653 14 1/4 1,432 20 1/4 2370 26 1/4 3425 2 3/8 116 8 3/8 667 14 3/8 1,450 20 3/8 2391 26 3/8 3448 2 1/2 124 8 1/2 681 14 1/2 1,468 20 1/2 2412 26 1/2 3471 2 5/8 132 8 5/8 696 14 5/8 1,486 20 5/8 2433 26 5/8 3494 2 3/4 141 8 3/4 710 14 3/4 1,504 20 3/4 2454 26 3/4 3517 2 7/8 150 8 7/8 725 14 7/8 1,523 20 7/8 2475 26 7/8 3540 3 158 9 739 15 1541 21 2496 27 3563 3 1/8 167 9 1/8 754 15 1/8 1,560 21 1/8 2517 27 1/8 3586 3 1/4 177 9 1/4 769 15 1/4 1,578 21 1/4 2539 27 1/4 3609 3 3/8 186 9 3/8 784 15 3/8 1,597 21 3/8 2560 27 3/8 3633 3 1/2 195 9 1/2 799 15 1/2 1,616 21 1/2 2581 27 1/2 36563 1/2 195 9 1/2 799 15 1/2 1,616 21 1/2 2581 27 1/2 3656 3 5/8 205 9 5/8 814 15 5/8 1,634 21 5/8 2603 27 5/8 3679 3 3/4 215 9 3/4 829 15 3/4 1,653 21 3/4 2624 27 3/4 3702 3 7/8 225 9 7/8 845 15 7/8 1,672 21 7/8 2646 27 7/8 3726 4 235 10 860 16 1,691 22 2667 28 3749 4 1/8 245 10 1/8 876 16 1/8 1,710 22 1/8 2689 28 1/8 3773 4 1/4 256 10 1/4 891 16 1/4 1,729 22 1/4 2710 28 1/4 3796 4 3/8 266 10 3/8 907 16 3/8 1,748 22 3/8 2732 28 3/8 3820 4 1/2 277 10 1/2 923 16 1/2 1,767 22 1/2 2754 28 1/2 3843 4 5/8 288 10 5/8 938 16 5/8 1,787 22 5/8 2776 28 5/8 3867 4 3/4 299 10 3/4 954 16 3/4 1,806 22 3/4 2797 28 3/4 3890 4 7/8 310 10 7/8 970 16 7/8 1825 22 7/8 2819 28 7/8 3914 5 321 11 986 17 1845 23 2841 29 3938 5 1/8 332 11 1/8 1003 17 1/8 1864 23 1/8 2863 29 1/8 3961 5 1/4 344 11 1/4 1019 17 1/4 1884 23 1/4 2885 29 1/4 3985 5 3/8 355 11 3/8 1,035 17 3/8 1903 23 3/8 2907 29 3/8 4009 5 1/2 367 11 1/2 1,052 17 1/2 1923 23 1/2 2929 29 1/2 4033 5 5/8 379 11 5/8 1,068 17 5/8 1943 23 5/8 2951 29 5/8 4056 5 3/4 391 11 3/4 1,085 17 3/4 1963 23 3/4 2973 29 3/4 4080 5 7/8 403 11 7/8 1,101 17 7/8 1983 23 7/8 2996 29 7/8 4104 6 415 12 1,118 18 2002 24 3018 30 4128 Containment Solutions, Inc.1 8' 15000 DWT6 Double Wall Tank 14545 Gals DIPSTICK GALLONS DIPSTICK GALLONS DIPSTICK GALLONS DIPSTICK GALLONS DIPSTICK GALLONS 30 1/8 4152 36 1/8 5328 42 1/8 6543 48 1/8 7772 54 1/8 8992 30 1/4 4176 36 1/4 5353 42 1/4 6569 48 1/4 7798 54 1/4 9017 30 3/8 4200 36 3/8 5378 42 3/8 6594 48 3/8 7823 54 3/8 9042 30 1/2 4224 36 1/2 5403 42 1/2 6620 48 1/2 7849 54 1/2 9067 30 5/8 4248 36 5/8 5428 42 5/8 6645 48 5/8 7875 54 5/8 9092 30 3/4 4272 36 3/4 5453 42 3/4 6671 48 3/4 7900 54 3/4 9117 30 7/8 4296 36 7/8 5478 42 7/8 6696 48 7/8 7926 54 7/8 9142 31 4320 37 5504 43 6722 49 7951 55 9167 31 1/8 4344 37 1/8 5529 43 1/8 6748 49 1/8 7977 55 1/8 9192 31 1/4 4368 37 1/4 5554 43 1/4 6773 49 1/4 8002 55 1/4 9217 31 3/8 4392 37 3/8 5579 43 3/8 6799 49 3/8 8028 55 3/8 9242 31 1/2 4417 37 1/2 5604 43 1/2 6824 49 1/2 8053 55 1/2 9267 31 5/8 4441 37 5/8 5629 43 5/8 6850 49 5/8 8079 55 5/8 9292 31 3/4 4465 37 3/4 5654 43 3/4 6876 49 3/4 8104 55 3/4 9317 31 7/8 4489 37 7/8 5680 43 7/8 6901 49 7/8 8130 55 7/8 9342 32 4514 38 5705 44 6927 50 8155 56 9367 32 1/8 4538 38 1/8 5730 44 1/8 6952 50 1/8 8181 56 1/8 9392 32 1/4 4562 38 1/4 5755 44 1/4 6978 50 1/4 8206 56 1/4 9417 32 3/8 4587 38 3/8 5781 44 3/8 7004 50 3/8 8232 56 3/8 9442 32 1/2 4611 38 1/2 5806 44 1/2 7029 50 1/2 8257 56 1/2 9466 32 5/8 4636 38 5/8 5831 44 5/8 7055 50 5/8 8283 56 5/8 9491 32 3/4 4660 38 3/4 5856 44 3/4 7081 50 3/4 8308 56 3/4 9516 32 7/8 4685 38 7/8 5882 44 7/8 7106 50 7/8 8334 56 7/8 9541 33 4709 39 5907 45 7132 51 8359 57 9565 33 1/8 4734 39 1/8 5932 45 1/8 7157 51 1/8 8385 57 1/8 9590 33 1/4 4758 39 1/4 5958 45 1/4 7183 51 1/4 8410 57 1/4 9615 33 3/8 4783 39 3/8 5983 45 3/8 7209 51 3/8 8435 57 3/8 9640 33 1/2 4807 39 1/2 6008 45 1/2 7234 51 1/2 8461 57 1/2 966433 1/2 4807 39 1/2 6008 45 1/2 7234 51 1/2 8461 57 1/2 9664 33 5/8 4832 39 5/8 6034 45 5/8 7260 51 5/8 8486 57 5/8 9689 33 3/4 4857 39 3/4 6059 45 3/4 7286 51 3/4 8512 57 3/4 9714 33 7/8 4881 39 7/8 6085 45 7/8 7311 51 7/8 8537 57 7/8 9738 34 4906 40 6110 46 7337 52 8562 58 9763 34 1/8 4931 40 1/8 6135 46 1/8 7362 52 1/8 8588 58 1/8 9787 34 1/4 4955 40 1/4 6161 46 1/4 7388 52 1/4 8613 58 1/4 9812 34 3/8 4980 40 3/8 6186 46 3/8 7414 52 3/8 8638 58 3/8 9836 34 1/2 5005 40 1/2 6212 46 1/2 7439 52 1/2 8664 58 1/2 9861 34 5/8 5030 40 5/8 6237 46 5/8 7465 52 5/8 8689 58 5/8 9885 34 3/4 5054 40 3/4 6263 46 3/4 7491 52 3/4 8714 58 3/4 9910 34 7/8 5079 40 7/8 6288 46 7/8 7516 52 7/8 8740 58 7/8 9934 35 5104 41 6314 47 7542 53 8765 59 9959 35 1/8 5129 41 1/8 6339 47 1/8 7567 53 1/8 8790 59 1/8 9983 35 1/4 5154 41 1/4 6365 47 1/4 7593 53 1/4 8815 59 1/4 10007 35 3/8 5179 41 3/8 6390 47 3/8 7619 53 3/8 8841 59 3/8 10032 35 1/2 5203 41 1/2 6416 47 1/2 7644 53 1/2 8866 59 1/2 10056 35 5/8 5228 41 5/8 6441 47 5/8 7670 53 5/8 8891 59 5/8 10080 35 3/4 5253 41 3/4 6467 47 3/4 7695 53 3/4 8916 59 3/4 10105 35 7/8 5278 41 7/8 6492 47 7/8 7721 53 7/8 8941 59 7/8 10129 36 5303 42 6518 48 7747 54 8967 60 10153 Containment Solutions, Inc.2 8' 15000 DWT6 Double Wall Tank 14545 Gals DIPSTICK GALLONS DIPSTICK GALLONS DIPSTICK GALLONS DIPSTICK GALLONS DIPSTICK GALLONS 60 1/8 10177 66 1/8 11303 72 1/8 12341 78 1/8 13256 84 1/8 14,003 60 1/4 10201 66 1/4 11326 72 1/4 12361 78 1/4 13274 84 1/4 14,016 60 3/8 10225 66 3/8 11348 72 3/8 12382 78 3/8 13291 84 3/8 14,029 60 1/2 10250 66 1/2 11371 72 1/2 12402 78 1/2 13308 84 1/2 14,042 60 5/8 10274 66 5/8 11393 72 5/8 12422 78 5/8 13326 84 5/8 14,055 60 3/4 10298 66 3/4 11416 72 3/4 12443 78 3/4 13343 84 3/4 14,068 60 7/8 10322 66 7/8 11438 72 7/8 12463 78 7/8 13360 84 7/8 14,081 61 10346 67 11461 73 12483 79 13377 85 14,093 61 1/8 10370 67 1/8 11483 73 1/8 12503 79 1/8 13394 85 1/8 14,106 61 1/4 10394 67 1/4 11505 73 1/4 12523 79 1/4 13411 85 1/4 14,118 61 3/8 10418 67 3/8 11528 73 3/8 12543 79 3/8 13428 85 3/8 14,131 61 1/2 10441 67 1/2 11550 73 1/2 12563 79 1/2 13444 85 1/2 14,143 61 5/8 10465 67 5/8 11572 73 5/8 12583 79 5/8 13461 85 5/8 14,155 61 3/4 10489 67 3/4 11594 73 3/4 12603 79 3/4 13477 85 3/4 14,167 61 7/8 10513 67 7/8 11616 73 7/8 12622 79 7/8 13494 85 7/8 14,179 62 10537 68 11638 74 12642 80 13510 86 14,190 62 1/8 10560 68 1/8 11660 74 1/8 12662 80 1/8 13527 86 1/8 14,202 62 1/4 10584 68 1/4 11682 74 1/4 12681 80 1/4 13543 86 1/4 14,213 62 3/8 10608 68 3/8 11704 74 3/8 12701 80 3/8 13559 86 3/8 14,225 62 1/2 10632 68 1/2 11726 74 1/2 12720 80 1/2 13575 86 1/2 14,236 62 5/8 10655 68 5/8 11748 74 5/8 12739 80 5/8 13591 86 5/8 14,247 62 3/4 10679 68 3/4 11770 74 3/4 12759 80 3/4 13607 86 3/4 14,258 62 7/8 10702 68 7/8 11792 74 7/8 12778 80 7/8 13623 86 7/8 14,269 63 10726 69 11813 75 12797 81 13639 87 14,279 63 1/8 10749 69 1/8 11835 75 1/8 12816 81 1/8 13654 87 1/8 14,290 63 1/4 10773 69 1/4 11857 75 1/4 12835 81 1/4 13670 87 1/4 14,300 63 3/8 10796 69 3/8 11878 75 3/8 12854 81 3/8 13685 87 3/8 14,310 63 1/2 10820 69 1/2 11900 75 1/2 12873 81 1/2 13701 87 1/2 14,32163 1/2 10820 69 1/2 11900 75 1/2 12873 81 1/2 13701 87 1/2 14,321 63 5/8 10843 69 5/8 11921 75 5/8 12892 81 5/8 13716 87 5/8 14,331 63 3/4 10866 69 3/4 11943 75 3/4 12911 81 3/4 13731 87 3/4 14,340 63 7/8 10890 69 7/8 11964 75 7/8 12930 81 7/8 13746 87 7/8 14,350 64 10913 70 11985 76 12949 82 13761 88 14,360 64 1/8 10936 70 1/8 12007 76 1/8 12967 82 1/8 13776 88 1/8 14,369 64 1/4 10959 70 1/4 12028 76 1/4 12986 82 1/4 13791 88 1/4 14,378 64 3/8 10983 70 3/8 12049 76 3/8 13004 82 3/8 13806 88 3/8 14,387 64 1/2 11006 70 1/2 12070 76 1/2 13023 82 1/2 13821 88 1/2 14,396 64 5/8 11029 70 5/8 12092 76 5/8 13041 82 5/8 13835 88 5/8 14,405 64 3/4 11052 70 3/4 12113 76 3/4 13059 82 3/4 13850 88 3/4 14,413 64 7/8 11075 70 7/8 12134 76 7/8 13078 82 7/8 13864 88 7/8 14,421 65 11098 71 12155 77 13096 83 13878 89 14,430 65 1/8 11121 71 1/8 12175 77 1/8 13114 83 1/8 13893 89 1/8 14,438 65 1/4 11144 71 1/4 12196 77 1/4 13132 83 1/4 13907 89 1/4 14,445 65 3/8 11167 71 3/8 12217 77 3/8 13150 83 3/8 13921 89 3/8 14,453 65 1/2 11189 71 1/2 12238 77 1/2 13168 83 1/2 13935 89 1/2 14,460 65 5/8 11212 71 5/8 12259 77 5/8 13186 83 5/8 13948 89 5/8 14,468 65 3/4 11235 71 3/4 12279 77 3/4 13203 83 3/4 13962 89 3/4 14,474 65 7/8 11258 71 7/8 12300 77 7/8 13221 83 7/8 13976 89 7/8 14,481 66 11281 72 12320 78 13239 84 13989 90 14,488 Containment Solutions, Inc.3 8' 15000 DWT6 Double Wall Tank 14545 Gals DIPSTICK GALLONS 90 1/8 14,494 90 1/4 14,500 90 3/8 14,506 90 1/2 14,511 90 5/8 14,517 90 3/4 14,522 90 7/8 14,526 91 14,530 91 1/8 14,534 91 1/4 14,538 91 3/8 14,541 91 1/2 14,543 91 5/8 14,545 HOW TO PROPERLY GAUGE YOUR TANK: Underground storage tanks require periodic measurement to determine current inventory level. Using the proper methods when gauging your tank's contents will insure the most accurate reading and insure that you do not damage your tank. The following procedure should be followed whenever you use a gauge stick to determine the amount of product that is in your tank: 1) Use a wood dipstick with a rubber or nylon tip. Metallic dipsticks are not recommended. This will insure that frequent tank gaugings or an accidental dropping of the gauge stick into the tank will not damage the tank bottom. 2) Slowly lower your gauge stick into the fill port until it touches the tank bottom. Never free drop the gauge stick. This can result in inaccurate measurements due to product splashing. Free dropping can also result in gauge stick damage and tank damage. 3) Remove your dipstick slowly and read the product level directly from the gauge stick. Water Paste Detection To detect water in the tank bottom, water detection paste is available from petroleum equipment distributors. However, some water detection paste cannot detect antifreeze mixtures. If antifreeze mixtures are used for the cavity monitoring fluid, the following product is capable of detecting water or antifreeze (brine or up to 50 percent glycol) solution in the tank water bottoms: WATER FINDER #7686:1870 DAYCO/NATIONAL DAYTON, OH TEL: 1:800:283:2926 FAX: 1:800:688:4854 Caution Pressurized deliveries are not recommended. If the delivery vehicle uses pumps to fill the tank, install overfill shutoff equipment in the tank and truck to prevent the tank from being overfilled.Overfilling the tank undershutoffequipmentinthetankandtrucktopreventthetankfrombeingoverfilled.Overfilling the tank under pressure will damage the tank even if the tank vent is unrestricted. Containment Solutions, Inc. 5150 Jefferson Chemical Road Conroe, TX 77301 Tel: 936 756 7731 Fax: 936 756 7766 Note: Calibration chart is based on the fluid level above a 5/16" deflector plate. Containment Solutions, Inc.4 8' 10000 DWT6 Double Wall Tank 9696 Gals DIPSTICK GALLONS DIPSTICK GALLONS DIPSTICK GALLONS DIPSTICK GALLONS DIPSTICK GALLONS 1/8 5 6 1/8 278 12 1/8 743 18 1/8 1330 24 1/8 2008 1/4 7 6 1/4 286 12 1/4 754 18 1/4 1343 24 1/4 2023 3/8 10 6 3/8 294 12 3/8 765 18 3/8 1357 24 3/8 2037 1/2 12 6 1/2 303 12 1/2 776 18 1/2 1370 24 1/2 2052 5/8 15 6 5/8 311 12 5/8 787 18 5/8 1383 24 5/8 2067 3/4 19 6 3/4 319 12 3/4 799 18 3/4 1397 24 3/4 2082 7/8 22 6 7/8 328 12 7/8 810 18 7/8 1410 24 7/8 2097 1 26 7 336 13 821 19 1424 25 2112 1 1/8 29 7 1/8 345 13 1/8 833 19 1/8 1437 25 1/8 2128 1 1/4 33 7 1/4 354 13 1/4 844 19 1/4 1451 25 1/4 2143 1 3/8 37 7 3/8 362 13 3/8 856 19 3/8 1465 25 3/8 2158 1 1/2 42 7 1/2 371 13 1/2 868 19 1/2 1478 25 1/2 2173 1 5/8 46 7 5/8 380 13 5/8 879 19 5/8 1492 25 5/8 2188 1 3/4 50 7 3/4 389 13 3/4 891 19 3/4 1506 25 3/4 2203 1 7/8 55 7 7/8 398 13 7/8 903 19 7/8 1519 25 7/8 2219 2 60 8 407 14 915 20 1533 26 2234 2 1/8 65 8 1/8 416 14 1/8 927 20 1/8 1547 26 1/8 2249 2 1/4 70 8 1/4 426 14 1/4 938 20 1/4 1561 26 1/4 2265 2 3/8 75 8 3/8 435 14 3/8 950 20 3/8 1575 26 3/8 2280 2 1/2 80 8 1/2 444 14 1/2 962 20 1/2 1589 26 1/2 2295 2 5/8 86 8 5/8 454 14 5/8 974 20 5/8 1603 26 5/8 2311 2 3/4 91 8 3/4 463 14 3/4 987 20 3/4 1617 26 3/4 2326 2 7/8 97 8 7/8 473 14 7/8 999 20 7/8 1631 26 7/8 2342 3 103 9 483 15 1011 21 1645 27 2357 3 1/8 109 9 1/8 492 15 1/8 1,023 21 1/8 1659 27 1/8 2373 3 1/4 115 9 1/4 502 15 1/4 1,035 21 1/4 1673 27 1/4 2388 3 3/8 121 9 3/8 512 15 3/8 1,048 21 3/8 1687 27 3/8 2404 3 1/2 127 9 1/2 522 15 1/2 1,060 21 1/2 1702 27 1/2 2419 3 5/8 133 9 5/8 532 15 5/8 1,073 21 5/8 1716 27 5/8 2435 3 3/4 140 9 3/4 542 15 3/4 1,085 21 3/4 1730 27 3/4 2450 3 7/8 146 9 7/8 552 15 7/8 1,098 21 7/8 1745 27 7/8 2466 4 153 10 562 16 1,110 22 1759 28 2482 4 1/8 159 10 1/8 572 16 1/8 1,123 22 1/8 1773 28 1/8 2497 4 1/4 166 10 1/4 582 16 1/4 1,135 22 1/4 1788 28 1/4 2513 4 3/8 173 10 3/8 593 16 3/8 1,148 22 3/8 1802 28 3/8 2529 4 1/2 180 10 1/2 603 16 1/2 1,161 22 1/2 1817 28 1/2 2545 4 5/8 187 10 5/8 613 16 5/8 1,174 22 5/8 1831 28 5/8 2560 4 3/4 194 10 3/4 624 16 3/4 1,186 22 3/4 1846 28 3/4 2576 4 7/8 201 10 7/8 634 16 7/8 1199 22 7/8 1860 28 7/8 2592 5 209 11 645 17 1212 23 1875 29 2608 5 1/8 216 11 1/8 655 17 1/8 1225 23 1/8 1889 29 1/8 2624 5 1/4 223 11 1/4 666 17 1/4 1238 23 1/4 1904 29 1/4 2640 5 3/8 231 11 3/8 677 17 3/8 1251 23 3/8 1919 29 3/8 2655 5 1/2 239 11 1/2 688 17 1/2 1264 23 1/2 1934 29 1/2 2671 5 5/8 246 11 5/8 699 17 5/8 1277 23 5/8 1948 29 5/8 2687 5 3/4 254 11 3/4 709 17 3/4 1290 23 3/4 1963 29 3/4 2703 5 7/8 262 11 7/8 720 17 7/8 1303 23 7/8 1978 29 7/8 2719 6 270 12 731 18 1317 24 1993 30 2735 Containment Solutions, Inc.1 8' 10000 DWT6 Double Wall Tank 9696 Gals DIPSTICK GALLONS DIPSTICK GALLONS DIPSTICK GALLONS DIPSTICK GALLONS DIPSTICK GALLONS 30 1/8 2751 36 1/8 3541 42 1/8 4357 48 1/8 5184 54 1/8 6004 30 1/4 2767 36 1/4 3557 42 1/4 4375 48 1/4 5201 54 1/4 6021 30 3/8 2783 36 3/8 3574 42 3/8 4392 48 3/8 5218 54 3/8 6038 30 1/2 2800 36 1/2 3591 42 1/2 4409 48 1/2 5236 54 1/2 6055 30 5/8 2816 36 5/8 3608 42 5/8 4426 48 5/8 5253 54 5/8 6071 30 3/4 2832 36 3/4 3625 42 3/4 4443 48 3/4 5270 54 3/4 6088 30 7/8 2848 36 7/8 3642 42 7/8 4460 48 7/8 5287 54 7/8 6105 31 2864 37 3658 43 4478 49 5304 55 6122 31 1/8 2880 37 1/8 3675 43 1/8 4495 49 1/8 5322 55 1/8 6139 31 1/4 2896 37 1/4 3692 43 1/4 4512 49 1/4 5339 55 1/4 6156 31 3/8 2913 37 3/8 3709 43 3/8 4529 49 3/8 5356 55 3/8 6172 31 1/2 2929 37 1/2 3726 43 1/2 4547 49 1/2 5373 55 1/2 6189 31 5/8 2945 37 5/8 3743 43 5/8 4564 49 5/8 5390 55 5/8 6206 31 3/4 2961 37 3/4 3760 43 3/4 4581 49 3/4 5408 55 3/4 6223 31 7/8 2978 37 7/8 3777 43 7/8 4598 49 7/8 5425 55 7/8 6239 32 2994 38 3794 44 4615 50 5442 56 6256 32 1/8 3010 38 1/8 3811 44 1/8 4633 50 1/8 5459 56 1/8 6273 32 1/4 3027 38 1/4 3828 44 1/4 4650 50 1/4 5476 56 1/4 6289 32 3/8 3043 38 3/8 3845 44 3/8 4667 50 3/8 5493 56 3/8 6306 32 1/2 3059 38 1/2 3862 44 1/2 4684 50 1/2 5510 56 1/2 6323 32 5/8 3076 38 5/8 3879 44 5/8 4702 50 5/8 5527 56 5/8 6339 32 3/4 3092 38 3/4 3896 44 3/4 4719 50 3/4 5545 56 3/4 6356 32 7/8 3109 38 7/8 3913 44 7/8 4736 50 7/8 5562 56 7/8 6373 33 3125 39 3930 45 4753 51 5579 57 6389 33 1/8 3141 39 1/8 3947 45 1/8 4771 51 1/8 5596 57 1/8 6406 33 1/4 3158 39 1/4 3964 45 1/4 4788 51 1/4 5613 57 1/4 6423 33 3/8 3174 39 3/8 3981 45 3/8 4805 51 3/8 5630 57 3/8 6439 33 1/2 3191 39 1/2 3998 45 1/2 4822 51 1/2 5647 57 1/2 6456 33 5/8 3207 39 5/8 4015 45 5/8 4839 51 5/8 5664 57 5/8 6472 33 3/4 3224 39 3/4 4032 45 3/4 4857 51 3/4 5681 57 3/4 6489 33 7/8 3240 39 7/8 4049 45 7/8 4874 51 7/8 5698 57 7/8 6505 34 3257 40 4066 46 4891 52 5715 58 6522 34 1/8 3274 40 1/8 4083 46 1/8 4908 52 1/8 5732 58 1/8 6538 34 1/4 3290 40 1/4 4100 46 1/4 4926 52 1/4 5749 58 1/4 6555 34 3/8 3307 40 3/8 4117 46 3/8 4943 52 3/8 5767 58 3/8 6571 34 1/2 3323 40 1/2 4134 46 1/2 4960 52 1/2 5784 58 1/2 6588 34 5/8 3340 40 5/8 4152 46 5/8 4977 52 5/8 5801 58 5/8 6604 34 3/4 3357 40 3/4 4169 46 3/4 4995 52 3/4 5818 58 3/4 6620 34 7/8 3373 40 7/8 4186 46 7/8 5012 52 7/8 5835 58 7/8 6637 35 3390 41 4203 47 5029 53 5852 59 6653 35 1/8 3407 41 1/8 4220 47 1/8 5046 53 1/8 5868 59 1/8 6670 35 1/4 3423 41 1/4 4237 47 1/4 5064 53 1/4 5885 59 1/4 6686 35 3/8 3440 41 3/8 4254 47 3/8 5081 53 3/8 5902 59 3/8 6702 35 1/2 3457 41 1/2 4271 47 1/2 5098 53 1/2 5919 59 1/2 6718 35 5/8 3474 41 5/8 4289 47 5/8 5115 53 5/8 5936 59 5/8 6735 35 3/4 3490 41 3/4 4306 47 3/4 5132 53 3/4 5953 59 3/4 6751 35 7/8 3507 41 7/8 4323 47 7/8 5150 53 7/8 5970 59 7/8 6767 36 3524 42 4340 48 5167 54 5987 60 6784 Containment Solutions, Inc.2 8' 10000 DWT6 Double Wall Tank 9696 Gals DIPSTICK GALLONS DIPSTICK GALLONS DIPSTICK GALLONS DIPSTICK GALLONS DIPSTICK GALLONS 60 1/8 6800 66 1/8 7553 72 1/8 8245 78 1/8 8852 84 1/8 9,342 60 1/4 6816 66 1/4 7569 72 1/4 8259 78 1/4 8863 84 1/4 9,351 60 3/8 6832 66 3/8 7584 72 3/8 8272 78 3/8 8875 84 3/8 9,360 60 1/2 6848 66 1/2 7599 72 1/2 8286 78 1/2 8886 84 1/2 9,368 60 5/8 6864 66 5/8 7614 72 5/8 8299 78 5/8 8898 84 5/8 9,377 60 3/4 6881 66 3/4 7629 72 3/4 8313 78 3/4 8909 84 3/4 9,385 60 7/8 6897 66 7/8 7644 72 7/8 8326 78 7/8 8920 84 7/8 9,394 61 6913 67 7659 73 8340 79 8931 85 9,402 61 1/8 6929 67 1/8 7674 73 1/8 8353 79 1/8 8943 85 1/8 9,410 61 1/4 6945 67 1/4 7689 73 1/4 8366 79 1/4 8954 85 1/4 9,418 61 3/8 6961 67 3/8 7703 73 3/8 8379 79 3/8 8965 85 3/8 9,426 61 1/2 6977 67 1/2 7718 73 1/2 8393 79 1/2 8976 85 1/2 9,434 61 5/8 6993 67 5/8 7733 73 5/8 8406 79 5/8 8987 85 5/8 9,442 61 3/4 7009 67 3/4 7748 73 3/4 8419 79 3/4 8998 85 3/4 9,450 61 7/8 7025 67 7/8 7763 73 7/8 8432 79 7/8 9008 85 7/8 9,458 62 7041 68 7777 74 8445 80 9019 86 9,465 62 1/8 7057 68 1/8 7792 74 1/8 8458 80 1/8 9030 86 1/8 9,473 62 1/4 7072 68 1/4 7807 74 1/4 8471 80 1/4 9041 86 1/4 9,480 62 3/8 7088 68 3/8 7821 74 3/8 8484 80 3/8 9051 86 3/8 9,488 62 1/2 7104 68 1/2 7836 74 1/2 8497 80 1/2 9062 86 1/2 9,495 62 5/8 7120 68 5/8 7850 74 5/8 8510 80 5/8 9072 86 5/8 9,502 62 3/4 7136 68 3/4 7865 74 3/4 8523 80 3/4 9083 86 3/4 9,509 62 7/8 7152 68 7/8 7880 74 7/8 8535 80 7/8 9093 86 7/8 9,516 63 7167 69 7894 75 8548 81 9104 87 9,523 63 1/8 7183 69 1/8 7908 75 1/8 8561 81 1/8 9114 87 1/8 9,530 63 1/4 7199 69 1/4 7923 75 1/4 8573 81 1/4 9124 87 1/4 9,537 63 3/8 7214 69 3/8 7937 75 3/8 8586 81 3/8 9134 87 3/8 9,544 63 1/2 7230 69 1/2 7952 75 1/2 8599 81 1/2 9144 87 1/2 9,550 63 5/8 7246 69 5/8 7966 75 5/8 8611 81 5/8 9155 87 5/8 9,557 63 3/4 7261 69 3/4 7980 75 3/4 8624 81 3/4 9165 87 3/4 9,563 63 7/8 7277 69 7/8 7994 75 7/8 8636 81 7/8 9174 87 7/8 9,569 64 7293 70 8009 76 8648 82 9184 88 9,575 64 1/8 7308 70 1/8 8023 76 1/8 8661 82 1/8 9194 88 1/8 9,582 64 1/4 7324 70 1/4 8037 76 1/4 8673 82 1/4 9204 88 1/4 9,588 64 3/8 7339 70 3/8 8051 76 3/8 8685 82 3/8 9214 88 3/8 9,593 64 1/2 7355 70 1/2 8065 76 1/2 8697 82 1/2 9223 88 1/2 9,599 64 5/8 7370 70 5/8 8079 76 5/8 8710 82 5/8 9233 88 5/8 9,605 64 3/4 7385 70 3/4 8093 76 3/4 8722 82 3/4 9242 88 3/4 9,610 64 7/8 7401 70 7/8 8107 76 7/8 8734 82 7/8 9252 88 7/8 9,616 65 7416 71 8121 77 8746 83 9261 89 9,621 65 1/8 7432 71 1/8 8135 77 1/8 8758 83 1/8 9270 89 1/8 9,626 65 1/4 7447 71 1/4 8149 77 1/4 8770 83 1/4 9280 89 1/4 9,631 65 3/8 7462 71 3/8 8163 77 3/8 8781 83 3/8 9289 89 3/8 9,636 65 1/2 7477 71 1/2 8177 77 1/2 8793 83 1/2 9298 89 1/2 9,641 65 5/8 7493 71 5/8 8190 77 5/8 8805 83 5/8 9307 89 5/8 9,646 65 3/4 7508 71 3/4 8204 77 3/4 8817 83 3/4 9316 89 3/4 9,650 65 7/8 7523 71 7/8 8218 77 7/8 8828 83 7/8 9325 89 7/8 9,655 66 7538 72 8232 78 8840 84 9334 90 9,659 Containment Solutions, Inc.3 8' 10000 DWT6 Double Wall Tank 9696 Gals DIPSTICK GALLONS 90 1/8 9,663 90 1/4 9,667 90 3/8 9,671 90 1/2 9,674 90 5/8 9,677 90 3/4 9,681 90 7/8 9,684 91 9,686 91 1/8 9,689 91 1/4 9,691 91 3/8 9,693 91 1/2 9,695 91 5/8 9,696 HOW TO PROPERLYGAUGE YOUR TANK: Underground storage tanks require periodic measurement to determine current inventory level. Using the proper methods when gauging your tank's contents will insure the most accurate reading and insure that you do not damage your tank. The following procedure should be followed whenever you use a gauge stick to determine the amount of product that is in your tank: 1) Use a wood dipstick with a rubber or nylon tip. Metallic dipsticks are not recommended. This will insure that frequent tank gaugings or an accidental dropping of the gauge stick into the tank will not damage the tank bottom. 2) Slowly lower your gauge stick into the fill port until it touches the tank bottom. Never free drop the gauge stick. This can result in inaccurate measurements due to product splashing. Free dropping can also result in gauge stick damage and tank damage. 3) Remove your dipstick slowly and read the product level directly from the gauge stick. Water Paste Detection: To detect water in the tank bottom, water detection paste is available from petroleum equipment distributors. See vendor below or suitable equal. Gasoila Water Finding Paste Federal Process Corp. 800584657325 www.gasoila.com Caution Pressurized deliveries are not recommended. If the delivery vehicle uses pumps to fill the tank, install overfill shutoff equipment in the tank and truck to prevent the tank from being overfilled.Overfilling the tank under pressure will damage the tank even if the tank vent is unrestricted. Containment Solutions, Inc. 5150 Jefferson Chemical Road Conroe,TX 77301 Tel: 936 756 7731 Fax: 936 756 7766 Note: Calibration chart is based on the fluid level above a 5/16" deflector plate. Containment Solutions, Inc.4