Loading...
HomeMy WebLinkAboutApplication FMC 2021_10_13_4-8UNDERGROUND STORAGE TANKS APPLICATION TO PERFORM ELD/LINE TESTING/ SB989 SECONDARY CONTAINMENT TESTING/TANK TIGHTNESS TEST AND FUEL MONITORING CERTIFICATION (Please note that these are separate individual tests and will be charged per separate type test accordingly.) PERMIT # ❑ ENHANCED LEAK DETECTION ❑ TANK TIGHTNESS ❑ LINE TESTING X FUEL MONITORING CERTIFICATION BAKERSFIELD FIRE DEPARTMENT Prevention Services 2101 H Street Bakersfield, CA 93301 Phone: 661-326-3979 • Fax: 661-852-2171 Page 1 of 1 ❑ SB -989 SECONDARY CONTAINMENT OVERFILL PREVENTION SITE INFORMATION FACILITY 'CIRCLE K # 2708605 NAME & PHONE # OF CONTACT PERSON YOLANDA JONES 602-728-8000 EXT 5287 ADDRESS 5600 AUBURN ST BAKERSFIELD OWNER NAME CIRCLE K STORES INC OPERATOR NAME CIRCLE K PERMIT TO OPERATE # # OF TANKS TO BE TESTED: IS PIPING GOING TO BE TESTED? ❑ YES ❑ NO TANK # VOLUME CONTENTS TANK TESTING COMPANY TESTING COMPANY B&T SERVICE STATION CONTRACTORS NAME & PHONE # OF CONTACT PERSON MAILING ADDRESS 630 S FRONTAGE RD NIPOMO, CA 93444 NAME & PHONE # OF TESTER OR SPECIAL INSPECTOR RICKEY BINGER 805-431-0332 CERTIFICATION # TEST METHOD ICC # INDUSRTY STANDARD _ 8452629 APPLICANT SIGNATURE, DATE 9/1/2021 THIS APPLICATION BECOMES A PERMIT WHEN APPROVED APPROVED BY DATE FD2095 (Rev 03/18)