Loading...
HomeMy WebLinkAbout2021-10-12-2701270-MC Appendix VI Underground Storage Tank Monitoring System Certification Form CERS = California Environmental Reporting System, GPH = Gallons Per Hour, ID = Identification, ICC = International Code Council, LLD = Line Leak Detector, NA = Not Applicable, SW = Single-Walled, UDC = Under-Dispenser Containment, UST = Underground Storage Tank, VPH = Vacuum/Pressure/Hydrostatic Page 1 of 6 TYPE OF ACTION ☐ Installation ☐ Repair ☒ 12 Month 1. FACILITY INFORMATION CERS ID 10022869 Certification Date 10/12/2021 Facility Name Circle k Facility Address 5634 Stine rd City Bakersfield ZIP Code 2. SERVICE TECHNICIAN INFORMATION Company Performing the Certification B&T Service Station Contractors Phone 805-929-8944 Mailing Address 630 S. Frontage rd Nipomo Service Technician Performing Test Rick Binger Contractor/Tank Tester License Number 902034 ICC Number 8452629 ICC Expiration Date 3/31/2023 3. TRAINING AND CERTIFICATIONS Manufacturer and Test Equipment Training Certifications Expiration Date Veeder Root B47631 05/09/2023 Redjacket B47631 02/07/2023 VMI 3950 11/16/2022 4. CERTIFICATION BY SERVICE TECHNICIAN CONDUCTING TEST I hereby certify that the monitoring system is operational in accordance with California Code of Regulations, title 23, division 3, chapter 16, section 2638; that required supporting documentation is attached; and all information contained herein is accurate. Service Technician Signature Date 10/12/2021 Total # of Pages Underground Storage Tank Monitoring System Certification Form Page 2 of 6 5. MONITORING SYSTEM AND PROGRAMMING A separate Monitoring System Certification Form must be prepared for each control panel. Make of Monitoring System Control Panel Veeder Root Model of Monitoring System Control Panel TLS-350 Software Version Installed 335.00 Attach the post-certification reports if the monitoring system is capable of generating either; ☒Monitoring System Set-up ☒ Alarm History Report Yes No NA All monitoring equipment is operational per manufacturer’s specifications? ☒ ☐ Secondary containment systems are free of damage, debris, or liquid? ☒ ☐ Are the audible and visual alarms operational? ☒ ☐ All sensors have been: 1) visually inspected for wiring kinks, breaks and residual buildup on floats; and 2) tested for functionality and confirmed operational? ☒ ☐ ☐ Are all sensors installed to detect a release at the earliest opportunity in the secondary containment? ☒ ☐ ☐ The monitoring system set-up was reviewed, and proper settings confirmed? ☒ ☐ ☐ Was the monitoring control panel’s backup battery visually inspected, functionally tested, and confirmed operational? ☒ ☐ ☐ Does the flow of fuel stop at the dispenser if a release is detected in the under-dispenser containment? ☒ ☐ ☐ Does the turbine automatically shut down if the piping secondary containment monitoring system fails to operate or is electrically disconnected? ☒ ☐ ☐ Does the turbine automatically shut down if the piping secondary containment monitoring system detects a release? Which sensors initiate positive shut down? (Check all that apply) ☒ Sump ☐ UDC ☒ ☐ ☐ If monitoring system alarms are relayed to a remote monitoring center, is all communication equipment operational? ☒ ☐ ☐ Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 Underground Storage Tank Monitoring System Certification Form Page 3 of 6 6. SENSOR TESTING RESULTS List only sensors tested on date of this certification. List “Sensor ID” as labeled in system programming. Additional copies of this page may be attached to accommodate all sensors tested. Sensor ID Sensor Model Component(s) Monitored Pass Fail L1 794390-409 87 Annular ☒ ☐ L2 794380-208 87 Turbine Sump ☒ ☐ L3 794390-409 91 Annular ☒ ☐ L4 794380-208 91 Turbine Sump ☒ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 Underground Storage Tank Monitoring System Certification Form Page 4 of 6 7. LINE LEAK DETECTOR TESTING ☐ Check this box if line leak detectors ARE NOT installed. (Do not complete this section.) Simulated release rate verified: (Check all that apply.) ☒ 3 GPH ☐ 0.1 GPH ☐ 0.2 GPH Yes No NA Has the testing apparatus been properly calibrated? ☒ ☐ ☐ For emergency generator tank systems, does the LLD create an audible and visual alarm when a leak is detected? ☐ ☐ ☒ For mechanical LLDs, does the LLD restrict the flow through the pipe when a release is detected? ☒ ☐ ☐ For electronic LLDs, does the turbine automatically shut off when a release is detected? ☐ ☐ ☒ For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system is disabled or disconnected? ☐ ☐ ☒ For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system malfunctions or fails a tightness test? ☐ ☐ ☒ For electronic LLDs, have all accessible wiring connections been visually inspected for kinks and breaks? ☐ ☐ ☒ Were all items on the equipment manufacturer’s maintenance checklist completed? ☒ ☐ ☐ Were all LLDs confirmed operational within regulatory requirements? ☒ ☐ ☐ LLD ID LLD Model Lines Monitored Pass Fail Tank 1 VMI LD2000 87 ☒ ☐ Tank 2 VMI LD2000 91 ☒ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 Underground Storage Tank Monitoring System Certification Form Page 5 of 6 8. IN-TANK GAUGING TESTING ☐ Check this box if tank gauging is used only for inventory control. ☒ Check this box if NO tank gauging equipment is installed. (Do not complete this section if either box is checked.) Yes No NA All wiring has been: 1) visually inspected for kinks, breaks and proper entry and termination; and 2) tested for ground faults? ☐ ☐ ☐ Were all in-tank gauging probes visually inspected for damage and residue buildup to ensure that floats move freely, functionally tested, and confirmed operational? ☐ ☐ ☐ Was accuracy of system’s product level readings tested? ☐ ☐ ☐ Was accuracy of system’s water level readings tested? ☐ ☐ ☐ Were all probes reinstalled properly? ☐ ☐ ☐ Were all items on the equipment manufacturer’s maintenance checklist completed? ☐ ☐ ☐ Probe ID Probe Model Tanks Monitored Pass Fail ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ 9. COMMENTS Describe all answers marked “No” or “Fail” and proposed remedy. List all monitoring equipment either replaced or repaired. < I10100 OCT 12, 2021 11:49 AM CIRCLE K 2701270 5634 STINE RD. BAKERSFIELD, CA 80749873405001 SYSTEM STATUS REPORT ALL FUNCTIONS NORMAL > < I51700 OCT 12, 2021 11:49 AM SYSTEM TYPE AND LANGUAGE FLAG SYSTEM UNITS U.S. SYSTEM LANGUAGE ENGLISH SYSTEM DATE/TIME FORMAT MON DD YYYY HH:MM:SS xM > < I50F00 OCT 12, 2021 11:49 AM MON DD YYYY HH:MM:SS xM > < I60100 OCT 12, 2021 11:49 AM TANK CONFIGURATION DEVICE LABEL CONFIGURED 1 UNL-REG(005) ON 2 UNL-PREM ON 3 OFF 4 OFF > < I60200 OCT 12, 2021 11:49 AM TANK PRODUCT LABEL TANK PRODUCT LABEL 1 UNL-REG(005) 2 UNL-PREM 3 4 > < I60300 OCT 12, 2021 11:49 AM TANK PRODUCT CODE TANK PRODUCT LABEL 1 UNL-REG(005) A 2 UNL-PREM B 3 3 4 4 > < I60400 OCT 12, 2021 11:49 AM TANK FULL VOLUME TANK PRODUCT LABEL GALLONS 1 UNL-REG(005) 14425 2 UNL-PREM 11849 3 0 4 0 > < I60700 OCT 12, 2021 11:49 AM TANK DIAMETER TANK PRODUCT LABEL INCHES 1 UNL-REG(005) 117.75 2 UNL-PREM 117.75 3 0.00 4 0.00 > < I60900 OCT 12, 2021 11:49 AM TANK THERMAL COEFFICIENT TANK PRODUCT LABEL 1 UNL-REG(005) 0.000700 2 UNL-PREM 0.000700 3 0.000000 4 0.000000 > < I61200 OCT 12, 2021 11:49 AM TANK MANIFOLDED PARTNERS TANK PRODUCT LABEL SIPHON MANIFOLDED TANKS LINE MANIFOLDED TANKS 1 UNL-REG(005) NONE NONE 2 UNL-PREM NONE NONE 3 NONE NONE 4 NONE NONE > < I62100 OCT 12, 2021 11:49 AM TANK LOW PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 UNL-REG(005) 1084 2 UNL-PREM 900 3 0 4 0 > < I62200 OCT 12, 2021 11:49 AM TANK HIGH PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 UNL-REG(005) 13704 2 UNL-PREM 11257 3 0 4 0 > < I62300 OCT 12, 2021 11:49 AM TANK OVERFILL LEVEL LIMIT TANK PRODUCT LABEL GALLONS 1 UNL-REG(005) 12983 2 UNL-PREM 10664 3 0 4 0 > < I62400 OCT 12, 2021 11:49 AM TANK HIGH WATER LEVEL LIMIT TANK PRODUCT LABEL INCHES 1 UNL-REG(005) 2.5 2 UNL-PREM 2.5 > < I62800 OCT 12, 2021 11:49 AM TANK MAXIMUM VOLUME LIMIT TANK PRODUCT LABEL GALLONS 1 UNL-REG(005) 14425 2 UNL-PREM 11849 3 0 4 0 > < I62900 OCT 12, 2021 11:49 AM TANK DELIVERY REQUIRED LIMIT TANK PRODUCT LABEL GALLONS 1 UNL-REG(005) 749 2 UNL-PREM 948 3 0 4 0 > < I70300 OCT 12, 2021 11:50 AM LIQUID TYPE SENSOR LOCATION TYPE 1 87 ANNULAR TRI-STATE (SINGLE FLOAT) 2 87 TURBINE TRI-STATE (SINGLE FLOAT) 3 91 ANNULAR TRI-STATE (SINGLE FLOAT) 4 91 TURBINE TRI-STATE (SINGLE FLOAT) 5 TRI-STATE (SINGLE FLOAT) 6 TRI-STATE (SINGLE FLOAT) 7 TRI-STATE (SINGLE FLOAT) 8 TRI-STATE (SINGLE FLOAT) > < I20600 OCT 12, 2021 11:50 AM CIRCLE K 2701270 5634 STINE RD. BAKERSFIELD, CA 80749873405001 TANK ALARM HISTORY TANK 1 UNL-REG(005) SETUP DATA WARNING OCT 8, 2020 11:23 PM SEP 22, 2020 5:39 AM LOW PRODUCT ALARM MAR 17, 2021 1:25 PM MAR 8, 2021 4:50 PM MAR 6, 2021 10:38 PM TANK 2 UNL-PREM TANK 5 TANK 6 TANK 7 TANK 8 TANK 9 TANK 10 TANK 11 TANK 12 TANK 13 TANK 14 TANK 15 TANK 16 > < I30200 OCT 12, 2021 11:50 AM CIRCLE K 2701270 5634 STINE RD. BAKERSFIELD, CA 80749873405001 LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 87 ANNULAR OCT 12, 2021 10:33 AM SENSOR OUT ALARM OCT 12, 2021 9:41 AM FUEL ALARM OCT 12, 2021 9:40 AM FUEL ALARM 2 87 TURBINE OCT 12, 2021 10:33 AM SENSOR OUT ALARM OCT 12, 2021 9:39 AM FUEL ALARM DEC 16, 2020 10:37 AM SENSOR OUT ALARM 3 91 ANNULAR OCT 12, 2021 10:33 AM SENSOR OUT ALARM OCT 12, 2021 9:35 AM FUEL ALARM OCT 12, 2021 9:35 AM FUEL ALARM 4 91 TURBINE OCT 12, 2021 10:33 AM SENSOR OUT ALARM OCT 12, 2021 9:33 AM FUEL ALARM DEC 16, 2020 10:37 AM SENSOR OUT ALARM > < I38200 OCT 12, 2021 11:50 AM > < I90200 OCT 12, 2021 11:50 AM SOFTWARE REVISION LEVEL VERSION 335.00 SOFTWARE# 346335-100-A CREATED - 18.08.27.10.22 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD/APM > < I31600 OCT 12, 2021 11:50 AM CIRCLE K 2701270 5634 STINE RD. BAKERSFIELD, CA 80749873405001 SMART SENSOR ALARM HISTORY REPORT SENSOR LOCATION 1 DISP 1-2 AFM 2 DISP 3-4 AFM MAY 9, 2019 11:52 AM COMMUNICATION ALARM 3 DISP 5-6 AFM 4 DISP 7-8 AFM 5 DISP 1-2 VPS > < I32300 OCT 12, 2021 11:50 AM > < I34200 OCT 12, 2021 11:50 AM > < I34700 OCT 12, 2021 11:50 AM > < I20700 OCT 12, 2021 11:50 AM CIRCLE K 2701270 5634 STINE RD. BAKERSFIELD, CA 80749873405001 TANK LEAK TEST HISTORY T 1:UNL-REG(005) LAST GROSS TEST PASSED: NO TEST PASSED LAST ANNUAL TEST PASSED: NO TEST PASSED FULLEST ANNUAL TEST PASS NO TEST PASSED LAST PERIODIC TEST PASS: NO TEST PASSED FULLEST PERIODIC TEST PASSED EACH MONTH: TEST START TIME HOURS VOLUME % VOLUME TEST TYPE TANK LEAK TEST HISTORY T 2:UNL-PREM LAST GROSS TEST PASSED: NO TEST PASSED LAST ANNUAL TEST PASSED: NO TEST PASSED FULLEST ANNUAL TEST PASS NO TEST PASSED LAST PERIODIC TEST PASS: NO TEST PASSED FULLEST PERIODIC TEST PASSED EACH MONTH: TEST START TIME HOURS VOLUME % VOLUME TEST TYPE > < I31200 OCT 12, 2021 11:50 AM > < I38700 OCT 12, 2021 11:50 AM > < I20300 OCT 12, 2021 11:50 AM CIRCLE K 2701270 5634 STINE RD. BAKERSFIELD, CA 80749873405001 TANK 1 UNL-REG(005) TEST STATUS: OFF LEAK DATA NOT AVAILABLE ON THIS TANK TANK 2 UNL-PREM TEST STATUS: OFF LEAK DATA NOT AVAILABLE ON THIS TANK > < I25100 OCT 12, 2021 11:50 AM CIRCLE K 2701270 5634 STINE RD. BAKERSFIELD, CA 80749873405001 CSLD TEST RESULTS TANK PRODUCT RESULT > < I21300 OCT 12, 2021 11:50 AM CIRCLE K 2701270 5634 STINE RD. BAKERSFIELD, CA 80749873405001 DELIVERY REPORT T 1:UNL-REG(005) INCREASE DATE / TIME GALLONS TC GALLONS WATER TEMP DEG F HEIGHT T 2:UNL-PREM INCREASE DATE / TIME GALLONS TC GALLONS WATER TEMP DEG F HEIGHT > < I31800 OCT 12, 2021 11:51 AM > < I37400 OCT 12, 2021 11:51 AM > < I38900 OCT 12, 2021 11:51 AM > < I11100 OCT 12, 2021 11:51 AM CIRCLE K 2701270 5634 STINE RD. BAKERSFIELD, CA 80749873405001 PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME L 1 ANNULAR 87 ANNULAR SENSOR OUT ALARM CLEAR 10-12-21 10:33AM L 4 STP SUMP 91 TURBINE SENSOR OUT ALARM CLEAR 10-12-21 10:33AM L 3 ANNULAR 91 ANNULAR SENSOR OUT ALARM CLEAR 10-12-21 10:33AM L 2 STP SUMP 87 TURBINE SENSOR OUT ALARM CLEAR 10-12-21 10:33AM L 4 STP SUMP 91 TURBINE SENSOR OUT ALARM ALARM 10-12-21 10:33AM L 3 ANNULAR 91 ANNULAR SENSOR OUT ALARM ALARM 10-12-21 10:33AM L 2 STP SUMP 87 TURBINE SENSOR OUT ALARM ALARM 10-12-21 10:33AM L 1 ANNULAR 87 ANNULAR SENSOR OUT ALARM ALARM 10-12-21 10:33AM L 1 ANNULAR 87 ANNULAR FUEL ALARM CLEAR 10-12-21 9:41AM L 1 ANNULAR 87 ANNULAR FUEL ALARM ALARM 10-12-21 9:41AM L 1 ANNULAR 87 ANNULAR FUEL ALARM CLEAR 10-12-21 9:40AM L 1 ANNULAR 87 ANNULAR FUEL ALARM ALARM 10-12-21 9:40AM L 1 ANNULAR 87 ANNULAR FUEL ALARM CLEAR 10-12-21 9:40AM L 1 ANNULAR 87 ANNULAR FUEL ALARM ALARM 10-12-21 9:40AM L 2 STP SUMP 87 TURBINE FUEL ALARM CLEAR 10-12-21 9:39AM L 2 STP SUMP 87 TURBINE FUEL ALARM ALARM 10-12-21 9:39AM L 3 ANNULAR 91 ANNULAR FUEL ALARM CLEAR 10-12-21 9:35AM L 3 ANNULAR 91 ANNULAR FUEL ALARM ALARM 10-12-21 9:35AM L 3 ANNULAR 91 ANNULAR FUEL ALARM CLEAR 10-12-21 9:35AM L 3 ANNULAR 91 ANNULAR FUEL ALARM ALARM 10-12-21 9:35AM L 4 STP SUMP 91 TURBINE FUEL ALARM CLEAR 10-12-21 9:33AM L 4 STP SUMP 91 TURBINE FUEL ALARM ALARM 10-12-21 9:33AM E 1 OTHER G COMMUNICATION ALARM CLEAR 10-04-21 12:25PM E 1 OTHER G COMMUNICATION ALARM ALARM 10-04-21 12:23PM T 1 TANK UNL-REG(005) LOW PRODUCT ALARM CLEAR 3-17-21 3:01PM T 1 TANK UNL-REG(005) LOW PRODUCT ALARM ALARM 3-17-21 1:25PM T 1 TANK UNL-REG(005) LOW PRODUCT ALARM CLEAR 3-09-21 12:46PM T 1 TANK UNL-REG(005) LOW PRODUCT ALARM ALARM 3-08-21 4:50PM T 1 TANK UNL-REG(005) LOW PRODUCT ALARM CLEAR 3-07-21 4:47AM T 1 TANK UNL-REG(005) LOW PRODUCT ALARM ALARM 3-06-21 10:38PM E 1 OTHER G COMMUNICATION ALARM CLEAR 1-12-21 11:56PM E 1 OTHER G COMMUNICATION ALARM ALARM 1-12-21 9:06PM OTHER ISD GROSS PRES FAIL CLEAR 12-17-20 11:23AM OTHER ISD GROSS PRES FAIL ALARM 12-17-20 9:03AM L 4 STP SUMP 91 TURBINE SENSOR OUT ALARM CLEAR 12-16-20 10:38AM L 3 ANNULAR 91 ANNULAR SENSOR OUT ALARM CLEAR 12-16-20 10:38AM L 2 STP SUMP 87 TURBINE SENSOR OUT ALARM CLEAR 12-16-20 10:38AM L 1 ANNULAR 87 ANNULAR SENSOR OUT ALARM CLEAR 12-16-20 10:38AM L 4 STP SUMP 91 TURBINE SENSOR OUT ALARM ALARM 12-16-20 10:37AM L 3 ANNULAR 91 ANNULAR SENSOR OUT ALARM ALARM 12-16-20 10:37AM L 2 STP SUMP 87 TURBINE SENSOR OUT ALARM ALARM 12-16-20 10:37AM L 1 ANNULAR 87 ANNULAR SENSOR OUT ALARM ALARM 12-16-20 10:37AM L 1 ANNULAR 87 ANNULAR FUEL ALARM CLEAR 12-16-20 10:22AM L 1 ANNULAR 87 ANNULAR FUEL ALARM ALARM 12-16-20 10:22AM L 1 ANNULAR 87 ANNULAR FUEL ALARM CLEAR 12-16-20 10:22AM L 1 ANNULAR 87 ANNULAR FUEL ALARM ALARM 12-16-20 10:22AM L 2 STP SUMP 87 TURBINE FUEL ALARM CLEAR 12-16-20 10:21AM L 2 STP SUMP 87 TURBINE FUEL ALARM ALARM 12-16-20 10:20AM L 3 ANNULAR 91 ANNULAR FUEL ALARM CLEAR 12-16-20 10:17AM L 3 ANNULAR 91 ANNULAR FUEL ALARM ALARM 12-16-20 10:16AM > < I11200 OCT 12, 2021 11:51 AM CIRCLE K 2701270 5634 STINE RD. BAKERSFIELD, CA 80749873405001 NON-PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME h 5 OTHER FP5: BLEND3 DEGRD COLLECT WARN CLEAR 10-11-21 9:00AM h 5 OTHER FP5: BLEND3 DEGRD COLLECT WARN ALARM 10-09-21 9:04AM h 5 OTHER FP5: BLEND3 DEGRD COLLECT WARN CLEAR 10-04-21 12:03PM h 5 OTHER FP5: BLEND3 DEGRD COLLECT WARN ALARM 10-02-21 9:06AM h 3 OTHER FP3: BLEND3 DEGRD COLLECT WARN CLEAR 9-23-21 10:32AM SYSTEM PRINTER ERROR CLEAR 9-23-21 10:31AM SYSTEM PAPER OUT CLEAR 9-23-21 10:31AM SYSTEM PRINTER ERROR ALARM 9-23-21 10:31AM SYSTEM PAPER OUT ALARM 9-23-21 10:31AM SYSTEM PRINTER ERROR CLEAR 9-23-21 10:30AM SYSTEM PAPER OUT CLEAR 9-23-21 10:30AM SYSTEM PRINTER ERROR ALARM 9-23-21 10:28AM SYSTEM PAPER OUT ALARM 9-23-21 10:28AM h 3 OTHER FP3: BLEND3 DEGRD COLLECT WARN ALARM 9-22-21 9:04AM h 3 OTHER FP3: BLEND3 DEGRD COLLECT WARN CLEAR 9-21-21 9:00AM h 8 OTHER FP8: BLEND3 DEGRD COLLECT WARN CLEAR 9-19-21 9:00AM h 8 OTHER FP8: BLEND3 DEGRD COLLECT WARN ALARM 9-18-21 9:04AM h 3 OTHER FP3: BLEND3 DEGRD COLLECT WARN ALARM 9-18-21 9:04AM h 5 OTHER FP5: BLEND3 DEGRD COLLECT WARN CLEAR 9-18-21 9:00AM h 5 OTHER FP5: BLEND3 DEGRD COLLECT WARN ALARM 9-17-21 9:04AM h 3 OTHER FP3: BLEND3 DEGRD COLLECT WARN CLEAR 9-13-21 9:51AM h 3 OTHER FP3: BLEND3 DEGRD COLLECT WARN ALARM 9-13-21 9:04AM h 3 OTHER FP3: BLEND3 DEGRD COLLECT WARN CLEAR 9-12-21 9:00AM h 3 OTHER FP3: BLEND3 DEGRD COLLECT WARN ALARM 9-11-21 9:04AM h 6 OTHER FP6: BLEND3 DEGRD COLLECT WARN CLEAR 9-08-21 11:44AM h 6 OTHER FP6: BLEND3 DEGRD COLLECT WARN ALARM 9-05-21 9:04AM h 5 OTHER FP5: BLEND3 DEGRD COLLECT WARN CLEAR 9-02-21 9:00AM h 5 OTHER FP5: BLEND3 DEGRD COLLECT WARN ALARM 8-31-21 9:05AM h 3 OTHER FP3: BLEND3 DEGRD COLLECT WARN CLEAR 8-16-21 8:54AM h 3 OTHER FP3: BLEND3 DEGRD COLLECT WARN ALARM 8-13-21 9:05AM OTHER ISD VAPOR LEAK WARN CLEAR 7-06-21 8:55AM OTHER ISD VAPOR LEAK WARN ALARM 7-05-21 9:05AM OTHER ISD VAPOR LEAK WARN CLEAR 6-16-21 10:58AM OTHER ISD VAPOR LEAK WARN ALARM 6-12-21 9:04AM OTHER ISD VAPOR LEAK WARN CLEAR 5-31-21 9:04AM OTHER ISD VAPOR LEAK WARN ALARM 5-26-21 9:03AM h 8 OTHER FP8: BLEND3 DEGRD COLLECT WARN CLEAR 5-20-21 10:18AM OTHER ISD VAPOR LEAK WARN CLEAR 5-20-21 10:18AM h 8 OTHER FP8: BLEND3 DEGRD COLLECT WARN ALARM 5-20-21 9:05AM OTHER ISD VAPOR LEAK WARN ALARM 5-19-21 9:05AM SYSTEM PRINTER ERROR CLEAR 5-06-21 11:46AM SYSTEM PAPER OUT CLEAR 5-06-21 11:46AM SYSTEM PAPER OUT ALARM 5-06-21 11:45AM SYSTEM PRINTER ERROR ALARM 5-06-21 11:45AM SYSTEM PRINTER ERROR CLEAR 5-06-21 11:45AM SYSTEM PAPER OUT CLEAR 5-06-21 11:45AM SYSTEM PAPER OUT ALARM 5-06-21 11:44AM SYSTEM PRINTER ERROR ALARM 5-06-21 11:44AM SYSTEM PRINTER ERROR CLEAR 5-06-21 11:24AM SYSTEM PAPER OUT CLEAR 5-06-21 11:24AM > < I11400 OCT 12, 2021 11:51 AM CIRCLE K 2701270 5634 STINE RD. BAKERSFIELD, CA 80749873405001 CLEARED ALARMS REPORT ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME L 1 ANNULAR 87 ANNULAR SENSOR OUT ALARM CLEAR 10-12-21 10:33AM L 4 STP SUMP 91 TURBINE SENSOR OUT ALARM CLEAR 10-12-21 10:33AM L 3 ANNULAR 91 ANNULAR SENSOR OUT ALARM CLEAR 10-12-21 10:33AM L 2 STP SUMP 87 TURBINE SENSOR OUT ALARM CLEAR 10-12-21 10:33AM L 1 ANNULAR 87 ANNULAR FUEL ALARM CLEAR 10-12-21 9:41AM L 1 ANNULAR 87 ANNULAR FUEL ALARM CLEAR 10-12-21 9:40AM L 1 ANNULAR 87 ANNULAR FUEL ALARM CLEAR 10-12-21 9:40AM L 2 STP SUMP 87 TURBINE FUEL ALARM CLEAR 10-12-21 9:39AM L 3 ANNULAR 91 ANNULAR FUEL ALARM CLEAR 10-12-21 9:35AM L 3 ANNULAR 91 ANNULAR FUEL ALARM CLEAR 10-12-21 9:35AM L 4 STP SUMP 91 TURBINE FUEL ALARM CLEAR 10-12-21 9:33AM E 1 OTHER G COMMUNICATION ALARM CLEAR 10-04-21 12:25PM T 1 TANK UNL-REG(005) LOW PRODUCT ALARM CLEAR 3-17-21 3:01PM T 1 TANK UNL-REG(005) LOW PRODUCT ALARM CLEAR 3-09-21 12:46PM T 1 TANK UNL-REG(005) LOW PRODUCT ALARM CLEAR 3-07-21 4:47AM E 1 OTHER G COMMUNICATION ALARM CLEAR 1-12-21 11:56PM OTHER ISD GROSS PRES FAIL CLEAR 12-17-20 11:23AM L 4 STP SUMP 91 TURBINE SENSOR OUT ALARM CLEAR 12-16-20 10:38AM L 3 ANNULAR 91 ANNULAR SENSOR OUT ALARM CLEAR 12-16-20 10:38AM L 2 STP SUMP 87 TURBINE SENSOR OUT ALARM CLEAR 12-16-20 10:38AM L 1 ANNULAR 87 ANNULAR SENSOR OUT ALARM CLEAR 12-16-20 10:38AM L 1 ANNULAR 87 ANNULAR FUEL ALARM CLEAR 12-16-20 10:22AM L 1 ANNULAR 87 ANNULAR FUEL ALARM CLEAR 12-16-20 10:22AM L 2 STP SUMP 87 TURBINE FUEL ALARM CLEAR 12-16-20 10:21AM L 3 ANNULAR 91 ANNULAR FUEL ALARM CLEAR 12-16-20 10:17AM h 5 OTHER FP5: BLEND3 DEGRD COLLECT WARN CLEAR 10-11-21 9:00AM h 5 OTHER FP5: BLEND3 DEGRD COLLECT WARN CLEAR 10-04-21 12:03PM h 3 OTHER FP3: BLEND3 DEGRD COLLECT WARN CLEAR 9-23-21 10:32AM SYSTEM PRINTER ERROR CLEAR 9-23-21 10:31AM SYSTEM PAPER OUT CLEAR 9-23-21 10:31AM SYSTEM PRINTER ERROR CLEAR 9-23-21 10:30AM SYSTEM PAPER OUT CLEAR 9-23-21 10:30AM h 3 OTHER FP3: BLEND3 DEGRD COLLECT WARN CLEAR 9-21-21 9:00AM h 8 OTHER FP8: BLEND3 DEGRD COLLECT WARN CLEAR 9-19-21 9:00AM h 5 OTHER FP5: BLEND3 DEGRD COLLECT WARN CLEAR 9-18-21 9:00AM h 3 OTHER FP3: BLEND3 DEGRD COLLECT WARN CLEAR 9-13-21 9:51AM h 3 OTHER FP3: BLEND3 DEGRD COLLECT WARN CLEAR 9-12-21 9:00AM h 6 OTHER FP6: BLEND3 DEGRD COLLECT WARN CLEAR 9-08-21 11:44AM h 5 OTHER FP5: BLEND3 DEGRD COLLECT WARN CLEAR 9-02-21 9:00AM h 3 OTHER FP3: BLEND3 DEGRD COLLECT WARN CLEAR 8-16-21 8:54AM OTHER ISD VAPOR LEAK WARN CLEAR 7-06-21 8:55AM OTHER ISD VAPOR LEAK WARN CLEAR 6-16-21 10:58AM OTHER ISD VAPOR LEAK WARN CLEAR 5-31-21 9:04AM h 8 OTHER FP8: BLEND3 DEGRD COLLECT WARN CLEAR 5-20-21 10:18AM OTHER ISD VAPOR LEAK WARN CLEAR 5-20-21 10:18AM SYSTEM PRINTER ERROR CLEAR 5-06-21 11:46AM SYSTEM PAPER OUT CLEAR 5-06-21 11:46AM SYSTEM PRINTER ERROR CLEAR 5-06-21 11:45AM SYSTEM PAPER OUT CLEAR 5-06-21 11:45AM SYSTEM PRINTER ERROR CLEAR 5-06-21 11:24AM SYSTEM PAPER OUT CLEAR 5-06-21 11:24AM > < I40200 OCT 12, 2021 11:51 AM > < I72300 OCT 12, 2021 11:51 AM CIRCLE K 2701270 5634 STINE RD. BAKERSFIELD, CA 80749873405001 SMARTSENSOR ASSIGNMENT DEVICE LABEL CATEGORY 01 DISP 1-2 AFM AIR FLOW METER 02 DISP 3-4 AFM AIR FLOW METER 03 DISP 5-6 AFM AIR FLOW METER 04 DISP 7-8 AFM AIR FLOW METER 05 DISP 1-2 VPS VAPOR PRESSURE 06 UNKNOWN 07 UNKNOWN 08 UNKNOWN 09 UNKNOWN 10 UNKNOWN 11 UNKNOWN 12 UNKNOWN 13 UNKNOWN 14 UNKNOWN 15 UNKNOWN 16 UNKNOWN 17 UNKNOWN 18 UNKNOWN 19 UNKNOWN 20 UNKNOWN 21 UNKNOWN 22 UNKNOWN 23 UNKNOWN 24 UNKNOWN 25 UNKNOWN 26 UNKNOWN 27 UNKNOWN 28 UNKNOWN 29 UNKNOWN 30 UNKNOWN 31 UNKNOWN 32 UNKNOWN 33 UNKNOWN 34 UNKNOWN 35 UNKNOWN 36 UNKNOWN 37 UNKNOWN 38 UNKNOWN 39 UNKNOWN 40 UNKNOWN > < I10200 OCT 12, 2021 11:51 AM CIRCLE K 2701270 5634 STINE RD. BAKERSFIELD, CA 80749873405001 SYSTEM CONFIGURATION SLOT BOARD TYPE POWER ON RESET CURRENT 1 UNUSED 9605455 9419555 2 UNUSED 9571668 9402406 3 UNUSED 9568164 9387980 4 UNUSED 9566989 9391200 5 UNUSED 9562784 9395946 6 8SMARTSENSOR BD 39377 39359 7 INTERSTITIAL BD 201213 201410 8 4 PROBE / G.T. 162505 162737 9 RELAY BOARD 14938 14952 10 UNUSED 9577555 9395214 11 UNUSED 9570649 9399651 12 UNUSED 9561724 9392841 13 UNUSED 9566712 9391025 14 UNUSED 9562486 9394409 15 UNUSED 9560961 9382295 16 UNUSED 9562424 9394182 COMM 1 ELEC DISP INT. 100729 100900 COMM 2 RS232 SERIAL BD 15000 15035 COMM 3 RS232 SERIAL BD 15021 15055 COMM 4 UNUSED 9572072 9394863 COMM 5 SERIAL SAT BD 9563970 478346 COMM 6 UNUSED 9556817 9391520 > < I31600 OCT 12, 2021 11:51 AM CIRCLE K 2701270 5634 STINE RD. BAKERSFIELD, CA 80749873405001 SMART SENSOR ALARM HISTORY REPORT SENSOR LOCATION 1 DISP 1-2 AFM 2 DISP 3-4 AFM MAY 9, 2019 11:52 AM COMMUNICATION ALARM 3 DISP 5-6 AFM 4 DISP 7-8 AFM 5 DISP 1-2 VPS >