Loading...
HomeMy WebLinkAbout2021-10-08-2708606-MC Appendix VI Underground Storage Tank Monitoring System Certification Form CERS = California Environmental Reporting System, GPH = Gallons Per Hour, ID = Identification, ICC = International Code Council, LLD = Line Leak Detector, NA = Not Applicable, SW = Single-Walled, UDC = Under-Dispenser Containment, UST = Underground Storage Tank, VPH = Vacuum/Pressure/Hydrostatic Page 1 of 6 TYPE OF ACTION ☐ Installation ☐ Repair ☒ 12 Month 1. FACILITY INFORMATION CERS ID 10023799 Certification Date 10/8/2021 Facility Name Circle k Facility Address 1030 Oak st City Bakersfield ZIP Code 93304 2. SERVICE TECHNICIAN INFORMATION Company Performing the Certification B&T Service Station Contractors Phone 805-929-8944 Mailing Address 630 S. Frontage rd Nipomo Service Technician Performing Test Rick Binger Contractor/Tank Tester License Number 902034 ICC Number 8452629 ICC Expiration Date 3/31/2023 3. TRAINING AND CERTIFICATIONS Manufacturer and Test Equipment Training Certifications Expiration Date Veeder Root B47631 05/09/2023 Redjacket B47631 02/07/2023 VMI 3950 11/16/2022 4. CERTIFICATION BY SERVICE TECHNICIAN CONDUCTING TEST I hereby certify that the monitoring system is operational in accordance with California Code of Regulations, title 23, division 3, chapter 16, section 2638; that required supporting documentation is attached; and all information contained herein is accurate. Service Technician Signature Date 10/8/2021 Total # of Pages Underground Storage Tank Monitoring System Certification Form Page 2 of 6 5. MONITORING SYSTEM AND PROGRAMMING A separate Monitoring System Certification Form must be prepared for each control panel. Make of Monitoring System Control Panel Veeder Root Model of Monitoring System Control Panel TLS-350 Software Version Installed 334.01 Attach the post-certification reports if the monitoring system is capable of generating either; ☒Monitoring System Set-up ☒ Alarm History Report Yes No NA All monitoring equipment is operational per manufacturer’s specifications? ☒ ☐ Secondary containment systems are free of damage, debris, or liquid? ☒ ☐ Are the audible and visual alarms operational? ☒ ☐ All sensors have been: 1) visually inspected for wiring kinks, breaks and residual buildup on floats; and 2) tested for functionality and confirmed operational? ☒ ☐ ☐ Are all sensors installed to detect a release at the earliest opportunity in the secondary containment? ☒ ☐ ☐ The monitoring system set-up was reviewed, and proper settings confirmed? ☒ ☐ ☐ Was the monitoring control panel’s backup battery visually inspected, functionally tested, and confirmed operational? ☒ ☐ ☐ Does the flow of fuel stop at the dispenser if a release is detected in the under-dispenser containment? ☒ ☐ ☐ Does the turbine automatically shut down if the piping secondary containment monitoring system fails to operate or is electrically disconnected? ☒ ☐ ☐ Does the turbine automatically shut down if the piping secondary containment monitoring system detects a release? Which sensors initiate positive shut down? (Check all that apply) ☒ Sump ☐ UDC ☒ ☐ ☐ If monitoring system alarms are relayed to a remote monitoring center, is all communication equipment operational? ☒ ☐ ☐ Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 Underground Storage Tank Monitoring System Certification Form Page 3 of 6 6. SENSOR TESTING RESULTS List only sensors tested on date of this certification. List “Sensor ID” as labeled in system programming. Additional copies of this page may be attached to accommodate all sensors tested. Sensor ID Sensor Model Component(s) Monitored Pass Fail L1 794390-409 87 Annular ☒ ☐ L2 794390-409 91 Annular ☒ ☐ L3 794390-409 89 Annular ☒ ☐ L7 794380-208 87 Fill ☒ ☐ L8 794380-208 91 Fill ☒ ☐ L9 794380-208 89 Fill ☒ ☐ S1 857080-102 87 Turbine ☒ ☐ S2 857080-102 91 Turbine ☒ ☐ S3 857080-102 89 Turbine ☒ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 Underground Storage Tank Monitoring System Certification Form Page 4 of 6 7. LINE LEAK DETECTOR TESTING ☐ Check this box if line leak detectors ARE NOT installed. (Do not complete this section.) Simulated release rate verified: (Check all that apply.) ☒ 3 GPH ☐ 0.1 GPH ☐ 0.2 GPH Yes No NA Has the testing apparatus been properly calibrated? ☒ ☐ ☐ For emergency generator tank systems, does the LLD create an audible and visual alarm when a leak is detected? ☐ ☐ ☒ For mechanical LLDs, does the LLD restrict the flow through the pipe when a release is detected? ☒ ☐ ☐ For electronic LLDs, does the turbine automatically shut off when a release is detected? ☐ ☐ ☒ For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system is disabled or disconnected? ☐ ☐ ☒ For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system malfunctions or fails a tightness test? ☐ ☐ ☒ For electronic LLDs, have all accessible wiring connections been visually inspected for kinks and breaks? ☐ ☐ ☒ Were all items on the equipment manufacturer’s maintenance checklist completed? ☒ ☐ ☐ Were all LLDs confirmed operational within regulatory requirements? ☒ ☐ ☐ LLD ID LLD Model Lines Monitored Pass Fail Tank 1 VMI LD2000 87 ☒ ☐ Tank 2 VMI LD2000 89 ☒ ☐ Tank 3 VMI LD2000 91 ☒ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 Underground Storage Tank Monitoring System Certification Form Page 5 of 6 8. IN-TANK GAUGING TESTING ☐ Check this box if tank gauging is used only for inventory control. ☒ Check this box if NO tank gauging equipment is installed. (Do not complete this section if either box is checked.) Yes No NA All wiring has been: 1) visually inspected for kinks, breaks and proper entry and termination; and 2) tested for ground faults? ☐ ☐ ☐ Were all in-tank gauging probes visually inspected for damage and residue buildup to ensure that floats move freely, functionally tested, and confirmed operational? ☐ ☐ ☐ Was accuracy of system’s product level readings tested? ☐ ☐ ☐ Was accuracy of system’s water level readings tested? ☐ ☐ ☐ Were all probes reinstalled properly? ☐ ☐ ☐ Were all items on the equipment manufacturer’s maintenance checklist completed? ☐ ☐ ☐ Probe ID Probe Model Tanks Monitored Pass Fail ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ ☐ 9. COMMENTS Describe all answers marked “No” or “Fail” and proposed remedy. List all monitoring equipment either replaced or repaired. Underground Storage Tank Monitoring System Certification Form Page 6 of 6 10. MONITORING SITE PLAN Date site plan was prepared: If a site plan has been prepared that shows all required information, you may include it, rather than this page, with your Monitoring System Certification Form. The site plan must show the general layout of tanks and identify locations of the monitoring panel, and all leak detection equipment and monitoring locations. Include a legend for all symbols depicted. < I10100 OCT 8, 2021 10:53 AM CIRCLE K 2708606 1030 OAK ST 661-861-8048 BAKERSFIELD,CA.93304 SYSTEM STATUS REPORT ALL FUNCTIONS NORMAL > < I51700 OCT 8, 2021 10:53 AM SYSTEM TYPE AND LANGUAGE FLAG SYSTEM UNITS U.S. SYSTEM LANGUAGE ENGLISH SYSTEM DATE/TIME FORMAT MON DD YYYY HH:MM:SS xM > < I50F00 OCT 8, 2021 10:53 AM MON DD YYYY HH:MM:SS xM > < I60100 OCT 8, 2021 10:53 AM TANK CONFIGURATION DEVICE LABEL CONFIGURED 1 UNL Regular ON 2 UNL Premium ON 3 UNL Plus NoBlend ON 4 OFF > < I60200 OCT 8, 2021 10:53 AM TANK PRODUCT LABEL TANK PRODUCT LABEL 1 UNL Regular 2 UNL Premium 3 UNL Plus NoBlend 4 > < I60300 OCT 8, 2021 10:53 AM TANK PRODUCT CODE TANK PRODUCT LABEL 1 UNL Regular A 2 UNL Premium C 3 UNL Plus NoBlend B 4 4 > < I60400 OCT 8, 2021 10:54 AM TANK FULL VOLUME TANK PRODUCT LABEL GALLONS 1 UNL Regular 9696 2 UNL Premium 9696 3 UNL Plus NoBlend 9696 4 0 > < I60700 OCT 8, 2021 10:54 AM TANK DIAMETER TANK PRODUCT LABEL INCHES 1 UNL Regular 91.75 2 UNL Premium 91.75 3 UNL Plus NoBlend 91.75 4 0.00 > < I60900 OCT 8, 2021 10:54 AM TANK THERMAL COEFFICIENT TANK PRODUCT LABEL 1 UNL Regular 0.000700 2 UNL Premium 0.000700 3 UNL Plus NoBlend 0.000700 4 0.000000 > < I61200 OCT 8, 2021 10:54 AM TANK MANIFOLDED PARTNERS TANK PRODUCT LABEL SIPHON MANIFOLDED TANKS LINE MANIFOLDED TANKS 1 UNL Regular NONE NONE 2 UNL Premium NONE NONE 3 UNL Plus NoBlend NONE NONE 4 NONE NONE > < I62100 OCT 8, 2021 10:54 AM TANK LOW PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 UNL Regular 1000 2 UNL Premium 1000 3 UNL Plus NoBlend 490 4 0 > < I62200 OCT 8, 2021 10:54 AM TANK HIGH PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 UNL Regular 9211 2 UNL Premium 9211 3 UNL Plus NoBlend 9211 4 0 > < I62300 OCT 8, 2021 10:54 AM TANK OVERFILL LEVEL LIMIT TANK PRODUCT LABEL GALLONS 1 UNL Regular 8726 2 UNL Premium 8726 3 UNL Plus NoBlend 8726 4 0 > < I62400 OCT 8, 2021 10:54 AM TANK HIGH WATER LEVEL LIMIT TANK PRODUCT LABEL INCHES 1 UNL Regular 3.0 2 UNL Premium 3.0 3 UNL Plus NoBlend 3.0 > < I62800 OCT 8, 2021 10:55 AM TANK MAXIMUM VOLUME LIMIT TANK PRODUCT LABEL GALLONS 1 UNL Regular 9696 2 UNL Premium 9696 3 UNL Plus NoBlend 9696 4 0 > < I62900 OCT 8, 2021 10:55 AM TANK DELIVERY REQUIRED LIMIT TANK PRODUCT LABEL GALLONS 1 UNL Regular 491 2 UNL Premium 491 3 UNL Plus NoBlend 491 4 0 > < I70300 OCT 8, 2021 10:55 AM LIQUID TYPE SENSOR LOCATION TYPE 1 87 ANNULAR TRI-STATE (SINGLE FLOAT) 2 91 ANNULAR TRI-STATE (SINGLE FLOAT) 3 89 ANNULAR TRI-STATE (SINGLE FLOAT) 4 TRI-STATE (SINGLE FLOAT) 5 TRI-STATE (SINGLE FLOAT) 6 TRI-STATE (SINGLE FLOAT) 7 87 FILL TRI-STATE (SINGLE FLOAT) 8 91 FILL TRI-STATE (SINGLE FLOAT) 9 89 FILL TRI-STATE (SINGLE FLOAT) 10 TRI-STATE (SINGLE FLOAT) 11 TRI-STATE (SINGLE FLOAT) 12 TRI-STATE (SINGLE FLOAT) 13 TRI-STATE (SINGLE FLOAT) 14 TRI-STATE (SINGLE FLOAT) 15 TRI-STATE (SINGLE FLOAT) 16 TRI-STATE (SINGLE FLOAT) > < I20600 OCT 8, 2021 10:55 AM CIRCLE K 2708606 1030 OAK ST 661-861-8048 BAKERSFIELD,CA.93304 TANK ALARM HISTORY TANK 1 UNL Regular OVERFILL ALARM JUL 24, 2021 11:59 PM FEB 7, 2021 1:38 PM MAY 29, 2020 12:32 AM LOW PRODUCT ALARM MAY 14, 2020 12:44 PM HIGH PRODUCT ALARM MAY 14, 2020 12:44 PM PROBE OUT MAY 14, 2020 12:45 PM MAY 14, 2020 12:41 PM TANK 2 UNL Premium OVERFILL ALARM MAY 14, 2020 12:33 PM LOW PRODUCT ALARM MAR 17, 2021 10:44 AM MAR 2, 2021 11:35 AM JAN 26, 2021 12:01 PM HIGH PRODUCT ALARM MAY 14, 2020 12:34 PM INVALID FUEL LEVEL MAR 17, 2021 11:00 AM MAR 2, 2021 11:35 AM JAN 26, 2021 12:02 PM PROBE OUT MAR 17, 2021 10:56 AM MAR 17, 2021 10:44 AM MAR 2, 2021 11:52 AM DELIVERY NEEDED MAR 17, 2021 10:44 AM MAR 2, 2021 11:35 AM JAN 26, 2021 12:02 PM LOW TEMP WARNING JAN 26, 2021 12:25 PM JAN 26, 2021 12:03 PM TANK 3 UNL Plus NoBlend OVERFILL ALARM MAY 14, 2020 12:39 PM HIGH PRODUCT ALARM MAY 14, 2020 12:39 PM PROBE OUT MAY 14, 2020 12:40 PM MAY 14, 2020 12:36 PM TANK 5 TANK 6 TANK 7 TANK 8 TANK 9 TANK 10 TANK 11 TANK 12 TANK 13 TANK 14 TANK 15 TANK 16 > < I30200 OCT 8, 2021 10:56 AM CIRCLE K 2708606 1030 OAK ST 661-861-8048 BAKERSFIELD,CA.93304 LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 87 ANNULAR OCT 8, 2021 10:07 AM SENSOR OUT ALARM OCT 8, 2021 9:58 AM FUEL ALARM OCT 8, 2021 9:40 AM FUEL ALARM 2 91 ANNULAR OCT 8, 2021 10:07 AM SENSOR OUT ALARM OCT 8, 2021 9:50 AM FUEL ALARM OCT 8, 2021 9:32 AM FUEL ALARM 3 89 ANNULAR OCT 8, 2021 10:07 AM SENSOR OUT ALARM OCT 8, 2021 9:54 AM FUEL ALARM OCT 8, 2021 9:37 AM FUEL ALARM 7 87 FILL OCT 8, 2021 10:07 AM SENSOR OUT ALARM OCT 8, 2021 9:58 AM FUEL ALARM SEP 14, 2021 10:16 AM FUEL ALARM 8 91 FILL OCT 8, 2021 10:07 AM SENSOR OUT ALARM OCT 8, 2021 9:50 AM FUEL ALARM NOV 24, 2020 10:40 AM FUEL ALARM 9 89 FILL OCT 8, 2021 9:53 AM FUEL ALARM NOV 24, 2020 10:56 AM SENSOR OUT ALARM NOV 24, 2020 10:26 AM FUEL ALARM > < I38200 OCT 8, 2021 10:56 AM > < I90200 OCT 8, 2021 10:56 AM SOFTWARE REVISION LEVEL VERSION 334.01 SOFTWARE# 346334-100-B CREATED - 17.01.09.16.10 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD/APM > < I31600 OCT 8, 2021 10:56 AM CIRCLE K 2708606 1030 OAK ST 661-861-8048 BAKERSFIELD,CA.93304 SMART SENSOR ALARM HISTORY REPORT SENSOR LOCATION 1 87 TURBINE OCT 8, 2021 9:57 AM INSTALL ALARM OCT 8, 2021 9:56 AM WATER ALARM SEP 14, 2021 10:41 AM INSTALL ALARM 2 91 TURBINE OCT 8, 2021 9:48 AM INSTALL ALARM OCT 8, 2021 9:48 AM WATER ALARM OCT 8, 2021 9:46 AM INSTALL ALARM 3 89 TURBINE OCT 8, 2021 9:52 AM INSTALL ALARM OCT 8, 2021 9:52 AM WATER ALARM OCT 8, 2021 9:52 AM INSTALL ALARM 9 UDC 3-4 10 UDC 1-2 11 UDC 1-2 PRESS SENSOR > < I32300 OCT 8, 2021 10:56 AM > < I34200 OCT 8, 2021 10:56 AM > < I34700 OCT 8, 2021 10:56 AM > < I20700 OCT 8, 2021 10:56 AM CIRCLE K 2708606 1030 OAK ST 661-861-8048 BAKERSFIELD,CA.93304 TANK LEAK TEST HISTORY T 1:UNL Regular LAST GROSS TEST PASSED: NO TEST PASSED LAST ANNUAL TEST PASSED: NO TEST PASSED FULLEST ANNUAL TEST PASS NO TEST PASSED LAST PERIODIC TEST PASS: NO TEST PASSED FULLEST PERIODIC TEST PASSED EACH MONTH: TEST START TIME HOURS VOLUME % VOLUME TEST TYPE TANK LEAK TEST HISTORY T 2:UNL Premium LAST GROSS TEST PASSED: NO TEST PASSED LAST ANNUAL TEST PASSED: NO TEST PASSED FULLEST ANNUAL TEST PASS NO TEST PASSED LAST PERIODIC TEST PASS: NO TEST PASSED FULLEST PERIODIC TEST PASSED EACH MONTH: TEST START TIME HOURS VOLUME % VOLUME TEST TYPE TANK LEAK TEST HISTORY T 3:UNL Plus NoBlend LAST GROSS TEST PASSED: NO TEST PASSED LAST ANNUAL TEST PASSED: NO TEST PASSED FULLEST ANNUAL TEST PASS NO TEST PASSED LAST PERIODIC TEST PASS: NO TEST PASSED FULLEST PERIODIC TEST PASSED EACH MONTH: TEST START TIME HOURS VOLUME % VOLUME TEST TYPE > < I31200 OCT 8, 2021 10:57 AM > < I38700 OCT 8, 2021 10:57 AM > < I20300 OCT 8, 2021 10:57 AM CIRCLE K 2708606 1030 OAK ST 661-861-8048 BAKERSFIELD,CA.93304 TANK 1 UNL Regular TEST STATUS: OFF LEAK DATA NOT AVAILABLE ON THIS TANK TANK 2 UNL Premium TEST STATUS: OFF LEAK DATA NOT AVAILABLE ON THIS TANK TANK 3 UNL Plus NoBlend TEST STATUS: OFF LEAK DATA NOT AVAILABLE ON THIS TANK > < I25100 OCT 8, 2021 10:57 AM CIRCLE K 2708606 1030 OAK ST 661-861-8048 BAKERSFIELD,CA.93304 CSLD TEST RESULTS TANK PRODUCT RESULT > < I21300 OCT 8, 2021 10:57 AM CIRCLE K 2708606 1030 OAK ST 661-861-8048 BAKERSFIELD,CA.93304 DELIVERY REPORT T 1:UNL Regular INCREASE DATE / TIME GALLONS TC GALLONS WATER TEMP DEG F HEIGHT T 2:UNL Premium INCREASE DATE / TIME GALLONS TC GALLONS WATER TEMP DEG F HEIGHT T 3:UNL Plus NoBlend INCREASE DATE / TIME GALLONS TC GALLONS WATER TEMP DEG F HEIGHT > < I31800 OCT 8, 2021 10:57 AM > < I37400 OCT 8, 2021 10:58 AM > < I38900 OCT 8, 2021 10:58 AM > < I11100 OCT 8, 2021 10:58 AM CIRCLE K 2708606 1030 OAK ST 661-861-8048 BAKERSFIELD,CA.93304 PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME L 7 PIPE 87 FILL SENSOR OUT ALARM CLEAR 10-08-21 10:08AM L 3 ANNULAR 89 ANNULAR SENSOR OUT ALARM CLEAR 10-08-21 10:08AM L 2 ANNULAR 91 ANNULAR SENSOR OUT ALARM CLEAR 10-08-21 10:08AM L 8 PIPE 91 FILL SENSOR OUT ALARM CLEAR 10-08-21 10:08AM L 1 ANNULAR 87 ANNULAR SENSOR OUT ALARM CLEAR 10-08-21 10:08AM L 8 PIPE 91 FILL SENSOR OUT ALARM ALARM 10-08-21 10:07AM L 7 PIPE 87 FILL SENSOR OUT ALARM ALARM 10-08-21 10:07AM L 3 ANNULAR 89 ANNULAR SENSOR OUT ALARM ALARM 10-08-21 10:07AM L 2 ANNULAR 91 ANNULAR SENSOR OUT ALARM ALARM 10-08-21 10:07AM L 1 ANNULAR 87 ANNULAR SENSOR OUT ALARM ALARM 10-08-21 10:07AM L 1 ANNULAR 87 ANNULAR FUEL ALARM CLEAR 10-08-21 9:58AM L 1 ANNULAR 87 ANNULAR FUEL ALARM ALARM 10-08-21 9:58AM L 7 PIPE 87 FILL FUEL ALARM CLEAR 10-08-21 9:58AM L 7 PIPE 87 FILL FUEL ALARM ALARM 10-08-21 9:58AM s 1 OTHER 87 TURBINE INSTALL ALARM CLEAR 10-08-21 9:57AM s 1 OTHER 87 TURBINE INSTALL ALARM ALARM 10-08-21 9:57AM s 1 OTHER 87 TURBINE WATER ALARM CLEAR 10-08-21 9:56AM s 1 OTHER 87 TURBINE WATER ALARM ALARM 10-08-21 9:56AM L 3 ANNULAR 89 ANNULAR FUEL ALARM CLEAR 10-08-21 9:54AM L 3 ANNULAR 89 ANNULAR FUEL ALARM ALARM 10-08-21 9:54AM L 9 PIPE 89 FILL FUEL ALARM CLEAR 10-08-21 9:53AM L 9 PIPE 89 FILL FUEL ALARM ALARM 10-08-21 9:53AM s 3 OTHER 89 TURBINE INSTALL ALARM CLEAR 10-08-21 9:53AM s 3 OTHER 89 TURBINE INSTALL ALARM ALARM 10-08-21 9:52AM s 3 OTHER 89 TURBINE WATER ALARM CLEAR 10-08-21 9:52AM s 3 OTHER 89 TURBINE WATER ALARM ALARM 10-08-21 9:52AM s 3 OTHER 89 TURBINE INSTALL ALARM CLEAR 10-08-21 9:52AM s 3 OTHER 89 TURBINE INSTALL ALARM ALARM 10-08-21 9:52AM L 2 ANNULAR 91 ANNULAR FUEL ALARM CLEAR 10-08-21 9:50AM L 2 ANNULAR 91 ANNULAR FUEL ALARM ALARM 10-08-21 9:50AM L 8 PIPE 91 FILL FUEL ALARM CLEAR 10-08-21 9:50AM L 8 PIPE 91 FILL FUEL ALARM ALARM 10-08-21 9:50AM s 2 OTHER 91 TURBINE INSTALL ALARM CLEAR 10-08-21 9:49AM s 2 OTHER 91 TURBINE INSTALL ALARM ALARM 10-08-21 9:48AM s 2 OTHER 91 TURBINE WATER ALARM CLEAR 10-08-21 9:48AM s 2 OTHER 91 TURBINE WATER ALARM ALARM 10-08-21 9:48AM s 2 OTHER 91 TURBINE INSTALL ALARM CLEAR 10-08-21 9:48AM s 2 OTHER 91 TURBINE INSTALL ALARM ALARM 10-08-21 9:46AM L 1 ANNULAR 87 ANNULAR FUEL ALARM CLEAR 10-08-21 9:40AM L 1 ANNULAR 87 ANNULAR FUEL ALARM ALARM 10-08-21 9:40AM L 1 ANNULAR 87 ANNULAR FUEL ALARM CLEAR 10-08-21 9:40AM L 1 ANNULAR 87 ANNULAR FUEL ALARM ALARM 10-08-21 9:39AM L 1 ANNULAR 87 ANNULAR FUEL ALARM CLEAR 10-08-21 9:39AM L 1 ANNULAR 87 ANNULAR FUEL ALARM ALARM 10-08-21 9:39AM L 1 ANNULAR 87 ANNULAR FUEL ALARM CLEAR 10-08-21 9:39AM L 1 ANNULAR 87 ANNULAR FUEL ALARM ALARM 10-08-21 9:39AM L 3 ANNULAR 89 ANNULAR FUEL ALARM CLEAR 10-08-21 9:37AM L 3 ANNULAR 89 ANNULAR FUEL ALARM ALARM 10-08-21 9:37AM L 2 ANNULAR 91 ANNULAR FUEL ALARM CLEAR 10-08-21 9:33AM L 2 ANNULAR 91 ANNULAR FUEL ALARM ALARM 10-08-21 9:32AM > < I11200 OCT 8, 2021 10:58 AM CIRCLE K 2708606 1030 OAK ST 661-861-8048 BAKERSFIELD,CA.93304 NON-PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME SYSTEM PRINTER ERROR CLEAR 9-25-21 5:45AM SYSTEM PAPER OUT CLEAR 9-25-21 5:45AM SYSTEM PAPER OUT ALARM 9-25-21 5:45AM SYSTEM PRINTER ERROR ALARM 9-25-21 5:45AM SYSTEM PRINTER ERROR CLEAR 9-25-21 5:44AM SYSTEM PRINTER ERROR ALARM 9-25-21 5:43AM SYSTEM PRINTER ERROR CLEAR 9-25-21 5:43AM SYSTEM PAPER OUT CLEAR 9-25-21 5:43AM SYSTEM PRINTER ERROR ALARM 9-24-21 5:10PM SYSTEM PAPER OUT ALARM 9-24-21 5:10PM OTHER ISD VAPOR LEAK WARN CLEAR 9-13-21 10:38AM OTHER ISD VAPOR LEAK WARN ALARM 9-07-21 9:06AM OTHER ISD VAPOR LEAK WARN CLEAR 8-27-21 9:29AM OTHER ISD VAPOR LEAK WARN ALARM 8-25-21 9:05AM h 2 OTHER FP2: BLEND3 DEGRD COLLECT WARN CLEAR 8-13-21 9:00AM h 2 OTHER FP2: BLEND3 DEGRD COLLECT WARN ALARM 8-11-21 9:03AM SYSTEM PRINTER ERROR CLEAR 8-10-21 7:32AM SYSTEM PAPER OUT CLEAR 8-10-21 7:32AM SYSTEM PRINTER ERROR ALARM 8-10-21 7:32AM SYSTEM PAPER OUT ALARM 8-10-21 7:32AM SYSTEM PRINTER ERROR CLEAR 8-10-21 7:32AM SYSTEM PAPER OUT CLEAR 8-10-21 7:32AM SYSTEM PRINTER ERROR ALARM 8-10-21 7:31AM SYSTEM PAPER OUT ALARM 8-10-21 7:31AM SYSTEM PRINTER ERROR CLEAR 8-10-21 7:30AM SYSTEM PAPER OUT CLEAR 8-10-21 7:30AM SYSTEM PRINTER ERROR ALARM 8-10-21 7:29AM SYSTEM PAPER OUT ALARM 8-10-21 7:29AM OTHER ISD VAPOR LEAK WARN CLEAR 8-07-21 9:05AM OTHER ISD VAPOR LEAK WARN ALARM 8-06-21 9:05AM OTHER ISD VAPOR LEAK WARN CLEAR 7-29-21 3:05PM OTHER ISD VAPOR LEAK WARN ALARM 7-27-21 9:05AM OTHER ISD VAPOR LEAK WARN CLEAR 7-21-21 12:41PM OTHER ISD VAPOR LEAK WARN ALARM 7-15-21 9:05AM OTHER ISD VAPOR LEAK WARN CLEAR 7-09-21 11:39AM h 4 OTHER FP4: BLEND3 DEGRD COLLECT WARN CLEAR 7-08-21 9:00AM h 4 OTHER FP4: BLEND3 DEGRD COLLECT WARN ALARM 7-07-21 9:05AM SYSTEM PRINTER ERROR CLEAR 7-04-21 7:14AM SYSTEM PAPER OUT CLEAR 7-04-21 7:14AM SYSTEM PRINTER ERROR ALARM 7-03-21 11:43PM SYSTEM PAPER OUT ALARM 7-03-21 11:43PM OTHER ISD VAPOR LEAK WARN ALARM 7-03-21 9:06AM OTHER ISD SENSOR OUT WARN CLEAR 6-30-21 9:05AM OTHER ISD SENSOR OUT WARN ALARM 6-29-21 9:05AM OTHER ISD VAPOR LEAK WARN CLEAR 6-26-21 9:05AM OTHER ISD VAPOR LEAK WARN ALARM 6-24-21 9:06AM OTHER ISD VAPOR LEAK WARN CLEAR 6-21-21 9:06AM OTHER ISD VAPOR LEAK WARN ALARM 6-20-21 9:06AM OTHER ISD VAPOR LEAK WARN CLEAR 6-09-21 9:03AM OTHER ISD VAPOR LEAK WARN ALARM 6-02-21 9:05AM > < I11400 OCT 8, 2021 10:59 AM CIRCLE K 2708606 1030 OAK ST 661-861-8048 BAKERSFIELD,CA.93304 CLEARED ALARMS REPORT ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME L 7 PIPE 87 FILL SENSOR OUT ALARM CLEAR 10-08-21 10:08AM L 3 ANNULAR 89 ANNULAR SENSOR OUT ALARM CLEAR 10-08-21 10:08AM L 2 ANNULAR 91 ANNULAR SENSOR OUT ALARM CLEAR 10-08-21 10:08AM L 8 PIPE 91 FILL SENSOR OUT ALARM CLEAR 10-08-21 10:08AM L 1 ANNULAR 87 ANNULAR SENSOR OUT ALARM CLEAR 10-08-21 10:08AM L 1 ANNULAR 87 ANNULAR FUEL ALARM CLEAR 10-08-21 9:58AM L 7 PIPE 87 FILL FUEL ALARM CLEAR 10-08-21 9:58AM s 1 OTHER 87 TURBINE INSTALL ALARM CLEAR 10-08-21 9:57AM s 1 OTHER 87 TURBINE WATER ALARM CLEAR 10-08-21 9:56AM L 3 ANNULAR 89 ANNULAR FUEL ALARM CLEAR 10-08-21 9:54AM L 9 PIPE 89 FILL FUEL ALARM CLEAR 10-08-21 9:53AM s 3 OTHER 89 TURBINE INSTALL ALARM CLEAR 10-08-21 9:53AM s 3 OTHER 89 TURBINE WATER ALARM CLEAR 10-08-21 9:52AM s 3 OTHER 89 TURBINE INSTALL ALARM CLEAR 10-08-21 9:52AM L 2 ANNULAR 91 ANNULAR FUEL ALARM CLEAR 10-08-21 9:50AM L 8 PIPE 91 FILL FUEL ALARM CLEAR 10-08-21 9:50AM s 2 OTHER 91 TURBINE INSTALL ALARM CLEAR 10-08-21 9:49AM s 2 OTHER 91 TURBINE WATER ALARM CLEAR 10-08-21 9:48AM s 2 OTHER 91 TURBINE INSTALL ALARM CLEAR 10-08-21 9:48AM L 1 ANNULAR 87 ANNULAR FUEL ALARM CLEAR 10-08-21 9:40AM L 1 ANNULAR 87 ANNULAR FUEL ALARM CLEAR 10-08-21 9:40AM L 1 ANNULAR 87 ANNULAR FUEL ALARM CLEAR 10-08-21 9:39AM L 1 ANNULAR 87 ANNULAR FUEL ALARM CLEAR 10-08-21 9:39AM L 3 ANNULAR 89 ANNULAR FUEL ALARM CLEAR 10-08-21 9:37AM L 2 ANNULAR 91 ANNULAR FUEL ALARM CLEAR 10-08-21 9:33AM SYSTEM PRINTER ERROR CLEAR 9-25-21 5:45AM SYSTEM PAPER OUT CLEAR 9-25-21 5:45AM SYSTEM PRINTER ERROR CLEAR 9-25-21 5:44AM SYSTEM PRINTER ERROR CLEAR 9-25-21 5:43AM SYSTEM PAPER OUT CLEAR 9-25-21 5:43AM OTHER ISD VAPOR LEAK WARN CLEAR 9-13-21 10:38AM OTHER ISD VAPOR LEAK WARN CLEAR 8-27-21 9:29AM h 2 OTHER FP2: BLEND3 DEGRD COLLECT WARN CLEAR 8-13-21 9:00AM SYSTEM PRINTER ERROR CLEAR 8-10-21 7:32AM SYSTEM PAPER OUT CLEAR 8-10-21 7:32AM SYSTEM PRINTER ERROR CLEAR 8-10-21 7:32AM SYSTEM PAPER OUT CLEAR 8-10-21 7:32AM SYSTEM PRINTER ERROR CLEAR 8-10-21 7:30AM SYSTEM PAPER OUT CLEAR 8-10-21 7:30AM OTHER ISD VAPOR LEAK WARN CLEAR 8-07-21 9:05AM OTHER ISD VAPOR LEAK WARN CLEAR 7-29-21 3:05PM OTHER ISD VAPOR LEAK WARN CLEAR 7-21-21 12:41PM OTHER ISD VAPOR LEAK WARN CLEAR 7-09-21 11:39AM h 4 OTHER FP4: BLEND3 DEGRD COLLECT WARN CLEAR 7-08-21 9:00AM SYSTEM PRINTER ERROR CLEAR 7-04-21 7:14AM SYSTEM PAPER OUT CLEAR 7-04-21 7:14AM OTHER ISD SENSOR OUT WARN CLEAR 6-30-21 9:05AM OTHER ISD VAPOR LEAK WARN CLEAR 6-26-21 9:05AM OTHER ISD VAPOR LEAK WARN CLEAR 6-21-21 9:06AM OTHER ISD VAPOR LEAK WARN CLEAR 6-09-21 9:03AM > < I40200 OCT 8, 2021 11:00 AM > < I72300 OCT 8, 2021 11:00 AM CIRCLE K 2708606 1030 OAK ST 661-861-8048 BAKERSFIELD,CA.93304 SMARTSENSOR ASSIGNMENT DEVICE LABEL CATEGORY 01 87 TURBINE MAG SENSOR 02 91 TURBINE MAG SENSOR 03 89 TURBINE MAG SENSOR 04 UNKNOWN 05 UNKNOWN 06 UNKNOWN 07 UNKNOWN 08 UNKNOWN 09 UDC 3-4 AIR FLOW METER 10 UDC 1-2 AIR FLOW METER 11 UDC 1-2 PRESS SENSOR VAPOR PRESSURE 12 UNKNOWN 13 UNKNOWN 14 UNKNOWN 15 UNKNOWN 16 UNKNOWN 17 UNKNOWN 18 UNKNOWN 19 UNKNOWN 20 UNKNOWN 21 UNKNOWN 22 UNKNOWN 23 UNKNOWN 24 UNKNOWN 25 UNKNOWN 26 UNKNOWN 27 UNKNOWN 28 UNKNOWN 29 UNKNOWN 30 UNKNOWN 31 UNKNOWN 32 UNKNOWN 33 UNKNOWN 34 UNKNOWN 35 UNKNOWN 36 UNKNOWN 37 UNKNOWN 38 UNKNOWN 39 UNKNOWN 40 UNKNOWN > < I10200 OCT 8, 2021 11:00 AM CIRCLE K 2708606 1030 OAK ST 661-861-8048 BAKERSFIELD,CA.93304 SYSTEM CONFIGURATION SLOT BOARD TYPE POWER ON RESET CURRENT 1 4 PROBE / G.T. 164601 163792 2 INTERSTITIAL BD 202056 201689 3 INTERSTITIAL BD 201724 201531 4 8SMARTSENSOR BD 39327 39331 5 8SMARTSENSOR BD 39605 39483 6 UNUSED 9991294 9823448 7 UNUSED 9960899 9818862 8 UNUSED 9961727 9817715 9 UNUSED 9957146 9824080 10 RELAY BOARD 14972 14964 11 UNUSED 9947085 9819667 12 UNUSED 9948082 9823756 13 UNUSED 9944389 9820879 14 UNUSED 9940760 9818672 15 UNUSED 9945153 9825530 16 UNUSED 9941863 9826871 COMM 1 RS232 SERIAL BD 14929 14942 COMM 2 ELEC DISP INT. 100863 101034 COMM 3 SERIAL SAT BD 484335 484739 COMM 4 UNUSED 9954874 9826179 COMM 5 UNUSED 9939889 9825205 COMM 6 UNUSED 9946724 9824643 > < I31600 OCT 8, 2021 11:00 AM CIRCLE K 2708606 1030 OAK ST 661-861-8048 BAKERSFIELD,CA.93304 SMART SENSOR ALARM HISTORY REPORT SENSOR LOCATION 1 87 TURBINE OCT 8, 2021 9:57 AM INSTALL ALARM OCT 8, 2021 9:56 AM WATER ALARM SEP 14, 2021 10:41 AM INSTALL ALARM 2 91 TURBINE OCT 8, 2021 9:48 AM INSTALL ALARM OCT 8, 2021 9:48 AM WATER ALARM OCT 8, 2021 9:46 AM INSTALL ALARM 3 89 TURBINE OCT 8, 2021 9:52 AM INSTALL ALARM OCT 8, 2021 9:52 AM WATER ALARM OCT 8, 2021 9:52 AM INSTALL ALARM 9 UDC 3-4 10 UDC 1-2 11 UDC 1-2 PRESS SENSOR >