Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
2021 FMC & OPI Test - PASS
1 Jennifer Pruitt Subject:SA002, AT&T Annual Monitor Certification & Spill Bucket Testing Notification w/Overfill Test (BKFDCA01), Bakersfield Location:1520 20TH ST, BAKERSFIELD, CA 93301-4406 Start:Fri 10/29/2021 8:30 AM End:Fri 10/29/2021 10:30 AM Recurrence:(none) Meeting Status:Meeting organizer Organizer:Simplex Communication Required Attendees:AGUILAR, ADOLFO; Knoche, Rebecca (rk9575@att.com) ; 'FLORES, CECILIA'; AT&T CA Testing; 'HAYN, CINDY H (ATTSI)' (ch1921@att.com) ; Brian Harmon; Carlos Cardenas; Jennifer Pruitt; Maria Figueroa; 'Alex Coronado'; Jon Larsen Categories:Annual Monitoring Certification & Spill Bucket Testing, Legacy T Site There is an AT&T Annual Monitoring Certification & Spill Bucket Test scheduled for this location on the date and time indicated. NOTE: -Testing will include the Overfill Test of the Overfill alarm SA002 1520 20TH ST BAKERSFIELD 93301-4406 TEST DUE DATE 10/15/2021 PERMIT REQUIRED for TESTING Please contact the Compliance Manager with any questions and/or comments at: simplexcommunication@tait.com 714.560.8200 Environmental Health/CUPA Contact Information: Bakersfield City Fire Department 2101 H Street Bakersfield, CA 93301 Method of Notification: Email 2 Contact: Kristopher Karns KKarns@bakersfieldfire.us Test Results Submittal: USTResults@bakersfieldfire.us 1 Jennifer Pruitt From:Peter Armagost <parmagost@bakersfieldfire.us> Sent:Thursday, October 28, 2021 11:05 AM To:Carlos Cardenas Cc:Jennifer Pruitt; AGUILAR, ADOLFO; Erin Langford; Randy Novak; Jon Larsen Subject:Re: [External] SCHEDULING REQUEST*** AT&T OCTOBER Annual Testing - Bakersfield Carlos, Our day starts at 8 AM. we can start at 8:30 if you’re ok with that? Peter Armagost | Fire Prevention Officer City of Bakersfield Email: parmagost@bakersfieldfire.us Web: www.bakersfieldfire.us Phone: 661‐326‐3697 On Oct 27, 2021, at 8:59 PM, Carlos Cardenas <ccardenas@tait.com> wrote: I think 7:00 AM would be great, if possible Carlos E. Cardenas Tait Environmental Services, Inc. (714) 567-6418 From: Peter Armagost <parmagost@bakersfieldfire.us> Sent: Wednesday, October 27, 2021 4:51 PM To: Carlos Cardenas <ccardenas@TAIT.COM> Cc: Jennifer Pruitt <jpruitt@TAIT.COM>; AGUILAR, ADOLFO <aa376w@att.com>; Erin Langford <elangford@TAIT.COM>; Randy Novak <rnovak@TAIT.COM>; Jon Larsen <jonlarsen@TAIT.COM> Subject: Re: [External] SCHEDULING REQUEST*** AT&T OCTOBER Annual Testing ‐ Bakersfield How early are you wanting to start? Peter Armagost | Fire Prevention Officer City of Bakersfield Email: parmagost@bakersfieldfire.us Web: www.bakersfieldfire.us Phone: 661‐326‐3697 2 On Oct 27, 2021, at 4:46 PM, Carlos Cardenas <ccardenas@tait.com> wrote: Hello Inspector Armagost, Would you be available to start the testing early on Friday? Carlos E. Cardenas Tait Environmental Services, Inc. (714) 567-6418 From: Peter Armagost <parmagost@bakersfieldfire.us> Sent: Wednesday, September 29, 2021 4:07 PM To: Carlos Cardenas <ccardenas@TAIT.COM> Cc: Jennifer Pruitt <jpruitt@TAIT.COM>; AGUILAR, ADOLFO <aa376w@att.com>; Erin Langford <elangford@TAIT.COM>; Randy Novak <rnovak@TAIT.COM> Subject: RE: [External] SCHEDULING REQUEST*** AT&T OCTOBER Annual Testing ‐ Bakersfield Carlos, You are confirmed for all the dates now. Thank you for working with me. Peter Armagost | Fire Prevention Officer Bakersfield Fire Department City of Bakersfield email:parmagost@bakersfieldfire.us web: www.bakersfieldfire.us phone: 661-326-3697 From: Carlos Cardenas <ccardenas@TAIT.COM> Sent: Wednesday, September 29, 2021 4:03 PM To: Peter Armagost <parmagost@bakersfieldfire.us> Cc: Jennifer Pruitt <jpruitt@TAIT.COM>; AGUILAR, ADOLFO <aa376w@att.com>; Erin Langford <elangford@TAIT.COM>; Randy Novak <rnovak@TAIT.COM> Subject: RE: [External] SCHEDULING REQUEST*** AT&T OCTOBER Annual Testing ‐ Bakersfield Importance: High Thank you sir. We can make the following changes SA098, AT&T Annual Monitor Certification & Spill Bucket Testing Notification w/Overfill Test (BKFDCA14), Bakersfield 3221 S. H STREET, BAKERSFIELD, C SA002, AT&T Annual Monitor Certification & Spill Bucket Testing Notification w/Overfill Test (BKFDCA01), Bakersfield 1520 20TH ST, BAKERSFIELD, CA 9 3 SA004, AT&T Annual Monitor Certification, PLLD Testing & Spill Bucket Testing Notification (BKFDCA12), Bakersfield 1918 M STREET, BAKERSFIELD, CA SA004, AT&T Annual Precision Line Testing Notification (BKFDCA12), Bakersfield 1918 M STREET, BAKERSFIELD, CA Carlos E. Cardenas Tait Environmental Services, Inc. (714) 567-6418 From: Peter Armagost <parmagost@bakersfieldfire.us> Sent: Wednesday, September 29, 2021 3:58 PM To: Carlos Cardenas <ccardenas@TAIT.COM> Cc: Jennifer Pruitt <jpruitt@TAIT.COM>; AGUILAR, ADOLFO <aa376w@att.com> Subject: RE: [External] SCHEDULING REQUEST*** AT&T OCTOBER Annual Testing ‐ Bakersfield Carlos, You are confirmed for the 15th at 1918 M STREET, however the other dates you requested are already taken. I have the 20th & 29th open. Please let me know if these dates work for you. Peter Armagost | Fire Prevention Officer Bakersfield Fire Department City of Bakersfield email:parmagost@bakersfieldfire.us web: www.bakersfieldfire.us phone: 661-326-3697 From: Carlos Cardenas <ccardenas@TAIT.COM> Sent: Wednesday, September 29, 2021 3:36 PM To: Peter Armagost <parmagost@bakersfieldfire.us> Cc: Jennifer Pruitt <jpruitt@TAIT.COM>; AGUILAR, ADOLFO <aa376w@att.com> Subject: SCHEDULING REQUEST*** AT&T OCTOBER Annual Testing ‐ Bakersfield Importance: High Hello Inspector Armagost, Below is the test events that we will need to scheduled for October. Please confirm and feel free to contact me with any questions and/or comments. SA098, AT&T Annual Monitor Certification & Spill Bucket Testing Notification w/Overfill Test (BKFDCA14), Bakersfield 3221 S. H STREET, BAKERSFIELD, C 4 SA002, AT&T Annual Monitor Certification & Spill Bucket Testing Notification w/Overfill Test (BKFDCA01), Bakersfield 1520 20TH ST, BAKERSFIELD, CA 9 SA004, AT&T Annual Monitor Certification, PLLD Testing & Spill Bucket Testing Notification (BKFDCA12), Bakersfield 1918 M STREET, BAKERSFIELD, CA SA004, AT&T Annual Precision Line Testing Notification (BKFDCA12), Bakersfield 1918 M STREET, BAKERSFIELD, CA Carlos E. Cardenas Tait Environmental Services, Inc. (714) 567-6418 From: Malcolm W. Moore <mwmoore@bakersfieldfire.us> Sent: Wednesday, September 29, 2021 3:12 PM To: Jerry Rangel <jerryr@calvalley.com> (jerryr@calvalley.com) <jerryr@calvalley.com>; Carlos Cardenas <ccardenas@TAIT.COM>; marcus btssc.com <marcus@btssc.com>; Jamie <jamie1.res@gmail.com>; john.culver@jcincorp.net; bianca@jcincorp.net; kellybssr <kellybssr@gmail.com>; Janelle Dockham (Janelle@ustservices.com) <janelle@ustservices.com>; Johnny Kassis <jkassis@tanknology.com>; mlindsey@tanknology.com; Karli <karli@ustservices.com> Cc: Peter Armagost <parmagost@bakersfieldfire.us> Subject: [External] UST Permits The following UST permits have been approved. Be aware that Peter is very busy with UST inspections and scheduling times may be longer than usual. 1601 Truxtun‐‐OPI 1918 M Street‐‐FMC & line testing 3221 S H Street‐‐FMC 1520 20th Street‐‐FMC 5600 Auburn‐‐FMC / OPI 1030 Oak St‐‐FMC / OPI 5634 Stine‐‐FMC 3221 Taft HWY‐‐ minor mod 5625 Gosford‐‐minor mod / FMC 4012 White Ln‐‐minor mod 6450 White Ln‐‐minor mod 3501 Mt. Vernon‐‐minor mod 3200 F Street‐‐SB 989 4201 Belle Terrace‐‐FMC / OPI 2500 Wible‐‐FMC / OPI 2600 White Ln‐‐minor mod 4012 White Ln‐‐FMC Thank You, Malcolm Moore, REPA Hazardous Materials Specialist Bakersfield Fire Department 5 661‐326‐3684 Appendix VI Underground Storage Tank Monitoring System Certification Form CERS = California Environmental Reporting System, GPH = Gallons Per Hour, ID = Identification, ICC = International Code Council, LLD = Line Leak Detector, NA = Not Applicable, SW = Single- Walled, UDC = Under-Dispenser Containment, UST = Underground Storage Tank, VPH = Vacuum/Pressure/Hydrostatic Page 1 of 6 TYPE OF ACTION ܆܆ Installation ܆ Repair ܆ 12 Month 1. FACILITY INFORMATION CERS ID Certification Date Facility Name Facility Address City ZIP Code 2. SERVICE TECHNICIAN INFORMATION Company Performing the Certification Phone Mailing Address Service Technician Performing Test Contractor/Tank Tester License Number ICC Number ICC Expiration Date 3. TRAINING AND CERTIFICATIONS Manufacturer and Test Equipment Training Certifications Expiration Date 4. CERTIFICATION BY SERVICE TECHNICIAN CONDUCTING TEST I hereby certify that the monitoring system is operational in accordance with California Code of Regulations, title 23, division 3, chapter 16, section 2638; that required supporting documentation is attached; and all information contained herein is accurate. Service Technician Signature Date Total # of Pages SA002 ✔ 10029370 10/29/2021 Pacific Bell Telephone Co. dba AT&T California 1520 20th St.Bakersfield 93301 TAIT Environmental Services, Inc. (714) 560-8222 701 N. Parkcenter Dr., Santa Ana, CA 92705 Jon Larsen 588098 8144945 05/12/2022 VeederRoot B41757 03/10/2023 10/29/2021 Underground Storage Tank Monitoring System Certification Form Page 2 of 6 5. MONITORING SYSTEM AND PROGRAMMING A separate Monitoring System Certification Form must be prepared for each control panel. Make of Monitoring System Control Panel Model of Monitoring System Control Panel Software Version Installed Attach the post-certification reports if the monitoring system is capable of generating either;܆܆Monitoring System Set-up ܆܆ Alarm History Report Yes No NA All monitoring equipment is operational per manufacturer’s specifications?܆܆܆܆ Secondary containment systems are free of damage, debris, or liquid?܆܆܆܆ Are the audible and visual alarms operational?܆܆܆܆ All sensors have been: 1) visually inspected for wiring kinks, breaks and residual buildup on floats; and 2) tested for functionality and confirmed operational?܆܆܆܆܆܆ Are all sensors installed to detect a release at the earliest opportunity in the secondary containment?܆܆܆܆܆܆ The monitoring system set-up was reviewed, and proper settings confirmed?܆܆܆܆܆܆ Was the monitoring control panel’s backup battery visually inspected, functionally tested, and confirmed operational?܆܆܆܆܆܆ Does the flow of fuel stop at the dispenser if a release is detected in the under- dispenser containment?܆܆܆܆܆܆ Does the turbine automatically shut down if the piping secondary containment monitoring system fails to operate or is electrically disconnected?܆܆܆܆܆܆ Does the turbine automatically shut down if the piping secondary containment monitoring system detects a release? Which sensors initiate positive shut down? (Check all that apply)܆ Sump ܆ UDC ܆܆܆܆܆܆ If monitoring system alarms are relayed to a remote monitoring center, is all communication equipment operational?܆܆܆܆܆܆ Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 VeederRoot TLS 350 Plus 120.00 ✔✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ Underground Storage Tank Monitoring System Certification Form Page 3 of 6 6. SENSOR TESTING RESULTS List only sensors tested on date of this certification. List “Sensor ID” as labeled in system programming. Additional copies of this page may be attached to accommodate all sensors tested. Sensor ID Sensor Model Component(s) Monitored Pass Fail ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 L-1 794380-208 / N/A Fill Sump Sensor ✔ L-2 794380-208 / N/A Piping Sump Sensor ✔ L-3 794380-208 / 454053 Day Tank Containment Pan Sensor ✔ L-4 794380-208 / 454345 AST Day Tank Annular Sensor ✔ L-5 794390-420 / 453457 UST Tank Annular Sensor ✔ L-6 794380-208 / 877657 Transition Piping Sump Sensor ✔ L-7 794380-208 / N/A Remote Pump Cabinet Sensor ✔ Underground Storage Tank Monitoring System Certification Form Page 4 of 6 7. LINE LEAK DETECTOR TESTING ܆܆ Check this box if line leak detectors ARE NOT installed. (Do not complete this section.) Simulated release rate verified: (Check all that apply.) ܆܆ 3 GPH ܆܆ 0.1 GPH ܆܆ 0.2 GPH Yes No NA Has the testing apparatus been properly calibrated?܆܆ ܆܆ ܆܆ For emergency generator tank systems, does the LLD create an audible and visual alarm when a leak is detected?܆܆ ܆܆ ܆܆ For mechanical LLDs, does the LLD restrict the flow through the pipe when a release is detected?܆܆ ܆܆ ܆܆ For electronic LLDs, does the turbine automatically shut off when a release is detected?܆܆ ܆܆ ܆܆ For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system is disabled or disconnected?܆܆ ܆܆ ܆܆ For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system malfunctions or fails a tightness test?܆܆ ܆܆ ܆܆ For electronic LLDs, have all accessible wiring connections been visually inspected for kinks and breaks?܆܆ ܆܆ ܆܆ Were all items on the equipment manufacturer’s maintenance checklist completed?܆܆ ܆܆ ܆܆ Were all LLDs confirmed operational within regulatory requirements?܆܆ ܆܆ ܆܆ LLD ID LLD Model Lines Monitored Pass Fail ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 ✔ Underground Storage Tank Monitoring System Certification Form Page 5 of 6 8. IN-TANK GAUGING TESTING ܆܆ Check this box if tank gauging is used only for inventory control. ܆܆ Check this box if NO tank gauging equipment is installed. (Do not complete this section if either box is checked.) Yes No NA All wiring has been: 1) visually inspected for kinks, breaks and proper entry and termination; and 2) tested for ground faults?܆܆ ܆܆ ܆܆ Were all in-tank gauging probes visually inspected for damage and residue buildup to ensure that floats move freely, functionally tested, and confirmed operational?܆܆ ܆܆ ܆܆ Was accuracy of system’s product level readings tested?܆܆ ܆܆ ܆܆ Was accuracy of system’s water level readings tested?܆܆ ܆܆ ܆܆ Were all probes reinstalled properly?܆܆ ܆܆ ܆܆ Were all items on the equipment manufacturer’s maintenance checklist completed?܆܆ ܆܆ ܆܆ Probe ID Probe Model Tanks Monitored Pass Fail ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ 9. COMMENTS Describe all answers marked “No” or “Fail” and proposed remedy. List all monitoring equipment either replaced or repaired. ✔ ✔ ✔ ✔ ✔ ✔ ✔ T-1 846390-105 / 234300 SA002U001 Diesel Tank (UST Main Tank) ✔ T-2 847390-301 / 620656 SA002A002 Diesel Tank (AST Day Tank ) ✔ D-1 Autodial failure due to server issue on other end. Sensors alarmed and certified received by EHS. Replaced TLS back up battery prior to testing. Underground Storage Tank Monitoring System Certification Form Page 6 of 6 10. MONITORING SITE PLAN Date site plan was prepared: If a site plan has been prepared that shows all required information, you may include it, rather than this page, with your Monitoring System Certification Form. The site plan must show the general layout of tanks and identify locations of the monitoring panel, and all leak detection equipment and monitoring locations. Include a legend for all symbols depicted. 10/29/2021 Appendix IX Underground Storage Tank Overfill Prevention Equipment Inspection Report Form CERS = California Environmental Reporting System, ID = Identification, ICC = International Code Council, OPE = Overfill Prevention Equipment Page 1 of 2 TYPE OF ACTION ܆܆ Installation ܆ Repair ܆ 36 Month 1. FACILITY INFORMATION CERS ID Inspection Date Facility Name Facility Address City ZIP Code 2. SERVICE TECHNICIAN INFORMATION Company Performing the Inspection Phone Mailing Address Service Technician Performing Inspection Contractor/Tank Tester License Number ICC Number Expiration Date 3. TRAINING AND CERTIFICATIONS Manufacturer and Test Equipment Training Certifications Expiration Date 4. INSPECTION PROCEDURES INFORMATION Inspection Procedures Used Components Inspected 5. CERTIFICATION BY SERVICE TECHNICIAN CONDUCTING INSPECTION I hereby certify that the OPE was inspected in accordance with California Code of Regulations, title 23, division 3, chapter 16, section 2637.2; that required supporting documentation is attached; and all information contained herein is accurate. I understand that test procedures shall be made available upon request by the governing authority. Service Technician Signature Date Total # of Pages SA002 ✔ 10029370 10/29/2021 Pacific Bell Telephone Co. dba AT&T California 1520 20th St. Bakersfield 93301 TAIT Environmental Services, Inc. (714) 560-8222 701 N. Parkcenter Dr., Santa Ana, CA 92705 Jon Larsen 588098 8144945 05/12/2022 VeederRoot B41757 03/10/2023 Manufacture guidelines SA002U001 846390-105 / 234300 10/29/2021 Underground Storage Tank Overfill Prevention Equipment Inspection Report Additional copies of this page may be attached. Attach tank chart(s), measurements, calculations, and In-Tank Setup report(s) Page 2 of 2 6. OVERFILL PREVENTION EQUIPMENT DETAILS Tank ID (one OPE per column) Are both vent and tank riser piping secondarily contained? ܆܆ Yes ܆܆ No ܆܆ Yes ܆܆ No ܆܆ Yes ܆܆ No ܆܆ Yes ܆܆ No OPE Model What is the OPE response when activated? (Check all that apply.) ܆܆ Shut off Flow ܆܆Restricts Flow ܆܆ Audible Alarm ܆܆ Visual Alarm ܆܆ Shut off Flow ܆܆Restricts Flow ܆܆ Audible Alarm ܆܆ Visual Alarm ܆܆ Shut off Flow ܆܆Restricts Flow ܆܆ Audible Alarm ܆܆ Visual Alarm ܆܆ Shut off Flow ܆܆Restricts Flow ܆܆ Audible Alarm ܆܆ Visual Alarm Are flow restrictors installed on vent piping that may interfere with the OPE operation? ܆܆ Yes ܆܆ No ܆܆ Yes ܆܆ No ܆܆ Yes ܆܆ No ܆܆ Yes ܆܆ No At what level in the tank is the OPE set to activate? (Inches from bottom of tank) What is the percent capacity of the tank at which the OPE activates? Is the OPE in proper operating condition to respond when the stored substance reaches the designated regulatory level? ܆܆ Yes ܆܆ No ܆܆ Yes ܆܆ No ܆܆ Yes ܆܆ No ܆܆ Yes ܆܆ No 7. SUMMARY OF TESTING RESULTS OPE Inspection Results ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail 1 8. COMMENTS Describe all results marked “Fail” and each proposed remedy. * Mark here if: ܆܆ Flow restrictors interfere with overfill prevention and equipment repairs required. SA002U001 ✔ 790091-001 ✔ ✔ ✔ 69.2" 90% ✔ ✔ Per MRP Main Overfill Prevention Is The Overfill Alarm, No Other Components Inspected If Present. If Flow Restrictors Are Present They Don't Interfere w/ Operation Of The A/V Alarm. Appendix VIII Underground Storage Tank Spill Container Testing Report Form CERS = California Environmental Reporting System, ID = Identification, ICC = International Code Council Page 1 of 2 TYPE OF ACTION ܆܆ Installation ܆ Repair ܆ 12 Month 1. FACILITY INFORMATION CERS ID Test Date Facility Name Facility Address City ZIP Code 2. SERVICE TECHNICIAN INFORMATION Company Performing the Test Phone Mailing Address Service Technician Performing Test Contractor/Tank Tester License Number ICC Number ICC Expiration Date 3. TRAINING AND CERTIFICATIONS Manufacturer and Test Equipment Training Certifications Expiration Date 4. TEST PROCEDURE INFORMATION Test Procedures Used Components Tested 5. CERTIFICATION BY SERVICE TECHNICIAN CONDUCTING TEST I hereby certify that each spill container was tested in accordance with California Code of Regulations, title 23, division 3, chapter 16, section 2637.1; that required supporting documentation is attached; and all information contained herein is accurate. I understand that test procedures shall be made available upon request by the governing authority. Service Technician Signature Date Total # of Pages SA002 ✔ 10029370 10/29/2021 Pacific Bell Telephone Co. dba AT&T California 1520 20th St. Bakersfield 93301 TAIT Environmental Services, Inc. (714) 560-8222 701 N. Parkcenter Dr., Santa Ana, CA 92705 Jon Larsen 588098 8144945 05/12/2022 CNI 3717 2/28/2022 PEIRP-1200 SA002U001 Philtite Spill Bucket 10/29/2021 Underground Storage Tank Spill Container Testing Report Form Additional copies of this page may be attached. Page 2 of 2 6. SPILL CONTAINER DETAILS Test Method Developed by ܆܆ Manufacturer ܆܆ Industry Standard ܆܆ Professional Engineer Test Type ܆܆ Pressure ܆܆ Vacuum ܆܆ Hydrostatic Tank ID Spill Container Manufacturer: Method of Cathodic Protection ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other Is the spill container minimum capacity five gallons excluding riser volume? ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* Method to keep spill container empty ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other Spill Container Test Results ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail Tank ID Spill Container Manufacturer: Method of Cathodic Protection ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other Is the spill container minimum capacity five gallons excluding riser volume? ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* Method to keep spill container empty ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other Spill Container Test Results ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail 1 8. COMMENTS Describe all answers marked “Other,” “No,” or “Fail” and each proposed remedy. * Mark here if: Spill containers do not have a minimum capacity of five gallons and require replacement. ✔ ✔ SA002U001 CNI ✔ ✔ ✔ ✔ Returned test water to TAIT. I50301 NOV 1, 2021 8:10 AM # 1:BKFDCA01 SA002 T-S I50302 NOV 1, 2021 8:10 AM # 2:1520 20TH ST I50303 NOV 1, 2021 8:10 AM # 3:BAKERSFIELD,CA 93301 I50304 NOV 1, 2021 8:10 AM # 4:661-869-1846 I51700 NOV 1, 2021 8:10 AM SYSTEM TYPE AND LANGUAGE FLAG SYSTEM UNITS U.S. SYSTEM LANGUAGE ENGLISH SYSTEM DATE/TIME FORMAT MON DD YYYY HH:MM:SS xM I50F00 NOV 1, 2021 8:11 AM MON DD YYYY HH:MM:SS xM I10200 NOV 1, 2021 8:11 AM BKFDCA01 SA002 T-S 1520 20TH ST BAKERSFIELD,CA 93301 661-869-1846 SYSTEM CONFIGURATION SLOT BOARD TYPE POWER ON RESET CURRENT 1 4 PROBE / G.T. 162295 162111 2 INTERSTITIAL BD 201439 200911 3 UNUSED 15000000 15000000 4 UNUSED 15000000 15000000 5 UNUSED 15000000 15000000 6 UNUSED 15000000 15000000 7 UNUSED 15000000 15000000 8 UNUSED 15000000 15000000 9 RELAY BOARD 14933 14977 10 COMBO I/O BOARD 9929 9933 11 UNUSED 15000000 15000000 12 UNUSED 15000000 15000000 13 UNUSED 15000000 15000000 14 UNUSED 15000000 15000000 15 UNUSED 15000000 15000000 16 UNUSED 15000000 15000000 COMM 1 FAXMODEM BOARD 40571 40577 COMM 2 UNUSED 15000000 15000000 COMM 3 UNUSED 15000000 15000000 COMM 4 UNUSED 15000000 15000000 COMM 5 UNUSED 15000000 15000000 COMM 6 UNUSED 15000000 15000000 I60100 NOV 1, 2021 8:11 AM TANK CONFIGURATION DEVICE LABEL CONFIGURED 1 DIESEL TK#SA002U001 ON 2 DIESEL TK#SA002A002 ON 3 OFF 4 OFF I60200 NOV 1, 2021 8:11 AM TANK PRODUCT LABEL TANK PRODUCT LABEL 1 DIESEL TK#SA002U001 2 DIESEL TK#SA002A002 3 4 I60300 NOV 1, 2021 8:11 AM TANK PRODUCT CODE TANK PRODUCT LABEL 1 DIESEL TK#SA002U001 1 2 DIESEL TK#SA002A002 1 3 3 4 4 I60400 NOV 1, 2021 8:11 AM TANK FULL VOLUME TANK PRODUCT LABEL GALLONS 1 DIESEL TK#SA002U001 8002 2 DIESEL TK#SA002A002 250 3 0 4 0 I60700 NOV 1, 2021 8:11 AM TANK DIAMETER TANK PRODUCT LABEL INCHES 1 DIESEL TK#SA002U001 82.00 2 DIESEL TK#SA002A002 30.00 3 0.00 4 0.00 I60900 NOV 1, 2021 8:11 AM TANK THERMAL COEFFICIENT TANK PRODUCT LABEL 1 DIESEL TK#SA002U001 0.000450 2 DIESEL TK#SA002A002 0.000450 3 0.000000 4 0.000000 I61200 NOV 1, 2021 8:11 AM TANK MANIFOLDED PARTNERS TANK PRODUCT LABEL MANIFOLDED TANKS 1 DIESEL TK#SA002U001 NONE 2 DIESEL TK#SA002A002 NONE 3 NONE 4 NONE I62100 NOV 1, 2021 8:11 AM TANK LOW PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 DIESEL TK#SA002U001 4000 2 DIESEL TK#SA002A002 105 3 0 4 0 I62200 NOV 1, 2021 8:11 AM TANK HIGH PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 DIESEL TK#SA002U001 7601 2 DIESEL TK#SA002A002 237 3 0 4 0 I62300 NOV 1, 2021 8:11 AM TANK OVERFILL LEVEL LIMIT TANK PRODUCT LABEL GALLONS 1 DIESEL TK#SA002U001 7201 2 DIESEL TK#SA002A002 225 3 0 4 0 I62400 NOV 1, 2021 8:11 AM TANK HIGH WATER LEVEL LIMIT TANK PRODUCT LABEL INCHES 1 DIESEL TK#SA002U001 2.0 2 DIESEL TK#SA002A002 2.0 I62800 NOV 1, 2021 8:12 AM TANK MAXIMUM VOLUME LIMIT TANK PRODUCT LABEL GALLONS 1 DIESEL TK#SA002U001 8002 2 DIESEL TK#SA002A002 250 3 0 4 0 I62900 NOV 1, 2021 8:12 AM TANK DELIVERY REQUIRED LIMIT TANK PRODUCT LABEL GALLONS 1 DIESEL TK#SA002U001 4000 2 DIESEL TK#SA002A002 125 3 0 4 0 I70300 NOV 1, 2021 8:12 AM LIQUID TYPE SENSOR LOCATION TYPE 1 FILL SUMP TRI-STATE (SINGLE FLOAT) 2 PIPING SUMP TRI-STATE (SINGLE FLOAT) 3 DAYTANK RUPTURE BASN TRI-STATE (SINGLE FLOAT) 4 DAY TANK ANNULAR TRI-STATE (SINGLE FLOAT) 5 ANNULAR UST TRI-STATE (SINGLE FLOAT) 6 TRANSITION SUMP TRI-STATE (SINGLE FLOAT) 7 REMOTE PUMP CABINET TRI-STATE (SINGLE FLOAT) 8 TRI-STATE (SINGLE FLOAT) I90200 NOV 1, 2021 8:12 AM SOFTWARE REVISION LEVEL VERSION 120.00 SOFTWARE# 346120-100-A CREATED - 00.07.28.15.33 S-MODULE# 330160-002-A SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS CSLD I11100 NOV 1, 2021 8:12 AM BKFDCA01 SA002 T-S 1520 20TH ST BAKERSFIELD,CA 93301 661-869-1846 PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME D 1 OTHER CALL CENTER AUTODIAL FAILURE CLEAR 10-29-21 10:05AM D 1 OTHER CALL CENTER AUTODIAL FAILURE ALARM 10-29-21 10:02AM D 1 OTHER CALL CENTER AUTODIAL FAILURE CLEAR 10-29-21 9:48AM T 2 TANK DIESEL TK#SA002A002 HIGH WATER ALARM CLEAR 10-29-21 9:43AM T 2 TANK DIESEL TK#SA002A002 PROBE OUT CLEAR 10-29-21 9:43AM T 2 TANK DIESEL TK#SA002A002 PROBE OUT ALARM 10-29-21 9:42AM T 2 TANK DIESEL TK#SA002A002 HIGH WATER ALARM ALARM 10-29-21 9:40AM T 2 TANK DIESEL TK#SA002A002 MAX PRODUCT ALARM CLEAR 10-29-21 9:35AM T 2 TANK DIESEL TK#SA002A002 MAX PRODUCT ALARM ALARM 10-29-21 9:35AM T 2 TANK DIESEL TK#SA002A002 MAX PRODUCT ALARM CLEAR 10-29-21 9:33AM T 2 TANK DIESEL TK#SA002A002 MAX PRODUCT ALARM ALARM 10-29-21 9:33AM T 2 TANK DIESEL TK#SA002A002 PROBE OUT CLEAR 10-29-21 9:33AM T 2 TANK DIESEL TK#SA002A002 PROBE OUT ALARM 10-29-21 9:31AM D 1 OTHER CALL CENTER AUTODIAL FAILURE ALARM 10-29-21 9:29AM D 1 OTHER CALL CENTER AUTODIAL FAILURE CLEAR 10-29-21 9:29AM L 3 OTHER DAYTANK RUPTURE BASN FUEL ALARM CLEAR 10-29-21 9:29AM L 3 OTHER DAYTANK RUPTURE BASN FUEL ALARM ALARM 10-29-21 9:29AM L 4 ANNULAR DAY TANK ANNULAR FUEL ALARM CLEAR 10-29-21 9:27AM L 4 ANNULAR DAY TANK ANNULAR FUEL ALARM ALARM 10-29-21 9:27AM T 1 TANK DIESEL TK#SA002U001 HIGH WATER ALARM CLEAR 10-29-21 9:20AM T 1 TANK DIESEL TK#SA002U001 PROBE OUT CLEAR 10-29-21 9:20AM T 1 TANK DIESEL TK#SA002U001 PROBE OUT ALARM 10-29-21 9:19AM T 1 TANK DIESEL TK#SA002U001 HIGH WATER ALARM ALARM 10-29-21 9:17AM T 1 TANK DIESEL TK#SA002U001 OVERFILL ALARM CLEAR 10-29-21 9:14AM T 1 TANK DIESEL TK#SA002U001 OVERFILL ALARM ALARM 10-29-21 9:12AM T 1 TANK DIESEL TK#SA002U001 LOW PRODUCT ALARM CLEAR 10-29-21 9:11AM D 1 OTHER CALL CENTER AUTODIAL FAILURE ALARM 10-29-21 9:11AM D 1 OTHER CALL CENTER AUTODIAL FAILURE CLEAR 10-29-21 9:11AM T 1 TANK DIESEL TK#SA002U001 PROBE OUT CLEAR 10-29-21 9:11AM T 1 TANK DIESEL TK#SA002U001 PROBE OUT ALARM 10-29-21 9:10AM T 1 TANK DIESEL TK#SA002U001 LOW PRODUCT ALARM ALARM 10-29-21 9:10AM L 6 PIPE TRANSITION SUMP FUEL ALARM CLEAR 10-29-21 9:01AM L 6 PIPE TRANSITION SUMP FUEL ALARM ALARM 10-29-21 9:01AM L 7 OTHER REMOTE PUMP CABINET FUEL ALARM CLEAR 10-29-21 8:58AM L 7 OTHER REMOTE PUMP CABINET FUEL ALARM ALARM 10-29-21 8:57AM D 1 OTHER CALL CENTER AUTODIAL FAILURE ALARM 10-29-21 8:50AM L 1 STP SUMP FILL SUMP FUEL ALARM CLEAR 10-29-21 8:50AM L 1 STP SUMP FILL SUMP FUEL ALARM ALARM 10-29-21 8:49AM L 5 ANNULAR ANNULAR UST FUEL ALARM CLEAR 10-29-21 8:42AM L 5 ANNULAR ANNULAR UST FUEL ALARM ALARM 10-29-21 8:40AM L 2 PIPE PIPING SUMP FUEL ALARM CLEAR 10-29-21 8:38AM L 2 PIPE PIPING SUMP FUEL ALARM ALARM 10-29-21 8:37AM L 2 PIPE PIPING SUMP FUEL ALARM CLEAR 10-25-21 9:30PM L 2 PIPE PIPING SUMP FUEL ALARM ALARM 10-25-21 5:05PM L 1 STP SUMP FILL SUMP FUEL ALARM CLEAR 5-21-21 9:15AM L 1 STP SUMP FILL SUMP FUEL ALARM ALARM 5-21-21 9:15AM T 2 TANK DIESEL TK#SA002A002 MAX PRODUCT ALARM CLEAR 10-15-20 9:50AM T 2 TANK DIESEL TK#SA002A002 PROBE OUT CLEAR 10-15-20 9:50AM T 2 TANK DIESEL TK#SA002A002 PROBE OUT ALARM 10-15-20 9:49AM T 2 TANK DIESEL TK#SA002A002 MAX PRODUCT ALARM ALARM 10-15-20 9:46AM I11200 NOV 1, 2021 8:13 AM BKFDCA01 SA002 T-S 1520 20TH ST BAKERSFIELD,CA 93301 661-869-1846 NON-PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME T 2 TANK DIESEL TK#SA002A002 HIGH WATER WARNING CLEAR 10-29-21 9:43AM T 2 TANK DIESEL TK#SA002A002 HIGH WATER WARNING ALARM 10-29-21 9:40AM T 2 TANK DIESEL TK#SA002A002 HIGH PRODUCT ALARM CLEAR 10-29-21 9:35AM T 2 TANK DIESEL TK#SA002A002 HIGH PRODUCT ALARM ALARM 10-29-21 9:35AM T 2 TANK DIESEL TK#SA002A002 HIGH PRODUCT ALARM CLEAR 10-29-21 9:33AM T 2 TANK DIESEL TK#SA002A002 HIGH PRODUCT ALARM ALARM 10-29-21 9:33AM T 2 TANK DIESEL TK#SA002A002 INVALID FUEL LEVEL CLEAR 10-29-21 9:33AM T 2 TANK DIESEL TK#SA002A002 INVALID FUEL LEVEL ALARM 10-29-21 9:33AM T 1 TANK DIESEL TK#SA002U001 HIGH WATER WARNING CLEAR 10-29-21 9:20AM T 1 TANK DIESEL TK#SA002U001 HIGH WATER WARNING ALARM 10-29-21 9:17AM T 1 TANK DIESEL TK#SA002U001 HIGH PRODUCT ALARM CLEAR 10-29-21 9:12AM T 1 TANK DIESEL TK#SA002U001 HIGH PRODUCT ALARM ALARM 10-29-21 9:12AM T 1 TANK DIESEL TK#SA002U001 DELIVERY NEEDED CLEAR 10-29-21 9:11AM T 1 TANK DIESEL TK#SA002U001 DELIVERY NEEDED ALARM 10-29-21 9:10AM SYSTEM PRINTER ERROR CLEAR 10-25-21 7:16PM SYSTEM PRINTER ERROR ALARM 10-25-21 7:16PM SYSTEM PRINTER ERROR CLEAR 10-25-21 7:14PM SYSTEM PRINTER ERROR ALARM 10-25-21 7:12PM SYSTEM PRINTER ERROR CLEAR 10-25-21 7:10PM SYSTEM PRINTER ERROR ALARM 10-25-21 7:10PM SYSTEM PRINTER ERROR CLEAR 10-25-21 6:52PM SYSTEM PRINTER ERROR ALARM 10-25-21 6:51PM SYSTEM SOFTWARE MODULE WARN CLEAR 9-08-21 4:40PM SYSTEM SOFTWARE MODULE WARN ALARM 9-08-21 4:40PM SYSTEM SOFTWARE MODULE WARN CLEAR 9-08-21 4:35PM SYSTEM SOFTWARE MODULE WARN ALARM 9-08-21 4:35PM SYSTEM PRINTER ERROR CLEAR 10-15-20 10:24AM SYSTEM PAPER OUT CLEAR 10-15-20 10:24AM SYSTEM PRINTER ERROR ALARM 10-15-20 10:24AM SYSTEM PAPER OUT ALARM 10-15-20 10:24AM T 2 TANK DIESEL TK#SA002A002 HIGH PRODUCT ALARM CLEAR 10-15-20 9:50AM T 2 TANK DIESEL TK#SA002A002 HIGH PRODUCT ALARM ALARM 10-15-20 9:46AM T 1 TANK DIESEL TK#SA002U001 HIGH WATER WARNING CLEAR 10-15-20 9:15AM T 1 TANK DIESEL TK#SA002U001 HIGH PRODUCT ALARM CLEAR 10-15-20 9:13AM T 1 TANK DIESEL TK#SA002U001 HIGH PRODUCT ALARM ALARM 10-15-20 9:12AM T 1 TANK DIESEL TK#SA002U001 DELIVERY NEEDED CLEAR 10-15-20 9:11AM T 1 TANK DIESEL TK#SA002U001 HIGH WATER WARNING ALARM 10-15-20 8:33AM T 1 TANK DIESEL TK#SA002U001 DELIVERY NEEDED ALARM 10-15-20 8:29AM T 2 TANK DIESEL TK#SA002A002 HIGH PRODUCT ALARM CLEAR 10-23-19 10:30AM T 2 TANK DIESEL TK#SA002A002 HIGH PRODUCT ALARM ALARM 10-23-19 10:26AM T 2 TANK DIESEL TK#SA002A002 DELIVERY NEEDED CLEAR 10-23-19 10:26AM T 2 TANK DIESEL TK#SA002A002 INVALID FUEL LEVEL CLEAR 10-23-19 10:26AM T 2 TANK DIESEL TK#SA002A002 DELIVERY NEEDED ALARM 10-23-19 10:24AM T 2 TANK DIESEL TK#SA002A002 INVALID FUEL LEVEL ALARM 10-23-19 10:24AM T 1 TANK DIESEL TK#SA002U001 HIGH WATER WARNING CLEAR 10-23-19 9:16AM T 1 TANK DIESEL TK#SA002U001 HIGH PRODUCT ALARM CLEAR 10-23-19 9:16AM T 1 TANK DIESEL TK#SA002U001 HIGH PRODUCT ALARM ALARM 10-23-19 9:12AM T 1 TANK DIESEL TK#SA002U001 DELIVERY NEEDED CLEAR 10-23-19 9:11AM T 1 TANK DIESEL TK#SA002U001 HIGH WATER WARNING ALARM 10-23-19 9:04AM T 1 TANK DIESEL TK#SA002U001 DELIVERY NEEDED ALARM 10-23-19 9:01AM I20600 NOV 1, 2021 8:14 AM BKFDCA01 SA002 T-S 1520 20TH ST BAKERSFIELD,CA 93301 661-869-1846 TANK ALARM HISTORY TANK 1 DIESEL TK#SA002U001 LEAK ALARM OCT 11, 2011 6:08 AM OCT 14, 2010 2:44 PM OCT 13, 2010 11:06 AM HIGH WATER ALARM OCT 29, 2021 9:17 AM OCT 15, 2020 8:33 AM OCT 23, 2019 9:04 AM OVERFILL ALARM OCT 29, 2021 9:12 AM OCT 15, 2020 9:12 AM OCT 23, 2019 9:12 AM LOW PRODUCT ALARM OCT 29, 2021 9:10 AM OCT 15, 2020 8:29 AM OCT 23, 2019 9:01 AM SUDDEN LOSS ALARM APR 4, 2010 3:43 PM FEB 19, 2010 10:08 AM FEB 19, 2010 10:05 AM HIGH PRODUCT ALARM OCT 29, 2021 9:12 AM OCT 15, 2020 9:12 AM OCT 23, 2019 9:12 AM INVALID FUEL LEVEL AUG 8, 2017 6:13 AM PROBE OUT OCT 29, 2021 9:19 AM OCT 29, 2021 9:10 AM OCT 15, 2020 9:12 AM HIGH WATER WARNING OCT 29, 2021 9:17 AM OCT 15, 2020 8:33 AM OCT 23, 2019 9:04 AM DELIVERY NEEDED OCT 29, 2021 9:10 AM OCT 15, 2020 8:29 AM OCT 23, 2019 9:01 AM MAX PRODUCT ALARM OCT 15, 2020 9:12 AM OCT 23, 2019 9:13 AM NOV 2, 2018 9:26 AM CSLD INCR RATE WARN DEC 10, 2008 9:38 AM SEP 18, 2008 10:06 AM SEP 18, 2008 6:58 AM LOW TEMP WARNING JAN 22, 2013 9:53 AM APR 4, 2010 3:48 PM TANK 2 DIESEL TK#SA002A002 SETUP DATA WARNING JAN 27, 2012 11:49 AM HIGH WATER ALARM OCT 29, 2021 9:40 AM NOV 21, 2016 10:37 AM JAN 27, 2012 11:16 AM OVERFILL ALARM OCT 23, 2019 10:26 AM NOV 2, 2018 10:38 AM NOV 21, 2016 11:18 AM LOW PRODUCT ALARM OCT 23, 2019 10:24 AM NOV 21, 2016 10:31 AM JAN 7, 2014 9:54 AM SUDDEN LOSS ALARM OCT 12, 2010 8:39 PM FEB 19, 2010 9:55 AM APR 28, 2009 11:13 AM HIGH PRODUCT ALARM OCT 29, 2021 9:35 AM OCT 29, 2021 9:33 AM OCT 15, 2020 9:46 AM INVALID FUEL LEVEL OCT 29, 2021 9:33 AM OCT 23, 2019 10:24 AM NOV 21, 2016 10:31 AM PROBE OUT OCT 29, 2021 9:42 AM OCT 29, 2021 9:31 AM OCT 15, 2020 9:49 AM HIGH WATER WARNING OCT 29, 2021 9:40 AM NOV 21, 2016 10:37 AM JAN 27, 2012 11:16 AM DELIVERY NEEDED OCT 23, 2019 10:24 AM NOV 2, 2018 10:37 AM NOV 7, 2017 1:37 PM MAX PRODUCT ALARM OCT 29, 2021 9:35 AM OCT 29, 2021 9:33 AM OCT 15, 2020 9:46 AM LOW TEMP WARNING DEC 17, 2014 11:26 AM JAN 22, 2013 10:14 AM I30200 NOV 1, 2021 8:15 AM BKFDCA01 SA002 T-S 1520 20TH ST BAKERSFIELD,CA 93301 661-869-1846 LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 FILL SUMP OCT 29, 2021 8:49 AM FUEL ALARM MAY 21, 2021 9:15 AM FUEL ALARM OCT 15, 2020 9:04 AM FUEL ALARM 2 PIPING SUMP OCT 29, 2021 8:37 AM FUEL ALARM OCT 25, 2021 5:05 PM FUEL ALARM OCT 15, 2020 9:08 AM FUEL ALARM 3 DAYTANK RUPTURE BASN OCT 29, 2021 9:29 AM FUEL ALARM OCT 15, 2020 9:39 AM FUEL ALARM OCT 23, 2019 10:19 AM FUEL ALARM 4 DAY TANK ANNULAR OCT 29, 2021 9:27 AM FUEL ALARM OCT 15, 2020 9:35 AM FUEL ALARM OCT 23, 2019 10:16 AM FUEL ALARM 5 ANNULAR UST OCT 29, 2021 8:40 AM FUEL ALARM OCT 15, 2020 9:00 AM FUEL ALARM OCT 23, 2019 9:02 AM FUEL ALARM 6 TRANSITION SUMP OCT 29, 2021 9:01 AM FUEL ALARM OCT 15, 2020 9:17 AM FUEL ALARM OCT 23, 2019 9:24 AM FUEL ALARM 7 REMOTE PUMP CABINET OCT 29, 2021 8:57 AM FUEL ALARM OCT 15, 2020 9:19 AM FUEL ALARM OCT 23, 2019 9:28 AM FUEL ALARM Identification of Inspection Procedures for Overfill Prevention Equipment To Whom It May Concern: Tait Environmental Services, Inc., utilizes the following procedures when conducting Overfill Prevention Equipment Inspections: 1) Drop Tubes with Overfill Prevention Valves a) Verify information based upon Manufacturer installation instructions and follow their inspection procedures. b) If manufacturer information is not available, we conduct the inspection per PEI-RP1200-17, Section 7.1 2) Audible/Visual Alarms a) Verify programming or installation per manufacturer guidelines and test the system per manufacturer specifications. b) If manufacturer information is not available, we conduct the inspection per PEI-1200-17, Section 7.3. 3) Ballfloat Inspections are conducted following the procedures in PEI-RP1200-17, Section 7.2 Identification of Test Procedures for Secondary Containment Testing To Whom It May Concern: Tait Environmental Services, Inc., utilizes the following procedures when conducting Secondary Containment Testing: 1) Containment Sumps, Transition Sumps, UDCs – Tait follows PEI‐RP1200‐17 Section 6.6 for the accelerated test method. Tait uses the Incon TS‐1000 hydrostatic test equipment following the attached procedures. 2) Spill Buckets; Direct Bury & Contained in Sumps – Spill buckets contained in sumps are tested per PEI‐1200‐17, Section 6.2, however Tait Pass/Fail threshold is 0” drop in one hour. Direct Bury Spill Buckets are test the same as containment sumps per PEI‐1200‐17, Section 6.6. 3) Tank Annular Space – testing is conducted per PEI‐1200‐17, Section 4.2 4) Piping Secondary Containment – Testing is conducted per PEI‐RP1200‐17, Section 5.3 Please consider this letter as our Test Procedure utilized when conducting Secondary Containment Testing in lieu of either parts or the whole RP1200 document due to copyright infringement. California Environmental Reporting System: Business Jennifer Pruitt's Account Sign Out Tools Reports Help Submittal Finished: Submittal Finished: AT&T Corp. - SA002/CAK010/USID92203AT&T Corp. - SA002/CAK010/USID92203 Home »Draft Submittal »Submittal Finished (10029370) Print Submittal You have submitted the following elements on 11/18/2021 to Bakersfield City Fire Department • Underground Storage Tanks • Facility Information What's Next? • Return to the Draft Submittal page. • Return to Facility Home. Version 3.06.0001 | Enhancements | CERS Central Diagnostics | Conditions of Use | Privacy Policy | Contact | Help California Environmental Reporting System: Business | © 2021 California Environmental Protection AgencyCERS Technical Support: Request Technical Assistance Unified Program/General Assistance: Contact your local regulator(s) Home Home SubmittalsSubmittals FacilitiesFacilities ComplianceCompliance My BusinessMy Business CERS Help Settings My Business: AT&T Corp. Page 1 of 2Submittal Finish: CERS Business 11/18/2021https://cersbusiness2.calepa.ca.gov/43557/Facility/10029370/Submittal/2007013/Finish CERS Help Settings My Business: AT&T Corp. Page 2 of 2Submittal Finish: CERS Business 11/18/2021https://cersbusiness2.calepa.ca.gov/43557/Facility/10029370/Submittal/2007013/Finish