HomeMy WebLinkAbout2021-12-06 Riverlakes-FMC-PASSAppendix VI Underground Storage Tank  Monitoring System Certification Form CERS = California Environmental Reporting System, GPH = Gallons Per Hour, ID = Identification, ICC = International Code Council, LLD = Line Leak Detector, NA = Not Applicable, SW = Single- Walled, UDC = Under-Dispenser Containment, UST = Underground Storage Tank, VPH = Vacuum/Pressure/Hydrostatic Page 1 of 6 TYPE OF ACTION Installation Repair 12 Month 1. FACILITY INFORMATION CERS ID Certification Date Facility Name Facility Address City ZIP Code 2. SERVICE TECHNICIAN INFORMATION Company Performing the Certification Phone Mailing Address Service Technician Performing Test Contractor/Tank Tester License Number ICC Number ICC Expiration Date 3.TRAINING AND CERTIFICATIONS Manufacturer and Test Equipment Training Certifications Expiration Date 4.CERTIFICATION BY SERVICE TECHNICIAN CONDUCTING TEST I hereby certify that the monitoring system is operational in accordance with California Code of Regulations, title 23, division 3, chapter 16, section 2638; that required supporting documentation is attached; and all information contained herein is accurate. Service Technician Signature Date Total # of Pages Underground Storage Tank  Monitoring System Certification Form Page 2 of 6 5.MONITORING SYSTEM AND PROGRAMMING A separate Monitoring System Certification Form must be prepared for each control panel. Make of Monitoring System Control Panel Model of Monitoring System Control Panel Software Version Installed Attach the post-certification reports if the monitoring system is capable of generating either; Monitoring System Set-up Alarm History Report Yes No NA All monitoring equipment is operational per manufacturer’s specifications? Secondary containment systems are free of damage, debris, or liquid? Are the audible and visual alarms operational? All sensors have been: 1) visually inspected for wiring kinks, breaks and residual buildup on floats; and 2) tested for functionality and confirmed operational? Are all sensors installed to detect a release at the earliest opportunity in the secondary containment? The monitoring system set-up was reviewed, and proper settings confirmed? Was the monitoring control panel’s backup battery visually inspected, functionally tested, and confirmed operational? Does the flow of fuel stop at the dispenser if a release is detected in the under- dispenser containment? Does the turbine automatically shut down if the piping secondary containment monitoring system fails to operate or is electrically disconnected? Does the turbine automatically shut down if the piping secondary containment monitoring system detects a release? Which sensors initiate positive shut down? (Check all that apply) Sump UDC If monitoring system alarms are relayed to a remote monitoring center, is all communication equipment operational? Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 Underground Storage Tank  Monitoring System Certification Form Page 3 of 6 6. SENSOR TESTING RESULTS List only sensors tested on date of this certification. List “Sensor ID” as labeled in system programming. Additional copies of this page may be attached to accommodate all sensors tested. Sensor ID Sensor Model Component(s) Monitored Pass Fail Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 Underground Storage Tank  Monitoring System Certification Form Page 4 of 6 7. LINE LEAK DETECTOR TESTING Check this box if line leak detectors ARE NOT installed. (Do not complete this section.) Simulated release rate verified: (Check all that apply.) 3 GPH 0.1 GPH 0.2 GPH Yes No NA Has the testing apparatus been properly calibrated? For emergency generator tank systems, does the LLD create an audible and visual alarm when a leak is detected? For mechanical LLDs, does the LLD restrict the flow through the pipe when a release is detected? For electronic LLDs, does the turbine automatically shut off when a release is detected? For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system is disabled or disconnected? For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system malfunctions or fails a tightness test? For electronic LLDs, have all accessible wiring connections been visually inspected for kinks and breaks? Were all items on the equipment manufacturer’s maintenance checklist completed? Were all LLDs confirmed operational within regulatory requirements? LLD ID LLD Model Lines Monitored Pass Fail Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 Underground Storage Tank  Monitoring System Certification Form Page 5 of 6 8. IN-TANK GAUGING TESTING Check this box if tank gauging is used only for inventory control. Check this box if NO tank gauging equipment is installed. (Do not complete this section if either box is checked.) Yes No NA All wiring has been: 1) visually inspected for kinks, breaks and proper entry and termination; and 2) tested for ground faults? Were all in-tank gauging probes visually inspected for damage and residue buildup to ensure that floats move freely, functionally tested, and confirmed operational? Was accuracy of system’s product level readings tested? Was accuracy of system’s water level readings tested? Were all probes reinstalled properly? Were all items on the equipment manufacturer’s maintenance checklist completed? Probe ID Probe Model Tanks Monitored Pass Fail 9. COMMENTS Describe all answers marked “No” or “Fail” and proposed remedy. List all monitoring equipment either replaced or repaired. I20100 DEC 6, 2021 8:39 AM BROOKSIDE MARKET 4700 COFFEE RD BAKERSFIELD CA 93308 661-588-1338 IN-TANK INVENTORY TANK PRODUCT VOLUME TC VOLUME ULLAGE HEIGHT WATER TEMP 1 87 UNLEADED 6372 6339 15195 40.67 0.00 67.30 2 91 PREMIUM 5073 5037 3458 68.66 0.00 70.11 3 DIESEL 9240 9234 10711 56.35 0.00 73.87 > < I90500 DEC 6, 2021 8:39 AM SOFTWARE REVISION LEVEL VERSION 335.00 SOFTWARE# 346335-100-A CREATED - 18.08.27.10.22 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD/APM I50201 DEC 6, 2021 8:39 AM SHIFT TIME 1 : 1:00 AM I50202 DEC 6, 2021 8:39 AM SHIFT TIME 2 : DISABLED I50203 DEC 6, 2021 8:39 AM SHIFT TIME 3 : DISABLED I50204 DEC 6, 2021 8:39 AM SHIFT TIME 4 : DISABLED I54600 DEC 6, 2021 8:39 AM TANK PER TST NEEDED WRN: DISABLED I54900 DEC 6, 2021 8:39 AM TANK ANN TST NEEDED WRN: DISABLED I55300 DEC 6, 2021 8:39 AM LINE RE-ENABLE METHOD ALARM ACKNOWLEDGE I55600 DEC 6, 2021 8:39 AM LINE PER TST NEEDED WRN: DISABLED I55900 DEC 6, 2021 8:39 AM LINE ANN TST NEEDED WRN: DISABLED I51400 DEC 6, 2021 8:39 AM H-PROTOCOL DATA FORMAT HEIGHT I51A01 DEC 6, 2021 8:39 AM DAYLIGHT SAVING TIME ENABLED OFF I51B00 DEC 6, 2021 8:39 AM DAYLIGHT SAVING TIME START DATE MAR WEEK 2 SUN 2:00 AM END DATE NOV WEEK 1 SUN 2:00 AM I51600 DEC 6, 2021 8:39 AM RE-DIRECT LOCAL PRINTOUT DISABLED I50400 DEC 6, 2021 8:39 AM 232 SECURITY CODE PORT SECURITY CODE STATUS 1 000000 DISABLED 2 000000 DISABLED 3 000000 DISABLED 4 000000 DISABLED 5 000000 DISABLED 6 000000 DISABLED I21900 DEC 6, 2021 8:40 AM TANK CHART SECURITY DISABLED I5BD00 DEC 6, 2021 8:40 AM CUSTOM ALARM LABELS DISABLED I56000 DEC 6, 2021 8:40 AM MASS/DENSITY DISABLED I88101 DEC 6, 2021 8:40 AM PORT SETTINGS: COMM BOARD : 1 (RS-232) BAUD RATE : 9600 PARITY : ODD STOP BIT : 2 STOP DATA LENGTH: 7 DATA RS-232 SECURITY CODE : DISABLED I88102 DEC 6, 2021 8:40 AM PORT SETTINGS: COMM BOARD : 2 (S-SAT ) BAUD RATE : 9600 PARITY : NONE STOP BIT : 1 STOP DATA LENGTH: 8 DATA RS-232 SECURITY CODE : DISABLED I88103 DEC 6, 2021 8:40 AM PORT SETTINGS: COMM BOARD : 3 (EDIM ) RS-232 SECURITY CODE : DISABLED I60100 DEC 6, 2021 8:40 AM TANK CONFIGURATION DEVICE LABEL CONFIGURED 1 87 UNLEADED ON 2 91 PREMIUM ON 3 DIESEL ON 4 OFF I60200 DEC 6, 2021 8:40 AM TANK PRODUCT LABEL TANK PRODUCT LABEL 1 87 UNLEADED 2 91 PREMIUM 3 DIESEL 4 I60300 DEC 6, 2021 8:40 AM TANK PRODUCT CODE TANK PRODUCT LABEL 1 87 UNLEADED 1 2 91 PREMIUM 2 3 DIESEL 3 4 4 I60900 DEC 6, 2021 8:40 AM TANK THERMAL COEFFICIENT TANK PRODUCT LABEL 1 87 UNLEADED 0.000700 2 91 PREMIUM 0.000700 3 DIESEL 0.000045 4 0.000000 I60700 DEC 6, 2021 8:40 AM TANK DIAMETER TANK PRODUCT LABEL INCHES 1 87 UNLEADED 120.00 2 91 PREMIUM 120.00 3 DIESEL 120.00 4 0.00 I60A00 DEC 6, 2021 8:40 AM TANK FULL VOLUME TANK PRODUCT LABEL TANK PROFILE GALLONS 1 87 UNLEADED 4 PTS 21567 2 91 PREMIUM 4 PTS 8531 3 DIESEL 4 PTS 19951 4 1 PT 0 I60400 DEC 6, 2021 8:40 AM TANK FULL VOLUME TANK PRODUCT LABEL GALLONS 1 87 UNLEADED 21567 2 91 PREMIUM 8531 3 DIESEL 19951 4 0 I60500 DEC 6, 2021 8:40 AM TANK 4 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 87 UNLEADED 21567 17567 10858 4125 2 91 PREMIUM 8531 6888 4294 1692 3 DIESEL 19951 16262 10044 3804 4 0 0 0 0 I60600 DEC 6, 2021 8:40 AM TANK 20 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 87 UNLEADED 21567 0 0 0 0 17567 0 0 0 0 10858 0 0 0 0 4125 0 0 0 0 2 91 PREMIUM 8531 0 0 0 0 6888 0 0 0 0 4294 0 0 0 0 1692 0 0 0 0 3 DIESEL 19951 0 0 0 0 16262 0 0 0 0 10044 0 0 0 0 3804 0 0 0 0 4 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 I61500 DEC 6, 2021 8:40 AM TANK PRODUCT LABEL METER DATA 1 87 UNLEADED NO 2 91 PREMIUM NO 3 DIESEL NO 4 NO I62F00 DEC 6, 2021 8:40 AM MAG PROBE FLOAT SIZE TANK PRODUCT LABEL FLOAT SIZE: 1 87 UNLEADED 4.0 IN. 2 91 PREMIUM 2.0 IN. 3 DIESEL 4.0 IN. I62700 DEC 6, 2021 8:40 AM TANK HIGH WATER WARNING LIMIT TANK PRODUCT LABEL INCHES 1 87 UNLEADED 1.5 2 91 PREMIUM 1.5 3 DIESEL 1.5 I64200 DEC 6, 2021 8:40 AM WATER ALARM FILTER TANK PRODUCT LABEL 1 87 UNLEADED LOW 2 91 PREMIUM LOW 3 DIESEL LOW I62400 DEC 6, 2021 8:40 AM TANK HIGH WATER LEVEL LIMIT TANK PRODUCT LABEL INCHES 1 87 UNLEADED 2.0 2 91 PREMIUM 2.0 3 DIESEL 2.0 I62800 DEC 6, 2021 8:41 AM TANK MAXIMUM VOLUME LIMIT TANK PRODUCT LABEL GALLONS 1 87 UNLEADED 21567 2 91 PREMIUM 8531 3 DIESEL 19951 4 0 I62300 DEC 6, 2021 8:41 AM TANK OVERFILL LEVEL LIMIT TANK PRODUCT LABEL GALLONS 1 87 UNLEADED 19410 2 91 PREMIUM 7678 3 DIESEL 17956 4 0 I62200 DEC 6, 2021 8:41 AM TANK HIGH PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 87 UNLEADED 20489 2 91 PREMIUM 8104 3 DIESEL 18953 4 0 I62900 DEC 6, 2021 8:41 AM TANK DELIVERY REQUIRED LIMIT TANK PRODUCT LABEL GALLONS 1 87 UNLEADED 2157 2 91 PREMIUM 853 3 DIESEL 1995 4 0 I62100 DEC 6, 2021 8:41 AM TANK LOW PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 87 UNLEADED 1000 2 91 PREMIUM 500 3 DIESEL 1000 4 0 I62600 DEC 6, 2021 8:41 AM TANK LEAK ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 87 UNLEADED 99 2 91 PREMIUM 99 3 DIESEL 99 4 99 I62500 DEC 6, 2021 8:41 AM TANK SUDDEN LOSS LIMIT TANK PRODUCT LABEL GALLONS 1 87 UNLEADED 99 2 91 PREMIUM 99 3 DIESEL 99 4 99 I60800 DEC 6, 2021 8:41 AM TANK TILT TANK PRODUCT LABEL INCHES 1 87 UNLEADED 0.00 2 91 PREMIUM 0.00 3 DIESEL 0.00 4 0.00 I60B00 DEC 6, 2021 8:41 AM STICK HEIGHT OFFSET ENABLE STATUS DISABLED I60C00 DEC 6, 2021 8:41 AM TANK STICK HEIGHT OFFSET TANK PRODUCT LABEL INCHES 1 87 UNLEADED 0.00 2 91 PREMIUM 0.00 3 DIESEL 0.00 4 0.00 I61200 DEC 6, 2021 8:41 AM TANK MANIFOLDED PARTNERS TANK PRODUCT LABEL SIPHON MANIFOLDED TANKS LINE MANIFOLDED TANKS 1 87 UNLEADED NONE NONE 2 91 PREMIUM NONE NONE 3 DIESEL NONE NONE 4 NONE NONE I63600 DEC 6, 2021 8:41 AM PERIODIC LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 87 UNLEADED 0 2 91 PREMIUM 0 3 DIESEL 0 4 0 I62A00 DEC 6, 2021 8:41 AM ANNUAL LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 87 UNLEADED 0 2 91 PREMIUM 0 3 DIESEL 0 4 0 I62C00 DEC 6, 2021 8:41 AM TANK PERIODIC TEST TYPE TANK PRODUCT LABEL PERIODIC TEST TYPE 1 87 UNLEADED STANDARD 2 91 PREMIUM STANDARD 3 DIESEL STANDARD 4 STANDARD I62D00 DEC 6, 2021 8:41 AM TANK LEAK TEST FAIL ALARMS TANK PRODUCT LABEL 1 87 UNLEADED GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 2 91 PREMIUM GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 3 DIESEL GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 4 GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED I63100 DEC 6, 2021 8:41 AM TANK LEAK TEST AVERAGING TANK PRODUCT LABEL ANNUAL PERIODIC 1 87 UNLEADED OFF OFF 2 91 PREMIUM OFF OFF 3 DIESEL OFF OFF 4 OFF OFF I63000 DEC 6, 2021 8:41 AM IN-TANK LEAK TEST NOTIFY TANK PRODUCT LABEL TANK TEST NOTIFY: 1 87 UNLEADED OFF 2 91 PREMIUM OFF 3 DIESEL OFF 4 OFF I63200 DEC 6, 2021 8:42 AM TANK TEST SIPHON BREAK TANK PRODUCT LABEL SIPHON BREAK 1 87 UNLEADED OFF 2 91 PREMIUM OFF 3 DIESEL OFF 4 OFF I61000 DEC 6, 2021 8:42 AM TANK DELIVERY DELAY TANK PRODUCT LABEL 1 87 UNLEADED 5 2 91 PREMIUM 5 3 DIESEL 5 4 1 I63A00 DEC 6, 2021 8:42 AM LOW LEVEL PUMP THRESHOLD FOR SEQUENTIAL LINE MANIFOLD TANK PRODUCT LABEL PUMP THRESHOLD 1 87 UNLEADED 10.00% 2 91 PREMIUM 10.00% 3 DIESEL 10.00% 4 10.00% I61100 DEC 6, 2021 8:42 AM LEAK TEST METHOD - - - - - - - - - - - - TEST ON DATE : ALL TANK AUG 27, 2018 START TIME : DISABLED TEST RATE :0.20 GAL/HR DURATION : 2 HOURS TST EARLY STOP:DISABLED I61300 DEC 6, 2021 8:42 AM CSLD PROBABLITY OF DETECTION I61400 DEC 6, 2021 8:42 AM CSLD CLIMATE FACTOR I61600 DEC 6, 2021 8:42 AM TANK PRODUCT LABEL CAL UPDATE 1 87 UNLEADED IMMEDIATE 2 91 PREMIUM IMMEDIATE 3 DIESEL IMMEDIATE 4 IMMEDIATE I61A00 DEC 6, 2021 8:42 AM IN-TANK LEAK TEST EARLY STOP TANK PRODUCT LABEL TST EARLY STOP: 1 87 UNLEADED DISABLED 2 91 PREMIUM DISABLED 3 DIESEL DISABLED 4 DISABLED I61B00 DEC 6, 2021 8:42 AM IN-TANK LEAK GROSS TEST AUTO-CONFIRM I61C00 DEC 6, 2021 8:42 AM CSLD REPORT ONLY I63400 DEC 6, 2021 8:42 AM RECONCILIATION WARNING LIMIT TANK PRODUCT LABEL GALLONS 1 87 UNLEADED 0 2 91 PREMIUM 0 3 DIESEL 0 4 0 I63500 DEC 6, 2021 8:42 AM RECONCILIATION ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 87 UNLEADED 1 2 91 PREMIUM 1 3 DIESEL 1 4 1 I78700 DEC 6, 2021 8:42 AM I70200 DEC 6, 2021 8:42 AM LIQUID LABEL DEVICE LABEL 1 87 STP 2 87 FILL 3 91 STP 4 91 FILL 5 DIESEL STP 6 DIESEL FILL 7 UNLEADED ANNULAR 8 DIESEL ANNULAR 9 1-2 UDC 10 3-4 UDC 11 5-6 UDC 12 7-8 UDC 13 VENT BOX 14 15 16 I70300 DEC 6, 2021 8:42 AM LIQUID TYPE SENSOR LOCATION TYPE 1 87 STP DW SUMP 2-1 2 87 FILL DW SUMP 2-1 3 91 STP DW SUMP 2-1 4 91 FILL DW SUMP 2-1 5 DIESEL STP DW SUMP 2-1 6 DIESEL FILL DW SUMP 2-1 7 UNLEADED ANNULAR DUAL POINT HYDROSTATIC 8 DIESEL ANNULAR DUAL POINT HYDROSTATIC 9 1-2 UDC DW SUMP 2-1 10 3-4 UDC DW SUMP 2-1 11 5-6 UDC DW SUMP 2-1 12 7-8 UDC DW SUMP 2-1 13 VENT BOX DW SUMP 2-1 14 TRI-STATE (SINGLE FLOAT) 15 TRI-STATE (SINGLE FLOAT) 16 TRI-STATE (SINGLE FLOAT) I70400 DEC 6, 2021 8:42 AM LIQUID CATEGORY SENSOR LOCATION CATEGORY 1 87 STP STP SUMP 2 87 FILL PIPING SUMP 3 91 STP STP SUMP 4 91 FILL PIPING SUMP 5 DIESEL STP STP SUMP 6 DIESEL FILL PIPING SUMP 7 UNLEADED ANNULAR ANNULAR SPACE 8 DIESEL ANNULAR ANNULAR SPACE 9 1-2 UDC DISPENSER PAN 10 3-4 UDC DISPENSER PAN 11 5-6 UDC DISPENSER PAN 12 7-8 UDC DISPENSER PAN 13 VENT BOX OTHER SENSORS 14 OTHER SENSORS 15 OTHER SENSORS 16 OTHER SENSORS I80700 DEC 6, 2021 8:42 AM RELAY LABEL DEVICE LABEL 1 87 STP 2 91 STP 3 DIESEL STP 4 TEST 5 DISP 1-2 6 DISP 3-4 7 DISP 5-6 8 DISP 7-8 9 10 11 12 OVERFILL I80900 DEC 6, 2021 8:42 AM RELAY ORIENTATION RELAY DESIGNATION ORIENTATION 1 87 STP NORMALLY OPEN 2 91 STP NORMALLY OPEN 3 DIESEL STP NORMALLY OPEN 4 TEST NORMALLY OPEN 5 DISP 1-2 NORMALLY OPEN 6 DISP 3-4 NORMALLY OPEN 7 DISP 5-6 NORMALLY OPEN 8 DISP 7-8 NORMALLY OPEN 9 NORMALLY OPEN 10 NORMALLY OPEN 11 NORMALLY OPEN 12 OVERFILL NORMALLY OPEN I80B00 DEC 6, 2021 8:42 AM RELAY TANK ASSIGNMENT RELAY DESIGNATION TANK 1 87 STP 1 2 91 STP 2 3 DIESEL STP 3 4 TEST NONE 5 DISP 1-2 NONE 6 DISP 3-4 NONE 7 DISP 5-6 NONE 8 DISP 7-8 NONE 9 NONE 10 NONE 11 NONE 12 OVERFILL NONE I80A00 DEC 6, 2021 8:43 AM RELAY TYPE RELAY DESIGNATION TYPE 1 87 STP PUMP CONTROL OUTPUT 2 91 STP PUMP CONTROL OUTPUT 3 DIESEL STP PUMP CONTROL OUTPUT 4 TEST STANDARD 5 DISP 1-2 STANDARD 6 DISP 3-4 STANDARD 7 DISP 5-6 STANDARD 8 DISP 7-8 STANDARD 9 STANDARD 10 STANDARD 11 STANDARD 12 OVERFILL STANDARD I80800 DEC 6, 2021 8:43 AM RELAY SETUP REPORT R 1:87 STP TYPE: PUMP CONTROL OUTPUT TANK #: 1 IN-TANK ALARMS T 1:LOW PRODUCT ALARM LIQUID SENSOR ALMS L 1:FUEL ALARM L 9:FUEL ALARM L10:FUEL ALARM L11:FUEL ALARM L12:FUEL ALARM L 1:SENSOR OUT ALARM L 9:SENSOR OUT ALARM L10:SENSOR OUT ALARM L11:SENSOR OUT ALARM L12:SENSOR OUT ALARM L 1:SHORT ALARM L 9:SHORT ALARM L10:SHORT ALARM L11:SHORT ALARM L12:SHORT ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD HOSE ALARMS ALL:FLOW COLLECT FAIL R 2:91 STP TYPE: PUMP CONTROL OUTPUT TANK #: 2 IN-TANK ALARMS T 2:LOW PRODUCT ALARM LIQUID SENSOR ALMS L 3:FUEL ALARM L 9:FUEL ALARM L10:FUEL ALARM L11:FUEL ALARM L12:FUEL ALARM L 3:SENSOR OUT ALARM L 9:SENSOR OUT ALARM L10:SENSOR OUT ALARM L11:SENSOR OUT ALARM L12:SENSOR OUT ALARM L 3:SHORT ALARM L 9:SHORT ALARM L10:SHORT ALARM L11:SHORT ALARM L12:SHORT ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD HOSE ALARMS ALL:FLOW COLLECT FAIL R 3:DIESEL STP TYPE: PUMP CONTROL OUTPUT TANK #: 3 IN-TANK ALARMS T 3:LOW PRODUCT ALARM LIQUID SENSOR ALMS L 5:FUEL ALARM L 9:FUEL ALARM L10:FUEL ALARM L11:FUEL ALARM L12:FUEL ALARM L 5:SENSOR OUT ALARM L 9:SENSOR OUT ALARM L10:SENSOR OUT ALARM L11:SENSOR OUT ALARM L12:SENSOR OUT ALARM L 5:SHORT ALARM L 9:SHORT ALARM L10:SHORT ALARM L11:SHORT ALARM L12:SHORT ALARM R 4:TEST TYPE: STANDARD NORMALLY OPEN TANK #: NONE - NO ALARM ASSIGNMENTS - R 5:DISP 1-2 TYPE: STANDARD NORMALLY OPEN TANK #: NONE - NO ALARM ASSIGNMENTS - R 6:DISP 3-4 TYPE: STANDARD NORMALLY OPEN TANK #: NONE - NO ALARM ASSIGNMENTS - R 7:DISP 5-6 TYPE: STANDARD NORMALLY OPEN TANK #: NONE - NO ALARM ASSIGNMENTS - R 8:DISP 7-8 TYPE: STANDARD NORMALLY OPEN TANK #: NONE - NO ALARM ASSIGNMENTS - R 9: TYPE: STANDARD NORMALLY OPEN TANK #: NONE - NO ALARM ASSIGNMENTS - R10: TYPE: STANDARD NORMALLY OPEN TANK #: NONE - NO ALARM ASSIGNMENTS - R11: TYPE: STANDARD NORMALLY OPEN TANK #: NONE - NO ALARM ASSIGNMENTS - R12:OVERFILL TYPE: STANDARD NORMALLY OPEN TANK #: NONE IN-TANK ALARMS ALL:OVERFILL ALARM ALL:HIGH PRODUCT ALARM I79000 DEC 6, 2021 8:43 AM EDIM:1 VR:349643-001-B TD:97.10.27.11.25 I72300 DEC 6, 2021 8:43 AM BROOKSIDE MARKET 4700 COFFEE RD BAKERSFIELD CA 93308 661-588-1338 SMARTSENSOR ASSIGNMENT DEVICE LABEL CATEGORY 01 87 PRODUCT VAC SENSOR 02 UNKNOWN 03 VAPOR RETURN VAC SENSOR 04 91 PRODUCT VAC SENSOR 05 ALL VENTS VAC SENSOR 06 DIESEL PRODUCT VAC SENSOR 07 UNKNOWN 08 ATM ATM P SENSOR 09 1-2 FLOWMETER AIR FLOW METER 10 3-4 FLOWMETER AIR FLOW METER 11 5-6 FLOWMETER AIR FLOW METER 12 7-8 FLOWMETER AIR FLOW METER 13 UNKNOWN 14 UNKNOWN 15 UNKNOWN 16 PRESSURE SENSOR VAPOR PRESSURE IV4F00 DEC 6, 2021 8:43 AM BROOKSIDE MARKET 4700 COFFEE RD BAKERSFIELD CA 93308 661-588-1338 NOZZLE A/L RANGE A/L RATIO: 0.95 - 1.15 IV4000 DEC 6, 2021 8:43 AM BROOKSIDE MARKET 4700 COFFEE RD BAKERSFIELD CA 93308 661-588-1338 VAPOR PROCESSOR TYPE NONE IV4700 DEC 6, 2021 8:43 AM BROOKSIDE MARKET 4700 COFFEE RD BAKERSFIELD CA 93308 661-588-1338 ASSESSMENT TIME START TIME: 9:00 AM TIME DELAY MINUTES: 1 IV5200 DEC 6, 2021 8:43 AM BROOKSIDE MARKET 4700 COFFEE RD BAKERSFIELD CA 93308 661-588-1338 ACCEPT HIGH ORVR: NO IV4A00 DEC 6, 2021 8:43 AM BROOKSIDE MARKET 4700 COFFEE RD BAKERSFIELD CA 93308 661-588-1338 ISD HOSE TABLE HOSE FP FP AFM REL HOSE ID ID LABEL ID ID LABEL 01 01 01 01 02 BLEND3 02 02 02 01 02 BLEND3 03 03 03 02 02 BLEND3 04 04 04 02 02 BLEND3 05 05 05 03 02 BLEND3 06 06 06 03 02 BLEND3 07 07 07 04 02 BLEND3 08 08 08 04 02 BLEND3 IV4B00 DEC 6, 2021 8:43 AM BROOKSIDE MARKET 4700 COFFEE RD BAKERSFIELD CA 93308 661-588-1338 PRODUCT/HOSE MAP TABLE FP AFID M1/H1 M2/H2 M3/H3 M4/H4 01 01 xx/xx 02/01 01/01 xx/xx 02 01 02/02 xx/xx 09/02 01/02 03 02 02/03 09/03 01/03 xx/xx 04 02 02/04 01/04 09/04 xx/xx 05 03 02/05 01/05 09/05 xx/xx 06 03 02/06 09/06 01/06 xx/xx 07 04 02/07 01/07 09/07 xx/xx 08 04 02/08 01/08 xx/xx 09/08 IV4900 DEC 6, 2021 8:44 AM BROOKSIDE MARKET 4700 COFFEE RD BAKERSFIELD CA 93308 661-588-1338 LABEL TABLE ID LABEL 01 UNASSIGNED 02 BLEND3 03 REGULAR 04 MID GRADE 05 PREMIUM 06 GOLD 07 BRONZE 08 SILVER 09 BLEND2 10 BLEND4 IV1000 DEC 6, 2021 8:44 AM ISD VERSION: 01.05 I90200 DEC 6, 2021 8:44 AM SOFTWARE REVISION LEVEL VERSION 335.00 SOFTWARE# 346335-100-A CREATED - 18.08.27.10.22 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD/APM I11100 DEC 6, 2021 8:44 AM BROOKSIDE MARKET 4700 COFFEE RD BAKERSFIELD CA 93308 661-588-1338 PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME E 1 OTHER COMMUNICATION ALARM CLEAR 12-06-21 2:05AM E 1 OTHER COMMUNICATION ALARM ALARM 12-06-21 2:04AM E 1 OTHER COMMUNICATION ALARM CLEAR 11-29-21 2:09AM E 1 OTHER COMMUNICATION ALARM ALARM 11-29-21 2:08AM E 1 OTHER COMMUNICATION ALARM CLEAR 11-27-21 6:55PM E 1 OTHER COMMUNICATION ALARM ALARM 11-27-21 6:54PM E 1 OTHER COMMUNICATION ALARM CLEAR 11-24-21 3:54PM E 1 OTHER COMMUNICATION ALARM ALARM 11-24-21 3:53PM E 1 OTHER COMMUNICATION ALARM CLEAR 11-22-21 2:10AM E 1 OTHER COMMUNICATION ALARM ALARM 11-22-21 2:08AM E 1 OTHER COMMUNICATION ALARM CLEAR 11-15-21 2:09AM E 1 OTHER COMMUNICATION ALARM ALARM 11-15-21 2:08AM E 1 OTHER COMMUNICATION ALARM CLEAR 11-08-21 2:10AM E 1 OTHER COMMUNICATION ALARM ALARM 11-08-21 2:09AM E 1 OTHER COMMUNICATION ALARM CLEAR 11-01-21 2:09AM E 1 OTHER COMMUNICATION ALARM ALARM 11-01-21 2:08AM L12 DISP PAN 7-8 UDC LOW LIQUID ALARM CLEAR 10-26-21 11:35AM L 2 PIPE 87 FILL FUEL ALARM CLEAR 10-26-21 11:13AM L12 DISP PAN 7-8 UDC LOW LIQUID ALARM ALARM 10-26-21 3:27AM L 2 PIPE 87 FILL FUEL ALARM ALARM 10-25-21 12:25PM E 1 OTHER COMMUNICATION ALARM CLEAR 10-25-21 2:12AM E 1 OTHER COMMUNICATION ALARM ALARM 10-25-21 2:11AM E 1 OTHER COMMUNICATION ALARM CLEAR 10-18-21 2:10AM E 1 OTHER COMMUNICATION ALARM ALARM 10-18-21 2:09AM L11 DISP PAN 5-6 UDC LOW LIQUID ALARM CLEAR 10-14-21 10:18AM L11 DISP PAN 5-6 UDC LOW LIQUID ALARM ALARM 10-14-21 6:47AM L11 DISP PAN 5-6 UDC LOW LIQUID ALARM CLEAR 10-13-21 12:06PM L11 DISP PAN 5-6 UDC LOW LIQUID ALARM ALARM 10-13-21 6:02AM E 1 OTHER COMMUNICATION ALARM CLEAR 10-11-21 2:10AM E 1 OTHER COMMUNICATION ALARM ALARM 10-11-21 2:09AM T 3 TANK DIESEL LOW PRODUCT ALARM CLEAR 10-07-21 6:45PM T 3 TANK DIESEL LOW PRODUCT ALARM ALARM 10-07-21 6:38PM E 1 OTHER COMMUNICATION ALARM CLEAR 10-04-21 4:59PM E 1 OTHER COMMUNICATION ALARM ALARM 10-04-21 4:58PM E 1 OTHER COMMUNICATION ALARM CLEAR 9-27-21 2:10AM E 1 OTHER COMMUNICATION ALARM ALARM 9-27-21 2:09AM E 1 OTHER COMMUNICATION ALARM CLEAR 9-24-21 10:20AM E 1 OTHER COMMUNICATION ALARM ALARM 9-24-21 10:18AM E 1 OTHER COMMUNICATION ALARM CLEAR 9-20-21 2:10AM E 1 OTHER COMMUNICATION ALARM ALARM 9-20-21 2:09AM E 1 OTHER COMMUNICATION ALARM CLEAR 9-13-21 2:10AM E 1 OTHER COMMUNICATION ALARM ALARM 9-13-21 2:08AM E 1 OTHER COMMUNICATION ALARM CLEAR 9-06-21 2:05AM E 1 OTHER COMMUNICATION ALARM ALARM 9-06-21 2:04AM E 1 OTHER COMMUNICATION ALARM CLEAR 8-30-21 2:09AM E 1 OTHER COMMUNICATION ALARM ALARM 8-30-21 2:08AM E 1 OTHER COMMUNICATION ALARM CLEAR 8-23-21 2:08AM E 1 OTHER COMMUNICATION ALARM ALARM 8-23-21 2:07AM T 2 TANK 91 PREMIUM OVERFILL ALARM CLEAR 8-18-21 9:32AM T 2 TANK 91 PREMIUM OVERFILL ALARM ALARM 8-18-21 9:23AM I11200 DEC 6, 2021 8:44 AM BROOKSIDE MARKET 4700 COFFEE RD BAKERSFIELD CA 93308 661-588-1338 NON-PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME SYSTEM PRINTER ERROR CLEAR 11-29-21 5:46AM SYSTEM PAPER OUT CLEAR 11-29-21 5:46AM SYSTEM PRINTER ERROR ALARM 11-29-21 5:40AM SYSTEM PAPER OUT ALARM 11-29-21 5:40AM T 3 TANK DIESEL DELIVERY NEEDED CLEAR 11-19-21 12:11PM T 3 TANK DIESEL DELIVERY NEEDED ALARM 11-19-21 8:05AM T 3 TANK DIESEL DELIVERY NEEDED CLEAR 10-07-21 6:48PM T 3 TANK DIESEL DELIVERY NEEDED ALARM 10-06-21 6:48AM T 3 TANK DIESEL DELIVERY NEEDED CLEAR 9-30-21 8:40AM T 3 TANK DIESEL DELIVERY NEEDED ALARM 9-28-21 3:15PM OTHER ISD VAPOR LEAK WARN CLEAR 9-13-21 9:03AM SYSTEM PRINTER ERROR CLEAR 9-08-21 9:19AM SYSTEM PAPER OUT CLEAR 9-08-21 9:19AM SYSTEM PRINTER ERROR ALARM 9-08-21 9:18AM SYSTEM PAPER OUT ALARM 9-08-21 9:18AM OTHER ISD VAPOR LEAK WARN ALARM 9-08-21 9:04AM SYSTEM PRINTER ERROR CLEAR 9-01-21 10:26AM SYSTEM PAPER OUT CLEAR 9-01-21 10:26AM SYSTEM PRINTER ERROR ALARM 9-01-21 10:26AM SYSTEM PAPER OUT ALARM 9-01-21 10:26AM SYSTEM PAPER OUT CLEAR 9-01-21 10:24AM SYSTEM PAPER OUT ALARM 9-01-21 10:23AM T 3 TANK DIESEL DELIVERY NEEDED CLEAR 7-16-21 5:39AM T 3 TANK DIESEL DELIVERY NEEDED ALARM 7-15-21 4:16AM T 3 TANK DIESEL DELIVERY NEEDED CLEAR 6-30-21 9:13AM T 3 TANK DIESEL DELIVERY NEEDED ALARM 6-30-21 7:20AM SYSTEM PAPER OUT CLEAR 6-28-21 10:24AM SYSTEM PRINTER ERROR CLEAR 6-28-21 10:23AM SYSTEM PRINTER ERROR ALARM 6-28-21 10:23AM SYSTEM PAPER OUT ALARM 6-28-21 10:21AM SYSTEM PRINTER ERROR CLEAR 5-05-21 5:17AM SYSTEM PRINTER ERROR ALARM 5-05-21 5:17AM SYSTEM PRINTER ERROR CLEAR 5-04-21 9:32AM SYSTEM PRINTER ERROR ALARM 5-04-21 9:32AM SYSTEM PAPER OUT CLEAR 5-04-21 9:32AM SYSTEM PAPER OUT ALARM 5-04-21 9:32AM SYSTEM PRINTER ERROR CLEAR 5-04-21 9:32AM SYSTEM PRINTER ERROR ALARM 5-04-21 9:32AM SYSTEM PRINTER ERROR CLEAR 5-04-21 6:01AM SYSTEM PRINTER ERROR ALARM 5-04-21 6:01AM SYSTEM PAPER OUT CLEAR 4-22-21 7:44AM SYSTEM PAPER OUT ALARM 4-22-21 7:44AM T 3 TANK DIESEL DELIVERY NEEDED CLEAR 4-09-21 3:27PM T 3 TANK DIESEL DELIVERY NEEDED ALARM 4-09-21 7:40AM T 3 TANK DIESEL DELIVERY NEEDED CLEAR 3-25-21 5:54AM T 3 TANK DIESEL DELIVERY NEEDED ALARM 3-24-21 9:02AM SYSTEM PAPER OUT CLEAR 3-18-21 7:46AM SYSTEM PAPER OUT ALARM 3-18-21 7:46AM SYSTEM PRINTER ERROR CLEAR 3-09-21 8:25AM SYSTEM PRINTER ERROR ALARM 3-09-21 8:25AM I20600 DEC 6, 2021 8:44 AM BROOKSIDE MARKET 4700 COFFEE RD BAKERSFIELD CA 93308 661-588-1338 TANK ALARM HISTORY TANK 1 87 UNLEADED SETUP DATA WARNING OCT 9, 2019 2:20 PM HIGH WATER ALARM OCT 10, 2019 7:39 AM OVERFILL ALARM NOV 17, 2020 11:29 AM OCT 10, 2019 11:45 AM LOW PRODUCT ALARM OCT 10, 2019 7:35 AM OCT 9, 2019 2:18 PM HIGH PRODUCT ALARM NOV 17, 2020 11:29 AM OCT 10, 2019 11:54 AM PROBE OUT NOV 17, 2020 11:57 AM NOV 17, 2020 11:23 AM OCT 10, 2019 12:21 PM HIGH WATER WARNING OCT 10, 2019 7:39 AM DELIVERY NEEDED OCT 10, 2019 7:35 AM OCT 9, 2019 2:18 PM MAX PRODUCT ALARM NOV 17, 2020 11:30 AM LOW TEMP WARNING NOV 17, 2020 11:58 AM OCT 10, 2019 12:22 PM TANK 2 91 PREMIUM SETUP DATA WARNING OCT 9, 2019 2:20 PM HIGH WATER ALARM NOV 17, 2020 11:52 AM OCT 9, 2019 3:09 PM OCT 9, 2019 2:24 PM OVERFILL ALARM AUG 18, 2021 9:23 AM AUG 16, 2021 8:24 AM MAR 30, 2021 10:32 AM LOW PRODUCT ALARM NOV 17, 2020 11:22 AM OCT 9, 2019 2:40 PM SUDDEN LOSS ALARM NOV 17, 2020 11:23 AM HIGH PRODUCT ALARM NOV 17, 2020 11:49 AM OCT 9, 2019 2:18 PM PROBE OUT NOV 17, 2020 11:57 AM NOV 17, 2020 11:55 AM NOV 17, 2020 11:23 AM HIGH WATER WARNING NOV 17, 2020 11:52 AM OCT 9, 2019 3:09 PM OCT 9, 2019 2:24 PM DELIVERY NEEDED NOV 17, 2020 11:22 AM OCT 9, 2019 2:40 PM MAX PRODUCT ALARM NOV 17, 2020 11:49 AM OCT 9, 2019 2:18 PM LOW TEMP WARNING NOV 17, 2020 12:12 PM TANK 3 DIESEL SETUP DATA WARNING AUG 27, 2018 8:19 AM HIGH WATER ALARM OCT 10, 2019 8:36 AM OCT 10, 2019 7:37 AM OVERFILL ALARM NOV 17, 2020 11:27 AM OCT 10, 2019 11:41 AM OCT 10, 2019 8:33 AM LOW PRODUCT ALARM OCT 7, 2021 6:38 PM OCT 10, 2019 7:33 AM AUG 27, 2018 8:05 AM HIGH PRODUCT ALARM OCT 10, 2019 11:41 AM OCT 10, 2019 7:52 AM INVALID FUEL LEVEL AUG 27, 2018 8:05 AM PROBE OUT NOV 17, 2020 11:56 AM NOV 17, 2020 11:21 AM OCT 10, 2019 12:20 PM HIGH WATER WARNING OCT 10, 2019 7:56 AM OCT 10, 2019 7:37 AM DELIVERY NEEDED NOV 19, 2021 8:05 AM OCT 6, 2021 6:48 AM SEP 28, 2021 3:15 PM LOW TEMP WARNING OCT 10, 2019 12:21 PM I30200 DEC 6, 2021 8:44 AM BROOKSIDE MARKET 4700 COFFEE RD BAKERSFIELD CA 93308 661-588-1338 LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 87 STP NOV 17, 2020 11:34 AM SENSOR OUT ALARM NOV 17, 2020 10:43 AM FUEL ALARM NOV 17, 2020 10:19 AM LOW LIQUID ALARM 2 87 FILL OCT 25, 2021 12:25 PM FUEL ALARM APR 25, 2021 10:42 PM FUEL ALARM JAN 28, 2021 7:05 PM FUEL ALARM 3 91 STP NOV 17, 2020 11:34 AM SENSOR OUT ALARM NOV 17, 2020 10:44 AM FUEL ALARM NOV 17, 2020 10:20 AM LOW LIQUID ALARM 4 91 FILL FEB 16, 2021 9:03 AM LOW LIQUID ALARM NOV 17, 2020 11:34 AM SENSOR OUT ALARM NOV 17, 2020 10:49 AM FUEL ALARM 5 DIESEL STP NOV 17, 2020 12:23 PM LOW LIQUID ALARM NOV 17, 2020 12:23 PM LOW LIQUID ALARM NOV 17, 2020 11:34 AM SENSOR OUT ALARM 6 DIESEL FILL NOV 17, 2020 11:34 AM SENSOR OUT ALARM NOV 17, 2020 10:49 AM FUEL ALARM NOV 17, 2020 10:20 AM LOW LIQUID ALARM 7 UNLEADED ANNULAR NOV 17, 2020 11:54 AM LOW LIQUID ALARM NOV 17, 2020 11:54 AM HIGH LIQUID ALARM NOV 17, 2020 11:53 AM LOW LIQUID ALARM 8 DIESEL ANNULAR NOV 17, 2020 11:54 AM HIGH LIQUID ALARM NOV 17, 2020 11:54 AM LOW LIQUID ALARM NOV 17, 2020 11:34 AM SENSOR OUT ALARM 9 1-2 UDC NOV 17, 2020 11:34 AM SENSOR OUT ALARM NOV 17, 2020 10:29 AM FUEL ALARM NOV 17, 2020 10:21 AM LOW LIQUID ALARM 10 3-4 UDC JAN 26, 2021 6:45 AM LOW LIQUID ALARM NOV 17, 2020 11:34 AM SENSOR OUT ALARM NOV 17, 2020 10:33 AM FUEL ALARM 11 5-6 UDC OCT 14, 2021 6:47 AM LOW LIQUID ALARM OCT 13, 2021 6:02 AM LOW LIQUID ALARM NOV 17, 2020 11:34 AM SENSOR OUT ALARM 12 7-8 UDC OCT 26, 2021 3:27 AM LOW LIQUID ALARM NOV 17, 2020 11:34 AM SENSOR OUT ALARM NOV 17, 2020 10:39 AM FUEL ALARM 13 VENT BOX NOV 17, 2020 11:34 AM SENSOR OUT ALARM NOV 17, 2020 10:49 AM FUEL ALARM NOV 17, 2020 10:20 AM LOW LIQUID ALARM I31600 DEC 6, 2021 8:44 AM BROOKSIDE MARKET 4700 COFFEE RD BAKERSFIELD CA 93308 661-588-1338 SMART SENSOR ALARM HISTORY REPORT SENSOR LOCATION 1 87 PRODUCT NOV 17, 2020 11:11 AM HIGH LIQUID ALARM NOV 17, 2020 11:10 AM NO VACUUM ALARM OCT 10, 2019 12:06 PM HIGH LIQUID ALARM 3 VAPOR RETURN MAR 10, 2021 3:31 PM SENSOR FAULT ALARM NOV 17, 2020 11:17 AM HIGH LIQUID ALARM NOV 17, 2020 11:17 AM NO VACUUM ALARM 4 91 PRODUCT FEB 10, 2021 11:28 AM NO VACUUM ALARM FEB 10, 2021 11:13 AM NO VACUUM ALARM NOV 17, 2020 11:06 AM HIGH LIQUID ALARM 5 ALL VENTS MAR 2, 2021 8:46 AM HIGH LIQUID ALARM MAR 2, 2021 8:45 AM NO VACUUM ALARM FEB 10, 2021 11:26 AM COMMUNICATION ALARM 6 DIESEL PRODUCT NOV 17, 2020 11:19 AM HIGH LIQUID ALARM NOV 17, 2020 11:19 AM NO VACUUM ALARM OCT 10, 2019 12:07 PM HIGH LIQUID ALARM 8 ATM 9 1-2 FLOWMETER AUG 27, 2018 9:34 AM COMMUNICATION ALARM 10 3-4 FLOWMETER AUG 27, 2018 9:34 AM COMMUNICATION ALARM 11 5-6 FLOWMETER AUG 27, 2018 9:34 AM COMMUNICATION ALARM 12 7-8 FLOWMETER AUG 27, 2018 9:34 AM COMMUNICATION ALARM 16 PRESSURE SENSOR AUG 27, 2018 9:34 AM COMMUNICATION ALARM I10200 DEC 6, 2021 8:44 AM BROOKSIDE MARKET 4700 COFFEE RD BAKERSFIELD CA 93308 661-588-1338 SYSTEM CONFIGURATION SLOT BOARD TYPE POWER ON RESET CURRENT 1 UNUSED 4952047 4931968 2 UNUSED 4939418 4924323 3 4 PROBE / G.T. 165562 165535 4 INTERSTITIAL BD 204254 204085 5 INTERSTITIAL BD 204109 204280 6 7SMARTSENSOR BD 516304 516038 7 8SMARTSENSOR BD 39981 39977 8 UNUSED 4932980 4926296 9 RELAY BOARD 15141 15150 10 RELAY BOARD 15141 15150 11 RELAY BOARD 15163 15172 12 STP SENSE BOARD 33612 33557 13 UNUSED 4942637 4923327 14 UNUSED 4938220 4920928 15 UNUSED 4936444 4921018 16 UNUSED 4938753 4920704 COMM 1 RS232 SERIAL BD 15186 15172 COMM 2 SERIAL SAT BD 488306 488261 COMM 3 ELEC DISP INT. 102294 102446 COMM 4 UNUSED 4940528 4930815 COMM 5 UNUSED 84872 4933640 COMM 6 RS232 SERIAL BD 15208 15195 I90200 DEC 6, 2021 8:45 AM SOFTWARE REVISION LEVEL VERSION 335.00 SOFTWARE# 346335-100-A CREATED - 18.08.27.10.22 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD/APM UDC-1UDC-2 U D C - 3 U D C - 4 1234 5 6 7 8 Diesel 91 Premium 87 Unleaded 22,000 GALLONS UST-1 8 , 0 0 0 G A L L O N S U S T - 2 20,000 GALLONS UST-3 TS-3 TS-1TS-2 FS-1 F S - 2 FS-3 AA V VVV DISPENSER U D C 1 - 2 536 SENSO R D I S P E N S E R U D C 3 - 4 5 3 6 S E N S O R D I S P E N S E R U D C 5 - 6 5 3 6 S E N S O R D I S P E N S E R U D C 7 - 8 5 3 6 S E N S O R 87 TURBINE SUMP536 SENSOR480 SENSOR99LD LINE LEAK DETECTORVACUUM SENSOR KIT #11-2-3-4-5-6-7-8 PRODUCT LINEDIESEL TURBINE SUMP536 SENSOR480 SENSOR99LD LINE LEAK DETECTORVACUUM SENSOR KIT #31-2-7-8 PRODUCT LINE91 TURBINE SUMP536 SENSOR480 SENSOR99LD LINE LEAK DETECTORVACUUM SENSOR KIT #21-2-3-4-5-6-7-8 PRODUCT LINE87 FILL SUMP536 SENSORDIESEL FILL SUMP536 SENSOR P R E M I U M F I L L S U M P 5 3 6 S E N S O R DIESEL ANNULAR303 SENSOR 8 7 9 1 A N N U L A R 3 0 3 S E N S O R HEALY CLE A N A I R S E P E R A T O R V E N T S U M P T R A N S I T I O N S U M P 5 3 6 S E N S O R ZONE # 1-87 REGULARZONE#4- 91 PREMIUM ZONE #2- 87 VAPOR LINE Z O N E # 3 - 8 7 V E N T L I N E Z O N E # 7 - D I E S E L V E N T L I N E Z O N E # 5 - 9 1 V E N T L I N E SLOPE 18" P E R F O O T M I N . T O T A N K S S T O R E E L E C T R I C A L T I E I N FIRE HYDRANT E S T O P T L S H A G E M A N R D COFFEE RD30K SPLIT TANK L E G E N D V A C U U M S E N S O R K I T # 1 - 8 7 T U R B I N E Z O N E 1 8 7 B R U G G P R O D U C T Z O N E 2 8 7 V A P O R L I N E Z O N E 3 8 7 V E N T L I N E V A C U U M S E N S O R K I T # 2 - 9 1 T U R B I N E Z O N E 4 9 1 B R U G G P R O D U C T Z O N E 5 9 1 V E N T L I N E V A C U U M S E N S O R K I T # 3 - D I E S E L T U R B I N E Z O N E 6 D I E S E L B R U G G P R O D U C T Z O N E 7 D I E S E L V E N T L I N E V E E D E R R O O T S E N S O R , P R O B E S , L E A K D E T E C T O R S 4 D I S P E N S E R + U D C U D C 1 , 2 , 3 , 4 3 3 0 0 2 0 - 5 3 6 H Y D R O S T A T I C D I S P E N S E R P A N S E N S O R 2 A N N U L A R S 3 0 K S P L I T + 2 0 K 3 3 0 0 2 0 - 5 3 6 H Y D R O S T A T I C D I S P E N S E R P A N S E N S O R 7 9 4 3 8 0 - 3 0 3 B R I N E S E N S O R 3 T U R B I N E S U M P S 8 7 , 9 1 , D I E S E L P R O D U C T S 3 3 0 0 2 0 - 5 3 6 H Y D R O S T A T I C D I S P E N S E R P A N S E N S O R 3 3 0 0 2 0 - 4 8 0 V A C U U M S E N S O R 1 1 6 - 0 5 7 - 5 L I N E L E A K D E T E C T O R 3 F I L L S U M P S 8 7 , 9 1 , D I E S E L 3 3 0 0 2 0 - 5 3 6 H Y D R O S T A T I C D I S P E N S E R P A N S E N S O R 1 V E N T S U M P H E A L Y T A N K 3 3 0 0 2 0 - 5 3 6 H Y D R O S T A T I C D I S P E N S E R P A N S E N S O R 3 T A N K P R O B E S 8 7 , 9 1 , D I E S E L 8 4 6 3 9 0 - 1 1 0 M A G P R O B E 3 L E A K D E T E C T O R S 8 7 , 9 1 , D I E S E L 9 9 L D - 2 0 0 0 V M I L I N E L E A K D E T E C T O R 6 " X 7 F O O T B O L L A R D S H B P R O P A N E T A N K SITE MAP = P e n e t r a t i o n s B R A V O F - 7 5 - P E - B R G - D ( 6 5 ) F O R P R O D U C T = P e n e t r a t i o n s B R A V O F - 3 2 - T S - D B R A V O F B ( 5 1 ) F O R V A P O R / V E N T NORTHZONE# 6- DIESELPRICE SIGN AIR /WATER S I T E H A Z M A T I N V E N T O R Y C A R B O N D I O X I D E L I Q U I D A B S O R B A N T P A D S C I M - T E K F I L T E R S L I Q U E F I E D P E T R O L E U M G A S ( L P G ) G A S O L I N E A L L G R A D E S D I E S E L F U E L N O . 2 C O 2 C O 2 F I R E S U P R E S S I O N C I R C U I T B R E A K E R WATER METER SHUTOFF O V E R F I L L A L A R M C I M - T E K F I L T E R S O U T S I D E A B S O R B A N T P A D S O U T S I D E