Loading...
HomeMy WebLinkAboutFMC 2021IMPACT VALVE LEAK DETECTOR LINE TEST MONITOR CERTIFICATION SPILL BUCKET TEST 11000 N. MoPac Expressway, Suite 500 Austin, Texas 78759 Phone: (512) 451-6334 Fax: (512) 459-1459 Date Printed and Mailed: 10/21/2021 BAKERSFIELD FIRE DEPARTMENT OFFICE OF ENVIRONMENTAL SERVICES INSPECTOR KRIS KARNS 1501 TRUXTUN AVE. BAKERSFIELD, CA 93301 Test Date: 10/19/2021 Order Number: 3452695 Dear Regulator, Enclosed are the results of recent testing performed at the following facility: SAM'S CLUB # 4819 (SC4819) 5625 GOSFORD ROAD BAKERSFIELD, CA 93313 In an effort to keep all our record keeping and reporting requirements as current as possible, Tanknology kindly requests you notify Dawn Kohlmeyer in writing at dkohlmeyer@tanknology.com when your CUPA requires all records to be submitted electronically via the CERS database. Your assistance in this endeavor is greatly appreciated. Testing performed: Sincerely, Dawn Kohlmeyer Manager, Field Reporting Product Line Tightness Test Page 1 of 1 Work Order: 3452695 Date: 10/19/2021 Site Name/ID: SAM'S CLUB # 4819 / SC4819 Address: 5625 GOSFORD ROAD City: BAKERSFIELD State: CA Zip: 93313 Tank Information Test Method Customer Tank ID Product Name Delivery Type Test Pressure (psi) Test Start Time Test End Time Final Leak Rate (gph) Test Result(P/F/I) Test was performed per 3rd party certifications as specified in 40 CFR parts 280 and 281 Tank # 1 Line # 1 TLD-1 1 UNLEADED Pressure 50 11:28 11:58 0.00 Pass Yes Tank # 2 Line # 1 TLD-1 2 UNLEADED Pressure 50 11:28 11:58 0.00 Pass Yes Tank # 3 Line # 1 TLD-1 3 PREMIUM Pressure 50 11:28 11:58 0.00 Pass Yes Tank # 4 Line # 1 TLD-1 4 DIESEL2 Pressure 50 11:28 11:58 0.00 Pass Yes Tank # Line # Tank # Line # Technician Comments: Technician Name:Patrick Pfrang Certification #:44642 exp: 4/6/2022 Technician Signature: Environmental Compliance for Petroleum Systems ©2021 Tanknology Inc., Austin, TX. All rights reserved. tanknology.com LDT 5000 Field Test Apparatus Line Leak Detector Test Page 1 of 1 Work Order:3452695 Date:10/19/2021 Site Name / ID:SAM'S CLUB # 4819 / SC4819 Address:5625 GOSFORD ROAD City:BAKERSFIELD State:CA Zip:93313 Tank ID Product Product Line Tested From Existing/New Mechanical/Electronic Manufacturer/Model Serial No. Pump Operating Pressure (psi) Calibrated Leak (ml/min) Calibrated Leak (gph) Holding PSI *N/A for Electronic LD's Resiliency (ml) *N/A for Electronic LD's Metering PSI *N/A for Electronic LD's Opening Time (sec) *N/A for Electronic LD's Test Results 1 UNLEADED 1 8 Existing Mechanical Red Jacket FX1V 307098751 40.00 189.0 3.00 40.00 140.00 12 3 Pass 2 UNLEADED 1 16 Existing Mechanical Red Jacket FX1V 307098752 39.00 189.0 3.00 20.00 175.00 12 3 Pass 3 PREMIUM 1 8 Existing Mechanical Red Jacket FX1V 104192098 40.00 189.0 3.00 20.00 150.00 11 5 Pass 4 DIESEL2 1 8 Existing Mechanical Red Jacket FX1DV 111136174 30.00 189.0 3.00 20.00 110.00 10 7 Pass Technician Comments: Technician Name:Patrick Pfrang Certification #:44637 Technician Signature:Expire Date:4/6/2022 Environmental Compliance for Petroleum Systems © 2021 Tanknology Inc., Austin, TX. All rights reserved. tanknology.com Impact Valve Inspection Impact Valve Operational Inspection Work Order:3452695 Date:10/19/2021 Site Name/ID:SAM'S CLUB # 4819 Address:5625 GOSFORD ROAD City:BAKERSFIELD State:CA Zip:93313 How Inspected: Line Test NFPA 30A PEI RP1200 Other Dispenser Number Grade Secure Mount? Valve Lock?Pass/ Fail Comments 1/2 87 Pass Fail Not Tested 1/2 91 Pass Fail Not Tested 3/4 87 Pass Fail Not Tested 3/4 91 Pass Fail Not Tested 5/6 87 Pass Fail Not Tested 5/6 91 Pass Fail Not Tested 7/8 40 Pass Fail Not Tested 7/8 87 Pass Fail Not Tested 7/8 91 Pass Fail Not Tested 9/10 87 Pass Fail Not Tested 9/10 91 Pass Fail Not Tested 11/12 87 Pass Fail Not Tested 11/12 91 Pass Fail Not Tested 13/14 87 Pass Fail Not Tested 13/14 91 Pass Fail Not Tested 15/16 40 Pass Fail Not Tested 15/16 87 Pass Fail Not Tested 15/16 91 Pass Fail Not Tested Technician Comments: Technician Name:Patrick Pfrang Signature: Environmental Compliance for Petroleum Systems ©2021 Tanknology Inc., Austin, TX. All rights reserved. tanknology.com Tanknology, Inc.800-964-1250 11000 N Mopac Expy #500 Austin, Tx 78759 Patrick Pfrang 10027021 10/19/2021 SAM'S CLUB # 4819 5625 GOSFORD ROAD BAKERSFIELD 93313 Class A General Engineering 743160 8202676 02/03/2023 08/27/2023 11/02/2022 10/19/2021 6 Veeder Root:ATG Technician VMI:TLDT-5000 Tester Veeder Root TLS-350 336.00 L1 87 N ANNULAR L2 L3 87 N STP 794380-304 L4 L5 L6 L7 91 - DIESEL ANNULAR L8 L9 91 STP 794380-304 L10 L11 L12 DISP 3-4 794380-304 L13 DISP 5-6 794380-304 L14 DISP 7-8 794380-304 L15 DISP 11-12 794380-304 L16 DISP 13-14 794380-304 L17 DISP 15-16 794380-304 L18 VENT BOX 794380-304 L19 L20 DISP 9-10 794380-304 s1 87 N PRODUCT s2 87 N VENT-HIRT LINE s3 87 S PRODUCT 87 S VENTs4 794380-303 87 N FILL 794380-304 87 S ANNULAR 87 S FILL 794380-304 87 S STP 794380-304 91 FILL 794380-304 DIESEL FILL 794380-304 DIESEL STP 794380-304 DISP 1-2 794380-304 794380-208 794380-208 794380-303 794380-208 794380-208 794380-303 794380-208 794380-208 794380-208 794380-208 794380-208 794380-208 794380-208 794380-208 794380-208 794380-208 794380-208 794380-208 794380-208 330020-480 330020-480 330020-485 330020-485 s5 VAPOR RETURN s6 s7 91 PRODUCT NORTH s8 s9 s10 s11 DIESEL VENT 330020-485 91 PRODUCT SOUTH 91 VENT 91 LINE TO VENT BOX DIESEL PRODUCT 330020-486 330020-486 330020-486 330020-486 330020-480 330020-480 T1 T1 87 NORTH T2 T3 T3 91 T4 T4 DIESEL Red Jacket FX1V T2 87 SOUTHRed Jacket FX1V Red Jacket FX1V Red Jacket FX1DV T1 87 NORTH T2 87 SOUTH T3 91 T4 DIESEL All tank and dispenser sumps have VR 2 to 1 sensor input box for sensors. Each sump has a VR 208 and VR 304 sensor including the vent sump. 846390-111 846390-111 846390-111 846390-111 10/19/2021 10027021 10/19/2021 SAM'S CLUB # 4819 5625 GOSFORD ROAD BAKERSFIELD 93313 Tanknology, Inc.800-964-1250 11000 N Mopac Expy #500 Austin, TX 78759 Patrick Pfrang 743160 8202676 02/03/2023 04/02/2023 PEI RP1200 Fill Buckets 10/19/2021 2 OPW:EVR Phase 1 T1 87 NORTH FILL T2 87 SOUTH FILL T3 91 T4 DSL OPW OPW OPW OPW SWRCB, January 2006 Spill Bucket Testing Report Form This form is intended for use by contractors performing annual testing of UST spill containment structures. The completed form and printouts from tests (if applicable), should be provided to the facility owner/operator for submittal to the local regulatory agency. 1. FACILITY INFORMATION Facility Name: SAM'S CLUB # 4819 Date of Testing: 10/19/2021 Facility Address: 5625 GOSFORD ROAD , BAKERSFIELD, CA 93313 Facility Contact: Asset Protection Manager Phone: 661-654-8565 Date Local Agency Was Notified of Testing: 9/24/2021 Name of Local Agency Inspector (if present during testing): Peter Armagost/Marty 2. TESTING CONTRACTOR INFORMATION Company Name: TANKNOLOGY INC. Technician Conducting Test: Patrick Pfrang Credentials1: CSLB Contractor ICC Service Tech. SWRCB Tank Tester Other (Specify) License Number(s): 743160 3. SPILL BUCKET TESTING INFORMATION Test Method Used By: Hydrostatic Vacuum Other Test Equipment Used: LAKE TEST Equipment Resolution: 0.0625 in. Identify Spill Bucket (By Tank Number, Stored Product, etc.) Bucket Installation Type: Bucket Diameter: Bucket Depth: Wait time between applying vacuum/water and start of test Test Start Time (TI): Initial Reading (RI): Test End Time(TF): Final Reading (RF): Test Duration(TF–TI): Change in Reading (RF–RI) : Pass/Fail Threshold or Criteria: Test Result: Spill Box # Tank 1 UNLEADED - Fill 1 - Direct - Grade level in containment sump Direct Bury Contained in Sump 12.00 14.00 15 min 08:39:00 12.50 in. 09:39:00 12.50 in. 1 hr 0.00 in. +/- 0.00 Pass Spill Box # Tank 2 UNLEADED - Fill 1 - Direct - Grade level in containment sump Direct Bury Contained in Sump 12.00 14.00 15 min 08:39:00 12.50 in. 09:39:00 12.50 in. 1 hr 0.00 in. +/- 0.00 Pass Spill Box # Tank 3 PREMIUM - Fill 1 - Direct - Grade level in containment sump Direct Bury Contained in Sump 12.00 14.00 15 min 09:56:00 12.50 in. 10:56:00 12.50 in. 1 hr 0.00 in. +/- 0.00 Pass Spill Box # Tank 4 DIESEL2 - Fill 1 - Direct - Grade level in containment sump Direct Bury Contained in Sump 12.00 14.00 15 min 09:56:00 12.50 in. 10:56:00 12.50 in. 1 hr 0.00 in. +/- 0.00 Pass Comments - (include information on repairs made prior to testing, and recommended follow-up for failed tests) CERTIFICATION OF TECHNICIAN RESPONSIBLE FOR CONDUCTING THIS TESTING I hereby certify that all the information contained in this report is true, accurate, and in full compliance with legal requirements. Technician's Signature:Date:10/19/2021 1State laws and regulations do not currently require testing to be performed by a qualified contractor. However, local requirements may be more stringent. WO: 3452695 Site Diagram (This site diagram is for reference only and is not drawn to scale) Work Order:3452695 Site ID / Name:SC4819 / SAM'S CLUB # 4819 Address:5625 GOSFORD ROAD City:BAKERSFIELD State:CA Zip:93313 W.O.# SC1-3452695 +AAE- I50301 OCT 19, 2021 1:02 PM +ACM- 1:281428 +AAM- +AAE- I50302 OCT 19, 2021 1:02 PM +ACM- 2:SAMS CLUB 4819 +AAM- +AAE- I50303 OCT 19, 2021 1:02 PM +ACM- 3:5625 GOSFORD RD. +AAM- +AAE- I50304 OCT 19, 2021 1:02 PM +ACM- 4:BAKERSFIELD CA.93313 +AAM- +AAE- I51700 OCT 19, 2021 1:02 PM SYSTEM TYPE AND LANGUAGE FLAG SYSTEM UNITS U.S. SYSTEM LANGUAGE ENGLISH SYSTEM DATE/TIME FORMAT MON DD YYYY HH:MM:SS xM +AAM- +AAE- I50F00 OCT 19, 2021 1:02 PM MON DD YYYY HH:MM:SS xM +AAM- +AAE- I10200 OCT 19, 2021 1:02 PM 281428 SAMS CLUB 4819 5625 GOSFORD RD. BAKERSFIELD CA.93313 SYSTEM CONFIGURATION SLOT BOARD TYPE POWER ON RESET CURRENT 1 4 PROBE / G.T. 162479 162527 2 INTERSTITIAL BD 201477 201549 3 INTERSTITIAL BD 201958 201802 4 INTERSTITIAL BD 201431 201503 5 8SMARTSENSOR BD 39356 39359 6 8SMARTSENSOR BD 39356 39381 7 7SMARTSENSOR BD 507644 508031 8 UNUSED 4794385 4825486 9 RELAY BOARD 14971 14992 10 RELAY BOARD 14929 14929 11 STP SENSE BOARD 32912 32953 12 COMBO I/O BOARD 9930 9912 13 UNUSED 4791762 4830547 14 UNUSED 4786873 4827629 15 UNUSED 4786726 4825154 16 UNUSED 4786557 4824605 COMM 1 RS232 SERIAL BD 14950 14865 COMM 2 ELEC DISP INT. 101043 101031 COMM 3 RS232 SERIAL BD 482338 14503 COMM 4 UNUSED 4785778 4830314 COMM 5 UNUSED 4786262 4825662 COMM 6 UNUSED 4785841 4828073 +AAM- +AAE- I60100 OCT 19, 2021 1:02 PM TANK CONFIGURATION DEVICE LABEL CONFIGURED 1 87 NORTH ON 2 87 SOUTH ON 3 91 ON 4 DIESEL ON +AAM- +AAE- I60200 OCT 19, 2021 1:02 PM TANK PRODUCT LABEL TANK PRODUCT LABEL 1 87 NORTH 2 87 SOUTH 3 91 4 DIESEL +AAM- +AAE- I60300 OCT 19, 2021 1:02 PM TANK PRODUCT CODE TANK PRODUCT LABEL 1 87 NORTH 1 2 87 SOUTH 1 3 91 3 4 DIESEL 4 +AAM- +AAE- I60400 OCT 19, 2021 1:02 PM TANK FULL VOLUME TANK PRODUCT LABEL GALLONS 1 87 NORTH 19782 2 87 SOUTH 19782 3 91 11904 4 DIESEL 7901 +AAM- +AAE- I60700 OCT 19, 2021 1:02 PM TANK DIAMETER TANK PRODUCT LABEL INCHES 1 87 NORTH 118.38 2 87 SOUTH 118.38 3 91 118.38 4 DIESEL 118.38 +AAM- +AAE- I60900 OCT 19, 2021 1:02 PM TANK THERMAL COEFFICIENT TANK PRODUCT LABEL 1 87 NORTH 0.000700 2 87 SOUTH 0.000700 3 91 0.000700 4 DIESEL 0.000450 +AAM- +AAE- I61200 OCT 19, 2021 1:02 PM TANK MANIFOLDED PARTNERS TANK PRODUCT LABEL SIPHON MANIFOLDED TANKS LINE MANIFOLDED TANKS 1 87 NORTH 2 NONE 2 87 SOUTH 1 NONE 3 91 NONE NONE 4 DIESEL NONE NONE +AAM- +AAE- I62100 OCT 19, 2021 1:02 PM TANK LOW PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 87 NORTH 950 2 87 SOUTH 950 3 91 500 4 DIESEL 400 +AAM- +AAE- I62200 OCT 19, 2021 1:02 PM TANK HIGH PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 87 NORTH 18793 2 87 SOUTH 18793 3 91 11309 4 DIESEL 7506 +AAM- +AAE- I62300 OCT 19, 2021 1:02 PM TANK OVERFILL LEVEL LIMIT TANK PRODUCT LABEL GALLONS 1 87 NORTH 17804 2 87 SOUTH 17804 3 91 10714 4 DIESEL 7111 +AAM- +AAE- I62400 OCT 19, 2021 1:02 PM TANK HIGH WATER LEVEL LIMIT TANK PRODUCT LABEL INCHES 1 87 NORTH 3.0 2 87 SOUTH 3.0 3 91 3.0 4 DIESEL 3.0 +AAM- +AAE- I62800 OCT 19, 2021 1:02 PM TANK MAXIMUM VOLUME LIMIT TANK PRODUCT LABEL GALLONS 1 87 NORTH 19782 2 87 SOUTH 19782 3 91 11904 4 DIESEL 7901 +AAM- +AAE- I62900 OCT 19, 2021 1:02 PM TANK DELIVERY REQUIRED LIMIT TANK PRODUCT LABEL GALLONS 1 87 NORTH 2955 2 87 SOUTH 2955 3 91 1800 4 DIESEL 1200 +AAM- +AAE- I70300 OCT 19, 2021 1:02 PM LIQUID TYPE SENSOR LOCATION TYPE 1 87 N ANNULAR DUAL POINT HYDROSTATIC 2 87 87 N FILL DW SUMP 2-1 3 87 N STP DW SUMP 2-1 4 87 S ANNULAR DUAL POINT HYDROSTATIC 5 87 S FILL DW SUMP 2-1 6 87 S STP DW SUMP 2-1 7 91-DIESEL ANNULAR DUAL POINT HYDROSTATIC 8 91 FILL DW SUMP 2-1 9 91 STP DW SUMP 2-1 10 DIESEL FILL DW SUMP 2-1 11 DIESEL STP DW SUMP 2-1 12 DISP. 3-4 DW SUMP 2-1 13 DISP. 5-6 DW SUMP 2-1 14 DISP. 7-8 DW SUMP 2-1 15 DISP.11-12 DW SUMP 2-1 16 DISP.13-14 DW SUMP 2-1 17 DISP.15-16 DW SUMP 2-1 18 VENT BOX DW SUMP 2-1 19 DISP 1-2 DW SUMP 2-1 20 DISP 9-10 DW SUMP 2-1 21 TRI-STATE (SINGLE FLOAT) 22 TRI-STATE (SINGLE FLOAT) 23 TRI-STATE (SINGLE FLOAT) 24 TRI-STATE (SINGLE FLOAT) +AAM- +AAE- I72100 OCT 19, 2021 1:02 PM SMART SENSOR CONFIGURATION DEVICE LABEL CONFIGURED 1 87 N PRODUCT ON 2 87 N VENT-HIRT LINE ON 3 87 S PRODUCT ON 4 87 S VENT ON 5 VAPOR RETURN ON 6 91 PRODUCT SOUTH ON 7 91 PRODUCT NORTH ON 8 91 VENT ON 9 91 LINE TO VENT BOX ON 10 DIESEL PRODUCT ON 11 DIESEL VENT ON 12 AFM DISP 1-2 ON 13 AFM DISP 3-4 ON 14 AFM DISP 5-6 ON 15 AFM DISP 7-8 ON 16 AFM DISP 9-10 ON 17 AFM DISP 11-12 ON 18 VPS DISP 7-8 ON 19 AFM DISP 13-14 ON 20 AFM DISP 15-16 ON 21 OFF 22 OFF 23 OFF 24 ATM PRESSURE SENSOR ON +AAM- +AAE- I72200 OCT 19, 2021 1:02 PM SMART SENSOR LABEL DEVICE LABEL 1 87 N PRODUCT 2 87 N VENT-HIRT LINE 3 87 S PRODUCT 4 87 S VENT 5 VAPOR RETURN 6 91 PRODUCT SOUTH 7 91 PRODUCT NORTH 8 91 VENT 9 91 LINE TO VENT BOX 10 DIESEL PRODUCT 11 DIESEL VENT 12 AFM DISP 1-2 13 AFM DISP 3-4 14 AFM DISP 5-6 15 AFM DISP 7-8 16 AFM DISP 9-10 17 AFM DISP 11-12 18 VPS DISP 7-8 19 AFM DISP 13-14 20 AFM DISP 15-16 21 22 23 24 ATM PRESSURE SENSOR +AAM- +AAE- I72900 OCT 19, 2021 1:02 PM VACUUM SENSOR PUMP NUMBER DEVICE LABEL PUMP NUMBER 1 87 N PRODUCT R 5:87 NORTH 2 87 N VENT-HIRT LINE R 5:87 NORTH 3 87 S PRODUCT R 6:87 SOUTH 4 87 S VENT R 6:87 SOUTH 5 VAPOR RETURN R 6:87 SOUTH 6 91 PRODUCT SOUTH R 7:91 7 91 PRODUCT NORTH R 7:91 8 91 VENT R 7:91 9 91 LINE TO VENT BOX R 7:91 10 DIESEL PRODUCT R 8:DIESEL 11 DIESEL VENT R 8:DIESEL +AAM- +AAE- I72A00 OCT 19, 2021 1:02 PM VACUUM SENSOR VOLUME DEVICE LABEL VOLUME 1 87 N PRODUCT 43.0 GALLONS 2 87 N VENT-HIRT LINE 20.6 GALLONS 3 87 S PRODUCT 43.4 GALLONS 4 87 S VENT 20.8 GALLONS 5 VAPOR RETURN 94.9 GALLONS 6 91 PRODUCT SOUTH 48.3 GALLONS 7 91 PRODUCT NORTH 48.3 GALLONS 8 91 VENT 25.5 GALLONS 9 91 LINE TO VENT BOX 0.4 GALLONS 10 DIESEL PRODUCT 17.3 GALLONS 11 DIESEL VENT 29.9 GALLONS +AAM- +AAE- I72B00 OCT 19, 2021 1:02 PM VACUUM SENSOR RELIEF VALVE PRESENT DEVICE LABEL RELIEF VALVE 1 87 N PRODUCT NO 2 87 N VENT-HIRT LINE NO 3 87 S PRODUCT NO 4 87 S VENT NO 5 VAPOR RETURN NO 6 91 PRODUCT SOUTH NO 7 91 PRODUCT NORTH NO 8 91 VENT NO 9 91 LINE TO VENT BOX NO 10 DIESEL PRODUCT NO 11 DIESEL VENT NO +AAM- +AAE- I72C00 OCT 19, 2021 1:02 PM VACUUM SENSOR RELIEF VALVE PRESSURE DEVICE LABEL RELIEF VALVE PRESSURE 1 87 N PRODUCT -9.0 PSI 2 87 N VENT-HIRT LINE -9.0 PSI 3 87 S PRODUCT -9.0 PSI 4 87 S VENT -9.0 PSI 5 VAPOR RETURN -9.0 PSI 6 91 PRODUCT SOUTH -9.0 PSI 7 91 PRODUCT NORTH -9.0 PSI 8 91 VENT -9.0 PSI 9 91 LINE TO VENT BOX -9.0 PSI 10 DIESEL PRODUCT -9.0 PSI 11 DIESEL VENT -9.0 PSI +AAM- +AAE- I61500 OCT 19, 2021 1:02 PM TANK PRODUCT LABEL METER DATA 1 87 NORTH YES 2 87 SOUTH YES 3 91 YES 4 DIESEL YES +AAM- +AAE- I90200 OCT 19, 2021 1:03 PM SOFTWARE REVISION LEVEL VERSION 336.00 SOFTWARE+ACM- 346336-100-A CREATED - 19.12.13.15.19 S-MODULE+ACM- 330160-106-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS CSLD BIR ISD/APM +AAM- +AAE- I20600 OCT 19, 2021 1:03 PM 281428 SAMS CLUB 4819 5625 GOSFORD RD. BAKERSFIELD CA.93313 TANK ALARM HISTORY TANK 1 87 NORTH HIGH WATER ALARM OCT 19, 2021 8:46 AM SEP 28, 2021 9:19 AM AUG 24, 2020 10:53 AM OVERFILL ALARM OCT 19, 2021 9:00 AM SEP 28, 2021 9:27 AM SEP 28, 2021 9:09 AM LOW PRODUCT ALARM OCT 19, 2021 8:42 AM AUG 28, 2021 12:28 PM JAN 26, 2021 6:07 PM SUDDEN LOSS ALARM NOV 30, 2020 6:58 AM NOV 30, 2020 6:43 AM NOV 23, 2020 7:10 AM HIGH PRODUCT ALARM OCT 19, 2021 9:00 AM AUG 24, 2020 11:21 AM INVALID FUEL LEVEL OCT 30, 2020 9:33 AM PROBE OUT OCT 19, 2021 9:01 AM OCT 19, 2021 8:42 AM SEP 28, 2021 9:27 AM HIGH WATER WARNING OCT 19, 2021 8:46 AM SEP 28, 2021 9:08 AM AUG 24, 2020 10:53 AM DELIVERY NEEDED OCT 19, 2021 8:42 AM OCT 18, 2021 11:03 AM OCT 17, 2021 6:17 PM MAX PRODUCT ALARM OCT 19, 2021 9:00 AM AUG 24, 2020 11:22 AM LOW TEMP WARNING OCT 19, 2021 9:01 AM SEP 28, 2021 9:28 AM AUG 24, 2020 11:25 AM TANK 2 87 SOUTH HIGH WATER ALARM AUG 24, 2020 10:53 AM OVERFILL ALARM SEP 28, 2021 9:09 AM JUL 29, 2021 4:36 AM JUN 30, 2021 6:12 AM LOW PRODUCT ALARM OCT 19, 2021 8:41 AM OCT 18, 2021 12:07 PM JAN 26, 2021 6:16 PM SUDDEN LOSS ALARM OCT 30, 2020 10:41 AM SEP 17, 2020 8:13 AM SEP 4, 2020 7:37 AM HIGH PRODUCT ALARM OCT 19, 2021 9:07 AM AUG 24, 2020 11:44 AM INVALID FUEL LEVEL OCT 19, 2021 8:41 AM OCT 30, 2020 9:35 AM AUG 24, 2020 10:48 AM PROBE OUT OCT 19, 2021 9:07 AM OCT 19, 2021 8:41 AM SEP 28, 2021 9:14 AM HIGH WATER WARNING OCT 19, 2021 8:46 AM AUG 24, 2020 10:53 AM DELIVERY NEEDED OCT 19, 2021 8:40 AM OCT 18, 2021 8:20 AM OCT 17, 2021 6:32 PM MAX PRODUCT ALARM OCT 19, 2021 9:07 AM AUG 24, 2020 11:47 AM LOW TEMP WARNING SEP 28, 2021 9:15 AM SEP 28, 2021 9:09 AM AUG 24, 2020 11:49 AM TANK 3 91 HIGH WATER ALARM OCT 19, 2021 8:47 AM AUG 24, 2020 10:54 AM OVERFILL ALARM OCT 19, 2021 9:02 AM SEP 28, 2021 9:20 AM SEP 15, 2021 3:25 AM LOW PRODUCT ALARM OCT 19, 2021 8:44 AM OCT 17, 2021 1:52 PM AUG 28, 2021 12:38 PM HIGH PRODUCT ALARM OCT 19, 2021 9:03 AM AUG 24, 2020 11:54 AM PROBE OUT OCT 19, 2021 9:03 AM OCT 19, 2021 8:43 AM SEP 28, 2021 9:23 AM HIGH WATER WARNING OCT 19, 2021 8:47 AM AUG 24, 2020 10:54 AM DELIVERY NEEDED OCT 19, 2021 8:44 AM OCT 17, 2021 4:49 PM OCT 17, 2021 10:43 AM MAX PRODUCT ALARM OCT 19, 2021 9:03 AM AUG 24, 2020 11:56 AM LOW TEMP WARNING OCT 19, 2021 9:04 AM SEP 28, 2021 9:25 AM SEP 28, 2021 9:22 AM TANK 4 DIESEL HIGH WATER ALARM OCT 19, 2021 8:45 AM AUG 24, 2020 10:53 AM OVERFILL ALARM OCT 19, 2021 9:04 AM SEP 28, 2021 9:16 AM SEP 8, 2021 1:48 AM LOW PRODUCT ALARM OCT 19, 2021 8:42 AM AUG 24, 2020 10:47 AM SUDDEN LOSS ALARM AUG 24, 2020 11:01 AM HIGH PRODUCT ALARM OCT 19, 2021 9:04 AM AUG 24, 2020 11:34 AM INVALID FUEL LEVEL OCT 19, 2021 8:42 AM AUG 24, 2020 10:50 AM PROBE OUT OCT 19, 2021 9:05 AM OCT 19, 2021 8:41 AM SEP 28, 2021 9:17 AM HIGH WATER WARNING OCT 19, 2021 8:45 AM AUG 24, 2020 11:37 AM AUG 24, 2020 10:53 AM DELIVERY NEEDED OCT 19, 2021 8:42 AM AUG 3, 2021 8:36 AM JUL 27, 2021 4:46 PM MAX PRODUCT ALARM OCT 19, 2021 9:05 AM AUG 24, 2020 11:34 AM LOW TEMP WARNING SEP 28, 2021 9:18 AM JUL 23, 2021 2:01 PM TANK 5 TANK 6 TANK 7 TANK 8 TANK 9 TANK 10 TANK 11 TANK 12 TANK 13 TANK 14 TANK 15 TANK 16 +AAM- +AAE- I30200 OCT 19, 2021 1:03 PM 281428 SAMS CLUB 4819 5625 GOSFORD RD. BAKERSFIELD CA.93313 LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 87 N ANNULAR OCT 19, 2021 9:52 AM HIGH LIQUID ALARM OCT 19, 2021 9:52 AM LOW LIQUID ALARM OCT 19, 2021 9:20 AM SENSOR OUT ALARM 2 87 87 N FILL OCT 19, 2021 9:51 AM LOW LIQUID ALARM OCT 19, 2021 9:51 AM FUEL ALARM OCT 19, 2021 9:20 AM SENSOR OUT ALARM 3 87 N STP OCT 19, 2021 9:51 AM LOW LIQUID ALARM OCT 19, 2021 9:50 AM FUEL ALARM OCT 19, 2021 9:20 AM SENSOR OUT ALARM 4 87 S ANNULAR OCT 19, 2021 9:55 AM HIGH LIQUID ALARM OCT 19, 2021 9:55 AM LOW LIQUID ALARM OCT 19, 2021 9:20 AM SENSOR OUT ALARM 5 87 S FILL OCT 19, 2021 9:55 AM LOW LIQUID ALARM OCT 19, 2021 9:54 AM FUEL ALARM OCT 19, 2021 9:20 AM SENSOR OUT ALARM 6 87 S STP OCT 19, 2021 9:54 AM LOW LIQUID ALARM OCT 19, 2021 9:54 AM FUEL ALARM OCT 19, 2021 9:20 AM SENSOR OUT ALARM 7 91-DIESEL ANNULAR OCT 19, 2021 9:58 AM HIGH LIQUID ALARM OCT 19, 2021 9:57 AM LOW LIQUID ALARM OCT 19, 2021 9:20 AM SENSOR OUT ALARM 8 91 FILL OCT 19, 2021 9:57 AM LOW LIQUID ALARM OCT 19, 2021 9:56 AM FUEL ALARM OCT 19, 2021 9:24 AM LOW LIQUID ALARM 9 91 STP OCT 19, 2021 9:57 AM LOW LIQUID ALARM OCT 19, 2021 9:57 AM FUEL ALARM OCT 19, 2021 9:20 AM SENSOR OUT ALARM 10 DIESEL FILL OCT 19, 2021 10:01 AM LOW LIQUID ALARM OCT 19, 2021 9:59 AM FUEL ALARM OCT 19, 2021 9:20 AM SENSOR OUT ALARM 11 DIESEL STP OCT 19, 2021 10:00 AM LOW LIQUID ALARM OCT 19, 2021 10:00 AM FUEL ALARM OCT 19, 2021 9:20 AM SENSOR OUT ALARM 12 DISP. 3-4 OCT 19, 2021 10:10 AM LOW LIQUID ALARM OCT 19, 2021 10:10 AM FUEL ALARM OCT 19, 2021 9:20 AM SENSOR OUT ALARM 13 DISP. 5-6 OCT 19, 2021 10:09 AM LOW LIQUID ALARM OCT 19, 2021 10:07 AM FUEL ALARM OCT 19, 2021 9:20 AM SENSOR OUT ALARM 14 DISP. 7-8 OCT 19, 2021 10:05 AM LOW LIQUID ALARM OCT 19, 2021 10:05 AM FUEL ALARM OCT 19, 2021 9:20 AM SENSOR OUT ALARM 15 DISP.11-12 OCT 19, 2021 10:20 AM LOW LIQUID ALARM OCT 19, 2021 10:19 AM FUEL ALARM OCT 19, 2021 9:20 AM SENSOR OUT ALARM 16 DISP.13-14 OCT 19, 2021 10:22 AM LOW LIQUID ALARM OCT 19, 2021 10:22 AM FUEL ALARM OCT 19, 2021 9:20 AM SENSOR OUT ALARM 17 DISP.15-16 OCT 19, 2021 10:24 AM LOW LIQUID ALARM OCT 19, 2021 10:24 AM FUEL ALARM OCT 19, 2021 9:20 AM SENSOR OUT ALARM 18 VENT BOX OCT 19, 2021 10:40 AM LOW LIQUID ALARM OCT 19, 2021 10:39 AM FUEL ALARM OCT 19, 2021 9:20 AM SENSOR OUT ALARM 19 DISP 1-2 OCT 19, 2021 10:13 AM LOW LIQUID ALARM OCT 19, 2021 10:13 AM FUEL ALARM OCT 19, 2021 9:20 AM SENSOR OUT ALARM 20 DISP 9-10 OCT 19, 2021 10:17 AM LOW LIQUID ALARM OCT 19, 2021 10:17 AM FUEL ALARM OCT 19, 2021 9:20 AM SENSOR OUT ALARM +AAM- +AAE- I31600 OCT 19, 2021 1:03 PM 281428 SAMS CLUB 4819 5625 GOSFORD RD. BAKERSFIELD CA.93313 +AAE- I31600 OCT 19, 2021 1:05 PM 281428 SAMS CLUB 4819 5625 GOSFORD RD. BAKERSFIELD CA.93313 SMART SENSOR ALARM HISTORY REPORT SENSOR LOCATION 1 87 N PRODUCT OCT 19, 2021 9:28 AM NO VACUUM ALARM OCT 19, 2021 9:28 AM HIGH LIQUID ALARM OCT 12, 2021 10:31 AM HIGH LIQUID ALARM 2 87 N VENT-HIRT LINE OCT 19, 2021 9:28 AM HIGH LIQUID ALARM OCT 19, 2021 9:28 AM NO VACUUM ALARM OCT 12, 2021 10:31 AM HIGH LIQUID ALARM 3 87 S PRODUCT OCT 19, 2021 9:31 AM NO VACUUM ALARM OCT 19, 2021 9:31 AM HIGH LIQUID ALARM OCT 12, 2021 10:35 AM HIGH LIQUID ALARM 4 87 S VENT OCT 19, 2021 9:31 AM HIGH LIQUID ALARM OCT 19, 2021 9:31 AM NO VACUUM ALARM OCT 12, 2021 10:35 AM HIGH LIQUID ALARM 5 VAPOR RETURN OCT 19, 2021 9:31 AM HIGH LIQUID ALARM OCT 19, 2021 9:31 AM NO VACUUM ALARM OCT 12, 2021 10:35 AM HIGH LIQUID ALARM 6 91 PRODUCT SOUTH OCT 19, 2021 9:39 AM NO VACUUM ALARM OCT 19, 2021 9:38 AM HIGH LIQUID ALARM OCT 12, 2021 10:44 AM HIGH LIQUID ALARM 7 91 PRODUCT NORTH OCT 19, 2021 9:39 AM NO VACUUM ALARM OCT 19, 2021 9:38 AM HIGH LIQUID ALARM OCT 12, 2021 10:44 AM HIGH LIQUID ALARM 8 91 VENT OCT 19, 2021 9:39 AM NO VACUUM ALARM OCT 19, 2021 9:38 AM HIGH LIQUID ALARM OCT 12, 2021 10:44 AM HIGH LIQUID ALARM 9 91 LINE TO VENT BOX OCT 19, 2021 9:39 AM NO VACUUM ALARM OCT 19, 2021 9:38 AM HIGH LIQUID ALARM OCT 12, 2021 10:44 AM HIGH LIQUID ALARM 10 DIESEL PRODUCT OCT 19, 2021 9:35 AM NO VACUUM ALARM OCT 19, 2021 9:35 AM HIGH LIQUID ALARM OCT 12, 2021 10:39 AM HIGH LIQUID ALARM 11 DIESEL VENT OCT 19, 2021 9:35 AM NO VACUUM ALARM OCT 19, 2021 9:35 AM HIGH LIQUID ALARM OCT 12, 2021 10:39 AM HIGH LIQUID ALARM 12 AFM DISP 1-2 NOV 4, 2020 9:54 AM COMMUNICATION ALARM 13 AFM DISP 3-4 NOV 4, 2020 9:55 AM COMMUNICATION ALARM 14 AFM DISP 5-6 NOV 4, 2020 9:56 AM COMMUNICATION ALARM 15 AFM DISP 7-8 NOV 4, 2020 10:40 AM COMMUNICATION ALARM NOV 4, 2020 10:38 AM COMMUNICATION ALARM NOV 4, 2020 9:57 AM COMMUNICATION ALARM 16 AFM DISP 9-10 NOV 4, 2020 9:58 AM COMMUNICATION ALARM MAR 21, 2020 2:28 PM COMMUNICATION ALARM MAR 21, 2020 12:49 PM COMMUNICATION ALARM 17 AFM DISP 11-12 NOV 4, 2020 9:58 AM COMMUNICATION ALARM SEP 15, 2020 10:06 AM COMMUNICATION ALARM 18 VPS DISP 7-8 NOV 4, 2020 11:11 AM COMMUNICATION ALARM NOV 4, 2020 9:58 AM COMMUNICATION ALARM MAR 18, 2020 10:50 AM COMMUNICATION ALARM 19 AFM DISP 13-14 NOV 4, 2020 10:00 AM COMMUNICATION ALARM OCT 28, 2020 9:10 AM COMMUNICATION ALARM OCT 27, 2020 3:12 PM COMMUNICATION ALARM 20 AFM DISP 15-16 NOV 4, 2020 11:09 AM COMMUNICATION ALARM NOV 4, 2020 10:42 AM COMMUNICATION ALARM NOV 4, 2020 10:36 AM COMMUNICATION ALARM 24 ATM PRESSURE SENSOR +AAM- Test Duration Test Pressure P/F Threshold Tank Annular - Vacuum 1 hr, 20k or less tank 10" hg 0 loss, int dry before and after test Tank Annular - Vacuum 2 hr, >20k tank 10" hg 0 loss, int dry before and after test Line Annular - Pressure 1 hr 5 psi 0 loss STP Sump - Hydro 1 hr 4" above highest penetration or sidewall seam less than 1/8" over hour, settle time of 15 minutes minimum prior to starting the test UDC Sump - Hydro 1 hr 4" above highest penetration or sidewall seam less than 1/8" over hour, settle time of 15 minutes minimum prior to starting the test Spill Bucket - SW Vac 1 min 30" wc no greater than 4" wc vaccum decay - bucket must be dry Spill Bucket - SW Hydro 1 hr within 1.5" of top of the bucket less than 1/8" over hour, settle time of 5 minutest minimum prior to starting the test Spill Bucket - DW Vac 1 min 15" wc no greater than 3" wc vaccum decay - int must be dry