Loading...
HomeMy WebLinkAboutFMC (SOUTH) 2021Appendix VI Underground Storage Tank Monitoring System Certification Form CERS = California Environmental Reporting System, GPH = Gallons Per Hour, ID = Identification, ICC = International Code Council, LLD = Line Leak Detector, NA = Not Applicable, SW = Single- Walled, UDC = Under-Dispenser Containment, UST = Underground Storage Tank, VPH = Vacuum/Pressure/Hydrostatic Page 1 of 6 TYPE OF ACTION ܆܆ Installation ܆ Repair ܆ 12 Month 1. FACILITY INFORMATION CERS ID Certification Date Facility Name Facility Address City ZIP Code 2. SERVICE TECHNICIAN INFORMATION Company Performing the Certification Phone Mailing Address Service Technician Performing Test Contractor/Tank Tester License Number ICC Number ICC Expiration Date 3. TRAINING AND CERTIFICATIONS Manufacturer and Test Equipment Training Certifications Expiration Date 4. CERTIFICATION BY SERVICE TECHNICIAN CONDUCTING TEST I hereby certify that the monitoring system is operational in accordance with California Code of Regulations, title 23, division 3, chapter 16, section 2638; that required supporting documentation is attached; and all information contained herein is accurate. Service Technician Signature Date Total # of Pages 10155965 9-28-21 Jaco #5562 Fastrip #6 1640 South Chester Avenue Bakersfield 93304 Confidence UST Services, Inc.(800) 339-9930 2209 Zeus Court, Bakersfield, CA 93308 Payton Phillips 804904 9482312 1-30-22 Veedor Root C27796 7-29-22 9-28-21 6 Underground Storage Tank Monitoring System Certification Form Page 2 of 6 5. MONITORING SYSTEM AND PROGRAMMING A separate Monitoring System Certification Form must be prepared for each control panel. Make of Monitoring System Control Panel Model of Monitoring System Control Panel Software Version Installed Attach the post-certification reports if the monitoring system is capable of generating either; ܆܆Monitoring System Set-up ܆܆ Alarm History Report Yes No NA All monitoring equipment is operational per manufacturer’s specifications? ܆܆܆܆ Secondary containment systems are free of damage, debris, or liquid? ܆܆܆܆ Are the audible and visual alarms operational? ܆܆܆܆ All sensors have been: 1) visually inspected for wiring kinks, breaks and residual buildup on floats; and 2) tested for functionality and confirmed operational? ܆܆܆܆܆܆ Are all sensors installed to detect a release at the earliest opportunity in the secondary containment? ܆܆܆܆܆܆ The monitoring system set-up was reviewed, and proper settings confirmed? ܆܆܆܆܆܆ Was the monitoring control panel’s backup battery visually inspected, functionally tested, and confirmed operational? ܆܆܆܆܆܆ Does the flow of fuel stop at the dispenser if a release is detected in the under- dispenser containment? ܆܆܆܆܆܆ Does the turbine automatically shut down if the piping secondary containment monitoring system fails to operate or is electrically disconnected? ܆܆܆܆܆܆ Does the turbine automatically shut down if the piping secondary containment monitoring system detects a release? Which sensors initiate positive shut down? (Check all that apply) ܆ Sump ܆ UDC ܆܆܆܆܆܆ If monitoring system alarms are relayed to a remote monitoring center, is all communication equipment operational? ܆܆܆܆܆܆ Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 Veedor Root TLS-350 329.01 Underground Storage Tank Monitoring System Certification Form Page 3 of 6 6. SENSOR TESTING RESULTS List only sensors tested on date of this certification. List “Sensor ID” as labeled in system programming. Additional copies of this page may be attached to accommodate all sensors tested. Sensor ID Sensor Model Component(s) Monitored Pass Fail ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 L1 794380-208 UNL 1 STP L2 794380-420 UNL 1 Ann L3 794380-208 Diesel STP L4 794380-420 Diesel Ann L5 794380-208 PNL STP L6 794380-420 PNL Ann L7 794380-208 UNL2 Siphon STP L8 794380-420 UNL2 Ann L9 794380-208 Disp 1-2 L10 794380-208 Disp 3-4 L11 794380-208 Disp 5-6 L12 794380-208 Disp 7-8 L13 794380-208 Tran No. L14 794380-208 Tran So. Underground Storage Tank Monitoring System Certification Form Page 4 of 6 7. LINE LEAK DETECTOR TESTING ܆܆ Check this box if line leak detectors ARE NOT installed. (Do not complete this section.) Simulated release rate verified: (Check all that apply.) ܆܆ 3 GPH ܆܆ 0.1 GPH ܆܆ 0.2 GPH Yes No NA Has the testing apparatus been properly calibrated? ܆܆ ܆܆ ܆܆ For emergency generator tank systems, does the LLD create an audible and visual alarm when a leak is detected? ܆܆ ܆܆ ܆܆ For mechanical LLDs, does the LLD restrict the flow through the pipe when a release is detected? ܆܆ ܆܆ ܆܆ For electronic LLDs, does the turbine automatically shut off when a release is detected? ܆܆ ܆܆ ܆܆ For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system is disabled or disconnected? ܆܆ ܆܆ ܆܆ For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system malfunctions or fails a tightness test? ܆܆ ܆܆ ܆܆ For electronic LLDs, have all accessible wiring connections been visually inspected for kinks and breaks? ܆܆ ܆܆ ܆܆ Were all items on the equipment manufacturer’s maintenance checklist completed? ܆܆ ܆܆ ܆܆ Were all LLDs confirmed operational within regulatory requirements? ܆܆ ܆܆ ܆܆ LLD ID LLD Model Lines Monitored Pass Fail ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 T1 FX1V Unleaded T2 FX1DV Diesel T3 FX1V PNL Underground Storage Tank Monitoring System Certification Form Page 5 of 6 8. IN-TANK GAUGING TESTING ܆܆ Check this box if tank gauging is used only for inventory control. ܆܆ Check this box if NO tank gauging equipment is installed. (Do not complete this section if either box is checked.) Yes No NA All wiring has been: 1) visually inspected for kinks, breaks and proper entry and termination; and 2) tested for ground faults? ܆܆ ܆܆ ܆܆ Were all in-tank gauging probes visually inspected for damage and residue buildup to ensure that floats move freely, functionally tested, and confirmed operational? ܆܆ ܆܆ Was accuracy of system’s product level readings tested? ܆܆ ܆܆ ܆܆ Was accuracy of system’s water level readings tested? ܆܆ ܆܆ ܆܆ Were all probes reinstalled properly? ܆܆ ܆܆ ܆܆ Were all items on the equipment manufacturer’s maintenance checklist completed? ܆܆ ܆܆ ܆܆ Probe ID Probe Model Tanks Monitored Pass Fail ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ 9. COMMENTS Describe all answers marked “No” or “Fail” and proposed remedy. List all monitoring equipment either replaced or repaired. ܆܆ Underground Storage Tank Monitoring System Certification Form Page 6 of 6 10. MONITORING SITE PLAN Date site plan was prepared: If a site plan has been prepared that shows all required information, you may include it, rather than this page, with your Monitoring System Certification Form. The site plan must show the general layout of tanks and identify locations of the monitoring panel, and all leak detection equipment and monitoring locations. Include a legend for all symbols depicted. 9-22-14 Appendix VIII Underground Storage Tank Spill Container Testing Report Form CERS = California Environmental Reporting System, ID = Identification, ICC = International Code Council Page 1 of 2 TYPE OF ACTION ܆܆ Installation ܆ Repair ܆ 12 Month 1. FACILITY INFORMATION CERS ID Test Date Facility Name Facility Address City ZIP Code 2. SERVICE TECHNICIAN INFORMATION Company Performing the Test Phone Mailing Address Service Technician Performing Test Contractor/Tank Tester License Number ICC Number ICC Expiration Date 3. TRAINING AND CERTIFICATIONS Manufacturer and Test Equipment Training Certifications Expiration Date 4. TEST PROCEDURE INFORMATION Test Procedures Used Components Tested 5. CERTIFICATION BY SERVICE TECHNICIAN CONDUCTING TEST I hereby certify that each spill container was tested in accordance with California Code of Regulations, title 23, division 3, chapter 16, section 2637.1; that required supporting documentation is attached; and all information contained herein is accurate. I understand that test procedures shall be made available upon request by the governing authority. Service Technician Signature Date Total # of Pages 10155965 9-28-21 Jaco #5562 Fastrip #6 1640 South Chester Avenue Bakersfield 93304 Confidence UST Services, Inc.(800) 339-9930 2209 Zeus Court, Bakersfield, CA 93308 Payton Phillips 804904 9482312 1-30-22 OPW 0187328 10/1/22 PEI 1200 OPW Spill buckets 9-28-21 2 Underground Storage Tank Spill Container Testing Report Form Additional copies of this page may be attached. Page 2 of 2 6. SPILL CONTAINER DETAILS Test Method Developed by ܆܆ Manufacturer ܆܆ Industry Standard ܆܆ Professional Engineer Test Type ܆܆ Pressure ܆܆ Vacuum ܆܆ Hydrostatic Tank ID Spill Container Manufacturer: Method of Cathodic Protection ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other Is the spill container minimum capacity five gallons excluding riser volume? ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* Method to keep spill container empty ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other Spill Container Test Results ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail Tank ID Spill Container Manufacturer: Method of Cathodic Protection ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other ܆܆ Nonmetallic ܆܆ Other Is the spill container minimum capacity five gallons excluding riser volume? ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* ܆܆ Yes ܆܆ No* Method to keep spill container empty ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other ܆܆ Drain ܆܆ Pump ܆܆ Other Spill Container Test Results ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail 1 8. COMMENTS Describe all answers marked “Other,” “No,” or “Fail” and each proposed remedy. * Mark here if: Spill containers do not have a minimum capacity of five gallons and require replacement. T1 UNL OPW T2 Diesel OPW T3 PNL OPW T4 UNL 2 Siphon OPW 9-28-21 FAST TRIP JACO 5562 MONITOR CERT SYSTEM SETUP Responses Received: 200 FASTRIP 562 MING-CHESTER BAKERSFIELD CA 661-397-8606 SEP 28, 2021 9:11 AM TANK PRODUCT GALLONS INCHES WATER DEG F ULLAGE 1 UNL 5666 45.72 0.0 82.9 6396 2 DIESEL 2613 25.82 0.0 87.2 9449 3 PNL 4104 35.82 0.0 86.0 7958 4 UNL 2 SIPHON 4860 40.65 0.0 82.3 7202 I90500 SEP 28, 2021 9:11 AM SOFTWARE REVISION LEVEL VERSION 329.01 SOFTWARE# 346329-100-B CREATED - 09.01.29.15.44 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD I50500 SEP 28, 2021 9:11 AM SYSTEM TYPE AND LANGUAGE FLAG SYSTEM UNITS U.S. SYSTEM LANGUAGE ENGLISH SYSTEM DATE/TIME FORMAT MON DD YYYY HH:MM:SS xM I50201 SEP 28, 2021 9:11 AM SHIFT TIME 1 : DISABLED I50202 SEP 28, 2021 9:11 AM SHIFT TIME 2 : DISABLED I50203 SEP 28, 2021 9:11 AM SHIFT TIME 3 : DISABLED I50204 SEP 28, 2021 9:11 AM SHIFT TIME 4 : DISABLED I54600 SEP 28, 2021 9:11 AM TANK PER TST NEEDED WRN: DISABLED I54900 SEP 28, 2021 9:11 AM TANK ANN TST NEEDED WRN: DISABLED I55300 SEP 28, 2021 9:11 AM LINE RE-ENABLE METHOD PASS LINE TEST I55600 SEP 28, 2021 9:11 AM LINE PER TST NEEDED WRN: DISABLED I55900 SEP 28, 2021 9:11 AM LINE ANN TST NEEDED WRN: DISABLED I50D00 SEP 28, 2021 9:11 AM PRINT TC VOLUMES ENABLED I50E00 SEP 28, 2021 9:11 AM TEMP COMPENSATION VALUE (DEG F ): 60.0 I60B00 SEP 28, 2021 9:11 AM STICK HEIGHT OFFSET ENABLE STATUS DISABLED I51400 SEP 28, 2021 9:11 AM H-PROTOCOL DATA FORMAT HEIGHT I51A01 SEP 28, 2021 9:11 AM DAYLIGHT SAVING TIME ENABLED ON I51B00 SEP 28, 2021 9:11 AM DAYLIGHT SAVING TIME START DATE MAR WEEK 2 SUN 2:00 AM END DATE NOV WEEK 1 SUN 2:00 AM I51600 SEP 28, 2021 9:11 AM RE-DIRECT LOCAL PRINTOUT DISABLED I50400 SEP 28, 2021 9:11 AM 232 SECURITY CODE PORT SECURITY CODE STATUS 1 000000 DISABLED 2 000000 DISABLED 3 000000 DISABLED 4 000000 DISABLED 5 000000 DISABLED 6 000000 DISABLED I21900 SEP 28, 2021 9:11 AM TANK CHART SECURITY DISABLED I5BD00 SEP 28, 2021 9:11 AM CUSTOM ALARM LABELS DISABLED I56000 SEP 28, 2021 9:11 AM MASS/DENSITY DISABLED I88101 SEP 28, 2021 9:11 AM PORT SETTINGS: COMM BOARD : 1 (RS-232) BAUD RATE : 9600 PARITY : NONE STOP BIT : 1 STOP DATA LENGTH: 8 DATA RS-232 SECURITY CODE : DISABLED I88102 SEP 28, 2021 9:11 AM PORT SETTINGS: COMM BOARD : 2 (RS-232) BAUD RATE : 9600 PARITY : NONE STOP BIT : 1 STOP DATA LENGTH: 8 DATA RS-232 SECURITY CODE : DISABLED I88103 SEP 28, 2021 9:11 AM PORT SETTINGS: COMM BOARD : 3 (EDIM ) RS-232 SECURITY CODE : DISABLED I88104 SEP 28, 2021 9:11 AM I88105 SEP 28, 2021 9:11 AM I88106 SEP 28, 2021 9:11 AM I52000 SEP 28, 2021 9:11 AM RECEIVER AUTO DIAL TYPE & START TIME RCVR LOCATION LABEL DIAL TYPE START TIME 1 ON DATE FEB 28, 2020 DISABLED 2 ON DATE FEB 28, 2020 DISABLED 3 ON DATE FEB 28, 2020 DISABLED 4 ON DATE FEB 28, 2020 DISABLED 5 ON DATE FEB 28, 2020 DISABLED 6 ON DATE FEB 28, 2020 DISABLED 7 ON DATE FEB 28, 2020 DISABLED 8 ON DATE FEB 28, 2020 DISABLED I60100 SEP 28, 2021 9:11 AM TANK CONFIGURATION DEVICE LABEL CONFIGURED 1 UNL ON 2 DIESEL ON 3 PNL ON 4 UNL 2 SIPHON ON I60200 SEP 28, 2021 9:11 AM TANK PRODUCT LABEL TANK PRODUCT LABEL 1 UNL 2 DIESEL 3 PNL 4 UNL 2 SIPHON I60300 SEP 28, 2021 9:11 AM TANK PRODUCT CODE TANK PRODUCT LABEL 1 UNL 1 2 DIESEL 2 3 PNL 3 4 UNL 2 SIPHON 4 I60900 SEP 28, 2021 9:11 AM TANK THERMAL COEFFICIENT TANK PRODUCT LABEL 1 UNL 0.000700 2 DIESEL 0.000450 3 PNL 0.000700 4 UNL 2 SIPHON 0.000700 I60700 SEP 28, 2021 9:11 AM TANK DIAMETER TANK PRODUCT LABEL INCHES 1 UNL 96.00 2 DIESEL 96.00 3 PNL 96.00 4 UNL 2 SIPHON 96.00 I60A00 SEP 28, 2021 9:11 AM TANK FULL VOLUME TANK PRODUCT LABEL TANK PROFILE GALLONS 1 UNL 1 PT 12062 2 DIESEL 1 PT 12062 3 PNL 1 PT 12062 4 UNL 2 SIPHON 1 PT 12062 I60400 SEP 28, 2021 9:11 AM TANK FULL VOLUME TANK PRODUCT LABEL GALLONS 1 UNL 12062 2 DIESEL 12062 3 PNL 12062 4 UNL 2 SIPHON 12062 I60500 SEP 28, 2021 9:11 AM TANK 4 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 UNL 12062 0 0 0 2 DIESEL 12062 0 0 0 3 PNL 12062 0 0 0 4 UNL 2 SIPHON 12062 0 0 0 I60600 SEP 28, 2021 9:11 AM TANK 20 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 UNL 12062 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 DIESEL 12062 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3 PNL 12062 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4 UNL 2 SIPHON 12062 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 I61500 SEP 28, 2021 9:11 AM TANK PRODUCT LABEL METER DATA 1 UNL NO 2 DIESEL NO 3 PNL NO 4 UNL 2 SIPHON NO I62F00 SEP 28, 2021 9:11 AM MAG PROBE FLOAT SIZE TANK PRODUCT LABEL FLOAT SIZE: 1 UNL 4.0 INCHES 2 DIESEL 4.0 INCHES 3 PNL 3.0 INCHES 4 UNL 2 SIPHON 3.0 INCHES I62700 SEP 28, 2021 9:11 AM TANK HIGH WATER WARNING LIMIT TANK PRODUCT LABEL INCHES 1 UNL 2.0 2 DIESEL 2.0 3 PNL 2.0 4 UNL 2 SIPHON 2.0 9999FF1B I62400 SEP 28, 2021 9:11 AM TANK HIGH WATER LEVEL LIMIT TANK PRODUCT LABEL INCHES 1 UNL 3.0 2 DIESEL 3.0 3 PNL 3.0 4 UNL 2 SIPHON 3.0 I62800 SEP 28, 2021 9:11 AM TANK MAXIMUM VOLUME LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 12062 2 DIESEL 12062 3 PNL 12062 4 UNL 2 SIPHON 12062 I62300 SEP 28, 2021 9:11 AM TANK OVERFILL LEVEL LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 10855 2 DIESEL 10855 3 PNL 10855 4 UNL 2 SIPHON 10855 I62200 SEP 28, 2021 9:11 AM TANK HIGH PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 11459 2 DIESEL 11459 3 PNL 11459 4 UNL 2 SIPHON 11459 I62900 SEP 28, 2021 9:11 AM TANK DELIVERY REQUIRED LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 1809 2 DIESEL 1809 3 PNL 1809 4 UNL 2 SIPHON 1809 I62100 SEP 28, 2021 9:11 AM TANK LOW PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 500 2 DIESEL 500 3 PNL 500 4 UNL 2 SIPHON 500 I62600 SEP 28, 2021 9:11 AM TANK LEAK ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 99 2 DIESEL 99 3 PNL 99 4 UNL 2 SIPHON 99 I62500 SEP 28, 2021 9:11 AM TANK SUDDEN LOSS LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 99 2 DIESEL 99 3 PNL 99 4 UNL 2 SIPHON 99 I60800 SEP 28, 2021 9:11 AM TANK TILT TANK PRODUCT LABEL INCHES 1 UNL 4.50 2 DIESEL -3.00 3 PNL 4.30 4 UNL 2 SIPHON 4.44 I60B00 SEP 28, 2021 9:11 AM STICK HEIGHT OFFSET ENABLE STATUS DISABLED I60C00 SEP 28, 2021 9:11 AM TANK STICK HEIGHT OFFSET TANK PRODUCT LABEL INCHES 1 UNL 0.00 2 DIESEL 0.00 3 PNL 0.00 4 UNL 2 SIPHON 0.00 I61200 SEP 28, 2021 9:11 AM TANK MANIFOLDED PARTNERS TANK PRODUCT LABEL SIPHON MANIFOLDED TANKS LINE MANIFOLDED TANKS 1 UNL NONE NONE 2 DIESEL NONE NONE 3 PNL NONE NONE 4 UNL 2 SIPHON NONE NONE I63600 SEP 28, 2021 9:11 AM PERIODIC LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 UNL 1220 2 DIESEL 120 3 PNL 120 4 UNL 2 SIPHON 120 I62A00 SEP 28, 2021 9:11 AM ANNUAL LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 UNL 0 2 DIESEL 0 3 PNL 0 4 UNL 2 SIPHON 120 I62C00 SEP 28, 2021 9:11 AM TANK PERIODIC TEST TYPE TANK PRODUCT LABEL PERIODIC TEST TYPE 1 UNL STANDARD 2 DIESEL STANDARD 3 PNL STANDARD 4 UNL 2 SIPHON STANDARD I62D00 SEP 28, 2021 9:11 AM TANK LEAK TEST FAIL ALARMS TANK PRODUCT LABEL 1 UNL GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED 2 DIESEL GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 3 PNL GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 4 UNL 2 SIPHON GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED I63100 SEP 28, 2021 9:11 AM TANK LEAK TEST AVERAGING TANK PRODUCT LABEL ANNUAL PERIODIC 1 UNL OFF OFF 2 DIESEL OFF OFF 3 PNL OFF OFF 4 UNL 2 SIPHON OFF OFF I63000 SEP 28, 2021 9:11 AM IN-TANK LEAK TEST NOTIFY TANK PRODUCT LABEL TANK TEST NOTIFY: 1 UNL OFF 2 DIESEL OFF 3 PNL OFF 4 UNL 2 SIPHON OFF I63200 SEP 28, 2021 9:11 AM TANK TEST SIPHON BREAK TANK PRODUCT LABEL SIPHON BREAK 1 UNL OFF 2 DIESEL OFF 3 PNL OFF 4 UNL 2 SIPHON OFF I61000 SEP 28, 2021 9:11 AM TANK DELIVERY DELAY TANK PRODUCT LABEL 1 UNL 1 2 DIESEL 1 3 PNL 1 4 UNL 2 SIPHON 1 I63A00 SEP 28, 2021 9:11 AM LOW LEVEL PUMP THRESHOLD FOR SEQUENTIAL LINE MANIFOLD TANK PRODUCT LABEL PUMP THRESHOLD 1 UNL 10.00% 2 DIESEL 10.00% 3 PNL 10.00% 4 UNL 2 SIPHON 10.00% I61100 SEP 28, 2021 9:11 AM LEAK TEST METHOD - - - - - - - - - - - - TEST ON DATE : TANK 1 MAR 19, 2009 START TIME : DISABLED TEST RATE :0.20 GAL/HR DURATION : 2 HOURS TST EARLY STOP:DISABLED TEST ON DATE : TANK 2 MAR 19, 2009 START TIME : DISABLED TEST RATE :0.20 GAL/HR DURATION : 2 HOURS TST EARLY STOP:DISABLED TEST ON DATE : TANK 3 MAR 19, 2009 START TIME : DISABLED TEST RATE :0.20 GAL/HR DURATION : 2 HOURS TST EARLY STOP:DISABLED TEST ON DATE : TANK 4 MAR 19, 2009 START TIME : DISABLED TEST RATE :0.20 GAL/HR DURATION : 2 HOURS TST EARLY STOP:DISABLED I61300 SEP 28, 2021 9:11 AM CSLD PROBABLITY OF DETECTION I61400 SEP 28, 2021 9:11 AM CSLD CLIMATE FACTOR I61600 SEP 28, 2021 9:11 AM TANK PRODUCT LABEL CAL UPDATE 1 UNL IMMEDIATE 2 DIESEL IMMEDIATE 3 PNL IMMEDIATE 4 UNL 2 SIPHON IMMEDIATE I61A00 SEP 28, 2021 9:11 AM IN-TANK LEAK TEST EARLY STOP TANK PRODUCT LABEL TST EARLY STOP: 1 UNL DISABLED 2 DIESEL DISABLED 3 PNL DISABLED 4 UNL 2 SIPHON DISABLED I61B00 SEP 28, 2021 9:11 AM IN-TANK LEAK GROSS TEST AUTO-CONFIRM I61C00 SEP 28, 2021 9:11 AM CSLD REPORT ONLY I62B00 SEP 28, 2021 9:11 AM TANK LAST ANNUAL TEST TANK PRODUCT LABEL DATE 1 UNL ??? 0, 0 2 DIESEL ??? 0, 0 3 PNL ??? 0, 0 4 UNL 2 SIPHON ??? 0, 0 I63300 SEP 28, 2021 9:11 AM LEAK TEST REPORT FORMAT: NORMAL I63400 SEP 28, 2021 9:11 AM RECONCILIATION WARNING LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 0 2 DIESEL 0 3 PNL 0 4 UNL 2 SIPHON 0 I63500 SEP 28, 2021 9:11 AM RECONCILIATION ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 1 2 DIESEL 1 3 PNL 1 4 UNL 2 SIPHON 1 I63900 SEP 28, 2021 9:11 AM ACCU CHART END SHAPE FACTOR TANK PRODUCT LABEL 1 UNL END FACTOR: NONE 2 DIESEL END FACTOR: NONE 3 PNL END FACTOR: NONE 4 UNL 2 SIPHON END FACTOR: NONE I78000 SEP 28, 2021 9:11 AM I77700 SEP 28, 2021 9:11 AM I77800 SEP 28, 2021 9:11 AM I78C00 SEP 28, 2021 9:11 AM I78300 SEP 28, 2021 9:11 AM I78F00 SEP 28, 2021 9:11 AM I78700 SEP 28, 2021 9:11 AM I70200 SEP 28, 2021 9:11 AM LIQUID LABEL DEVICE LABEL 1 UNL 1 STP 2 UNL1 ANN 3 DIESEL STP 4 DIESEL ANN 5 PNL STP 6 PNL ANN 7 UNL2 SIPON STP 8 UNL2 ANN 9 DISP 1-2 10 DISP 3-4 11 DISP 5-6 12 DISP 7-8 13 TRAN NO. 14 TRAN SO. 15 16 I70300 SEP 28, 2021 9:12 AM LIQUID TYPE SENSOR LOCATION TYPE 1 UNL 1 STP TRI-STATE (SINGLE FLOAT) 2 UNL1 ANN TRI-STATE (SINGLE FLOAT) 3 DIESEL STP TRI-STATE (SINGLE FLOAT) 4 DIESEL ANN TRI-STATE (SINGLE FLOAT) 5 PNL STP TRI-STATE (SINGLE FLOAT) 6 PNL ANN TRI-STATE (SINGLE FLOAT) 7 UNL2 SIPON STP TRI-STATE (SINGLE FLOAT) 8 UNL2 ANN TRI-STATE (SINGLE FLOAT) 9 DISP 1-2 TRI-STATE (SINGLE FLOAT) 10 DISP 3-4 TRI-STATE (SINGLE FLOAT) 11 DISP 5-6 TRI-STATE (SINGLE FLOAT) 12 DISP 7-8 TRI-STATE (SINGLE FLOAT) 13 TRAN NO. TRI-STATE (SINGLE FLOAT) 14 TRAN SO. TRI-STATE (SINGLE FLOAT) 15 TRI-STATE (SINGLE FLOAT) 16 TRI-STATE (SINGLE FLOAT) I70400 SEP 28, 2021 9:12 AM LIQUID CATEGORY SENSOR LOCATION CATEGORY 1 UNL 1 STP STP SUMP 2 UNL1 ANN ANNULAR SPACE 3 DIESEL STP STP SUMP 4 DIESEL ANN ANNULAR SPACE 5 PNL STP STP SUMP 6 PNL ANN ANNULAR SPACE 7 UNL2 SIPON STP STP SUMP 8 UNL2 ANN ANNULAR SPACE 9 DISP 1-2 DISPENSER PAN 10 DISP 3-4 DISPENSER PAN 11 DISP 5-6 DISPENSER PAN 12 DISP 7-8 DISPENSER PAN 13 TRAN NO. PIPING SUMP 14 TRAN SO. PIPING SUMP 15 OTHER SENSORS 16 OTHER SENSORS I74200 SEP 28, 2021 9:12 AM I74300 SEP 28, 2021 9:12 AM I74400 SEP 28, 2021 9:12 AM I74700 SEP 28, 2021 9:12 AM I74800 SEP 28, 2021 9:12 AM I74900 SEP 28, 2021 9:12 AM I7BC00 SEP 28, 2021 9:12 AM I80200 SEP 28, 2021 9:12 AM I80300 SEP 28, 2021 9:12 AM I80400 SEP 28, 2021 9:12 AM I80700 SEP 28, 2021 9:12 AM RELAY LABEL DEVICE LABEL 1 UNL 1 2 DIESEL 3 PNL 4 5 OVERFILL ALARM 6 7 8 I80900 SEP 28, 2021 9:12 AM RELAY ORIENTATION RELAY DESIGNATION ORIENTATION 1 UNL 1 NORMALLY OPEN 2 DIESEL NORMALLY CLOSED 3 PNL NORMALLY OPEN 4 NORMALLY OPEN 5 OVERFILL ALARM NORMALLY OPEN 6 NORMALLY OPEN 7 NORMALLY OPEN 8 NORMALLY OPEN I80B00 SEP 28, 2021 9:12 AM RELAY TANK ASSIGNMENT RELAY DESIGNATION TANK 1 UNL 1 1 2 DIESEL 2 3 PNL 3 4 NONE 5 OVERFILL ALARM NONE 6 NONE 7 NONE 8 NONE I80A00 SEP 28, 2021 9:12 AM RELAY TYPE RELAY DESIGNATION TYPE 1 UNL 1 PUMP CONTROL OUTPUT 2 DIESEL STANDARD 3 PNL PUMP CONTROL OUTPUT 4 STANDARD 5 OVERFILL ALARM STANDARD 6 STANDARD 7 STANDARD 8 STANDARD I80C00 SEP 28, 2021 9:12 AM I80800 SEP 28, 2021 9:12 AM RELAY SETUP REPORT R 1:UNL 1 TYPE: PUMP CONTROL OUTPUT TANK #: 1 LIQUID SENSOR ALMS L 1:FUEL ALARM L 7:FUEL ALARM L 9:FUEL ALARM L10:FUEL ALARM L11:FUEL ALARM L12:FUEL ALARM L 1:SENSOR OUT ALARM L 7:SENSOR OUT ALARM L 9:SENSOR OUT ALARM L10:SENSOR OUT ALARM L11:SENSOR OUT ALARM L12:SENSOR OUT ALARM L 1:SHORT ALARM L 7:SHORT ALARM L 9:SHORT ALARM L10:SHORT ALARM L11:SHORT ALARM L12:SHORT ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD VP PRES FAIL ISD VP STATUS FAIL ISD HOSE ALARMS ALL:GROSS COLLECT FAIL ALL:DEGRD COLLECT FAIL ALL:FLOW COLLECT FAIL R 2:DIESEL TYPE: STANDARD NORMALLY CLOSED TANK #: 2 LIQUID SENSOR ALMS L 3:FUEL ALARM L 9:FUEL ALARM L11:FUEL ALARM L13:FUEL ALARM L14:FUEL ALARM L 3:SENSOR OUT ALARM L 9:SENSOR OUT ALARM L11:SENSOR OUT ALARM L13:SENSOR OUT ALARM L14:SENSOR OUT ALARM L 3:SHORT ALARM L 4:SHORT ALARM L 9:SHORT ALARM L11:SHORT ALARM L13:SHORT ALARM L14:SHORT ALARM R 3:PNL TYPE: PUMP CONTROL OUTPUT TANK #: 3 LIQUID SENSOR ALMS L 5:FUEL ALARM L 9:FUEL ALARM L10:FUEL ALARM L11:FUEL ALARM L12:FUEL ALARM L 5:SENSOR OUT ALARM L 9:SENSOR OUT ALARM L10:SENSOR OUT ALARM L11:SENSOR OUT ALARM L12:SENSOR OUT ALARM ISD HOSE ALARMS ALL:GROSS COLLECT FAIL ALL:DEGRD COLLECT FAIL ALL:FLOW COLLECT FAIL R 4: TYPE: STANDARD NORMALLY OPEN TANK #: NONE - NO ALARM ASSIGNMENTS - R 5:OVERFILL ALARM TYPE: STANDARD NORMALLY OPEN TANK #: NONE IN-TANK ALARMS ALL:OVERFILL ALARM ALL:HIGH PRODUCT ALARM ALL:MAX PRODUCT ALARM R 6: TYPE: STANDARD NORMALLY OPEN TANK #: NONE - NO ALARM ASSIGNMENTS - R 7: TYPE: STANDARD NORMALLY OPEN TANK #: NONE - NO ALARM ASSIGNMENTS - R 8: TYPE: STANDARD NORMALLY OPEN TANK #: NONE - NO ALARM ASSIGNMENTS - I79000 SEP 28, 2021 9:12 AM EDIM:1 VR:349634-003-C TD:06.05.11.11.15 I79100 SEP 28, 2021 9:12 AM I72300 SEP 28, 2021 9:12 AM FASTRIP 562 MING-CHESTER BAKERSFIELD CA 661-397-8606 SMARTSENSOR ASSIGNMENT DEVICE LABEL CATEGORY 01 V.P.SENSOR DISP 3-4 VAPOR PRESSURE 02 F.M.DISP 1-2 AIR FLOW METER 03 F.M.DISP 3-4 AIR FLOW METER 04 F.M.DISP 5-6 AIR FLOW METER 05 F.M.DISP 7-8 AIR FLOW METER 06 UNKNOWN 07 UNKNOWN 08 UNKNOWN 09 UNKNOWN 10 UNKNOWN 11 UNKNOWN 12 UNKNOWN 13 UNKNOWN 14 UNKNOWN 15 UNKNOWN 16 UNKNOWN 17 UNKNOWN 18 UNKNOWN 19 UNKNOWN 20 UNKNOWN 21 UNKNOWN 22 UNKNOWN 23 UNKNOWN 24 UNKNOWN 25 UNKNOWN 26 UNKNOWN 27 UNKNOWN 28 UNKNOWN 29 UNKNOWN 30 UNKNOWN 31 UNKNOWN 32 UNKNOWN 33 UNKNOWN 34 UNKNOWN 35 UNKNOWN 36 UNKNOWN 37 UNKNOWN 38 UNKNOWN 39 UNKNOWN 40 UNKNOWN IV4E00 SEP 28, 2021 9:12 AM FASTRIP 562 MING-CHESTER BAKERSFIELD CA 661-397-8606 EVR/ISD SETUP TYPE: VACUUM ASSIST VACUUM ASSIST TYPE: HEALY VAC IV4F00 SEP 28, 2021 9:12 AM FASTRIP 562 MING-CHESTER BAKERSFIELD CA 661-397-8606 NOZZLE A/L RANGE A/L RATIO: 0.95 - 1.15 IV4000 SEP 28, 2021 9:12 AM FASTRIP 562 MING-CHESTER BAKERSFIELD CA 661-397-8606 VAPOR PROCESSOR TYPE NONE IV4700 SEP 28, 2021 9:12 AM FASTRIP 562 MING-CHESTER BAKERSFIELD CA 661-397-8606 ASSESSMENT TIME START TIME: 11:48 AM TIME DELAY MINUTES: 1 IV5200 SEP 28, 2021 9:12 AM FASTRIP 562 MING-CHESTER BAKERSFIELD CA 661-397-8606 ACCEPT HIGH ORVR: NO IV4A00 SEP 28, 2021 9:12 AM FASTRIP 562 MING-CHESTER BAKERSFIELD CA 661-397-8606 ISD HOSE TABLE HOSE FP FP AFM HOSE ID ID LABEL ID LABEL 01 01 01 01 BLEND3 02 02 02 01 BLEND3 03 03 03 02 BLEND3 04 04 04 02 BLEND3 05 05 05 03 BLEND3 06 06 06 03 BLEND3 07 07 07 04 BLEND3 08 08 08 04 BLEND3 IV4B00 SEP 28, 2021 9:12 AM FASTRIP 562 MING-CHESTER BAKERSFIELD CA 661-397-8606 PRODUCT/HOSE MAP TABLE FP AFID M1/H1 M2/H2 M3/H3 M4/H4 01 01 02/01 03/01 09/01 xx/xx 02 01 02/02 03/02 09/02 xx/xx 03 02 02/03 03/03 09/03 xx/xx 04 02 02/04 03/04 09/04 xx/xx 05 03 02/05 03/05 09/05 xx/xx 06 03 02/06 03/06 09/06 xx/xx 07 04 02/07 03/07 09/07 xx/xx 08 04 02/08 03/08 09/08 xx/xx IV4900 SEP 28, 2021 9:12 AM FASTRIP 562 MING-CHESTER BAKERSFIELD CA 661-397-8606 LABEL TABLE ID LABEL 01 UNASSIGNED 02 BLEND3 03 REGULAR 04 MID GRADE 05 PREMIUM 06 GOLD 07 BRONZE 08 SILVER 09 BLEND2 10 BLEND4 IV1000 SEP 28, 2021 9:12 AM ISD VERSION: 01.02 ALARM HISTORY BEFORE Responses Received: I10200 SEP 28, 2021 9:13 AM FASTRIP 562 MING-CHESTER BAKERSFIELD CA 661-397-8606 SYSTEM CONFIGURATION SLOT BOARD TYPE POWER ON RESET CURRENT 1 7SMARTSENSOR BD 508079 508177 2 4 PROBE / G.T. 161504 161508 3 INTERSTITIAL BD 202172 202307 4 INTERSTITIAL BD 202533 202524 5 UNUSED 4812041 4604171 6 UNUSED 4809760 4602113 7 UNUSED 4811310 4597708 8 UNUSED 4810181 4599634 9 STP SENSE BOARD 33224 33227 10 RELAY BOARD 14888 14909 11 RELAY BOARD 14955 14998 12 UNUSED 4813085 4603777 13 UNUSED 4809830 4598354 14 UNUSED 4811668 4600678 15 UNUSED 4807351 4594923 16 UNUSED 4811447 4599616 COMM 1 RS232 SERIAL BD 14932 14954 COMM 2 RS232 SERIAL BD 14977 14998 COMM 3 ELEC DISP INT. 101186 101170 COMM 4 UNUSED 4810118 4600147 COMM 5 UNUSED 4811956 4601497 COMM 6 UNUSED 4806399 4598310 I90200 SEP 28, 2021 9:13 AM SOFTWARE REVISION LEVEL VERSION 329.01 SOFTWARE# 346329-100-B CREATED - 09.01.29.15.44 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD I11100 SEP 28, 2021 9:13 AM FASTRIP 562 MING-CHESTER BAKERSFIELD CA 661-397-8606 PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME L 4 ANNULAR DIESEL ANN FUEL ALARM CLEAR 9-13-21 2:17PM L 8 ANNULAR UNL2 ANN SENSOR OUT ALARM CLEAR 9-13-21 2:13PM L 7 STP SUMP UNL2 SIPON STP SENSOR OUT ALARM CLEAR 9-13-21 2:13PM L 6 ANNULAR PNL ANN SENSOR OUT ALARM CLEAR 9-13-21 2:13PM L 4 ANNULAR DIESEL ANN SENSOR OUT ALARM CLEAR 9-13-21 2:13PM L 4 ANNULAR DIESEL ANN FUEL ALARM ALARM 9-13-21 2:13PM L 3 STP SUMP DIESEL STP SENSOR OUT ALARM CLEAR 9-13-21 2:13PM L 5 STP SUMP PNL STP SENSOR OUT ALARM CLEAR 9-13-21 2:13PM L 2 ANNULAR UNL1 ANN SENSOR OUT ALARM CLEAR 9-13-21 2:13PM L14 PIPE TRAN SO. SENSOR OUT ALARM CLEAR 9-13-21 2:13PM L10 DISP PAN DISP 3-4 SENSOR OUT ALARM CLEAR 9-13-21 2:13PM L 9 DISP PAN DISP 1-2 SENSOR OUT ALARM CLEAR 9-13-21 2:13PM L12 DISP PAN DISP 7-8 SENSOR OUT ALARM CLEAR 9-13-21 2:13PM L 1 STP SUMP UNL 1 STP SENSOR OUT ALARM CLEAR 9-13-21 2:13PM L13 PIPE TRAN NO. SENSOR OUT ALARM CLEAR 9-13-21 2:13PM L11 DISP PAN DISP 5-6 SENSOR OUT ALARM CLEAR 9-13-21 2:13PM L 8 ANNULAR UNL2 ANN SENSOR OUT ALARM ALARM 9-13-21 2:13PM L 7 STP SUMP UNL2 SIPON STP SENSOR OUT ALARM ALARM 9-13-21 2:13PM L12 DISP PAN DISP 7-8 SENSOR OUT ALARM ALARM 9-13-21 2:13PM L 6 ANNULAR PNL ANN SENSOR OUT ALARM ALARM 9-13-21 2:13PM L11 DISP PAN DISP 5-6 SENSOR OUT ALARM ALARM 9-13-21 2:13PM L 3 STP SUMP DIESEL STP SENSOR OUT ALARM ALARM 9-13-21 2:13PM L 4 ANNULAR DIESEL ANN SENSOR OUT ALARM ALARM 9-13-21 2:13PM L 4 ANNULAR DIESEL ANN FUEL ALARM CLEAR 9-13-21 2:13PM L 5 STP SUMP PNL STP SENSOR OUT ALARM ALARM 9-13-21 2:13PM L10 DISP PAN DISP 3-4 SENSOR OUT ALARM ALARM 9-13-21 2:13PM L 2 ANNULAR UNL1 ANN SENSOR OUT ALARM ALARM 9-13-21 2:13PM L 9 DISP PAN DISP 1-2 SENSOR OUT ALARM ALARM 9-13-21 2:13PM L 1 STP SUMP UNL 1 STP SENSOR OUT ALARM ALARM 9-13-21 2:13PM L14 PIPE TRAN SO. SENSOR OUT ALARM ALARM 9-13-21 2:13PM L13 PIPE TRAN NO. SENSOR OUT ALARM ALARM 9-13-21 2:12PM L13 PIPE TRAN NO. FUEL ALARM CLEAR 9-13-21 2:10PM L13 PIPE TRAN NO. FUEL ALARM ALARM 9-13-21 2:10PM L10 DISP PAN DISP 3-4 FUEL ALARM CLEAR 9-13-21 2:10PM L10 DISP PAN DISP 3-4 FUEL ALARM ALARM 9-13-21 2:09PM L 9 DISP PAN DISP 1-2 FUEL ALARM CLEAR 9-13-21 2:08PM L 9 DISP PAN DISP 1-2 FUEL ALARM ALARM 9-13-21 2:06PM L11 DISP PAN DISP 5-6 FUEL ALARM CLEAR 9-13-21 2:04PM L11 DISP PAN DISP 5-6 FUEL ALARM ALARM 9-13-21 2:03PM L14 PIPE TRAN SO. FUEL ALARM CLEAR 9-13-21 2:03PM L14 PIPE TRAN SO. FUEL ALARM ALARM 9-13-21 2:02PM L12 DISP PAN DISP 7-8 FUEL ALARM CLEAR 9-13-21 2:01PM L12 DISP PAN DISP 7-8 FUEL ALARM ALARM 9-13-21 2:01PM L 6 ANNULAR PNL ANN FUEL ALARM CLEAR 9-13-21 1:58PM L 6 ANNULAR PNL ANN FUEL ALARM ALARM 9-13-21 1:58PM L 4 ANNULAR DIESEL ANN FUEL ALARM ALARM 9-13-21 1:57PM L14 PIPE TRAN SO. FUEL ALARM CLEAR 9-13-21 1:57PM L 4 ANNULAR DIESEL ANN FUEL ALARM CLEAR 9-13-21 1:57PM L14 PIPE TRAN SO. FUEL ALARM ALARM 9-13-21 1:57PM L 4 ANNULAR DIESEL ANN FUEL ALARM ALARM 9-13-21 1:57PM I11200 SEP 28, 2021 9:13 AM FASTRIP 562 MING-CHESTER BAKERSFIELD CA 661-397-8606 NON-PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME SYSTEM PRINTER ERROR CLEAR 8-30-21 4:21PM SYSTEM PAPER OUT CLEAR 8-30-21 4:21PM SYSTEM PRINTER ERROR ALARM 8-30-21 4:18PM SYSTEM PAPER OUT ALARM 8-30-21 4:18PM T 2 TANK DIESEL DELIVERY NEEDED CLEAR 8-15-21 1:57AM T 2 TANK DIESEL DELIVERY NEEDED ALARM 8-14-21 11:50AM SYSTEM PRINTER ERROR CLEAR 8-03-21 2:43PM SYSTEM PAPER OUT CLEAR 8-03-21 2:43PM SYSTEM PRINTER ERROR ALARM 8-03-21 2:41PM SYSTEM PAPER OUT ALARM 8-03-21 2:41PM T 2 TANK DIESEL DELIVERY NEEDED CLEAR 8-01-21 5:06AM T 2 TANK DIESEL DELIVERY NEEDED ALARM 7-31-21 8:24PM h 4 OTHER FP4: BLEND3 DEGRD COLLECT WARN CLEAR 7-27-21 11:51AM h 4 OTHER FP4: BLEND3 DEGRD COLLECT WARN ALARM 7-27-21 11:49AM SYSTEM PRINTER ERROR CLEAR 7-18-21 12:32PM SYSTEM PAPER OUT CLEAR 7-18-21 12:32PM SYSTEM PRINTER ERROR ALARM 7-18-21 12:30PM SYSTEM PAPER OUT ALARM 7-18-21 12:30PM OTHER ISD VAPOR LEAK WARN CLEAR 7-13-21 11:48AM OTHER ISD VAPOR LEAK WARN ALARM 7-12-21 11:49AM SYSTEM PRINTER ERROR CLEAR 6-27-21 3:11AM SYSTEM PAPER OUT CLEAR 6-27-21 3:11AM SYSTEM PRINTER ERROR ALARM 6-27-21 3:08AM SYSTEM PAPER OUT ALARM 6-27-21 3:08AM h 7 OTHER FP7: BLEND3 DEGRD COLLECT WARN CLEAR 6-18-21 11:48AM h 7 OTHER FP7: BLEND3 DEGRD COLLECT WARN ALARM 6-11-21 11:49AM OTHER ISD VAPOR LEAK WARN CLEAR 6-08-21 11:48AM OTHER ISD VAPOR LEAK WARN ALARM 6-07-21 11:49AM SYSTEM PRINTER ERROR CLEAR 6-06-21 1:25PM SYSTEM PAPER OUT CLEAR 6-06-21 1:25PM SYSTEM PRINTER ERROR ALARM 6-06-21 1:25PM SYSTEM PAPER OUT ALARM 6-06-21 1:25PM SYSTEM PRINTER ERROR CLEAR 6-06-21 12:23PM SYSTEM PAPER OUT CLEAR 6-06-21 12:23PM SYSTEM PRINTER ERROR ALARM 6-06-21 12:21PM SYSTEM PAPER OUT ALARM 6-06-21 12:21PM h 7 OTHER FP7: BLEND3 DEGRD COLLECT WARN CLEAR 5-26-21 11:48AM h 7 OTHER FP7: BLEND3 DEGRD COLLECT WARN ALARM 5-25-21 11:49AM h 2 OTHER FP2: BLEND3 DEGRD COLLECT WARN CLEAR 5-19-21 11:48AM h 2 OTHER FP2: BLEND3 DEGRD COLLECT WARN ALARM 5-18-21 11:49AM h 1 OTHER FP1: BLEND3 DEGRD COLLECT WARN CLEAR 5-04-21 11:58AM h 1 OTHER FP1: BLEND3 DEGRD COLLECT WARN ALARM 5-02-21 11:49AM T 4 TANK UNL 2 SIPHON DELIVERY NEEDED CLEAR 4-19-21 12:58AM T 4 TANK UNL 2 SIPHON DELIVERY NEEDED ALARM 4-18-21 10:24PM h 6 OTHER FP6: BLEND3 GROSS COLLECT WARN CLEAR 4-16-21 5:28PM h 5 OTHER FP5: BLEND3 GROSS COLLECT WARN CLEAR 4-16-21 5:28PM h 6 OTHER FP6: BLEND3 GROSS COLLECT WARN ALARM 4-16-21 11:49AM h 5 OTHER FP5: BLEND3 GROSS COLLECT WARN ALARM 4-16-21 11:49AM h 6 OTHER FP6: BLEND3 GROSS COLLECT WARN CLEAR 4-14-21 10:14AM h 6 OTHER FP6: BLEND3 GROSS COLLECT WARN ALARM 4-13-21 11:49AM I20600 SEP 28, 2021 9:14 AM FASTRIP 562 MING-CHESTER BAKERSFIELD CA 661-397-8606 TANK ALARM HISTORY TANK 1 UNL SETUP DATA WARNING JAN 29, 2009 8:13 AM OVERFILL ALARM SEP 8, 2021 9:25 PM AUG 7, 2021 7:13 AM AUG 4, 2021 3:36 PM SUDDEN LOSS ALARM JUL 25, 2021 3:26 AM JUL 25, 2021 2:38 AM JUL 25, 2021 2:06 AM HIGH PRODUCT ALARM SEP 8, 2020 11:51 AM JUL 9, 2019 5:06 PM MAY 12, 2019 6:37 AM PROBE OUT SEP 8, 2020 11:52 AM SEP 8, 2020 11:50 AM NOV 28, 2018 12:07 PM DELIVERY NEEDED APR 27, 2020 10:41 AM LOW TEMP WARNING SEP 8, 2020 11:53 AM NOV 28, 2018 12:07 PM TANK 2 DIESEL HIGH WATER ALARM SEP 1, 2020 12:00 PM OVERFILL ALARM SEP 8, 2020 11:32 AM SEP 1, 2020 12:19 PM NOV 28, 2018 11:54 AM LOW PRODUCT ALARM SEP 8, 2020 11:33 AM SEP 1, 2020 11:53 AM INVALID FUEL LEVEL SEP 8, 2020 11:33 AM SEP 8, 2020 11:31 AM SEP 2, 2020 9:16 AM PROBE OUT SEP 8, 2020 11:33 AM SEP 8, 2020 11:30 AM SEP 1, 2020 5:21 PM HIGH WATER WARNING SEP 1, 2020 12:00 PM DELIVERY NEEDED AUG 14, 2021 11:50 AM JUL 31, 2021 8:24 PM JAN 14, 2021 8:29 AM LOW TEMP WARNING NOV 28, 2018 11:56 AM TANK 3 PNL HIGH WATER ALARM SEP 1, 2020 5:26 PM OVERFILL ALARM SEP 8, 2020 11:28 AM SEP 1, 2020 12:33 PM NOV 28, 2018 11:58 AM SUDDEN LOSS ALARM SEP 8, 2020 11:26 AM SEP 8, 2020 10:43 AM SEP 1, 2020 11:50 AM HIGH PRODUCT ALARM SEP 8, 2020 11:28 AM SEP 1, 2020 5:27 PM SEP 1, 2020 5:23 PM INVALID FUEL LEVEL SEP 8, 2020 11:29 AM SEP 1, 2020 5:35 PM MAR 5, 2020 12:03 PM PROBE OUT SEP 8, 2020 11:28 AM SEP 8, 2020 11:26 AM SEP 1, 2020 5:38 PM HIGH WATER WARNING SEP 1, 2020 5:26 PM DELIVERY NEEDED SEP 8, 2020 11:29 AM SEP 8, 2020 11:27 AM SEP 8, 2020 10:43 AM MAX PRODUCT ALARM SEP 1, 2020 5:27 PM SEP 1, 2020 5:23 PM LOW TEMP WARNING SEP 1, 2020 5:39 PM NOV 28, 2018 11:59 AM SEP 10, 2018 10:05 AM TANK 4 UNL 2 SIPHON OVERFILL ALARM SEP 8, 2021 9:20 PM NOV 27, 2020 11:57 AM SEP 8, 2020 11:56 AM HIGH PRODUCT ALARM SEP 8, 2020 11:56 AM PROBE OUT SEP 8, 2020 11:57 AM SEP 8, 2020 11:54 AM JAN 22, 2019 11:39 AM DELIVERY NEEDED APR 18, 2021 10:24 PM JAN 17, 2019 2:31 PM LOW TEMP WARNING NOV 28, 2018 12:14 PM I38200 SEP 28, 2021 9:14 AM I30200 SEP 28, 2021 9:14 AM FASTRIP 562 MING-CHESTER BAKERSFIELD CA 661-397-8606 LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 UNL 1 STP SEP 13, 2021 2:13 PM SENSOR OUT ALARM SEP 13, 2021 1:53 PM FUEL ALARM SEP 8, 2020 9:54 AM SENSOR OUT ALARM 2 UNL1 ANN SEP 13, 2021 2:13 PM SENSOR OUT ALARM SEP 13, 2021 1:56 PM FUEL ALARM SEP 8, 2020 9:54 AM SENSOR OUT ALARM 3 DIESEL STP SEP 13, 2021 2:13 PM SENSOR OUT ALARM SEP 13, 2021 1:54 PM FUEL ALARM JAN 7, 2021 3:20 AM FUEL ALARM 4 DIESEL ANN SEP 13, 2021 2:13 PM FUEL ALARM SEP 13, 2021 2:13 PM SENSOR OUT ALARM SEP 13, 2021 1:57 PM FUEL ALARM 5 PNL STP SEP 13, 2021 2:13 PM SENSOR OUT ALARM SEP 13, 2021 1:54 PM FUEL ALARM AUG 12, 2021 4:02 AM FUEL ALARM 6 PNL ANN SEP 13, 2021 2:13 PM SENSOR OUT ALARM SEP 13, 2021 1:58 PM FUEL ALARM DEC 28, 2020 1:22 PM SENSOR OUT ALARM 7 UNL2 SIPON STP SEP 13, 2021 2:13 PM SENSOR OUT ALARM SEP 13, 2021 1:51 PM FUEL ALARM SEP 8, 2020 9:54 AM SENSOR OUT ALARM 8 UNL2 ANN SEP 13, 2021 2:13 PM SENSOR OUT ALARM SEP 13, 2021 1:56 PM FUEL ALARM SEP 8, 2020 9:54 AM SENSOR OUT ALARM 9 DISP 1-2 SEP 13, 2021 2:13 PM SENSOR OUT ALARM SEP 13, 2021 2:06 PM FUEL ALARM SEP 8, 2020 9:54 AM SENSOR OUT ALARM 10 DISP 3-4 SEP 13, 2021 2:13 PM SENSOR OUT ALARM SEP 13, 2021 2:09 PM FUEL ALARM SEP 8, 2020 9:54 AM SENSOR OUT ALARM 11 DISP 5-6 SEP 13, 2021 2:13 PM SENSOR OUT ALARM SEP 13, 2021 2:03 PM FUEL ALARM SEP 8, 2020 9:54 AM SENSOR OUT ALARM 12 DISP 7-8 SEP 13, 2021 2:13 PM SENSOR OUT ALARM SEP 13, 2021 2:01 PM FUEL ALARM SEP 8, 2020 9:54 AM SENSOR OUT ALARM 13 TRAN NO. SEP 13, 2021 2:12 PM SENSOR OUT ALARM SEP 13, 2021 2:10 PM FUEL ALARM JUL 9, 2021 3:17 PM FUEL ALARM 14 TRAN SO. SEP 13, 2021 2:13 PM SENSOR OUT ALARM SEP 13, 2021 2:02 PM FUEL ALARM SEP 13, 2021 1:57 PM FUEL ALARM I31600 SEP 28, 2021 9:14 AM FASTRIP 562 MING-CHESTER BAKERSFIELD CA 661-397-8606 SMART SENSOR ALARM HISTORY REPORT SENSOR LOCATION 1 V.P.SENSOR DISP 3-4 2 F.M.DISP 1-2 3 F.M.DISP 3-4 4 F.M.DISP 5-6 5 F.M.DISP 7-8 FEB 22, 2020 8:22 AM COMMUNICATION ALARM FEB 16, 2020 8:41 AM COMMUNICATION ALARM DEC 22, 2019 3:33 PM COMMUNICATION ALARM I40200 SEP 28, 2021 9:14 AM I40300 SEP 28, 2021 9:14 AM I34200 SEP 28, 2021 9:14 AM I34700 SEP 28, 2021 9:14 AM IV0100 SEP 28, 2021 9:14 AM FASTRIP 562 MING-CHESTER BAKERSFIELD CA 661-397-8606 ISD ALARM STATUS REPORT EVR TYPE: VACUUM ASSIST ISD TYPE: 01.02 VAPOR PROCESSOR TYPE: NONE OVERALL STATUS :PASS EVR VAPOR COLLECTION :PASS EVR VAPOR CONTAINMENT :PASS ISD MONITOR UP-TIME :100% STAGE I TRANSFERS: 0 of 0 NOTEST EVR/ISD PASS TIME :100% WARNING ALARMS DATE TIME DESCRIPTION READING VALUE 21-07-27 11:49:09 A/L RATIO DEGRADATION FP 4 BLEND3 0.00 21-07-12 11:49:09 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 9.19 21-06-17 11:49:09 A/L RATIO DEGRADATION FP 7 BLEND3 0.79 21-06-16 11:49:09 A/L RATIO DEGRADATION FP 7 BLEND3 0.78 21-06-15 11:49:09 A/L RATIO DEGRADATION FP 7 BLEND3 0.78 21-06-14 11:49:09 A/L RATIO DEGRADATION FP 7 BLEND3 0.76 21-06-13 11:49:09 A/L RATIO DEGRADATION FP 7 BLEND3 0.77 21-06-12 11:49:09 A/L RATIO DEGRADATION FP 7 BLEND3 0.80 21-06-11 11:49:09 A/L RATIO DEGRADATION FP 7 BLEND3 0.81 21-06-07 11:49:09 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 8.89 FAILURE ALARMS DATE TIME DESCRIPTION READING VALUE 21-04-11 11:49:09 A/L RATIO GROSS BLOCKAGE FP 6 BLEND3 BLKD 20-06-06 11:50:24 A/L RATIO GROSS BLOCKAGE FP 2 BLEND3 BLKD 20-04-08 11:50:32 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 15.53 20-03-29 11:51:04 A/L RATIO GROSS BLOCKAGE FP 6 BLEND3 BLKD 19-01-27 10:02:10 A/L RATIO GROSS BLOCKAGE FP 4 BLEND3 BLKD 19-01-27 10:02:09 A/L RATIO GROSS BLOCKAGE FP 3 BLEND3 BLKD 19-01-07 10:01:27 A/L RATIO GROSS BLOCKAGE FP 2 BLEND3 BLKD 18-11-27 10:01:09 A/L RATIO DEGRADATION FP 5 BLEND3 0.80 18-07-22 10:02:18 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 2.70 17-04-23 10:02:39 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 18.01 SHUTDOWN & MISCELLANEOUS EVENTS DATE TIME DESCRIPTION ACTION/NAME 21-09-14 11:49:09 READINESS ISD:PP EVR:PP ISD & EVR READY 21-09-13 14:16:05 READINESS ISD:PP EVR:NN EVR READINESS PENDING 21-09-13 14:16:05 ISD STARTUP 21-09-13 14:15:54 ISD SHUTDOWN 21-07-28 11:49:11 READINESS ISD:PP EVR:PP ISD & EVR READY 21-07-27 16:45:01 READINESS ISD:PP EVR:NN EVR READINESS PENDING 21-07-27 16:45:01 ISD STARTUP 21-07-27 16:44:52 ISD SHUTDOWN 21-07-27 11:51:16 COLLECTION TEST HH04 GRADE TEST MANUALLY CLEARED 21-05-04 11:58:36 COLLECTION TEST HH01 GRADE TEST MANUALLY CLEARED ALARM HISTORY AFTER Responses Received: I10200 SEP 28, 2021 11:24 AM FASTRIP 562 MING-CHESTER BAKERSFIELD CA 661-397-8606 SYSTEM CONFIGURATION SLOT BOARD TYPE POWER ON RESET CURRENT 1 7SMARTSENSOR BD 508079 507999 2 4 PROBE / G.T. 161504 161460 3 INTERSTITIAL BD 202172 202288 4 INTERSTITIAL BD 202533 202552 5 UNUSED 4812041 4761729 6 UNUSED 4809760 4758341 7 UNUSED 4811310 4758363 8 UNUSED 4810181 4758055 9 STP SENSE BOARD 33224 33194 10 RELAY BOARD 14888 14859 11 RELAY BOARD 14955 14992 12 UNUSED 4813085 4763390 13 UNUSED 4809830 4755689 14 UNUSED 4811668 4756217 15 UNUSED 4807351 4758571 16 UNUSED 4811447 4757405 COMM 1 RS232 SERIAL BD 14932 14925 COMM 2 RS232 SERIAL BD 14977 14947 COMM 3 ELEC DISP INT. 101186 101277 COMM 4 UNUSED 4810118 4758373 COMM 5 UNUSED 4811956 4759759 COMM 6 UNUSED 4806399 4759253 I90200 SEP 28, 2021 11:24 AM SOFTWARE REVISION LEVEL VERSION 329.01 SOFTWARE# 346329-100-B CREATED - 09.01.29.15.44 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD I11100 SEP 28, 2021 11:24 AM FASTRIP 562 MING-CHESTER BAKERSFIELD CA 661-397-8606 PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME L 6 ANNULAR PNL ANN SENSOR OUT ALARM CLEAR 9-28-21 10:15AM L 4 ANNULAR DIESEL ANN SENSOR OUT ALARM CLEAR 9-28-21 10:15AM L 5 STP SUMP PNL STP SENSOR OUT ALARM CLEAR 9-28-21 10:15AM L 3 STP SUMP DIESEL STP SENSOR OUT ALARM CLEAR 9-28-21 10:15AM L 2 ANNULAR UNL1 ANN SENSOR OUT ALARM CLEAR 9-28-21 10:15AM L12 DISP PAN DISP 7-8 SENSOR OUT ALARM CLEAR 9-28-21 10:15AM L 8 ANNULAR UNL2 ANN SENSOR OUT ALARM CLEAR 9-28-21 10:15AM L 1 STP SUMP UNL 1 STP SENSOR OUT ALARM CLEAR 9-28-21 10:15AM L 7 STP SUMP UNL2 SIPON STP SENSOR OUT ALARM CLEAR 9-28-21 10:15AM L14 PIPE TRAN SO. SENSOR OUT ALARM CLEAR 9-28-21 10:15AM L11 DISP PAN DISP 5-6 SENSOR OUT ALARM CLEAR 9-28-21 10:15AM L13 PIPE TRAN NO. SENSOR OUT ALARM CLEAR 9-28-21 10:15AM L10 DISP PAN DISP 3-4 SENSOR OUT ALARM CLEAR 9-28-21 10:15AM L 9 DISP PAN DISP 1-2 SENSOR OUT ALARM CLEAR 9-28-21 10:15AM L 2 ANNULAR UNL1 ANN SENSOR OUT ALARM ALARM 9-28-21 10:14AM L 8 ANNULAR UNL2 ANN SENSOR OUT ALARM ALARM 9-28-21 10:14AM L 1 STP SUMP UNL 1 STP SENSOR OUT ALARM ALARM 9-28-21 10:14AM L 7 STP SUMP UNL2 SIPON STP SENSOR OUT ALARM ALARM 9-28-21 10:14AM L14 PIPE TRAN SO. SENSOR OUT ALARM ALARM 9-28-21 10:14AM L 6 ANNULAR PNL ANN SENSOR OUT ALARM ALARM 9-28-21 10:14AM L13 PIPE TRAN NO. SENSOR OUT ALARM ALARM 9-28-21 10:14AM L 5 STP SUMP PNL STP SENSOR OUT ALARM ALARM 9-28-21 10:14AM L12 DISP PAN DISP 7-8 SENSOR OUT ALARM ALARM 9-28-21 10:14AM L 4 ANNULAR DIESEL ANN SENSOR OUT ALARM ALARM 9-28-21 10:14AM L11 DISP PAN DISP 5-6 SENSOR OUT ALARM ALARM 9-28-21 10:14AM L 3 STP SUMP DIESEL STP SENSOR OUT ALARM ALARM 9-28-21 10:14AM L10 DISP PAN DISP 3-4 SENSOR OUT ALARM ALARM 9-28-21 10:14AM L 9 DISP PAN DISP 1-2 SENSOR OUT ALARM ALARM 9-28-21 10:14AM L14 PIPE TRAN SO. FUEL ALARM CLEAR 9-28-21 10:05AM L14 PIPE TRAN SO. FUEL ALARM ALARM 9-28-21 10:05AM L11 DISP PAN DISP 5-6 FUEL ALARM CLEAR 9-28-21 10:05AM L11 DISP PAN DISP 5-6 FUEL ALARM ALARM 9-28-21 10:05AM L 9 DISP PAN DISP 1-2 FUEL ALARM CLEAR 9-28-21 10:03AM L 9 DISP PAN DISP 1-2 FUEL ALARM ALARM 9-28-21 10:03AM L13 PIPE TRAN NO. FUEL ALARM CLEAR 9-28-21 10:03AM L13 PIPE TRAN NO. FUEL ALARM ALARM 9-28-21 10:03AM L10 DISP PAN DISP 3-4 FUEL ALARM CLEAR 9-28-21 10:02AM L10 DISP PAN DISP 3-4 FUEL ALARM ALARM 9-28-21 10:02AM L 7 STP SUMP UNL2 SIPON STP FUEL ALARM CLEAR 9-28-21 9:57AM L 7 STP SUMP UNL2 SIPON STP FUEL ALARM ALARM 9-28-21 9:57AM L 1 STP SUMP UNL 1 STP FUEL ALARM CLEAR 9-28-21 9:56AM L 1 STP SUMP UNL 1 STP FUEL ALARM ALARM 9-28-21 9:56AM L12 DISP PAN DISP 7-8 FUEL ALARM CLEAR 9-28-21 9:56AM L12 DISP PAN DISP 7-8 FUEL ALARM ALARM 9-28-21 9:56AM L 9 DISP PAN DISP 1-2 FUEL ALARM CLEAR 9-28-21 9:55AM L 9 DISP PAN DISP 1-2 FUEL ALARM ALARM 9-28-21 9:55AM L12 DISP PAN DISP 7-8 FUEL ALARM CLEAR 9-28-21 9:54AM L 1 STP SUMP UNL 1 STP FUEL ALARM CLEAR 9-28-21 9:54AM L 1 STP SUMP UNL 1 STP FUEL ALARM ALARM 9-28-21 9:54AM L12 DISP PAN DISP 7-8 FUEL ALARM ALARM 9-28-21 9:47AM I11200 SEP 28, 2021 11:24 AM FASTRIP 562 MING-CHESTER BAKERSFIELD CA 661-397-8606 NON-PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME SYSTEM PRINTER ERROR CLEAR 8-30-21 4:21PM SYSTEM PAPER OUT CLEAR 8-30-21 4:21PM SYSTEM PRINTER ERROR ALARM 8-30-21 4:18PM SYSTEM PAPER OUT ALARM 8-30-21 4:18PM T 2 TANK DIESEL DELIVERY NEEDED CLEAR 8-15-21 1:57AM T 2 TANK DIESEL DELIVERY NEEDED ALARM 8-14-21 11:50AM SYSTEM PRINTER ERROR CLEAR 8-03-21 2:43PM SYSTEM PAPER OUT CLEAR 8-03-21 2:43PM SYSTEM PRINTER ERROR ALARM 8-03-21 2:41PM SYSTEM PAPER OUT ALARM 8-03-21 2:41PM T 2 TANK DIESEL DELIVERY NEEDED CLEAR 8-01-21 5:06AM T 2 TANK DIESEL DELIVERY NEEDED ALARM 7-31-21 8:24PM h 4 OTHER FP4: BLEND3 DEGRD COLLECT WARN CLEAR 7-27-21 11:51AM h 4 OTHER FP4: BLEND3 DEGRD COLLECT WARN ALARM 7-27-21 11:49AM SYSTEM PRINTER ERROR CLEAR 7-18-21 12:32PM SYSTEM PAPER OUT CLEAR 7-18-21 12:32PM SYSTEM PRINTER ERROR ALARM 7-18-21 12:30PM SYSTEM PAPER OUT ALARM 7-18-21 12:30PM OTHER ISD VAPOR LEAK WARN CLEAR 7-13-21 11:48AM OTHER ISD VAPOR LEAK WARN ALARM 7-12-21 11:49AM SYSTEM PRINTER ERROR CLEAR 6-27-21 3:11AM SYSTEM PAPER OUT CLEAR 6-27-21 3:11AM SYSTEM PRINTER ERROR ALARM 6-27-21 3:08AM SYSTEM PAPER OUT ALARM 6-27-21 3:08AM h 7 OTHER FP7: BLEND3 DEGRD COLLECT WARN CLEAR 6-18-21 11:48AM h 7 OTHER FP7: BLEND3 DEGRD COLLECT WARN ALARM 6-11-21 11:49AM OTHER ISD VAPOR LEAK WARN CLEAR 6-08-21 11:48AM OTHER ISD VAPOR LEAK WARN ALARM 6-07-21 11:49AM SYSTEM PRINTER ERROR CLEAR 6-06-21 1:25PM SYSTEM PAPER OUT CLEAR 6-06-21 1:25PM SYSTEM PRINTER ERROR ALARM 6-06-21 1:25PM SYSTEM PAPER OUT ALARM 6-06-21 1:25PM SYSTEM PRINTER ERROR CLEAR 6-06-21 12:23PM SYSTEM PAPER OUT CLEAR 6-06-21 12:23PM SYSTEM PRINTER ERROR ALARM 6-06-21 12:21PM SYSTEM PAPER OUT ALARM 6-06-21 12:21PM h 7 OTHER FP7: BLEND3 DEGRD COLLECT WARN CLEAR 5-26-21 11:48AM h 7 OTHER FP7: BLEND3 DEGRD COLLECT WARN ALARM 5-25-21 11:49AM h 2 OTHER FP2: BLEND3 DEGRD COLLECT WARN CLEAR 5-19-21 11:48AM h 2 OTHER FP2: BLEND3 DEGRD COLLECT WARN ALARM 5-18-21 11:49AM h 1 OTHER FP1: BLEND3 DEGRD COLLECT WARN CLEAR 5-04-21 11:58AM h 1 OTHER FP1: BLEND3 DEGRD COLLECT WARN ALARM 5-02-21 11:49AM T 4 TANK UNL 2 SIPHON DELIVERY NEEDED CLEAR 4-19-21 12:58AM T 4 TANK UNL 2 SIPHON DELIVERY NEEDED ALARM 4-18-21 10:24PM h 6 OTHER FP6: BLEND3 GROSS COLLECT WARN CLEAR 4-16-21 5:28PM h 5 OTHER FP5: BLEND3 GROSS COLLECT WARN CLEAR 4-16-21 5:28PM h 6 OTHER FP6: BLEND3 GROSS COLLECT WARN ALARM 4-16-21 11:49AM h 5 OTHER FP5: BLEND3 GROSS COLLECT WARN ALARM 4-16-21 11:49AM h 6 OTHER FP6: BLEND3 GROSS COLLECT WARN CLEAR 4-14-21 10:14AM h 6 OTHER FP6: BLEND3 GROSS COLLECT WARN ALARM 4-13-21 11:49AM I20600 SEP 28, 2021 11:24 AM FASTRIP 562 MING-CHESTER BAKERSFIELD CA 661-397-8606 TANK ALARM HISTORY TANK 1 UNL SETUP DATA WARNING JAN 29, 2009 8:13 AM OVERFILL ALARM SEP 8, 2021 9:25 PM AUG 7, 2021 7:13 AM AUG 4, 2021 3:36 PM SUDDEN LOSS ALARM JUL 25, 2021 3:26 AM JUL 25, 2021 2:38 AM JUL 25, 2021 2:06 AM HIGH PRODUCT ALARM SEP 8, 2020 11:51 AM JUL 9, 2019 5:06 PM MAY 12, 2019 6:37 AM PROBE OUT SEP 8, 2020 11:52 AM SEP 8, 2020 11:50 AM NOV 28, 2018 12:07 PM DELIVERY NEEDED APR 27, 2020 10:41 AM LOW TEMP WARNING SEP 8, 2020 11:53 AM NOV 28, 2018 12:07 PM TANK 2 DIESEL HIGH WATER ALARM SEP 1, 2020 12:00 PM OVERFILL ALARM SEP 8, 2020 11:32 AM SEP 1, 2020 12:19 PM NOV 28, 2018 11:54 AM LOW PRODUCT ALARM SEP 8, 2020 11:33 AM SEP 1, 2020 11:53 AM INVALID FUEL LEVEL SEP 8, 2020 11:33 AM SEP 8, 2020 11:31 AM SEP 2, 2020 9:16 AM PROBE OUT SEP 8, 2020 11:33 AM SEP 8, 2020 11:30 AM SEP 1, 2020 5:21 PM HIGH WATER WARNING SEP 1, 2020 12:00 PM DELIVERY NEEDED AUG 14, 2021 11:50 AM JUL 31, 2021 8:24 PM JAN 14, 2021 8:29 AM LOW TEMP WARNING NOV 28, 2018 11:56 AM TANK 3 PNL HIGH WATER ALARM SEP 1, 2020 5:26 PM OVERFILL ALARM SEP 8, 2020 11:28 AM SEP 1, 2020 12:33 PM NOV 28, 2018 11:58 AM SUDDEN LOSS ALARM SEP 8, 2020 11:26 AM SEP 8, 2020 10:43 AM SEP 1, 2020 11:50 AM HIGH PRODUCT ALARM SEP 8, 2020 11:28 AM SEP 1, 2020 5:27 PM SEP 1, 2020 5:23 PM INVALID FUEL LEVEL SEP 8, 2020 11:29 AM SEP 1, 2020 5:35 PM MAR 5, 2020 12:03 PM PROBE OUT SEP 8, 2020 11:28 AM SEP 8, 2020 11:26 AM SEP 1, 2020 5:38 PM HIGH WATER WARNING SEP 1, 2020 5:26 PM DELIVERY NEEDED SEP 8, 2020 11:29 AM SEP 8, 2020 11:27 AM SEP 8, 2020 10:43 AM MAX PRODUCT ALARM SEP 1, 2020 5:27 PM SEP 1, 2020 5:23 PM LOW TEMP WARNING SEP 1, 2020 5:39 PM NOV 28, 2018 11:59 AM SEP 10, 2018 10:05 AM TANK 4 UNL 2 SIPHON OVERFILL ALARM SEP 8, 2021 9:20 PM NOV 27, 2020 11:57 AM SEP 8, 2020 11:56 AM HIGH PRODUCT ALARM SEP 8, 2020 11:56 AM PROBE OUT SEP 8, 2020 11:57 AM SEP 8, 2020 11:54 AM JAN 22, 2019 11:39 AM DELIVERY NEEDED APR 18, 2021 10:24 PM JAN 17, 2019 2:31 PM LOW TEMP WARNING NOV 28, 2018 12:14 PM I38200 SEP 28, 2021 11:24 AM I30200 SEP 28, 2021 11:24 AM FASTRIP 562 MING-CHESTER BAKERSFIELD CA 661-397-8606 LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 UNL 1 STP SEP 28, 2021 10:14 AM SENSOR OUT ALARM SEP 28, 2021 9:56 AM FUEL ALARM SEP 28, 2021 9:54 AM FUEL ALARM 2 UNL1 ANN SEP 28, 2021 10:14 AM SENSOR OUT ALARM SEP 28, 2021 9:39 AM FUEL ALARM SEP 13, 2021 2:13 PM SENSOR OUT ALARM 3 DIESEL STP SEP 28, 2021 10:14 AM SENSOR OUT ALARM SEP 28, 2021 9:34 AM FUEL ALARM SEP 13, 2021 2:13 PM SENSOR OUT ALARM 4 DIESEL ANN SEP 28, 2021 10:14 AM SENSOR OUT ALARM SEP 28, 2021 9:40 AM FUEL ALARM SEP 13, 2021 2:13 PM FUEL ALARM 5 PNL STP SEP 28, 2021 10:14 AM SENSOR OUT ALARM SEP 28, 2021 9:33 AM FUEL ALARM SEP 13, 2021 2:13 PM SENSOR OUT ALARM 6 PNL ANN SEP 28, 2021 10:14 AM SENSOR OUT ALARM SEP 28, 2021 9:41 AM FUEL ALARM SEP 13, 2021 2:13 PM SENSOR OUT ALARM 7 UNL2 SIPON STP SEP 28, 2021 10:14 AM SENSOR OUT ALARM SEP 28, 2021 9:57 AM FUEL ALARM SEP 28, 2021 9:37 AM FUEL ALARM 8 UNL2 ANN SEP 28, 2021 10:14 AM SENSOR OUT ALARM SEP 28, 2021 9:38 AM FUEL ALARM SEP 13, 2021 2:13 PM SENSOR OUT ALARM 9 DISP 1-2 SEP 28, 2021 10:14 AM SENSOR OUT ALARM SEP 28, 2021 10:03 AM FUEL ALARM SEP 28, 2021 9:55 AM FUEL ALARM 10 DISP 3-4 SEP 28, 2021 10:14 AM SENSOR OUT ALARM SEP 28, 2021 10:02 AM FUEL ALARM SEP 13, 2021 2:13 PM SENSOR OUT ALARM 11 DISP 5-6 SEP 28, 2021 10:14 AM SENSOR OUT ALARM SEP 28, 2021 10:05 AM FUEL ALARM SEP 13, 2021 2:13 PM SENSOR OUT ALARM 12 DISP 7-8 SEP 28, 2021 10:14 AM SENSOR OUT ALARM SEP 28, 2021 9:56 AM FUEL ALARM SEP 28, 2021 9:47 AM FUEL ALARM 13 TRAN NO. SEP 28, 2021 10:14 AM SENSOR OUT ALARM SEP 28, 2021 10:03 AM FUEL ALARM SEP 13, 2021 2:12 PM SENSOR OUT ALARM 14 TRAN SO. SEP 28, 2021 10:14 AM SENSOR OUT ALARM SEP 28, 2021 10:05 AM FUEL ALARM SEP 13, 2021 2:13 PM SENSOR OUT ALARM I31600 SEP 28, 2021 11:24 AM FASTRIP 562 MING-CHESTER BAKERSFIELD CA 661-397-8606 SMART SENSOR ALARM HISTORY REPORT SENSOR LOCATION 1 V.P.SENSOR DISP 3-4 2 F.M.DISP 1-2 3 F.M.DISP 3-4 4 F.M.DISP 5-6 5 F.M.DISP 7-8 FEB 22, 2020 8:22 AM COMMUNICATION ALARM FEB 16, 2020 8:41 AM COMMUNICATION ALARM DEC 22, 2019 3:33 PM COMMUNICATION ALARM I40200 SEP 28, 2021 11:24 AM I40300 SEP 28, 2021 11:24 AM I34200 SEP 28, 2021 11:24 AM I34700 SEP 28, 2021 11:24 AM IV0100 SEP 28, 2021 11:24 AM FASTRIP 562 MING-CHESTER BAKERSFIELD CA 661-397-8606 ISD ALARM STATUS REPORT EVR TYPE: VACUUM ASSIST ISD TYPE: 01.02 VAPOR PROCESSOR TYPE: NONE OVERALL STATUS :PASS EVR VAPOR COLLECTION :PASS EVR VAPOR CONTAINMENT :PASS ISD MONITOR UP-TIME :100% STAGE I TRANSFERS: 0 of 0 NOTEST EVR/ISD PASS TIME :100% WARNING ALARMS DATE TIME DESCRIPTION READING VALUE 21-07-27 11:49:09 A/L RATIO DEGRADATION FP 4 BLEND3 0.00 21-07-12 11:49:09 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 9.19 21-06-17 11:49:09 A/L RATIO DEGRADATION FP 7 BLEND3 0.79 21-06-16 11:49:09 A/L RATIO DEGRADATION FP 7 BLEND3 0.78 21-06-15 11:49:09 A/L RATIO DEGRADATION FP 7 BLEND3 0.78 21-06-14 11:49:09 A/L RATIO DEGRADATION FP 7 BLEND3 0.76 21-06-13 11:49:09 A/L RATIO DEGRADATION FP 7 BLEND3 0.77 21-06-12 11:49:09 A/L RATIO DEGRADATION FP 7 BLEND3 0.80 21-06-11 11:49:09 A/L RATIO DEGRADATION FP 7 BLEND3 0.81 21-06-07 11:49:09 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 8.89 FAILURE ALARMS DATE TIME DESCRIPTION READING VALUE 21-04-11 11:49:09 A/L RATIO GROSS BLOCKAGE FP 6 BLEND3 BLKD 20-06-06 11:50:24 A/L RATIO GROSS BLOCKAGE FP 2 BLEND3 BLKD 20-04-08 11:50:32 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 15.53 20-03-29 11:51:04 A/L RATIO GROSS BLOCKAGE FP 6 BLEND3 BLKD 19-01-27 10:02:10 A/L RATIO GROSS BLOCKAGE FP 4 BLEND3 BLKD 19-01-27 10:02:09 A/L RATIO GROSS BLOCKAGE FP 3 BLEND3 BLKD 19-01-07 10:01:27 A/L RATIO GROSS BLOCKAGE FP 2 BLEND3 BLKD 18-11-27 10:01:09 A/L RATIO DEGRADATION FP 5 BLEND3 0.80 18-07-22 10:02:18 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 2.70 17-04-23 10:02:39 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 18.01 SHUTDOWN & MISCELLANEOUS EVENTS DATE TIME DESCRIPTION ACTION/NAME 21-09-28 10:19:53 READINESS ISD:PP EVR:NN EVR READINESS PENDING 21-09-28 10:19:53 ISD STARTUP 21-09-28 10:19:40 ISD SHUTDOWN 21-09-14 11:49:09 READINESS ISD:PP EVR:PP ISD & EVR READY 21-09-13 14:16:05 READINESS ISD:PP EVR:NN EVR READINESS PENDING 21-09-13 14:16:05 ISD STARTUP 21-09-13 14:15:54 ISD SHUTDOWN 21-07-28 11:49:11 READINESS ISD:PP EVR:PP ISD & EVR READY 21-07-27 16:45:01 READINESS ISD:PP EVR:NN EVR READINESS PENDING 21-07-27 16:45:01 ISD STARTUP