HomeMy WebLinkAboutOPSR-8001 White Ln 9-13-21 (East)Appendix IX Underground Storage Tank Overfill Prevention Equipment Inspection Report Form CERS = California Environmental Reporting System, ID = Identification, ICC = International Code Council, OPE = Overfill Prevention Equipment Page 1 of 2 TYPE OF ACTION ܆܆ Installation ܆ Repair ܆ 36 Month 1. FACILITY INFORMATION CERS ID Inspection Date Facility Name Facility Address City ZIP Code 2. SERVICE TECHNICIAN INFORMATION Company Performing the Inspection Phone Mailing Address Service Technician Performing Inspection Contractor/Tank Tester License Number ICC Number Expiration Date 3. TRAINING AND CERTIFICATIONS Manufacturer and Test Equipment Training Certifications Expiration Date 4. INSPECTION PROCEDURES INFORMATION Inspection Procedures Used Components Inspected 5. CERTIFICATION BY SERVICE TECHNICIAN CONDUCTING INSPECTION I hereby certify that the OPE was inspected in accordance with California Code of Regulations, title 23, division 3, chapter 16, section 2637.2; that required supporting documentation is attached; and all information contained herein is accurate. I understand that test procedures shall be made available upon request by the governing authority. Service Technician Signature Date 10137943 09-13-2021 Jaco #3367 Fastrip #640 (East) 8001 White Lane Bakersfield 93309 Confidence UST Services, Inc.(800) 339-9930 2209 Zeus Court, Bakersfield, CA 93308 Ronald Clark 804904 9482314 06-15-2022 Veeder-Root C27795 08-26-2022 Precision measurement device Drop tubes 09-13-2021 Total # of Pages 10 Underground Storage Tank Overfill Prevention Equipment Inspection Report Additional copies of this page may be attached. Attach tank chart(s), measurements, calculations, and In-Tank Setup report(s) Page 2 of 2 6. OVERFILL PREVENTION EQUIPMENT DETAILS Tank ID (one OPE per column) Are both vent and tank riser piping secondarily contained? ܆܆ Yes ܆܆ No ܆܆ Yes ܆܆ No ܆܆ Yes ܆܆ No ܆܆ Yes ܆܆ No OPE Model What is the OPE response when activated? (Check all that apply.) ܆܆ Shut off Flow ܆܆Restricts Flow ܆܆ Audible Alarm ܆܆ Visual Alarm ܆܆ Shut off Flow ܆܆Restricts Flow ܆܆ Audible Alarm ܆܆ Visual Alarm ܆܆ Shut off Flow ܆܆Restricts Flow ܆܆ Audible Alarm ܆܆ Visual Alarm ܆܆ Shut off Flow ܆܆Restricts Flow ܆܆ Audible Alarm ܆܆ Visual Alarm Are flow restrictors installed on vent piping that may interfere with the OPE operation? ܆܆ Yes* ܆܆ No ܆܆ Yes* ܆܆ No ܆܆ Yes* ܆܆ No ܆܆ Yes* ܆܆ No At what level in the tank is the OPE set to activate? (Inches from bottom of tank) What is the percent capacity of the tank at which the OPE activates? Is the OPE in proper operating condition to respond when the stored substance reaches the designated regulatory level? ܆܆ Yes ܆܆ No ܆܆ Yes ܆܆ No ܆܆ Yes ܆܆ No ܆܆ Yes ܆܆ No 7. SUMMARY OF TESTING RESULTS OPE Inspection Results ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail 1 8. COMMENTS Describe all results marked “Fail” and each proposed remedy. * Mark here if: ܆܆ Flow restrictors interfere with overfill prevention and equipment repairs required. T1 unleaded OPW 71SO OPW 71SO OPW 71SO OPW 71SO 78.75”97.50”97”96.5” 92%92%92%92% T2 unleaded 2 T3 premium T4 diesel 21 Appendix B 71SO Overfill Valve in Tank Shut off Level Worksheet Important: This is meant to be supplemental worksheet and not a substitute to following the installation manual instructions. All length measurements are in inches. Please contact the Authority Having Jurisdic- tion (AHJ) and review local, state, and national codes to determine the regulatory requirements governing shut-off capacity in your region, as well as take into account other considerations such as extreme tank tilt. Take the following measurements with the valve in- stalled in the tank: Distance from the 71SO inlet tube flange to the cast lug in the 71SO body (see figures), upper tube length. Note: the Upper Tube Length must be at least 16” to in- clude the protective bend in the tube. (D)= ______________________ Distance from the 71SO inlet tube flange to the top and bottom of lower tube, valve length. (W)= _____________ (U)= _____________ Distance from the 71SO inlet tube flange to the bottom of the tank. Note: If a tank bottom protector is present it may be necessary to add this thickness to dimension (OPW 6111 & 61TP models add 0.6”) (B)= _____________ From the tank calibration chart provided by tank manu- facturer find the dipstick number (Y) which corresponds to the 100% volume. (Y)= _____________ 1. To determine shut-off percentage: Subtract upper tube length (D) from distance to tank bottom (B) (X) = (B) – (D) - 2” =________________________ Using the tank calibration chart provided by the tank manufacturer determine the tank capacity at the cal- culated (X) dimension and the 100% volume (Y) tank capacity. (X) tank capacity in gallons = _______________ (Y) tank capacity in gallons = _______________ SO% = (X) capacity / (Y) capacity x100 = __________ Note: The overfill valve must be installed per AHJ require- ments and all applicable local, state, and national codes. If the overfill valve is set above the allowable shut-off percent- age the overfill valve must be removed and replaced. For reference 40 CFR part 280 Subpart B Section 280.20 overfill valves should be set to a maximum of 95%. (B) To Tank (D) Upper Tube (W) Valve Length, bottom of cut (Y) Tank Chart 100% Volume Dipstick (U) Valve Length, top of cut 3URGXFW87(1) 56.25” 132” 132” 137” 91.63” 78.75” 10645 11595 92% 21 Appendix B 71SO Overfill Valve in Tank Shut off Level Worksheet Important: This is meant to be supplemental worksheet and not a substitute to following the installation manual instructions. All length measurements are in inches. Please contact the Authority Having Jurisdic- tion (AHJ) and review local, state, and national codes to determine the regulatory requirements governing shut-off capacity in your region, as well as take into account other considerations such as extreme tank tilt. Take the following measurements with the valve in- stalled in the tank: Distance from the 71SO inlet tube flange to the cast lug in the 71SO body (see figures), upper tube length. Note: the Upper Tube Length must be at least 16” to in- clude the protective bend in the tube. (D)= ______________________ Distance from the 71SO inlet tube flange to the top and bottom of lower tube, valve length. (W)= _____________ (U)= _____________ Distance from the 71SO inlet tube flange to the bottom of the tank. Note: If a tank bottom protector is present it may be necessary to add this thickness to dimension (OPW 6111 & 61TP models add 0.6”) (B)= _____________ From the tank calibration chart provided by tank manu- facturer find the dipstick number (Y) which corresponds to the 100% volume. (Y)= _____________ 1. To determine shut-off percentage: Subtract upper tube length (D) from distance to tank bottom (B) (X) = (B) – (D) - 2” =________________________ Using the tank calibration chart provided by the tank manufacturer determine the tank capacity at the cal- culated (X) dimension and the 100% volume (Y) tank capacity. (X) tank capacity in gallons = _______________ (Y) tank capacity in gallons = _______________ SO% = (X) capacity / (Y) capacity x100 = __________ Note: The overfill valve must be installed per AHJ require- ments and all applicable local, state, and national codes. If the overfill valve is set above the allowable shut-off percent- age the overfill valve must be removed and replaced. For reference 40 CFR part 280 Subpart B Section 280.20 overfill valves should be set to a maximum of 95%. (B) To Tank (D) Upper Tube (W) Valve Length, bottom of cut (Y) Tank Chart 100% Volume Dipstick (U) Valve Length, top of cut 3URGXFW87(2) 56.50” 152.75” 151.50’ 155” 112” 97.50” 11114 12027 92% 21 Appendix B 71SO Overfill Valve in Tank Shut off Level Worksheet Important: This is meant to be supplemental worksheet and not a substitute to following the installation manual instructions. All length measurements are in inches. Please contact the Authority Having Jurisdic- tion (AHJ) and review local, state, and national codes to determine the regulatory requirements governing shut-off capacity in your region, as well as take into account other considerations such as extreme tank tilt. Take the following measurements with the valve in- stalled in the tank: Distance from the 71SO inlet tube flange to the cast lug in the 71SO body (see figures), upper tube length. Note: the Upper Tube Length must be at least 16” to in- clude the protective bend in the tube. (D)= ______________________ Distance from the 71SO inlet tube flange to the top and bottom of lower tube, valve length. (W)= _____________ (U)= _____________ Distance from the 71SO inlet tube flange to the bottom of the tank. Note: If a tank bottom protector is present it may be necessary to add this thickness to dimension (OPW 6111 & 61TP models add 0.6”) (B)= _____________ From the tank calibration chart provided by tank manu- facturer find the dipstick number (Y) which corresponds to the 100% volume. (Y)= _____________ 1. To determine shut-off percentage: Subtract upper tube length (D) from distance to tank bottom (B) (X) = (B) – (D) - 2” =________________________ Using the tank calibration chart provided by the tank manufacturer determine the tank capacity at the cal- culated (X) dimension and the 100% volume (Y) tank capacity. (X) tank capacity in gallons = _______________ (Y) tank capacity in gallons = _______________ SO% = (X) capacity / (Y) capacity x100 = __________ Note: The overfill valve must be installed per AHJ require- ments and all applicable local, state, and national codes. If the overfill valve is set above the allowable shut-off percent- age the overfill valve must be removed and replaced. For reference 40 CFR part 280 Subpart B Section 280.20 overfill valves should be set to a maximum of 95%. (B) To Tank (D) Upper Tube (W) Valve Length, bottom of cut (Y) Tank Chart 100% Volume Dipstick (U) Valve Length, top of cut 3URGXFW91 57.50 152.50” 151.50” 156.50 112” 97” 11068 12027 92% 21 Appendix B 71SO Overfill Valve in Tank Shut off Level Worksheet Important: This is meant to be supplemental worksheet and not a substitute to following the installation manual instructions. All length measurements are in inches. Please contact the Authority Having Jurisdic- tion (AHJ) and review local, state, and national codes to determine the regulatory requirements governing shut-off capacity in your region, as well as take into account other considerations such as extreme tank tilt. Take the following measurements with the valve in- stalled in the tank: Distance from the 71SO inlet tube flange to the cast lug in the 71SO body (see figures), upper tube length. Note: the Upper Tube Length must be at least 16” to in- clude the protective bend in the tube. (D)= ______________________ Distance from the 71SO inlet tube flange to the top and bottom of lower tube, valve length. (W)= _____________ (U)= _____________ Distance from the 71SO inlet tube flange to the bottom of the tank. Note: If a tank bottom protector is present it may be necessary to add this thickness to dimension (OPW 6111 & 61TP models add 0.6”) (B)= _____________ From the tank calibration chart provided by tank manu- facturer find the dipstick number (Y) which corresponds to the 100% volume. (Y)= _____________ 1. To determine shut-off percentage: Subtract upper tube length (D) from distance to tank bottom (B) (X) = (B) – (D) - 2” =________________________ Using the tank calibration chart provided by the tank manufacturer determine the tank capacity at the cal- culated (X) dimension and the 100% volume (Y) tank capacity. (X) tank capacity in gallons = _______________ (Y) tank capacity in gallons = _______________ SO% = (X) capacity / (Y) capacity x100 = __________ Note: The overfill valve must be installed per AHJ require- ments and all applicable local, state, and national codes. If the overfill valve is set above the allowable shut-off percent- age the overfill valve must be removed and replaced. For reference 40 CFR part 280 Subpart B Section 280.20 overfill valves should be set to a maximum of 95%. (B) To Tank (D) Upper Tube (W) Valve Length, bottom of cut (Y) Tank Chart 100% Volume Dipstick (U) Valve Length, top of cut 3URGXFWDiesel 59.5” 153” 153” 158 112 96.5” 11021 12027 92% 8' 12000 DWT6 Double Wall Tank 11595 Gals DIPSTICK GALLONS DIPSTICK GALLONS DIPSTICK GALLONS DIPSTICK GALLONS DIPSTICK GALLONS 1/8 6 6 1/8 336 12 1/8 896 18 1/8 1601 24 1/8 2412 1/4 9 6 1/4 346 12 1/4 909 18 1/4 1617 24 1/4 2430 3/8 12 6 3/8 356 12 3/8 923 18 3/8 1633 24 3/8 2448 1/2 15 6 1/2 366 12 1/2 936 18 1/2 1649 24 1/2 2465 5/8 19 6 5/8 376 12 5/8 950 18 5/8 1665 24 5/8 2483 3/4 23 6 3/4 386 12 3/4 964 18 3/4 1681 24 3/4 2501 7/8 27 6 7/8 397 12 7/8 977 18 7/8 1697 24 7/8 2519 1 31 7 407 13 991 19 1714 25 2537 1 1/8 36 7 1/8 417 13 1/8 1005 19 1/8 1730 25 1/8 2555 1 1/4 40 7 1/4 428 13 1/4 1019 19 1/4 1746 25 1/4 2573 1 3/8 45 7 3/8 438 13 3/8 1033 19 3/8 1762 25 3/8 2591 1 1/2 50 7 1/2 449 13 1/2 1047 19 1/2 1779 25 1/2 2610 1 5/8 56 7 5/8 460 13 5/8 1061 19 5/8 1795 25 5/8 2628 1 3/4 61 7 3/4 471 13 3/4 1075 19 3/4 1812 25 3/4 2646 1 7/8 67 7 7/8 481 13 7/8 1089 19 7/8 1828 25 7/8 2664 2 73 8 492 14 1103 20 1845 26 2682 2 1/8 79 8 1/8 504 14 1/8 1117 20 1/8 1861 26 1/8 2701 2 1/4 85 8 1/4 515 14 1/4 1132 20 1/4 1878 26 1/4 2719 2 3/8 91 8 3/8 526 14 3/8 1146 20 3/8 1894 26 3/8 2737 2 1/2 97 8 1/2 537 14 1/2 1160 20 1/2 1911 26 1/2 2756 2 5/8 104 8 5/8 549 14 5/8 1175 20 5/8 1928 26 5/8 2774 2 3/4 111 8 3/4 560 14 3/4 1189 20 3/4 1945 26 3/4 2792 2 7/8 118 8 7/8 572 14 7/8 1204 20 7/8 1961 26 7/8 2811 3 125 9 583 15 1219 21 1978 27 2829 3 1/8 132 9 1/8 595 15 1/8 1233 21 1/8 1995 27 1/8 2848 3 1/4 139 9 1/4 607 15 1/4 1248 21 1/4 2012 27 1/4 2866 3 3/8 146 9 3/8 618 15 3/8 1263 21 3/8 2029 27 3/8 2885 3 1/2 154 9 1/2 630 15 1/2 1278 21 1/2 2046 27 1/2 29033 1/2 154 9 1/2 630 15 1/2 1278 21 1/2 2046 27 1/2 2903 3 5/8 161 9 5/8 642 15 5/8 1293 21 5/8 2063 27 5/8 2922 3 3/4 169 9 3/4 654 15 3/4 1308 21 3/4 2080 27 3/4 2941 3 7/8 177 9 7/8 666 15 7/8 1323 21 7/8 2097 27 7/8 2959 4 185 10 679 16 1338 22 2115 28 2978 4 1/8 193 10 1/8 691 16 1/8 1353 22 1/8 2132 28 1/8 2997 4 1/4 201 10 1/4 703 16 1/4 1368 22 1/4 2149 28 1/4 3016 4 3/8 209 10 3/8 716 16 3/8 1383 22 3/8 2166 28 3/8 3034 4 1/2 218 10 1/2 728 16 1/2 1398 22 1/2 2184 28 1/2 3053 4 5/8 226 10 5/8 741 16 5/8 1414 22 5/8 2201 28 5/8 3072 4 3/4 235 10 3/4 753 16 3/4 1429 22 3/4 2218 28 3/4 3091 4 7/8 244 10 7/8 766 16 7/8 1444 22 7/8 2236 28 7/8 3110 5 253 11 779 17 1460 23 2253 29 3129 5 1/8 261 11 1/8 791 17 1/8 1475 23 1/8 2271 29 1/8 3147 5 1/4 270 11 1/4 804 17 1/4 1491 23 1/4 2288 29 1/4 3166 5 3/8 280 11 3/8 817 17 3/8 1507 23 3/8 2306 29 3/8 3185 5 1/2 289 11 1/2 830 17 1/2 1522 23 1/2 2323 29 1/2 3204 5 5/8 298 11 5/8 843 17 5/8 1538 23 5/8 2341 29 5/8 3223 5 3/4 308 11 3/4 856 17 3/4 1554 23 3/4 2359 29 3/4 3242 5 7/8 317 11 7/8 870 17 7/8 1569 23 7/8 2376 29 7/8 3262 6 327 12 883 18 1585 24 2394 30 3281 1 8' 12000 DWT6 Double Wall Tank 11595 Gals DIPSTICK GALLONS DIPSTICK GALLONS DIPSTICK GALLONS DIPSTICK GALLONS DIPSTICK GALLONS 30 1/8 3300 36 1/8 4241 42 1/8 5213 48 1/8 6198 54 1/8 7174 30 1/4 3319 36 1/4 4261 42 1/4 5234 48 1/4 6218 54 1/4 7194 30 3/8 3338 36 3/8 4281 42 3/8 5254 48 3/8 6239 54 3/8 7214 30 1/2 3357 36 1/2 4301 42 1/2 5275 48 1/2 6259 54 1/2 7234 30 5/8 3376 36 5/8 4321 42 5/8 5295 48 5/8 6280 54 5/8 7254 30 3/4 3396 36 3/4 4341 42 3/4 5316 48 3/4 6300 54 3/4 7274 30 7/8 3415 36 7/8 4361 42 7/8 5336 48 7/8 6321 54 7/8 7294 31 3434 37 4381 43 5357 49 6341 55 7314 31 1/8 3453 37 1/8 4401 43 1/8 5377 49 1/8 6361 55 1/8 7335 31 1/4 3473 37 1/4 4421 43 1/4 5398 49 1/4 6382 55 1/4 7355 31 3/8 3492 37 3/8 4441 43 3/8 5418 49 3/8 6402 55 3/8 7375 31 1/2 3511 37 1/2 4462 43 1/2 5439 49 1/2 6423 55 1/2 7395 31 5/8 3531 37 5/8 4482 43 5/8 5459 49 5/8 6443 55 5/8 7414 31 3/4 3550 37 3/4 4502 43 3/4 5480 49 3/4 6464 55 3/4 7434 31 7/8 3570 37 7/8 4522 43 7/8 5500 49 7/8 6484 55 7/8 7454 32 3589 38 4542 44 5521 50 6505 56 7474 32 1/8 3609 38 1/8 4562 44 1/8 5541 50 1/8 6525 56 1/8 7494 32 1/4 3628 38 1/4 4583 44 1/4 5562 50 1/4 6545 56 1/4 7514 32 3/8 3648 38 3/8 4603 44 3/8 5582 50 3/8 6566 56 3/8 7534 32 1/2 3667 38 1/2 4623 44 1/2 5603 50 1/2 6586 56 1/2 7554 32 5/8 3687 38 5/8 4643 44 5/8 5623 50 5/8 6607 56 5/8 7574 32 3/4 3706 38 3/4 4663 44 3/4 5644 50 3/4 6627 56 3/4 7594 32 7/8 3726 38 7/8 4684 44 7/8 5664 50 7/8 6647 56 7/8 7613 33 3745 39 4704 45 5685 51 6668 57 7633 33 1/8 3765 39 1/8 4724 45 1/8 5705 51 1/8 6688 57 1/8 7653 33 1/4 3785 39 1/4 4745 45 1/4 5726 51 1/4 6708 57 1/4 7673 33 3/8 3804 39 3/8 4765 45 3/8 5746 51 3/8 6729 57 3/8 7692 33 1/2 3824 39 1/2 4785 45 1/2 5767 51 1/2 6749 57 1/2 771233 1/2 3824 39 1/2 4785 45 1/2 5767 51 1/2 6749 57 1/2 7712 33 5/8 3844 39 5/8 4805 45 5/8 5787 51 5/8 6769 57 5/8 7732 33 3/4 3863 39 3/4 4826 45 3/4 5808 51 3/4 6790 57 3/4 7752 33 7/8 3883 39 7/8 4846 45 7/8 5828 51 7/8 6810 57 7/8 7771 34 3903 40 4866 46 5849 52 6830 58 7791 34 1/8 3922 40 1/8 4887 46 1/8 5869 52 1/8 6851 58 1/8 7811 34 1/4 3942 40 1/4 4907 46 1/4 5890 52 1/4 6871 58 1/4 7830 34 3/8 3962 40 3/8 4928 46 3/8 5910 52 3/8 6891 58 3/8 7850 34 1/2 3982 40 1/2 4948 46 1/2 5931 52 1/2 6911 58 1/2 7869 34 5/8 4002 40 5/8 4968 46 5/8 5952 52 5/8 6932 58 5/8 7889 34 3/4 4021 40 3/4 4989 46 3/4 5972 52 3/4 6952 58 3/4 7909 34 7/8 4041 40 7/8 5009 46 7/8 5993 52 7/8 6972 58 7/8 7928 35 4061 41 5029 47 6013 53 6992 59 7948 35 1/8 4081 41 1/8 5050 47 1/8 6034 53 1/8 7013 59 1/8 7967 35 1/4 4101 41 1/4 5070 47 1/4 6054 53 1/4 7033 59 1/4 7987 35 3/8 4121 41 3/8 5091 47 3/8 6075 53 3/8 7053 59 3/8 8006 35 1/2 4141 41 1/2 5111 47 1/2 6095 53 1/2 7073 59 1/2 8026 35 5/8 4161 41 5/8 5132 47 5/8 6116 53 5/8 7093 59 5/8 8045 35 3/4 4181 41 3/4 5152 47 3/4 6136 53 3/4 7114 59 3/4 8064 35 7/8 4201 41 7/8 5172 47 7/8 6157 53 7/8 7134 59 7/8 8084 36 4221 42 5193 48 6177 54 7154 60 8103 2 8' 12000 DWT6 Double Wall Tank 11595 Gals DIPSTICK GALLONS DIPSTICK GALLONS DIPSTICK GALLONS DIPSTICK GALLONS DIPSTICK GALLONS 60 1/8 8122 66 1/8 9022 72 1/8 9849 78 1/8 10577 84 1/8 11167 60 1/4 8142 66 1/4 9040 72 1/4 9865 78 1/4 10590 84 1/4 11178 60 3/8 8161 66 3/8 9058 72 3/8 9882 78 3/8 10604 84 3/8 11188 60 1/2 8180 66 1/2 9076 72 1/2 9898 78 1/2 10618 84 1/2 11199 60 5/8 8200 66 5/8 9094 72 5/8 9914 78 5/8 10632 84 5/8 11209 60 3/4 8219 66 3/4 9112 72 3/4 9930 78 3/4 10645 84 3/4 11219 60 7/8 8238 66 7/8 9130 72 7/8 9946 78 7/8 10659 84 7/8 11229 61 8257 67 9148 73 9962 79 10672 85 11239 61 1/8 8276 67 1/8 9165 73 1/8 9978 79 1/8 10686 85 1/8 11249 61 1/4 8295 67 1/4 9183 73 1/4 9994 79 1/4 10699 85 1/4 11259 61 3/8 8315 67 3/8 9201 73 3/8 10010 79 3/8 10712 85 3/8 11269 61 1/2 8334 67 1/2 9219 73 1/2 10026 79 1/2 10726 85 1/2 11278 61 5/8 8353 67 5/8 9236 73 5/8 10042 79 5/8 10739 85 5/8 11288 61 3/4 8372 67 3/4 9254 73 3/4 10057 79 3/4 10752 85 3/4 11297 61 7/8 8391 67 7/8 9272 73 7/8 10073 79 7/8 10765 85 7/8 11306 62 8410 68 9289 74 10089 80 10778 86 11316 62 1/8 8429 68 1/8 9307 74 1/8 10104 80 1/8 10791 86 1/8 11325 62 1/4 8448 68 1/4 9324 74 1/4 10120 80 1/4 10804 86 1/4 11334 62 3/8 8467 68 3/8 9342 74 3/8 10135 80 3/8 10817 86 3/8 11343 62 1/2 8486 68 1/2 9359 74 1/2 10151 80 1/2 10829 86 1/2 11352 62 5/8 8504 68 5/8 9377 74 5/8 10166 80 5/8 10842 86 5/8 11360 62 3/4 8523 68 3/4 9394 74 3/4 10182 80 3/4 10855 86 3/4 11369 62 7/8 8542 68 7/8 9412 74 7/8 10197 80 7/8 10867 86 7/8 11377 63 8561 69 9429 75 10212 81 10880 87 11386 63 1/8 8580 69 1/8 9446 75 1/8 10227 81 1/8 10892 87 1/8 11394 63 1/4 8598 69 1/4 9463 75 1/4 10242 81 1/4 10904 87 1/4 11402 63 3/8 8617 69 3/8 9481 75 3/8 10258 81 3/8 10917 87 3/8 11410 63 1/2 8636 69 1/2 9498 75 1/2 10273 81 1/2 10929 87 1/2 1141863 1/2 8636 69 1/2 9498 75 1/2 10273 81 1/2 10929 87 1/2 11418 63 5/8 8654 69 5/8 9515 75 5/8 10288 81 5/8 10941 87 5/8 11426 63 3/4 8673 69 3/4 9532 75 3/4 10303 81 3/4 10953 87 3/4 11434 63 7/8 8692 69 7/8 9549 75 7/8 10318 81 7/8 10965 87 7/8 11441 64 8710 70 9566 76 10332 82 10977 88 11449 64 1/8 8729 70 1/8 9583 76 1/8 10347 82 1/8 10989 88 1/8 11456 64 1/4 8747 70 1/4 9600 76 1/4 10362 82 1/4 11000 88 1/4 11464 64 3/8 8766 70 3/8 9617 76 3/8 10377 82 3/8 11012 88 3/8 11471 64 1/2 8784 70 1/2 9634 76 1/2 10391 82 1/2 11024 88 1/2 11478 64 5/8 8803 70 5/8 9651 76 5/8 10406 82 5/8 11035 88 5/8 11484 64 3/4 8821 70 3/4 9667 76 3/4 10420 82 3/4 11047 88 3/4 11491 64 7/8 8840 70 7/8 9684 76 7/8 10435 82 7/8 11058 88 7/8 11498 65 8858 71 9701 77 10449 83 11069 89 11504 65 1/8 8876 71 1/8 9717 77 1/8 10464 83 1/8 11081 89 1/8 11510 65 1/4 8895 71 1/4 9734 77 1/4 10478 83 1/4 11092 89 1/4 11517 65 3/8 8913 71 3/8 9751 77 3/8 10492 83 3/8 11103 89 3/8 11522 65 1/2 8931 71 1/2 9767 77 1/2 10506 83 1/2 11114 89 1/2 11528 65 5/8 8949 71 5/8 9784 77 5/8 10521 83 5/8 11125 89 5/8 11534 65 3/4 8968 71 3/4 9800 77 3/4 10535 83 3/4 11135 89 3/4 11539 65 7/8 8986 71 7/8 9816 77 7/8 10549 83 7/8 11146 89 7/8 11545 66 9004 72 9833 78 10563 84 11157 90 11550 3 8' 12000 DWT6 Double Wall Tank 11595 Gals DIPSTICK GALLONS 90 1/8 11555 90 1/4 11560 90 3/8 11564 90 1/2 11568 90 5/8 11573 90 3/4 11576 90 7/8 11580 91 11583 91 1/8 11586 91 1/4 11589 91 3/8 11592 91 1/2 11593 91 5/8 11595 4