Loading...
HomeMy WebLinkAbout2022 Results1 Jennifer Pruitt Subject:SA002, AT&T Sensor & Probe Certification w/Overfill Test - PO- (BKFDCA01), Bakersfield Location:1520 20TH ST, BAKERSFIELD, CA 93301-4406 Start:Thu 1/27/2022 11:00 AM End:Thu 1/27/2022 1:00 PM Recurrence:(none) Meeting Status:Meeting organizer Organizer:Simplex Communication Required Attendees:AGUILAR, ADOLFO; Thompson, Alton Duke (at5145@att.com); 'FLORES, CECILIA'; AT&T CA Testing; 'HAYN, CINDY H (ATTSI)' (ch1921@att.com) ; Carlos Cardenas; Jennifer Pruitt; Maria Figueroa; Krystine Gossett; Alan Throckmorton; Erin Langford; Randy Novak; James Livoni Categories:Overfill Alarm Testing, Sensor(s) Certification, Probe Certification, Legacy T Site There is an AT&T Sensor & Probe Certification scheduled for this location on the date and time indicated. NOTE: -PO-TBD -Recertify the new probe -Recertify the new 208 Fill Sump Sensor -Permit Required for repairs made -Permit # N/A -Testing will include the Overfill Test of the Overfill alarm SA002 1520 20TH ST BAKERSFIELD 93301-4406     Please contact the Compliance Manager with any questions and/or comments at:  simplexcommunication@tait.com    714.560.8200    Environmental Health/CUPA Contact Information:   Bakersfield City Fire Department  2101 H Street  Bakersfield, CA 93301  Method of Notification: Email  Contact: Peter Armagost parmagost@bakersfieldfire.us    Test Results Submittal: USTResults@bakersfieldfire.us    1 Jennifer Pruitt From:Mart Brownfield <mbrownfield@bakersfieldfire.us> Sent:Monday, January 24, 2022 9:39 AM To:Carlos Cardenas Cc:Peter Armagost; Jennifer Pruitt; ADOLFO; Alan Throckmorton; Erin Langford; Randy Novak Subject:Re: [External] AT&T - SA004 1918 "M" Street - Bakersfield CA & AT&T SA002 - 1520 20th Street Bakersfield, CA Carlos,    11:00 AM on Thursday January 27th 2022 will work just fine for SA002 ‐ 1520 20th Street.    Marty     From: Carlos Cardenas <ccardenas@TAIT.COM>  Sent: Saturday, January 22, 2022 12:23 AM  To: Mart Brownfield <mbrownfield@bakersfieldfire.us>  Cc: Peter Armagost <parmagost@bakersfieldfire.us>; Jennifer Pruitt <jpruitt@TAIT.COM>; ADOLFO <aa376w@att.com>; Alan  Throckmorton <alant@TAIT.COM>; Erin Langford <elangford@TAIT.COM>; Randy Novak <rnovak@TAIT.COM>  Subject: RE: AT&T ‐ SA004 1918 "M" Street ‐ Bakersfield CA & AT&T SA002 ‐ 1520 20th Street Bakersfield, CA      Thank you for the response Inspector Brownfield. We actually plan on the repair and retesting for SA002 to be on 1/27/2022  11:00 AM, if that works for you? The technician for SA004 on the 28th is driving down from Northern California, so his day is a  little more restricted.     Carlos E. Cardenas  Tait Environmental Services, Inc.  (714) 567-6418     From: Mart Brownfield <mbrownfield@bakersfieldfire.us>   Sent: Friday, January 21, 2022 2:13 PM  To: Carlos Cardenas <ccardenas@TAIT.COM>  Cc: Peter Armagost <parmagost@bakersfieldfire.us>; Jennifer Pruitt <jpruitt@TAIT.COM>; ADOLFO <aa376w@att.com>; Alan  Throckmorton <alant@TAIT.COM>; Erin Langford <elangford@TAIT.COM>; Randy Novak <rnovak@TAIT.COM>  Subject: [External] AT&T ‐ SA004 1918 "M" Street ‐ Bakersfield CA & AT&T SA002 ‐ 1520 20th Street Bakersfield, CA      Carlos,  I have you approved permit application for the installation of check valves on the turbine for the AT&T SA004 located  at 1918 M Street.   I can accommodate the test request for that facility on January 28th.      We also have an open & outstanding minor modification permit for the AT&T SA002 located at 1520 20th Street. This  permit is for the replacement of a Veeder Root 208 Sump Sensor.  Would you like to take care of this permit as well on the 28th?      Please let me know.     Thanks,     2 Marty   Appendix VI Underground Storage Tank Monitoring System Certification Form CERS = California Environmental Reporting System, GPH = Gallons Per Hour, ID = Identification, ICC = International Code Council, LLD = Line Leak Detector, NA = Not Applicable, SW = Single- Walled, UDC = Under-Dispenser Containment, UST = Underground Storage Tank, VPH = Vacuum/Pressure/Hydrostatic Page 1 of 6 TYPE OF ACTION ܆܆ Installation ܆ Repair ܆ 12 Month 1. FACILITY INFORMATION CERS ID Certification Date Facility Name Facility Address City ZIP Code 2. SERVICE TECHNICIAN INFORMATION Company Performing the Certification Phone Mailing Address Service Technician Performing Test Contractor/Tank Tester License Number ICC Number ICC Expiration Date 3. TRAINING AND CERTIFICATIONS Manufacturer and Test Equipment Training Certifications Expiration Date 4. CERTIFICATION BY SERVICE TECHNICIAN CONDUCTING TEST I hereby certify that the monitoring system is operational in accordance with California Code of Regulations, title 23, division 3, chapter 16, section 2638; that required supporting documentation is attached; and all information contained herein is accurate. Service Technician Signature Date Total # of Pages SA002 10029370 01/27/2022 Pacific Bell Telephone Co. dba AT&T California 1520 20th St.Bakersfield 93301 TAIT Environmental Services, Inc. (714) 560-8222 701 N. Parkcenter Dr., Santa Ana, CA 92705 James livoni 588098 5272568 12-6-2023 Veeder Root A26911 3-23-2023 01/27/2022 Underground Storage Tank Monitoring System Certification Form Page 2 of 6 5. MONITORING SYSTEM AND PROGRAMMING A separate Monitoring System Certification Form must be prepared for each control panel. Make of Monitoring System Control Panel Model of Monitoring System Control Panel Software Version Installed Attach the post-certification reports if the monitoring system is capable of generating either;܆܆Monitoring System Set-up ܆܆ Alarm History Report Yes No NA All monitoring equipment is operational per manufacturer’s specifications?܆܆܆܆ Secondary containment systems are free of damage, debris, or liquid?܆܆܆܆ Are the audible and visual alarms operational?܆܆܆܆ All sensors have been: 1) visually inspected for wiring kinks, breaks and residual buildup on floats; and 2) tested for functionality and confirmed operational?܆܆܆܆܆܆ Are all sensors installed to detect a release at the earliest opportunity in the secondary containment?܆܆܆܆܆܆ The monitoring system set-up was reviewed, and proper settings confirmed?܆܆܆܆܆܆ Was the monitoring control panel’s backup battery visually inspected, functionally tested, and confirmed operational?܆܆܆܆܆܆ Does the flow of fuel stop at the dispenser if a release is detected in the under- dispenser containment?܆܆܆܆܆܆ Does the turbine automatically shut down if the piping secondary containment monitoring system fails to operate or is electrically disconnected?܆܆܆܆܆܆ Does the turbine automatically shut down if the piping secondary containment monitoring system detects a release? Which sensors initiate positive shut down? (Check all that apply)܆ Sump ܆ UDC ܆܆܆܆܆܆ If monitoring system alarms are relayed to a remote monitoring center, is all communication equipment operational?܆܆܆܆܆܆ Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 Veeder Root TLS350 plus 120.00 ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ Underground Storage Tank Monitoring System Certification Form Page 3 of 6 6. SENSOR TESTING RESULTS List only sensors tested on date of this certification. List “Sensor ID” as labeled in system programming. Additional copies of this page may be attached to accommodate all sensors tested. Sensor ID Sensor Model Component(s) Monitored Pass Fail ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 L-1 fill sump 794380-208 / N/A Fill sump ✔ Underground Storage Tank Monitoring System Certification Form Page 4 of 6 7. LINE LEAK DETECTOR TESTING ܆܆ Check this box if line leak detectors ARE NOT installed. (Do not complete this section.) Simulated release rate verified: (Check all that apply.) ܆܆ 3 GPH ܆܆ 0.1 GPH ܆܆ 0.2 GPH Yes No NA Has the testing apparatus been properly calibrated?܆܆ ܆܆ ܆܆ For emergency generator tank systems, does the LLD create an audible and visual alarm when a leak is detected?܆܆ ܆܆ ܆܆ For mechanical LLDs, does the LLD restrict the flow through the pipe when a release is detected?܆܆ ܆܆ ܆܆ For electronic LLDs, does the turbine automatically shut off when a release is detected?܆܆ ܆܆ ܆܆ For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system is disabled or disconnected?܆܆ ܆܆ ܆܆ For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system malfunctions or fails a tightness test?܆܆ ܆܆ ܆܆ For electronic LLDs, have all accessible wiring connections been visually inspected for kinks and breaks?܆܆ ܆܆ ܆܆ Were all items on the equipment manufacturer’s maintenance checklist completed?܆܆ ܆܆ ܆܆ Were all LLDs confirmed operational within regulatory requirements?܆܆ ܆܆ ܆܆ LLD ID LLD Model Lines Monitored Pass Fail ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 ✔ Underground Storage Tank Monitoring System Certification Form Page 5 of 6 8. IN-TANK GAUGING TESTING ܆܆ Check this box if tank gauging is used only for inventory control. ܆܆ Check this box if NO tank gauging equipment is installed. (Do not complete this section if either box is checked.) Yes No NA All wiring has been: 1) visually inspected for kinks, breaks and proper entry and termination; and 2) tested for ground faults?܆܆ ܆܆ ܆܆ Were all in-tank gauging probes visually inspected for damage and residue buildup to ensure that floats move freely, functionally tested, and confirmed operational?܆܆ ܆܆ ܆܆ Was accuracy of system’s product level readings tested?܆܆ ܆܆ ܆܆ Was accuracy of system’s water level readings tested?܆܆ ܆܆ ܆܆ Were all probes reinstalled properly?܆܆ ܆܆ ܆܆ Were all items on the equipment manufacturer’s maintenance checklist completed?܆܆ ܆܆ ܆܆ Probe ID Probe Model Tanks Monitored Pass Fail ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ 9. COMMENTS Describe all answers marked “No” or “Fail” and proposed remedy. List all monitoring equipment either replaced or repaired. ✔ ✔ ✔ ✔ ✔ ✔ ✔ T-1 846396-105/466393 SA002U001 ✔ New probe. Underground Storage Tank Monitoring System Certification Form Page 6 of 6 10. MONITORING SITE PLAN Date site plan was prepared: If a site plan has been prepared that shows all required information, you may include it, rather than this page, with your Monitoring System Certification Form. The site plan must show the general layout of tanks and identify locations of the monitoring panel, and all leak detection equipment and monitoring locations. Include a legend for all symbols depicted. 01/27/2022 Appendix IX Underground Storage Tank Overfill Prevention Equipment Inspection Report Form CERS = California Environmental Reporting System, ID = Identification, ICC = International Code Council, OPE = Overfill Prevention Equipment Page 1 of 2 TYPE OF ACTION ܆܆ Installation ܆ Repair ܆ 36 Month 1. FACILITY INFORMATION CERS ID Inspection Date Facility Name Facility Address City ZIP Code 2. SERVICE TECHNICIAN INFORMATION Company Performing the Inspection Phone Mailing Address Service Technician Performing Inspection Contractor/Tank Tester License Number ICC Number Expiration Date 3. TRAINING AND CERTIFICATIONS Manufacturer and Test Equipment Training Certifications Expiration Date 4. INSPECTION PROCEDURES INFORMATION Inspection Procedures Used Components Inspected 5. CERTIFICATION BY SERVICE TECHNICIAN CONDUCTING INSPECTION I hereby certify that the OPE was inspected in accordance with California Code of Regulations, title 23, division 3, chapter 16, section 2637.2; that required supporting documentation is attached; and all information contained herein is accurate. I understand that test procedures shall be made available upon request by the governing authority. Service Technician Signature Date Total # of Pages SA002 10029370 1/27/2022 Pacific Bell Telephone Co. dba AT&T California 1520 20th St. Bakersfield 93301 TAIT Environmental Services, Inc. (714) 560-8222 701 N. Parkcenter Dr., Santa Ana, CA 92705 James Livoni 588098 5272568 12-6-2023 Veeder Root A26911 3-23-2023 Manufacture guidelines SA002U001 846396-105/466393 1/27/2022 Underground Storage Tank Overfill Prevention Equipment Inspection Report Additional copies of this page may be attached. Attach tank chart(s), measurements, calculations, and In-Tank Setup report(s) Page 2 of 2 6. OVERFILL PREVENTION EQUIPMENT DETAILS Tank ID (one OPE per column) Are both vent and tank riser piping secondarily contained? ܆܆ Yes ܆܆ No ܆܆ Yes ܆܆ No ܆܆ Yes ܆܆ No ܆܆ Yes ܆܆ No OPE Model What is the OPE response when activated? (Check all that apply.) ܆܆ Shut off Flow ܆܆Restricts Flow ܆܆ Audible Alarm ܆܆ Visual Alarm ܆܆ Shut off Flow ܆܆Restricts Flow ܆܆ Audible Alarm ܆܆ Visual Alarm ܆܆ Shut off Flow ܆܆Restricts Flow ܆܆ Audible Alarm ܆܆ Visual Alarm ܆܆ Shut off Flow ܆܆Restricts Flow ܆܆ Audible Alarm ܆܆ Visual Alarm Are flow restrictors installed on vent piping that may interfere with the OPE operation? ܆܆ Yes ܆܆ No ܆܆ Yes ܆܆ No ܆܆ Yes ܆܆ No ܆܆ Yes ܆܆ No At what level in the tank is the OPE set to activate? (Inches from bottom of tank) What is the percent capacity of the tank at which the OPE activates? Is the OPE in proper operating condition to respond when the stored substance reaches the designated regulatory level? ܆܆ Yes ܆܆ No ܆܆ Yes ܆܆ No ܆܆ Yes ܆܆ No ܆܆ Yes ܆܆ No 7. SUMMARY OF TESTING RESULTS OPE Inspection Results ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail 1 8. COMMENTS Describe all results marked “Fail” and each proposed remedy. * Mark here if: ܆܆ Flow restrictors interfere with overfill prevention and equipment repairs required. SA002U001 ✔ 846396-105 ✔ ✔ 69.25" 90 ✔ ✔ New probe I50301 FEB 2, 2022 12:59 PM # 1:BKFDCA01 SA002 T-S I50302 FEB 2, 2022 12:59 PM # 2:1520 20TH ST I50303 FEB 2, 2022 12:59 PM # 3:BAKERSFIELD,CA 93301 I50304 FEB 2, 2022 12:59 PM # 4:661-869-1846 I51700 FEB 2, 2022 12:59 PM SYSTEM TYPE AND LANGUAGE FLAG SYSTEM UNITS U.S. SYSTEM LANGUAGE ENGLISH SYSTEM DATE/TIME FORMAT MON DD YYYY HH:MM:SS xM I50F00 FEB 2, 2022 1:00 PM MON DD YYYY HH:MM:SS xM I10200 FEB 2, 2022 1:00 PM BKFDCA01 SA002 T-S 1520 20TH ST BAKERSFIELD,CA 93301 661-869-1846 SYSTEM CONFIGURATION SLOT BOARD TYPE POWER ON RESET CURRENT 1 4 PROBE / G.T. 162295 162246 2 INTERSTITIAL BD 201439 201464 3 UNUSED 15000000 15000000 4 UNUSED 15000000 15000000 5 UNUSED 15000000 15000000 6 UNUSED 15000000 15000000 7 UNUSED 15000000 15000000 8 UNUSED 15000000 15000000 9 RELAY BOARD 14933 14962 10 COMBO I/O BOARD 9929 9924 11 UNUSED 15000000 15000000 12 UNUSED 15000000 15000000 13 UNUSED 15000000 15000000 14 UNUSED 15000000 15000000 15 UNUSED 15000000 15000000 16 UNUSED 15000000 15000000 COMM 1 FAXMODEM BOARD 40571 40597 COMM 2 UNUSED 15000000 15000000 COMM 3 UNUSED 15000000 15000000 COMM 4 UNUSED 15000000 15000000 COMM 5 UNUSED 15000000 15000000 COMM 6 UNUSED 15000000 15000000 I60100 FEB 2, 2022 1:00 PM TANK CONFIGURATION DEVICE LABEL CONFIGURED 1 DIESEL TK#SA002U001 ON 2 DIESEL TK#SA002A002 ON 3 OFF 4 OFF I60200 FEB 2, 2022 1:00 PM TANK PRODUCT LABEL TANK PRODUCT LABEL 1 DIESEL TK#SA002U001 2 DIESEL TK#SA002A002 3 4 I60300 FEB 2, 2022 1:00 PM TANK PRODUCT CODE TANK PRODUCT LABEL 1 DIESEL TK#SA002U001 1 2 DIESEL TK#SA002A002 1 3 3 4 4 I60400 FEB 2, 2022 1:00 PM TANK FULL VOLUME TANK PRODUCT LABEL GALLONS 1 DIESEL TK#SA002U001 8002 2 DIESEL TK#SA002A002 250 3 0 4 0 I60700 FEB 2, 2022 1:00 PM TANK DIAMETER TANK PRODUCT LABEL INCHES 1 DIESEL TK#SA002U001 82.00 2 DIESEL TK#SA002A002 30.00 3 0.00 4 0.00 I60900 FEB 2, 2022 1:00 PM TANK THERMAL COEFFICIENT TANK PRODUCT LABEL 1 DIESEL TK#SA002U001 0.000450 2 DIESEL TK#SA002A002 0.000450 3 0.000000 4 0.000000 I61200 FEB 2, 2022 1:00 PM TANK MANIFOLDED PARTNERS TANK PRODUCT LABEL MANIFOLDED TANKS 1 DIESEL TK#SA002U001 NONE 2 DIESEL TK#SA002A002 NONE 3 NONE 4 NONE I62100 FEB 2, 2022 1:00 PM TANK LOW PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 DIESEL TK#SA002U001 4000 2 DIESEL TK#SA002A002 105 3 0 4 0 I62200 FEB 2, 2022 1:00 PM TANK HIGH PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 DIESEL TK#SA002U001 7601 2 DIESEL TK#SA002A002 237 3 0 4 0 I62300 FEB 2, 2022 1:00 PM TANK OVERFILL LEVEL LIMIT TANK PRODUCT LABEL GALLONS 1 DIESEL TK#SA002U001 7201 2 DIESEL TK#SA002A002 225 3 0 4 0 I62400 FEB 2, 2022 1:01 PM TANK HIGH WATER LEVEL LIMIT TANK PRODUCT LABEL INCHES 1 DIESEL TK#SA002U001 2.0 2 DIESEL TK#SA002A002 2.0 I62800 FEB 2, 2022 1:01 PM TANK MAXIMUM VOLUME LIMIT TANK PRODUCT LABEL GALLONS 1 DIESEL TK#SA002U001 8002 2 DIESEL TK#SA002A002 250 3 0 4 0 I62900 FEB 2, 2022 1:01 PM TANK DELIVERY REQUIRED LIMIT TANK PRODUCT LABEL GALLONS 1 DIESEL TK#SA002U001 4000 2 DIESEL TK#SA002A002 125 3 0 4 0 I70300 FEB 2, 2022 1:01 PM LIQUID TYPE SENSOR LOCATION TYPE 1 FILL SUMP TRI-STATE (SINGLE FLOAT) 2 PIPING SUMP TRI-STATE (SINGLE FLOAT) 3 DAYTANK RUPTURE BASN TRI-STATE (SINGLE FLOAT) 4 DAY TANK ANNULAR TRI-STATE (SINGLE FLOAT) 5 ANNULAR UST TRI-STATE (SINGLE FLOAT) 6 TRANSITION SUMP TRI-STATE (SINGLE FLOAT) 7 REMOTE PUMP CABINET TRI-STATE (SINGLE FLOAT) 8 TRI-STATE (SINGLE FLOAT) I90200 FEB 2, 2022 1:01 PM SOFTWARE REVISION LEVEL VERSION 120.00 SOFTWARE# 346120-100-A CREATED - 00.07.28.15.33 S-MODULE# 330160-002-A SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS CSLD I11100 FEB 2, 2022 1:01 PM BKFDCA01 SA002 T-S 1520 20TH ST BAKERSFIELD,CA 93301 661-869-1846 PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME T 1 TANK DIESEL TK#SA002U001 PROBE OUT CLEAR 1-27-22 12:11PM T 1 TANK DIESEL TK#SA002U001 PROBE OUT ALARM 1-27-22 12:11PM T 1 TANK DIESEL TK#SA002U001 OVERFILL ALARM CLEAR 1-27-22 12:10PM T 1 TANK DIESEL TK#SA002U001 OVERFILL ALARM ALARM 1-27-22 12:08PM L 1 STP SUMP FILL SUMP FUEL ALARM CLEAR 1-27-22 12:07PM L 1 STP SUMP FILL SUMP FUEL ALARM ALARM 1-27-22 12:07PM T 1 TANK DIESEL TK#SA002U001 OVERFILL ALARM CLEAR 1-27-22 10:38AM T 1 TANK DIESEL TK#SA002U001 OVERFILL ALARM ALARM 1-27-22 10:36AM T 1 TANK DIESEL TK#SA002U001 LOW PRODUCT ALARM CLEAR 1-27-22 10:26AM T 1 TANK DIESEL TK#SA002U001 LOW PRODUCT ALARM ALARM 1-27-22 10:23AM T 1 TANK DIESEL TK#SA002U001 PROBE OUT CLEAR 1-27-22 10:23AM T 1 TANK DIESEL TK#SA002U001 PROBE OUT ALARM 1-27-22 10:18AM L 1 STP SUMP FILL SUMP FUEL ALARM CLEAR 12-31-21 9:22AM T 1 TANK DIESEL TK#SA002U001 PROBE OUT CLEAR 12-31-21 9:05AM T 1 TANK DIESEL TK#SA002U001 LOW PRODUCT ALARM CLEAR 12-31-21 9:05AM L 1 STP SUMP FILL SUMP SENSOR OUT ALARM CLEAR 12-31-21 6:22AM L 1 STP SUMP FILL SUMP FUEL ALARM ALARM 12-31-21 6:22AM L 1 STP SUMP FILL SUMP SENSOR OUT ALARM ALARM 12-31-21 6:21AM L 1 STP SUMP FILL SUMP FUEL ALARM CLEAR 12-31-21 6:21AM L 1 STP SUMP FILL SUMP SENSOR OUT ALARM CLEAR 12-31-21 5:38AM L 1 STP SUMP FILL SUMP FUEL ALARM ALARM 12-31-21 5:38AM L 1 STP SUMP FILL SUMP SENSOR OUT ALARM ALARM 12-31-21 5:38AM L 1 STP SUMP FILL SUMP FUEL ALARM CLEAR 12-31-21 5:38AM L 1 STP SUMP FILL SUMP SENSOR OUT ALARM CLEAR 12-31-21 4:57AM L 1 STP SUMP FILL SUMP FUEL ALARM ALARM 12-31-21 4:57AM L 1 STP SUMP FILL SUMP SENSOR OUT ALARM ALARM 12-30-21 11:54PM L 1 STP SUMP FILL SUMP FUEL ALARM CLEAR 12-30-21 11:54PM L 1 STP SUMP FILL SUMP FUEL ALARM ALARM 12-30-21 11:54PM T 1 TANK DIESEL TK#SA002U001 PROBE OUT ALARM 12-30-21 11:47PM T 1 TANK DIESEL TK#SA002U001 LOW PRODUCT ALARM ALARM 12-30-21 11:47PM D 1 OTHER CALL CENTER AUTODIAL FAILURE CLEAR 10-29-21 10:05AM D 1 OTHER CALL CENTER AUTODIAL FAILURE ALARM 10-29-21 10:02AM D 1 OTHER CALL CENTER AUTODIAL FAILURE CLEAR 10-29-21 9:48AM T 2 TANK DIESEL TK#SA002A002 HIGH WATER ALARM CLEAR 10-29-21 9:43AM T 2 TANK DIESEL TK#SA002A002 PROBE OUT CLEAR 10-29-21 9:43AM T 2 TANK DIESEL TK#SA002A002 PROBE OUT ALARM 10-29-21 9:42AM T 2 TANK DIESEL TK#SA002A002 HIGH WATER ALARM ALARM 10-29-21 9:40AM T 2 TANK DIESEL TK#SA002A002 MAX PRODUCT ALARM CLEAR 10-29-21 9:35AM T 2 TANK DIESEL TK#SA002A002 MAX PRODUCT ALARM ALARM 10-29-21 9:35AM T 2 TANK DIESEL TK#SA002A002 MAX PRODUCT ALARM CLEAR 10-29-21 9:33AM T 2 TANK DIESEL TK#SA002A002 MAX PRODUCT ALARM ALARM 10-29-21 9:33AM T 2 TANK DIESEL TK#SA002A002 PROBE OUT CLEAR 10-29-21 9:33AM T 2 TANK DIESEL TK#SA002A002 PROBE OUT ALARM 10-29-21 9:31AM D 1 OTHER CALL CENTER AUTODIAL FAILURE ALARM 10-29-21 9:29AM D 1 OTHER CALL CENTER AUTODIAL FAILURE CLEAR 10-29-21 9:29AM L 3 OTHER DAYTANK RUPTURE BASN FUEL ALARM CLEAR 10-29-21 9:29AM L 3 OTHER DAYTANK RUPTURE BASN FUEL ALARM ALARM 10-29-21 9:29AM L 4 ANNULAR DAY TANK ANNULAR FUEL ALARM CLEAR 10-29-21 9:27AM L 4 ANNULAR DAY TANK ANNULAR FUEL ALARM ALARM 10-29-21 9:27AM T 1 TANK DIESEL TK#SA002U001 HIGH WATER ALARM CLEAR 10-29-21 9:20AM I11200 FEB 2, 2022 1:02 PM BKFDCA01 SA002 T-S 1520 20TH ST BAKERSFIELD,CA 93301 661-869-1846 NON-PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME T 1 TANK DIESEL TK#SA002U001 LOW TEMP WARNING CLEAR 1-27-22 12:13PM T 1 TANK DIESEL TK#SA002U001 LOW TEMP WARNING ALARM 1-27-22 12:12PM T 1 TANK DIESEL TK#SA002U001 DELIVERY NEEDED CLEAR 1-27-22 10:26AM T 1 TANK DIESEL TK#SA002U001 DELIVERY NEEDED ALARM 1-27-22 10:23AM L 1 STP SUMP FILL SUMP SETUP DATA WARNING CLEAR 1-01-22 9:06AM L 1 STP SUMP FILL SUMP SETUP DATA WARNING ALARM 1-01-22 8:19AM L 1 STP SUMP FILL SUMP SETUP DATA WARNING CLEAR 1-01-22 8:16AM L 1 STP SUMP FILL SUMP SETUP DATA WARNING ALARM 1-01-22 7:53AM L 1 STP SUMP FILL SUMP SETUP DATA WARNING CLEAR 12-31-21 6:37PM L 1 STP SUMP FILL SUMP SETUP DATA WARNING ALARM 12-31-21 6:36PM L 1 STP SUMP FILL SUMP SETUP DATA WARNING CLEAR 12-31-21 6:36PM L 1 STP SUMP FILL SUMP SETUP DATA WARNING ALARM 12-31-21 4:59PM L 1 STP SUMP FILL SUMP SETUP DATA WARNING CLEAR 12-31-21 4:49PM L 1 STP SUMP FILL SUMP SETUP DATA WARNING ALARM 12-31-21 4:48PM L 1 STP SUMP FILL SUMP SETUP DATA WARNING CLEAR 12-31-21 4:34PM L 1 STP SUMP FILL SUMP SETUP DATA WARNING ALARM 12-31-21 4:32PM L 1 STP SUMP FILL SUMP SETUP DATA WARNING CLEAR 12-31-21 4:32PM L 1 STP SUMP FILL SUMP SETUP DATA WARNING ALARM 12-31-21 4:32PM L 1 STP SUMP FILL SUMP SETUP DATA WARNING CLEAR 12-31-21 4:32PM L 1 STP SUMP FILL SUMP SETUP DATA WARNING ALARM 12-31-21 4:32PM L 1 STP SUMP FILL SUMP SETUP DATA WARNING CLEAR 12-31-21 4:32PM L 1 STP SUMP FILL SUMP SETUP DATA WARNING ALARM 12-31-21 4:32PM L 1 STP SUMP FILL SUMP SETUP DATA WARNING CLEAR 12-31-21 4:32PM L 1 STP SUMP FILL SUMP SETUP DATA WARNING ALARM 12-31-21 4:32PM L 1 STP SUMP FILL SUMP SETUP DATA WARNING CLEAR 12-31-21 4:32PM L 1 STP SUMP FILL SUMP SETUP DATA WARNING ALARM 12-31-21 4:32PM L 1 STP SUMP FILL SUMP SETUP DATA WARNING CLEAR 12-31-21 3:57PM L 1 STP SUMP FILL SUMP SETUP DATA WARNING ALARM 12-31-21 3:51PM L 1 STP SUMP FILL SUMP SETUP DATA WARNING CLEAR 12-31-21 3:51PM L 1 STP SUMP FILL SUMP SETUP DATA WARNING ALARM 12-31-21 1:07PM L 1 STP SUMP FILL SUMP SETUP DATA WARNING CLEAR 12-31-21 1:07PM L 1 STP SUMP FILL SUMP SETUP DATA WARNING ALARM 12-31-21 1:07PM L 1 STP SUMP FILL SUMP SETUP DATA WARNING CLEAR 12-31-21 1:07PM L 1 STP SUMP FILL SUMP SETUP DATA WARNING ALARM 12-31-21 11:50AM L 1 STP SUMP FILL SUMP SETUP DATA WARNING CLEAR 12-31-21 11:50AM L 1 STP SUMP FILL SUMP SETUP DATA WARNING ALARM 12-31-21 11:50AM L 1 STP SUMP FILL SUMP SETUP DATA WARNING CLEAR 12-31-21 11:49AM L 1 STP SUMP FILL SUMP SETUP DATA WARNING ALARM 12-31-21 11:49AM L 1 STP SUMP FILL SUMP SETUP DATA WARNING CLEAR 12-31-21 11:49AM L 1 STP SUMP FILL SUMP SETUP DATA WARNING ALARM 12-31-21 11:49AM L 1 STP SUMP FILL SUMP SETUP DATA WARNING CLEAR 12-31-21 11:49AM L 1 STP SUMP FILL SUMP SETUP DATA WARNING ALARM 12-31-21 11:48AM L 1 STP SUMP FILL SUMP SETUP DATA WARNING CLEAR 12-31-21 11:48AM L 1 STP SUMP FILL SUMP SETUP DATA WARNING ALARM 12-31-21 10:03AM L 1 STP SUMP FILL SUMP SETUP DATA WARNING CLEAR 12-31-21 10:03AM L 1 STP SUMP FILL SUMP SETUP DATA WARNING ALARM 12-31-21 9:22AM T 1 TANK DIESEL TK#SA002U001 DELIVERY NEEDED CLEAR 12-31-21 9:05AM T 1 TANK DIESEL TK#SA002U001 DELIVERY NEEDED ALARM 12-30-21 11:47PM T 2 TANK DIESEL TK#SA002A002 HIGH WATER WARNING CLEAR 10-29-21 9:43AM T 2 TANK DIESEL TK#SA002A002 HIGH WATER WARNING ALARM 10-29-21 9:40AM I20600 FEB 2, 2022 1:03 PM BKFDCA01 SA002 T-S 1520 20TH ST BAKERSFIELD,CA 93301 661-869-1846 TANK ALARM HISTORY TANK 1 DIESEL TK#SA002U001 LEAK ALARM OCT 11, 2011 6:08 AM OCT 14, 2010 2:44 PM OCT 13, 2010 11:06 AM HIGH WATER ALARM OCT 29, 2021 9:17 AM OCT 15, 2020 8:33 AM OCT 23, 2019 9:04 AM OVERFILL ALARM JAN 27, 2022 12:08 PM JAN 27, 2022 10:36 AM OCT 29, 2021 9:12 AM LOW PRODUCT ALARM JAN 27, 2022 10:23 AM DEC 30, 2021 11:47 PM OCT 29, 2021 9:10 AM SUDDEN LOSS ALARM APR 4, 2010 3:43 PM FEB 19, 2010 10:08 AM FEB 19, 2010 10:05 AM HIGH PRODUCT ALARM OCT 29, 2021 9:12 AM OCT 15, 2020 9:12 AM OCT 23, 2019 9:12 AM INVALID FUEL LEVEL AUG 8, 2017 6:13 AM PROBE OUT JAN 27, 2022 12:11 PM JAN 27, 2022 10:18 AM DEC 30, 2021 11:47 PM HIGH WATER WARNING OCT 29, 2021 9:17 AM OCT 15, 2020 8:33 AM OCT 23, 2019 9:04 AM DELIVERY NEEDED JAN 27, 2022 10:23 AM DEC 30, 2021 11:47 PM OCT 29, 2021 9:10 AM MAX PRODUCT ALARM OCT 15, 2020 9:12 AM OCT 23, 2019 9:13 AM NOV 2, 2018 9:26 AM CSLD INCR RATE WARN DEC 10, 2008 9:38 AM SEP 18, 2008 10:06 AM SEP 18, 2008 6:58 AM LOW TEMP WARNING JAN 27, 2022 12:12 PM JAN 22, 2013 9:53 AM APR 4, 2010 3:48 PM TANK 2 DIESEL TK#SA002A002 SETUP DATA WARNING JAN 27, 2012 11:49 AM HIGH WATER ALARM OCT 29, 2021 9:40 AM NOV 21, 2016 10:37 AM JAN 27, 2012 11:16 AM OVERFILL ALARM OCT 23, 2019 10:26 AM NOV 2, 2018 10:38 AM NOV 21, 2016 11:18 AM LOW PRODUCT ALARM OCT 23, 2019 10:24 AM NOV 21, 2016 10:31 AM JAN 7, 2014 9:54 AM SUDDEN LOSS ALARM OCT 12, 2010 8:39 PM FEB 19, 2010 9:55 AM APR 28, 2009 11:13 AM HIGH PRODUCT ALARM OCT 29, 2021 9:35 AM OCT 29, 2021 9:33 AM OCT 15, 2020 9:46 AM INVALID FUEL LEVEL OCT 29, 2021 9:33 AM OCT 23, 2019 10:24 AM NOV 21, 2016 10:31 AM PROBE OUT OCT 29, 2021 9:42 AM OCT 29, 2021 9:31 AM OCT 15, 2020 9:49 AM HIGH WATER WARNING OCT 29, 2021 9:40 AM NOV 21, 2016 10:37 AM JAN 27, 2012 11:16 AM DELIVERY NEEDED OCT 23, 2019 10:24 AM NOV 2, 2018 10:37 AM NOV 7, 2017 1:37 PM MAX PRODUCT ALARM OCT 29, 2021 9:35 AM OCT 29, 2021 9:33 AM OCT 15, 2020 9:46 AM LOW TEMP WARNING DEC 17, 2014 11:26 AM JAN 22, 2013 10:14 AM I30200 FEB 2, 2022 1:03 PM BKFDCA01 SA002 T-S 1520 20TH ST BAKERSFIELD,CA 93301 661-869-1846 LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 FILL SUMP JAN 27, 2022 12:07 PM FUEL ALARM JAN 1, 2022 8:19 AM SETUP DATA WARNING JAN 1, 2022 7:53 AM SETUP DATA WARNING 2 PIPING SUMP OCT 29, 2021 8:37 AM FUEL ALARM OCT 25, 2021 5:05 PM FUEL ALARM OCT 15, 2020 9:08 AM FUEL ALARM 3 DAYTANK RUPTURE BASN OCT 29, 2021 9:29 AM FUEL ALARM OCT 15, 2020 9:39 AM FUEL ALARM OCT 23, 2019 10:19 AM FUEL ALARM 4 DAY TANK ANNULAR OCT 29, 2021 9:27 AM FUEL ALARM OCT 15, 2020 9:35 AM FUEL ALARM OCT 23, 2019 10:16 AM FUEL ALARM 5 ANNULAR UST OCT 29, 2021 8:40 AM FUEL ALARM OCT 15, 2020 9:00 AM FUEL ALARM OCT 23, 2019 9:02 AM FUEL ALARM 6 TRANSITION SUMP OCT 29, 2021 9:01 AM FUEL ALARM OCT 15, 2020 9:17 AM FUEL ALARM OCT 23, 2019 9:24 AM FUEL ALARM 7 REMOTE PUMP CABINET OCT 29, 2021 8:57 AM FUEL ALARM OCT 15, 2020 9:19 AM FUEL ALARM OCT 23, 2019 9:28 AM FUEL ALARM Identification of Inspection Procedures for Overfill Prevention Equipment To Whom It May Concern: Tait Environmental Services, Inc., utilizes the following procedures when conducting Overfill Prevention Equipment Inspections: 1) Drop Tubes with Overfill Prevention Valves a) Verify information based upon Manufacturer installation instructions and follow their inspection procedures. b) If manufacturer information is not available, we conduct the inspection per PEI-RP1200-17, Section 7.1 2) Audible/Visual Alarms a) Verify programming or installation per manufacturer guidelines and test the system per manufacturer specifications. b) If manufacturer information is not available, we conduct the inspection per PEI-1200-17, Section 7.3. 3) Ballfloat Inspections are conducted following the procedures in PEI-RP1200-17, Section 7.2 California Environmental Reporting System: Business Jennifer Pruitt's Account Sign Out Tools Reports Help Submittal Finished: Submittal Finished: AT&T Corp. - SA002/CAK010/USID92203AT&T Corp. - SA002/CAK010/USID92203 Home »Draft Submittal »Submittal Finished (10029370) Print Submittal You have submitted the following elements on 2/14/2022 to Bakersfield City Fire Department • Underground Storage Tanks • Facility Information What's Next? • Return to the Draft Submittal page. • Return to Facility Home. Version 3.06.0001 | Enhancements | CERS Central Diagnostics | Conditions of Use | Privacy Policy | Contact | Help California Environmental Reporting System: Business | © 2022 California Environmental Protection AgencyCERS Technical Support: Request Technical Assistance Unified Program/General Assistance: Contact your local regulator(s) Home Home SubmittalsSubmittals FacilitiesFacilities ComplianceCompliance My BusinessMy Business CERS Help Settings My Business: AT&T Corp. Page 1 of 2Submittal Finish: CERS Business 2/14/2022https://cersbusiness2.calepa.ca.gov/43557/Facility/10029370/Submittal/2084084/Finish CERS Help Settings My Business: AT&T Corp. Page 2 of 2Submittal Finish: CERS Business 2/14/2022https://cersbusiness2.calepa.ca.gov/43557/Facility/10029370/Submittal/2084084/Finish