HomeMy WebLinkAboutCold Start 2-21-22Appendix VI Underground Storage Tank Monitoring System Certification Form CERS = California Environmental Reporting System, GPH = Gallons Per Hour, ID = Identification, ICC = International Code Council, LLD = Line Leak Detector, NA = Not Applicable, SW = Single- Walled, UDC = Under-Dispenser Containment, UST = Underground Storage Tank, VPH = Vacuum/Pressure/Hydrostatic Page 1 of 6 TYPE OF ACTION ܆܆ Installation ܆ Repair ܆ 12 Month 1. FACILITY INFORMATION CERS ID Certification Date Facility Name Facility Address City ZIP Code 2. SERVICE TECHNICIAN INFORMATION Company Performing the Certification Phone Mailing Address Service Technician Performing Test Contractor/Tank Tester License Number ICC Number ICC Expiration Date 3. TRAINING AND CERTIFICATIONS Manufacturer and Test Equipment Training Certifications Expiration Date 4. CERTIFICATION BY SERVICE TECHNICIAN CONDUCTING TEST I hereby certify that the monitoring system is operational in accordance with California Code of Regulations, title 23, division 3, chapter 16, section 2638; that required supporting documentation is attached; and all information contained herein is accurate. Service Technician Signature Date Total # of Pages 02/21/2022 Jaco #5562 Fastrip #6 1640 S Chester Ave Bakersfield, Ca 93304 Confidence UST Services, Inc.(800) 339-9930 2209 Zeus Court, Bakersfield, CA 93308 Jason Woods 1073967 8492093 03/23/2023 Veeder Root C26937 07/26/2023 02/21/2022 5 Underground Storage Tank Monitoring System Certification Form Page 2 of 6 5. MONITORING SYSTEM AND PROGRAMMING A separate Monitoring System Certification Form must be prepared for each control panel. Make of Monitoring System Control Panel Model of Monitoring System Control Panel Software Version Installed Attach the post-certification reports if the monitoring system is capable of generating either; ܆܆Monitoring System Set-up ܆܆ Alarm History Report Yes No NA All monitoring equipment is operational per manufacturer’s specifications? ܆܆܆܆ Secondary containment systems are free of damage, debris, or liquid? ܆܆܆܆ Are the audible and visual alarms operational? ܆܆܆܆ All sensors have been: 1) visually inspected for wiring kinks, breaks and residual buildup on floats; and 2) tested for functionality and confirmed operational? ܆܆܆܆܆܆ Are all sensors installed to detect a release at the earliest opportunity in the secondary containment? ܆܆܆܆܆܆ The monitoring system set-up was reviewed, and proper settings confirmed? ܆܆܆܆܆܆ Was the monitoring control panel’s backup battery visually inspected, functionally tested, and confirmed operational? ܆܆܆܆܆܆ Does the flow of fuel stop at the dispenser if a release is detected in the under- dispenser containment? ܆܆܆܆܆܆ Does the turbine automatically shut down if the piping secondary containment monitoring system fails to operate or is electrically disconnected? ܆܆܆܆܆܆ Does the turbine automatically shut down if the piping secondary containment monitoring system detects a release? Which sensors initiate positive shut down? (Check all that apply) ܆ Sump ܆ UDC ܆܆܆܆܆܆ If monitoring system alarms are relayed to a remote monitoring center, is all communication equipment operational? ܆܆܆܆܆܆ Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 Veeder Root TLS 350 329.01 Underground Storage Tank Monitoring System Certification Form Page 3 of 6 6. SENSOR TESTING RESULTS List only sensors tested on date of this certification. List “Sensor ID” as labeled in system programming. Additional copies of this page may be attached to accommodate all sensors tested. Sensor ID Sensor Model Component(s) Monitored Pass Fail ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 L1 794380-208 Unleaded 1 STP Sump L2 794380-420 Unleaded 1 Annular L3 794380-208 DSL STP Sump L4 794380-420 DSL Annular L5 794380-208 PNL STP Sump L6 794380-420 PNL Annular L7 794380-208 Unleaded 2 siphon STP Sump L8 794380-420 Unleaded 2 Annular L9 794380-208 Dispenser 1/2 L10 794380-208 Dispenser 3/4 L11 794380-208 Dispenser 5/6 L12 794380-208 Dispenser 7/8 L13 794380-208 Trans piping Sump North L14 794380-208 Trans piping Sump South Underground Storage Tank Monitoring System Certification Form Page 5 of 6 8. IN-TANK GAUGING TESTING ܆܆ Check this box if tank gauging is used only for inventory control. ܆܆ Check this box if NO tank gauging equipment is installed. (Do not complete this section if either box is checked.) Yes No NA All wiring has been: 1) visually inspected for kinks, breaks and proper entry and termination; and 2) tested for ground faults? ܆܆ ܆܆ ܆܆ Were all in-tank gauging probes visually inspected for damage and residue buildup to ensure that floats move freely, functionally tested, and confirmed operational? ܆܆ ܆܆ Was accuracy of system’s product level readings tested? ܆܆ ܆܆ ܆܆ Was accuracy of system’s water level readings tested? ܆܆ ܆܆ ܆܆ Were all probes reinstalled properly? ܆܆ ܆܆ ܆܆ Were all items on the equipment manufacturer’s maintenance checklist completed? ܆܆ ܆܆ ܆܆ Probe ID Probe Model Tanks Monitored Pass Fail ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ 9. COMMENTS Describe all answers marked “No” or “Fail” and proposed remedy. List all monitoring equipment either replaced or repaired. ܆܆ Performed Electronic MC after software upgrade. Underground Storage Tank Monitoring System Certification Form Page 6 of 6 10. MONITORING SITE PLAN Date site plan was prepared: If a site plan has been prepared that shows all required information, you may include it, rather than this page, with your Monitoring System Certification Form. The site plan must show the general layout of tanks and identify locations of the monitoring panel, and all leak detection equipment and monitoring locations. Include a legend for all symbols depicted. NOPARKING ASTPL5 STPL3 STPL1 STPL7 12,000 GALLON87-1 UNLEADED 12,000 GALLON87-2 UNLEADEDSIPHON 12,000 GALLONDIESEL 12,000 GALLON91 PREMIUM VF L6 F A V L4 AF L13 L2 VF AL8 L10 L12 L11L9 L14 12 56 7 834 EXISTING BUILDING GHW PROPERTY LINE CHESTER AVE MI N G A V E PR O P E R T Y L I N E N CATCHBASINP R I C E S I G N 40 ' S T O R A G E C O N T A I N E R DUMPSTER ALLEYALLEY LEGEND L1 87-1 STP L2 87-1 ANNULAR L3 DSL STP L4 DSL ANNULAR L5 91 STP L6 91 ANNULAR L7 87-2 SIPHON STP L8 87-2 ANNULAR L9 UDC 1 - 2 L10 UDC 3 - 4 L11 UDC 5 - 6 L12 UDC 7 - 8 L13 N TRANS SUMP L14 S TRANS SUMP 87 GAS 3/2 INCH DBL WALLED PIPE 91 GAS 3/2 INCH DBL WALLED PIPE DIESEL 3/2 INCH DBL WALLED PIPE VAPOR RETURN 3 AND 2 INCH SINGLE WALL PIPE VAPOR VENT 2 INCH SINGLE WALLED PIPE PRODUCT SPILL CONTAINER VAPOR SPILL CONTAINER ANNULAR EMERGENCY SHUT-OFF OVERFILL ALARM FIRE EXTINGUISHER GAS METER SHUT-OFF HEALY CAS EVACUATION MEETING POINT CIRCUIT BREAKER UST ELECTRICAL PANEL AUTOMATIC TANK GAUGE AIR AND WATER DISPENSER HAZWASTE DRUM G A H P V SITE MAP PROJECT OWNER: JACO HILL PO. BOX 82515 BAKERSFIELD, CA 93308 CONTACT: SITE PLOT PLAN FOR: FACILITY 015-021-002928 CERS 10155965 FASTRIP #5562 1640 S CHESTER AVE. BAKERSFIELD, CA 93304 10/24/16 REV. C1 VICINITY MAP PROJECT DATA 1"=10'-0" INCHES012 SHEET SIZE 22 X 34 SCALE: 1640 S CHESTER AVE. BAKERSFIELD, CA 93304 S C H E S T E R A V E MING AVE Jaco #5562 Setup, and Alarm History before. Responses Received: 200 FASTRIP 562 MING-CHESTER BAKERSFIELD CA 661-397-8606 FEB 21, 2022 1:07 PM TANK PRODUCT GALLONS INCHES WATER DEG F ULLAGE 1 UNL 9971 73.96 0.0 59.4 2091 2 DIESEL 3081 29.06 0.0 64.5 8981 3 PNL 7576 57.73 0.0 62.3 4486 4 UNL 2 SIPHON 9282 69.01 0.0 57.8 2780 I90500 FEB 21, 2022 1:07 PM SOFTWARE REVISION LEVEL VERSION 329.01 SOFTWARE# 346329-100-B CREATED - 09.01.29.15.44 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD I50500 FEB 21, 2022 1:07 PM SYSTEM TYPE AND LANGUAGE FLAG SYSTEM UNITS U.S. SYSTEM LANGUAGE ENGLISH SYSTEM DATE/TIME FORMAT MON DD YYYY HH:MM:SS xM I50201 FEB 21, 2022 1:07 PM SHIFT TIME 1 : DISABLED I50202 FEB 21, 2022 1:07 PM SHIFT TIME 2 : DISABLED I50203 FEB 21, 2022 1:07 PM SHIFT TIME 3 : DISABLED I50204 FEB 21, 2022 1:07 PM SHIFT TIME 4 : DISABLED I54600 FEB 21, 2022 1:07 PM TANK PER TST NEEDED WRN: DISABLED I54900 FEB 21, 2022 1:07 PM TANK ANN TST NEEDED WRN: DISABLED I55300 FEB 21, 2022 1:07 PM LINE RE-ENABLE METHOD PASS LINE TEST I55600 FEB 21, 2022 1:07 PM LINE PER TST NEEDED WRN: DISABLED I55900 FEB 21, 2022 1:07 PM LINE ANN TST NEEDED WRN: DISABLED I50D00 FEB 21, 2022 1:07 PM PRINT TC VOLUMES ENABLED I50E00 FEB 21, 2022 1:07 PM TEMP COMPENSATION VALUE (DEG F ): 60.0 I60B00 FEB 21, 2022 1:07 PM STICK HEIGHT OFFSET ENABLE STATUS DISABLED I51400 FEB 21, 2022 1:07 PM H-PROTOCOL DATA FORMAT HEIGHT I51A01 FEB 21, 2022 1:07 PM DAYLIGHT SAVING TIME ENABLED OFF I51B00 FEB 21, 2022 1:08 PM DAYLIGHT SAVING TIME START DATE MAR WEEK 2 SUN 2:00 AM END DATE NOV WEEK 1 SUN 2:00 AM I51600 FEB 21, 2022 1:08 PM RE-DIRECT LOCAL PRINTOUT DISABLED I50400 FEB 21, 2022 1:08 PM 232 SECURITY CODE PORT SECURITY CODE STATUS 1 000000 DISABLED 2 000000 DISABLED 3 000000 DISABLED 4 000000 DISABLED 5 000000 DISABLED 6 000000 DISABLED I21900 FEB 21, 2022 1:08 PM TANK CHART SECURITY DISABLED I5BD00 FEB 21, 2022 1:08 PM CUSTOM ALARM LABELS DISABLED I56000 FEB 21, 2022 1:08 PM MASS/DENSITY DISABLED I88101 FEB 21, 2022 1:08 PM PORT SETTINGS: COMM BOARD : 1 (RS-232) BAUD RATE : 9600 PARITY : NONE STOP BIT : 1 STOP DATA LENGTH: 8 DATA RS-232 SECURITY CODE : DISABLED I88102 FEB 21, 2022 1:08 PM PORT SETTINGS: COMM BOARD : 2 (RS-232) BAUD RATE : 9600 PARITY : NONE STOP BIT : 1 STOP DATA LENGTH: 8 DATA RS-232 SECURITY CODE : DISABLED I88103 FEB 21, 2022 1:08 PM PORT SETTINGS: COMM BOARD : 3 (EDIM ) RS-232 SECURITY CODE : DISABLED I88104 FEB 21, 2022 1:08 PM I88105 FEB 21, 2022 1:08 PM I88106 FEB 21, 2022 1:08 PM I52000 FEB 21, 2022 1:08 PM RECEIVER AUTO DIAL TYPE & START TIME RCVR LOCATION LABEL DIAL TYPE START TIME 1 ON DATE FEB 28, 2020 DISABLED 2 ON DATE FEB 28, 2020 DISABLED 3 ON DATE FEB 28, 2020 DISABLED 4 ON DATE FEB 28, 2020 DISABLED 5 ON DATE FEB 28, 2020 DISABLED 6 ON DATE FEB 28, 2020 DISABLED 7 ON DATE FEB 28, 2020 DISABLED 8 ON DATE FEB 28, 2020 DISABLED I60100 FEB 21, 2022 1:08 PM TANK CONFIGURATION DEVICE LABEL CONFIGURED 1 UNL ON 2 DIESEL ON 3 PNL ON 4 UNL 2 SIPHON ON I60200 FEB 21, 2022 1:08 PM TANK PRODUCT LABEL TANK PRODUCT LABEL 1 UNL 2 DIESEL 3 PNL 4 UNL 2 SIPHON I60300 FEB 21, 2022 1:08 PM TANK PRODUCT CODE TANK PRODUCT LABEL 1 UNL 1 2 DIESEL 2 3 PNL 3 4 UNL 2 SIPHON 4 I60900 FEB 21, 2022 1:08 PM TANK THERMAL COEFFICIENT TANK PRODUCT LABEL 1 UNL 0.000700 2 DIESEL 0.000450 3 PNL 0.000700 4 UNL 2 SIPHON 0.000700 I60700 FEB 21, 2022 1:08 PM TANK DIAMETER TANK PRODUCT LABEL INCHES 1 UNL 96.00 2 DIESEL 96.00 3 PNL 96.00 4 UNL 2 SIPHON 96.00 I60A00 FEB 21, 2022 1:08 PM TANK FULL VOLUME TANK PRODUCT LABEL TANK PROFILE GALLONS 1 UNL 1 PT 12062 2 DIESEL 1 PT 12062 3 PNL 1 PT 12062 4 UNL 2 SIPHON 1 PT 12062 I60400 FEB 21, 2022 1:08 PM TANK FULL VOLUME TANK PRODUCT LABEL GALLONS 1 UNL 12062 2 DIESEL 12062 3 PNL 12062 4 UNL 2 SIPHON 12062 I60500 FEB 21, 2022 1:08 PM TANK 4 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 UNL 12062 0 0 0 2 DIESEL 12062 0 0 0 3 PNL 12062 0 0 0 4 UNL 2 SIPHON 12062 0 0 0 I60600 FEB 21, 2022 1:08 PM TANK 20 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 UNL 12062 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 DIESEL 12062 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3 PNL 12062 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4 UNL 2 SIPHON 12062 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 I61500 FEB 21, 2022 1:08 PM TANK PRODUCT LABEL METER DATA 1 UNL NO 2 DIESEL NO 3 PNL NO 4 UNL 2 SIPHON NO I62F00 FEB 21, 2022 1:08 PM MAG PROBE FLOAT SIZE TANK PRODUCT LABEL FLOAT SIZE: 1 UNL 4.0 INCHES 2 DIESEL 4.0 INCHES 3 PNL 3.0 INCHES 4 UNL 2 SIPHON 3.0 INCHES I62700 FEB 21, 2022 1:08 PM TANK HIGH WATER WARNING LIMIT TANK PRODUCT LABEL INCHES 1 UNL 2.0 2 DIESEL 2.0 3 PNL 2.0 4 UNL 2 SIPHON 2.0 9999FF1B I62400 FEB 21, 2022 1:08 PM TANK HIGH WATER LEVEL LIMIT TANK PRODUCT LABEL INCHES 1 UNL 3.0 2 DIESEL 3.0 3 PNL 3.0 4 UNL 2 SIPHON 3.0 I62800 FEB 21, 2022 1:08 PM TANK MAXIMUM VOLUME LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 12062 2 DIESEL 12062 3 PNL 12062 4 UNL 2 SIPHON 12062 I62300 FEB 21, 2022 1:08 PM TANK OVERFILL LEVEL LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 10855 2 DIESEL 10855 3 PNL 10855 4 UNL 2 SIPHON 10855 I62200 FEB 21, 2022 1:08 PM TANK HIGH PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 11459 2 DIESEL 11459 3 PNL 11459 4 UNL 2 SIPHON 11459 I62900 FEB 21, 2022 1:08 PM TANK DELIVERY REQUIRED LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 1809 2 DIESEL 1809 3 PNL 1809 4 UNL 2 SIPHON 1809 I62100 FEB 21, 2022 1:08 PM TANK LOW PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 500 2 DIESEL 500 3 PNL 500 4 UNL 2 SIPHON 500 I62600 FEB 21, 2022 1:08 PM TANK LEAK ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 99 2 DIESEL 99 3 PNL 99 4 UNL 2 SIPHON 99 I62500 FEB 21, 2022 1:08 PM TANK SUDDEN LOSS LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 99 2 DIESEL 99 3 PNL 99 4 UNL 2 SIPHON 99 I60800 FEB 21, 2022 1:08 PM TANK TILT TANK PRODUCT LABEL INCHES 1 UNL 4.50 2 DIESEL -3.00 3 PNL 4.30 4 UNL 2 SIPHON 4.44 I60B00 FEB 21, 2022 1:08 PM STICK HEIGHT OFFSET ENABLE STATUS DISABLED I60C00 FEB 21, 2022 1:08 PM TANK STICK HEIGHT OFFSET TANK PRODUCT LABEL INCHES 1 UNL 0.00 2 DIESEL 0.00 3 PNL 0.00 4 UNL 2 SIPHON 0.00 I61200 FEB 21, 2022 1:08 PM TANK MANIFOLDED PARTNERS TANK PRODUCT LABEL SIPHON MANIFOLDED TANKS LINE MANIFOLDED TANKS 1 UNL NONE NONE 2 DIESEL NONE NONE 3 PNL NONE NONE 4 UNL 2 SIPHON NONE NONE I63600 FEB 21, 2022 1:08 PM PERIODIC LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 UNL 1220 2 DIESEL 120 3 PNL 120 4 UNL 2 SIPHON 120 I62A00 FEB 21, 2022 1:08 PM ANNUAL LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 UNL 0 2 DIESEL 0 3 PNL 0 4 UNL 2 SIPHON 120 I62C00 FEB 21, 2022 1:08 PM TANK PERIODIC TEST TYPE TANK PRODUCT LABEL PERIODIC TEST TYPE 1 UNL STANDARD 2 DIESEL STANDARD 3 PNL STANDARD 4 UNL 2 SIPHON STANDARD I62D00 FEB 21, 2022 1:08 PM TANK LEAK TEST FAIL ALARMS TANK PRODUCT LABEL 1 UNL GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED 2 DIESEL GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 3 PNL GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 4 UNL 2 SIPHON GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED I63100 FEB 21, 2022 1:08 PM TANK LEAK TEST AVERAGING TANK PRODUCT LABEL ANNUAL PERIODIC 1 UNL OFF OFF 2 DIESEL OFF OFF 3 PNL OFF OFF 4 UNL 2 SIPHON OFF OFF I63000 FEB 21, 2022 1:08 PM IN-TANK LEAK TEST NOTIFY TANK PRODUCT LABEL TANK TEST NOTIFY: 1 UNL OFF 2 DIESEL OFF 3 PNL OFF 4 UNL 2 SIPHON OFF I63200 FEB 21, 2022 1:08 PM TANK TEST SIPHON BREAK TANK PRODUCT LABEL SIPHON BREAK 1 UNL OFF 2 DIESEL OFF 3 PNL OFF 4 UNL 2 SIPHON OFF I61000 FEB 21, 2022 1:08 PM TANK DELIVERY DELAY TANK PRODUCT LABEL 1 UNL 1 2 DIESEL 1 3 PNL 1 4 UNL 2 SIPHON 1 I63A00 FEB 21, 2022 1:08 PM LOW LEVEL PUMP THRESHOLD FOR SEQUENTIAL LINE MANIFOLD TANK PRODUCT LABEL PUMP THRESHOLD 1 UNL 10.00% 2 DIESEL 10.00% 3 PNL 10.00% 4 UNL 2 SIPHON 10.00% I61100 FEB 21, 2022 1:08 PM LEAK TEST METHOD - - - - - - - - - - - - TEST ON DATE : TANK 1 MAR 19, 2009 START TIME : DISABLED TEST RATE :0.20 GAL/HR DURATION : 2 HOURS TST EARLY STOP:DISABLED TEST ON DATE : TANK 2 MAR 19, 2009 START TIME : DISABLED TEST RATE :0.20 GAL/HR DURATION : 2 HOURS TST EARLY STOP:DISABLED TEST ON DATE : TANK 3 MAR 19, 2009 START TIME : DISABLED TEST RATE :0.20 GAL/HR DURATION : 2 HOURS TST EARLY STOP:DISABLED TEST ON DATE : TANK 4 MAR 19, 2009 START TIME : DISABLED TEST RATE :0.20 GAL/HR DURATION : 2 HOURS TST EARLY STOP:DISABLED I61300 FEB 21, 2022 1:08 PM CSLD PROBABLITY OF DETECTION I61400 FEB 21, 2022 1:08 PM CSLD CLIMATE FACTOR I61600 FEB 21, 2022 1:08 PM TANK PRODUCT LABEL CAL UPDATE 1 UNL IMMEDIATE 2 DIESEL IMMEDIATE 3 PNL IMMEDIATE 4 UNL 2 SIPHON IMMEDIATE I61A00 FEB 21, 2022 1:08 PM IN-TANK LEAK TEST EARLY STOP TANK PRODUCT LABEL TST EARLY STOP: 1 UNL DISABLED 2 DIESEL DISABLED 3 PNL DISABLED 4 UNL 2 SIPHON DISABLED I61B00 FEB 21, 2022 1:08 PM IN-TANK LEAK GROSS TEST AUTO-CONFIRM I61C00 FEB 21, 2022 1:08 PM CSLD REPORT ONLY I62B00 FEB 21, 2022 1:08 PM TANK LAST ANNUAL TEST TANK PRODUCT LABEL DATE 1 UNL ??? 0, 0 2 DIESEL ??? 0, 0 3 PNL ??? 0, 0 4 UNL 2 SIPHON ??? 0, 0 I63300 FEB 21, 2022 1:08 PM LEAK TEST REPORT FORMAT: NORMAL I63400 FEB 21, 2022 1:08 PM RECONCILIATION WARNING LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 0 2 DIESEL 0 3 PNL 0 4 UNL 2 SIPHON 0 I63500 FEB 21, 2022 1:08 PM RECONCILIATION ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 1 2 DIESEL 1 3 PNL 1 4 UNL 2 SIPHON 1 I63900 FEB 21, 2022 1:08 PM ACCU CHART END SHAPE FACTOR TANK PRODUCT LABEL 1 UNL END FACTOR: NONE 2 DIESEL END FACTOR: NONE 3 PNL END FACTOR: NONE 4 UNL 2 SIPHON END FACTOR: NONE I78000 FEB 21, 2022 1:08 PM I77700 FEB 21, 2022 1:08 PM I77800 FEB 21, 2022 1:08 PM I78C00 FEB 21, 2022 1:08 PM I78300 FEB 21, 2022 1:08 PM I78F00 FEB 21, 2022 1:08 PM I78700 FEB 21, 2022 1:08 PM I70200 FEB 21, 2022 1:08 PM LIQUID LABEL DEVICE LABEL 1 UNL 1 STP 2 UNL1 ANN 3 DIESEL STP 4 DIESEL ANN 5 PNL STP 6 PNL ANN 7 UNL2 SIPON STP 8 UNL2 ANN 9 DISP 1-2 10 DISP 3-4 11 DISP 5-6 12 DISP 7-8 13 TRAN NO. 14 TRAN SO. 15 16 I70300 FEB 21, 2022 1:08 PM LIQUID TYPE SENSOR LOCATION TYPE 1 UNL 1 STP TRI-STATE (SINGLE FLOAT) 2 UNL1 ANN TRI-STATE (SINGLE FLOAT) 3 DIESEL STP TRI-STATE (SINGLE FLOAT) 4 DIESEL ANN TRI-STATE (SINGLE FLOAT) 5 PNL STP TRI-STATE (SINGLE FLOAT) 6 PNL ANN TRI-STATE (SINGLE FLOAT) 7 UNL2 SIPON STP TRI-STATE (SINGLE FLOAT) 8 UNL2 ANN TRI-STATE (SINGLE FLOAT) 9 DISP 1-2 TRI-STATE (SINGLE FLOAT) 10 DISP 3-4 TRI-STATE (SINGLE FLOAT) 11 DISP 5-6 TRI-STATE (SINGLE FLOAT) 12 DISP 7-8 TRI-STATE (SINGLE FLOAT) 13 TRAN NO. TRI-STATE (SINGLE FLOAT) 14 TRAN SO. TRI-STATE (SINGLE FLOAT) 15 TRI-STATE (SINGLE FLOAT) 16 TRI-STATE (SINGLE FLOAT) I70400 FEB 21, 2022 1:08 PM LIQUID CATEGORY SENSOR LOCATION CATEGORY 1 UNL 1 STP STP SUMP 2 UNL1 ANN ANNULAR SPACE 3 DIESEL STP STP SUMP 4 DIESEL ANN ANNULAR SPACE 5 PNL STP STP SUMP 6 PNL ANN ANNULAR SPACE 7 UNL2 SIPON STP STP SUMP 8 UNL2 ANN ANNULAR SPACE 9 DISP 1-2 DISPENSER PAN 10 DISP 3-4 DISPENSER PAN 11 DISP 5-6 DISPENSER PAN 12 DISP 7-8 DISPENSER PAN 13 TRAN NO. PIPING SUMP 14 TRAN SO. PIPING SUMP 15 OTHER SENSORS 16 OTHER SENSORS I74200 FEB 21, 2022 1:08 PM I74300 FEB 21, 2022 1:08 PM I74400 FEB 21, 2022 1:08 PM I74700 FEB 21, 2022 1:08 PM I74800 FEB 21, 2022 1:08 PM I74900 FEB 21, 2022 1:08 PM I7BC00 FEB 21, 2022 1:08 PM I80200 FEB 21, 2022 1:08 PM I80300 FEB 21, 2022 1:08 PM I80400 FEB 21, 2022 1:08 PM I80700 FEB 21, 2022 1:08 PM RELAY LABEL DEVICE LABEL 1 UNL 1 2 DIESEL 3 PNL 4 5 OVERFILL ALARM 6 7 8 I80900 FEB 21, 2022 1:08 PM RELAY ORIENTATION RELAY DESIGNATION ORIENTATION 1 UNL 1 NORMALLY OPEN 2 DIESEL NORMALLY CLOSED 3 PNL NORMALLY OPEN 4 NORMALLY OPEN 5 OVERFILL ALARM NORMALLY OPEN 6 NORMALLY OPEN 7 NORMALLY OPEN 8 NORMALLY OPEN I80B00 FEB 21, 2022 1:08 PM RELAY TANK ASSIGNMENT RELAY DESIGNATION TANK 1 UNL 1 1 2 DIESEL 2 3 PNL 3 4 NONE 5 OVERFILL ALARM NONE 6 NONE 7 NONE 8 NONE I80A00 FEB 21, 2022 1:08 PM RELAY TYPE RELAY DESIGNATION TYPE 1 UNL 1 PUMP CONTROL OUTPUT 2 DIESEL STANDARD 3 PNL PUMP CONTROL OUTPUT 4 STANDARD 5 OVERFILL ALARM STANDARD 6 STANDARD 7 STANDARD 8 STANDARD I80C00 FEB 21, 2022 1:08 PM I80800 FEB 21, 2022 1:08 PM RELAY SETUP REPORT R 1:UNL 1 TYPE: PUMP CONTROL OUTPUT TANK #: 1 LIQUID SENSOR ALMS L 1:FUEL ALARM L 7:FUEL ALARM L 9:FUEL ALARM L10:FUEL ALARM L11:FUEL ALARM L12:FUEL ALARM L 1:SENSOR OUT ALARM L 7:SENSOR OUT ALARM L 9:SENSOR OUT ALARM L10:SENSOR OUT ALARM L11:SENSOR OUT ALARM L12:SENSOR OUT ALARM L 1:SHORT ALARM L 7:SHORT ALARM L 9:SHORT ALARM L10:SHORT ALARM L11:SHORT ALARM L12:SHORT ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD VP PRES FAIL ISD VP STATUS FAIL ISD HOSE ALARMS ALL:GROSS COLLECT FAIL ALL:DEGRD COLLECT FAIL ALL:FLOW COLLECT FAIL R 2:DIESEL TYPE: STANDARD NORMALLY CLOSED TANK #: 2 LIQUID SENSOR ALMS L 3:FUEL ALARM L 9:FUEL ALARM L11:FUEL ALARM L13:FUEL ALARM L14:FUEL ALARM L 3:SENSOR OUT ALARM L 9:SENSOR OUT ALARM L11:SENSOR OUT ALARM L13:SENSOR OUT ALARM L14:SENSOR OUT ALARM L 3:SHORT ALARM L 4:SHORT ALARM L 9:SHORT ALARM L11:SHORT ALARM L13:SHORT ALARM L14:SHORT ALARM R 3:PNL TYPE: PUMP CONTROL OUTPUT TANK #: 3 LIQUID SENSOR ALMS L 5:FUEL ALARM L 9:FUEL ALARM L10:FUEL ALARM L11:FUEL ALARM L12:FUEL ALARM L 5:SENSOR OUT ALARM L 9:SENSOR OUT ALARM L10:SENSOR OUT ALARM L11:SENSOR OUT ALARM L12:SENSOR OUT ALARM ISD HOSE ALARMS ALL:GROSS COLLECT FAIL ALL:DEGRD COLLECT FAIL ALL:FLOW COLLECT FAIL R 4: TYPE: STANDARD NORMALLY OPEN TANK #: NONE - NO ALARM ASSIGNMENTS - R 5:OVERFILL ALARM TYPE: STANDARD NORMALLY OPEN TANK #: NONE IN-TANK ALARMS ALL:OVERFILL ALARM ALL:HIGH PRODUCT ALARM ALL:MAX PRODUCT ALARM R 6: TYPE: STANDARD NORMALLY OPEN TANK #: NONE - NO ALARM ASSIGNMENTS - R 7: TYPE: STANDARD NORMALLY OPEN TANK #: NONE - NO ALARM ASSIGNMENTS - R 8: TYPE: STANDARD NORMALLY OPEN TANK #: NONE - NO ALARM ASSIGNMENTS - I79000 FEB 21, 2022 1:09 PM EDIM:1 VR:349634-003-C TD:06.05.11.11.15 I79100 FEB 21, 2022 1:09 PM I72300 FEB 21, 2022 1:09 PM FASTRIP 562 MING-CHESTER BAKERSFIELD CA 661-397-8606 SMARTSENSOR ASSIGNMENT DEVICE LABEL CATEGORY 01 V.P.SENSOR DISP 3-4 VAPOR PRESSURE 02 F.M.DISP 1-2 AIR FLOW METER 03 F.M.DISP 3-4 AIR FLOW METER 04 F.M.DISP 5-6 AIR FLOW METER 05 F.M.DISP 7-8 AIR FLOW METER 06 UNKNOWN 07 UNKNOWN 08 UNKNOWN 09 UNKNOWN 10 UNKNOWN 11 UNKNOWN 12 UNKNOWN 13 UNKNOWN 14 UNKNOWN 15 UNKNOWN 16 UNKNOWN 17 UNKNOWN 18 UNKNOWN 19 UNKNOWN 20 UNKNOWN 21 UNKNOWN 22 UNKNOWN 23 UNKNOWN 24 UNKNOWN 25 UNKNOWN 26 UNKNOWN 27 UNKNOWN 28 UNKNOWN 29 UNKNOWN 30 UNKNOWN 31 UNKNOWN 32 UNKNOWN 33 UNKNOWN 34 UNKNOWN 35 UNKNOWN 36 UNKNOWN 37 UNKNOWN 38 UNKNOWN 39 UNKNOWN 40 UNKNOWN IV4E00 FEB 21, 2022 1:09 PM FASTRIP 562 MING-CHESTER BAKERSFIELD CA 661-397-8606 EVR/ISD SETUP TYPE: VACUUM ASSIST VACUUM ASSIST TYPE: HEALY VAC IV4F00 FEB 21, 2022 1:09 PM FASTRIP 562 MING-CHESTER BAKERSFIELD CA 661-397-8606 NOZZLE A/L RANGE A/L RATIO: 0.95 - 1.15 IV4000 FEB 21, 2022 1:09 PM FASTRIP 562 MING-CHESTER BAKERSFIELD CA 661-397-8606 VAPOR PROCESSOR TYPE NONE IV4700 FEB 21, 2022 1:09 PM FASTRIP 562 MING-CHESTER BAKERSFIELD CA 661-397-8606 ASSESSMENT TIME START TIME: 10:00 AM TIME DELAY MINUTES: 1 IV5200 FEB 21, 2022 1:09 PM FASTRIP 562 MING-CHESTER BAKERSFIELD CA 661-397-8606 ACCEPT HIGH ORVR: YES IV4A00 FEB 21, 2022 1:09 PM FASTRIP 562 MING-CHESTER BAKERSFIELD CA 661-397-8606 ISD HOSE TABLE HOSE FP FP AFM HOSE ID ID LABEL ID LABEL 01 01 01 01 BLEND3 02 02 02 01 BLEND3 03 03 03 02 BLEND3 04 04 04 02 BLEND3 05 05 05 03 BLEND3 06 06 06 03 BLEND3 07 07 07 04 BLEND3 08 08 08 04 BLEND3 IV4B00 FEB 21, 2022 1:09 PM FASTRIP 562 MING-CHESTER BAKERSFIELD CA 661-397-8606 PRODUCT/HOSE MAP TABLE FP AFID M1/H1 M2/H2 M3/H3 M4/H4 01 01 02/01 03/01 09/01 xx/xx 02 01 02/02 03/02 09/02 xx/xx 03 02 02/03 03/03 09/03 xx/xx 04 02 02/04 03/04 09/04 xx/xx 05 03 02/05 03/05 09/05 xx/xx 06 03 02/06 03/06 09/06 xx/xx 07 04 02/07 03/07 09/07 xx/xx 08 04 02/08 03/08 09/08 xx/xx IV4900 FEB 21, 2022 1:09 PM FASTRIP 562 MING-CHESTER BAKERSFIELD CA 661-397-8606 LABEL TABLE ID LABEL 01 UNASSIGNED 02 BLEND3 03 REGULAR 04 MID GRADE 05 PREMIUM 06 GOLD 07 BRONZE 08 SILVER 09 BLEND2 10 BLEND4 IV1000 FEB 21, 2022 1:09 PM ISD VERSION: 01.02 Alarm History Before. Responses Received: I10200 FEB 21, 2022 1:10 PM FASTRIP 562 MING-CHESTER BAKERSFIELD CA 661-397-8606 SYSTEM CONFIGURATION SLOT BOARD TYPE POWER ON RESET CURRENT 1 7SMARTSENSOR BD 508079 516932 2 4 PROBE / G.T. 161504 162478 3 INTERSTITIAL BD 202172 203570 4 INTERSTITIAL BD 202533 203780 5 UNUSED 4812041 4949442 6 UNUSED 4809760 4940841 7 UNUSED 4811310 4940152 8 UNUSED 4810181 4939099 9 STP SENSE BOARD 33224 33371 10 RELAY BOARD 14888 14935 11 RELAY BOARD 14955 15043 12 UNUSED 4813085 4939927 13 UNUSED 4809830 4938723 14 UNUSED 4811668 4934143 15 UNUSED 4807351 4933326 16 UNUSED 4811447 4934508 COMM 1 RS232 SERIAL BD 14932 14913 COMM 2 RS232 SERIAL BD 14977 15000 COMM 3 ELEC DISP INT. 101186 101622 COMM 4 UNUSED 4810118 4934358 COMM 5 UNUSED 4811956 4930767 COMM 6 UNUSED 4806399 4932659 I90200 FEB 21, 2022 1:10 PM SOFTWARE REVISION LEVEL VERSION 329.01 SOFTWARE# 346329-100-B CREATED - 09.01.29.15.44 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD I11100 FEB 21, 2022 1:10 PM FASTRIP 562 MING-CHESTER BAKERSFIELD CA 661-397-8606 PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME h 8 OTHER FP8: BLEND3 GROSS COLLECT FAIL ALARM 2-21-22 10:01AM h 8 OTHER FP8: BLEND3 GROSS COLLECT FAIL CLEAR 2-21-22 10:01AM h 2 OTHER FP2: BLEND3 GROSS COLLECT FAIL ALARM 2-21-22 10:01AM h 2 OTHER FP2: BLEND3 GROSS COLLECT FAIL CLEAR 2-21-22 10:01AM h 8 OTHER FP8: BLEND3 GROSS COLLECT FAIL ALARM 2-20-22 10:01AM h 8 OTHER FP8: BLEND3 GROSS COLLECT FAIL CLEAR 2-20-22 10:01AM h 2 OTHER FP2: BLEND3 GROSS COLLECT FAIL ALARM 2-20-22 10:01AM h 2 OTHER FP2: BLEND3 GROSS COLLECT FAIL CLEAR 2-20-22 10:01AM T 1 TANK UNL OVERFILL ALARM CLEAR 2-20-22 12:33AM T 1 TANK UNL OVERFILL ALARM ALARM 2-20-22 12:30AM h 8 OTHER FP8: BLEND3 GROSS COLLECT FAIL ALARM 2-19-22 10:01AM h 2 OTHER FP2: BLEND3 GROSS COLLECT FAIL ALARM 2-19-22 10:01AM h 2 OTHER FP2: BLEND3 GROSS COLLECT FAIL CLEAR 2-16-22 10:00AM h 2 OTHER FP2: BLEND3 GROSS COLLECT FAIL ALARM 2-15-22 10:01AM T 1 TANK UNL OVERFILL ALARM CLEAR 2-14-22 2:02AM T 1 TANK UNL OVERFILL ALARM ALARM 2-14-22 1:59AM OTHER ISD GROSS PRES FAIL CLEAR 1-30-22 12:19PM OTHER ISD GROSS PRES FAIL ALARM 1-30-22 11:49AM OTHER ISD GROSS PRES FAIL CLEAR 12-30-21 8:35AM L 4 ANNULAR DIESEL ANN FUEL ALARM CLEAR 12-29-21 1:19PM L 4 ANNULAR DIESEL ANN FUEL ALARM ALARM 12-29-21 1:19PM L 4 ANNULAR DIESEL ANN FUEL ALARM CLEAR 12-29-21 1:02PM L 4 ANNULAR DIESEL ANN FUEL ALARM ALARM 12-29-21 1:02PM L 4 ANNULAR DIESEL ANN FUEL ALARM CLEAR 12-29-21 12:58PM L 4 ANNULAR DIESEL ANN FUEL ALARM ALARM 12-29-21 12:57PM L 4 ANNULAR DIESEL ANN FUEL ALARM CLEAR 12-29-21 12:54PM OTHER ISD GROSS PRES FAIL ALARM 12-29-21 11:49AM L 4 ANNULAR DIESEL ANN FUEL ALARM ALARM 12-28-21 1:05AM T 1 TANK UNL OVERFILL ALARM CLEAR 12-26-21 7:33AM T 1 TANK UNL OVERFILL ALARM ALARM 12-26-21 7:30AM L 3 STP SUMP DIESEL STP FUEL ALARM CLEAR 12-25-21 3:26AM L 3 STP SUMP DIESEL STP FUEL ALARM ALARM 12-24-21 6:33PM L 4 ANNULAR DIESEL ANN FUEL ALARM CLEAR 12-23-21 2:43PM L 4 ANNULAR DIESEL ANN FUEL ALARM ALARM 12-23-21 2:42PM L 4 ANNULAR DIESEL ANN FUEL ALARM CLEAR 12-23-21 2:38PM L 4 ANNULAR DIESEL ANN FUEL ALARM ALARM 12-23-21 11:52AM T 1 TANK UNL OVERFILL ALARM CLEAR 12-10-21 12:47AM T 1 TANK UNL OVERFILL ALARM ALARM 12-10-21 12:42AM L 3 STP SUMP DIESEL STP FUEL ALARM CLEAR 11-19-21 10:06AM L 3 STP SUMP DIESEL STP FUEL ALARM ALARM 11-19-21 3:44AM T 3 TANK PNL OVERFILL ALARM CLEAR 11-17-21 3:44PM T 3 TANK PNL OVERFILL ALARM ALARM 11-17-21 3:42PM L 7 STP SUMP UNL2 SIPON STP FUEL ALARM CLEAR 10-25-21 9:04PM L 7 STP SUMP UNL2 SIPON STP FUEL ALARM ALARM 10-25-21 5:20PM L 3 STP SUMP DIESEL STP FUEL ALARM CLEAR 10-25-21 3:44PM L 3 STP SUMP DIESEL STP FUEL ALARM ALARM 10-25-21 1:43PM T 1 TANK UNL OVERFILL ALARM CLEAR 10-13-21 1:59AM T 1 TANK UNL OVERFILL ALARM ALARM 10-13-21 1:57AM T 1 TANK UNL OVERFILL ALARM CLEAR 10-02-21 7:21PM T 1 TANK UNL OVERFILL ALARM ALARM 10-02-21 7:17PM I11200 FEB 21, 2022 1:10 PM FASTRIP 562 MING-CHESTER BAKERSFIELD CA 661-397-8606 NON-PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME OTHER ISD GROSS PRES WARN ALARM 2-21-22 10:01AM h 4 OTHER FP4: BLEND3 GROSS COLLECT WARN CLEAR 2-21-22 10:00AM h 4 OTHER FP4: BLEND3 GROSS COLLECT WARN ALARM 2-20-22 10:01AM h 8 OTHER FP8: BLEND3 GROSS COLLECT WARN CLEAR 2-19-22 10:00AM h 2 OTHER FP2: BLEND3 GROSS COLLECT WARN CLEAR 2-19-22 10:00AM T 2 TANK DIESEL DELIVERY NEEDED CLEAR 2-19-22 3:13AM h 8 OTHER FP8: BLEND3 GROSS COLLECT WARN ALARM 2-18-22 10:01AM h 2 OTHER FP2: BLEND3 GROSS COLLECT WARN ALARM 2-18-22 10:01AM T 2 TANK DIESEL DELIVERY NEEDED ALARM 2-17-22 8:42PM h 8 OTHER FP8: BLEND3 GROSS COLLECT WARN CLEAR 2-17-22 9:49AM h 8 OTHER FP8: BLEND3 GROSS COLLECT WARN ALARM 2-16-22 10:01AM h 6 OTHER FP6: BLEND3 DEGRD COLLECT WARN CLEAR 2-16-22 10:00AM h 2 OTHER FP2: BLEND3 GROSS COLLECT WARN CLEAR 2-15-22 10:00AM OTHER ISD GROSS PRES WARN CLEAR 2-14-22 12:25PM OTHER ISD GROSS PRES WARN ALARM 2-14-22 10:01AM h 2 OTHER FP2: BLEND3 GROSS COLLECT WARN ALARM 2-14-22 10:01AM h 6 OTHER FP6: BLEND3 DEGRD COLLECT WARN ALARM 2-13-22 10:01AM h 2 OTHER FP2: BLEND3 GROSS COLLECT WARN CLEAR 2-11-22 6:13PM h 2 OTHER FP2: BLEND3 GROSS COLLECT WARN ALARM 2-11-22 10:01AM h 4 OTHER FP4: BLEND3 DEGRD COLLECT WARN CLEAR 2-10-22 10:00AM h 4 OTHER FP4: BLEND3 DEGRD COLLECT WARN ALARM 2-09-22 10:01AM h 2 OTHER FP2: BLEND3 GROSS COLLECT WARN CLEAR 2-08-22 9:51AM h 2 OTHER FP2: BLEND3 GROSS COLLECT WARN ALARM 2-07-22 10:01AM OTHER ISD GROSS PRES WARN CLEAR 2-06-22 10:32AM OTHER ISD GROSS PRES WARN ALARM 2-06-22 10:01AM h 6 OTHER FP6: BLEND3 GROSS COLLECT WARN CLEAR 2-06-22 9:59AM T 2 TANK DIESEL DELIVERY NEEDED CLEAR 2-05-22 4:14PM h 6 OTHER FP6: BLEND3 GROSS COLLECT WARN ALARM 2-05-22 10:01AM T 2 TANK DIESEL DELIVERY NEEDED ALARM 2-05-22 7:28AM h 4 OTHER FP4: BLEND3 GROSS COLLECT WARN CLEAR 2-03-22 10:16AM h 6 OTHER FP6: BLEND3 GROSS COLLECT WARN CLEAR 2-03-22 10:16AM SYSTEM PRINTER ERROR CLEAR 2-03-22 10:12AM SYSTEM PAPER OUT CLEAR 2-03-22 10:12AM SYSTEM PRINTER ERROR ALARM 2-03-22 10:10AM SYSTEM PAPER OUT ALARM 2-03-22 10:10AM SYSTEM PRINTER ERROR CLEAR 2-03-22 9:25AM SYSTEM PRINTER ERROR ALARM 2-03-22 9:25AM h 6 OTHER FP6: BLEND3 GROSS COLLECT WARN ALARM 2-02-22 11:49AM h 4 OTHER FP4: BLEND3 GROSS COLLECT WARN ALARM 2-02-22 11:49AM OTHER ISD GROSS PRES WARN CLEAR 1-30-22 11:48AM OTHER ISD GROSS PRES WARN ALARM 1-23-22 11:49AM T 4 TANK UNL 2 SIPHON DELIVERY NEEDED CLEAR 1-21-22 2:27AM T 4 TANK UNL 2 SIPHON DELIVERY NEEDED ALARM 1-20-22 9:53PM OTHER ISD GROSS PRES WARN CLEAR 1-17-22 7:50AM OTHER ISD GROSS PRES WARN ALARM 1-14-22 11:49AM SYSTEM PRINTER ERROR CLEAR 12-29-21 12:52PM SYSTEM PAPER OUT CLEAR 12-29-21 12:52PM SYSTEM PRINTER ERROR ALARM 12-29-21 12:48PM SYSTEM PAPER OUT ALARM 12-29-21 12:48PM OTHER ISD GROSS PRES WARN CLEAR 12-29-21 11:48AM I20600 FEB 21, 2022 1:10 PM FASTRIP 562 MING-CHESTER BAKERSFIELD CA 661-397-8606 TANK ALARM HISTORY TANK 1 UNL SETUP DATA WARNING JAN 29, 2009 8:13 AM OVERFILL ALARM FEB 20, 2022 12:30 AM FEB 14, 2022 1:59 AM DEC 26, 2021 7:30 AM SUDDEN LOSS ALARM JUL 25, 2021 3:26 AM JUL 25, 2021 2:38 AM JUL 25, 2021 2:06 AM HIGH PRODUCT ALARM SEP 8, 2020 11:51 AM JUL 9, 2019 5:06 PM MAY 12, 2019 6:37 AM PROBE OUT SEP 8, 2020 11:52 AM SEP 8, 2020 11:50 AM NOV 28, 2018 12:07 PM DELIVERY NEEDED APR 27, 2020 10:41 AM LOW TEMP WARNING SEP 8, 2020 11:53 AM NOV 28, 2018 12:07 PM TANK 2 DIESEL HIGH WATER ALARM SEP 1, 2020 12:00 PM OVERFILL ALARM SEP 8, 2020 11:32 AM SEP 1, 2020 12:19 PM NOV 28, 2018 11:54 AM LOW PRODUCT ALARM SEP 8, 2020 11:33 AM SEP 1, 2020 11:53 AM INVALID FUEL LEVEL SEP 8, 2020 11:33 AM SEP 8, 2020 11:31 AM SEP 2, 2020 9:16 AM PROBE OUT SEP 8, 2020 11:33 AM SEP 8, 2020 11:30 AM SEP 1, 2020 5:21 PM HIGH WATER WARNING SEP 1, 2020 12:00 PM DELIVERY NEEDED FEB 17, 2022 8:42 PM FEB 5, 2022 7:28 AM AUG 14, 2021 11:50 AM LOW TEMP WARNING NOV 28, 2018 11:56 AM TANK 3 PNL HIGH WATER ALARM SEP 1, 2020 5:26 PM OVERFILL ALARM NOV 17, 2021 3:42 PM SEP 8, 2020 11:28 AM SEP 1, 2020 12:33 PM SUDDEN LOSS ALARM SEP 8, 2020 11:26 AM SEP 8, 2020 10:43 AM SEP 1, 2020 11:50 AM HIGH PRODUCT ALARM SEP 8, 2020 11:28 AM SEP 1, 2020 5:27 PM SEP 1, 2020 5:23 PM INVALID FUEL LEVEL SEP 8, 2020 11:29 AM SEP 1, 2020 5:35 PM MAR 5, 2020 12:03 PM PROBE OUT SEP 8, 2020 11:28 AM SEP 8, 2020 11:26 AM SEP 1, 2020 5:38 PM HIGH WATER WARNING SEP 1, 2020 5:26 PM DELIVERY NEEDED SEP 8, 2020 11:29 AM SEP 8, 2020 11:27 AM SEP 8, 2020 10:43 AM MAX PRODUCT ALARM SEP 1, 2020 5:27 PM SEP 1, 2020 5:23 PM LOW TEMP WARNING SEP 1, 2020 5:39 PM NOV 28, 2018 11:59 AM SEP 10, 2018 10:05 AM TANK 4 UNL 2 SIPHON OVERFILL ALARM SEP 8, 2021 9:20 PM NOV 27, 2020 11:57 AM SEP 8, 2020 11:56 AM HIGH PRODUCT ALARM SEP 8, 2020 11:56 AM PROBE OUT SEP 8, 2020 11:57 AM SEP 8, 2020 11:54 AM JAN 22, 2019 11:39 AM DELIVERY NEEDED JAN 20, 2022 9:53 PM APR 18, 2021 10:24 PM JAN 17, 2019 2:31 PM LOW TEMP WARNING NOV 28, 2018 12:14 PM I38200 FEB 21, 2022 1:10 PM I30200 FEB 21, 2022 1:10 PM FASTRIP 562 MING-CHESTER BAKERSFIELD CA 661-397-8606 LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 UNL 1 STP SEP 28, 2021 10:14 AM SENSOR OUT ALARM SEP 28, 2021 9:56 AM FUEL ALARM SEP 28, 2021 9:54 AM FUEL ALARM 2 UNL1 ANN SEP 28, 2021 10:14 AM SENSOR OUT ALARM SEP 28, 2021 9:39 AM FUEL ALARM SEP 13, 2021 2:13 PM SENSOR OUT ALARM 3 DIESEL STP DEC 24, 2021 6:33 PM FUEL ALARM NOV 19, 2021 3:44 AM FUEL ALARM OCT 25, 2021 1:43 PM FUEL ALARM 4 DIESEL ANN DEC 29, 2021 1:19 PM FUEL ALARM DEC 29, 2021 1:02 PM FUEL ALARM DEC 29, 2021 12:57 PM FUEL ALARM 5 PNL STP SEP 28, 2021 10:14 AM SENSOR OUT ALARM SEP 28, 2021 9:33 AM FUEL ALARM SEP 13, 2021 2:13 PM SENSOR OUT ALARM 6 PNL ANN SEP 28, 2021 10:14 AM SENSOR OUT ALARM SEP 28, 2021 9:41 AM FUEL ALARM SEP 13, 2021 2:13 PM SENSOR OUT ALARM 7 UNL2 SIPON STP OCT 25, 2021 5:20 PM FUEL ALARM SEP 28, 2021 10:14 AM SENSOR OUT ALARM SEP 28, 2021 9:57 AM FUEL ALARM 8 UNL2 ANN SEP 28, 2021 10:14 AM SENSOR OUT ALARM SEP 28, 2021 9:38 AM FUEL ALARM SEP 13, 2021 2:13 PM SENSOR OUT ALARM 9 DISP 1-2 SEP 28, 2021 10:14 AM SENSOR OUT ALARM SEP 28, 2021 10:03 AM FUEL ALARM SEP 28, 2021 9:55 AM FUEL ALARM 10 DISP 3-4 SEP 28, 2021 10:14 AM SENSOR OUT ALARM SEP 28, 2021 10:02 AM FUEL ALARM SEP 13, 2021 2:13 PM SENSOR OUT ALARM 11 DISP 5-6 SEP 28, 2021 10:14 AM SENSOR OUT ALARM SEP 28, 2021 10:05 AM FUEL ALARM SEP 13, 2021 2:13 PM SENSOR OUT ALARM 12 DISP 7-8 SEP 28, 2021 10:14 AM SENSOR OUT ALARM SEP 28, 2021 9:56 AM FUEL ALARM SEP 28, 2021 9:47 AM FUEL ALARM 13 TRAN NO. SEP 28, 2021 10:14 AM SENSOR OUT ALARM SEP 28, 2021 10:03 AM FUEL ALARM SEP 13, 2021 2:12 PM SENSOR OUT ALARM 14 TRAN SO. SEP 28, 2021 10:14 AM SENSOR OUT ALARM SEP 28, 2021 10:05 AM FUEL ALARM SEP 13, 2021 2:13 PM SENSOR OUT ALARM I31600 FEB 21, 2022 1:10 PM FASTRIP 562 MING-CHESTER BAKERSFIELD CA 661-397-8606 SMART SENSOR ALARM HISTORY REPORT SENSOR LOCATION 1 V.P.SENSOR DISP 3-4 2 F.M.DISP 1-2 3 F.M.DISP 3-4 4 F.M.DISP 5-6 5 F.M.DISP 7-8 FEB 22, 2020 8:22 AM COMMUNICATION ALARM FEB 16, 2020 8:41 AM COMMUNICATION ALARM DEC 22, 2019 3:33 PM COMMUNICATION ALARM I40200 FEB 21, 2022 1:10 PM I40300 FEB 21, 2022 1:10 PM I34200 FEB 21, 2022 1:10 PM I34700 FEB 21, 2022 1:10 PM IV0100 FEB 21, 2022 1:10 PM FASTRIP 562 MING-CHESTER BAKERSFIELD CA 661-397-8606 ISD ALARM STATUS REPORT EVR TYPE: VACUUM ASSIST ISD TYPE: 01.02 VAPOR PROCESSOR TYPE: NONE OVERALL STATUS :FAIL EVR VAPOR COLLECTION :FAIL EVR VAPOR CONTAINMENT :WARN ISD MONITOR UP-TIME :100% STAGE I TRANSFERS: 1 of 1 PASS EVR/ISD PASS TIME : 0% WARNING ALARMS DATE TIME DESCRIPTION READING VALUE 22-02-21 10:01:43 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.10 22-02-20 10:01:42 A/L RATIO GROSS BLOCKAGE FP 4 BLEND3 BLKD 22-02-18 10:01:30 A/L RATIO GROSS BLOCKAGE FP 8 BLEND3 BLKD 22-02-18 10:01:30 A/L RATIO GROSS BLOCKAGE FP 2 BLEND3 BLKD 22-02-16 10:01:11 A/L RATIO GROSS BLOCKAGE FP 8 BLEND3 BLKD 22-02-15 10:01:10 A/L RATIO DEGRADATION FP 6 BLEND3 0.78 22-02-14 10:01:16 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.39 22-02-14 10:01:16 A/L RATIO DEGRADATION FP 6 BLEND3 0.77 22-02-14 10:01:16 A/L RATIO GROSS BLOCKAGE FP 2 BLEND3 BLKD 22-02-13 10:01:21 A/L RATIO DEGRADATION FP 6 BLEND3 0.79 FAILURE ALARMS DATE TIME DESCRIPTION READING VALUE 22-02-21 10:01:43 A/L RATIO GROSS BLOCKAGE FP 8 BLEND3 BLKD 22-02-21 10:01:42 A/L RATIO GROSS BLOCKAGE FP 2 BLEND3 BLKD 22-02-20 10:01:42 A/L RATIO GROSS BLOCKAGE FP 8 BLEND3 BLKD 22-02-20 10:01:41 A/L RATIO GROSS BLOCKAGE FP 2 BLEND3 BLKD 22-02-19 10:01:42 A/L RATIO GROSS BLOCKAGE FP 8 BLEND3 BLKD 22-02-19 10:01:42 A/L RATIO GROSS BLOCKAGE FP 2 BLEND3 BLKD 22-02-15 10:01:10 A/L RATIO GROSS BLOCKAGE FP 2 BLEND3 BLKD 22-01-30 11:49:09 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.71 21-12-29 11:49:27 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 1.66 21-04-11 11:49:09 A/L RATIO GROSS BLOCKAGE FP 6 BLEND3 BLKD SHUTDOWN & MISCELLANEOUS EVENTS DATE TIME DESCRIPTION ACTION/NAME 22-02-21 10:17:17 PUMPS MANUALLY RE-ENABLED 22-02-21 10:01:43 A/L RATIO GROSS BLOCKAGE DISABLED FP 08 BLEND3 22-02-21 10:01:42 A/L RATIO GROSS BLOCKAGE DISABLED FP 02 BLEND3 22-02-20 10:07:51 PUMPS MANUALLY RE-ENABLED 22-02-20 10:01:42 A/L RATIO GROSS BLOCKAGE DISABLED FP 08 BLEND3 22-02-20 10:01:41 A/L RATIO GROSS BLOCKAGE DISABLED FP 02 BLEND3 22-02-19 10:05:02 PUMPS MANUALLY RE-ENABLED 22-02-19 10:01:42 A/L RATIO GROSS BLOCKAGE DISABLED FP 08 BLEND3 22-02-19 10:01:42 A/L RATIO GROSS BLOCKAGE DISABLED FP 02 BLEND3 22-02-17 09:49:04 COLLECTION TEST HH08 GRADE TEST MANUALLY CLEARED ISD Setup. < IV4200 FEB 21, 2022 1:11 PM Sensor / Airflow Meter / Hose Table / Grade Table Relationship SS AA F1 FL M1H1L1 M2H2L2 M3H3L3 M4H4L4 F2 L2 M1H1L1 M2H2L2 M3H3L3 M4H4L4 02 01 02 01 030102 040102 100102 060000 03 02 030202 040202 100202 060000 03 02 04 03 030302 040302 100302 000000 05 04 030402 040402 100402 000000 04 03 06 05 030502 040502 100502 060000 07 06 030602 040602 100602 060000 05 04 08 07 030702 040702 100702 000000 09 08 030802 040802 100802 000000 > Jaco #5562 Alarm History After. Responses Received: I10200 FEB 21, 2022 3:11 PM FASTRIP 562 MING-CHESTER BAKERSFIELD CA 661-397-8606 SYSTEM CONFIGURATION SLOT BOARD TYPE POWER ON RESET CURRENT 1 7SMARTSENSOR BD 509328 508689 2 4 PROBE / G.T. 161808 161454 3 INTERSTITIAL BD 202847 202375 4 INTERSTITIAL BD 202871 202471 5 UNUSED 4718355 4710443 6 UNUSED 4717361 4701975 7 UNUSED 4715263 4702572 8 UNUSED 4709191 4706618 9 STP SENSE BOARD 33285 33233 10 RELAY BOARD 14947 14895 11 RELAY BOARD 15036 14984 12 UNUSED 4719178 4711575 13 UNUSED 4712774 4707552 14 UNUSED 4714717 4705694 15 UNUSED 4712598 4707375 16 UNUSED 4716528 4700344 COMM 1 RS232 SERIAL BD 14969 14917 COMM 2 RS232 SERIAL BD 15014 14984 COMM 3 ELEC DISP INT. 101433 101261 COMM 4 UNUSED 4715998 4706424 COMM 5 UNUSED 4712774 4701914 COMM 6 UNUSED 4713591 4703970 I90200 FEB 21, 2022 3:11 PM SOFTWARE REVISION LEVEL VERSION 336.02 SOFTWARE# 346336-100-C CREATED - 21.02.13.11.53 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD/APM I11100 FEB 21, 2022 3:11 PM FASTRIP 562 MING-CHESTER BAKERSFIELD CA 661-397-8606 PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME L13 PIPE TRAN NO. FUEL ALARM CLEAR 2-21-22 3:10PM L13 PIPE TRAN NO. FUEL ALARM ALARM 2-21-22 3:10PM L14 PIPE TRAN SO. FUEL ALARM CLEAR 2-21-22 3:10PM L14 PIPE TRAN SO. FUEL ALARM ALARM 2-21-22 3:09PM L 4 ANNULAR DIESEL ANN FUEL ALARM CLEAR 2-21-22 3:05PM L 4 ANNULAR DIESEL ANN FUEL ALARM ALARM 2-21-22 3:04PM L 4 ANNULAR DIESEL ANN FUEL ALARM CLEAR 2-21-22 3:03PM L 4 ANNULAR DIESEL ANN FUEL ALARM ALARM 2-21-22 2:58PM L 4 ANNULAR DIESEL ANN FUEL ALARM CLEAR 2-21-22 2:26PM L 4 ANNULAR DIESEL ANN FUEL ALARM ALARM 2-21-22 2:26PM L 4 ANNULAR DIESEL ANN FUEL ALARM CLEAR 2-21-22 2:14PM L 4 ANNULAR DIESEL ANN FUEL ALARM ALARM 2-21-22 2:13PM L 2 ANNULAR UNL1 ANN FUEL ALARM CLEAR 2-21-22 1:57PM L 2 ANNULAR UNL1 ANN FUEL ALARM ALARM 2-21-22 1:57PM L 8 ANNULAR UNL2 ANN FUEL ALARM CLEAR 2-21-22 1:56PM L 8 ANNULAR UNL2 ANN FUEL ALARM ALARM 2-21-22 1:56PM L10 DISP PAN DISP 3-4 FUEL ALARM CLEAR 2-21-22 1:50PM L10 DISP PAN DISP 3-4 FUEL ALARM ALARM 2-21-22 1:50PM L 6 ANNULAR PNL ANN FUEL ALARM CLEAR 2-21-22 1:50PM L 9 DISP PAN DISP 1-2 FUEL ALARM CLEAR 2-21-22 1:50PM L 9 DISP PAN DISP 1-2 FUEL ALARM ALARM 2-21-22 1:49PM L 6 ANNULAR PNL ANN FUEL ALARM ALARM 2-21-22 1:49PM L12 DISP PAN DISP 7-8 FUEL ALARM CLEAR 2-21-22 1:49PM L12 DISP PAN DISP 7-8 FUEL ALARM ALARM 2-21-22 1:49PM L11 DISP PAN DISP 5-6 FUEL ALARM CLEAR 2-21-22 1:48PM L11 DISP PAN DISP 5-6 FUEL ALARM ALARM 2-21-22 1:48PM L 7 STP SUMP UNL2 SIPON STP FUEL ALARM CLEAR 2-21-22 1:47PM L 7 STP SUMP UNL2 SIPON STP FUEL ALARM ALARM 2-21-22 1:47PM L 1 STP SUMP UNL 1 STP FUEL ALARM CLEAR 2-21-22 1:45PM L 1 STP SUMP UNL 1 STP FUEL ALARM ALARM 2-21-22 1:45PM L 3 STP SUMP DIESEL STP FUEL ALARM CLEAR 2-21-22 1:45PM L 3 STP SUMP DIESEL STP FUEL ALARM ALARM 2-21-22 1:45PM L 5 STP SUMP PNL STP FUEL ALARM CLEAR 2-21-22 1:45PM L 5 STP SUMP PNL STP FUEL ALARM ALARM 2-21-22 1:45PM L 8 ANNULAR UNL2 ANN SENSOR OUT ALARM CLEAR 2-21-22 1:43PM L 7 STP SUMP UNL2 SIPON STP SENSOR OUT ALARM CLEAR 2-21-22 1:43PM L 6 ANNULAR PNL ANN SENSOR OUT ALARM CLEAR 2-21-22 1:43PM L 4 ANNULAR DIESEL ANN SENSOR OUT ALARM CLEAR 2-21-22 1:43PM L 5 STP SUMP PNL STP SENSOR OUT ALARM CLEAR 2-21-22 1:43PM L 3 STP SUMP DIESEL STP SENSOR OUT ALARM CLEAR 2-21-22 1:43PM L10 DISP PAN DISP 3-4 SENSOR OUT ALARM CLEAR 2-21-22 1:43PM L 2 ANNULAR UNL1 ANN SENSOR OUT ALARM CLEAR 2-21-22 1:43PM L 9 DISP PAN DISP 1-2 SENSOR OUT ALARM CLEAR 2-21-22 1:43PM L 1 STP SUMP UNL 1 STP SENSOR OUT ALARM CLEAR 2-21-22 1:43PM L14 PIPE TRAN SO. SENSOR OUT ALARM CLEAR 2-21-22 1:43PM L12 DISP PAN DISP 7-8 SENSOR OUT ALARM CLEAR 2-21-22 1:43PM L13 PIPE TRAN NO. SENSOR OUT ALARM CLEAR 2-21-22 1:43PM L11 DISP PAN DISP 5-6 SENSOR OUT ALARM CLEAR 2-21-22 1:43PM L12 DISP PAN DISP 7-8 SENSOR OUT ALARM ALARM 2-21-22 1:43PM L11 DISP PAN DISP 5-6 SENSOR OUT ALARM ALARM 2-21-22 1:43PM I11200 FEB 21, 2022 3:11 PM FASTRIP 562 MING-CHESTER BAKERSFIELD CA 661-397-8606 NON-PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME SYSTEM PRINTER ERROR CLEAR 2-13-21 8:07AM SYSTEM PAPER OUT CLEAR 2-13-21 8:07AM SYSTEM PRINTER ERROR ALARM 2-13-21 8:06AM SYSTEM PAPER OUT ALARM 2-13-21 8:06AM I20600 FEB 21, 2022 3:11 PM FASTRIP 562 MING-CHESTER BAKERSFIELD CA 661-397-8606 TANK ALARM HISTORY TANK 1 UNL TANK 2 DIESEL TANK 3 PNL TANK 4 UNL 2 SIPHON TANK 5 TANK 6 TANK 7 TANK 8 TANK 9 TANK 10 TANK 11 TANK 12 TANK 13 TANK 14 TANK 15 TANK 16 I38200 FEB 21, 2022 3:11 PM I30200 FEB 21, 2022 3:11 PM FASTRIP 562 MING-CHESTER BAKERSFIELD CA 661-397-8606 LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 UNL 1 STP FEB 21, 2022 1:45 PM FUEL ALARM FEB 21, 2022 1:43 PM SENSOR OUT ALARM 2 UNL1 ANN FEB 21, 2022 1:57 PM FUEL ALARM FEB 21, 2022 1:43 PM SENSOR OUT ALARM 3 DIESEL STP FEB 21, 2022 1:45 PM FUEL ALARM FEB 21, 2022 1:43 PM SENSOR OUT ALARM 4 DIESEL ANN FEB 21, 2022 3:04 PM FUEL ALARM FEB 21, 2022 2:58 PM FUEL ALARM FEB 21, 2022 2:26 PM FUEL ALARM 5 PNL STP FEB 21, 2022 1:45 PM FUEL ALARM FEB 21, 2022 1:43 PM SENSOR OUT ALARM 6 PNL ANN FEB 21, 2022 1:49 PM FUEL ALARM FEB 21, 2022 1:43 PM SENSOR OUT ALARM 7 UNL2 SIPON STP FEB 21, 2022 1:47 PM FUEL ALARM FEB 21, 2022 1:43 PM SENSOR OUT ALARM 8 UNL2 ANN FEB 21, 2022 1:56 PM FUEL ALARM FEB 21, 2022 1:43 PM SENSOR OUT ALARM 9 DISP 1-2 FEB 21, 2022 1:49 PM FUEL ALARM FEB 21, 2022 1:43 PM SENSOR OUT ALARM 10 DISP 3-4 FEB 21, 2022 1:50 PM FUEL ALARM FEB 21, 2022 1:43 PM SENSOR OUT ALARM 11 DISP 5-6 FEB 21, 2022 1:48 PM FUEL ALARM FEB 21, 2022 1:43 PM SENSOR OUT ALARM 12 DISP 7-8 FEB 21, 2022 1:49 PM FUEL ALARM FEB 21, 2022 1:43 PM SENSOR OUT ALARM 13 TRAN NO. FEB 21, 2022 3:10 PM FUEL ALARM FEB 21, 2022 1:43 PM SENSOR OUT ALARM 14 TRAN SO. FEB 21, 2022 3:09 PM FUEL ALARM FEB 21, 2022 1:43 PM SENSOR OUT ALARM I31600 FEB 21, 2022 3:11 PM FASTRIP 562 MING-CHESTER BAKERSFIELD CA 661-397-8606 SMART SENSOR ALARM HISTORY REPORT SENSOR LOCATION 1 V.P.SENSOR DISP 3-4 2 F.M.DISP 1-2 3 F.M.DISP 3-4 4 F.M.DISP 5-6 5 F.M.DISP 7-8 I40200 FEB 21, 2022 3:11 PM I40300 FEB 21, 2022 3:11 PM I34200 FEB 21, 2022 3:11 PM I34700 FEB 21, 2022 3:11 PM IV0100 FEB 21, 2022 3:11 PM FASTRIP 562 MING-CHESTER BAKERSFIELD CA 661-397-8606 ISD ALARM STATUS REPORT EVR TYPE: VACUUM ASSIST ISD TYPE: 01.07 VAPOR PROCESSOR TYPE: NONE OVERALL STATUS :FAIL EVR VAPOR COLLECTION :FAIL EVR VAPOR CONTAINMENT :WARN ISD MONITOR UP-TIME :100% EVR/ISD PASS TIME : 0% WARNING ALARMS DATE TIME DESCRIPTION READING VALUE 22-02-21 10:01:43 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.10 22-02-20 10:01:42 A/L RATIO GROSS BLOCKAGE FP 4 BLEND3 BLKD 22-02-18 10:01:30 A/L RATIO GROSS BLOCKAGE FP 8 BLEND3 BLKD 22-02-18 10:01:30 A/L RATIO GROSS BLOCKAGE FP 2 BLEND3 BLKD 22-02-16 10:01:11 A/L RATIO GROSS BLOCKAGE FP 8 BLEND3 BLKD 22-02-15 10:01:10 A/L RATIO DEGRADATION FP 6 BLEND3 0.78 22-02-14 10:01:16 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.39 22-02-14 10:01:16 A/L RATIO DEGRADATION FP 6 BLEND3 0.77 22-02-14 10:01:16 A/L RATIO GROSS BLOCKAGE FP 2 BLEND3 BLKD 22-02-13 10:01:21 A/L RATIO DEGRADATION FP 6 BLEND3 0.79 FAILURE ALARMS DATE TIME DESCRIPTION READING VALUE 22-02-21 10:01:43 A/L RATIO GROSS BLOCKAGE FP 8 BLEND3 BLKD 22-02-21 10:01:42 A/L RATIO GROSS BLOCKAGE FP 2 BLEND3 BLKD 22-02-20 10:01:42 A/L RATIO GROSS BLOCKAGE FP 8 BLEND3 BLKD 22-02-20 10:01:41 A/L RATIO GROSS BLOCKAGE FP 2 BLEND3 BLKD 22-02-19 10:01:42 A/L RATIO GROSS BLOCKAGE FP 8 BLEND3 BLKD 22-02-19 10:01:42 A/L RATIO GROSS BLOCKAGE FP 2 BLEND3 BLKD 22-02-15 10:01:10 A/L RATIO GROSS BLOCKAGE FP 2 BLEND3 BLKD 22-01-30 11:49:09 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 3.71 21-12-29 11:49:27 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 1.66 21-04-11 11:49:09 A/L RATIO GROSS BLOCKAGE FP 6 BLEND3 BLKD SHUTDOWN & MISCELLANEOUS EVENTS DATE TIME DESCRIPTION ACTION/NAME 22-02-21 13:44:23 READINESS ISD:PF EVR:NNN CHECK ISD SENSORS 22-02-21 13:44:23 ISD STARTUP 22-02-21 13:44:10 ISD SHUTDOWN 22-02-21 13:35:00 TIME CHANGE DETECTED AT: 22-02-21 08:19:48 22-02-21 10:17:17 PUMPS MANUALLY RE-ENABLED 22-02-21 10:01:43 A/L RATIO GROSS BLOCKAGE DISABLED FP 08 BLEND3 22-02-21 10:01:42 A/L RATIO GROSS BLOCKAGE DISABLED FP 02 BLEND3 22-02-20 10:07:51 PUMPS MANUALLY RE-ENABLED 22-02-20 10:01:42 A/L RATIO GROSS BLOCKAGE DISABLED FP 08 BLEND3 22-02-20 10:01:41 A/L RATIO GROSS BLOCKAGE DISABLED FP 02 BLEND3