Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
310 Ohio Drive
February1,2022 SENTVIAUSMAILANDELECTRONICMAIL Applicant RobertoPerez 3715SycamoreCreekDrive Bakersfield,CA93313 PropertyOwner ClaudiaPinzon 1025CerritosDrive FullertonCA92835 RE:NoticeofDecisionSitePlanReview(ProjectNo.210432)(Ward1) DearMr.Perez: Theplanstoconstructa1,079squarefootADU(accessorydwellingunit)witha60squarefootattachedpatio coverinaR2(LimitedMultipleFamilyDwelling)zonedistrictlocatedat310Ohio,havebeenreviewed andconditionallyapproved.Thisletterprovidesalistofitemsrequiringyourattention. Oncethecorrectionsnotedintheattachedsiteplancompliancelisthavebeenmade,theproposalwillmeetthe minimumrequiredcodes,policiesandstandardsfordevelopmentasadoptedbytheBakersfieldCityCouncil. Specificitemshavebeenidentified(seeattachedSitePlanComplianceList)thatyouneedtoresolvebeforeyou canobtainabuildingpermitorbeallowedoccupancy.Theseitemsmayincludechangesoradditionsthatneed tobeshownonthefinalbuildingplans,alertyoutospecificfees,and/orarecommentsthatwillhelpyouin complyingwiththeĭźƷǤƭdevelopmentstandards.Eachitemwillnotewhenitistobecompletedandtheyhave beengroupedbydepartmentsothatyouknowwhomtocontactifyouhavequestions. Yournextstepistoeitherapplyfornecessarybuildingpermitstoconstructyourproject,orbeginyourbusiness activitiesdependingontherequestsubmitted.YoumustsubmitfinalbuildingplanstotheBuildingDivision. TheSitePlanReviewCommitteewillreviewthesefinalplanswhilebuildingplancheckoccurstoensurethatyou satisfytheitemsintheSitePlanComplianceList.Pleasereadthemcarefully.Failuretosatisfyanitemmay delayyourobtainingabuildingpermitorcommencingyourproject. AfterconstructionofyourprojectbutbeforetheCitycanallowoccupancy,theBuildingDivisionmustinspect thedevelopmenttofindifitcomplieswiththeapprovedplans,andanyotherrelevantpermitsandcodes.Ifyou havesatisfiedalloftherequirements,theBuildingDirectorwillissueacertificateofoccupancy;ifnot,thearea inspectorwillgiveyouacorrectionnotice.Onceyouhavemadeallofthecorrections,theBuildingDirectorcan issueacertificateofoccupancy.YoumaynotoccupyadevelopmentuntiltheBuildingDirectorhasissueda certificateofoccupancy. INDEMNIFICATIONCONDITION InconsiderationbytheCityofBakersfieldforlanduseentitlements,includingbutnotlimitedtorelated environmentalapprovalsrelatedtoorarisingfromthisproject,theapplicant,and/orpropertyownerand/or subdividerΛͻ!ƦƦƌźĭğƓƷͼherein)agreestoindemnify,defend,andholdharmlesstheCityofBakersfield,its officers, agents,employees,departments,commissionersandboardsΛͻ/źƷǤͼherein)againstanyandallliability, claims,actions,causesofactionsordemandswhatsoeveragainstthem,oranyofthem,beforeadministrativeor judicialtribunalsofanykindwhatsoever,inanywayarisingfrom,thetermsandprovisionsofthisapplication, includingwithoutlimitationanyCEQAapprovaloranyrelateddevelopmentapprovalsorconditionswhether imposedbytheCity,ornot,exceptfor/źƷǤƭsoleactivenegligenceorwillfulmisconduct. ThisindemnificationconditiondoesnotpreventtheApplicantfromchallenginganydecisionbytheCityrelated tothisprojectandtheobligationsofthisconditionapplyregardlessofwhetheranyotherpermitsor entitlementsareissued. TheCitywillpromptlynotifyApplicantofanysuchclaim,action,orproceeding,failingunderthiscondition withinthirty(30)daysofactuallyreceivingsuchclaim.TheCity,initssolediscretion,shallbeallowedtochoose theattorneyoroutsidelawfirmtodefendtheCityatthesolecostandexpenseoftheApplicantandtheCityis notobligatedtouseanylawfirmorattorneychosenbyanotherentityorparty. REVISIONSTOTHEAPPROVEDPLAN Anytimeaftersiteplanapprovalbutbeforetheapprovalexpires,youmaysubmitrevisionstotheplan.Wewill treattheserevisionsasanewsiteplanapplicationsubjecttoanewreviewandrequiredfees.ThePlanning Directorcanonlyapproveminorchangestotheoriginalplanwithoutanewapplicationiftheyarenecessaryto meetacondition,mitigation,orresultfromphysicalobstaclesorothercomparableconstraints(SeeSection 17.08.080.c.3oftheZoningOrdinance). EXPIRATIONOFPLANS ThissiteplanexpiresonFebruary25,2024(2yearsfromthedecisiondate),unlessbuildingpermitshavebeen issued,orwheretheusehascommencedonprojectsnotrequiringabuildingpermit.Theprojectmustbe completedwithin5yearsfromthedecisiondate.Ifthepropertyisrezoned,siteplanapprovalwillexpireupon theeffectivedatefortherezoningunlesstheuseispermittedinthenewzone. ThePlanningDirectormayextendtheexpirationdateuptoone(1)yearifyouresubmitnewplansforcheck againstthecoderequirementsineffectatthattimeandincludeawrittenrequestfortheextension.Wemust receivethisrequest before expirationoftheprojectapproval.Wewillnotrequireafeeforthisextension request;however,changestotheplansoriginallyapprovedforpurposesotherthancoderequirementsshallbe subjecttoanewsiteplanreview,includingpaymentofallrequiredfees(SeeSection17.08.080.DoftheZoning Ordinance). ENVIRONMENTALDETERMINATION ThissiteplanreviewhasbeenfoundtobeexemptfromtheprovisionsoftheCaliforniaEnvironmentalQuality Act(CEQA)accordingtoSection15303.TheprojectisexemptbecauseitisaClass3projectconsistingofanew constructionofasmallstructuremeetingtheconditionsdescribedinSection15303.ANoticeofExemptionhas beenpreparedandisavailableforreviewatthePlanningDivision. SPR210432Page|2of5 APPEAL Anypersonmayappealthisdecision.Anappealislimitedtowhetherornotanadopteddevelopmentstandard, zoningregulation,mitigation,orpolicyappliedornotappliedtotheproject,wasdoneconsistentwiththe authoritygrantedbycityordinancesortheCaliforniaEnvironmentalQualityAct(CEQA).Theappealmustbein eprecisebasisorissueasnoted,mustincludetheappropriatefilingfee,andmustbefiled writingstatingth within 10days ofthedecisiondatetotheCityofBakersfieldPlanningCommission(c/oBakersfieldPlanning Director,1715ChesterAvenue,Bakersfield,CA93301).ThePlanningCommissionwillholdapublichearingon theappealandtheirdecisionwillbefinalunlesstheirdecisionisappealedtotheCityCouncil. Siteplanapprovalisbasedonthestatementsmadeintheapplicationandtheplansyousubmitted.Anyerrors oromissionsontheseplanscouldalterthecompliancelistand/orvoidthisdecision.Ifyouhavequestions aboutanyoftheitemsnotedintheSitePlanComplianceList,youmustspeaktothecontactperson representingthedepartmentrequiringthatitem. Correspondencewillcontinuetobesenttotheapplicantonrecord.Shouldtheapplicantchange,itisthe propertyƚǞƓĻƩƭresponsibilitytoupdatethecontactinformationwiththePlanningDivision.Ifyouhaveother questionsregardinggeneralinformationaboutthesiteplanreviewprocess,pleasecontactthePlanningDivision at(661)3263733. DECISIONDATE:February25,2022 ly, Sincere LindaMitchell PrincipalPlanner cc:AllInterestedAgenciesΑForyourrecords. S:\\CounterOperations\\01_SPR\\2021\\210432_310OhioDr._ADU\\sprltr.docx SPR210432Page|3of5 CONDITIONSANDORDINANCECOMPLIANCE Thefollowingarespecificitemsthatyouneedtoresolvebeforeyoucanobtainabuildingpermitorbe allowedoccupancy.Theseitemsincludeconditionsand/ormitigationrequiredbyprevioussiteentitlement approvals(thesewillbespecificallynoted),changesoradditionsthatneedtobeshownonthefinalbuilding plans,alertyoutospecificfees,andotherconditionsforyourprojecttosatisfythe/źƷǤƭdevelopment standards. Theitemslistedbelowwillusuallyneedtobeshownonthefinalbuildingplansorcompletedbeforea buildingpermitisissued.Aspartofthebuildingpermitsubmittal,identifythelocationofyourresponseby usingthe!tt\[L/!b{RESPONSE lineprovideddirectlybelowtheitem(example:sheetnumber,detail,etc.). DEVELOPMENTSERVICESPLANNING(1715ChesterAvenue) (StaffcontactPatStowe;6613263679orPStowe@bakersfieldcity.us) 1.TheBuildingDivisionandPublicWorksDepartmentwillcalculateandcollecttheappropriatefee(s)at thetimebuildingpermitsareissued. !tt\[L/!b{RESPONSE:__________________________________________________________ 2.Thedevelopershallconnecttothepublicsewersystem.Thisconnectionshallbeshownonthefinal buildingplanssubmittedtotheBuildingDivisionbeforeanybuildingpermitswillbeissued. !tt\[L/!b{RESPONSE:__________________________________________________________ 3.Showonthefinalsiteplanhowandwherewaterwillbedrainedfromtheproperty. !tt\[L/!b{RESPONSE:__________________________________________________________ 4.Stateonthefinalbuildingplanhowtheaccessorydwellingunitshallbearchitecturallycompatiblewith themainhomeasshownintheapprovedsiteplanapplication.Architecturalcompatibilityshallmean thattheexteriorbuildingmaterialsandarchitecturalstyleoftheaccessorydwellingunitaresimilarto thebasicstyleandmaterialsusedforthemainhome. !tt\[L/!b{RESPONSE:__________________________________________________________ 5.TheaccessorydwellingunitshallconformtotheconstructionrequirementsoftheBuildingCodeas adoptedbythecity.Ifanexistingbuilding,aSpecialInspectionPermitisrequiredtodeterminewhat correctionsareneededtosatisfyminimumbuilding,plumbing,electrical,and/ormechanicalcode standards(generallyappliestoexistingbuildings). !tt\[L/!b{RESPONSE:__________________________________________________________ 6.Iftheaccessorydwellingunitisattachedtotheexistingsinglefamilydwelling,thefloorareashallnot exceed50percentofthefloorareaoftheexistingdwelling;ifdetachedfromtheexistingsinglefamily dwelling,thefloorareashallnotexceed1,200squarefeet. !tt\[L/!b{RESPONSE:__________________________________________________________ SPR210432Page|4of5 7.Exceptasotherwiseprovided,thereshallbeafrontyardofnotlessthan15feetindepthmeasured fromthefrontlotline.Ifagarageopeningfacesapublicstreet,thegarageshallbesetbacknotlessthan 20feet. !tt\[L/!b{RESPONSE:__________________________________________________________ 8.Exceptasotherwiseprovided,thereshallbeasideyardforthemainbuildingofnotlessthan5feet.For cornerlots,thesideyardonthestreetsidefrontageshallnotbelessthan10feet. !tt\[L/!b{RESPONSE:__________________________________________________________ 9.Exceptasotherwiseprovided,thereshallbearearyard behindeverymainbuildingofnotlessthan25 feetor20percentofthedepthofthelot,whicheverisless;provided,however,therearyardmaybe reducedto5feetifnotmorethan45percentofthelotiscoveredwithbuildingsorstructures. !tt\[L/!b{RESPONSE:__________________________________________________________ 10.Theminimumparkingrequiredforthisprojectarecalculatedbasedonthefollowing: PrimaryResidence.Twoparkingspacesarerequired.IfconstructedpriortoMarch15,1971, thenoneparkingspaceisrequired.Parkingshallbelocatedoffstreetandoutsidethefrontyard setback.Whenagarage,carport,orcoveredparkingstructureisdemolishedorconvertedtoan accessorydwellingunit,noreplacementparkingspacesarerequired. AccessoryDwellingUnit.Oneparkingspaceisrequired.Iflocatedwithin1/2mileofpublic transit,noparkingspacesarerequired.Ifpartoftheprimaryresidenceorpartofanaccessory structure,noparkingspacesarerequired.Parkingmaybepermittedinsetbackareasas determinedbyCitystaff.Plansmustshowthelocationofthetransitwithdistancemarkings fromtheaccessorydwellingunit. Tandemspacesarepermitted. Compactspacescannotbecountedtowardmeetingminimumparkingrequirements. !tt\[L/!b{RESPONSE:__________________________________________________________ 11.Allparkinglots,driveways,andothervehicularaccessways,shallbepavedwithconcrete,asphaltic concreteorotherpavedstreetsurfacingmaterialinaccordancewiththeBakersfieldMunicipalCode (Sections15.76.020and17.58.060.A).StateonallfinalBuildingplansthetypeofpaving. !tt\[L/!b{RESPONSE:__________________________________________________________ SPR210432Page|5of5