Loading...
HomeMy WebLinkAbout2022-02-03 989 Appendix VII Underground Storage Tank Secondary Containment Testing Report Form CERS = California Environmental Reporting System, ICC = International Code Council, ID = Identification, NA = Not Applicable, UDC = Under-Dispenser Containment, Page 1 of 5 TYPE OF ACTION ܆܆ Installation ܆ Repair ܆ 6 Month ܆ 36 Month CERS ID Test Date Facility Name Facility Address City ZIP Code Company Performing the Test Phone Mailing Address Service Technician Performing Test Contractor/Tank Tester License Number ICC Number ICC Expiration Date Manufacturer and Test Equipment Training Certifications Expiration Date Test Procedures Used Components Tested I hereby certify that the secondary containment was tested in accordance with California Code of Regulations, title 23, division 3, chapter 16, section 2637; that required supporting documentation is attached; and all information contained herein is accurate. I understand that test procedures shall be made available upon request by the governing authority. Service Technician Signature Date Total # of Pages 1. FACILITY INFORMATION 2. SERVICE TECHNICIAN INFORMATION 3. TRAINING AND CERTIFICATIONS 4. TEST PROCEDURE INFORMATION 5. CERTIFICATION BY SERVICE TECHNICIAN CONDUCTING TEST 10123120 2/3/2022 Wash Depot Holdings, Inc. 2301 H Street Bakersfield 93301 Confidence UST Services, Inc.(800) 339-9930 2209 Zeus Court, Bakersfield, CA 93308 Terrence Lay 1073967 8721725 08/10/2022 INCON 10142003709 2/7/2024 Incon Sumps and UDC’s Precision mechanical test gauge Tank annular’s and line secondaries 2/3/2022 5 Underground Storage Tank Secondary Containment Testing Report Form All tests marked “Fail” and any repairs made before or during the tightness test must be described in the COMMENTS section. Page 2 of 5 Test Method Developed by ܆܆ Manufacturer ܆܆ Industry Standard ܆܆ Professional Engineer Test Type ܆܆ Pressure ܆܆ Vacuum ܆܆ Hydrostatic Test Equipment Used: Tank ID Tank Manufacturer Tank Capacity Test Start Time Initial Reading Test End Time Final Reading Change in Reading Pass/Fail Criteria Tightness Test Results ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail Test Method Developed by ܆܆ Manufacturer ܆܆ Industry Standard ܆܆ Professional Engineer Test Type ܆܆ Pressure ܆܆ Vacuum ܆܆ Hydrostatic Test Equipment Used: Pipe Run ID Pipe Manufacturer Test Start Time Initial Reading Test End Time Final Reading Change in Reading Pass/Fail Criteria Tightness Test Results ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail Pipe Run ID Pipe Manufacturer Test Start Time Initial Reading Test End Time Final Reading Change in Reading Pass/Fail Criteria Tightness Test Results ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail ܆܆ Pass ܆܆ Fail Additional copies of this page may be attached. 6. TANK SECONDARY CONTAINMENT TEST 7. PIPE SECONDARY CONTAINMENT TEST Vacuum Gauge 87 Unleaded 12,000 11:30 -15inhg 12:00pm -15inhg 0 0 Pressure Gauge 87 Product NOV/Smith 9:00am 5 psi 9:30am 5psi 0 0 Diesel Product NOV/Smith 10:00am 5 psi 10:30 5 psi 0 0 91 Premium 12,000 11:30 -12inhg 12:00 -12inhg 0 0 Diesel 12,000 11:30 -17inhg 12:00 -17inhg 0 0 87 Vent NOV/Smith 9:00am 5 psi 9:30am 5 psi 0 0 91 Product NOV/Smith 9:00 am 5psi 9:30am 5 psi 0 0 91 Vent NOV/Smith 9:00 am 5 psi 9:30 am 5 psi 0 0 Diesel Vent NOV/Smith 10:00am 5 psi 10:30 5 psi 0 0 87 Vapor Return NOV/Smith 10:30am 5 psi 10:30 5 psi 0 0 91 Vapor Return NOV/Smith 10:30am 5 psi 10:30 5 psi 0 0 Underground Storage Tank Secondary Containment Testing Report Form All tests marked “Fail” and any repairs made before or during the tightness test must be described in the COMMENTS section. Page 3 of 5 Test Method Developed by ܆܆ Manufacturer ܆ Industry Standard ܆ Professional Engineer Test Type ܆ Pressure ܆ Vacuum ܆ Hydrostatic Test Equipment Used: Sump/UDC ID Sump Manufacturer Sump Depth (inches) Sump Bottom to Top of Highest Pipe Penetration (inches) Test Start Time Initial Reading Test End Time Final Reading Change in Reading Pass/Fail Criteria Tightness Test Results ܆ Pass ܆܆ Fail ܆ Pass ܆܆ Fail ܆ Pass ܆܆ Fail ܆ Pass ܆܆ Fail Sump/UDC ID Sump Manufacturer Sump Depth (inches) Sump Bottom to Top of Highest Pipe Penetration (inches) Test Start Time Initial Reading Test End Time Final Reading Change in Reading Pass/Fail Criteria Tightness Test Results ܆ Pass ܆܆ Fail ܆ Pass ܆܆ Fail ܆ Pass ܆܆ Fail ܆ Pass ܆܆ Fail Additional copies of this page may be attached. 8. SUMP/UDC TEST Incon 87 STP OPW 38” 18” 11:58 am 5.3588 in 12:13 pm 5.3587 in 0.0001 in 0.002 in UDC 3-4 Western Fiberglass 28” 15” 12:28 pm 2.3453 in 12:43 pm 2.3453 in 0in 0.002 in 91 STP OPW 38” 16” 11:58 am 4.9295 in 12:13 pm 4.9294 in 0.0001 in 0.002 in Diesel STP OPW 38” 19” 2:12 pm 2.0402 in 2:28 pm 2.0399 0.0003 in 0.002 in UDC 1/2 Western Fiberglass 28” 15” 12:28 pm 8.3526 in 12:43 pm 8.3528 in 0.0002 in 0.002 in UDC 5-6 Western Fiberglass 28” 15” 12:28 pm 2.8044 in 12:43 pm 2.8059 in 0.0015 in 0.002 in UDC 7-8 Western Fiberglass 28” 15” 2:45 pm 3.0719 in 3:00 pm 3.0726 in 0.0007 in 0.002 in UDC 9-10 Western Fiberglass 28” 15” 2:45 pm 3.0693 in 3:00 pm 3.0689 in 0.0004 in 0.002 in Underground Storage Tank Secondary Containment Testing Report Form All tests marked “Fail” and any repairs made before or during the tightness test must be described in the COMMENTS section. Page 4 of 5 Test Method Developed by ܆܆ Manufacturer ܆ Industry Standard ܆ Professional Engineer Test Type ܆ Pressure ܆ Vacuum ܆ Hydrostatic Test Equipment Used: Sump/UDC ID Sump Manufacturer Sump Depth (inches) Sump Bottom to Top of Highest Pipe Penetration (inches) Test Start Time Initial Reading Test End Time Final Reading Change in Reading Pass/Fail Criteria Tightness Test Results ܆ Pass ܆܆ Fail ܆ Pass ܆܆ Fail ܆ Pass ܆܆ Fail ܆ Pass ܆܆ Fail Sump/UDC ID Sump Manufacturer Sump Depth (inches) Sump Bottom to Top of Highest Pipe Penetration (inches) Test Start Time Initial Reading Test End Time Final Reading Change in Reading Pass/Fail Criteria Tightness Test Results ܆ Pass ܆܆ Fail ܆ Pass ܆܆ Fail ܆ Pass ܆܆ Fail Additional copies of this page may be attached. 8. SUMP/UDC TEST (continued) ܆ Pass ܆ Fail Incon UDC 11-12 Western Fiberglass 28” 15” 1:33 pm 1.5986 in 1:48 pm 1.5989 in 0.0003 in 0.002 in UDC 13-14 Western Fiberglass 28” 15” 1:33 pm 5.2276 in 1:48 pm 5.2281 in 0.0005 in 0.002 in UDC 15-16 Western Fiberglass 28” 15” 1:33 pm 3.8137 in 1:48 pm 3.8139 in 0.0002 in 0.002 in Underground Storage Tank Secondary Containment Testing Report Form All tests marked “Fail” and any repairs made before or during the tightness test must be described in the COMMENTS section. Page 5 of 5 9. COMMENTS