HomeMy WebLinkAboutFire Safety 3-14-22FIRE PREVENTION INSPECTION
BAKERSFIELD FIRE DEPARTMENT
Prevention Services
2101 H Street
Bakersfield, CA 93301
Phone: 661-326-3979 • Fax: 661-852-2171
FACILITY ADDRESS CAoFr-�
DATE �FEE
CI1X, STAT ZIP
451<re_,P_>_cA q33q�
FACILITY NAME P-J&
� ` , i � � �
;�r\, P,7ngaz�
BUSINESS OWNER'S NAME AND ADDRESS
MANAGER'S NAME PH NO.
BILL TO: (IF DIFFERENT FROM ABOVE) NAME, ADDRESS
CITY, STATE, ZIP PH NO.
OCC TYPE
OCC LOAD
NO. OF FLOORS
OCC USE
RISER DATE
Wet/Dry Sprinkler System
Type of Alarm System
CONSTRUCTION TYPE
HIGH RISE BLDG SQ/FT OF BLD
CORRECT ALL VIOLATIONS VIOLATION
REQUIREMENTS
CHECKED BELOW No.
1
Remove and safely dispose of all hazardous refuse and dry vegetation on the above premises (CFC
COMBUSTIBLE WASTE /DRY
304.1.1)
VEGETATION
2
Provide non-combustible containers with tight fitting lids for the storage of combustible waste and
rubbish pending its safe disposal. (CFC 304.3.2) Note: applies to containers over 40 gallons.
COMBUSTIBLE STORAGE
3
Relocate combustible storage to provide at least 3 feet clearance around motor fuse box/fire door (CFC
604.3)
4
Relocate fire extinguisher(s) so that they will be in a conspicuous location, hanging on brackets with the
top to the extinguisher not more than 5 feet above the floor. (CFC 906.5 & 906.9)
EXTINGUISHERS
5
Provide and install (amount) --___ approved (type & size) __________________ portable fire
extinguisher to be immediately accessible for use in (area) ---------------------__------- (CFC
TABLE 906.3)
6
Re -charge all fire extinguishers. Fire extinguishers shall be serviced at least once each year, and/or
after each use, by a person having a valid license or certificate. (CFC 906.2)
7
Provide and maintain "EXIT" sign(s) with letters 6 or more inches in height over each required exit
SIGNS
(door/window) to fire escape. (CFC 1013.6.1)
8
Provide and maintain appropriate numbers on a contrasting background and visible from the street to
indicate the correct address of the building. (CFC 505.1)
g
Repair all (cracks/holes/openings) in plaster in (location)
FIRE DOORS/
FIRE SEPARATIONS
______________________________________,
Plasteringshall return the surface to its original fire resistive condition. CFC 703.1
9 ( )
10
Remove/repair Item & location
Self-closing doors shall be designed to close by gravity, or by the action of a mechanical device, or by an
approved smoke and heat sensitive device. Self-closing doors shall have no attachments capable of
preventing the operation of the closing device. (CFC 705.2.4)
EXITS
11
Remove all obstruction from hallways. Maintain all means of egress free of any storage. (CFC 1031.3)
12
Provide a contrasting colored and permanently installed electric light over or near required exit
(location) ------------------------------ to clearly indicate it as an exit. (CFC 10 0 8)
STORAGE
13
Remove all storage and/or other obstructions from fire escape landings and stairways stair shafts. (Fire
escapes/stair shafts are to be maintained free from obstructions at all times.) (CFC 1003.6)
14
Extension cords shall not be used in lieu of permanent approved wiring. Install additional approved
ELECTRICAL APPLIANCES
electrical outlets where needed. (CFC 604.5)
15
Remove multiple attachment cords from specific electrical convenience outlet (one plug per outlet) (CFC
604.4.2)
Commercial Hood
16
Automatic Fire Extinguishing systems shall be serviced at least every 6 months (CFC 904.12.5.2
17
Commercial cooking systems shall be operated and maintained in accordance with code (CFC 607)
OTHER
18
Violations of Section (CFC 5608.1) & 8.44.040 (B.M.C.).
C_.�_^�
CORRECTION D TE
--,.
Correct .t -he violations noted above by:
CUSTOMER: '� �� �,t �,'^�
LEGEND:
(Signature) lease Print Name Legibl , Title)
C.F.C. CALIFORNIA FIRE CODE
C.B.C. CALIFORNIA BUILDING CODE
B.M.C. BAKERSFIELD MUNICIPAL CODE
INSPECTOR: i , '' i NO.
N. F. P. A. NATIONAL FIRE PROTECTION
ASSOCIATION
N.E.C. NATIONAL ELECTRIC CODE
White - Prevention Services Yellow - Station Copy Pink - Business Copy