Loading...
HomeMy WebLinkAboutFMC 2022Appendix VI Underground Storage Tank  Monitoring System Certification Form CERS = California Environmental Reporting System, GPH = Gallons Per Hour, ID = Identification, ICC = International Code Council, LLD = Line Leak Detector, NA = Not Applicable, SW = Single- Walled, UDC = Under-Dispenser Containment, UST = Underground Storage Tank, VPH = Vacuum/Pressure/Hydrostatic Page 1 of 6 TYPE OF ACTION Installation Repair 12 Month 1. FACILITY INFORMATION CERS ID Certification Date Facility Name Facility Address City ZIP Code 2. SERVICE TECHNICIAN INFORMATION Company Performing the Certification Phone Mailing Address Service Technician Performing Test Contractor/Tank Tester License Number ICC Number ICC Expiration Date 3.TRAINING AND CERTIFICATIONS Manufacturer and Test Equipment Training Certifications Expiration Date 4.CERTIFICATION BY SERVICE TECHNICIAN CONDUCTING TEST I hereby certify that the monitoring system is operational in accordance with California Code of Regulations, title 23, division 3, chapter 16, section 2638; that required supporting documentation is attached; and all information contained herein is accurate. Service Technician Signature Date Total # of Pages Underground Storage Tank  Monitoring System Certification Form Page 2 of 6 5.MONITORING SYSTEM AND PROGRAMMING A separate Monitoring System Certification Form must be prepared for each control panel. Make of Monitoring System Control Panel Model of Monitoring System Control Panel Software Version Installed Attach the post-certification reports if the monitoring system is capable of generating either; Monitoring System Set-up Alarm History Report Yes No NA All monitoring equipment is operational per manufacturer’s specifications? Secondary containment systems are free of damage, debris, or liquid? Are the audible and visual alarms operational? All sensors have been: 1) visually inspected for wiring kinks, breaks and residual buildup on floats; and 2) tested for functionality and confirmed operational? Are all sensors installed to detect a release at the earliest opportunity in the secondary containment? The monitoring system set-up was reviewed, and proper settings confirmed? Was the monitoring control panel’s backup battery visually inspected, functionally tested, and confirmed operational? Does the flow of fuel stop at the dispenser if a release is detected in the under- dispenser containment? Does the turbine automatically shut down if the piping secondary containment monitoring system fails to operate or is electrically disconnected? Does the turbine automatically shut down if the piping secondary containment monitoring system detects a release? Which sensors initiate positive shut down? (Check all that apply) Sump UDC If monitoring system alarms are relayed to a remote monitoring center, is all communication equipment operational? Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 Underground Storage Tank  Monitoring System Certification Form Page 3 of 6 6. SENSOR TESTING RESULTS List only sensors tested on date of this certification. List “Sensor ID” as labeled in system programming. Additional copies of this page may be attached to accommodate all sensors tested. Sensor ID Sensor Model Component(s) Monitored Pass Fail Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 Underground Storage Tank  Monitoring System Certification Form Page 4 of 6 7. LINE LEAK DETECTOR TESTING Check this box if line leak detectors ARE NOT installed. (Do not complete this section.) Simulated release rate verified: (Check all that apply.) 3 GPH 0.1 GPH 0.2 GPH Yes No NA Has the testing apparatus been properly calibrated? For emergency generator tank systems, does the LLD create an audible and visual alarm when a leak is detected? For mechanical LLDs, does the LLD restrict the flow through the pipe when a release is detected? For electronic LLDs, does the turbine automatically shut off when a release is detected? For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system is disabled or disconnected? For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system malfunctions or fails a tightness test? For electronic LLDs, have all accessible wiring connections been visually inspected for kinks and breaks? Were all items on the equipment manufacturer’s maintenance checklist completed? Were all LLDs confirmed operational within regulatory requirements? LLD ID LLD Model Lines Monitored Pass Fail Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 Underground Storage Tank  Monitoring System Certification Form Page 5 of 6 8. IN-TANK GAUGING TESTING Check this box if tank gauging is used only for inventory control. Check this box if NO tank gauging equipment is installed. (Do not complete this section if either box is checked.) Yes No NA All wiring has been: 1) visually inspected for kinks, breaks and proper entry and termination; and 2) tested for ground faults? Were all in-tank gauging probes visually inspected for damage and residue buildup to ensure that floats move freely, functionally tested, and confirmed operational? Was accuracy of system’s product level readings tested? Was accuracy of system’s water level readings tested? Were all probes reinstalled properly? Were all items on the equipment manufacturer’s maintenance checklist completed? Probe ID Probe Model Tanks Monitored Pass Fail 9. COMMENTS Describe all answers marked “No” or “Fail” and proposed remedy. List all monitoring equipment either replaced or repaired. lllonitoring System Certifi cation UST Monitoring Site Plan site Address: 8803 Camino Media, Bakersfield, CA. 93311 ,,,'l:'. ',,,,1.,,.,r.s ?I? . at v,1 . . 1ltai)! ? +L.t . . .Ax?:t" z,rg. ' 'sf unEq@ ,m"si- oi. . .. .'*45.)r. ./(v........ -.LTD , o'"*t, ..... .. Lro . . . ,4.'^t"tJ. .. -:-, 7<ltl1tlo -:4:2i ie.A5:.( >tt/(. -: .. { :: Date map was draw l l_. Instructlons If you already have a diagram that shows all required information, you may include it, rather thar this page, with your Molritoring System Certification- On your site plan, show the general layout of tatrks and piping. Ctearly identifu locations of the following equipment, if installed: monitoring system control parels; sensors monitoring tank annular spacesr sumps, dispenser pans, spill containers, or other secondary containment areas; mechaaical or electronic line leak detectors; and in+ank liquid level probes (ifused for leak detection). In the space provided, note the date this Site Plan lyas prepared. Page 4 of 4 rrr"_w.unidocs.orguN-035 - 4/.1 Rev.0l/17l0E . r;4r\,a 03 17 22 CVE Cal- Valley Equipment 3500 Gilmore Ave. Bakersfield CA 93308 661 -327-9341 FAX# 661 -325-2529 VAPORLESS MANUFACTURING, INC. LDT-890 Leak Detector Test Record Technician Date Pass / Fail Product Manufacturer Leak rate Operating pressure Line pressure (pump off) Facility Address Bleed back (pump off) Step through time to full flow Stays in leak search position file:///C/Users/jerryr/Desktop/03-17-22%20Oaks%20-%20Monitor/Cougar%20monitor.txt[3/17/2022 11:44:19 AM] < I20100MAR 17, 2022 8:25 AM BROOKSIDE MARKET 8803 CAMINO MEDIA BAKERSFIELD CA 93311 IN-TANK INVENTORY TANK PRODUCT VOLUME TC VOLUME ULLAGE HEIGHT WATER TEMP 1 UNLEADED 10471 10441 9611 65.89 1.12 63.93 2 PREMIUM 4863 4844 7178 54.09 0.00 65.48 3 DIESEL 4311 4298 3716 67.46 0.00 66.10 > <I90500 MAR 17, 2022 8:26 AMSOFTWARE REVISION LEVEL VERSION 336.02SOFTWARE# 346336-100-C CREATED - 21.02.13.11.53 S-MODULE# 330160-004-aSYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD/APM >< I50201MAR 17, 2022 8:26 AM SHIFT TIME 1 : 11:00 PM > <I50202 MAR 17, 2022 8:26 AM SHIFT TIME 2 : DISABLED >< I50203MAR 17, 2022 8:26 AM SHIFT TIME 3 : DISABLED > file:///C/Users/jerryr/Desktop/03-17-22%20Oaks%20-%20Monitor/Cougar%20monitor.txt[3/17/2022 11:44:19 AM] < I50204MAR 17, 2022 8:26 AM SHIFT TIME 4 : DISABLED > <I54600 MAR 17, 2022 8:26 AM TANK PER TST NEEDED WRN: DISABLED >< I54900MAR 17, 2022 8:26 AM TANK ANN TST NEEDED WRN: DISABLED > <I55300 MAR 17, 2022 8:26 AM LINE RE-ENABLE METHODPASS LINE TEST > <I55600 MAR 17, 2022 8:26 AM LINE PER TST NEEDED WRN: DISABLED >< I55900MAR 17, 2022 8:26 AM LINE ANN TST NEEDED WRN: DISABLED > <I51400 MAR 17, 2022 8:26 AM H-PROTOCOL DATA FORMATHEIGHT > <I51A01 MAR 17, 2022 8:27 AM file:///C/Users/jerryr/Desktop/03-17-22%20Oaks%20-%20Monitor/Cougar%20monitor.txt[3/17/2022 11:44:19 AM] DAYLIGHT SAVING TIMEENABLED OFF > <I51B00 MAR 17, 2022 8:27 AM DAYLIGHT SAVING TIME START DATE APR WEEK 1 SUN 2:00 AM END DATE OCT WEEK 6 SUN 2:00 AM >< I51600MAR 17, 2022 8:27 AM RE-DIRECT LOCAL PRINTOUT DISABLED >< I50400MAR 17, 2022 8:27 AM 232 SECURITY CODE PORT SECURITY CODE STATUS 1 000000 DISABLED 2 000000 DISABLED 3 000000 DISABLED 4 000000 DISABLED 5 000000 DISABLED 6 000000 DISABLED >< I21900MAR 17, 2022 8:27 AM TANK CHART SECURITY ENABLED >< I5BD00MAR 17, 2022 8:27 AM file:///C/Users/jerryr/Desktop/03-17-22%20Oaks%20-%20Monitor/Cougar%20monitor.txt[3/17/2022 11:44:19 AM] CUSTOM ALARM LABELS DISABLED > <I56000 MAR 17, 2022 8:27 AM MASS/DENSITY DISABLED >< I88101MAR 17, 2022 8:27 AM PORT SETTINGS: COMM BOARD : 1 (EDIM )RS-232 SECURITY CODE : ****** >< I88102MAR 17, 2022 8:27 AM PORT SETTINGS: COMM BOARD : 2 (S-SAT ) BAUD RATE : 9600 PARITY : NONE STOP BIT : 1 STOP DATA LENGTH: 8 DATARS-232 SECURITY CODE : ****** DTR NORMAL STATE: HIGH > <I88103 MAR 17, 2022 8:27 AMPORT SETTINGS: COMM BOARD : 3 (RS-232) BAUD RATE : 9600 PARITY : NONE STOP BIT : 1 STOP DATA LENGTH: 8 DATA RS-232 SECURITYCODE : ****** > < file:///C/Users/jerryr/Desktop/03-17-22%20Oaks%20-%20Monitor/Cougar%20monitor.txt[3/17/2022 11:44:19 AM] I60100 MAR 17, 2022 8:27 AM TANK CONFIGURATION DEVICE LABEL CONFIGURED 1 UNLEADED ON 2 PREMIUM ON 3 DIESEL ON 4 HACKED OFF >< I60200MAR 17, 2022 8:27 AM TANK PRODUCT LABEL TANK PRODUCT LABEL 1 UNLEADED 2 PREMIUM 3 DIESEL 4 HACKED >< I60300MAR 17, 2022 8:27 AM TANK PRODUCT CODE TANK PRODUCT LABEL 1 UNLEADED 1 2 PREMIUM 2 3 DIESEL 3 4 HACKED 4 >< I60900MAR 17, 2022 8:27 AM TANK THERMAL COEFFICIENT TANK PRODUCT LABEL 1 UNLEADED 0.000700 2 PREMIUM 0.000700 3 DIESEL 0.000450 4 HACKED 0.000000 >< I60700MAR 17, 2022 8:27 AM TANK DIAMETER file:///C/Users/jerryr/Desktop/03-17-22%20Oaks%20-%20Monitor/Cougar%20monitor.txt[3/17/2022 11:44:19 AM] TANK PRODUCT LABEL INCHES 1 UNLEADED 127.50 2 PREMIUM 127.50 3 DIESEL 127.50 4 HACKED 0.00 >< I60A00MAR 17, 2022 8:27 AM TANK FULL VOLUME TANK PRODUCT LABEL TANK PROFILE GALLONS 1 UNLEADED 1 PT 20082 2 PREMIUM 1 PT 12041 3 DIESEL 1 PT 8027 4 HACKED 1 PT 111111 >< I60400MAR 17, 2022 8:27 AM TANK FULL VOLUME TANK PRODUCT LABEL GALLONS 1 UNLEADED 20082 2 PREMIUM 12041 3 DIESEL 8027 4 HACKED 111111 >< I60500MAR 17, 2022 8:27 AM TANK 4 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 UNLEADED 20082 0 0 0 2 PREMIUM 12041 0 0 0 3 DIESEL 8027 0 0 0 4 HACKED 111111 0 0 0 > <I60600 MAR 17, 2022 8:27 AM TANK 20 POINT VOLUMES file:///C/Users/jerryr/Desktop/03-17-22%20Oaks%20-%20Monitor/Cougar%20monitor.txt[3/17/2022 11:44:19 AM] TANK PRODUCT LABEL GALLONS 1 UNLEADED 20082 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 PREMIUM 12041 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3 DIESEL 8027 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4 HACKED 111111 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 >< I61500MAR 17, 2022 8:27 AM TANK PRODUCT LABEL METER DATA 1 UNLEADED NO 2 PREMIUM NO 3 DIESEL NO 4 HACKED NO > <I62F00 MAR 17, 2022 8:27 AM MAG PROBE FLOAT SIZE TANK PRODUCT LABEL FLOAT SIZE: 1 UNLEADED 4.0 IN. 2 PREMIUM 4.0 IN. 3 DIESEL 4.0 IN. > <I62700 MAR 17, 2022 8:28 AM TANK HIGH WATER WARNING LIMIT TANK PRODUCT LABEL INCHES file:///C/Users/jerryr/Desktop/03-17-22%20Oaks%20-%20Monitor/Cougar%20monitor.txt[3/17/2022 11:44:19 AM] 1 UNLEADED 2.0 2 PREMIUM 2.0 3 DIESEL 2.0 >< I64200MAR 17, 2022 8:28 AM WATER ALARM FILTER TANK PRODUCT LABEL 1 UNLEADED LOW 2 PREMIUM LOW 3 DIESEL LOW >< I62400MAR 17, 2022 8:28 AM TANK HIGH WATER LEVEL LIMIT TANK PRODUCT LABEL INCHES 1 UNLEADED 3.0 2 PREMIUM 3.0 3 DIESEL 3.0> <I62800 MAR 17, 2022 8:28 AM TANK MAXIMUM VOLUME LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 20082 2 PREMIUM 12041 3 DIESEL 8027 4 HACKED 111111> <I62300 MAR 17, 2022 8:28 AM TANK OVERFILL LEVEL LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 18074 2 PREMIUM 10837 3 DIESEL 7224 4 HACKED 0> <I62200 MAR 17, 2022 8:28 AM file:///C/Users/jerryr/Desktop/03-17-22%20Oaks%20-%20Monitor/Cougar%20monitor.txt[3/17/2022 11:44:19 AM] TANK HIGH PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 19078 2 PREMIUM 11439 3 DIESEL 7626 4 HACKED 0> <I62900 MAR 17, 2022 8:28 AM TANK DELIVERY REQUIRED LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 2008 2 PREMIUM 1204 3 DIESEL 803 4 HACKED 0> <I62100 MAR 17, 2022 8:28 AM TANK LOW PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 500 2 PREMIUM 500 3 DIESEL 500 4 HACKED 0> <I62600 MAR 17, 2022 8:28 AM TANK LEAK ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 99 2 PREMIUM 99 3 DIESEL 99 4 HACKED 99> <I62500 MAR 17, 2022 8:28 AM TANK SUDDEN LOSS LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 50 2 PREMIUM 50 file:///C/Users/jerryr/Desktop/03-17-22%20Oaks%20-%20Monitor/Cougar%20monitor.txt[3/17/2022 11:44:19 AM] 3 DIESEL 50 4 HACKED 99> <I60800 MAR 17, 2022 8:28 AM TANK TILT TANK PRODUCT LABEL INCHES 1 UNLEADED 0.00 2 PREMIUM 0.00 3 DIESEL 0.00 4 HACKED 0.00> <I60B00 MAR 17, 2022 8:28 AM STICK HEIGHT OFFSET ENABLE STATUSDISABLED > <I60C00 MAR 17, 2022 8:28 AM TANK STICK HEIGHT OFFSETTANK PRODUCT LABEL INCHES 1 UNLEADED 0.00 2 PREMIUM 0.00 3 DIESEL 0.00 4 HACKED 0.00 >< I61200MAR 17, 2022 8:28 AM TANK MANIFOLDED PARTNERS TANK PRODUCT LABEL SIPHON MANIFOLDED TANKS LINE MANIFOLDED TANKS 1 UNLEADED NONE NONE 2 PREMIUM NONE NONE 3 DIESEL NONE NONE 4 HACKED NONE NONE >< I63600MAR 17, 2022 8:28 AM PERIODIC LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 UNLEADED 2008 file:///C/Users/jerryr/Desktop/03-17-22%20Oaks%20-%20Monitor/Cougar%20monitor.txt[3/17/2022 11:44:19 AM] 2 PREMIUM 1204 3 DIESEL 802 4 HACKED 0 >< I62A00MAR 17, 2022 8:28 AM ANNUAL LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 UNLEADED 2008 2 PREMIUM 1204 3 DIESEL 802 4 HACKED 0 >< I62C00MAR 17, 2022 8:28 AM TANK PERIODIC TEST TYPE TANK PRODUCT LABEL PERIODIC TEST TYPE 1 UNLEADED STANDARD 2 PREMIUM STANDARD 3 DIESEL STANDARD 4 HACKED STANDARD > <I62D00 MAR 17, 2022 8:28 AM TANK LEAK TEST FAIL ALARMS TANK PRODUCT LABEL 1 UNLEADED GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 2 PREMIUM GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 3 DIESEL GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 4 HACKED GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED > file:///C/Users/jerryr/Desktop/03-17-22%20Oaks%20-%20Monitor/Cougar%20monitor.txt[3/17/2022 11:44:19 AM] < I63100MAR 17, 2022 8:29 AM TANK LEAK TEST AVERAGING TANK PRODUCT LABEL ANNUAL PERIODIC 1 UNLEADED OFF OFF 2 PREMIUM OFF OFF 3 DIESEL OFF OFF 4 HACKED OFF OFF > <I63000 MAR 17, 2022 8:29 AM IN-TANK LEAK TEST NOTIFY TANK PRODUCT LABEL TANK TEST NOTIFY: 1 UNLEADED OFF 2 PREMIUM OFF 3 DIESEL OFF 4 HACKED OFF >< I63200MAR 17, 2022 8:29 AM TANK TEST SIPHON BREAK TANK PRODUCT LABEL SIPHON BREAK 1 UNLEADED OFF 2 PREMIUM OFF 3 DIESEL OFF 4 HACKED OFF > <I61000 MAR 17, 2022 8:29 AM TANK DELIVERY DELAY TANK PRODUCT LABEL 1 UNLEADED 15 2 PREMIUM 15 3 DIESEL 15 4 HACKED 1> <I63A00 MAR 17, 2022 8:29 AM file:///C/Users/jerryr/Desktop/03-17-22%20Oaks%20-%20Monitor/Cougar%20monitor.txt[3/17/2022 11:44:19 AM] LOW LEVEL PUMP THRESHOLD FOR SEQUENTIAL LINE MANIFOLD TANK PRODUCT LABEL PUMP THRESHOLD 1 UNLEADED 10.00% 2 PREMIUM 10.00% 3 DIESEL 10.00% 4 HACKED 10.00% >< I61100MAR 17, 2022 8:29 AM LEAK TEST METHOD - - - - - - - - - - - -TEST ANNUALLY: ALL TANK DEC WEEK 2 WEDSTART TIME : 2:30 AM TEST RATE :0.20 GAL/HRDURATION : 2 HOURS TST EARLY STOP:DISABLED > <I61300 MAR 17, 2022 8:29 AMCSLD PROBABLITY OF DETECTION >< I61400MAR 17, 2022 8:29 AM CSLD CLIMATE FACTOR > <I61600 MAR 17, 2022 8:29 AM TANK PRODUCT LABEL CAL UPDATE 1 UNLEADED IMMEDIATE 2 PREMIUM IMMEDIATE 3 DIESEL IMMEDIATE 4 HACKED IMMEDIATE >< I61A00MAR 17, 2022 8:29 AM file:///C/Users/jerryr/Desktop/03-17-22%20Oaks%20-%20Monitor/Cougar%20monitor.txt[3/17/2022 11:44:19 AM] IN-TANK LEAK TEST EARLY STOP TANK PRODUCT LABEL TST EARLY STOP: 1 UNLEADED DISABLED 2 PREMIUM DISABLED 3 DIESEL DISABLED 4 HACKED DISABLED >< I61B00MAR 17, 2022 8:29 AM IN-TANK LEAK GROSS TEST AUTO-CONFIRM >< I61C00MAR 17, 2022 8:29 AM CSLD REPORT ONLY >< I63400MAR 17, 2022 8:29 AM RECONCILIATION WARNING LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 0 2 PREMIUM 0 3 DIESEL 0 4 HACKED 0 >< I63500MAR 17, 2022 8:29 AM RECONCILIATION ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 UNLEADED 1 2 PREMIUM 1 3 DIESEL 1 4 HACKED 1 >< I78700MAR 17, 2022 8:29 AM > < file:///C/Users/jerryr/Desktop/03-17-22%20Oaks%20-%20Monitor/Cougar%20monitor.txt[3/17/2022 11:44:19 AM] I70200 MAR 17, 2022 8:29 AM LIQUID LABEL DEVICE LABEL 1 87 ANNULAR 2 87 STP 3 87 FILL 4 91-DIESEL ANNULAR 5 91 STP 6 91 FILL 7 DIESEL STP 8 DIESEL FILL 9 DISP 1-2 10 DISP 3-4 11 DISP 5-6 12 DISP 7-8 13 14 15 16 >< I70300MAR 17, 2022 8:29 AM LIQUID TYPE SENSOR LOCATION TYPE 1 87 ANNULAR TRI-STATE (SINGLE FLOAT) 2 87 STP TRI-STATE (SINGLE FLOAT) 3 87 FILL TRI-STATE (SINGLE FLOAT) 4 91-DIESEL ANNULAR TRI-STATE (SINGLE FLOAT) 5 91 STP TRI-STATE (SINGLE FLOAT) 6 91 FILL TRI-STATE (SINGLE FLOAT) 7 DIESEL STP TRI-STATE (SINGLE FLOAT) 8 DIESEL FILL TRI-STATE (SINGLE FLOAT) 9 DISP 1-2 TRI-STATE (SINGLE FLOAT) 10 DISP 3-4 TRI-STATE (SINGLE FLOAT) 11 DISP 5-6 TRI-STATE (SINGLE FLOAT) 12 DISP 7-8 TRI-STATE (SINGLE FLOAT) 13 TRI-STATE (SINGLE FLOAT) 14 TRI-STATE (SINGLE FLOAT) 15 TRI-STATE (SINGLE FLOAT) 16 TRI-STATE (SINGLE FLOAT) > <I70400 MAR 17, 2022 8:30 AM LIQUID CATEGORY file:///C/Users/jerryr/Desktop/03-17-22%20Oaks%20-%20Monitor/Cougar%20monitor.txt[3/17/2022 11:44:19 AM] SENSOR LOCATION CATEGORY 1 87 ANNULAR ANNULAR SPACE 2 87 STP STP SUMP 3 87 FILL OTHER SENSORS 4 91-DIESEL ANNULAR ANNULAR SPACE 5 91 STP STP SUMP 6 91 FILL OTHER SENSORS 7 DIESEL STP STP SUMP 8 DIESEL FILL OTHER SENSORS 9 DISP 1-2 DISPENSER PAN 10 DISP 3-4 DISPENSER PAN 11 DISP 5-6 DISPENSER PAN 12 DISP 7-8 DISPENSER PAN 13 OTHER SENSORS 14 OTHER SENSORS 15 OTHER SENSORS 16 OTHER SENSORS > <I80700 MAR 17, 2022 8:30 AM RELAY LABEL DEVICE LABEL 1 87 STP 2 91 STP 3 DIESEL STP 4 >< I80900MAR 17, 2022 8:30 AM RELAY ORIENTATION RELAY DESIGNATION ORIENTATION 1 87 STP NORMALLY CLOSED 2 91 STP NORMALLY CLOSED 3 DIESEL STP NORMALLY CLOSED 4 NORMALLY OPEN > <I80B00 MAR 17, 2022 8:30 AM RELAY TANK ASSIGNMENT RELAY DESIGNATION TANK 1 87 STP 1 file:///C/Users/jerryr/Desktop/03-17-22%20Oaks%20-%20Monitor/Cougar%20monitor.txt[3/17/2022 11:44:19 AM] 2 91 STP 2 3 DIESEL STP 3 4 NONE > <I80A00 MAR 17, 2022 8:30 AM RELAY TYPE RELAY DESIGNATION TYPE 1 87 STP STANDARD 2 91 STP STANDARD 3 DIESEL STP STANDARD 4 STANDARD >< I80800MAR 17, 2022 8:30 AM RELAY SETUP REPORT R 1:87 STP TYPE: STANDARD NORMALLY CLOSED TANK #: 1 LIQUID SENSOR ALMS L 1:FUEL ALARM L 2:FUEL ALARM L 9:FUEL ALARM L10:FUEL ALARM L11:FUEL ALARM L12:FUEL ALARM L 1:SENSOR OUT ALARM L 2:SENSOR OUT ALARM L 9:SENSOR OUT ALARM L10:SENSOR OUT ALARM L11:SENSOR OUT ALARM L12:SENSOR OUT ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD HOSE ALARMS ALL:FLOW COLLECT FAIL file:///C/Users/jerryr/Desktop/03-17-22%20Oaks%20-%20Monitor/Cougar%20monitor.txt[3/17/2022 11:44:19 AM] R 2:91 STP TYPE: STANDARDNORMALLY CLOSED TANK #: 2 LIQUID SENSOR ALMS L 4:FUEL ALARM L 5:FUEL ALARM L 9:FUEL ALARM L10:FUEL ALARM L11:FUEL ALARM L12:FUEL ALARM L 4:SENSOR OUT ALARM L 5:SENSOR OUT ALARM L 9:SENSOR OUT ALARM L10:SENSOR OUT ALARM L11:SENSOR OUT ALARM L12:SENSOR OUT ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD HOSE ALARMS ALL:FLOW COLLECT FAIL R 3:DIESEL STP TYPE: STANDARD NORMALLY CLOSED TANK #: 3 LIQUID SENSOR ALMS L 4:FUEL ALARM L 7:FUEL ALARM L12:FUEL ALARM L 4:SENSOR OUT ALARM L 7:SENSOR OUT ALARM L12:SENSOR OUT ALARM R 4: TYPE: STANDARDNORMALLY OPEN file:///C/Users/jerryr/Desktop/03-17-22%20Oaks%20-%20Monitor/Cougar%20monitor.txt[3/17/2022 11:44:19 AM] TANK #: NONE - NO ALARM ASSIGNMENTS - >< I79000MAR 17, 2022 8:30 AM EDIM:1 VR:349643-001-B TD:97.10.27.11.25 > <I72300 MAR 17, 2022 8:30 AM BROOKSIDE MARKET 8803 CAMINO MEDIA BAKERSFIELD CA 93311 SMARTSENSOR ASSIGNMENT DEVICE LABEL CATEGORY01 DISP 1-2 FM AIR FLOW METER 02 DISP 3-4 FM AIR FLOW METER03 DISP 5-6 FM AIR FLOW METER 04 DISP 7-8 FM AIR FLOW METER05 PRESS SENSOR VAPOR PRESSURE 06 UNKNOWN07 UNKNOWN 08 UNKNOWN09 UNKNOWN 10 UNKNOWN11 UNKNOWN 12 UNKNOWN13 UNKNOWN 14 UNKNOWN15 UNKNOWN 16 UNKNOWN17 UNKNOWN 18 UNKNOWN19 UNKNOWN 20 UNKNOWN21 UNKNOWN 22 UNKNOWN23 UNKNOWN 24 UNKNOWN25 UNKNOWN 26 UNKNOWN27 UNKNOWN 28 UNKNOWN file:///C/Users/jerryr/Desktop/03-17-22%20Oaks%20-%20Monitor/Cougar%20monitor.txt[3/17/2022 11:44:19 AM] 29 UNKNOWN 30 UNKNOWN31 UNKNOWN 32 UNKNOWN33 UNKNOWN 34 UNKNOWN35 UNKNOWN 36 UNKNOWN37 UNKNOWN 38 UNKNOWN39 UNKNOWN 40 UNKNOWN >< IV4F00MAR 17, 2022 8:30 AM BROOKSIDE MARKET 8803 CAMINO MEDIA BAKERSFIELD CA 93311 NOZZLE A/L RANGEA/L RATIO: 0.95 - 1.15 > <IV4000 MAR 17, 2022 8:30 AM BROOKSIDE MARKET 8803 CAMINO MEDIA BAKERSFIELD CA 93311 VAPOR PROCESSOR TYPE NONE >< IV4700MAR 17, 2022 8:31 AM BROOKSIDE MARKET 8803 CAMINO MEDIA BAKERSFIELD CA 93311 ASSESSMENT TIMESTART TIME: 9:00 AM TIME DELAY MINUTES: 1 > file:///C/Users/jerryr/Desktop/03-17-22%20Oaks%20-%20Monitor/Cougar%20monitor.txt[3/17/2022 11:44:19 AM] < IV5200MAR 17, 2022 8:31 AM BROOKSIDE MARKET 8803 CAMINO MEDIA BAKERSFIELD CA 93311 ACCEPT HIGH ORVR: NO > <IV4A00 MAR 17, 2022 8:31 AM BROOKSIDE MARKET 8803 CAMINO MEDIA BAKERSFIELD CA 93311 ISD HOSE TABLE HOSE FP FP AFM REL HOSE ID ID LABEL ID ID LABEL 01 01 01 01 UU BLEND3 02 02 02 01 UU BLEND3 03 03 03 02 UU BLEND3 04 04 04 02 UU BLEND3 05 05 05 03 UU BLEND3 06 06 06 03 UU BLEND3 07 07 07 04 UU BLEND3 08 08 08 04 UU BLEND3 >< IV4B00MAR 17, 2022 8:31 AM BROOKSIDE MARKET 8803 CAMINO MEDIA BAKERSFIELD CA 93311 PRODUCT/HOSE MAP TABLE FP AFID M1/H1 M2/H2 M3/H3 M4/H401 01 02/01 09/01 01/01 xx/xx 02 01 02/02 09/02 01/02 xx/xx03 02 02/03 09/03 01/03 xx/xx 04 02 02/04 09/04 01/04 xx/xx05 03 02/05 09/05 01/05 xx/xx 06 03 02/06 09/06 01/06 xx/xx07 04 02/07 09/07 01/07 xx/xx 08 04 02/08 09/08 01/08 xx/xx file:///C/Users/jerryr/Desktop/03-17-22%20Oaks%20-%20Monitor/Cougar%20monitor.txt[3/17/2022 11:44:19 AM] >< IV4900MAR 17, 2022 8:31 AM BROOKSIDE MARKET 8803 CAMINO MEDIA BAKERSFIELD CA 93311 LABEL TABLEID LABEL 01 UNASSIGNED02 BLEND3 03 REGULAR 04 MID GRADE 05 PREMIUM 06 GOLD 07 BRONZE 08 SILVER 09 BLEND2 10 BLEND4 > <IV1000 MAR 17, 2022 8:31 AM ISD VERSION: 01.06 >< I90200MAR 17, 2022 8:31 AM SOFTWARE REVISION LEVELVERSION 336.02 SOFTWARE# 346336-100-C CREATED - 21.02.13.11.53 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD/APM > <I11100 MAR 17, 2022 8:31 AM BROOKSIDE MARKET 8803 CAMINO MEDIA BAKERSFIELD CA 93311 file:///C/Users/jerryr/Desktop/03-17-22%20Oaks%20-%20Monitor/Cougar%20monitor.txt[3/17/2022 11:44:19 AM] PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME OTHER MISS VAPOR FLOW MTR CLEAR 3-11-22 3:21PM OTHER MISSING HOSE SETUP CLEAR 3-11-22 3:21PM OTHER MISS VAPOR FLOW MTR ALARM 2-13-21 8:27AM OTHER MISSING HOSE SETUP ALARM 2-13-21 8:27AM OTHER MISSING HOSE SETUP CLEAR 2-13-21 8:20AM OTHER MISS VAPOR PRES SEN CLEAR 2-13-21 8:09AM OTHER MISS VAPOR FLOW MTR CLEAR 2-13-21 8:09AM OTHER MISS VAPOR PRES SEN ALARM 2-13-21 8:05AM OTHER MISS VAPOR FLOW MTR ALARM 2-13-21 8:05AM OTHER MISSING HOSE SETUP ALARM 2-13-21 8:05AM SYSTEM BATTERY IS OFF CLEAR 2-13-21 8:00AM SYSTEM BATTERY IS OFF ALARM 2-13-21 8:00AM >< I11200MAR 17, 2022 8:31 AM BROOKSIDE MARKET 8803 CAMINO MEDIA BAKERSFIELD CA 93311 NON-PRIORITY ALARM HISTORYID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME SYSTEM PRINTER ERROR CLEAR 3-14-22 9:29AM SYSTEM PAPER OUT CLEAR 3-14-22 9:29AM SYSTEM PRINTER ERROR ALARM 3-14-22 9:29AM SYSTEM PAPER OUT ALARM 3-14-22 9:29AM > <I20600 MAR 17, 2022 8:31 AM BROOKSIDE MARKET 8803 CAMINO MEDIA BAKERSFIELD CA 93311 TANK ALARM HISTORY TANK 1 UNLEADED TANK 2 PREMIUM TANK 3 DIESEL TANK 5 file:///C/Users/jerryr/Desktop/03-17-22%20Oaks%20-%20Monitor/Cougar%20monitor.txt[3/17/2022 11:44:19 AM] TANK 6 TANK 7 TANK 8 TANK 9 TANK 10 TANK 11 TANK 12 TANK 13 TANK 14 TANK 15 TANK 16 > <I38200 MAR 17, 2022 8:31 AM >< I30200MAR 17, 2022 8:32 AM BROOKSIDE MARKET 8803 CAMINO MEDIA BAKERSFIELD CA 93311 LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 87 ANNULAR 2 87 STP 3 87 FILL 4 91-DIESEL ANNULAR 5 91 STP 6 91 FILL 7 DIESEL STP 8 DIESEL FILL 9 DISP 1-2 10 DISP 3-4 11 DISP 5-6 12 DISP 7-8 file:///C/Users/jerryr/Desktop/03-17-22%20Oaks%20-%20Monitor/Cougar%20monitor.txt[3/17/2022 11:44:19 AM] > <I31600 MAR 17, 2022 8:32 AM BROOKSIDE MARKET 8803 CAMINO MEDIA BAKERSFIELD CA 93311 SMART SENSOR ALARM HISTORY REPORT SENSOR LOCATION 1 DISP 1-2 FM 2 DISP 3-4 FM 3 DISP 5-6 FM 4 DISP 7-8 FM 5 PRESS SENSOR >< I10200MAR 17, 2022 8:32 AM BROOKSIDE MARKET 8803 CAMINO MEDIA BAKERSFIELD CA 93311 SYSTEM CONFIGURATION SLOT BOARD TYPE POWER ON RESET CURRENT 1 UNUSED 10340846 10340846 2 UNUSED 10264550 10264550 3 UNUSED 10253776 10253776 4 UNUSED 10256495 10256495 5 4 PROBE / G.T. 164181 164181 6 INTERSTITIAL BD 202863 202863 7 INTERSTITIAL BD 203964 203964 8 8SMARTSENSOR BD 39611 39611 9 UNUSED 10274437 10274437 10 RELAY BOARD 14980 14980 11 UNUSED 10267565 10267565 12 UNUSED 10251061 10251061 13 UNUSED 10247075 10247075 14 UNUSED 10248507 10248507 15 UNUSED 10252618 10252618 16 UNUSED 10257164 10257164 COMM 1 ELEC DISP INT. 101655 101655 COMM 2 SERIAL SAT BD 487411 487411 COMM 3 RS232 SERIAL BD 15042 15042 COMM 4 UNUSED 10258784 10258784 COMM 5 UNUSED 10246203 10246203 file:///C/Users/jerryr/Desktop/03-17-22%20Oaks%20-%20Monitor/Cougar%20monitor.txt[3/17/2022 11:44:19 AM] COMM 6 UNUSED 10240265 10240265 > <I90200 MAR 17, 2022 8:32 AMSOFTWARE REVISION LEVEL VERSION 336.02SOFTWARE# 346336-100-C CREATED - 21.02.13.11.53 S-MODULE# 330160-004-aSYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD/APM >