Loading...
HomeMy WebLinkAboutFire Safety 4-5-22BAKERSFIELD FIRE DEPARTMENT FIRE PREVENTION INSPECTION Prevention Services Q 2101 H Street ." Bakersfield, CA 93301 Phone: 661-326-3979 9 Fax: 661-852-2171 Wet/Dry Sprinkler System Type of Alarm System CONSTRUCTION TYPE HIGH RISEG SQ/FT OF BLD Ni 'r�, ; ... 7G El YES NO CORRECT ALL VIOLATIONS VIOLATION REQUIREMENTS CHECKED BELOW NO. C.F.C. CALIFORNIA FIRE CODE 1 Remove and safely dispose of all hazardous refuse and dry vegetation on the above premises (CFC COMBUSTIBLE WASTE / DRY VEGETATION CALIFORNIA BUILDING CODE 3 04.1.1) 2 Provide non-combustible containers with tight fitting lids for the storage of combustible waste and INSPECTOR: '^ N�, ; P -3N. F. P.A. rubbish pending its safe disposal. (CFC 304.3.2) Note: applies to containers over 40 gallons. COMBUSTIBLE STORAGE 3 Relocate combustible storage to provide at least 3 feet clearance around motor fuse box/fire door (CFC ASSOCIATION 604.3) N.E.C. 4 Relocate fire extinguisher(s) so that they will be in a conspicuous location, hanging on brackets with the Yellow - Station Copy Pink - Business Copy top to the extinguisher not more than 5 feet above the floor. (CFC 906.5 & 906.9) EXTINGUISHERS 5 Provide and install(amount) e & size ( ) ___-- approved P t P (type ) __________________ portable fire FD 2022 (Rev. 02/2020) extinguisher to be immediately accessible for use in (area) ---------- ... -------------... -- (CFC TABLE 906.3) 6 Re -charge all fire extinguishers. Fire extinguishers shall be serviced at least once each year, and/or after each use, by a person having a valid license or certificate. (CFC 906.2) 7 Provide and maintain "EXIT" sign(s) with letters 6 or more inches in height over each required exit SIGNS (door/window) to fire escape. (CFC 1013.6.1) 8 Provide and maintain appropriate numbers on a contrasting background and visible from the street to indicate the correct address of the building. (CFC 505.1) 9 Repair all cracks/holes/openin s in plaster in location . FIRE DOORS/ FIRE SEPARATIONS Plastering shall return the surface to its original fire resistive condition. (CFC 703.1) 10 Remove/repair (item & location) ------------------------------- __ _______ _____ . Self-closing doors shall be designed to close by gravity, or by the action of a mechanical device, or by an approved smoke and heat sensitive device. Self-closing doors shall have no attachments capable of preventing the operation of the closing device. (CFC 705.2.4) EXITS 11 Remove all obstruction from hallways. Maintain all means of egress free of any storage. (CFC 1031.3) 12 Provide a contrasting colored and permanently installed electric light over or near required exit (location) ------------------------------ to clearly indicate it as an exit. (CFC 10 0 8) STORAGE 13 Remove all storage and/or other obstructions from fire escape landings and stairways stair shafts. (Fire escapes/stair shafts are to be maintained free from obstructions at all times.) (CFC 1003.6) 14 Extension cords shall not be used in lieu of permanent approved wiring. Install additional approved ELECTRICAL APPLIANCES electrical outlets where needed. (CFC 604.5) 15 Remove multiple attachment cords from specific electrical convenience outlet (one plug per outlet) (CFC 604.4.2) Commercial Hood 16 Automatic Fire Extinguishing systems shall be serviced at least every 6 months CFC 904.12.5.2 17 Commercial cooking systems shall be operated and maintained in accordance with code (CFC 607) OTHER 18 Violations of Section (CFC 5608.1) & 8.44.040 (B.M.C.). AT CORRECTION DATE Co rect e viplations noted above by: LEGEND: CUSTOMER: f I 14y V il tt C.F.C. CALIFORNIA FIRE CODE ig ure) ���,�� (�. (e rN i ly, itle) Yn '�1 C.B.C. CALIFORNIA BUILDING CODE B.M.C. BAKERSFIELD MUNICIPAL CODE INSPECTOR: '^ N�, ; P -3N. F. P.A. NATIONAL FIRE PROTECTION ASSOCIATION N.E.C. NATIONAL ELECTRIC CODE White - Prevention Services Yellow - Station Copy Pink - Business Copy FD 2022 (Rev. 02/2020)