HomeMy WebLinkAbout1.8-7299 Ph 61 2 3 4 5 6 7 8 9 10
E
lug
C
W
Underground Service Alert
- - Call: TOLL FREE I
TWO WORKING DAYS BEFORE YOU DIG
u O u E ED U.S.A.
DATE:
TICKET #
BY:
CONSTRUCTION NOTE:
GAS PIPELINE UNDERGROUND WARNING TAPE TO BE INSTALLED ABOVE
GAS PIPE IN ALL TRENCHES AS SHOWN IN DETAIL BELOW.
CAUTION CAUTION
GAS LINE BURIED BELOW
GAS PIPELINE UNDERGROUND
WARNING TAPE CODE #379947.
YELLOW TAPE WITH BLACK LETTERING.
FINISH GRADE
MIN. 12"
WARNING TAPE
INSTALLATION ZONE
WARNING TAPE
GAS PIPELINE MIN. 12"
G
SUBSTRUCTURE VERIFICATION STAMP
PLEASE NOTE AND SIGN
ALL P.G.& E. ENCLOSURES AND BOXES HAVE BEEN SET TO GRADE ACCORDING TO GRADE
STAKES PROVIDED BY DEVELOPERS ENGINEER. ALL COSTS TO RELOCATE OR RE -ADJUST
BOXES AT A LATER DATE WILL BE BILLED TO THE DEVELOPER. PLEASE HAVE YOUR JOB
SUP. VERIFY THE CORRECTED GRADE OF ALL ENCLOSURES AND BOXES. AND SIGN AND
DATE DRAWING.
THANK YOU
SIGNED
DATE
PROJECT
CONDITIONS STAMP
Type(s) of Work:
X❑ New Business
❑ PG&E Maintenance
& Construction
Project Conditions:
❑X NONE APPARENT (if
project design changes, contact ADE)
or
❑ CONDITIONS APPLY:
❑ PERMITS
❑ TAILBOARD ❑ OTHER
(Provide additional information on line below)
Belinda Gursky,
BABG, 04/07/2020------
BY:
SIGNATURE,
NAME, [CORPORATE ID], DATE
D
RIMARY ELECTRIC
ECONDARY ELECTRIC
ELEPHONE
'ABLE
;TREET LIGHTS
TRENCH FOOTAGE
TRENCH IDENTIFIER
FIELD CONFLICTS
CONFLICTS TO BE MANAGED IN -THE -FIELD PER PG&E STANDARDS AND
FINAL APPROVAL FROM PG&E INSPECTOR
WET UTILITY CLEARANCES
THE MINIMUM ALLOWABLE SEPARATION BETWEEN THE EDGE OF THE JOINT
TRENCH AND THE EDGE OF ANY "WET" FACILITY TRENCH IS 3' WITH THE
PRESENCE OF A MINIMUM OF 1' OF UNDISTURBED EARTH OR THE
INSTALLATION OF A SUITABLE BARRIER.
LEGEND
G GAS
P ELECTRIC PRIMARY
S ELECTRIC SECONDARY/SERVICE
T TELEPHONE
C CABLE TV
----------- SERVICE TRENCH
-IT -IT- MAIN LINE DISTRIBUTION TRENCH
HR EXIST. GAS ONLY TRENCH (HP PQ
-IT IT- EXISTING UNDERGROUND FACILITY
-WTR WTR PROPOSED OR EXISTING DOMESTIC WATER
-SID SID PROPOSED STORM DRAIN
sWR PROPOSED SANITARY SEWER
MINIMUM COVER AND CLEARANCES
MINIMUM SEPARATION FROM
G
DUCT
T
DB
T
C
S
P
SL
MIN. COVER
G
(GAS)
-
12"
12"
12"
6"
12"
6"
30"
T
(TELEPHONE) DUCT
12"
-
1"
1"
12"
12"
12"
24"
T
(TELEPHONE) DB
12"
1"
-
1"
12"
12"
12"
24"
C
(CATV)
12"
1"
1"
-
12"
12"
12"
24"
S
(SECONDARY)
6"
12"
12"
12"
3"
3"
3"
30"
P
(PRIMARY)
12"
12"
12"
12"
3"
3"
3"
30"
SL
(STREET LIGHT)
6"
12"
12"
12"
3"
3"
3"
30"
FE
(FOREIGN ELECTRIC)
12"
12"
12"
12"
12"
12"
12"
30"
TYPICAL TYPICAL
DISTRIBUTION TRENCH SERVICE TRENCH
24" MIN. 18" MIN.
a
w
a
Q o
w
w
a o
N
w
o
T C T C
G N
3 3° 6 MIN.
P MIN. S MIN SL S G
N N
PRIMARY SECONDARY/SERVICE
SUBSTRUCTURES I)EC P
U
o
E
Q
S
O
U
L
O
SUBSTRUCTURE
QUANTITY
COMPANY
TRENCH AGENT
#5 Box
1
PG&E
APPLICANT
6"
X
X
#2 Box
11
PG&E
APPLICANT
2"
X
X
#2E Box
1
PG&E
APPLICANT
2"
X
X
PM TX
3
PG&E
APPLICANT
6"
X
X
Bellhole
2
PG&E
PG&E
X
X
JOINT TRENCH RECAP
DIST OR
SERV
TRENCH
SIZE
BACKFILL
SURFACE
FOOTAGE
o
o
TRENCH
SECTION
INDICATES SPECIFIC UTILITIES
IN TRENCH
o
w x'D'
G
T
C
S
P
L
S
X
X
24"x54"
X
X
X
46
GTC
X
X
X
X
24%54"
X
X
X
101
GPTC
X
X
X
X
X
24"x54"
X
X
X
458
GSTC
X
X
X
X
X
24"x54"
X
X
X
245
GPSTC
X
X
X
X
X
X
24"x54"
X
X
X
713
--------------------------
---- --------------------------------------------------------------------
GSTC
X
X
X
X
X
I
118%54"
1 X
I
I
IXIX
497
* GSTC
X
X
X
X
I X
1 18%42"
1 X
I
I
IXIX
675
* Service trench on private property not included in LES report
PROPOSED BELLHOLE 5'x 5'x 4'
PROPOSED PADMOUNT TRANSFORMER
PROPOSED PRIMARY BOX Sx 5'x 3'6"
PROPOSED SECONDARY BOX 17"x 30"x 26"
PROPOSED SECONDARY BOX 17"x 30"x 18"
SLASH INDICATES CHANGE IN OCCUPANCY
INDICATES TRENCH FOOTAGE & OCCUPANCY
PROPERTY LINE
-- PUBLIC UTILITY EASEMENT
LAND RIGHTS:
PG&E'S GAS DISTRIBUTION FACILITIES WILL BE INSTALLED IN
THE PRIVATE STREET. THE FINAL MAP DESIGNATES THAT THE
PRIVATE STREET IS LOT 'A'. LOT 'A' IS DESCRIBED AS A
PUBLIC UTILITY EASEMENT (PUE). PG&E'S LAND DEPT TO
REVIEW FINAL MAP'S PUE DESCRIPTION.
PG&E REP.
PHONE:
WORK SUMMARY
CJ L.J
w
z
z
*(SEE NOTE BELOW) Q
J
d d Q H U Z
TRENCH - STREET AREA:
O
•
O
O
O
EXCAVATE / TRENCH / BACKFILL
TRENCH - PRIVATE PROPERTY:
O
O
•
O
O
O
EXCAVATE / TRENCH / BACKFILL
GAS MAIN PIPE + MATERIAL **(SEE NOTE BELOW)
PROVIDE
•
O
•
O
O
O
INSTALL
•
O
•
O
O
O
GAS - HOT TIE-IN
INSTALL
•
0
0
0
0
0
ELECTRIC - CABLE + TRANSFORMER
PROVIDE
O•
0
0
0
0
INSTALL
O•
0
0
0
0
ELECTRIC - CONDUIT + TRANSFORMER PAD
PROVIDE
0
00
0
0
0
INSTALL
0
00
0
0
0
TELEPHONE - CABLE
PROVIDE
0
0
00
0
0
INSTALL
0
0
00
0
0
TELEPHONE - CONDUIT
PROVIDE
0
0
00
0
0
INSTALL
0
0
00
0
0
TELEPHONE - BOXES/PEDESTALS
PROVIDE
0
0
00
0
0
INSTALL
0
0
00
0
0
CAN - CABLE
PROVIDE
0
0
0
00
O
INSTALL
0
0
0
00
O
CAN - CONDUIT
PROVIDE
0
0
0
00
O
INSTALL
0
0
0
00
O
CAN - BOXES/PEDESTALS
PROVIDE
0
0
0
00
O
INSTALL
0
0
0
00
O
*NOTE:
PG&E TO EXCAVATE & BACKFILL THE TIE-IN AND PURGE BELLHOLES.
APPLICANT TO PROVIDE ALL OTHER TRENCH, EXCAVATION & BACKFILL
**NOTE:
APPLICANT TO PROVIDE/INSTALL GAS MAIN + SVC STUB PIPE.
PG&E TO PROVIDE/INSTALL GAS SVC COMPLETION PIPE IN APPLICANT
SUPPLIED TRENCH.
J UAN M EJ IA
661-398-5899
TRENCH SECTION - 60' R/W
INTERIOR STREET
10• 5' 7'
SIDEWALK
1' LWDSCAPE INTERIOR STREET
iRONSGORMER �
0
a
ALL FIELD CHANGES REQUIRE PRIOR APPROVAL FROM:
UTILITY
CONTACT
TELEPHONE
PG&E GAS
BELINDA GURSKY
(559) 347-5038
PG&E ELECTRIC
JOSE RAMOS
(559) 263-5671
AT&T
DALE YOUNGBLOOD
(661) 631-3330
CHARTER COMM
RYAN LINDSAY
(661) 395-3324
M
I
M
I
M
I
M
I
M
I
ri
Z
N
O
N
COI
r
�
N
CD
W
LC-)
C_O
[Il
[Il
CJ
LC-)
a
z
a
z
nq
o'o
CD
v�
�LD
Uzwo
0
r4D
z
w �
ociOj
w
I I
w
w
w
w
Q
�
z
QCT
Q ❑
NOTES FOR APPLICANT TRENCH
cn
1. CALL "USA" 2 WORKING DAYS BEFORE EXCAVATING. UNDERGROUND SERVICE ALERT CALL TOLL FREE 811.
z
rr-
2. SPECIFIC CONDITIONS REQUIRED BY PG&E FOR JOINT TRENCH WORK ARE OUTLINED IN PG&E'S UTILITY OPERATIONS
CD
00
STANDARD S5453.
<
w
3. BACKFILL MATERIAL REQUIREMENTS ARE DETAILED IN U.O. STANDARD S5453, EXHIBIT "B".
w
4. PG&E INSPECTOR TO APPROVE ALL EXCAVATIONS AND TRENCHES (LOCATION AND BACKFILL MATERIAL) PRIOR TO
BACKFILLING.
5. TRENCHING AGENT TO DISPOSE OF ALL SPOIL.
N
X
LU
6. MINIMUM COVER FROM FINAL GRADE REQUIRED FOR ALL FACILITIES IN THE STREET AREA.
w
U
o0
N
7. GROUND TO BE WITHIN .2' OF FINISH GRADE PRIOR TO TRENCHING.
8. SOME TRENCH CORNERS MAY REQUIRE SHAVING TO ACCOMMODATE CONDUIT BENDING RADIUS.
�e
N
o
o
z
N
F= F_
9. CUSTOMER IS RESPONSIBLE FOR OBTAINING NECESSARY ENCROACHMENT PERMITS AS REQUIRED BY LOCAL CITY,
J
Z
COUNTY OR STATE AUTHORITIES.
3
3
CS
NA
0
10. CONTRACTOR IS RESPONSIBLE FOR CROSSING EXISTING WATER, SEWER AND STORM DRAIN LINES, EITHER UNDER
OR OVER AS REQUIRED TO MEET PG&E COVER AND CLEARANCE REQUIREMENTS. REFER TO U.O. STANDARD S5453.
N
11. THE CONTRACTOR WILL BE REQUIRED TO REMOVE AND REPLACE TRENCH SPOIL WITH 100% SELECT BACKFILL AS
U
REQUIRED BY PG&E SPECIFICATIONS AND ANY LOCAL CITY, COUNTY OR STATE REQUIREMENTS.
12. THE CONTRACTOR WILL BE REQUIRED TO PLACE TEMPORARY AND/OR PERMANENT PAVING IN ACCORDANCE WITH
z
ANY LOCAL CITY OR STATE REQUIREMENTS.
w
13. THE APPLICANT/CONTRACTOR WILL ACCEPT RESPONSIBILITY OF MAINTENANCE OF THE TRENCH (E.G. COMPACTION,
PAVING, ETC.) FOR A PERIOD OF TWO (2) YEARS OR AS SPECIFIED IN THE PERMIT, WHICHEVER IS LONGER.
Z
14. THE LOCATION OF ALL EXISTING OR NEWLY INSTALLED WATER, SEWER AND STORM DRAINS OR OTHER LINES,
o
SHALL BE DETERMINED BY THE CONTRACTOR. THE CONTRACTOR SHALL NOT RELY ON PG&E TO LOCATE THESE
-
FACILITIES. (PG&E WILL LOCATE PG&E FACILITIES UPON PROPER USA NOTIFICATION. CALL USA AT 811.
I
15. SPLICE BOXES OR EQUIPMENT TO BE INSTALLED NO CLOSER THAN 1' LATERALLY OVER GAS FACILITIES.
0
16. CUSTOMER WILL BE REQUIRED TO INSTALL APPROVED SHORING FOR ANY TRENCH ACCORDING TO STATE
EXCAVATION SAFETY STANDARDS.
17. MAINTAIN 2 FEET BETWEEN SPOIL BANK AND EDGE OF TRENCH.
18. CUSTOMER TO BACKFILL AND TAMP SOIL AROUND RISER.
NOTES FOR APPLICANT INSTALL
1.
APPLICANT TO PROVIDE AND INSTALL ANY PROTECTION EQUIPMENT (BARRIER POSTS, FENCES, ETC.) REQUIRED BY
PG&E.
2.
PG&E MUST RECEIVE THE INSPECTION CLEARANCE FROM THE CITY/COUNTY BUILDING INSPECTION DEPARTMENT
PRIOR TO THE GAS METER INSTALLATION.
3.
FOR METER INSTALLATION CONTACT PG&E REPRESENTATIVE OR CUSTOMER CONTACT CENTER AT
w
o
1-800-743-5000.3.
� ~m
O o J
w
Y
4.
REFER TO GAS STANDARDS A-90 AND A-90.3 FOR TYPICAL DIRECT BURIAL PLASTIC GAS MAIN AND SERVICE
N
INSTALLATION.
o
U Q w
5.
REFER TO GAS STANDARDS A-90 FOR TYPICAL PLASTIC GAS MAIN AND SERVICE INSERT.
CD w
C-)
6.
REFER TO GAS STANDARDS A-90.2 AND 0-13.1 FOR TYPICAL ANODE AND LOCATING WIRE INSTALLATION ON DIRECT
w m
N`
BURIAL PLASTIC GAS MAIN AND SERVICES.
w
7.
REFER TO GAS STANDARDS A-91 FOR TYPICAL GAS SERVICE RISER INSTALLATION.
z
~
8.
REFER TO GAS STANDARD A-34 FOR TEST CRITERIA ON GAS MAIN AND SERVICES.
C)
125
D
9.
REFER TO GAS STANDARD A-93.1, B-90, B-90.1 AND B91.1 FOR TYPICAL MECHANICAL FITTINGS CONNECTION.
10.
PACIFIC GAS AND ELECTRIC TO PERFORM ALL HOT TIE-INS AND PURGING OF GAS PIPING PER GAS STANDARD
A-38.
11.
ALL FIELD CHANGES REQUIRE PRIOR APPROVAL PER TD-4014P-05.
6 5 4 3 2 1 INCH 0
1 2 3 4 5 6 7 8 9 10
0
0
w I csrc
3
I
T573242 1
hone b
I
2 FI
PUE
I� ,7
z
�I 1
C
MING AVENUE
W W W W W W -- ---
I I I I I I I I
I I I I I I I I
3 O
5 6 7 8 9 10 11 12 13
\ wwu Rm Ruin GOIFIEI
Ky
T219836
—1 \ \ GPTC ^� GPSTC GPSTC IOWA M G P9 C — — — GPTC IL
HOLE FOR
)W
\X '_ 80 —� 158 23 — — r, —
/1T NI INI INI --- N Am X�'
1T 1T 1T 1T 1T 1T 1T 1T 1T 1T JT — — — —
IT IT IT -- IT JT IT
PCP 5 ---J ON. JIM 1RENCN PY 361�BD (2019)
1 I
co TO DIME R LOCATE, INTERCEPT AND
o� &jM TE* B IHIYF IXTEND MISTING 485'
BARBON BECK AVENUE I M ,-4°CONDUIT TONEW
SWR I R SWR SWR SWR PDLLD�
(PRIVATE STREET)
W 4— W I — W W -- W tn
—
_- J
I
1 14 Q
�^
a w 2 �
o Q
25 26 27 w w r2GSrC -- -
� a I
o > 0
\ I U
-
I
� 10' I
22 21 20 PUE r 16
\k
I3 X TRAMMAONNVSBgXIINB cu
^
1 OI'iRV14,169MIfElOOBOPERA7L$Ai 7A7151G � � r
PCdE R�IIWPM A BANOBY PHM iO BE ON 80E
1 r� `tiO MHBf1FA WPM
Itl®N, hnft eC118WIIHN POF
L PiE EDGE OF➢ERPEIINE h
A
I!
24
w w
w LU
N VI
NI
Lu
1'
>
L
w a
!�
23
N
\ \ \ \ I LEIGHFIELD WAY
"R—'— (PRIVATE STREET) -SW"-
\ \ \ PRIVATE STREET I SDI
IS LOT'A' i GPSTC ;
203
\ \JT IT T
ITPOCKET
PARK \ \ \
\ \\ I I
EPR 21kY IN 1-2' DUCT — \ \ I 19
PY:31393621 PEMBERLEY PASSAGE AVENUE \ 3
1-1/DA EPR 21W IN
1_-2' DUCT 525'
sa
283136
18
/ I
\ ` I
/ 14
i \
/
15 \
LEGEND
G
GAS
P
ELECTRIC
PRIMARY
S
ELECTRIC
SECONDARY/SERVICE
T
TELEPHONE
C
CABLE TV
-----------
SERVICE TRENCH
—TT —TT—
MAIN LINE
DISTRIBUTION TRENCH
HP
EXIST. GAS ONLY TRENCH (HP PQ
,T TT
EXISTING UNDERGROUND FACILITY
—WTR WTR
PROPOSED
OR EXISTING DOMESTIC WATER
So so
PROPOSED
STORM DRAIN
sWR
PROPOSED
SANITARY SEWER
r—�
PROPOSED
BELLHOLE 5'x 5'x 4'
L_J
PROPOSED
PADMOUNT TRANSFORMER
IL 5 ]
PROPOSED
PRIMARY BOX 3'x 5'x 3'6"
1'2Ej
PROPOSED
SECONDARY BOX 17"x 30"x 26"
11 2
PROPOSED
SECONDARY BOX 17"x 30"x 18')
/
SLASH INDICATES
CHANGE IN OCCUPANCY
cPsrc�
XXX'
INDICATES
TRENCH FOOTAGE & OCCUPANCY
PROPERTY LINE
—
——
PUBLIC UTILITY EASEMENT
TRENCH SECTION - 60' R/W
INTERIOR STREET
10' 5' 7'
SIDEWALK
1' LANDSCAPE INTERIOR STREET
7IiAN5FORMFR m
................. .
==�-1 I I II1 I I _=1 I I=1 I -III
I
GAS PURGE POINTS
GAS FACILITIES WILL BE PURGED PER GDS A-38. POTENTIAL PURGE
CONTROL POINTS (PCP) AND POTENTIAL PURGE POINTS (PP) WILL
BE LABELED ON THE GAS DESIGN FOR PLANNING PURPOSES.
ACTUAL PCP AND PP LOCATIONS WILL BE INCLUDED ON THE GAS
CLEARANCE AND MAY BE DIFFERENT.
POTENTIAL PURGE CONTROL POINTS PCP
POTENTIAL PURGE POINTS PP
LAND RIGHTS:
PG&E'S GAS DISTRIBUTION FACILITIES WILL BE INSTALLED IN
THE PRIVATE STREET. THE FINAL MAP DESIGNATES THAT THE
PRIVATE STREET IS LOT 'A'. LOT 'A' IS DESCRIBED AS A
PUBLIC UTILITY EASEMENT (PUE). PG&E'S LAND DEPT TO
REVIEW FINAL MAP'S PUE DESCRIPTION.
6 5 4 3 2
n
LU
w
ti N
g sZ
z En
F
E
m W �
3 Z U F+l
N
0
Y
U
0
w
O
N
Z
O
(n
o w
0
w
�
o
�
�
J
m
o
cV
i
o
o
U
w
�
w
co
¢
C
_
==N
_��
z
=
w
�
m
cV
~
I
LLJ
�Q
z
rr
c
�
�
z
0