Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
3800 Easton Drive
SENTVIAUSMAILANDELECTRONICMAIL April25,2022 Applicant PDAInc. PaulDhanens 133022ndStreet,Suite100 Bakersfield,CA93301 PropertyOwner BARC 4500CaliforniaAvenue Bakersfield,CA93309 RE:NoticeofDecisionSitePlanReview(ProjectNo.220150)(Ward2) DearMr.Dhanens: Theplansforconstructionofa5,475squarefootautomotiveservicebuildingwithautomotivefleetparkingintheM1 (LightManufacturingZone)districtlocatedat3800EastonDrivehavebeenreviewedbytheSitePlanReviewCommittee anditemsrequiringyourattentionareattached. Oncethecorrectionsnotedintheattachedsiteplancompliancelisthavebeenmade,theproposalwillmeetthe minimumrequiredcodes,policiesandstandardsfordevelopmentasadoptedbytheBakersfieldCityCouncil.Specific itemshavebeenidentified(seeattachedSitePlanComplianceList)thatyouneedtoresolvebeforeyoucanobtaina buildingpermitorbeallowedoccupancy.Theseitemsmayincludechangesoradditionsthatneedtobeshownonthe finalbuildingplans,alertyoutospecificfees,and/orarecommentsthatwillhelpyouincomplyingwiththeĭźƷǤƭ developmentstandards.Eachitemwillnotewhenitistobecompletedandtheyhavebeengroupedbydepartment sothatyouknowwhomtocontactifyouhavequestions. Yournextstepistoeitherapplyfornecessarybuildingpermitstoconstructyourproject,orbeginyourbusiness finalbuildingplanstotheBuildingDivision.TheSite activitiesdependingontherequestsubmitted.Youmustsubmit PlanReviewCommitteewillreviewthesefinalplanswhilebuildingplancheckoccurstoensurethatyousatisfythe itemsintheSitePlanComplianceList.Pleasereadthemcarefully.Failuretosatisfyanitemmaydelayyourobtaining abuildingpermitorcommencingyourproject. AfterconstructionofyourprojectbutbeforetheCitycanallowoccupancy,theBuildingDivisionmustinspectthe developmenttofindifitcomplieswiththeapprovedplans,andanyotherrelevantpermitsandcodes.Ifyouhave satisfiedalloftherequirements,theBuildingDirectorwillissueacertificateofoccupancy;ifnot,theareainspectorwill giveyouacorrectionnotice.Onceyouhavemadeallofthecorrections,theBuildingDirectorcanissueacertificateof occupancy.YoumaynotoccupyadevelopmentuntiltheBuildingDirectorhasissuedacertificateofoccupancy. INDEMNIFICATIONCONDITION InconsiderationbytheCityofBakersfieldforlanduseentitlements,includingbutnotlimitedtorelatedenvironmental approvalsrelatedtoorarisingfromthisproject,theapplicant,and/orpropertyownerand/orsubdividerΛͻ!ƦƦƌźĭğƓƷͼ herein)agreestoindemnify,defend,andholdharmlesstheCityofBakersfield,itsofficers,agents,employees, departments,commissionersandboardsΛͻ/źƷǤͼherein)againstanyandallliability,claims,actions,causesofactions ordemandswhatsoeveragainstthem,oranyofthem,beforeadministrativeorjudicialtribunalsofanykind limitationanyCEQA whatsoever,inanywayarisingfrom,thetermsandprovisionsofthisapplication,includingwithout approvaloranyrelateddevelopmentapprovalsorconditionswhetherimposedbytheCity,ornot,exceptfor/źƷǤƭsole activenegligenceorwillfulmisconduct. ThisindemnificationconditiondoesnotpreventtheApplicantfromchallenginganydecisionbytheCityrelatedtothis thisconditionapplyregardlessofwhetheranyotherpermitsorentitlementsareissued. projectandtheobligationsof TheCitywillpromptlynotifyApplicantofanysuchclaim,action,orproceeding,failingunderthisconditionwithinthirty (30)daysofactuallyreceivingsuchclaim.TheCity,initssolediscretion,shallbeallowedtochoosetheattorneyor outsidelawfirmtodefendtheCityatthesolecostandexpenseoftheApplicantandtheCityisnotobligatedtouseany lawfirmorattorneychosenbyanotherentityorparty. REVISIONSTOTHEAPPROVEDPLAN Anytimeaftersiteplanapprovalbutbeforetheapprovalexpires,youmaysubmitrevisionstotheplan.Wewilltreat theserevisionsasanewsiteplanapplicationsubjecttoanewreviewandrequiredfees.ThePlanningDirectorcanonly approveminorchangestotheoriginalplanwithoutanewapplicationiftheyarenecessarytomeetacondition, mitigation,orresultfromphysicalobstaclesorothercomparableconstraints(SeeSection17.08.080.c.3oftheZoning Ordinance). EXPIRATIONOFPLANS ThissiteplanexpiresonApril24,2024(2yearsfromthedecisiondate),unlessbuildingpermitshavebeenissued,or wheretheusehascommencedonprojectsnotrequiringabuildingpermit.Theprojectmustbecompletedwithin5 yearsfromthedecisiondate.Ifthepropertyisrezoned,siteplanapprovalwillexpireupontheeffectivedateforthe rezoningunlesstheuseispermittedinthenewzone. theexpirationdateuptoone(1)yearifyouresubmitnewplansforcheckagainst ThePlanningDirectormayextend thecoderequirementsineffectatthattimeandincludeawrittenrequestfortheextension.Wemustreceivethis request before expirationoftheprojectapproval.Wewillnotrequireafeeforthisextensionrequest;however, changestotheplansoriginallyapprovedforpurposesotherthancoderequirementsshallbesubjecttoanewsiteplan review,includingpaymentofallrequiredfees(SeeSection17.08.080.DoftheZoningOrdinance). ENVIRONMENTALDETERMINATION theCaliforniaEnvironmentalQualityAct Thissiteplanreviewhasbeenfoundtobeexemptfromtheprovisionsof (CEQA)accordingtoSection15332.Thisprojectisexemptbecauseitisaninfilldevelopmentthatisconsistentwiththe generalplanandzoningregulations,iswithinanareapredominantlydevelopedwithurbanuses,isnotidentifiedas criticalhabitatforendangeredorthreatenedspecies,willnotsignificantlyaffecttrafficnoise,airorwaterquality,and willbeadequatelyservedbyappropriateutilitiesandpublicservices.ANoticeofExemptionhasbeenpreparedandis availableforreviewatthePlanningDivision. SPR220150Page|2of15 APPEAL Anypersonmayappealthisdecision.Anappealislimitedtowhetherornotanadopteddevelopmentstandard, zoningregulation,mitigation,orpolicyappliedornotappliedtotheproject,wasdoneconsistentwiththe authoritygrantedbycityordinancesortheCaliforniaEnvironmentalQualityAct(CEQA).Theappealmustbein ingtheprecisebasisorissueasnoted,mustincludetheappropriatefilingfee,andmustbefiledwithin writingstat 10days ofthedecisiondatetotheCityofBakersfieldPlanningCommission(c/oBakersfieldPlanningDirector, 1715ChesterAvenue,Bakersfield,CA93301).ThePlanningCommissionwillholdapublichearingontheappeal andtheirdecisionwillbefinalunlesstheirdecisionisappealedtotheCityCouncil. Siteplanapprovalisbasedonthestatementsmadeintheapplicationandtheplansyousubmitted.Anyerrorsor omissionsontheseplanscouldalterthecompliancelistand/orvoidthisdecision.Ifyouhavequestionsabout anyoftheitemsnotedintheSitePlanComplianceList,youmustspeaktothecontactpersonrepresentingthe departmentrequiringthatitem. Correspondencewillcontinuetobesenttotheapplicantonrecord.Shouldtheapplicantchange,itistheproperty ƚǞƓĻƩƭresponsibilitytoupdatethecontactinformationwiththePlanningDivision.Ifyouhaveotherquestions regardinggeneralinformationaboutthesiteplanreviewprocess,pleasecontactthePlanningDivisionat(661) 3263733. DECISIONDATE:April25,2022 Sincerely, LindaMitchell PrincipalPlanner 9ƓĭƌƚƭǒƩĻ cc:AllInterestedAgenciesΑForyourrecords. S:\\CounterOperations\\01_SPR\\2022\\220150_3800EastonDrive_AutoService\\SPRLtr.docx SPR220150Page|3of15 CONDITIONSANDORDINANCECOMPLIANCE Thefollowingarespecificitemsthatyouneedtoresolvebeforeyoucanobtainabuildingpermitorbeallowed occupancy.Theseitemsincludeconditionsand/ormitigationrequiredbyprevioussiteentitlementapprovals (thesewillbespecificallynoted),changesoradditionsthatneedtobeshownonthefinalbuildingplans,alert youtospecificfees,andotherconditionsforyourprojecttosatisfythe/źƷǤƭdevelopmentstandards. Theitemslistedbelowwillusuallyneedtobeshownonthefinalbuildingplansorcompletedbeforeabuilding permitisissued.Aspartofthebuildingpermitsubmittal,identifythelocationofyourresponsebyusingthe !tt\[L/!b{RESPONSE lineprovideddirectlybelowtheitem(example:sheetnumber,detail,etc.). A.DEVELOPMENTSERVICESBUILDING(1715ChesterAvenue) (StaffcontactOscarFuentes;6613263676orOFuentes@bakersfieldcity.us) 1.PriortoreviewofimprovementplansbytheCity,thedevelopershallsubmitagradingplanfor theproposedsitetobereviewedandapprovedbytheCityEngineerandBuildingOfficial (BakersfieldMunicipalCodeSection16.44.010).Withthegradingplan,iftheprojectissubjectto theprovisionsoftheNationalPollutantDischargeEliminationSystem(NPDES),aNoticeofIntent (NOI)tocomplywiththetermsoftheGeneralPermittoDischargeStormWaterAssociatedwith ConstructionActivity(WQOrderNo.9908DWQ)mustbefiledwiththeStateWaterResources ControlBoardinSacramentobeforethebeginningofanyconstructionactivity.Compliancewith thegeneralpermitrequiresthataStormWaterPollutionPreventionPlan(SWPPP)beprepared, continuouslycarriedout,andalwaysbeavailableforpublicinspectionduringnormalconstruction hours. !tt\[L/!b{RESPONSE:__________________________________________________________ 2.Agradingpermitisrequiredpriortofinalplanapproval.Thedevelopershallsubmitfour(4)copies ofgradingplansandtwo(2)copiesofthepreliminarysoilsreporttotheBuildingDivision.Afinal soilsreportshallalsobesubmittedtotheBuildingDivisionbeforetheycanissueabuildingpermit. Pleasenotethatgradingplansmustbeconsistentwiththefinalbuildingsiteplansandlandscaping plans.BuildingpermitswillnotbeissueduntilthegradingpermitisapprovedbytheBuilding Division,PlanningDivision(HCP),andPublicWorksDepartment. !tt\[L/!b{RESPONSE:__________________________________________________________ 3.Showonthefinalbuildingplanpedestrianaccessfromthepublicwayandaccessibleparking. Privatestreetsarenotthepublicway. !tt\[L/!b{RESPONSE:__________________________________________________________ 4.Thedevelopershallincludefireresistivewallconstructiondetailswiththefinalbuildingplansfor allexteriorwallsofanybuildingthatiswithinthedistanceassetforthinTable602oftheCalifornia BuildingCode. SPR220150Page|4of15 !tt\[L/!b{RESPONSE:__________________________________________________________ 5.Includewithorshowonthefinalbuildingplansinformationnecessarytoverifythattheproject complieswithallaccessibilityrequirementsofTitle24oftheCaliforniaBuildingCode. !tt\[L/!b{RESPONSE:__________________________________________________________ 6.Buildingsorstructuresshallrequireinstallationofanautomaticfiresprinklersystemwhere requiredbycurrentCaliforniaBuildingCodeandCityordinance. !tt\[L/!b{RESPONSE:__________________________________________________________ 7.TheBuildingDivisionwillcalculateandcollecttheappropriateschooldistrictimpactfeeatthe timetheyissueabuildingpermit. !tt\[L/!b{RESPONSE:__________________________________________________________ 8.FinalBuildingplansshallshowpedestrianaccesspathwaysoreasementsforpersonswith disabilitiesfrompublicrightsofwaysthatconnecttoallaccessiblebuildings,facilities,elements, andspacesinaccordancewiththeCaliforniaBuildingCode.Thesepedestrianaccesswaysshall notbeparalleltovehicularlanesunlessseparatedbycurbsorrailings. !tt\[L/!b{RESPONSE:__________________________________________________________ 9.Priortograntingoccupancy,theBuildingDivisionwillverifythatawatermeterservingthe developmentisinplace.Therefore,itisrecommendedthatthedevelopercontacttheapplicable waterpurveyortoinquireabouttheirprocessforobtainingwaterserviceforthedevelopmentas soonaspossible.Todeterminewhothewaterpurveyorforthedevelopmentis,youmaycontact theCityofBakersfieldWaterResourcesDepartment(1000BuenaVistaRoad,Bakersfield,CA, phone:6613263715). !tt\[L/!b{RESPONSE:__________________________________________________________ 10.Showonthefinalbuildingplan,electricvehiclesupplyequipmenttofacilitatefutureinstallation asrequiredbytheCaliforniaGreenCode. !tt\[L/!b{RESPONSE:__________________________________________________________ SPR220150Page|5of15 B.DEVELOPMENTSERVICESPLANNING(1715ChesterAvenue) (StaffContact:VeronicaMartinezΑ6613263733orvmartinez@bakersfieldcity.us) 1.Theminimumparkingrequiredforthisprojecthasbeencomputedbasedonuseandshallbeas follows: ProposedSquareParkingRequired UseFootage(SF)RatioParking Office3691space/300SF1 AutoRepair5,1061space/500SF10 ____________________________________________________________________________ TotalRequiredParking:11spaces (Note:0parkingspacesareshownontheproposedsiteplan.Byordinance,compactandtandem spacescannotbecountedtowardsmeetingminimumparkingrequirements.Forcommercial developmentcontainingamultitenantpad,anychangeinusewhere50percentormoreofthe padrequiresadditionalparkingpursuanttoBakersfieldMunicipalSection17.58.110,thePlanning Directormayrequireparkingcommensuratewiththenewuse.) a. Showalltheparkingspacesandidentifythecountbyaisle/section. !tt\[L/!b{RESPONSE:__________________________________________________________ 2.Minimumparkingstalldimensionsshallbe9feetwideby18feetlongandshallbedesigned accordingtostandardsestablishedbytheTrafficEngineer.Vehiclesmayhangoverlandscape feetprovidedrequiredsetbacksalongstreetfrontagesaremaintained, areasnomorethan21/2 andtreesandshrubsareprotectedfromvehicles. !tt\[L/!b{RESPONSE:__________________________________________________________ 3.Lightingisrequiredforallparkinglots,exceptresidentiallotswithfourunitsorless(Section 17.58.060.A.).Illuminationshallbeevenlydistributedacrosstheparkingareawithlightfixtures designedandarrangedsothatlightisdirecteddownwardandisreflectedawayfromadjacent propertiesandstreets.Useofglareshieldsorbafflesmayberequiredforglarereductionor controlofbacklight.Nolightpoles,standardsandfixtures,includingbasesorpedestals,shall exceedaheightof40feetabovegrade.However,lightstandardsplacedlessthan50feetfrom residentiallyzonedordesignatedproperty,orfromexistingresidentialdevelopment,shallnot exceedaheightof15feet.Thefinalbuildingplansshallincludeapictureordiagramofthelight fixturesbeingusedandshowhowlightwillbedirectedontotheparkingarea. (Note:Staffcanrequireadditionaladjustmentstoinstalledlightingafteroccupancytoresolve glareorotherlightingproblemsiftheynegativelyaffectadjacentproperties.) !tt\[L/!b{RESPONSE:__________________________________________________________ SPR220150Page|6of15 4.Becauseparkingand/oraccessisbeingsharedwithadjacentproperties,thedevelopershallfile withthePlanningDivisionbeforeanybuildingpermitsareissuedacopyofarecordedmap, CC&Rs,orotherinstrumentthatensuresthatdriveaisles,parking,andaccessislegallysharedin commonwithadjoiningproperties asdepictedonthesiteplanforthelifeoftheproject. !tt\[L/!b{RESPONSE:__________________________________________________________ 5.Thedevelopershallincludeafinallandscapeplanwitheachsetofthebuildingplanssubmittedto theBuildingDivision.BuildingpermitswillnotbeissueduntilthePlanningDivisionhasapproved thefinallandscapeplanforconsistencywithapprovedsiteplansandminimumordinance standards.PleaserefertothelandscapingrequirementsinChapter17.61.Landscapeplansshall include,butarenotlimitedto,dataon:gallon/boxsize,spacing,species(referenceapproved parkinglottreelist),ratioofdeciduousvs.evergreen,shadecalculations,groundcover calculations,etc. (Note1:Atthetimeafinalsiteinspectionisconducted,itisexpectedthatplantswillmatchthe speciesidentifiedandbeinstalledinthelocationsconsistentwiththeapprovedlandscapeplan. ChangesmadewithoutpriorapprovalofthePlanningstaffmayresultintheremovaland/or relocationofinstalledplantmaterialsanddelaysinobtainingbuildingoccupancy.) (Note2:NomaturelandscapingshallberemovedwithoutpriorapprovalbythePlanning Director.) a. Showandidentifytheminimum8footwidelandscapeareaalongthestreetfrontage(Section 17.61.030.E). b. Provideaminimumrationofonetreeper20linearfeetalongthestreetfrontageandidentify thespeciestype.Aspeciesmixof30percentevergreenand70percentdeciduousshallbe maintained(Section17.61.030.F). c. Provideaminimumratioofonetreeforeachsixparkingspacesandachievetheminimum shadingrequirementsasidentifiedinSection17.61.030.H).Ofthetotalnumberoftrees requiredintheparkingareafortheentireproject,aminimumof30percentshallbeevergreen species(Section17.61.030.J). d. Ifapplicable,provideaminimumofonetreeper50linearfeetbuildingfrontagewherethe ĬǒźƌķźƓŭƭmainentrancefacesaparkinglot(Section17.61.030.I). e. Uponapprovalofthefinallandscapeplan,adigitalcopyshallbesubmittedtothePlanning staffcontactlistedabove.) !tt\[L/!b{RESPONSE:__________________________________________________________ 6.Ourrecordsshowthattheprojectiscontainedonmorethanoneparcel.Becausebuilding setbackscannotbemetbasedonthedesignlayout,aparcellinebisectsabuilding,and/orparking forresidentialuseisnotonthesamesiteastheproject(Section17.58.020.B.oftheBakersfield MunicipalCode),aparcelmergerorlotlineadjustmentapplicationremovingorrelocating propertylinesshallbesubmittedtothePlanningDivisionbeforebuildingpermitscanbeissued. SPR220150Page|7of15 Recordationofthemapshalloccurbeforefinalbuildingorsiteoccupancycanbegranted.Ifour recordsareinerror,pleaseprovideacopyoftheparcelmap,subdivisionmap,orcertificateof complianceshowingtheapprovedpropertylines. (Note:An!ƭƭĻƭƭƚƩƭmapisnotacceptablesinceitisonlyfortaxpurposesanddoesnotverify legalparcelstatus.) !tt\[L/!b{RESPONSE:__________________________________________________________ 7.Businessidentificationsignsare neitherconsiderednorapproved underthisreview(e.g.,wall, monument,pylon,etc.).AseparatesignpermitreviewedbythePlanningandBuildingDivisions andissuedbytheBuildingDivision,isrequiredforallnewsigns,includingfutureuseand constructionsigns. (Note:SignsmustcomplywiththeSignOrdinance;Chapter17.60oftheBakersfieldMunicipal Code.ReviewthisChapteraspartofduediligence.) !tt\[L/!b{RESPONSE:__________________________________________________________ 8.Priortoreceivingfinalbuildingorsiteoccupancy,youmustcontactthePlanningDivision(staff contactnotedabove)forfinalinspectionandapprovalofthelandscaping,parkinglot,lightingand otherrelatedsiteimprovements.Inspectionswillnotbeconducteduntilallrequireditemshave beeninstalled.AnydeviationsfromtheapprovedplanswithoutpriorapprovalfromthePlanning Divisionmayresultinreconstructionanddelaysinobtainingabuildingorsiteoccupancy. !tt\[L/!b{RESPONSE:__________________________________________________________ C.FIREDEPARTMENT(2101HStreet) (StaffcontactErnieMedina;6613263682orEMedina@bakersfieldfire.us) 1.Showonthefinalbuildingplansthefollowingitems: a.Allfirehydrants,bothoffsite(nearesttosite)andonsite.LƓĭƌǒķĻŅƌƚǞķğƷğƚƓğƌƌ ŷǤķƩğƓƷƭ͵Hydrantsshallbeingoodworkingconditionandaresubjecttotestingfor verification.Fireflowrequirementsmustbemetpriortoconstructioncommencingon theprojectsite.Pleaseprovidetwo(2)setsofthewaterplansstampedbyalicensed RegisteredCivilEngineertotheFireDepartmentandtwo(2)setstotheWaterResources Department(1000BuenaVistaRoad,Bakersfield,CA.93311;6613263715). (Note:Show:1)distancetothenearesthydrant;and2)distancefromthathydranttothe farthestpointoftheprojectsite.) b.Projectaddress,includingsuitenumberifapplicable.Iftheprojectiswithinashopping orbusinesscenter,notethenameandaddressofthecenter. SPR220150Page|8of15 c.Nameandphonenumberoftheappropriatecontactperson. !tt\[L/!b{RESPONSE:__________________________________________________________ 2.Wherefireapparatusaccessroadsorawatersupplyforfireprotectionarerequiredtobe installed,suchprotectionshallbeinstalledandmadeserviceablepriortoandduringthetimeof construction. !tt\[L/!b{RESPONSE:__________________________________________________________ 3.Facilities,buildingsorportionsofbuildingshereafterconstructedshallbeaccessibletofire departmentapparatusbywayofan ğƦƦƩƚǝĻķŅźƩĻğƦƦğƩğƷǒƭğĭĭĻƭƭƩƚğķ withanasphalt,concrete orotherdrivingsurfaceapprovedbythefirechief.Mustbecapableofsupportingtheimposed loadoffireapparatus weighingatleast75,000poundsandshallbesurfacedwiththefirstliftof asphaltastoprovideallweatherdrivingcapabilities.Allaccess(Permanentandtemporary)to andaroundanybuildingunderconstructionmustbealeast20feetwide(26feetwidewhere buildingheightexceeds30feet),withanoverheadclearanceof13feet6inches,andcontainno obstruction.Thefireapparatusaccessroadshallextendtowithin150feetofallportionsofthe facilityandallportionsoftheexteriorwallsofthefirststoryofthebuildingasmeasuredbyan approvedroutearoundtheexteriorofthebuildingorfacility. !tt\[L/!b{RESPONSE:__________________________________________________________ 4.TurningRadius:Theminimumturningradiusshallbethirtysevenfeet. !tt\[L/!b{RESPONSE:__________________________________________________________ 5.Theminimumgatewidthshallbe20feetandaminimumverticalclearanceofthirteen(13)feet six(6)inchesisrequiredwhenthegateisatfullopenposition.Wherethereismorethanone gateandtwoormoredrivewaysseparatedbyislands,aminimumhorizontalclearanceoffifteen (15)feetforeachdrivewayandaminimumverticalclearanceofthirteen(13)feetsix(6)inchesis requiredwhengatesareatfullopenposition.Horizontaldistanceshallbemeasured perpendiculartothedirectionoftravelonthedriveway.Verticaldistanceshallbemeasuredfrom thehighestelevationofthedrivewaytothelowestoverheadobstruction. !tt\[L/!b{RESPONSE:__________________________________________________________ 6.Electricgatesshallbeequippedwithameansofopeningthegatebyfiredepartmentpersonnel foremergencyaccess.Emergencyopeningdevicesshallbeapprovedbythefirecodeofficial.All newconstructionofaccessgatesshallbeequippedwithanautomaticopeningdevicewhichis activatedthroughthewirelessactivationsystemutilizedonCityofBakersfieldownedvehiclesfor trafficpreemption.Installationandmaintenanceofthewirelessactivationsystemonaccess gate(s)shallbecompletedbythegateowner.Thegateopeningdeviceshallhaveadisconnect featureformanualoperationofthegatewhenthepowerfails. SPR220150Page|9of15 !tt\[L/!b{RESPONSE:__________________________________________________________ 7.Ifyouhandlehazardousmaterialsorhazardouswasteonthesite,thePreventionServicesDivision mayrequireahazardousmaterialmanagementand/orriskmanagementplanbeforeyoucan beginoperations.Pleasecontactthemat6613263979forfurtherinformation. !tt\[L/!b{RESPONSE:__________________________________________________________ 8.Ifyoustorehazardousmaterialsonthesiteineitheranundergroundorapermanent abovegroundstoragetank,apermitfromthePreventionServicesDivisionisrequiredtoinstall andoperatethesetanks.ThePreventionServicesDivisionmayalsorequireaSpillPrevention ControlandCountermeasurePlanforstorageofpetroleumproductsabovegroundinquantities of1,320gallonsormore.Pleasecontactthemat6613263979forfurtherinformation. !tt\[L/!b{RESPONSE:__________________________________________________________ 9.AllprojectsmustcomplywiththecurrentCaliforniaFireCodeandcurrentCityofBakersfield MunicipalCode. !tt\[L/!b{RESPONSE:__________________________________________________________ E.PUBLICWORKSENGINEERING(1501TruxtunAvenue) (StaffcontactΑSusannaKormendi;6613263997orskormendi@bakersfieldcity.us) 1.Thedevelopershallinstall 1 streetlightalong EastonDrive.Thedevelopershallberesponsible forprovidingthelaborandmaterialsnecessarytoenergizeallnewlyinstalledstreetlightsbefore occupancyofthebuildingorsite.Theseimprovementsshallbeshownonthefinalbuildingplans submittedtotheBuildingDivisionbeforeanybuildingpermitswillbeissued.Submitstreetlight locationandcontactthePublicWorksDepartmentat(661)3263584forstreetlightnumber. !tt\[L/!b{RESPONSE:__________________________________________________________ 2.Thedevelopershallinstallnewconnection(s)tothepublicsewersystem.Thisconnectionshall beshownonthefinalbuildingplanssubmittedtotheBuildingDivisionbeforeanybuildingpermits willbeissued. !tt\[L/!b{RESPONSE:__________________________________________________________ 3.Showonthefinalbuildingplansallexistingconnection(s)tothepublicsewersystem. !tt\[L/!b{RESPONSE:__________________________________________________________ 4.Allonsiteareasrequiredtobepaved(i.e.,parkinglots,accessdrives,loadingareas,etc.)shall consistofconcrete,asphalticconcrete(TypeB.A.C.)orotherpavedstreetmaterialapprovedby theCityEngineer.Pavementshallbeaminimumthicknessof2inchesover3inchesofapproved basematerial(i.e.,ClassIIA.B.)ifconcreteisused,itshallbeaminimumthicknessof4inchesper SPR220150Page|10of15 MunicipalCodeSection17.58.060.A.Thispavingstandardshallbenotedonthefinalbuilding planssubmittedtotheBuildingDivisionbeforeanybuildingpermitswillbeissued. !tt\[L/!b{RESPONSE:__________________________________________________________ 5.IfagradingplanisrequiredbytheBuildingDivision,buildingpermitswillnotbeissueduntilthe gradingplanisapprovedby both thePublicWorksDepartmentandtheBuildingDivision. !tt\[L/!b{RESPONSE:__________________________________________________________ 6.Allstormwatergeneratedontheprojectsite,includingthestreetfrontageshallberetainedonsite unlessotherwiseallowedbythePublicWorksDepartment(pleasecontactthePublicWorks DepartmentΑSubdivisionsat6613263576). !tt\[L/!b{RESPONSE:__________________________________________________________ 7.Iftheprojectgeneratesindustrialwaste,itshallbesubjecttotherequirementsoftheIndustrial WasteOrdinance.AnindustrialwastepermitmustbeobtainedfromthePublicWorks Departmentbeforeissuanceofthebuildingpermit.Tofindoutwhattypeofwasteisconsidered industrial,pleasecontacttheWastewaterTreatmentSuperintendentat6613263249. !tt\[L/!b{RESPONSE:__________________________________________________________ 8.Priortosubmittingrevisedplans,pleasecontacttheConstructionSuperintendentat661326 3049toscheduleasiteinspectiontofindoutwhatimprovementsmayberequired.Beforeany buildingorsitecanbeoccupied,thedevelopermustreconstructorrepairsubstandardoffsite streetimprovementsthatfrontthesitetoadoptedcitystandardsasdirectedbytheCityEngineer. Additionally,anyoffsite/frontageimprovementsorrepairsrequiredduringthesiteinspection shallbeshownonthegradingplan. !tt\[L/!b{RESPONSE:__________________________________________________________ 9.AstreetpermitfromthePublicWorksDepartmentshallbeobtainedbeforeanyworkcanbedone withinthepublicrightofway(streets,alleys,easements).Pleaseincludeacopyofthissiteplan reviewdecisiontothedepartmentatthetimeyouapplyforthispermit. !tt\[L/!b{RESPONSE:__________________________________________________________ 10.Asewerconnectionfeeshallbepaidatthetimeabuildingpermitisissued.Wewillbasethisfee attherateineffectatthetimeabuildingpermitisissued. !tt\[L/!b{RESPONSE:__________________________________________________________ 11.IftheprojectissubjecttotheprovisionsoftheNationalPollutantDischargeEliminationSystem (NPDES),aͻbƚƷźĭĻofLƓƷĻƓƷͼ(NOI)tocomplywiththetermsoftheGeneralPermittoDischarge StormWaterAssociatedwithConstructionActivity(SWRCBOrderNo.2009009DWQas amendedbyOrderNo.20100014DWQand20120006DWQ)mustbefiledwiththeStateWater SPR220150Page|11of15 ResourcesControlBoardinSacramentobeforethebeginningofanyconstructionactivity. CompliancewiththegeneralpermitrequiredthataStormWaterPollutionPreventionPlan (SWPPP)beprepared,continuouslycarriedout,andalwaysbeavailableforpublicinspection duringnormalconstructionhours. !tt\[L/!b{RESPONSE:__________________________________________________________ 12.Priortotheissuanceofeachbuildingpermit,orifnobuildingpermitisrequired,thefirstrequired Cityapprovalpriortoconstruction,thedeveloper/ownershallpayaTransportationImpactFee (TIF)forregionalfacilities.Thisfeewillbebasedontherateineffectatthetimetheapplicable approvalisissuedorinaccordancewiththeSubdivisionMapAct,asapplicable.ThePublicWorks Departmentwillcalculateanestimateofthetotalfeeuponsubmittalofconstructionplansfor theproject. !tt\[L/!b{RESPONSE:__________________________________________________________ 13.ThedevelopershallformanewMaintenanceDistrict.Undevelopedparcelswithinanexisting MaintenanceDistrictarerequiredtoupdateMaintenanceDistrictdocuments.Updated documents,includingProposition218BallotandCovenant,shallbesignedandnotarized.Ifthere arequestions,contactAdamCorderoat6613263576. (Note:Ifalreadywithinamaintenancedistrict,mayneedtoupdatethemaintenancedistrict form.) !tt\[L/!b{RESPONSE:__________________________________________________________ 14.Thedevelopershallinstallafullsizedmanholeineachsewerlineexceptresidentialdevelopment beforeitconnectstothesewermain.Thismanholeistobelocatedwithinthepropertybeing developedandmustbeeasilyaccessiblebyCityworkers. !tt\[L/!b{RESPONSE:__________________________________________________________ F.PUBLICWORKSTRAFFIC(1501TruxtunAvenue) (StaffcontactΑSusannaKormendi;6613263997orskormendi@bakersfieldcity.us) 1.Showonthefinalbuildingplans standardSt4 driveapproach(es).Driveapproachesmustbe centeredondriveaisles.Alldimensionsshallbeshownonthefinalbuildingplans. !tt\[L/!b{RESPONSE:__________________________________________________________ 2.Twowaydriveaislesshallbeaminimumwidthof24feet.Ifperpendicular(90º)parkingspaces areproposedwhereavehiclemustbackintotheseaisles,theminimumaislewidthshallbe25 feet.Alldriveaisledimensionshallbeshownonthefinalbuildingplans. !tt\[L/!b{RESPONSE:__________________________________________________________ SPR220150Page|12of15 3.Showthetypicalparkingstalldimensiononthefinalbuildingplans(minimumstallsizeis9feetx 18feetandshallbedesignedaccordingtostandardsestablishedbytheTrafficEngineer). !tt\[L/!b{RESPONSE:__________________________________________________________ 4.TheBakersfieldMunicipalCode(Section17.58.050.K.)prohibitsvehiclesfrombackingoutofa parkingspaceintoastreet.Pleaserevisetheparkingdesignonthefinalbuildingplanstoeliminate thesespaces. (Note:Thisprohibitiondoesnotincludesinglefamilyhomesinresidentialzones,ormultiple familyunitsonlocalstreetswheretheTrafficEngineerhasdeterminedthatbackingontoastreet willnotadverselyaffecttrafficandissimilartoasinglefamilyresidentialdrivewayuse.) !tt\[L/!b{RESPONSE:__________________________________________________________ 5.Gatemustbeplacedminimumof20feetfromEastonDriveflowlineifclosedduringregular businesshours. !tt\[L/!b{RESPONSE:__________________________________________________________ G.PUBLICWORKSSOLIDWASTE(4101TruxtunAvenue) (StaffContactRichardGutierrez:rmgutierrez@bakersfieldcity.us) 1.Youmustcontactthestaffpersonnotedabovebeforebuildingpermitscanbeissuedorwork beginsonthepropertytoestablishthelevelandtypeofservicenecessaryforthecollectionof refuseand/orrecycledmaterials.Collectionlocationsmustprovideenoughcontainmentareafor therefusethatisgeneratedwithoutviolatingrequiredzoningorsetbackrestrictions(seePlanning Divisionconditions).Levelsofservicearebasedonhowoftencollectionoccursasfollows: Frontloaderbinservices1cubicyard/week12cubicyards/day !tt\[L/!b{RESPONSE:__________________________________________________________ bedesigned 2.Showonthefinalbuildingplansrefuse/recyclebinenclosures.Eachenclosureshall accordingtoadoptedcitystandard(Detail#ST27andST28),atthesizecheckedbelow. Beforeoccupancyofthebuildingorsiteisallowed,_______________,_____________cubic yardfrontloadingtyperefuse/recyclebin(s)shallbeplacedwithintherequiredenclosure(s). ____________8'deepx20'wide(4bins) (Note:Allmeasurementsabovearecurbtocurbdimensionsinsidetheenclosure.Ifbothrefuse andrecyclingcontainersaretobecombinedinthesameenclosurearea,thisareamustbe expandedinsizetoaccommodatemultiplecontainers/binscontactthestaffpersonabovefor theappropriateenclosuresize.) SPR220150Page|13of15 !tt\[L/!b{RESPONSE:__________________________________________________________ 3.Examplesofenclosurestylescanbefoundon(Detail#ST27ST29B). !tt\[L/!b{RESPONSE:__________________________________________________________ 4.Facilitiesthatrequireinfectiouswasteservicesshallobtainapprovalforseparateinfectiouswaste storageareasfromtheKernCountyHealthDepartment.Innoinstancesshalltherefusebinarea beusedforinfectiouswastecontainmentpurposes. !tt\[L/!b{RESPONSE:__________________________________________________________ 5.Facilitiesthatrequiregreasecontainmentmustprovideastoragelocationthatisseparatefrom therefusebinlocation.Thisshallbeshownonthefinalbuildingplans.Ifagreaseinterceptoris tobeusedinsteadofagreasecontainmentbin,theplansmuststillshowthelocationofan adequatelysizedenclosureshouldagreasecontainmentbinberequiredatafuturedate.The greasecontainmentbinshallnotsharethesameenclosureastherefuse/recyclable/organicbin enclosure. !tt\[L/!b{RESPONSE:__________________________________________________________ 6.Facilitieswithexistingrefuseservicemustimprovetheservicelocationarea(s)accordingto adoptedCitystandards(Detail#ST27andST29B).Theseimprovementsshallbeclearlyshown onthefinalbuildingplans. !tt\[L/!b{RESPONSE:__________________________________________________________ 7.Ifutilitiesareincorporatedintotheenclosuredesign,theyshallnotinterferewithspaceprovided forrefusebinsandmust providesufficientprotectionmeasurestoguardtheutilitiesfrom damage. !tt\[L/!b{RESPONSE:__________________________________________________________ 8.Enclosuresshallnotbelocatedinanareathatwouldcauserefusetruckstointerferewithdrive thrutrafficflowenteringorexitingthesite,drivethrulanes,etc. !tt\[L/!b{RESPONSE:__________________________________________________________ 9.Businessesarerequiredtohavesufficientcapacityofrefuse/recycling/organicmaterialstorageto gowithoutservicefor1day(Sunday).Atanytime,refuse/recycling/organicservicesbecomean issue,businessesshallconstructasecondrefuseenclosuretomeetthedemand.Thesecond enclosureshallbeapprovedbytheCitypriortoconstruction. SPR220150Page|14of15 !tt\[L/!b{RESPONSE:__________________________________________________________ 10.Revisethesiteplantomakethetrashenclosureaccessibletotherefusetruck.Citytrucksmay notdrivedowndeadendcorridors,norbackuplongdistances;therefore,aturnaroundarea shallbeprovided. !tt\[L/!b{RESPONSE:__________________________________________________________ SPR220150Page|15of15