Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
3105 Auto Mall Drive (2)
SENTVIAUSMAILANDELECTRONICMAIL May6,2022 Applicant DukeEngineering Attn:ShawnaRicker 44732YuccaAvenue Lancaster,CA93534 PropertyOwner CardinaleAutomotiveGroup Attn:ChrisPullara 3239ImjinRoad Marina,CA93933 RE:NoticeofDecisionSitePlanReview(ProjectNo.220189)(Ward7) DearMs.Ricker: Theplansforconstructionof27,280SF2storyautomotivedealershipwithautomotiveservice/repairinC2(Regional CommercialZone)districtlocatedat3105AutoMallDrivehavebeenreviewedbytheSitePlanReviewCommitteeand itemsrequiringyourattentionareattached. Oncethecorrectionsnotedintheattachedsiteplancompliancelisthavebeenmade,theproposalwillmeetthe minimumrequiredcodes,policiesandstandardsfordevelopmentasadoptedbytheBakersfieldCityCouncil.Specific itemshavebeenidentified(seeattachedSitePlanComplianceList)thatyouneedtoresolvebeforeyoucanobtaina buildingpermitorbeallowedoccupancy.Theseitemsmayincludechangesoradditionsthatneedtobeshownonthe finalbuildingplans,alertyoutospecificfees,and/orarecommentsthatwillhelpyouincomplyingwiththeĭźƷǤƭ developmentstandards.Eachitemwillnotewhenitistobecompletedandtheyhavebeengroupedbydepartment sothatyouknowwhomtocontactifyouhavequestions. Yournextstepistoeitherapplyfornecessarybuildingpermitstoconstructyourproject,orbeginyourbusiness planstotheBuildingDivision.TheSite activitiesdependingontherequestsubmitted.Youmustsubmitfinalbuilding PlanReviewCommitteewillreviewthesefinalplanswhilebuildingplancheckoccurstoensurethatyousatisfythe itemsintheSitePlanComplianceList.Pleasereadthemcarefully.Failuretosatisfyanitemmaydelayyourobtaining abuildingpermitorcommencingyourproject. AfterconstructionofyourprojectbutbeforetheCitycanallowoccupancy,theBuildingDivisionmustinspectthe developmenttofindifitcomplieswiththeapprovedplans,andanyotherrelevantpermitsandcodes.Ifyouhave satisfiedalloftherequirements,theBuildingDirectorwillissueacertificateofoccupancy;ifnot,theareainspectorwill giveyouacorrectionnotice.Onceyouhavemadeallofthecorrections,theBuildingDirectorcanissueacertificateof occupancy.YoumaynotoccupyadevelopmentuntiltheBuildingDirectorhasissuedacertificateofoccupancy. INDEMNIFICATIONCONDITION InconsiderationbytheCityofBakersfieldforlanduseentitlements,includingbutnotlimitedtorelated environmentalapprovalsrelatedtoorarisingfromthisproject,theapplicant,and/orpropertyownerand/or subdividerΛͻ!ƦƦƌźĭğƓƷͼherein)agreestoindemnify,defend,andholdharmlesstheCityofBakersfield,itsofficers, agents,employees,departments,commissionersandboardsΛͻ/źƷǤͼherein)againstanyandallliability,claims, actions,causesofactionsordemandswhatsoeveragainstthem,oranyofthem,beforeadministrativeorjudicial tribunalsofanykindwhatsoever,inanywayarisingfrom,thetermsandprovisionsofthisapplication,including withoutlimitationanyCEQAapprovaloranyrelateddevelopmentapprovalsorconditionswhetherimposedby theCity,ornot,exceptfor/źƷǤƭsoleactivenegligenceorwillfulmisconduct. ThisindemnificationconditiondoesnotpreventtheApplicantfromchallenginganydecisionbytheCityrelatedto thisprojectandtheobligationsofthisconditionapplyregardlessofwhetheranyotherpermitsorentitlements areissued. TheCitywillpromptlynotifyApplicantofanysuchclaim,action,orproceeding,failingunderthisconditionwithin thirty(30)daysofactuallyreceivingsuchclaim.TheCity,initssolediscretion,shallbeallowedtochoosethe attorneyoroutsidelawfirmtodefendtheCityatthesolecostandexpenseoftheApplicantandtheCityisnot obligatedtouseanylawfirmorattorneychosenbyanotherentityorparty. REVISIONSTOTHEAPPROVEDPLAN Anytimeaftersiteplanapprovalbutbeforetheapprovalexpires,youmaysubmitrevisionstotheplan.Wewilltreat theserevisionsasanewsiteplanapplicationsubjecttoanewreviewandrequiredfees.ThePlanningDirectorcanonly approveminorchangestotheoriginalplanwithoutanewapplicationiftheyarenecessarytomeetacondition, mitigation,orresultfromphysicalobstaclesorothercomparableconstraints(SeeSection17.08.080.c.3oftheZoning Ordinance). EXPIRATIONOFPLANS Thissiteplanexpireson May5,2024(2yearsfromthedecisiondate),unlessbuildingpermitshavebeenissued, orwheretheusehascommencedonprojectsnotrequiringabuildingpermit.Theprojectmustbecompleted within5yearsfromthedecisiondate.Ifthepropertyisrezoned,siteplanapprovalwillexpireupontheeffective datefortherezoningunlesstheuseispermittedinthenewzone. ThePlanningDirectormayextendtheexpirationdateuptoone(1)yearifyouresubmitnewplansforcheck againstthecoderequirementsineffectatthattimeandincludeawrittenrequestfortheextension.Wemust receivethisrequest before expirationoftheprojectapproval.Wewillnotrequireafeeforthisextensionrequest; however,changestotheplansoriginallyapprovedforpurposesotherthancoderequirementsshallbesubjectto anewsiteplanreview,includingpaymentofallrequiredfees(SeeSection17.08.080.DoftheZoningOrdinance). ENVIRONMENTALDETERMINATION ThissiteplanreviewhasbeenfoundtobeexemptfromtheprovisionsoftheCaliforniaEnvironmentalQualityAct (CEQA)accordingtoSection15332.Thisprojectisexemptbecauseitisaninfilldevelopmentthatisconsistentwiththe generalplanandzoningregulations,iswithinanareapredominantlydevelopedwithurbanuses,isnotidentifiedas criticalhabitatforendangeredorthreatenedspecies,willnotsignificantlyaffecttrafficnoise,airorwaterquality,and willbeadequatelyservedbyappropriateutilitiesandpublicservices.ANoticeofExemptionhasbeenpreparedandis thePlanningDivision. availableforreviewat SPR220189Page|2of17 APPEAL Anypersonmayappealthisdecision.Anappealislimitedtowhetherornotanadopteddevelopmentstandard, zoningregulation,mitigation,orpolicyappliedornotappliedtotheproject,wasdoneconsistentwiththe authoritygrantedbycityordinancesortheCaliforniaEnvironmentalQualityAct(CEQA).Theappealmustbein ingtheprecisebasisorissueasnoted,mustincludetheappropriatefilingfee,andmustbefiledwithin writingstat 10days ofthedecisiondatetotheCityofBakersfieldPlanningCommission(c/oBakersfieldPlanningDirector, 1715ChesterAvenue,Bakersfield,CA93301).ThePlanningCommissionwillholdapublichearingontheappeal andtheirdecisionwillbefinalunlesstheirdecisionisappealedtotheCityCouncil. Siteplanapprovalisbasedonthestatementsmadeintheapplicationandtheplansyousubmitted.Anyerrorsor omissionsontheseplanscouldalterthecompliancelistand/orvoidthisdecision.Ifyouhavequestionsabout anyoftheitemsnotedintheSitePlanComplianceList,youmustspeaktothecontactpersonrepresentingthe departmentrequiringthatitem. Correspondencewillcontinuetobesenttotheapplicantonrecord.Shouldtheapplicantchange,itistheproperty ƚǞƓĻƩƭresponsibilitytoupdatethecontactinformationwiththePlanningDivision.Ifyouhaveotherquestions regardinggeneralinformationaboutthesiteplanreviewprocess,pleasecontactthePlanningDivisionat(661) 3263733. DECISIONDATE:May6,2022 Sincerely, LindaMitchell PrincipalPlanner 9ƓĭƌƚƭǒƩĻ cc:AllInterestedAgenciesΑForyourrecords. S:\\CounterOperations\\01_SPR\\2022\\220189_3105AutoMallDrive_PorcheDealership\\sprltr.docx SPR220189Page|3of17 CONDITIONSANDORDINANCECOMPLIANCE Thefollowingarespecificitemsthatyouneedtoresolvebeforeyoucanobtainabuildingpermitorbeallowed occupancy.Theseitemsincludeconditionsand/ormitigationrequiredbyprevioussiteentitlementapprovals (thesewillbespecificallynoted),changesoradditionsthatneedtobeshownonthefinalbuildingplans,alert youtospecificfees,andotherconditionsforyourprojecttosatisfythe/źƷǤƭdevelopmentstandards. Theitemslistedbelowwillusuallyneedtobeshownonthefinalbuildingplansorcompletedbeforeabuilding permitisissued.Aspartofthebuildingpermitsubmittal,identifythelocationofyourresponsebyusingthe !tt\[L/!b{RESPONSE lineprovideddirectlybelowtheitem(example:sheetnumber,detail,etc.). A.DEVELOPMENTSERVICESBUILDING(1715ChesterAvenue) (StaffcontactOscarFuentes;6613263676orOFuentes@bakersfieldcity.us) 1.PriortoreviewofimprovementplansbytheCity,thedevelopershallsubmitagradingplanfor theproposedsitetobereviewedandapprovedbytheCityEngineerandBuildingOfficial (BakersfieldMunicipalCodeSection16.44.010).Withthegradingplan,iftheprojectissubjectto theprovisionsoftheNationalPollutantDischargeEliminationSystem(NPDES),aNoticeofIntent (NOI)tocomplywiththetermsoftheGeneralPermittoDischargeStormWaterAssociatedwith ConstructionActivity(WQOrderNo.9908DWQ)mustbefiledwiththeStateWaterResources ControlBoardinSacramentobeforethebeginningofanyconstructionactivity.Compliancewith thegeneralpermitrequiresthataStormWaterPollutionPreventionPlan(SWPPP)beprepared, continuouslycarriedout,andalwaysbeavailableforpublicinspectionduringnormalconstruction hours. !tt\[L/!b{RESPONSE:__________________________________________________________ 2.Agradingpermitisrequiredpriortofinalplanapproval.Thedevelopershallsubmitfour(4)copies ofgradingplansandtwo(2)copiesofthepreliminarysoilsreporttotheBuildingDivision.Afinal soilsreportshallalsobesubmittedtotheBuildingDivisionbeforetheycanissueabuildingpermit. Pleasenotethatgradingplansmustbeconsistentwiththefinalbuildingsiteplansandlandscaping plans.BuildingpermitswillnotbeissueduntilthegradingpermitisapprovedbytheBuilding Division,PlanningDivision(HCP),andPublicWorksDepartment. !tt\[L/!b{RESPONSE:__________________________________________________________ 3.Showonthefinalbuildingplanpedestrianaccessfromthepublicwayandaccessibleparking. Privatestreetsarenotthepublicway. !tt\[L/!b{RESPONSE:__________________________________________________________ 4.Thedevelopershallincludefireresistivewallconstructiondetailswiththefinalbuildingplansfor allexteriorwallsofanybuildingthatiswithinthedistanceassetforthinTable602oftheCalifornia BuildingCode. SPR220189Page|4of17 !tt\[L/!b{RESPONSE:__________________________________________________________ 5.Includewithorshowonthefinalbuildingplansinformationnecessarytoverifythattheproject complieswithallaccessibilityrequirementsofTitle24oftheCaliforniaBuildingCode. !tt\[L/!b{RESPONSE:__________________________________________________________ 6.Buildingsorstructuresshallrequireinstallationofanautomaticfiresprinklersystemwhere requiredbycurrentCaliforniaBuildingCodeandCityordinance. !tt\[L/!b{RESPONSE:__________________________________________________________ 7.TheBuildingDivisionwillcalculateandcollecttheappropriateschooldistrictimpactfeeatthe timetheyissueabuildingpermit. !tt\[L/!b{RESPONSE:__________________________________________________________ 8.FinalBuildingplansshallshowpedestrianaccesspathwaysoreasementsforpersonswith frompublicrightsofwaysthatconnecttoallaccessiblebuildings,facilities,elements, disabilities andspacesinaccordancewiththeCaliforniaBuildingCode.Thesepedestrianaccesswaysshall notbeparalleltovehicularlanesunlessseparatedbycurbsorrailings. !tt\[L/!b{RESPONSE:__________________________________________________________ verifythatawatermeterservingthe 9.Priortograntingoccupancy,theBuildingDivisionwill developmentisinplace.Therefore,itisrecommendedthatthedevelopercontacttheapplicable waterpurveyortoinquireabouttheirprocessforobtainingwaterserviceforthedevelopmentas soonaspossible.Todeterminewhothewaterpurveyorforthedevelopmentis,youmaycontact theCityofBakersfieldWaterResourcesDepartment(1000BuenaVistaRoad,Bakersfield,CA, phone:6613263715). !tt\[L/!b{RESPONSE:__________________________________________________________ 10.Showonthefinalbuildingplan,electricvehiclesupplyequipmenttofacilitatefutureinstallation asrequiredbytheCaliforniaGreenCode. !tt\[L/!b{RESPONSE:__________________________________________________________ SPR220189Page|5of17 B.DEVELOPMENTSERVICESPLANNING(1715ChesterAvenue) (Staffcontact:RyderDilley6613263616orRDilley@bakersfieldcity.us) 1.Theminimumparkingrequiredforthisprojecthasbeencomputedbasedonuseandshallbeas follows: ProposedSquareParkingRequired UseFootageRatioParking GeneralOffice4,354sq.ft.1space/250sq.ft.17spaces VehicleSalesArea8,359sq.ft.1space/4,000sq.ft.2spaces Service/AutoRepair14,570sq.ft.1space/500sq.ft.29spaces TotalRequiredParking:48spaces (Note:86parkingspacesareshownontheproposedsiteplan.Byordinance,compactand tandemspacescannotbecountedtowardsmeetingminimumparkingrequirements.) !tt\[L/!b{RESPONSE:__________________________________________________________ 2.Minimumparkingstalldimensionsshallbe9feetwideby18feetlongandshallbedesigned accordingtostandardsestablishedbytheTrafficEngineer.Vehiclesmayhangoverlandscape areasnomorethan21/2feetprovidedrequiredsetbacksalongstreetfrontagesaremaintained, andtreesandshrubsareprotectedfromvehicles. !tt\[L/!b{RESPONSE:__________________________________________________________ 3.Allparkinglots,driveways,driveaisles,loadingareas,andothervehicularaccessways,shallbe pavedwithconcrete,asphalticconcrete,orotherpavedstreetsurfacingmaterialinaccordance withtheBakersfieldMunicipalCode(Sections15.76.020and17.58.060.A.). !tt\[L/!b{RESPONSE:__________________________________________________________ 4.Lightingisrequiredforallparkinglots,exceptresidentiallotswithfourunitsorless(Section 17.58.060.A.).Illuminationshallbeevenlydistributedacrosstheparkingareawithlightfixtures designedandarrangedsothatlightisdirecteddownwardandisreflectedawayfromadjacent propertiesandstreets.Useofglareshieldsorbafflesmayberequiredforglarereductionor controlofbacklight.Nolightpoles,standardsandfixtures,includingbasesorpedestals,shall exceedaheightof40feetabovegrade.However,lightstandardsplacedlessthan50feetfrom residentiallyzonedordesignatedproperty,orfromexistingresidentialdevelopment,shallnot exceedaheightof15feet.Thefinalbuildingplansshallincludeapictureordiagramofthelight fixturesbeingusedandshowhowlightwillbedirectedontotheparkingarea. (Note:Staffcanrequireadditionaladjustmentstoinstalledlightingafteroccupancytoresolve glareorotherlightingproblemsiftheynegativelyaffectadjacentproperties.) SPR220189Page|6of17 !tt\[L/!b{RESPONSE:__________________________________________________________ 5.Becauseparkingand/oraccessisbeingsharedwithadjacentproperties,thedevelopershallfile withthePlanningDivisionbeforeanybuildingpermitsareissuedacopyofarecordedmap, CC&Rs,orotherinstrumentthatensuresthatdriveaisles,parking,andaccessislegallysharedin commonwithadjoiningpropertiesasdepictedonthesiteplanforthelifeoftheproject. !tt\[L/!b{RESPONSE:__________________________________________________________ 6.Thedevelopershallincludeafinallandscapeplanwitheachsetofthebuildingplanssubmittedto theBuildingDivision.BuildingpermitswillnotbeissueduntilthePlanningDivisionhasapproved thefinallandscapeplanforconsistencywithapprovedsiteplansandminimumordinance standards.PleaserefertothelandscapingrequirementsinChapter17.61.Landscapeplansshall include,butarenotlimitedto,dataon:gallon/boxsize,spacing,species(referenceapproved parkinglottreelist),ratioofdeciduousvs.evergreen,shadecalculations,groundcover calculations,etc. (Note1:Atthetimeafinalsiteinspectionisconducted,itisexpectedthatplantswillmatchthe speciesidentifiedandbeinstalledinthelocationsconsistentwiththeapprovedlandscapeplan. ChangesmadewithoutpriorapprovalofthePlanningstaffmayresultintheremovaland/or relocationofinstalledplantmaterialsanddelaysinobtainingbuildingoccupancy.) (Note2:NomaturelandscapingshallberemovedwithoutpriorapprovalbythePlanning Director.) a. Uponapprovalofthefinallandscapeplan,adigitalcopyshallbesubmittedtothePlanning staffcontactlistedabove.) !tt\[L/!b{RESPONSE:__________________________________________________________ 7.Asolidmasonrywallshallbeconstructedadjacenttoresidentiallyzonedand/ordesignated property.Thiswallmustbeshownonthefinalbuildingplansandshallbeconstructedaminimum heightof6feetasmeasuredfromthehighestadjacentfinishedpropertygrade.Iftheparkinglot, includingdriveaisles,deliveryareas,loadingandunloadingareasarewithin10feetof residentiallyzonedproperty,a7footwidelandscapestripthatincludeslandscapingconsistent withChapter17.61shallbeinstalledbetweenthewallandparking/driveareas. !tt\[L/!b{RESPONSE:__________________________________________________________ 8.Streetaddressesfortheprojectshallbedesignatedbystaff.Thesenumberswillbetheonly addressesassignedbythecityunlessyouwishtohaveadifferentaddressprogram.Internal buildingunitaddresseswillbeonlybysuitenumberandwillbetheresponsibilityoftheowneror developertoassigntoeachtenant.PleasecontactKarlDavissonat6613263594forfurther information. !tt\[L/!b{RESPONSE:__________________________________________________________ SPR220189Page|7of17 9.Businessidentificationsignsare neitherconsiderednorapproved underthisreview(e.g.,wall, monument,pylon,etc.).AseparatesignpermitreviewedbythePlanningandBuildingDivisions andissuedbytheBuildingDivision,isrequiredforallnewsigns,includingfutureuseand constructionsigns. (Note:SignsmustcomplywiththeSignOrdinance;Chapter17.60oftheBakersfieldMunicipal Code.ReviewthisChapteraspartofduediligence.) !tt\[L/!b{RESPONSE:__________________________________________________________ 10.Thefollowingconditionsarerequiredaspartofagradingpermit: a.HabitatConservationfeesshallberequiredforthisprojectandwillbecalculatedbased onthefeeineffectatthetimeweissueanurbandevelopmentpermit(includesgrading planapprovals)asdefinedintheImplementation/ManagementAgreement(Section2.21) fortheMetropolitanBakersfieldHabitatConservationPlan.Uponpaymentofthefee, theapplicantwillreceiveacknowledgmentofcompliancewithMetropolitanBakersfield HabitatConservationPlan(Implementation/ManagementAgreementSection3.1.4).This feeiscurrently$2,145pergrossacres,payabletotheCityofBakersfield(submittothe PlanningDivision).Thisfeemustbepaidbeforeanygradingorothersitedisturbance occurs. FormsandinstructionsareavailableatthePlanningDivisionorontheĭźƷǤƭwebsiteat www.bakersfieldcity.us(gotoDevelopmentServicesDepartment). ThecurrentMetropolitanBakersfieldHabitatConservationPlan(MBHCP)expiresinyear 2023.Projectsmaybeissuedanurbandevelopmentpermit,gradingplanapproval,or buildingpermitandpayfeespriortothe2023expirationdateunderthecurrentMBHCP. AsdeterminedbytheCityofBakersfield,onlyprojectsreadytobeissuedanurban developmentpermit,gradingplanapprovalorbuildingpermitbeforethe2023expiration datewillbeeligibletopayfeesunderthecurrentMBHCP.Earlypaymentorprepayment ofMBHCPfeesshallnotbeallowed.TheabilityoftheCitytoissueurbandevelopment permitsisgovernedbythetermsoftheMBHCP.Urbandevelopmentpermitsissuedafter the2023expirationdatemaybesubjecttoaneworrevisedHabitatConservationPlan,if approved,orberequiredtocomplydirectlywithrequestsoftheU.S.FishandWildlife ServiceandtheCaliforniaDepartmentofFishandWildlife. b.BurrowingOwlNotification:Theburrowingowlisamigratorybirdspeciesprotectedby internationaltreatyundertheMigratoryBirdTreatyAct(MBTA)of1918(16U.S.C.703 711).TheMBTAmakesitunlawfultotake,possess,buy,sell,purchase,orbarterany migratorybirdlistedin50C.F.R.Part10includingfeathersorotherparts,nests,eggs,or products,exceptasallowedbyimplementingregulations(50C.F.R.21).Sections3503, 3503.5,and3800oftheCaliforniaFishandGameCodeprohibitthetaking,possession,or destructionofbirds,theirnestsoreggs.Toavoidviolationoftheprovisionsoftheselaws generallyrequiresthatprojectrelateddisturbanceatactivenestingterritoriesbereduced oreliminatedduringcriticalphasesofthenestingcycle(March1August15,annually). Disturbancethatcausesnestabandonmentand/orlossofreproductiveeffort(e.g.,killing SPR220189Page|8of17 orabandonmentofeggsoryoung)maybeconsideredͻƷğƉźƓŭͼandispotentially punishablebyfinesand/orimprisonment. c.Priortogrounddisturbance,thedevelopershallhaveaCaliforniaDepartmentofFishand WildlifeapprovedMBHCPbiologistsurveythelocationforkitfox,andcomplywiththe provisionsoftheMetropolitanBakersfieldHabitatConservationPlan.Surveyprotocol shallberecommendedbytheCaliforniaDepartmentofFishandWildlife.Developershall besubjecttothemitigationmeasuresrecommendedbythebiologist.Copiesofthe surveyshallbeprovidedtotheDevelopmentServicesDepartment,CaliforniaDepartment ofFishandWildlife,andtheU.S.FishandWildlifeServicepriortogrounddisturbance. !tt\[L/!b{RESPONSE:__________________________________________________________ 11.Rooftopareasofcommercialbuildings(e.g.,office,retail,restaurant,assembly,hotel,hospital, church,school),andindustrialbuildingsadjacenttoresidentiallyzonedproperties,shallbe completelyscreenedbyparapetsorotherfinishedarchitecturalfeaturesconstructedtoaheight ofthehighestequipment,unfinishedstructuralelementorunfinishedarchitecturalfeatureofthe building. !tt\[L/!b{RESPONSE:__________________________________________________________ 12.Openstorageofmaterialsandequipmentshallbesurroundedandscreenedwithasolidwallor fence(screeningalsoappliestogates).Thisfenceshallbeatleast6feetinheightandmaterials shallnotbestackedabovetheheightofthefence. (Note:Fencestallerthan6feetareallowedincommercialandindustrialzonesbuttheywill requireabuildingpermit.) !tt\[L/!b{RESPONSE:__________________________________________________________ 13.Areasusedforoutsidestorageshallbetreatedwithapermanentdustbinderorotherpermanent dustcontrolmeasureconsistentwiththeregulationsoftheSanJoaquinValleyAirPollution ControlDistrict. (Note:Allpassengervehicleparkingareasmustbepaved.) !tt\[L/!b{RESPONSE:__________________________________________________________ 14.Storageofmaterialsandmerchandiseisprohibitedunlessscreenedinaccordancewiththe municipalcode.Salesofmerchandiseshallnotbepermittedinanyrequiredparkingarea.Sales ofmerchandiseshallbeconductedand/orcontainedwithinanenclosedbuildingorwithina screenedareadedicatedforsuchuse. !tt\[L/!b{RESPONSE:__________________________________________________________ 15.Refusecollectionbinenclosuresandcontainerareasaresubjecttoallrequiredstructuralsetback fromstreetfrontages,andshallnotreduceanyparking,loadingorlandscapingareasasrequired bytheZoningOrdinance. SPR220189Page|9of17 !tt\[L/!b{RESPONSE:__________________________________________________________ 16.ThedevelopershallmeetallregulationsoftheSanJoaquinValleyAirPollutionControlDistrict (RegulationVIII)concerningdustsuppressionduringconstructionoftheproject.Methods include,butarenotlimitedto;useofwaterorchemicalstabilizer/suppressantstocontroldust emissionfromdisturbedarea,stockpiles,andaccessways;coveringorwettingmaterialsthatare transportedoffsite;limitconstructionrelatedspeedto15mphonallunpavedareas/washingof constructionvehiclesbeforetheyenterpublicstreetstominimizecarryout/trackout;andcease gradingandearthmovingduringperiodsofhighwinds(20mphormore). !tt\[L/!b{RESPONSE:__________________________________________________________ 17.Priortoreceivingfinalbuildingorsiteoccupancy,youmustcontactthePlanningDivision(staff contactnotedabove)forfinalinspectionandapprovalofthelandscaping,parkinglot,lightingand otherrelatedsiteimprovements.Inspectionswillnotbeconducteduntilallrequireditemshave beeninstalled.AnydeviationsfromtheapprovedplanswithoutpriorapprovalfromthePlanning Divisionmayresultinreconstructionanddelaysinobtainingabuildingorsiteoccupancy. !tt\[L/!b{RESPONSE:__________________________________________________________ C.FIREDEPARTMENT(2101HStreet) (StaffcontactErnieMedina;6613263682orEMedina@bakersfieldfire.us) 1.Showonthefinalbuildingplansthefollowingitems: a.Allfirelanes.AnymodificationsshallbeapprovedbytheFireDepartment.Firelane identificationsignsshallbeinstalledevery100feetwithredcurbingwhencurbingis required.Allworkshallbecompletedbeforeoccupancyofanybuildingorportionofany buildingisallowed. b.Allfirehydrants,bothoffsite(nearesttosite)andonsite.LƓĭƌǒķĻŅƌƚǞķğƷğƚƓğƌƌ ŷǤķƩğƓƷƭ͵Hydrantsshallbeingoodworkingconditionandaresubjecttotestingfor verification.Fireflowrequirementsmustbemetpriortoconstructioncommencingon theprojectsite.Pleaseprovidetwo(2)setsofthewaterplansstampedbyalicensed RegisteredCivilEngineertotheFireDepartmentandtwo(2)setstotheWaterResources Department(1000BuenaVistaRoad,Bakersfield,CA.93311;6613263715). (Note:Show:1)distancetothenearesthydrant;and2)distancefromthathydranttothe farthestpointoftheprojectsite.) c.Allfiresprinklerand/orstandpipesystems,firealarmsandcommercialhoodsystems. ThesesuppressionsystemsrequirereviewandpermitsbytheFireDepartment.TheFire Departmentwillissueguidelinesforthesevariousitemsastheymayapplytothisproject (deferredsubmittal:firesprinklerandfirealarminstall). SPR220189Page|10of17 d.Projectaddress,includingsuitenumberifapplicable.Iftheprojectiswithinashopping orbusinesscenter,notethenameandaddressofthecenter. e.Nameandphonenumberoftheappropriatecontactperson. !tt\[L/!b{RESPONSE:__________________________________________________________ 2.ThedevelopermustpayrequiredfeestoandrequestaninspectionfromtheWaterResources Department(1000BuenaVistaRoad,Bakersfield,CA,phone:6613263715)foranyunderground sprinklerfeedsatleast2fullbusinessdaysbeforetheyareburied.ThePreventionServices Division(2101HStreet,BakersfieldCA,Ph.661/3263979)mustcompleteallonsiteinspections offiresprinklersystemsandfirealarmsystemsbeforeanybuildingisoccupied. !tt\[L/!b{RESPONSE:__________________________________________________________ 3.Wherefireapparatusaccessroadsorawatersupplyforfireprotectionarerequiredtobe installed,suchprotectionshallbeinstalledandmadeserviceablepriortoandduringthetimeof construction. !tt\[L/!b{RESPONSE:__________________________________________________________ 4.Facilities,buildingsorportionsofbuildingshereafterconstructedshallbeaccessibletofire departmentapparatusbywayofan ğƦƦƩƚǝĻķŅźƩĻğƦƦğƩğƷǒƭğĭĭĻƭƭƩƚğķ withanasphalt,concrete orotherdrivingsurfaceapprovedbythefirechief.Mustbecapableofsupportingtheimposed loadoffireapparatusweighingatleast75,000poundsandshallbesurfacedwiththefirstliftof asphaltastoprovideallweatherdrivingcapabilities.Allaccess(Permanentandtemporary)to andaroundanybuildingunderconstructionmustbealeast20feetwide(26feetwidewhere buildingheightexceeds30feet),withanoverheadclearanceof13feet6inches,andcontainno obstruction.Thefireapparatusaccessroadshallextendtowithin150feetofallportionsofthe facilityandallportionsoftheexteriorwallsofthefirststoryofthebuildingasmeasuredbyan approvedroutearoundtheexteriorofthebuildingorfacility. !tt\[L/!b{RESPONSE:__________________________________________________________ 5.TurningRadius:Theminimumturningradiusshallbethirtysevenfeet. !tt\[L/!b{RESPONSE:__________________________________________________________ 6.Theminimumgatewidthshallbe20feetandaminimumverticalclearanceofthirteen(13)feet six(6)inchesisrequiredwhenthegateisatfullopenposition.Wherethereismorethanone gateandtwoormoredrivewaysseparatedbyislands,aminimumhorizontalclearanceoffifteen (15)feetforeachdrivewayandaminimumverticalclearanceofthirteen(13)feetsix(6)inchesis requiredwhengatesareatfullopenposition.Horizontaldistanceshallbemeasured perpendiculartothedirectionoftravelonthedriveway.Verticaldistanceshallbemeasuredfrom thehighestelevationofthedrivewaytothelowestoverheadobstruction. SPR220189Page|11of17 !tt\[L/!b{RESPONSE:__________________________________________________________ 7.Electricgatesshallbeequippedwithameansofopeningthegatebyfiredepartmentpersonnel foremergencyaccess.Emergencyopeningdevicesshallbeapprovedbythefirecodeofficial.All newconstructionofaccessgatesshallbeequippedwithanautomaticopeningdevicewhichis activatedthroughthewirelessactivationsystemutilizedonCityofBakersfieldownedvehiclesfor trafficpreemption.Installationandmaintenanceofthewirelessactivationsystemonaccess gate(s)shallbecompletedbythegateowner.Thegateopeningdeviceshallhaveadisconnect featureformanualoperationofthegatewhenthepowerfails. !tt\[L/!b{RESPONSE:__________________________________________________________ 8.Thedevelopershallsubmittwo(2)setsofplansforpermitsandapprovalsfromtheFire Departmentforfueltanksorrelatedfacilitiesbeforetheyareinstalledonthesite.Pleasecontact thePreventionServicesDivisionat6613263979forfurtherinformation. !tt\[L/!b{RESPONSE:__________________________________________________________ 9.Ifyouhandlehazardousmaterialsorhazardouswasteonthesite,thePreventionServicesDivision mayrequireahazardousmaterialmanagementand/orriskmanagementplanbeforeyoucan beginoperations.Pleasecontactthemat6613263979forfurtherinformation. !tt\[L/!b{RESPONSE:__________________________________________________________ 10.Ifyoustorehazardousmaterialsonthesiteineitheranundergroundorapermanent abovegroundstoragetank,apermitfromthePreventionServicesDivisionisrequiredtoinstall andoperatethesetanks.ThePreventionServicesDivisionmayalsorequireaSpillPrevention ControlandCountermeasurePlanforstorageofpetroleumproductsabovegroundinquantities of1,320gallonsormore.Pleasecontactthemat6613263979forfurtherinformation. !tt\[L/!b{RESPONSE:__________________________________________________________ 11.AllprojectsmustcomplywiththecurrentCaliforniaFireCodeandcurrentCityofBakersfield MunicipalCode. !tt\[L/!b{RESPONSE:__________________________________________________________ D.WATERRESOURCES(1000BuenaVistaRoad) (StaffcontactΑTylorHester;6613263009orTHester@bakersfieldcity.us) 1.PropertyislocatedoutsideoftheCityofBakersfielddomesticwaterservicearea,therefore,only pipelinesandappurtenancesrelatedtofirewateraresubjecttoreview. !tt\[L/!b{RESPONSE:__________________________________________________________ SPR220189Page|12of17 2.Developershallsubmittwo(2)setsofutilityplanssignedbyaCaliforniaRegisteredCivilEngineer totheWaterResourcesDepartmentshowingalloffsiteandonsiteimprovements,including connectionstotheexistingwatermainandundergroundfirewaterlinesandrelatedapparatuses. Includeanyexistingnearbyonoroffsitehydrants ontheplans.Plansshallbesubmittedalong withapplicableplancheckfeesandanyotherassociatedfeesperthecurrentfeeschedule.Plans shallcomplywithcurrentCityStandardsandSpecifications,CaliforniaFireCode,andCityof BakersfieldMunicipalCode.CityStandardsandSpecificationsandthecurrentFeeScheduleare availablefordownloadfromthe/źƷǤƭwebsiteat www.bakersfieldcity.us/gov/depts/water_resources/fees.htm !tt\[L/!b{RESPONSE:__________________________________________________________ 3.DevelopershallpaytherequiredWaterResourcesFireServiceInspectionFeesandsubmitan LƓƭƦĻĭƷźƚƓwĻƨǒĻƭƷCƚƩƒ foranyundergroundfirewaterlinesandtheirapparatusesatleasttwo (2)fullbusinessdaysbeforepermanentconstruction.Theformisavailablefordownloadfrom the/źƷǤƭwebsiteatwww.bakersfieldcity.us/gov/depts/water_resources/fees.htm !tt\[L/!b{RESPONSE:__________________________________________________________ E.PUBLICWORKSENGINEERING(1501TruxtunAvenue) (StaffcontactΑSusannaKormendi;6613263997orskormendi@bakersfieldcity.us) 1.Thedevelopershallinstallnewconnection(s)tothepublicsewersystem.Thisconnectionshall beshownonthefinalbuildingplanssubmittedtotheBuildingDivisionbeforeanybuildingpermits willbeissued. !tt\[L/!b{RESPONSE:__________________________________________________________ 2.Showonthefinalbuildingplansallexistingconnection(s)tothepublicsewersystem. !tt\[L/!b{RESPONSE:__________________________________________________________ 3.Allonsiteareasrequiredtobepaved(i.e.,parkinglots,accessdrives,loadingareas,etc.)shall consistofconcrete,asphalticconcrete(TypeB.A.C.)orotherpavedstreetmaterialapprovedby theCityEngineer.Pavementshallbeaminimumthicknessof2inchesover3inchesofapproved basematerial(i.e.,ClassIIA.B.)ifconcreteisused,itshallbeaminimumthicknessof4inchesper MunicipalCodeSection17.58.060.A.Thispavingstandardshallbenotedonthefinalbuilding planssubmittedtotheBuildingDivisionbeforeanybuildingpermitswillbeissued. !tt\[L/!b{RESPONSE:__________________________________________________________ 4.IfagradingplanisrequiredbytheBuildingDivision,buildingpermitswillnotbeissueduntilthe gradingplanisapprovedby both thePublicWorksDepartmentandtheBuildingDivision. !tt\[L/!b{RESPONSE:__________________________________________________________ SPR220189Page|13of17 5.Allstormwatergeneratedontheprojectsite,includingthestreetfrontageshallberetainedonsite unlessotherwiseallowedbythePublicWorksDepartment(pleasecontactthePublicWorks DepartmentΑSubdivisionsat6613263576). !tt\[L/!b{RESPONSE:__________________________________________________________ 6.Iftheprojectgeneratesindustrialwaste,itshallbesubjecttotherequirementsoftheIndustrial WasteOrdinance.AnindustrialwastepermitmustbeobtainedfromthePublicWorks Departmentbeforeissuanceofthebuildingpermit.Tofindoutwhattypeofwasteisconsidered industrial,pleasecontacttheWastewaterTreatmentSuperintendentat6613263249. !tt\[L/!b{RESPONSE:__________________________________________________________ 7.Priortosubmittingrevisedplans,pleasecontacttheConstructionSuperintendentat661326 3049toscheduleasiteinspectiontofindoutwhatimprovementsmayberequired.Beforeany buildingorsitecanbeoccupied,thedevelopermustreconstructorrepairsubstandardoffsite streetimprovementsthatfrontthesitetoadoptedcitystandardsasdirectedbytheCityEngineer. Additionally,anyoffsite/frontageimprovementsorrepairsrequiredduringthesiteinspection shallbeshownonthegradingplanorfinalbuildingplan. !tt\[L/!b{RESPONSE:__________________________________________________________ 8.AstreetpermitfromthePublicWorksDepartmentshallbeobtainedbeforeanyworkcanbedone withinthepublicrightofway(streets,alleys,easements).Pleaseincludeacopyofthissiteplan reviewdecisiontothedepartmentatthetimeyouapplyforthispermit. !tt\[L/!b{RESPONSE:__________________________________________________________ 9.Asewerconnectionfeeshallbepaidatthetimeabuildingpermitisissued.Wewillbasethisfee attherateineffectatthetimeabuildingpermitisissued. !tt\[L/!b{RESPONSE:__________________________________________________________ 10.IftheprojectissubjecttotheprovisionsoftheNationalPollutantDischargeEliminationSystem (NPDES),aͻbƚƷźĭĻofLƓƷĻƓƷͼ(NOI)tocomplywiththetermsoftheGeneralPermittoDischarge StormWaterAssociatedwithConstructionActivity(SWRCBOrderNo.2009009DWQas amendedbyOrderNo.20100014DWQand20120006DWQ)mustbefiledwiththeStateWater ResourcesControlBoardinSacramentobeforethebeginningofanyconstructionactivity. CompliancewiththegeneralpermitrequiredthataStormWaterPollutionPreventionPlan (SWPPP)beprepared,continuouslycarriedout,andalwaysbeavailableforpublicinspection duringnormalconstructionhours. !tt\[L/!b{RESPONSE:__________________________________________________________ 11.Priortotheissuanceofeachbuildingpermit,orifnobuildingpermitisrequired,thefirstrequired Cityapprovalpriortoconstruction,thedeveloper/ownershallpayaTransportationImpactFee (TIF)forregionalfacilities.Thisfeewillbebasedontherateineffectatthetimetheapplicable SPR220189Page|14of17 approvalisissuedorinaccordancewiththeSubdivisionMapAct,asapplicable.ThePublicWorks Departmentwillcalculateanestimateofthetotalfeeuponsubmittalofconstructionplansfor theproject. !tt\[L/!b{RESPONSE:__________________________________________________________ 12.ThedevelopershallformanewMaintenanceDistrict.Undevelopedparcelswithinanexisting MaintenanceDistrictarerequiredtoupdateMaintenanceDistrictdocuments.Updated documents,includingProposition218BallotandCovenant,shallbesignedandnotarized.Ifthere arequestions,contactAdamCorderoat6613263576. (Note:Ifalreadywithinamaintenancedistrict,mayneedtoupdatethemaintenancedistrict form.) !tt\[L/!b{RESPONSE:__________________________________________________________ 13.Thedevelopershallinstallafullsizedmanholeineachsewerlineexceptresidentialdevelopment beforeitconnectstothesewermain.Thismanholeistobelocatedwithinthepropertybeing developedandmustbeeasilyaccessiblebyCityworkers. !tt\[L/!b{RESPONSE:__________________________________________________________ F.PUBLICWORKSTRAFFIC(1501TruxtunAvenue) (StaffcontactΑSusannaKormendi;6613263997orskormendi@bakersfieldcity.us) 1.Streetreturntypeapproaches,ifused,shallhave20footminimumradiusreturns.Alldimensions shallbeshownonthefinalbuildingplans. !tt\[L/!b{RESPONSE:__________________________________________________________ 2.Twowaydriveaislesshallbeaminimumwidthof24feet.Ifperpendicular(90º)parkingspaces areproposedwhereavehiclemustbackintotheseaisles,theminimumaislewidthshallbe25 feet.Alldriveaisledimensionshallbeshownonthefinalbuildingplans. !tt\[L/!b{RESPONSE:__________________________________________________________ 3.Showthetypicalparkingstalldimensiononthefinalbuildingplans(minimumstallsizeis9feetx 18feetandshallbedesignedaccordingtostandardsestablishedbytheTrafficEngineer). !tt\[L/!b{RESPONSE:__________________________________________________________ SPR220189Page|15of17 G.PUBLICWORKSSOLIDWASTE(4101TruxtunAvenue) (StaffContactRichardGutierrez:rmgutierrez@bakersfieldcity.us) 1.Youmustcontactthestaffpersonnotedabovebeforebuildingpermitscanbeissuedorwork beginsonthepropertytoestablishthelevelandtypeofservicenecessaryforthecollectionof refuseand/orrecycledmaterials.Collectionlocationsmustprovideenoughcontainmentareafor therefusethatisgeneratedwithoutviolatingrequiredzoningorsetbackrestrictions(seePlanning Divisionconditions).Levelsofservicearebasedonhowoftencollectionoccursasfollows: Cartservice1cubicyard/weekorless1timeperweek Frontloaderbinservices1cubicyard/week12cubicyards/day RolloffcompactorserviceMorethan12cubicyards/day !tt\[L/!b{RESPONSE:__________________________________________________________ 2.Showonthefinalbuildingplansrefuse/recyclebinenclosures.Eachenclosureshallbedesigned accordingtoadoptedcitystandard(Detail#ST27andST28),atthesizecheckedbelow. Beforeoccupancyofthebuildingorsiteisallowed,4,3cubicyard frontloadingtype refuse/recyclebin(s)shallbeplacedwithintherequiredenclosure(s). 8'deepx15'wide(3bins) 8'deepx20'wide(4bins) 8'deepx10'wide;onskidsfordirectstabonly(16yardrecyclingbin) (Note:Allmeasurementsabovearecurbtocurbdimensionsinsidetheenclosure.Ifbothrefuse andrecyclingcontainersaretobecombinedinthesameenclosurearea,thisareamustbe expandedinsizetoaccommodatemultiplecontainers/binscontactthestaffpersonabovefor theappropriateenclosuresize.) !tt\[L/!b{RESPONSE:__________________________________________________________ 3.Examplesofenclosurestylescanbefoundon(Detail#ST27ST29B). !tt\[L/!b{RESPONSE:__________________________________________________________ 4.Facilitiesthatrequireinfectiouswasteservicesshallobtainapprovalforseparateinfectiouswaste storageareasfromtheKernCountyHealthDepartment.Innoinstancesshalltherefusebinarea beusedforinfectiouswastecontainmentpurposes. !tt\[L/!b{RESPONSE:__________________________________________________________ SPR220189Page|16of17 5.Facilitiesthatrequiregreasecontainmentmustprovideastoragelocationthatisseparatefrom therefusebinlocation.Thisshallbeshownonthefinalbuildingplans.Ifagreaseinterceptoris tobeusedinsteadofagreasecontainmentbin,theplansmuststillshowthelocationofan adequatelysizedenclosureshouldagreasecontainmentbinberequiredatafuturedate.The greasecontainmentbinshallnotsharethesameenclosureastherefuse/recyclable/organicbin enclosure. !tt\[L/!b{RESPONSE:__________________________________________________________ 6.Facilitieswithexistingrefuseservicemustimprovetheservicelocationarea(s)accordingto adoptedCitystandards(Detail #ST27andST29B).Theseimprovementsshallbeclearlyshown onthefinalbuildingplans. !tt\[L/!b{RESPONSE:__________________________________________________________ 7.Ifutilitiesareincorporatedintotheenclosuredesign,theyshallnotinterferewithspaceprovided forrefusebinsandmustprovidesufficientprotectionmeasurestoguardtheutilitiesfrom damage. !tt\[L/!b{RESPONSE:__________________________________________________________ 8.Enclosuresshallnotbelocatedinanareathatwouldcauserefusetruckstointerferewithdrive thrutrafficflowenteringorexitingthesite,drivethrulanes,etc. !tt\[L/!b{RESPONSE:__________________________________________________________ 9.Businessesarerequiredtohavesufficientcapacityofrefuse/recycling/organicmaterialstorageto gowithoutservicefor1day(Sunday).Atanytime,refuse/recycling/organicservicesbecomean issue,businessesshallconstructasecondrefuseenclosuretomeetthedemand.Thesecond enclosureshallbeapprovedbytheCitypriortoconstruction. !tt\[L/!b{RESPONSE:__________________________________________________________ 10.Revisethesiteplantomakethetrashenclosureaccessibletotherefusetruck.Citytrucksmay notdrivedowndeadendcorridors,norbackuplongdistances;therefore,aturnaroundarea shallbeprovided. !tt\[L/!b{RESPONSE:__________________________________________________________ SPR220189Page|17of17 4216!BVUPNBMM!ESJWF