Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
1401 Easton Drive (2)
SENTVIAUSMAILANDELECTRONICMAIL May9,2022 JaydevPatel 1017OakStreet Bakersfield,CA93304 RE:NoticeofDecisionSitePlanReview(ProjectNo.220181)(Ward2) DearMr.Patel: Theplansforconstructionofa4story,110roomhotel(approximately63,102squarefeet)withmeetingrooms intheC2(RegionalCommercialZone)districtlocatedat1401EastonDrivehavebeenreviewedbytheSitePlan ReviewCommitteeanditemsrequiringyourattentionareattached.ThisSitePlanReview(SPR)application replacestheexpiredSPR190393. Oncethecorrectionsnotedintheattachedsiteplancompliancelisthavebeenmade,theproposalwillmeetthe minimumrequiredcodes,policiesandstandardsfordevelopmentasadoptedbytheBakersfieldCityCouncil. Specificitemshavebeenidentified(seeattachedSitePlanComplianceList)thatyouneedtoresolvebeforeyou canobtainabuildingpermitorbeallowedoccupancy.Theseitemsmayincludechangesoradditionsthatneed tobeshownonthefinalbuildingplans,alertyoutospecificfees,and/orarecommentsthatwillhelpyouin complyingwiththeĭźƷǤƭdevelopmentstandards.Eachitemwillnotewhenitistobecompletedandtheyhave beengroupedbydepartmentsothatyouknowwhomtocontactifyouhavequestions. Yournextstepistoeitherapplyfornecessarybuildingpermitstoconstructyourproject,orbeginyourbusiness activitiesdependingontherequestsubmitted.YoumustsubmitfinalbuildingplanstotheBuildingDivision.The SitePlanReviewCommitteewillreviewthesefinalplanswhilebuildingplancheckoccurstoensurethatyousatisfy theitemsintheSitePlanComplianceList.Pleasereadthemcarefully.Failuretosatisfyanitemmaydelayyour obtainingabuildingpermitorcommencingyourproject. AfterconstructionofyourprojectbutbeforetheCitycanallowoccupancy,theBuildingDivisionmustinspectthe developmenttofindifitcomplieswiththeapprovedplans,andanyotherrelevantpermitsandcodes.Ifyouhave satisfiedalloftherequirements,theBuildingDirectorwillissueacertificateofoccupancy;ifnot,theareainspector willgiveyouacorrectionnotice.Onceyouhavemadeallofthecorrections,theBuildingDirectorcanissuea certificateofoccupancy.YoumaynotoccupyadevelopmentuntiltheBuildingDirectorhasissuedacertificateof occupancy. INDEMNIFICATIONCONDITION InconsiderationbytheCityofBakersfieldforlanduseentitlements,includingbutnotlimitedtorelatedenvironmental approvalsrelatedtoorarisingfromthisproject,theapplicant,and/orpropertyownerand/orsubdividerΛͻ!ƦƦƌźĭğƓƷͼ herein)agreestoindemnify,defend,andholdharmlesstheCityofBakersfield,itsofficers,agents,employees, departments,commissionersandboardsΛͻ/źƷǤͼherein)againstanyandallliability,claims,actions,causesofactions ordemandswhatsoeveragainstthem,oranyofthem,beforeadministrativeorjudicialtribunalsofanykind whatsoever,inanywayarisingfrom,thetermsandprovisionsofthisapplication,includingwithoutlimitationanyCEQA approvaloranyrelateddevelopmentapprovalsorconditionswhetherimposedbytheCity,ornot,exceptfor/źƷǤƭsole activenegligenceorwillfulmisconduct. ThisindemnificationconditiondoesnotpreventtheApplicantfromchallenginganydecisionbytheCityrelatedtothis applyregardlessofwhetheranyotherpermitsorentitlementsareissued. projectandtheobligationsofthiscondition TheCitywillpromptlynotifyApplicantofanysuchclaim,action,orproceeding,failingunderthisconditionwithinthirty (30)daysofactuallyreceivingsuchclaim.TheCity,initssolediscretion,shallbeallowedtochoosetheattorneyor outsidelawfirmtodefendtheCityatthesolecostandexpenseoftheApplicantandtheCityisnotobligatedtouseany lawfirmorattorneychosenbyanotherentityorparty. REVISIONSTOTHEAPPROVEDPLAN Anytimeaftersiteplanapprovalbutbeforetheapprovalexpires,youmaysubmitrevisionstotheplan.Wewill treattheserevisionsasanewsiteplanapplicationsubjecttoanewreviewandrequiredfees.ThePlanning Directorcanonlyapproveminorchangestotheoriginalplanwithoutanewapplicationiftheyarenecessaryto meetacondition,mitigation,orresultfromphysicalobstaclesorothercomparableconstraints(SeeSection 17.08.080.c.3oftheZoningOrdinance). EXPIRATIONOFPLANS Thissiteplanexpireson May8,2024(2yearsfromthedecisiondate),unlessbuildingpermitshavebeenissued, orwheretheusehascommencedonprojectsnotrequiringabuildingpermit.Theprojectmustbecompleted within5yearsfromthedecisiondate.Ifthepropertyisrezoned,siteplanapprovalwillexpireupontheeffective datefortherezoningunlesstheuseispermittedinthenewzone. ThePlanningDirectormayextendtheexpirationdateuptoone(1)yearifyouresubmitnewplansforcheck againstthecoderequirementsineffectatthattimeandincludeawrittenrequestfortheextension.Wemust receivethisrequest before expirationoftheprojectapproval.Wewillnotrequireafeeforthisextensionrequest; however,changestotheplansoriginallyapprovedforpurposesotherthancoderequirementsshallbesubjectto anewsiteplanreview,includingpaymentofallrequiredfees(SeeSection17.08.080.DoftheZoningOrdinance). ENVIRONMENTALDETERMINATION ThissiteplanreviewhasbeenfoundtobeexemptfromtheprovisionsoftheCaliforniaEnvironmentalQualityAct (CEQA)accordingtoSection15332.Thisprojectisexemptbecauseitisaninfilldevelopmentthatisconsistent withthegeneralplanandzoningregulations,iswithinanareapredominantlydevelopedwithurbanuses,isnot identifiedascriticalhabitatforendangeredorthreatenedspecies,willnotsignificantlyaffecttrafficnoise,airor waterquality,andwillbeadequatelyservedbyappropriateutilitiesandpublicservices.ANoticeofExemption hasbeenpreparedandisavailableforreviewatthePlanningDivision. SPR220181Page|2of14 APPEAL Anypersonmayappealthisdecision.Anappealislimitedtowhetherornotanadopteddevelopmentstandard, zoningregulation,mitigation,orpolicyappliedornotappliedtotheproject,wasdoneconsistentwiththe authoritygrantedbycityordinancesortheCaliforniaEnvironmentalQualityAct(CEQA).Theappealmustbein ingtheprecisebasisorissueasnoted,mustincludetheappropriatefilingfee,andmustbefiledwithin writingstat 10days ofthedecisiondatetotheCityofBakersfieldPlanningCommission(c/oBakersfieldPlanningDirector, 1715ChesterAvenue,Bakersfield,CA93301).ThePlanningCommissionwillholdapublichearingontheappeal andtheirdecisionwillbefinalunlesstheirdecisionisappealedtotheCityCouncil. Siteplanapprovalisbasedonthestatementsmadeintheapplicationandtheplansyousubmitted.Anyerrorsor omissionsontheseplanscouldalterthecompliancelistand/orvoidthisdecision.Ifyouhavequestionsabout anyoftheitemsnotedintheSitePlanComplianceList,youmustspeaktothecontactpersonrepresentingthe departmentrequiringthatitem. Correspondencewillcontinuetobesenttotheapplicantonrecord.Shouldtheapplicantchange,itistheproperty ƚǞƓĻƩƭresponsibilitytoupdatethecontactinformationwiththePlanningDivision.Ifyouhaveotherquestions regardinggeneralinformationaboutthesiteplanreviewprocess,pleasecontactthePlanningDivisionat(661) 3263733. DECISIONDATE:May9,2022 Sincerely, LindaMitchell PrincipalPlanner 9ƓĭƌƚƭǒƩĻ cc:AllInterestedAgenciesΑForyourrecords. S:\\CounterOperations\\01_SPR\\2022\\220181_1401EastonDrive_Hotel\\_sprltr.docx SPR220181Page|3of14 CONDITIONSANDORDINANCECOMPLIANCE Thefollowingarespecificitemsthatyouneedtoresolvebeforeyoucanobtainabuildingpermitorbeallowed occupancy.Theseitemsincludeconditionsand/ormitigationrequiredbyprevioussiteentitlementapprovals (thesewillbespecificallynoted),changesoradditionsthatneedtobeshownonthefinalbuildingplans,alert youtospecificfees,andotherconditionsforyourprojecttosatisfythe/źƷǤƭdevelopmentstandards. Theitemslistedbelowwillusuallyneedtobeshownonthefinalbuildingplansorcompletedbeforeabuilding permitisissued.Aspartofthebuildingpermitsubmittal,identifythelocationofyourresponsebyusingthe !tt\[L/!b{RESPONSE lineprovideddirectlybelowtheitem(example:sheetnumber,detail,etc.). A.DEVELOPMENTSERVICESBUILDING(1715ChesterAvenue) (StaffcontactOscarFuentes;6613263676orOFuentes@bakersfieldcity.us) 1.PriortoreviewofimprovementplansbytheCity,thedevelopershallsubmitagradingplanfor theproposedsitetobereviewedandapprovedbytheCityEngineerandBuildingOfficial (BakersfieldMunicipalCodeSection16.44.010).Withthegradingplan,iftheprojectissubjectto theprovisionsoftheNationalPollutantDischargeEliminationSystem(NPDES),aNoticeofIntent (NOI)tocomplywiththetermsoftheGeneralPermittoDischargeStormWaterAssociatedwith ConstructionActivity(WQOrderNo.9908DWQ)mustbefiledwiththeStateWaterResources ControlBoardinSacramentobeforethebeginningofanyconstructionactivity.Compliancewith thegeneralpermitrequiresthataStormWaterPollutionPreventionPlan(SWPPP)beprepared, continuouslycarriedout,andalwaysbeavailableforpublicinspectionduringnormalconstruction hours. !tt\[L/!b{RESPONSE:__________________________________________________________ 2.Agradingpermitisrequiredpriortofinalplanapproval.Thedevelopershallsubmitfour(4)copies ofgradingplansandtwo(2)copiesofthepreliminarysoilsreporttotheBuildingDivision.Afinal soilsreportshallalsobesubmittedtotheBuildingDivisionbeforetheycanissueabuildingpermit. Pleasenotethatgradingplansmustbeconsistentwiththefinalbuildingsiteplansandlandscaping plans.BuildingpermitswillnotbeissueduntilthegradingpermitisapprovedbytheBuilding Division,PlanningDivision(HCP),andPublicWorksDepartment. !tt\[L/!b{RESPONSE:__________________________________________________________ 3.Anapprovedsiteutilitiesplanisrequiredpriortofinalplanapproval. !tt\[L/!b{RESPONSE:__________________________________________________________ 4.Showonthefinalbuildingplanpedestrianaccessfromthepublicwayandaccessibleparking. Privatestreetsarenotthepublicway. !tt\[L/!b{RESPONSE:__________________________________________________________ SPR220181Page|4of14 5.Thedevelopershallincludefireresistivewallconstructiondetailswiththefinalbuildingplansfor allexteriorwallsofanybuildingthatiswithinthedistanceassetforthinTable602oftheCalifornia BuildingCode. !tt\[L/!b{RESPONSE:__________________________________________________________ 6.Includewithorshowonthefinalbuildingplansinformationnecessarytoverifythattheproject complieswithallaccessibilityrequirementsofTitle24oftheCaliforniaBuildingCode. !tt\[L/!b{RESPONSE:__________________________________________________________ 7.ThedevelopershallobtainallrequiredapprovalsfromtheKernCountyEnvironmentalHealth ServicesDepartment(2700ͻaͼStreet,Bakersfield,CA,93301;PH6618628700)foranypublic poolorrelatedfacilitybeforebuildingpermitscanbeissued.Disabledaccesstoanypublicpool andrelatedfacilityshallcomplywithTitle24oftheCaliforniaBuildingCode. !tt\[L/!b{RESPONSE:__________________________________________________________ 8.Buildingsorstructuresshallrequireinstallationofanautomaticfiresprinklersystemwhere requiredbycurrentCaliforniaBuildingCodeandCityordinance. !tt\[L/!b{RESPONSE:__________________________________________________________ 9.TheBuildingDivisionwillcalculateandcollecttheappropriateschooldistrictimpactfeeatthe timetheyissueabuildingpermit. !tt\[L/!b{RESPONSE:__________________________________________________________ 10.FinalBuildingplansshallshowpedestrianaccesspathwaysoreasementsforpersonswith disabilitiesfrompublicrightsofwaysthatconnecttoallaccessiblebuildings,facilities,elements, andspacesinaccordancewiththeCaliforniaBuildingCode.Thesepedestrianaccesswaysshall notbeparalleltovehicularlanesunlessseparatedbycurbsorrailings. !tt\[L/!b{RESPONSE:__________________________________________________________ 11.Priortograntingoccupancy,theBuildingDivisionwillverifythatawatermeterservingthe developmentisinplace.Therefore,itisrecommendedthatthedevelopercontacttheapplicable waterpurveyortoinquireabouttheirprocessforobtainingwaterserviceforthedevelopmentas soonaspossible.Todeterminewhothewaterpurveyorforthedevelopmentis,youmaycontact theCityofBakersfieldWaterResourcesDepartment(1000BuenaVistaRoad,Bakersfield,CA, phone:6613263715). !tt\[L/!b{RESPONSE:__________________________________________________________ SPR220181Page|5of14 12.Showonthefinalbuildingplan,electricvehiclesupplyequipmenttofacilitatefutureinstallation asrequiredbytheCaliforniaGreenCode. !tt\[L/!b{RESPONSE:__________________________________________________________ B.DEVELOPMENTSERVICESPLANNING(1715ChesterAvenue) (Staffcontact:VeronicaMartinezΑ6613263733orvmartinez@bakersfieldcity.us) 1. Providetherequiredminimum10footsetbackalongEastonDrive.Theproposed9feetwideby 18feetlongparkingspacesmay not encroachintotherequired10footsetback,unless,azoning modificationisapprovedtoallowtheproposedparkingspacestoencroachintothe10foot setback.PleasecontactPlanningDivisionforinformationaboutazoningmodificationprocess. 2.Theminimumparkingrequiredforthisprojecthasbeencomputedbasedonuseandshallbeas follows: ParkingRequired ProposedArea(SF)or UseNo.ofUnitsRatioParking Hotel1101space/unit110 Office407SF1space/250SF2spaces Meetingrooms18seats1space/4seats5spaces ______________________________________________________________________________ TotalRequiredParking:117spaces (Note:118totalparkingspaces,whichincludes6motorcycleparkingspacesareshownonthe proposedsiteplan.Byordinance,compactandtandemspacescannotbecountedtowards meetingminimumparkingrequirements.) !tt\[L/!b{RESPONSE:__________________________________________________________ 3.Lightingisrequiredforallparkinglots,exceptresidentiallotswithfourunitsorless(Section 17.58.060.A.).Illuminationshallbeevenlydistributedacrosstheparkingareawithlightfixtures designedandarrangedsothatlightisdirecteddownwardandisreflectedawayfromadjacent propertiesandstreets.Useofglareshieldsorbafflesmayberequiredforglarereductionor controlofbacklight.Nolightpoles,standardsandfixtures,includingbasesorpedestals,shall exceedaheightof40feetabovegrade.However,lightstandardsplacedlessthan50feetfrom residentiallyzonedordesignatedproperty,orfromexistingresidentialdevelopment,shallnot exceedaheightof15feet.Thefinalbuildingplansshallincludeapictureordiagramofthelight fixturesbeingusedandshowhowlightwillbedirectedontotheparkingarea. (Note:Staffcanrequireadditionaladjustmentstoinstalledlightingafteroccupancytoresolve glareorotherlightingproblemsiftheynegativelyaffectadjacentproperties.) !tt\[L/!b{RESPONSE:__________________________________________________________ SPR220181Page|6of14 4.Thedevelopershallincludeafinallandscapeplanwitheachsetofthebuildingplanssubmittedto theBuildingDivision.BuildingpermitswillnotbeissueduntilthePlanningDivisionhasapproved thefinallandscapeplanforconsistencywithapprovedsiteplansandminimumordinance standards.Pleaserefertothe landscapingrequirementsinChapter17.61.Landscapeplansshall include,butarenotlimitedto,dataon:gallon/boxsize,spacing,species(referenceapproved parkinglottreelist),ratioofdeciduousvs.evergreen,shadecalculations,groundcover calculations,etc. (Note1:Atthetimeafinalsiteinspectionisconducted,itisexpectedthatplantswillmatchthe speciesidentifiedandbeinstalledinthelocationsconsistentwiththeapprovedlandscapeplan. ChangesmadewithoutpriorapprovalofthePlanningstaffmayresultintheremovaland/or relocationofinstalledplantmaterialsanddelaysinobtainingbuildingoccupancy.) (Note2:NomaturelandscapingshallberemovedwithoutpriorapprovalbythePlanning Director.) a. Uponapprovalofthefinallandscapeplan,adigitalcopyshallbesubmittedtothePlanning staffcontactlistedabove. b. Providealegendforthelandscapingsymbols(e.g.,scrubs,trees,groundcover,etc.). c. Identifytheboxcontainersizeforthetreesandscrubstomeetthefollowinglandscaping requirementsidentifiedinBMC17.61.030.BandC. .͵ƩĻĻƭƭŷğƌƌĬĻğƒźƓźƒǒƒƷǞĻƓƷǤŅƚǒƩźƓĭŷĬƚǣĭƚƓƷğźƓĻƩƭźǩĻƚƩƌğƩŭĻƩğƓķƭŷğƌƌ ĬĻǝźŭƚƩƚǒƭğƓķŷĻğƌƷŷǤǞŷĻƓƦƌğƓƷĻķ͵ŷĻƒźƓźƒǒƒķźğƒĻƷĻƩƚŅƷŷĻƷƩĻĻƷƩǒƓƉͲğƭ ƒĻğƭǒƩĻķğƷğƦƚźƓƷŅƚǒƩŅĻĻƷǒƦƷŷĻƷƩǒƓƉŅƩƚƒŭƩƚǒƓķƌĻǝĻƌͲƭŷğƌƌĬĻƚƓĻźƓĭŷŅƚƩğ ŅźŅƷĻĻƓŭğƌƌƚƓĭƚƓƷğźƓĻƩƷƩĻĻͲƷǞƚźƓĭŷĻƭŅƚƩğƷǞĻƓƷǤŅƚǒƩźƓĭŷĬƚǣĭƚƓƷğźƓĻƩƷƩĻĻͲğƓķ ƷŷƩĻĻźƓĭŷĻƭŅƚƩğƷŷźƩƷǤƭźǣźƓĭŷĬƚǣĭƚƓƷğźƓĻƩƷƩĻĻ͵ŷĻƭĻƷƩǒƓƉķźğƒĻƷĻƩƭƭŷğƌƌğƦƦƌǤ ƷŷƩƚǒŭŷƚǒƷƷŷźƭĭŷğƦƷĻƩǞŷĻƩĻƷƩĻĻĭƚƓƷğźƓĻƩƭźǩĻƭğƩĻƭƦĻĭźŅźĻķ͵ /͵{ŷƩǒĬƭƭŷğƌƌĬĻğƒźƓźƒǒƒŅźǝĻŭğƌƌƚƓĭƚƓƷğźƓĻƩƭźǩĻƚƩƌğƩŭĻƩğƓķƭŷğƌƌĬĻǝźŭƚƩƚǒƭ ğƓķŷĻğƌƷŷǤǞŷĻƓƦƌğƓƷĻķ͵ağƭƭƭŷƩǒĬƦƌğƓƷźƓŭŅƚƩğƩĻğĭƚǝĻƩğŭĻƭŷğƌƌĬĻğƒźǣƚŅ ŅźǝĻŭğƌƌƚƓΛŅƚƩƷǤƦĻƩĭĻƓƷΜğƓķƚƓĻŭğƌƌƚƓΛƭźǣƷǤƦĻƩĭĻƓƷΜĭƚƓƷğźƓĻƩƭźǩĻǞźƷŷğƓ ğǝĻƩğŭĻƭƦğĭźƓŭƚŅĻźŭŷƷĻĻƓźƓĭŷĻƭƚƓĭĻƓƷĻƩ͵CƌğƷƭƭŷğƌƌĬĻǒƭĻķŅƚƩŭƩƚǒƓķĭƚǝĻƩƭ ǞźƷŷğƓğǝĻƩğŭĻƭƦğĭźƓŭƚŅĻźŭŷƷźƓĭŷĻƭƚƓĭĻƓƷĻƩ͵ d. Showandidentifytherequiredminimum8footlandscapebufferalongalocalstreet(i.e., EastonDrive). !tt\[L/!b{RESPONSE:__________________________________________________________ 5.Priortoreceivingfinalbuildingorsiteoccupancy,youmustcontactthePlanningDivision(staff contactnotedabove)forfinalinspectionandapprovalofthelandscaping,parkinglot,lightingand otherrelatedsiteimprovements.Inspectionswillnotbeconducteduntilallrequireditemshave beeninstalled.AnydeviationsfromtheapprovedplanswithoutpriorapprovalfromthePlanning Divisionmayresultinreconstructionanddelaysinobtainingabuildingorsiteoccupancy. SPR220181Page|7of14 !tt\[L/!b{RESPONSE:__________________________________________________________ C.FIREDEPARTMENT(2101HStreet) (StaffcontactErnieMedina;6613263682orEMedina@bakersfieldfire.us) 1.Showonthefinalbuildingplansthefollowingitems: a.Allfirelanes.AnymodificationsshallbeapprovedbytheFireDepartment.Firelane identificationsignsshallbeinstalledevery100feetwithredcurbingwhencurbingis required.Allworkshallbecompletedbeforeoccupancyofanybuildingorportionofany buildingisallowed. b.Allfirehydrants,bothoffsite(nearesttosite)andonsite.LƓĭƌǒķĻŅƌƚǞķğƷğƚƓğƌƌ ŷǤķƩğƓƷƭ͵Hydrantsshallbeingoodworkingconditionandaresubjecttotestingfor verification.Fireflowrequirementsmustbemetpriortoconstructioncommencingon theprojectsite.Pleaseprovidetwo(2)setsofthewaterplansstampedbyalicensed RegisteredCivilEngineertotheFireDepartmentandtwo(2)setstotheWaterResources Department(1000BuenaVistaRoad,Bakersfield,CA.93311;6613263715). (Note:Show:1)distancetothenearesthydrant;and2)distancefromthathydranttothe farthestpointoftheprojectsite.) c.Allfiresprinklerand/orstandpipesystems,firealarmsandcommercialhoodsystems. ThesesuppressionsystemsrequirereviewandpermitsbytheFireDepartment.TheFire Departmentwillissueguidelinesforthesevariousitemsastheymayapplytothisproject. !tt\[L/!b{RESPONSE:__________________________________________________________ 2.ThedevelopermustpayrequiredfeestoandrequestaninspectionfromtheWaterResources Department(1000BuenaVistaRoad,Bakersfield,CA,phone:6613263715)foranyunderground sprinklerfeedsatleast2fullbusinessdaysbeforetheyareburied.ThePreventionServices Division(2101HStreet,BakersfieldCA,Ph.661/3263979)mustcompleteallonsiteinspections offiresprinklersystemsandfirealarmsystemsbeforeanybuildingisoccupied. !tt\[L/!b{RESPONSE:__________________________________________________________ 3.Wherefireapparatusaccessroadsorawatersupplyforfireprotectionarerequiredtobe installed,suchprotectionshallbeinstalledandmadeserviceablepriortoandduringthetimeof construction. !tt\[L/!b{RESPONSE:__________________________________________________________ 4.Facilities,buildingsorportionsofbuildingshereafterconstructedshallbeaccessibletofire departmentapparatusbywayofan ğƦƦƩƚǝĻķŅźƩĻğƦƦğƩğƷǒƭğĭĭĻƭƭƩƚğķ withanasphalt,concrete orotherdrivingsurfaceapprovedbythefirechief.Mustbecapableofsupportingtheimposed SPR220181Page|8of14 loadoffireapparatusweighingatleast75,000poundsandshallbesurfacedwiththefirstliftof asphaltastoprovideallweatherdrivingcapabilities.Allaccess(Permanentandtemporary)to andaroundanybuildingunderconstructionmustbealeast20feetwide(26feetwidewhere buildingheight exceeds30feet),withanoverheadclearanceof13feet6inches,andcontainno obstruction.Thefireapparatusaccessroadshallextendtowithin150feetofallportionsofthe facilityandallportionsoftheexteriorwallsofthefirststoryofthebuildingasmeasuredby an approvedroutearoundtheexteriorofthebuildingorfacility. !tt\[L/!b{RESPONSE:__________________________________________________________ 5.Theminimumgatewidthshallbe20feetandaminimumverticalclearanceofthirteen(13)feet six(6)inchesisrequiredwhenthegateisatfullopenposition.Wherethereismorethanonegate andtwoormoredrivewaysseparatedbyislands,aminimumhorizontalclearanceoffifteen(15) feetforeachdrivewayandaminimumverticalclearanceofthirteen(13)feetsix(6)inchesis requiredwhengatesareatfullopenposition.Horizontaldistanceshallbemeasured perpendiculartothedirectionoftravelonthedriveway.Verticaldistanceshallbemeasuredfrom thehighestelevationofthedrivewaytothelowestoverheadobstruction. (Note1:Providethegatewidthonplans.) 6.AllprojectsmustcomplywiththecurrentCaliforniaFireCodeandcurrentCityofBakersfield MunicipalCode. !tt\[L/!b{RESPONSE:__________________________________________________________ D.WATERRESOURCES(1000BuenaVistaRoad) (StaffcontactΑTylorHester;6613263009orTHester@bakersfieldcity.us) 1.Developershallsubmittwo(2)setsofutilityplanssignedbyaCaliforniaRegisteredCivilEngineer totheWaterResourcesDepartmentshowingalloffsiteandonsiteimprovements,including connectionstotheexistingwatermainandundergroundfirewaterlinesandrelatedapparatuses. Includeanyexistingnearbyonoroffsitehydrantsontheplans.Plansshallbesubmittedalong withapplicableplancheckfeesandanyotherassociatedfeesperthecurrentfeeschedule.Plans shallcomplywithcurrentCityStandardsandSpecifications,CaliforniaFireCode,andCityof BakersfieldMunicipalCode.CityStandardsandSpecificationsandthecurrentFeeScheduleare availablefordownloadfromthe/źƷǤƭwebsiteat www.bakersfieldcity.us/gov/depts/water_resources/fees.htm !tt\[L/!b{RESPONSE:__________________________________________________________ 2.DevelopershallpaytherequiredWaterResourcesFireServiceInspectionFeesandsubmitan LƓƭƦĻĭƷźƚƓwĻƨǒĻƭƷCƚƩƒ foranyundergroundfirewaterlinesandtheirapparatusesatleasttwo (2)fullbusinessdaysbeforepermanentconstruction.Theformisavailablefordownloadfrom the/źƷǤƭwebsiteatwww.bakersfieldcity.us/gov/depts/water_resources/fees.htm. SPR220181Page|9of14 !tt\[L/!b{RESPONSE:__________________________________________________________ E.PUBLICWORKSENGINEERING(1501TruxtunAvenue) (StaffcontactΑSusannaKormendi;6613263997orskormendi@bakersfieldcity.us) 1.Thedevelopershallinstallnewconnection(s)tothepublicsewersystem.Thisconnectionshall beshownonthefinalbuildingplanssubmittedtotheBuildingDivisionbeforeanybuildingpermits willbeissued. !tt\[L/!b{RESPONSE:__________________________________________________________ 2.Showonthefinalbuildingplansallexistingconnection(s)tothepublicsewersystem. !tt\[L/!b{RESPONSE:__________________________________________________________ 3.IfagradingplanisrequiredbytheBuildingDivision,buildingpermitswillnotbeissueduntilthe gradingplanisapprovedby both thePublicWorksDepartmentandtheBuildingDivision. !tt\[L/!b{RESPONSE:__________________________________________________________ 4.Allstormwatergeneratedontheprojectsite,includingthestreetfrontageshallberetainedonsite unlessotherwiseallowedbythePublicWorksDepartment(pleasecontactthePublicWorks DepartmentΑSubdivisionsat6613263576). !tt\[L/!b{RESPONSE:__________________________________________________________ 5.Iftheprojectgeneratesindustrialwaste,itshallbesubjecttotherequirementsoftheIndustrial WasteOrdinance.AnindustrialwastepermitmustbeobtainedfromthePublicWorks Departmentbeforeissuanceofthebuildingpermit.Tofindoutwhattypeofwasteisconsidered industrial,pleasecontacttheWastewaterTreatmentSuperintendentat6613263249. !tt\[L/!b{RESPONSE:__________________________________________________________ 6.Priortosubmittingrevisedplans,pleasecontacttheConstructionSuperintendentat661326 3049toscheduleasiteinspectiontofindoutwhatimprovementsmayberequired.Beforeany buildingorsitecanbeoccupied,thedevelopermustreconstructorrepairsubstandardoffsite streetimprovementsthatfrontthesitetoadoptedcitystandardsasdirectedbytheCityEngineer. Additionally,anyoffsite/frontageimprovementsorrepairsrequiredduringthesiteinspection shallbeshownonthegradingplan. !tt\[L/!b{RESPONSE:__________________________________________________________ 7.AstreetpermitfromthePublicWorksDepartmentshallbeobtainedbeforeanyworkcanbedone withinthepublicrightofway(streets,alleys,easements).Pleaseincludeacopyofthissiteplan reviewdecisiontothedepartmentatthetimeyouapplyforthispermit. SPR220181Page|10of14 !tt\[L/!b{RESPONSE:__________________________________________________________ 8.Asewerconnectionfeeshallbepaidatthetimeabuildingpermitisissued.Wewillbasethisfee attherateineffectatthetimeabuildingpermitisissued. !tt\[L/!b{RESPONSE:__________________________________________________________ 9.IftheprojectissubjecttotheprovisionsoftheNationalPollutantDischargeEliminationSystem (NPDES),aͻbƚƷźĭĻofLƓƷĻƓƷͼ(NOI)tocomplywiththetermsoftheGeneralPermittoDischarge StormWaterAssociatedwithConstructionActivity(SWRCBOrderNo.2009009DWQas amendedbyOrderNo.20100014DWQand20120006DWQ)mustbefiledwiththeStateWater ResourcesControlBoardinSacramentobeforethebeginningofanyconstructionactivity. CompliancewiththegeneralpermitrequiredthataStormWaterPollutionPreventionPlan (SWPPP)beprepared,continuouslycarriedout,andalwaysbeavailableforpublicinspection duringnormalconstructionhours. !tt\[L/!b{RESPONSE:__________________________________________________________ 10.Priortotheissuanceofeachbuildingpermit,orifnobuildingpermitisrequired,thefirstrequired Cityapprovalpriortoconstruction,thedeveloper/ownershallpayaTransportationImpactFee (TIF)forregionalfacilities.Thisfeewillbebasedontherateineffectatthetimetheapplicable approvalisissuedorinaccordancewiththeSubdivisionMapAct,asapplicable.ThePublicWorks Departmentwillcalculateanestimateofthetotalfeeuponsubmittalofconstructionplansfor theproject. !tt\[L/!b{RESPONSE:__________________________________________________________ 11.ThedevelopershallformanewMaintenanceDistrict.Undevelopedparcelswithinanexisting MaintenanceDistrictarerequiredtoupdateMaintenanceDistrictdocuments.Updated documents,includingProposition218BallotandCovenant,shallbesignedandnotarized.Ifthere arequestions,contactAdamCorderoat6613263576. (Note:Ifalreadywithinamaintenancedistrict,mayneedtoupdatethemaintenancedistrict form.) !tt\[L/!b{RESPONSE:__________________________________________________________ 12.Thedevelopershallinstallafullsizedmanholeineachsewerlineexceptresidentialdevelopment beforeitconnectstothesewermain.Thismanholeistobelocatedwithinthepropertybeing developedandmustbeeasilyaccessiblebyCityworkers. !tt\[L/!b{RESPONSE:__________________________________________________________ SPR220181Page|11of14 F.PUBLICWORKSTRAFFIC(1501TruxtunAvenue) (StaffcontactΑSusannaKormendi;6613263997orskormendi@bakersfieldcity.us) 1.Showonthefinalbuildingplans standardST4 driveapproach(es).Driveapproachesmustbe centeredondriveaisles.Alldimensionsshallbeshownonthefinalbuildingplans. !tt\[L/!b{RESPONSE:__________________________________________________________ 2.Streetreturntypeapproaches,ifused,shallhave20footminimumradiusreturnswitha 26ЌЉ throatwidth.Alldimensionsshallbeshownonthefinalbuildingplans. !tt\[L/!b{RESPONSE:__________________________________________________________ 3.ThedevelopershalldedicateanysidewalkextendingoutoftherightofwaytotheCityof Bakersfieldforthepedestrianwayalongallarterialstreets.Thismustbeconductedwitha separateinstrumentorfinalmap. !tt\[L/!b{RESPONSE:__________________________________________________________ G.PUBLICWORKSSOLIDWASTE(4101TruxtunAvenue) (StaffContactRichardGutierrez:rmgutierrez@bakersfieldcity.us) 1.Youmustcontactthestaffpersonnotedabovebeforebuildingpermitscanbeissuedorwork beginsonthepropertytoestablishthelevelandtypeofservicenecessaryforthecollectionof refuseand/orrecycledmaterials.Collectionlocationsmustprovideenoughcontainmentareafor therefusethatisgeneratedwithoutviolatingrequiredzoningorsetbackrestrictions(seePlanning Divisionconditions).Levelsofservicearebasedonhowoftencollectionoccursasfollows: Cartservice1cubicyard/weekorless1timeperweek Frontloaderbinservices1cubicyard/week12cubicyards/day RolloffcompactorserviceMorethan12cubicyards/day !tt\[L/!b{RESPONSE:__________________________________________________________ 2.Showonthefinalbuildingplansrefuse/recyclebinenclosures.Eachenclosureshallbedesigned accordingtoadoptedcitystandard(Detail#ST27andST28),atthesizecheckedbelow. allowed,4,4 cubicyardfrontloadingtype Beforeoccupancyofthebuildingorsiteis refuse/recyclebin(s)shallbeplacedwithintherequiredenclosure(s). ____________8'deepx15'wide(3bins) ____________8'deepx20'wide(4bins) ____________8'deepx10'wide;onskidsfordirectstabonly(16yardrecyclingbin) SPR220181Page|12of14 (Note:Allmeasurementsabovearecurbtocurbdimensionsinsidetheenclosure.Ifbothrefuse andrecyclingcontainersaretobecombinedinthesameenclosurearea,thisareamustbe expandedinsizetoaccommodatemultiplecontainers/binscontactthestaffpersonabovefor theappropriateenclosuresize.) !tt\[L/!b{RESPONSE:__________________________________________________________ 3.Examplesofenclosurestylescanbefoundon(Detail#ST27ST29B). !tt\[L/!b{RESPONSE:__________________________________________________________ 4.Facilitiesthatrequireinfectiouswasteservicesshallobtainapprovalforseparateinfectiouswaste storageareasfromtheKernCountyHealthDepartment.Innoinstancesshalltherefusebinarea beusedforinfectiouswastecontainmentpurposes. !tt\[L/!b{RESPONSE:__________________________________________________________ 5.Facilitiesthatrequiregreasecontainmentmustprovideastoragelocationthatisseparatefrom therefusebinlocation.Thisshallbeshownonthefinalbuildingplans.Ifagreaseinterceptoris tobeusedinsteadofagreasecontainmentbin,theplansmuststillshowthelocationofan adequatelysizedenclosureshouldagreasecontainmentbinberequiredatafuturedate.The greasecontainmentbinshallnotsharethesameenclosureastherefuse/recyclable/organicbin enclosure. !tt\[L/!b{RESPONSE:__________________________________________________________ 6.Facilitieswithexistingrefuseservicemustimprovetheservicelocationarea(s)accordingto adoptedCitystandards(Detail#ST27andST29B).Theseimprovementsshallbeclearlyshown onthefinalbuildingplans. !tt\[L/!b{RESPONSE:__________________________________________________________ 7.Ifutilitiesareincorporatedintotheenclosuredesign,theyshallnotinterferewithspaceprovided forrefusebinsandmustprovidesufficientprotectionmeasurestoguardtheutilitiesfrom damage. !tt\[L/!b{RESPONSE:__________________________________________________________ 8.Enclosuresshallnotbelocatedinanareathatwouldcauserefusetruckstointerferewithdrive thrutrafficflowenteringorexitingthesite,drivethrulanes,etc. !tt\[L/!b{RESPONSE:__________________________________________________________ SPR220181Page|13of14 9.Businessesarerequiredtohavesufficientcapacityofrefuse/recycling/organicmaterialstorageto gowithoutservicefor1day(Sunday).Atanytime,refuse/recycling/organicservicesbecomean issue,businessesshallconstructasecondrefuseenclosuretomeetthedemand.Thesecond enclosureshallbeapprovedbytheCitypriortoconstruction. !tt\[L/!b{RESPONSE:__________________________________________________________ 10.Revisethesiteplantomakethetrashenclosureaccessibletotherefusetruck.Citytrucksmay notdrivedowndeadendcorridors,norbackuplongdistances;therefore,aturnaroundarea shallbeprovided. !tt\[L/!b{RESPONSE:__________________________________________________________ SPR220181Page|14of14