HomeMy WebLinkAbout816 Pacific Street SENTVIAUSMAILANDELECTRONICMAIL May10,2022 AbelVillanueva 1800OakStreet,SuiteA Bakersfield,CA93301 RE:NoticeofDecisionSitePlanReview(ProjectNo.220158)(Ward2) DearMr.Villanueva: Theplansforconstructionoftwo(2)587squarefootadditionaldwellingunits(totalof3)inanR3(Limited MultipleFamilyDwellingZone)districtlocatedat816PacificStreethavebeenreviewedbytheSitePlanReview Committeeanditemsrequiringyourattentionareattached. Oncethecorrectionsnotedintheattachedsiteplancompliancelisthavebeenmade,theproposalwillmeetthe minimumrequiredcodes,policiesandstandardsfordevelopmentasadoptedbytheBakersfieldCityCouncil. Specificitemshavebeenidentified(seeattachedSitePlanComplianceList)thatyouneedtoresolvebeforeyou canobtainabuildingpermitorbeallowedoccupancy.Theseitemsmayincludechangesoradditionsthatneed tobeshownonthefinalbuildingplans,alertyoutospecificfees,and/orarecommentsthatwillhelpyouin complyingwiththeĭźƷǤ͸ƭdevelopmentstandards.Eachitemwillnotewhenitistobecompletedandtheyhave beengroupedbydepartmentsothatyouknowwhomtocontactifyouhavequestions. Yournextstepistoeitherapplyfornecessarybuildingpermitstoconstructyourproject,orbeginyourbusiness activitiesdependingontherequestsubmitted.YoumustsubmitfinalbuildingplanstotheBuildingDivision.The SitePlanReviewCommitteewillreviewthesefinalplanswhilebuildingplancheckoccurstoensurethatyousatisfy theitemsintheSitePlanComplianceList.Pleasereadthemcarefully.Failuretosatisfyanitemmaydelayyour obtainingabuildingpermitorcommencingyourproject. AfterconstructionofyourprojectbutbeforetheCitycanallowoccupancy,theBuildingDivisionmustinspectthe developmenttofindifitcomplieswiththeapprovedplans,andanyotherrelevantpermitsandcodes.Ifyouhave satisfiedalloftherequirements,theBuildingDirectorwillissueacertificateofoccupancy;ifnot,theareainspector willgiveyouacorrectionnotice.Onceyouhavemadeallofthecorrections,theBuildingDirectorcanissuea certificateofoccupancy.YoumaynotoccupyadevelopmentuntiltheBuildingDirectorhasissuedacertificateof occupancy. INDEMNIFICATIONCONDITION InconsiderationbytheCityofBakersfieldforlanduseentitlements,includingbutnotlimitedtorelated environmentalapprovalsrelatedtoorarisingfromthisproject,theapplicant,and/orpropertyownerand/or subdividerΛͻ!ƦƦƌźĭğƓƷͼherein)agreestoindemnify,defend,andholdharmlesstheCityofBakersfield,itsofficers, agents,employees,departments,commissionersandboardsΛͻ/źƷǤͼherein)againstanyandallliability,claims, actions,causesofactionsordemandswhatsoeveragainstthem,oranyofthem,beforeadministrativeorjudicial tribunalsofanykindwhatsoever,inanywayarisingfrom,thetermsandprovisionsofthisapplication,including withoutlimitationanyCEQAapprovaloranyrelateddevelopmentapprovalsorconditionswhetherimposedby theCity,ornot,exceptfor/źƷǤ͸ƭsoleactivenegligenceorwillfulmisconduct. ThisindemnificationconditiondoesnotpreventtheApplicantfromchallenginganydecisionbytheCityrelatedto thisprojectandtheobligationsofthisconditionapplyregardlessofwhetheranyotherpermitsorentitlements areissued. TheCitywillpromptlynotifyApplicantofanysuchclaim,action,orproceeding,failingunderthisconditionwithin thirty(30)daysofactuallyreceivingsuchclaim.TheCity,initssolediscretion,shallbeallowedtochoosethe attorneyoroutsidelawfirmtodefendtheCityatthesolecostandexpenseoftheApplicantandtheCityisnot obligatedtouseanylawfirmorattorneychosenbyanotherentityorparty. REVISIONSTOTHEAPPROVEDPLAN Anytimeaftersiteplanapprovalbutbeforetheapprovalexpires,youmaysubmitrevisionstotheplan.Wewilltreat theserevisionsasanewsiteplanapplicationsubjecttoanewreviewandrequiredfees.ThePlanningDirectorcanonly approveminorchangestotheoriginalplanwithoutanewapplicationiftheyarenecessarytomeetacondition, mitigation,orresultfromphysicalobstaclesorothercomparableconstraints(SeeSection17.08.080.c.3oftheZoning Ordinance). EXPIRATIONOFPLANS Thissiteplanexpireson May9,2024(2yearsfromthedecisiondate),unlessbuildingpermitshavebeenissued,or wheretheusehascommencedonprojectsnotrequiringabuildingpermit.Theprojectmustbecompletedwithin5 yearsfromthedecisiondate.Ifthepropertyisrezoned,siteplanapprovalwillexpireupontheeffectivedateforthe rezoningunlesstheuseispermittedinthenewzone. ThePlanningDirectormayextendtheexpirationdateuptoone(1)yearifyouresubmitnewplansforcheckagainst thecoderequirementsineffectatthattimeandincludeawrittenrequestfortheextension.Wemustreceivethis request before expirationoftheprojectapproval.Wewillnotrequireafeeforthisextensionrequest;however, changestotheplansoriginallyapprovedforpurposesotherthancoderequirementsshallbesubjecttoanewsiteplan review,includingpaymentofallrequiredfees(SeeSection17.08.080.DoftheZoningOrdinance). ENVIRONMENTALDETERMINATION ThissiteplanreviewhasbeenfoundtobeexemptfromtheprovisionsoftheCaliforniaEnvironmentalQualityAct (CEQA)accordingtoSection15332.Thisprojectisexemptbecauseitisaninfilldevelopmentthatisconsistentwiththe generalplanandzoningregulations,iswithinanareapredominantlydevelopedwithurbanuses,isnotidentifiedas criticalhabitatforendangeredorthreatenedspecies,willnotsignificantlyaffecttrafficnoise,airorwaterquality,and willbeadequatelyservedbyappropriateutilitiesandpublicservices.ANoticeofExemptionhasbeenpreparedandis availableforreviewatthePlanningDivision. SPR220158Page|2of10 APPEAL Anypersonmayappealthisdecision.Anappealislimitedtowhetherornotanadopteddevelopmentstandard, zoningregulation,mitigation,orpolicyappliedornotappliedtotheproject,wasdoneconsistentwiththe authoritygrantedbycityordinancesortheCaliforniaEnvironmentalQualityAct(CEQA).Theappealmustbein ingtheprecisebasisorissueasnoted,mustincludetheappropriatefilingfee,andmustbefiledwithin writingstat 10days ofthedecisiondatetotheCityofBakersfieldPlanningCommission(c/oBakersfieldPlanningDirector, 1715ChesterAvenue,Bakersfield,CA93301).ThePlanningCommissionwillholdapublichearingontheappeal andtheirdecisionwillbefinalunlesstheirdecisionisappealedtotheCityCouncil. Siteplanapprovalisbasedonthestatementsmadeintheapplicationandtheplansyousubmitted.Anyerrorsor omissionsontheseplanscouldalterthecompliancelistand/orvoidthisdecision.Ifyouhavequestionsabout anyoftheitemsnotedintheSitePlanComplianceList,youmustspeaktothecontactpersonrepresentingthe departmentrequiringthatitem. Correspondencewillcontinuetobesenttotheapplicantonrecord.Shouldtheapplicantchange,itistheproperty ƚǞƓĻƩ͸ƭresponsibilitytoupdatethecontactinformationwiththePlanningDivision.Ifyouhaveotherquestions regardinggeneralinformationaboutthesiteplanreviewprocess,pleasecontactthePlanningDivisionat(661) 3263733. DECISIONDATE:May10,2022 Sincerely, LindaMitchell PrincipalPlanner 9ƓĭƌƚƭǒƩĻ cc:AllInterestedAgenciesΑForyourrecords. S:\\CounterOperations\\01_SPR\\2022\\220158_816PacificSt._2dwellings\\sprltr.docx SPR220158Page|3of10 CONDITIONSANDORDINANCECOMPLIANCE Thefollowingarespecificitemsthatyouneedtoresolvebeforeyoucanobtainabuildingpermitorbeallowed occupancy.Theseitemsincludeconditionsand/ormitigationrequiredbyprevioussiteentitlementapprovals (thesewillbespecificallynoted),changesoradditionsthatneedtobeshownonthefinalbuildingplans,alert youtospecificfees,andotherconditionsforyourprojecttosatisfythe/źƷǤ͸ƭdevelopmentstandards. Theitemslistedbelowwillusuallyneedtobeshownonthefinalbuildingplansorcompletedbeforeabuilding permitisissued.Aspartofthebuildingpermitsubmittal,identifythelocationofyourresponsebyusingthe !tt\[L/!b͸{RESPONSE lineprovideddirectlybelowtheitem(example:sheetnumber,detail,etc.). A.DEVELOPMENTSERVICESBUILDING(1715ChesterAvenue) (StaffcontactOscarFuentes;6613263676orOFuentes@bakersfieldcity.us) 1.Showonthefinalbuildingplanhowandwherewaterwillbedrainedfromtheproperty. !tt\[L/!b͸{RESPONSE:__________________________________________________________ 2.Thedevelopershallincludefireresistivewallconstructiondetailswiththefinalbuildingplansfor thatiswithinthedistanceassetforthinTable602oftheCalifornia allexteriorwallsofanybuilding BuildingCode. !tt\[L/!b͸{RESPONSE:__________________________________________________________ 3.Buildingsorstructuresshallrequireinstallationofanautomaticfiresprinklersystemwhere requiredbycurrentCaliforniaBuildingCodeandCityordinance. !tt\[L/!b͸{RESPONSE:__________________________________________________________ 4.TheBuildingDivisionwillcalculateandcollecttheappropriateschooldistrictimpactfeeatthe timetheyissueabuildingpermit. !tt\[L/!b͸{RESPONSE:__________________________________________________________ 5.FinalBuildingplansshallshowpedestrianaccesspathwaysoreasementsforpersonswith disabilitiesfrompublicrightsofwaysthatconnecttoallaccessiblebuildings,facilities,elements, accordancewiththeCaliforniaBuildingCode.Thesepedestrianaccesswaysshall andspacesin notbeparalleltovehicularlanesunlessseparatedbycurbsorrailings. !tt\[L/!b͸{RESPONSE:__________________________________________________________ SPR220158Page|4of10 6.Priortograntingoccupancy,theBuildingDivisionwillverifythatawatermeterservingthe developmentisinplace.Therefore,itisrecommendedthatthedevelopercontacttheapplicable waterpurveyortoinquireabouttheirprocessforobtainingwaterserviceforthedevelopmentas soonaspossible.Todeterminewho thewaterpurveyorforthedevelopmentis,youmaycontact theCityofBakersfieldWaterResourcesDepartment(1000BuenaVistaRoad,Bakersfield,CA, phone:6613263715). !tt\[L/!b͸{RESPONSE:__________________________________________________________ 7.Showonthefinalbuildingplan,electricvehiclesupplyequipmenttofacilitatefutureinstallation asrequiredbytheCaliforniaGreenCode. !tt\[L/!b͸{RESPONSE:__________________________________________________________ B.DEVELOPMENTSERVICESPLANNING(1715ChesterAvenue) (Staffcontact:PatStowe6613263679orPStowe@bakersfieldcity.us) 1.Theminimumparkingrequiredforthisprojecthasbeencomputedbasedonuseandshallbeas follows: ProposedParkingRequired UseArea(SF)RatioParking Existingdwellingunit936SF2perdwellingunit2spaces (2bedroomunit) 2dwellingunits587SFperunit1perdwellingunit2spaces (1bedroomunit) TotalRequiredParking:4spaces (Note:4 parkingspacesareshownontheproposedsiteplan.Byordinance,compactandtandem spacescannotbecountedtowardsmeetingminimumparkingrequirements.) !tt\[L/!b͸{RESPONSE:__________________________________________________________ 2.Minimumparkingstalldimensionsshallbe9feetwideby18feetlongandshallbedesigned accordingtostandardsestablishedbytheTrafficEngineer.Vehiclesmayhangoverlandscape areasnomorethan21/2feetprovidedrequiredsetbacksalongstreetfrontagesaremaintained, andtreesandshrubsareprotectedfromvehicles. !tt\[L/!b͸{RESPONSE:__________________________________________________________ 3.Allparkinglots,driveways,driveaisles,loadingareas,andothervehicularaccessways,shallbe pavedwithconcrete,asphalticconcrete,orotherpavedstreetsurfacingmaterialinaccordance withtheBakersfieldMunicipalCode(Sections15.76.020and17.58.060.A.). SPR220158Page|5of10 !tt\[L/!b͸{RESPONSE:__________________________________________________________ 4.Thedevelopershallincludeafinallandscapeplanwitheachsetofthebuildingplanssubmittedto theBuildingDivision.BuildingpermitswillnotbeissueduntilthePlanningDivisionhasapproved thefinallandscapeplanforconsistencywithapprovedsiteplansandminimumordinance standards.PleaserefertothelandscapingrequirementsinChapter17.61.Landscapeplansshall include,butarenotlimitedto,dataon:gallon/boxsize,spacing,species(referenceapproved parkinglottreelist),ratioofdeciduousvs.evergreen,shadecalculations,groundcover calculations,etc. (Note1:Atthetimeafinalsiteinspectionisconducted,itisexpectedthatplantswillmatchthe speciesidentifiedandbeinstalledinthelocationsconsistentwiththeapprovedlandscapeplan. ChangesmadewithoutpriorapprovalofthePlanningstaffmayresultintheremovaland/or relocationof installedplantmaterialsanddelaysinobtainingbuildingoccupancy.) (Note2:NomaturelandscapingshallberemovedwithoutpriorapprovalbythePlanning Director.) (Note3:Uponapprovalofthefinallandscapeplan,adigitalcopyshallbesubmittedtothe Planningstaffcontactlistedabove.) !tt\[L/!b͸{RESPONSE:__________________________________________________________ 5.Asolidmasonrywallshallbeconstructedadjacenttoresidentiallyzonedand/ordesignated property.Thiswallmustbeshownonthefinalbuildingplansandshallbeconstructedaminimum heightof6feetasmeasuredfromthehighestadjacentfinishedpropertygrade.Iftheparkinglot, includingdriveaisles,deliveryareas,loadingandunloadingareasarewithin10feetof residentiallyzonedproperty,a7footwidelandscapestripthatincludeslandscapingconsistent withChapter17.61shallbeinstalledbetweenthewallandparking/driveareas. !tt\[L/!b͸{RESPONSE:__________________________________________________________ 6.Streetaddressesfortheprojectshallbedesignatedbystaff.Thesenumberswillbetheonly addressesassignedbythecityunlessyouwishtohaveadifferentaddressprogram.Please contactKarlDavissonat6613263594forfurtherinformation. !tt\[L/!b͸{RESPONSE:__________________________________________________________ 7.AParkDevelopmentandImprovementFeeshallbepaidatthetimeofthebuildingpermitbeing issuedforeachindependentresidentialunit.Wewillbasethefeeattherateineffectatthetime thepermitisissued. !tt\[L/!b͸{RESPONSE:__________________________________________________________ 8.Refusecollectionbinenclosuresandcontainerareasaresubjecttoallrequiredstructuralsetback fromstreetfrontages,andshallnotreduceanyparking,loadingorlandscapingareasasrequired bytheZoningOrdinance. SPR220158Page|6of10 !tt\[L/!b͸{RESPONSE:__________________________________________________________ 9.Priortoreceivingfinalbuildingorsiteoccupancy,youmustcontactthePlanningDivision(staff contactnotedabove)forfinalinspectionandapprovalofthelandscaping,parkinglot,lightingand otherrelatedsiteimprovements.Inspectionswillnotbeconducteduntilallrequireditemshave beeninstalled.AnydeviationsfromtheapprovedplanswithoutpriorapprovalfromthePlanning Divisionmayresultinreconstructionanddelaysinobtainingabuildingorsiteoccupancy. !tt\[L/!b͸{RESPONSE:__________________________________________________________ C.FIREDEPARTMENT(2101HStreet) (StaffcontactErnieMedina;6613263682orEMedina@bakersfieldfire.us) 1.Showonthefinalbuildingplansthefollowingitems: a.Allfirehydrants,bothoffsite(nearesttosite)andonsite.LƓĭƌǒķĻŅƌƚǞķğƷğƚƓğƌƌ ŷǤķƩğƓƷƭ͵Hydrantsshallbeingoodworkingconditionandaresubjecttotestingfor verification.Fireflowrequirementsmustbemetpriortoconstructioncommencingon theprojectsite.Pleaseprovidetwo(2)setsofthewaterplansstampedbyalicensed RegisteredCivilEngineertotheFireDepartmentandtwo(2)setstotheWaterResources Department(1000BuenaVistaRoad,Bakersfield,CA.93311;6613263715). (Note:Show:1)distancetothenearesthydrant;and2)distancefromthathydranttothe farthestpointoftheprojectsite.) b.Allfiresprinklerand/orstandpipesystems,firealarmsandcommercialhoodsystems. ThesesuppressionsystemsrequirereviewandpermitsbytheFireDepartment.TheFire Departmentwillissueguidelinesforthesevariousitemsastheymayapplytothisproject. !tt\[L/!b͸{RESPONSE:__________________________________________________________ D.WATERRESOURCES(1000BuenaVistaRoad) (StaffcontactΑTylorHester;6613263009orTHester@bakersfieldcity.us) 1.Atthistime,therearenoapplicableconditionsfortheproposedproject.Conditionsmaybe addediftheprojectchanges. E.PUBLICWORKSENGINEERING(1501TruxtunAvenue) (StaffcontactΑSusannaKormendi;6613263997orskormendi@bakersfieldcity.us) 1.Showonthefinalbuildingplansallexistingconnection(s)tothepublicsewersystem. !tt\[L/!b͸{RESPONSE:__________________________________________________________ SPR220158Page|7of10 2.Allonsiteareasrequiredtobepaved(i.e.,parkinglots,accessdrives,loadingareas,etc.)shall consistofconcrete,asphalticconcrete(TypeB.A.C.)orotherpavedstreetmaterialapprovedby theCityEngineer.Pavementshallbeaminimumthicknessof2inchesover3inchesofapproved basematerial(i.e.,ClassIIA.B.)ifconcreteisused,itshallbeaminimumthicknessof4inchesper MunicipalCodeSection17.58.060.A.Thispavingstandardshallbenotedonthefinalbuilding planssubmittedtotheBuildingDivisionbeforeanybuildingpermitswillbeissued. !tt\[L/!b͸{RESPONSE:__________________________________________________________ 3.IfagradingplanisrequiredbytheBuildingDivision,buildingpermitswillnotbeissueduntilthe gradingplanisapprovedby both thePublicWorksDepartmentandtheBuildingDivision. !tt\[L/!b͸{RESPONSE:__________________________________________________________ 4.Allstormwatergeneratedontheprojectsite,includingthestreetfrontageshallberetainedonsite unlessotherwiseallowedbythePublicWorksDepartment(pleasecontactthePublicWorks DepartmentΑSubdivisionsat6613263576). !tt\[L/!b͸{RESPONSE:__________________________________________________________ 5.Priortosubmittingrevisedplans,pleasecontacttheConstructionSuperintendentat661326 3049toscheduleasiteinspectiontofindoutwhatimprovementsmayberequired.Beforeany buildingorsitecanbeoccupied,thedevelopermustreconstructorrepairsubstandardoffsite streetimprovementsthatfrontthesitetoadoptedcitystandardsasdirectedbytheCityEngineer. Additionally,anyoffsite/frontageimprovementsorrepairsrequiredduringthesiteinspection shallbeshownonthegradingplanorfinalbuildingplan. !tt\[L/!b͸{RESPONSE:__________________________________________________________ 6.AstreetpermitfromthePublicWorksDepartmentshallbeobtainedbeforeanyworkcanbedone withinthepublicrightofway(streets,alleys,easements).Pleaseincludeacopyofthissiteplan reviewdecisiontothedepartmentatthetimeyouapplyforthispermit. !tt\[L/!b͸{RESPONSE:__________________________________________________________ 7.Asewerconnectionfeeshallbepaidatthetimeabuildingpermitisissued.Wewillbasethisfee attherateineffectatthetimeabuildingpermitisissued. !tt\[L/!b͸{RESPONSE:__________________________________________________________ 8.IftheprojectissubjecttotheprovisionsoftheNationalPollutantDischargeEliminationSystem (NPDES),aͻbƚƷźĭĻofLƓƷĻƓƷͼ(NOI)tocomplywiththetermsoftheGeneralPermittoDischarge StormWaterAssociatedwithConstructionActivity(SWRCBOrderNo.2009009DWQas amendedbyOrderNo.20100014DWQand20120006DWQ)mustbefiledwiththeStateWater ResourcesControlBoardinSacramentobeforethebeginningofanyconstructionactivity. CompliancewiththegeneralpermitrequiredthataStormWaterPollutionPreventionPlan SPR220158Page|8of10 (SWPPP)beprepared,continuouslycarriedout,andalwaysbeavailableforpublicinspection duringnormalconstructionhours. !tt\[L/!b͸{RESPONSE:__________________________________________________________ 9.Priortotheissuanceofeachbuildingpermit,orifnobuildingpermitisrequired,thefirstrequired Cityapprovalpriortoconstruction,thedeveloper/ownershallpayaTransportationImpactFee (TIF)forregionalfacilities.Thisfeewillbebasedontherateineffectatthetimetheapplicable approvalisissuedorinaccordancewiththeSubdivisionMapAct,asapplicable.ThePublicWorks Departmentwillcalculateanestimateofthetotalfeeuponsubmittalofconstructionplansfor theproject. !tt\[L/!b͸{RESPONSE:__________________________________________________________ 10.ThedevelopershallformanewMaintenanceDistrict.Undevelopedparcelswithinanexisting MaintenanceDistrictarerequiredtoupdateMaintenanceDistrictdocuments.Updated documents,includingProposition218BallotandCovenant,shallbesignedandnotarized.Ifthere arequestions,contactAdamCorderoat6613263576. (Note:Ifalreadywithinamaintenancedistrict,mayneedtoupdatethemaintenancedistrict form.) !tt\[L/!b͸{RESPONSE:__________________________________________________________ F.PUBLICWORKSTRAFFIC(1501TruxtunAvenue) (StaffcontactΑSusannaKormendi;6613263997orskormendi@bakersfieldcity.us) 1.Atthistime,noapplicableconditionsfortheproposedproject.Conditionsmaybeaddedifthe projectchanges. G.PUBLICWORKSSOLIDWASTE(4101TruxtunAvenue) (StaffContactRichardGutierrez:rmgutierrez@bakersfieldcity.us) 1.Youmustcontactthestaffpersonnotedabovebeforebuildingpermitscanbeissuedorwork beginsonthepropertytoestablishthelevelandtypeofservicenecessaryforthecollectionof refuseand/orrecycledmaterials.Collectionlocationsmustprovideenoughcontainmentareafor therefusethatisgeneratedwithoutviolatingrequiredzoningorsetbackrestrictions(seePlanning Divisionconditions).Levelsofservicearebasedonhowoftencollectionoccursasfollows: Cartservice1cubicyard/weekorless1timeperweek Frontloaderbinservices1cubicyard/week12cubicyards/day RolloffcompactorserviceMorethan12cubicyards/day !tt\[L/!b͸{RESPONSE:__________________________________________________________ SPR220158Page|9of10 2.Facilitiesthatrequireinfectiouswasteservicesshallobtainapprovalforseparateinfectiouswaste storageareasfromtheKernCountyHealthDepartment.Innoinstancesshalltherefusebinarea beusedforinfectiouswastecontainmentpurposes. !tt\[L/!b͸{RESPONSE:__________________________________________________________ 3.Residentialpropertieswithfour(4)unitsorgreaterandare requiredtohaveADAAccessible unit/s,mustproviderefuse/recyclingenclosuresthatareADAAccessible(Detail#ST29). !tt\[L/!b͸{RESPONSE:__________________________________________________________ 4.Residentialpropertieswiththree(3)unitsorlesswillbeservicedwithautomatedcarts.Every dwellingunitmusthaveitsowncartandnomorethanthree(3)cartswillbeallowedforeach parcel.AscreenedЌ͸xВ͸concreterefusecartstoragepadmustbeprovidedforcartswhenthey arenotoutforcollection(thisareashallbeclearlyshownonthefinalbuildingplans).TheSolid WasteDivisionwilldeterminewhereservicecollectionwilloccur(streetcurbsideoralley). !tt\[L/!b͸{RESPONSE:__________________________________________________________ 5.Facilitieswithexistingrefuseservicemustimprovetheservicelocationarea(s)accordingto adoptedCitystandards(Detail#ST27andST29B).Theseimprovementsshallbeclearlyshown onthefinalbuildingplans. !tt\[L/!b͸{RESPONSE:__________________________________________________________ enclosuredesign,theyshallnotinterferewithspaceprovided 6.Ifutilitiesareincorporatedintothe forrefusebinsandmustprovidesufficientprotectionmeasurestoguardtheutilitiesfrom damage. !tt\[L/!b͸{RESPONSE:__________________________________________________________ 7.Enclosuresshallnotbelocatedinanareathatwouldcauserefusetruckstointerferewithdrive thrutrafficflowenteringorexitingthesite,drivethrulanes,etc. !tt\[L/!b͸{RESPONSE:__________________________________________________________ SPR220158Page|10of10