Loading...
HomeMy WebLinkAbout2022-04-25 Electronic FMC After Cold StartAppendix VI Underground Storage Tank Monitoring System Certification Form CERS = California Environmental Reporting System, GPH = Gallons Per Hour, ID = Identification, ICC = International Code Council, LLD = Line Leak Detector, NA = Not Applicable, SW = Single- Walled, UDC = Under-Dispenser Containment, UST = Underground Storage Tank, VPH = Vacuum/Pressure/Hydrostatic Page 1 of 6 TYPE OF ACTION ܆܆ Installation ܆ Repair ܆ 12 Month 1. FACILITY INFORMATION CERS ID Certification Date Facility Name Facility Address City ZIP Code 2. SERVICE TECHNICIAN INFORMATION Company Performing the Certification Phone Mailing Address Service Technician Performing Test Contractor/Tank Tester License Number ICC Number ICC Expiration Date 3. TRAINING AND CERTIFICATIONS Manufacturer and Test Equipment Training Certifications Expiration Date 4. CERTIFICATION BY SERVICE TECHNICIAN CONDUCTING TEST I hereby certify that the monitoring system is operational in accordance with California Code of Regulations, title 23, division 3, chapter 16, section 2638; that required supporting documentation is attached; and all information contained herein is accurate. Service Technician Signature Date Total # of Pages 10023037 04/25/2022 Jaco #3347 Fastrip#26 2698 Oswell St Bakersfield, Ca 93306 Nwestco LLC (800) 339-9930 2209 Zeus Court, Bakersfield, CA 93308 Jason Woods 1073967 8492093 03/23/2023 Veeder Root C26937 07/26/2023 04/25/2022 6 Underground Storage Tank Monitoring System Certification Form Page 2 of 6 5. MONITORING SYSTEM AND PROGRAMMING A separate Monitoring System Certification Form must be prepared for each control panel. Make of Monitoring System Control Panel Model of Monitoring System Control Panel Software Version Installed Attach the post-certification reports if the monitoring system is capable of generating either; ܆܆Monitoring System Set-up ܆܆ Alarm History Report Yes No NA All monitoring equipment is operational per manufacturer’s specifications? ܆܆܆܆ Secondary containment systems are free of damage, debris, or liquid? ܆܆܆܆ Are the audible and visual alarms operational? ܆܆܆܆ All sensors have been: 1) visually inspected for wiring kinks, breaks and residual buildup on floats; and 2) tested for functionality and confirmed operational? ܆܆܆܆܆܆ Are all sensors installed to detect a release at the earliest opportunity in the secondary containment? ܆܆܆܆܆܆ The monitoring system set-up was reviewed, and proper settings confirmed? ܆܆܆܆܆܆ Was the monitoring control panel’s backup battery visually inspected, functionally tested, and confirmed operational? ܆܆܆܆܆܆ Does the flow of fuel stop at the dispenser if a release is detected in the under- dispenser containment? ܆܆܆܆܆܆ Does the turbine automatically shut down if the piping secondary containment monitoring system fails to operate or is electrically disconnected? ܆܆܆܆܆܆ Does the turbine automatically shut down if the piping secondary containment monitoring system detects a release? Which sensors initiate positive shut down? (Check all that apply) ܆ Sump ܆ UDC ܆܆܆܆܆܆ If monitoring system alarms are relayed to a remote monitoring center, is all communication equipment operational? ܆܆܆܆܆܆ Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 Gilbarco EMC 330.01 Underground Storage Tank Monitoring System Certification Form Page 3 of 6 6. SENSOR TESTING RESULTS List only sensors tested on date of this certification. List “Sensor ID” as labeled in system programming. Additional copies of this page may be attached to accommodate all sensors tested. Sensor ID Sensor Model Component(s) Monitored Pass Fail ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 L1 794380-208 Unleaded 1 STP L2 794380-420 Unleaded 1 Annular L3 794380-208 DSL STP L4 794380-420 DSL Annular L6 794380-420 Premium Annular L7 794380-208 Unleaded 2 STP L8 794380-420 Unleaded 2 Annular L9 794380-208 Dispenser 1/2 L10 794380-208 Dispenser 3/4 L11 794380-208 Dispenser 5/6 L12 794380-208 Dispenser 7/8 L13 794380-208 Trans Sump North L14 794380-208 Trans Sump South L15 794380-208 Premium STP Underground Storage Tank Monitoring System Certification Form Page 4 of 6 7. LINE LEAK DETECTOR TESTING ܆܆ Check this box if line leak detectors ARE NOT installed. (Do not complete this section.) Simulated release rate verified: (Check all that apply.) ܆܆ 3 GPH ܆܆ 0.1 GPH ܆܆ 0.2 GPH Yes No NA Has the testing apparatus been properly calibrated? ܆܆ ܆܆ ܆܆ For emergency generator tank systems, does the LLD create an audible and visual alarm when a leak is detected? ܆܆ ܆܆ ܆܆ For mechanical LLDs, does the LLD restrict the flow through the pipe when a release is detected? ܆܆ ܆܆ ܆܆ For electronic LLDs, does the turbine automatically shut off when a release is detected? ܆܆ ܆܆ ܆܆ For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system is disabled or disconnected? ܆܆ ܆܆ ܆܆ For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system malfunctions or fails a tightness test? ܆܆ ܆܆ ܆܆ For electronic LLDs, have all accessible wiring connections been visually inspected for kinks and breaks? ܆܆ ܆܆ ܆܆ Were all items on the equipment manufacturer’s maintenance checklist completed? ܆܆ ܆܆ ܆܆ Were all LLDs confirmed operational within regulatory requirements? ܆܆ ܆܆ ܆܆ LLD ID LLD Model Lines Monitored Pass Fail ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ Describe all answers marked “No” or “Fail” and proposed remedy in Section 9. List all monitoring equipment either replaced or repaired in Section 9 T1/T4 87 FX1V T2 DSL FX1DV T3 PNL FX1V Underground Storage Tank Monitoring System Certification Form Page 5 of 6 8. IN-TANK GAUGING TESTING ܆܆ Check this box if tank gauging is used only for inventory control. ܆܆ Check this box if NO tank gauging equipment is installed. (Do not complete this section if either box is checked.) Yes No NA All wiring has been: 1) visually inspected for kinks, breaks and proper entry and termination; and 2) tested for ground faults? ܆܆ ܆܆ ܆܆ Were all in-tank gauging probes visually inspected for damage and residue buildup to ensure that floats move freely, functionally tested, and confirmed operational? ܆܆ ܆܆ Was accuracy of system’s product level readings tested? ܆܆ ܆܆ ܆܆ Was accuracy of system’s water level readings tested? ܆܆ ܆܆ ܆܆ Were all probes reinstalled properly? ܆܆ ܆܆ ܆܆ Were all items on the equipment manufacturer’s maintenance checklist completed? ܆܆ ܆܆ ܆܆ Probe ID Probe Model Tanks Monitored Pass Fail ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ ܆܆ 9. COMMENTS Describe all answers marked “No” or “Fail” and proposed remedy. List all monitoring equipment either replaced or repaired. ܆܆ Underground Storage Tank Monitoring System Certification Form Page 6 of 6 10. MONITORING SITE PLAN Date site plan was prepared: If a site plan has been prepared that shows all required information, you may include it, rather than this page, with your Monitoring System Certification Form. The site plan must show the general layout of tanks and identify locations of the monitoring panel, and all leak detection equipment and monitoring locations. Include a legend for all symbols depicted. PRICE SIG N NOPARKING EXISTING BUILDING G H CATCHBASIN W W SLOPE RETAINING WALL DRAINAGE WAY SLOPE AL6AL4AL2AL8 F V F V F V F12,000 GALLONPREMIUM12,000 GALLONDEISEL12,000 GALLON87-1 UNLEADED12,000 GALLON87-2 UNLEADEDSTPL7STPL1STPL3STPL15L10 34L912L13L1278L1156L14N AUBURN ST. PROPERTY LINE OSWELL ST.DUMPSTERCOLUMN SUPPORTINGRESTAURANT SIGN (2x) STORAGE CONTAINER LEGEND L1 87-1 STP L2 87-1 ANNULAR L3 DSL STP L4 DSL ANNULAR L6 91 ANNULAR L7 87-2 STP L8 87-2 ANNULAR L9 UDC 1 - 2 L10 UDC 3 - 4 L11 UDC 5 - 6 L12 UDC 7 - 8 L13 N TRANS SUMP L14 S TRANS SUMP L15 91 STP 87 GAS 3/2 INCH DBL WALLED PIPE 91 GAS 3/2 INCH DBL WALLED PIPE DIESEL 3/2 INCH DBL WALLED PIPE VAPOR RETURN 3 AND 2 INCH SINGLE WALL PIPE VAPOR VENT 2 INCH SINGLE WALLED PIPE PRODUCT SPILL CONTAINER VAPOR SPILL CONTAINER ANNULAR EMERGENCY SHUT-OFF OVERFILL ALARM FIRE EXTINGUISHER GAS METER SHUT-OFF WATER METER SHUT-SHUT OFF HEALY CAS EVACUATION MEETING POINT AUTOMATIC TANK GUAGE CIRCUIT BREAKER UST ELECTRICAL PANEL AIR AND WATER HAZ-WASTE DRUM W G A H P V SCALE: SITE MAP C1 VICINITY MAP PROJECT DATA 1"=10'-0" INCHES012 SHEET SIZE 22 X 34 2698 OSWELL ST. BAKERSFIELD, CA 93306 PROJECT OWNER: JACO HILL PO. BOX 82515 BAKERSFIELD, CA 93380 CONTACT: SITE PLOT PLAN FOR: FACILITY ID: 15-021-00300 CERS ID 10023037 FASTRIP #3347 2698 OSWELL ST. BAKERSFIELD, CA 93306 01/10/17 REV.OSWELL ST.HWY 178 Jaco #3347 Setup, Alarm History Before. Responses Received: 200 FASTRIP 347 2698 OSWELL ST BAKERSFIELD 93306 661-872-8721 APR 25, 2022 12:10 PM TANK PRODUCT GALLONS INCHES WATER DEG F ULLAGE 1 UNL 1 8778 65.88 0.0 64.9 3222 2 DIESEL 3901 34.64 0.8 69.7 8099 3 PNL 7179 55.44 0.0 68.3 4821 4 UNL 2 9036 67.64 0.7 64.1 2964 I90500 APR 25, 2022 12:10 PM SOFTWARE REVISION LEVEL VERSION 330.01 SOFTWARE# 346330-100-B CREATED - 10.07.23.17.25 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD I50500 APR 25, 2022 12:10 PM SYSTEM TYPE AND LANGUAGE FLAG SYSTEM UNITS U.S. SYSTEM LANGUAGE ENGLISH SYSTEM DATE/TIME FORMAT MON DD YYYY HH:MM:SS xM I50201 APR 25, 2022 12:10 PM SHIFT TIME 1 : 6:00 AM I50202 APR 25, 2022 12:10 PM SHIFT TIME 2 : DISABLED I50203 APR 25, 2022 12:10 PM SHIFT TIME 3 : DISABLED I50204 APR 25, 2022 12:10 PM SHIFT TIME 4 : DISABLED I54600 APR 25, 2022 12:10 PM TANK PER TST NEEDED WRN: DISABLED I54900 APR 25, 2022 12:10 PM TANK ANN TST NEEDED WRN: DISABLED I55300 APR 25, 2022 12:10 PM LINE RE-ENABLE METHOD PASS LINE TEST I55600 APR 25, 2022 12:10 PM LINE PER TST NEEDED WRN: DISABLED I55900 APR 25, 2022 12:10 PM LINE ANN TST NEEDED WRN: DISABLED I50D00 APR 25, 2022 12:10 PM PRINT TC VOLUMES ENABLED I50E00 APR 25, 2022 12:10 PM TEMP COMPENSATION VALUE (DEG F ): 60.0 I60B00 APR 25, 2022 12:10 PM STICK HEIGHT OFFSET ENABLE STATUS DISABLED I51400 APR 25, 2022 12:10 PM H-PROTOCOL DATA FORMAT HEIGHT I51A01 APR 25, 2022 12:10 PM DAYLIGHT SAVING TIME ENABLED ON I51B00 APR 25, 2022 12:10 PM DAYLIGHT SAVING TIME START DATE MAR WEEK 2 SUN 2:00 AM END DATE NOV WEEK 1 SUN 2:00 AM I51600 APR 25, 2022 12:10 PM RE-DIRECT LOCAL PRINTOUT DISABLED I50400 APR 25, 2022 12:10 PM 232 SECURITY CODE PORT SECURITY CODE STATUS 1 000000 DISABLED 2 000000 DISABLED 3 000000 DISABLED 4 000000 DISABLED 5 000000 DISABLED 6 000000 DISABLED I21900 APR 25, 2022 12:10 PM TANK CHART SECURITY DISABLED I5BD00 APR 25, 2022 12:10 PM CUSTOM ALARM LABELS DISABLED I56000 APR 25, 2022 12:10 PM MASS/DENSITY DISABLED I88101 APR 25, 2022 12:10 PM PORT SETTINGS: COMM BOARD : 1 (EDIM ) RS-232 SECURITY CODE : DISABLED I88102 APR 25, 2022 12:10 PM PORT SETTINGS: COMM BOARD : 2 (RS-232) BAUD RATE : 9600 PARITY : NONE STOP BIT : 1 STOP DATA LENGTH: 8 DATA RS-232 SECURITY CODE : DISABLED I88103 APR 25, 2022 12:10 PM PORT SETTINGS: COMM BOARD : 3 (RS-232) BAUD RATE : 9600 PARITY : NONE STOP BIT : 1 STOP DATA LENGTH: 8 DATA RS-232 SECURITY CODE : DISABLED I88104 APR 25, 2022 12:10 PM I88105 APR 25, 2022 12:10 PM I88106 APR 25, 2022 12:10 PM I52000 APR 25, 2022 12:10 PM RECEIVER AUTO DIAL TYPE & START TIME RCVR LOCATION LABEL DIAL TYPE START TIME 1 ON DATE ??? 25, 2022 DISABLED 2 ON DATE ??? 25, 2022 DISABLED 3 ON DATE ??? 25, 2022 DISABLED 4 ON DATE ??? 25, 2022 DISABLED 5 ON DATE ??? 25, 2022 DISABLED 6 ON DATE ??? 25, 2022 DISABLED 7 ON DATE ??? 25, 2022 DISABLED 8 ON DATE ??? 25, 2022 DISABLED I60100 APR 25, 2022 12:10 PM TANK CONFIGURATION DEVICE LABEL CONFIGURED 1 UNL 1 ON 2 DIESEL ON 3 PNL ON 4 UNL 2 ON I60200 APR 25, 2022 12:10 PM TANK PRODUCT LABEL TANK PRODUCT LABEL 1 UNL 1 2 DIESEL 3 PNL 4 UNL 2 I60300 APR 25, 2022 12:10 PM TANK PRODUCT CODE TANK PRODUCT LABEL 1 UNL 1 1 2 DIESEL 2 3 PNL 3 4 UNL 2 4 I60900 APR 25, 2022 12:10 PM TANK THERMAL COEFFICIENT TANK PRODUCT LABEL 1 UNL 1 0.000700 2 DIESEL 0.000450 3 PNL 0.000700 4 UNL 2 0.000700 I60700 APR 25, 2022 12:10 PM TANK DIAMETER TANK PRODUCT LABEL INCHES 1 UNL 1 96.00 2 DIESEL 96.00 3 PNL 96.00 4 UNL 2 96.00 I60A00 APR 25, 2022 12:10 PM TANK FULL VOLUME TANK PRODUCT LABEL TANK PROFILE GALLONS 1 UNL 1 1 PT 12000 2 DIESEL 1 PT 12000 3 PNL 1 PT 12000 4 UNL 2 1 PT 12000 I60400 APR 25, 2022 12:10 PM TANK FULL VOLUME TANK PRODUCT LABEL GALLONS 1 UNL 1 12000 2 DIESEL 12000 3 PNL 12000 4 UNL 2 12000 I60500 APR 25, 2022 12:10 PM TANK 4 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 UNL 1 12000 0 0 0 2 DIESEL 12000 0 0 0 3 PNL 12000 0 0 0 4 UNL 2 12000 0 0 0 I60600 APR 25, 2022 12:10 PM TANK 20 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 UNL 1 12000 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 DIESEL 12000 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3 PNL 12000 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4 UNL 2 12000 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 I61500 APR 25, 2022 12:10 PM TANK PRODUCT LABEL METER DATA 1 UNL 1 NO 2 DIESEL NO 3 PNL NO 4 UNL 2 NO I62F00 APR 25, 2022 12:10 PM MAG PROBE FLOAT SIZE TANK PRODUCT LABEL FLOAT SIZE: 1 UNL 1 4.0 IN. 2 DIESEL 4.0 IN. 3 PNL 4.0 IN. 4 UNL 2 3.0 IN. I62700 APR 25, 2022 12:10 PM TANK HIGH WATER WARNING LIMIT TANK PRODUCT LABEL INCHES 1 UNL 1 2.0 2 DIESEL 2.0 3 PNL 2.0 4 UNL 2 2.0 9999FF1B I62400 APR 25, 2022 12:10 PM TANK HIGH WATER LEVEL LIMIT TANK PRODUCT LABEL INCHES 1 UNL 1 3.0 2 DIESEL 3.0 3 PNL 3.0 4 UNL 2 3.0 I62800 APR 25, 2022 12:10 PM TANK MAXIMUM VOLUME LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 1 12000 2 DIESEL 12000 3 PNL 12000 4 UNL 2 12000 I62300 APR 25, 2022 12:10 PM TANK OVERFILL LEVEL LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 1 10800 2 DIESEL 10800 3 PNL 10800 4 UNL 2 10800 I62200 APR 25, 2022 12:10 PM TANK HIGH PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 1 11400 2 DIESEL 11400 3 PNL 11400 4 UNL 2 11400 I62900 APR 25, 2022 12:10 PM TANK DELIVERY REQUIRED LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 1 1200 2 DIESEL 1200 3 PNL 1200 4 UNL 2 1200 I62100 APR 25, 2022 12:10 PM TANK LOW PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 1 1200 2 DIESEL 1200 3 PNL 1200 4 UNL 2 1200 I62600 APR 25, 2022 12:10 PM TANK LEAK ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 1 99 2 DIESEL 99 3 PNL 99 4 UNL 2 99 I62500 APR 25, 2022 12:10 PM TANK SUDDEN LOSS LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 1 99 2 DIESEL 99 3 PNL 99 4 UNL 2 99 I60800 APR 25, 2022 12:10 PM TANK TILT TANK PRODUCT LABEL INCHES 1 UNL 1 0.00 2 DIESEL 0.00 3 PNL 0.00 4 UNL 2 0.00 I60B00 APR 25, 2022 12:10 PM STICK HEIGHT OFFSET ENABLE STATUS DISABLED I60C00 APR 25, 2022 12:10 PM TANK STICK HEIGHT OFFSET TANK PRODUCT LABEL INCHES 1 UNL 1 0.00 2 DIESEL 0.00 3 PNL 0.00 4 UNL 2 0.00 I61200 APR 25, 2022 12:10 PM TANK MANIFOLDED PARTNERS TANK PRODUCT LABEL SIPHON MANIFOLDED TANKS LINE MANIFOLDED TANKS 1 UNL 1 4 NONE 2 DIESEL NONE NONE 3 PNL NONE NONE 4 UNL 2 1 NONE I63600 APR 25, 2022 12:10 PM PERIODIC LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 UNL 1 120 2 DIESEL 120 3 PNL 120 4 UNL 2 120 I62A00 APR 25, 2022 12:10 PM ANNUAL LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 UNL 1 0 2 DIESEL 0 3 PNL 0 4 UNL 2 0 I62C00 APR 25, 2022 12:10 PM TANK PERIODIC TEST TYPE TANK PRODUCT LABEL PERIODIC TEST TYPE 1 UNL 1 STANDARD 2 DIESEL STANDARD 3 PNL STANDARD 4 UNL 2 STANDARD I62D00 APR 25, 2022 12:10 PM TANK LEAK TEST FAIL ALARMS TANK PRODUCT LABEL 1 UNL 1 GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED 2 DIESEL GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED 3 PNL GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED 4 UNL 2 GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED I63100 APR 25, 2022 12:10 PM TANK LEAK TEST AVERAGING TANK PRODUCT LABEL ANNUAL PERIODIC 1 UNL 1 OFF OFF 2 DIESEL OFF OFF 3 PNL OFF OFF 4 UNL 2 OFF OFF I63000 APR 25, 2022 12:10 PM IN-TANK LEAK TEST NOTIFY TANK PRODUCT LABEL TANK TEST NOTIFY: 1 UNL 1 OFF 2 DIESEL OFF 3 PNL OFF 4 UNL 2 OFF I63200 APR 25, 2022 12:10 PM TANK TEST SIPHON BREAK TANK PRODUCT LABEL SIPHON BREAK 1 UNL 1 OFF 2 DIESEL OFF 3 PNL OFF 4 UNL 2 OFF I61000 APR 25, 2022 12:10 PM TANK DELIVERY DELAY TANK PRODUCT LABEL 1 UNL 1 1 2 DIESEL 1 3 PNL 1 4 UNL 2 1 I63A00 APR 25, 2022 12:10 PM LOW LEVEL PUMP THRESHOLD FOR SEQUENTIAL LINE MANIFOLD TANK PRODUCT LABEL PUMP THRESHOLD 1 UNL 1 10.00% 2 DIESEL 10.00% 3 PNL 10.00% 4 UNL 2 10.00% I61100 APR 25, 2022 12:10 PM LEAK TEST METHOD - - - - - - - - - - - - TEST ON DATE : ALL TANK JUL 23, 2010 START TIME : DISABLED TEST RATE :0.20 GAL/HR DURATION : 2 HOURS TST EARLY STOP:DISABLED I61300 APR 25, 2022 12:10 PM CSLD PROBABLITY OF DETECTION I61400 APR 25, 2022 12:10 PM CSLD CLIMATE FACTOR I61600 APR 25, 2022 12:10 PM TANK PRODUCT LABEL CAL UPDATE 1 UNL 1 IMMEDIATE 2 DIESEL IMMEDIATE 3 PNL IMMEDIATE 4 UNL 2 IMMEDIATE I61A00 APR 25, 2022 12:10 PM IN-TANK LEAK TEST EARLY STOP TANK PRODUCT LABEL TST EARLY STOP: 1 UNL 1 DISABLED 2 DIESEL DISABLED 3 PNL DISABLED 4 UNL 2 DISABLED I61B00 APR 25, 2022 12:10 PM IN-TANK LEAK GROSS TEST AUTO-CONFIRM I61C00 APR 25, 2022 12:10 PM CSLD REPORT ONLY I62B00 APR 25, 2022 12:10 PM TANK LAST ANNUAL TEST TANK PRODUCT LABEL DATE 1 UNL 1 ??? 0, 0 2 DIESEL ??? 0, 0 3 PNL ??? 0, 0 4 UNL 2 ??? 0, 0 I63300 APR 25, 2022 12:10 PM LEAK TEST REPORT FORMAT: NORMAL I63400 APR 25, 2022 12:10 PM RECONCILIATION WARNING LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 1 0 2 DIESEL 0 3 PNL 0 4 UNL 2 0 I63500 APR 25, 2022 12:10 PM RECONCILIATION ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 1 1 2 DIESEL 1 3 PNL 1 4 UNL 2 1 I63900 APR 25, 2022 12:10 PM ACCU CHART END SHAPE FACTOR TANK PRODUCT LABEL 1 UNL 1 END FACTOR: NONE 2 DIESEL END FACTOR: NONE 3 PNL END FACTOR: NONE 4 UNL 2 END FACTOR: NONE I78000 APR 25, 2022 12:10 PM I77700 APR 25, 2022 12:10 PM I77800 APR 25, 2022 12:10 PM I78C00 APR 25, 2022 12:10 PM I78300 APR 25, 2022 12:10 PM I78F00 APR 25, 2022 12:10 PM I78700 APR 25, 2022 12:10 PM I70200 APR 25, 2022 12:10 PM LIQUID LABEL DEVICE LABEL 1 UNL 1 STP 2 UNL 1 ANN 3 DSL STP 4 DSL ANN 5 6 PNL ANN 7 UNL 2 STP 8 UNL 2 ANN 9 DISP 1-2 10 DISP 3-4 11 DISP 5-6 12 DISP 7-8 13 TRANS SUMP NO 14 TRANS SUMP SO 15 PNL STP 16 UNL 1 ANN I70300 APR 25, 2022 12:10 PM LIQUID TYPE SENSOR LOCATION TYPE 1 UNL 1 STP TRI-STATE (SINGLE FLOAT) 2 UNL 1 ANN TRI-STATE (SINGLE FLOAT) 3 DSL STP TRI-STATE (SINGLE FLOAT) 4 DSL ANN TRI-STATE (SINGLE FLOAT) 5 TRI-STATE (SINGLE FLOAT) 6 PNL ANN TRI-STATE (SINGLE FLOAT) 7 UNL 2 STP TRI-STATE (SINGLE FLOAT) 8 UNL 2 ANN TRI-STATE (SINGLE FLOAT) 9 DISP 1-2 TRI-STATE (SINGLE FLOAT) 10 DISP 3-4 TRI-STATE (SINGLE FLOAT) 11 DISP 5-6 TRI-STATE (SINGLE FLOAT) 12 DISP 7-8 TRI-STATE (SINGLE FLOAT) 13 TRANS SUMP NO TRI-STATE (SINGLE FLOAT) 14 TRANS SUMP SO TRI-STATE (SINGLE FLOAT) 15 PNL STP TRI-STATE (SINGLE FLOAT) 16 UNL 1 ANN TRI-STATE (SINGLE FLOAT) I70400 APR 25, 2022 12:10 PM LIQUID CATEGORY SENSOR LOCATION CATEGORY 1 UNL 1 STP STP SUMP 2 UNL 1 ANN ANNULAR SPACE 3 DSL STP STP SUMP 4 DSL ANN ANNULAR SPACE 5 OTHER SENSORS 6 PNL ANN ANNULAR SPACE 7 UNL 2 STP STP SUMP 8 UNL 2 ANN ANNULAR SPACE 9 DISP 1-2 DISPENSER PAN 10 DISP 3-4 DISPENSER PAN 11 DISP 5-6 DISPENSER PAN 12 DISP 7-8 DISPENSER PAN 13 TRANS SUMP NO PIPING SUMP 14 TRANS SUMP SO PIPING SUMP 15 PNL STP STP SUMP 16 UNL 1 ANN ANNULAR SPACE I74200 APR 25, 2022 12:10 PM I74300 APR 25, 2022 12:10 PM I74400 APR 25, 2022 12:10 PM I74700 APR 25, 2022 12:10 PM I74800 APR 25, 2022 12:10 PM I74900 APR 25, 2022 12:10 PM I7BC00 APR 25, 2022 12:10 PM I80200 APR 25, 2022 12:10 PM I80300 APR 25, 2022 12:10 PM I80400 APR 25, 2022 12:10 PM I80700 APR 25, 2022 12:10 PM RELAY LABEL DEVICE LABEL 1 UNL 1 2 PNL 3 DSL 4 5 OVERFILL ALARM 6 7 8 I80900 APR 25, 2022 12:10 PM RELAY ORIENTATION RELAY DESIGNATION ORIENTATION 1 UNL 1 NORMALLY OPEN 2 PNL NORMALLY OPEN 3 DSL NORMALLY CLOSED 4 NORMALLY OPEN 5 OVERFILL ALARM NORMALLY OPEN 6 NORMALLY OPEN 7 NORMALLY OPEN 8 NORMALLY OPEN I80B00 APR 25, 2022 12:10 PM RELAY TANK ASSIGNMENT RELAY DESIGNATION TANK 1 UNL 1 1 2 PNL 3 3 DSL NONE 4 NONE 5 OVERFILL ALARM NONE 6 NONE 7 NONE 8 NONE I80A00 APR 25, 2022 12:11 PM RELAY TYPE RELAY DESIGNATION TYPE 1 UNL 1 PUMP CONTROL OUTPUT 2 PNL PUMP CONTROL OUTPUT 3 DSL STANDARD 4 STANDARD 5 OVERFILL ALARM STANDARD 6 STANDARD 7 STANDARD 8 STANDARD I80C00 APR 25, 2022 12:11 PM I80800 APR 25, 2022 12:11 PM RELAY SETUP REPORT R 1:UNL 1 TYPE: PUMP CONTROL OUTPUT TANK #: 1 LIQUID SENSOR ALMS L 1:FUEL ALARM L 7:FUEL ALARM L 9:FUEL ALARM L10:FUEL ALARM L11:FUEL ALARM L12:FUEL ALARM L 1:SENSOR OUT ALARM L 7:SENSOR OUT ALARM L 9:SENSOR OUT ALARM L10:SENSOR OUT ALARM L11:SENSOR OUT ALARM L12:SENSOR OUT ALARM L 1:SHORT ALARM L 7:SHORT ALARM L 9:SHORT ALARM L10:SHORT ALARM L11:SHORT ALARM L12:SHORT ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD VP PRES FAIL ISD VP STATUS FAIL ISD HOSE ALARMS ALL:GROSS COLLECT FAIL ALL:DEGRD COLLECT FAIL ALL:FLOW COLLECT FAIL R 2:PNL TYPE: PUMP CONTROL OUTPUT TANK #: 3 LIQUID SENSOR ALMS L 9:FUEL ALARM L10:FUEL ALARM L11:FUEL ALARM L12:FUEL ALARM L15:FUEL ALARM L 9:SENSOR OUT ALARM L10:SENSOR OUT ALARM L11:SENSOR OUT ALARM L12:SENSOR OUT ALARM L15:SENSOR OUT ALARM L 9:SHORT ALARM L10:SHORT ALARM L11:SHORT ALARM L12:SHORT ALARM L15:SHORT ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD VP PRES FAIL ISD VP STATUS FAIL ISD HOSE ALARMS ALL:GROSS COLLECT FAIL ALL:DEGRD COLLECT FAIL ALL:FLOW COLLECT FAIL R 3:DSL TYPE: STANDARD NORMALLY CLOSED TANK #: NONE LIQUID SENSOR ALMS L 3:FUEL ALARM L 9:FUEL ALARM L10:FUEL ALARM L11:FUEL ALARM L12:FUEL ALARM L13:FUEL ALARM L14:FUEL ALARM L 3:SENSOR OUT ALARM L 9:SENSOR OUT ALARM L10:SENSOR OUT ALARM L11:SENSOR OUT ALARM L12:SENSOR OUT ALARM L13:SENSOR OUT ALARM L14:SENSOR OUT ALARM L 3:SHORT ALARM L 9:SHORT ALARM L10:SHORT ALARM L11:SHORT ALARM L12:SHORT ALARM L13:SHORT ALARM L14:SHORT ALARM R 4: TYPE: STANDARD NORMALLY OPEN TANK #: NONE - NO ALARM ASSIGNMENTS - R 5:OVERFILL ALARM TYPE: STANDARD NORMALLY OPEN TANK #: NONE IN-TANK ALARMS ALL:OVERFILL ALARM ALL:HIGH PRODUCT ALARM ALL:MAX PRODUCT ALARM R 6: TYPE: STANDARD NORMALLY OPEN TANK #: NONE - NO ALARM ASSIGNMENTS - R 7: TYPE: STANDARD NORMALLY OPEN TANK #: NONE - NO ALARM ASSIGNMENTS - R 8: TYPE: STANDARD NORMALLY OPEN TANK #: NONE - NO ALARM ASSIGNMENTS - I79000 APR 25, 2022 12:11 PM EDIM:1 VR:349634-003-C TD:06.05.11.11.15 I79100 APR 25, 2022 12:11 PM I72300 APR 25, 2022 12:11 PM FASTRIP 347 2698 OSWELL ST BAKERSFIELD 93306 661-872-8721 SMARTSENSOR ASSIGNMENT DEVICE LABEL CATEGORY 01 PS 3-4 VAPOR PRESSURE 02 FM 1-2 AIR FLOW METER 03 FM 3-4 AIR FLOW METER 04 FM 5-6 AIR FLOW METER 05 FM 7-8 AIR FLOW METER 06 UNKNOWN 07 UNKNOWN 08 UNKNOWN 09 UNKNOWN 10 UNKNOWN 11 UNKNOWN 12 UNKNOWN 13 UNKNOWN 14 UNKNOWN 15 UNKNOWN 16 UNKNOWN 17 UNKNOWN 18 UNKNOWN 19 UNKNOWN 20 UNKNOWN 21 UNKNOWN 22 UNKNOWN 23 UNKNOWN 24 UNKNOWN 25 UNKNOWN 26 UNKNOWN 27 UNKNOWN 28 UNKNOWN 29 UNKNOWN 30 UNKNOWN 31 UNKNOWN 32 UNKNOWN 33 UNKNOWN 34 UNKNOWN 35 UNKNOWN 36 UNKNOWN 37 UNKNOWN 38 UNKNOWN 39 UNKNOWN 40 UNKNOWN IV4E00 APR 25, 2022 12:11 PM FASTRIP 347 2698 OSWELL ST BAKERSFIELD 93306 661-872-8721 EVR/ISD SETUP TYPE: VACUUM ASSIST VACUUM ASSIST TYPE: HEALY VAC IV4F00 APR 25, 2022 12:11 PM FASTRIP 347 2698 OSWELL ST BAKERSFIELD 93306 661-872-8721 NOZZLE A/L RANGE A/L RATIO: 0.95 - 1.15 IV4000 APR 25, 2022 12:11 PM FASTRIP 347 2698 OSWELL ST BAKERSFIELD 93306 661-872-8721 VAPOR PROCESSOR TYPE NONE IV4700 APR 25, 2022 12:11 PM FASTRIP 347 2698 OSWELL ST BAKERSFIELD 93306 661-872-8721 ASSESSMENT TIME START TIME: 10:00 AM TIME DELAY MINUTES: 1 IV5200 APR 25, 2022 12:11 PM FASTRIP 347 2698 OSWELL ST BAKERSFIELD 93306 661-872-8721 ACCEPT HIGH ORVR: YES IV4A00 APR 25, 2022 12:11 PM FASTRIP 347 2698 OSWELL ST BAKERSFIELD 93306 661-872-8721 ISD HOSE TABLE HOSE FP FP AFM HOSE ID ID LABEL ID LABEL 01 01 01 01 BLEND3 02 02 02 01 BLEND3 03 03 03 02 BLEND3 04 04 04 02 BLEND3 05 05 05 03 BLEND3 06 06 06 03 BLEND3 07 07 07 04 BLEND3 08 08 08 04 BLEND3 IV4B00 APR 25, 2022 12:11 PM FASTRIP 347 2698 OSWELL ST BAKERSFIELD 93306 661-872-8721 PRODUCT/HOSE MAP TABLE FP AFID M1/H1 M2/H2 M3/H3 M4/H4 01 01 02/01 03/01 09/01 xx/xx 02 01 02/02 03/02 09/02 xx/xx 03 02 02/03 03/03 09/03 xx/xx 04 02 02/04 03/04 09/04 xx/xx 05 03 02/05 03/05 09/05 xx/xx 06 03 02/06 03/06 09/06 xx/xx 07 04 02/07 03/07 09/07 xx/xx 08 04 02/08 03/08 09/08 xx/xx IV4900 APR 25, 2022 12:11 PM FASTRIP 347 2698 OSWELL ST BAKERSFIELD 93306 661-872-8721 LABEL TABLE ID LABEL 01 UNASSIGNED 02 BLEND3 03 REGULAR 04 MID GRADE 05 PREMIUM 06 GOLD 07 BRONZE 08 SILVER 09 BLEND2 10 BLEND4 IV1000 APR 25, 2022 12:11 PM ISD VERSION: 01.03 Alarm History Before. Responses Received: I10200 APR 25, 2022 12:12 PM FASTRIP 347 2698 OSWELL ST BAKERSFIELD 93306 661-872-8721 SYSTEM CONFIGURATION SLOT BOARD TYPE POWER ON RESET CURRENT 1 8SMARTSENSOR BD 39999 39606 2 4 PROBE / G.T. 164016 163093 3 INTERSTITIAL BD 202660 201723 4 INTERSTITIAL BD 201742 201016 5 UNUSED 4995371 4933017 6 UNUSED 4979090 4927866 7 UNUSED 4978325 4931230 8 UNUSED 4971404 4926583 9 STP SENSE BOARD 33199 33159 10 RELAY BOARD 14965 14965 11 RELAY BOARD 14945 14922 12 UNUSED 4975339 4935847 13 UNUSED 4970546 4928825 14 UNUSED 4971331 4926869 15 UNUSED 4970153 4927227 16 UNUSED 4969843 4931053 COMM 1 ELEC DISP INT. 100658 100563 COMM 2 RS232 SERIAL BD 14945 14922 COMM 3 RS232 SERIAL BD 15007 15007 COMM 4 UNUSED 4972447 4933744 COMM 5 UNUSED 4969347 4928047 COMM 6 UNUSED 4967653 4928635 I90200 APR 25, 2022 12:12 PM SOFTWARE REVISION LEVEL VERSION 330.01 SOFTWARE# 346330-100-B CREATED - 10.07.23.17.25 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD I11100 APR 25, 2022 12:12 PM FASTRIP 347 2698 OSWELL ST BAKERSFIELD 93306 661-872-8721 PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME T 4 TANK UNL 2 OVERFILL ALARM CLEAR 4-19-22 6:37PM T 4 TANK UNL 2 OVERFILL ALARM ALARM 4-19-22 6:26PM h 2 OTHER FP2: BLEND3 GROSS COLLECT FAIL CLEAR 4-19-22 5:09PM h 2 OTHER FP2: BLEND3 GROSS COLLECT FAIL ALARM 4-19-22 10:01AM f 1 OTHER FM 1-2 CHK VAPOR FLOW MTR CLEAR 4-19-22 10:00AM f 1 OTHER FM 1-2 CHK VAPOR FLOW MTR ALARM 4-17-22 10:01AM T 4 TANK UNL 2 OVERFILL ALARM CLEAR 4-16-22 2:21AM T 4 TANK UNL 2 OVERFILL ALARM ALARM 4-16-22 2:18AM T 4 TANK UNL 2 OVERFILL ALARM CLEAR 4-05-22 4:07AM T 4 TANK UNL 2 OVERFILL ALARM ALARM 4-05-22 4:02AM f 1 OTHER FM 1-2 CHK VAPOR FLOW MTR CLEAR 3-27-22 10:00AM f 1 OTHER FM 1-2 CHK VAPOR FLOW MTR ALARM 3-26-22 10:01AM T 4 TANK UNL 2 OVERFILL ALARM CLEAR 3-17-22 2:37AM T 4 TANK UNL 2 OVERFILL ALARM ALARM 3-17-22 2:33AM s 4 OTHER FM 5-6 COMMUNICATION ALARM CLEAR 3-16-22 5:29PM s 4 OTHER FM 5-6 COMMUNICATION ALARM ALARM 3-16-22 5:27PM T 4 TANK UNL 2 OVERFILL ALARM CLEAR 3-14-22 2:26AM T 4 TANK UNL 2 OVERFILL ALARM ALARM 3-14-22 2:20AM T 4 TANK UNL 2 OVERFILL ALARM CLEAR 12-30-21 12:56AM T 4 TANK UNL 2 OVERFILL ALARM ALARM 12-30-21 12:50AM T 1 TANK UNL 1 OVERFILL ALARM CLEAR 12-25-21 8:21PM T 4 TANK UNL 2 OVERFILL ALARM CLEAR 12-25-21 8:21PM T 1 TANK UNL 1 OVERFILL ALARM ALARM 12-25-21 8:15PM T 4 TANK UNL 2 OVERFILL ALARM ALARM 12-25-21 8:09PM L 8 ANNULAR UNL 2 ANN SENSOR OUT ALARM CLEAR 12-02-21 8:17AM L 8 ANNULAR UNL 2 ANN SENSOR OUT ALARM ALARM 12-02-21 8:12AM L 8 ANNULAR UNL 2 ANN FUEL ALARM CLEAR 12-02-21 8:10AM L 8 ANNULAR UNL 2 ANN FUEL ALARM ALARM 12-02-21 8:01AM L 8 ANNULAR UNL 2 ANN SENSOR OUT ALARM CLEAR 12-02-21 7:59AM L 8 ANNULAR UNL 2 ANN SENSOR OUT ALARM ALARM 12-02-21 7:50AM L 8 ANNULAR UNL 2 ANN FUEL ALARM CLEAR 12-02-21 7:50AM L16 ANNULAR UNL 1 ANN SENSOR OUT ALARM CLEAR 12-01-21 2:18PM L 8 ANNULAR UNL 2 ANN SENSOR OUT ALARM CLEAR 12-01-21 2:17PM L 8 ANNULAR UNL 2 ANN FUEL ALARM ALARM 12-01-21 2:17PM L16 ANNULAR UNL 1 ANN SENSOR OUT ALARM ALARM 12-01-21 2:16PM L16 ANNULAR UNL 1 ANN FUEL ALARM CLEAR 12-01-21 2:16PM L16 ANNULAR UNL 1 ANN FUEL ALARM ALARM 12-01-21 2:13PM L 8 ANNULAR UNL 2 ANN SENSOR OUT ALARM ALARM 12-01-21 2:12PM L 8 ANNULAR UNL 2 ANN FUEL ALARM CLEAR 12-01-21 2:12PM L 8 ANNULAR UNL 2 ANN SENSOR OUT ALARM CLEAR 12-01-21 2:06PM L 8 ANNULAR UNL 2 ANN FUEL ALARM ALARM 12-01-21 2:06PM L 8 ANNULAR UNL 2 ANN SENSOR OUT ALARM ALARM 12-01-21 1:56PM L 8 ANNULAR UNL 2 ANN FUEL ALARM CLEAR 12-01-21 1:56PM L 8 ANNULAR UNL 2 ANN FUEL ALARM ALARM 12-01-21 1:03PM L 8 ANNULAR UNL 2 ANN SENSOR OUT ALARM CLEAR 12-01-21 1:03PM L 8 ANNULAR UNL 2 ANN SENSOR OUT ALARM ALARM 12-01-21 12:56PM L 8 ANNULAR UNL 2 ANN FUEL ALARM CLEAR 12-01-21 12:56PM L 8 ANNULAR UNL 2 ANN FUEL ALARM ALARM 12-01-21 12:55PM L 8 ANNULAR UNL 2 ANN FUEL ALARM CLEAR 12-01-21 12:55PM L 2 ANNULAR UNL 1 ANN FUEL ALARM CLEAR 12-01-21 12:48PM I11200 APR 25, 2022 12:12 PM FASTRIP 347 2698 OSWELL ST BAKERSFIELD 93306 661-872-8721 NON-PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME h 1 OTHER FP1: BLEND3 DEGRD COLLECT WARN CLEAR 4-24-22 10:00AM h 1 OTHER FP1: BLEND3 DEGRD COLLECT WARN ALARM 4-23-22 10:01AM h 2 OTHER FP2: BLEND3 DEGRD COLLECT WARN CLEAR 4-19-22 5:09PM OTHER ISD SENSOR OUT WARN CLEAR 4-19-22 10:01AM h 2 OTHER FP2: BLEND3 DEGRD COLLECT WARN ALARM 4-19-22 10:01AM h 2 OTHER FP2: BLEND3 GROSS COLLECT WARN CLEAR 4-19-22 10:00AM h 2 OTHER FP2: BLEND3 GROSS COLLECT WARN ALARM 4-18-22 10:01AM h 4 OTHER FP4: BLEND3 DEGRD COLLECT WARN CLEAR 4-18-22 10:00AM OTHER ISD SENSOR OUT WARN ALARM 4-17-22 10:01AM h 4 OTHER FP4: BLEND3 DEGRD COLLECT WARN ALARM 4-16-22 10:01AM OTHER ISD VAPOR LEAK WARN CLEAR 4-05-22 10:00AM OTHER ISD VAPOR LEAK WARN ALARM 4-03-22 10:01AM OTHER ISD VAPOR LEAK WARN CLEAR 4-02-22 10:00AM OTHER ISD VAPOR LEAK WARN ALARM 3-31-22 10:01AM h 6 OTHER FP6: BLEND3 DEGRD COLLECT WARN CLEAR 3-29-22 11:14AM h 4 OTHER FP4: BLEND3 DEGRD COLLECT WARN CLEAR 3-29-22 11:14AM h 2 OTHER FP2: BLEND3 DEGRD COLLECT WARN CLEAR 3-29-22 10:00AM h 6 OTHER FP6: BLEND3 DEGRD COLLECT WARN ALARM 3-28-22 10:01AM OTHER ISD SENSOR OUT WARN CLEAR 3-27-22 10:01AM OTHER ISD SENSOR OUT WARN ALARM 3-26-22 10:01AM h 4 OTHER FP4: BLEND3 DEGRD COLLECT WARN ALARM 3-26-22 10:01AM h 2 OTHER FP2: BLEND3 DEGRD COLLECT WARN ALARM 3-26-22 10:01AM h 2 OTHER FP2: BLEND3 DEGRD COLLECT WARN CLEAR 3-22-22 9:27AM SYSTEM PRINTER ERROR CLEAR 3-18-22 7:22AM SYSTEM PAPER OUT CLEAR 3-18-22 7:21AM SYSTEM PRINTER ERROR ALARM 3-18-22 7:21AM SYSTEM PAPER OUT ALARM 3-18-22 7:21AM h 2 OTHER FP2: BLEND3 DEGRD COLLECT WARN ALARM 3-14-22 10:01AM OTHER ISD GROSS PRES WARN CLEAR 2-08-22 1:59PM OTHER ISD GROSS PRES WARN ALARM 2-08-22 10:02AM OTHER ISD GROSS PRES WARN CLEAR 2-01-22 4:53PM OTHER ISD GROSS PRES WARN ALARM 1-31-22 10:02AM SYSTEM PRINTER ERROR CLEAR 1-02-22 11:33AM SYSTEM PAPER OUT CLEAR 1-02-22 11:33AM SYSTEM PAPER OUT ALARM 1-02-22 11:33AM SYSTEM PAPER OUT CLEAR 1-02-22 11:33AM SYSTEM PAPER OUT ALARM 1-02-22 11:33AM SYSTEM PAPER OUT CLEAR 1-02-22 11:33AM SYSTEM PAPER OUT ALARM 1-02-22 11:33AM SYSTEM PRINTER ERROR ALARM 1-02-22 11:33AM SYSTEM PAPER OUT CLEAR 1-02-22 11:33AM SYSTEM PAPER OUT ALARM 1-02-22 11:32AM SYSTEM PRINTER ERROR CLEAR 12-27-21 4:56PM SYSTEM PRINTER ERROR ALARM 12-27-21 4:56PM L16 ANNULAR UNL 1 ANN SETUP DATA WARNING CLEAR 12-01-21 2:13PM L16 ANNULAR UNL 1 ANN SETUP DATA WARNING ALARM 12-01-21 2:12PM SYSTEM PAPER OUT CLEAR 11-25-21 9:58AM SYSTEM PAPER OUT ALARM 11-25-21 9:58AM SYSTEM PRINTER ERROR CLEAR 11-08-21 7:13AM SYSTEM PRINTER ERROR ALARM 11-08-21 7:13AM I20600 APR 25, 2022 12:12 PM FASTRIP 347 2698 OSWELL ST BAKERSFIELD 93306 661-872-8721 TANK ALARM HISTORY TANK 1 UNL 1 SETUP DATA WARNING JUL 30, 2014 9:29 AM OVERFILL ALARM DEC 25, 2021 8:15 PM NOV 5, 2021 12:10 AM OCT 17, 2021 9:19 PM LOW PRODUCT ALARM AUG 17, 2018 11:12 PM AUG 16, 2018 6:33 PM AUG 13, 2018 4:09 PM SUDDEN LOSS ALARM AUG 2, 2018 9:07 AM JUL 26, 2018 9:56 AM AUG 3, 2017 9:15 AM HIGH PRODUCT ALARM JUL 28, 2017 10:25 AM AUG 10, 2015 10:06 AM AUG 5, 2014 10:12 AM INVALID FUEL LEVEL AUG 18, 2018 7:34 AM AUG 17, 2018 2:04 AM AUG 10, 2015 10:04 AM PROBE OUT NOV 9, 2021 9:39 AM AUG 27, 2020 12:24 PM AUG 27, 2020 12:19 PM DELIVERY NEEDED AUG 17, 2018 11:12 PM AUG 16, 2018 6:33 PM AUG 13, 2018 4:09 PM LOW TEMP WARNING AUG 27, 2020 12:26 PM AUG 2, 2018 9:42 AM JUL 26, 2018 10:07 AM TANK 2 DIESEL SETUP DATA WARNING JUL 30, 2014 9:30 AM OVERFILL ALARM AUG 27, 2020 12:32 PM JUL 26, 2018 10:07 AM AUG 3, 2017 9:43 AM LOW PRODUCT ALARM APR 1, 2021 11:05 PM JUL 27, 2016 8:49 AM FEB 22, 2016 11:02 AM HIGH PRODUCT ALARM AUG 2, 2018 9:42 AM JUL 26, 2018 10:07 AM AUG 3, 2017 9:43 AM INVALID FUEL LEVEL APR 1, 2021 11:09 PM JUL 26, 2018 10:08 AM AUG 4, 2016 8:40 AM PROBE OUT AUG 27, 2020 12:32 PM AUG 27, 2020 12:27 PM AUG 2, 2018 9:42 AM HIGH WATER WARNING JUL 26, 2018 10:06 AM DELIVERY NEEDED APR 1, 2021 11:05 PM JUL 27, 2016 8:49 AM FEB 22, 2016 11:01 AM LOW TEMP WARNING AUG 27, 2020 12:44 PM AUG 3, 2017 10:18 AM AUG 5, 2015 10:10 AM TANK 3 PNL SETUP DATA WARNING JUL 30, 2014 9:31 AM OVERFILL ALARM AUG 27, 2020 12:35 PM SEP 4, 2018 1:48 AM JUL 26, 2018 10:09 AM LOW PRODUCT ALARM APR 27, 2016 7:12 PM FEB 20, 2016 5:19 PM AUG 30, 2013 4:50 AM SUDDEN LOSS ALARM JUL 5, 2019 8:14 PM AUG 2, 2018 9:05 AM JUL 26, 2018 9:58 AM HIGH PRODUCT ALARM AUG 2, 2018 9:44 AM JUL 28, 2017 10:27 AM AUG 10, 2015 10:23 AM INVALID FUEL LEVEL FEB 21, 2016 4:15 PM AUG 5, 2015 10:13 AM AUG 11, 2011 9:26 AM PROBE OUT AUG 27, 2020 12:36 PM AUG 27, 2020 12:34 PM DEC 11, 2018 11:42 AM DELIVERY NEEDED APR 27, 2016 7:03 PM FEB 20, 2016 5:19 PM AUG 30, 2013 4:49 AM LOW TEMP WARNING AUG 3, 2017 10:17 AM AUG 10, 2015 10:14 AM AUG 5, 2014 10:20 AM TANK 4 UNL 2 SETUP DATA WARNING JUL 30, 2014 9:32 AM OVERFILL ALARM APR 19, 2022 6:26 PM APR 16, 2022 2:18 AM APR 5, 2022 4:02 AM LOW PRODUCT ALARM JUL 28, 2017 10:00 AM JUL 27, 2016 8:47 AM AUG 10, 2015 10:08 AM SUDDEN LOSS ALARM AUG 2, 2018 9:07 AM JUL 26, 2018 9:56 AM AUG 3, 2017 9:15 AM HIGH PRODUCT ALARM AUG 2, 2018 9:40 AM JUL 28, 2017 10:22 AM OCT 15, 2016 5:24 AM INVALID FUEL LEVEL JUL 27, 2016 8:47 AM JUL 31, 2013 10:09 AM JUL 31, 2013 9:18 AM PROBE OUT AUG 27, 2020 12:17 PM AUG 27, 2020 12:15 PM JUL 5, 2019 8:16 PM DELIVERY NEEDED JUL 28, 2017 10:00 AM JUL 27, 2016 8:47 AM AUG 10, 2015 10:08 AM LOW TEMP WARNING JUL 5, 2019 8:17 PM JUL 26, 2018 10:05 AM JUL 28, 2017 10:23 AM I38200 APR 25, 2022 12:12 PM I30200 APR 25, 2022 12:12 PM FASTRIP 347 2698 OSWELL ST BAKERSFIELD 93306 661-872-8721 LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 UNL 1 STP NOV 4, 2021 4:11 PM SENSOR OUT ALARM NOV 4, 2021 4:11 PM FUEL ALARM NOV 4, 2021 4:09 PM SENSOR OUT ALARM 2 UNL 1 ANN DEC 1, 2021 12:48 PM FUEL ALARM DEC 1, 2021 12:38 PM FUEL ALARM NOV 30, 2021 11:45 AM SENSOR OUT ALARM 3 DSL STP NOV 4, 2021 4:12 PM SENSOR OUT ALARM NOV 4, 2021 4:11 PM FUEL ALARM NOV 4, 2021 4:11 PM SENSOR OUT ALARM 4 DSL ANN NOV 4, 2021 4:09 PM SENSOR OUT ALARM AUG 18, 2021 9:27 AM SENSOR OUT ALARM AUG 18, 2021 9:15 AM FUEL ALARM 6 PNL ANN NOV 28, 2021 5:22 PM SENSOR OUT ALARM NOV 4, 2021 4:10 PM SENSOR OUT ALARM NOV 4, 2021 11:27 AM SENSOR OUT ALARM 7 UNL 2 STP NOV 4, 2021 4:14 PM FUEL ALARM NOV 4, 2021 4:09 PM SENSOR OUT ALARM AUG 18, 2021 9:27 AM SENSOR OUT ALARM 8 UNL 2 ANN DEC 2, 2021 8:12 AM SENSOR OUT ALARM DEC 2, 2021 8:01 AM FUEL ALARM DEC 2, 2021 7:50 AM SENSOR OUT ALARM 9 DISP 1-2 NOV 4, 2021 4:10 PM SENSOR OUT ALARM NOV 4, 2021 4:10 PM FUEL ALARM NOV 4, 2021 4:09 PM SENSOR OUT ALARM 10 DISP 3-4 NOV 4, 2021 4:09 PM SENSOR OUT ALARM AUG 18, 2021 9:27 AM SENSOR OUT ALARM AUG 18, 2021 9:17 AM FUEL ALARM 11 DISP 5-6 NOV 4, 2021 4:09 PM SENSOR OUT ALARM AUG 18, 2021 9:28 AM SENSOR OUT ALARM AUG 18, 2021 9:18 AM FUEL ALARM 12 DISP 7-8 NOV 4, 2021 4:09 PM SENSOR OUT ALARM AUG 18, 2021 9:28 AM SENSOR OUT ALARM AUG 18, 2021 9:20 AM FUEL ALARM 13 TRANS SUMP NO NOV 4, 2021 4:09 PM SENSOR OUT ALARM AUG 18, 2021 9:28 AM SENSOR OUT ALARM AUG 18, 2021 9:19 AM FUEL ALARM 14 TRANS SUMP SO NOV 4, 2021 4:09 PM SENSOR OUT ALARM AUG 18, 2021 9:28 AM SENSOR OUT ALARM AUG 18, 2021 9:17 AM FUEL ALARM 15 PNL STP NOV 23, 2021 8:21 PM FUEL ALARM NOV 19, 2021 9:42 AM FUEL ALARM NOV 16, 2021 3:38 PM FUEL ALARM I31600 APR 25, 2022 12:12 PM FASTRIP 347 2698 OSWELL ST BAKERSFIELD 93306 661-872-8721 SMART SENSOR ALARM HISTORY REPORT SENSOR LOCATION 1 PS 3-4 2 FM 1-2 3 FM 3-4 4 FM 5-6 MAR 16, 2022 5:27 PM COMMUNICATION ALARM 5 FM 7-8 I40200 APR 25, 2022 12:12 PM I40300 APR 25, 2022 12:12 PM I34200 APR 25, 2022 12:12 PM I34700 APR 25, 2022 12:12 PM IV0100 APR 25, 2022 12:12 PM FASTRIP 347 2698 OSWELL ST BAKERSFIELD 93306 661-872-8721 ISD ALARM STATUS REPORT EVR TYPE: VACUUM ASSIST ISD TYPE: 01.03 VAPOR PROCESSOR TYPE: NONE OVERALL STATUS :PASS EVR VAPOR COLLECTION :PASS EVR VAPOR CONTAINMENT :PASS ISD MONITOR UP-TIME :100% EVR/ISD PASS TIME :100% WARNING ALARMS DATE TIME DESCRIPTION READING VALUE 22-04-23 10:01:09 A/L RATIO DEGRADATION FP 1 BLEND3 0.80 22-04-19 10:01:09 A/L RATIO DEGRADATION FP 2 BLEND3 BLKD 22-04-18 10:01:09 SENSOR OUT SELFTEST CHECK VAPOR FLOW METER f 1:FM 1-2 22-04-18 10:01:09 A/L RATIO GROSS BLOCKAGE FP 2 BLEND3 BLKD 22-04-17 10:01:09 SENSOR OUT SELFTEST CHECK VAPOR FLOW METER f 1:FM 1-2 22-04-17 10:01:09 A/L RATIO DEGRADATION FP 4 BLEND3 0.78 22-04-16 10:01:09 A/L RATIO DEGRADATION FP 4 BLEND3 0.79 22-04-03 10:01:09 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 16.62 22-03-31 10:01:09 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 8.85 22-03-29 10:01:09 A/L RATIO DEGRADATION FP 6 BLEND3 0.76 FAILURE ALARMS DATE TIME DESCRIPTION READING VALUE 22-04-19 10:01:09 A/L RATIO GROSS BLOCKAGE FP 2 BLEND3 BLKD 15-12-16 10:01:58 A/L RATIO GROSS BLOCKAGE FP 8 BLEND3 BLKD 15-12-16 10:01:58 A/L RATIO GROSS BLOCKAGE FP 7 BLEND3 BLKD 15-12-15 10:01:56 A/L RATIO GROSS BLOCKAGE FP 8 BLEND3 BLKD 12-08-18 10:02:49 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 2.70 11-08-25 10:02:34 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 2.05 SHUTDOWN & MISCELLANEOUS EVENTS DATE TIME DESCRIPTION ACTION/NAME 22-04-19 17:09:19 COLLECTION TEST HH02 GRADE TEST MANUALLY CLEARED 22-04-19 11:18:05 PUMPS MANUALLY RE-ENABLED 22-04-19 10:01:09 A/L RATIO GROSS BLOCKAGE DISABLED FP 02 BLEND3 22-03-29 11:14:36 COLLECTION TEST HH06 GRADE TEST MANUALLY CLEARED 22-03-29 11:14:27 COLLECTION TEST HH06 GRADE TEST MANUALLY CLEARED 22-03-29 11:14:22 COLLECTION TEST HH04 GRADE TEST MANUALLY CLEARED 22-03-25 10:01:09 READINESS ISD:PP EVR:PP ISD & EVR READY 22-03-24 11:30:59 READINESS ISD:PP EVR:NN EVR READINESS PENDING 22-03-24 11:30:59 ISD STARTUP 22-03-24 11:29:42 ISD SHUTDOWN ISD Setup. IV4200 APR 25, 2022 12:14 PM Sensor / Airflow Meter / Hose Table / Grade Table Relationship SS AA F1 FL M1H1L1 M2H2L2 M3H3L3 M4H4L4 F2 L2 M1H1L1 M2H2L2 M3H3L3 M4H4L4 02 01 02 01 030102 040102 100102 060000 03 02 030202 040202 100202 060000 03 02 04 03 030302 040302 100302 000000 05 04 030402 040402 100402 000000 04 03 06 05 030502 040502 100502 060000 07 06 030602 040602 100602 060000 05 04 08 07 030702 040702 100702 000000 09 08 030802 040802 100802 000000 > Jaco 3347 Setup, Alarm History After. Setup. Responses Received: 200 FASTRIP 347 2698 OSWELL ST BAKERSFIELD 93306 661-872-8721 APR 25, 2022 1:27 PM TANK PRODUCT GALLONS INCHES WATER DEG F ULLAGE 1 UNL 1 8765 65.79 0.0 64.9 3235 2 DIESEL 3902 34.64 0.8 69.8 8098 3 PNL 7153 55.27 0.0 68.4 4847 4 UNL 2 9020 67.53 0.7 64.1 2980 I90500 APR 25, 2022 1:27 PM SOFTWARE REVISION LEVEL VERSION 336.02 SOFTWARE# 346336-100-C CREATED - 21.02.13.11.53 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD/APM I50500 APR 25, 2022 1:27 PM SYSTEM TYPE AND LANGUAGE FLAG SYSTEM UNITS U.S. SYSTEM LANGUAGE ENGLISH SYSTEM DATE/TIME FORMAT MON DD YYYY HH:MM:SS xM I50201 APR 25, 2022 1:27 PM SHIFT TIME 1 : 6:00 AM I50202 APR 25, 2022 1:27 PM SHIFT TIME 2 : DISABLED I50203 APR 25, 2022 1:27 PM SHIFT TIME 3 : DISABLED I50204 APR 25, 2022 1:27 PM SHIFT TIME 4 : DISABLED I54600 APR 25, 2022 1:28 PM TANK PER TST NEEDED WRN: DISABLED I54900 APR 25, 2022 1:28 PM TANK ANN TST NEEDED WRN: DISABLED I55300 APR 25, 2022 1:28 PM LINE RE-ENABLE METHOD PASS LINE TEST I55600 APR 25, 2022 1:28 PM LINE PER TST NEEDED WRN: DISABLED I55900 APR 25, 2022 1:28 PM LINE ANN TST NEEDED WRN: DISABLED I50D00 APR 25, 2022 1:28 PM PRINT TC VOLUMES ENABLED I50E00 APR 25, 2022 1:28 PM TEMP COMPENSATION VALUE (DEG F ): 60.0 I60B00 APR 25, 2022 1:28 PM STICK HEIGHT OFFSET ENABLE STATUS DISABLED I51400 APR 25, 2022 1:28 PM H-PROTOCOL DATA FORMAT HEIGHT I51A01 APR 25, 2022 1:28 PM DAYLIGHT SAVING TIME ENABLED ON I51B00 APR 25, 2022 1:28 PM DAYLIGHT SAVING TIME START DATE MAR WEEK 2 SUN 2:00 AM END DATE NOV WEEK 1 SUN 2:00 AM I51600 APR 25, 2022 1:28 PM RE-DIRECT LOCAL PRINTOUT DISABLED I50400 APR 25, 2022 1:28 PM 232 SECURITY CODE PORT SECURITY CODE STATUS 1 000000 DISABLED 2 000000 DISABLED 3 000000 DISABLED 4 000000 DISABLED 5 000000 DISABLED 6 000000 DISABLED I21900 APR 25, 2022 1:28 PM TANK CHART SECURITY DISABLED I5BD00 APR 25, 2022 1:28 PM CUSTOM ALARM LABELS DISABLED I56000 APR 25, 2022 1:28 PM MASS/DENSITY DISABLED I88101 APR 25, 2022 1:28 PM PORT SETTINGS: COMM BOARD : 1 (EDIM ) RS-232 SECURITY CODE : DISABLED I88102 APR 25, 2022 1:28 PM PORT SETTINGS: COMM BOARD : 2 (RS-232) BAUD RATE : 9600 PARITY : NONE STOP BIT : 1 STOP DATA LENGTH: 8 DATA RS-232 SECURITY CODE : DISABLED I88103 APR 25, 2022 1:28 PM PORT SETTINGS: COMM BOARD : 3 (RS-232) BAUD RATE : 9600 PARITY : NONE STOP BIT : 1 STOP DATA LENGTH: 8 DATA RS-232 SECURITY CODE : DISABLED I88104 APR 25, 2022 1:28 PM I88105 APR 25, 2022 1:28 PM I88106 APR 25, 2022 1:28 PM I52000 APR 25, 2022 1:28 PM RECEIVER AUTO DIAL TYPE & START TIME RCVR LOCATION LABEL DIAL TYPE START TIME 1 ON DATE ??? 25, 2022 DISABLED 2 ON DATE ??? 25, 2022 DISABLED 3 ON DATE ??? 25, 2022 DISABLED 4 ON DATE ??? 25, 2022 DISABLED 5 ON DATE ??? 25, 2022 DISABLED 6 ON DATE ??? 25, 2022 DISABLED 7 ON DATE ??? 25, 2022 DISABLED 8 ON DATE ??? 25, 2022 DISABLED I60100 APR 25, 2022 1:28 PM TANK CONFIGURATION DEVICE LABEL CONFIGURED 1 UNL 1 ON 2 DIESEL ON 3 PNL ON 4 UNL 2 ON I60200 APR 25, 2022 1:28 PM TANK PRODUCT LABEL TANK PRODUCT LABEL 1 UNL 1 2 DIESEL 3 PNL 4 UNL 2 I60300 APR 25, 2022 1:28 PM TANK PRODUCT CODE TANK PRODUCT LABEL 1 UNL 1 1 2 DIESEL 2 3 PNL 3 4 UNL 2 4 I60900 APR 25, 2022 1:28 PM TANK THERMAL COEFFICIENT TANK PRODUCT LABEL 1 UNL 1 0.000700 2 DIESEL 0.000450 3 PNL 0.000700 4 UNL 2 0.000700 I60700 APR 25, 2022 1:28 PM TANK DIAMETER TANK PRODUCT LABEL INCHES 1 UNL 1 96.00 2 DIESEL 96.00 3 PNL 96.00 4 UNL 2 96.00 I60A00 APR 25, 2022 1:28 PM TANK FULL VOLUME TANK PRODUCT LABEL TANK PROFILE GALLONS 1 UNL 1 1 PT 12000 2 DIESEL 1 PT 12000 3 PNL 1 PT 12000 4 UNL 2 1 PT 12000 I60400 APR 25, 2022 1:28 PM TANK FULL VOLUME TANK PRODUCT LABEL GALLONS 1 UNL 1 12000 2 DIESEL 12000 3 PNL 12000 4 UNL 2 12000 I60500 APR 25, 2022 1:28 PM TANK 4 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 UNL 1 12000 0 0 0 2 DIESEL 12000 0 0 0 3 PNL 12000 0 0 0 4 UNL 2 12000 0 0 0 I60600 APR 25, 2022 1:28 PM TANK 20 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 UNL 1 12000 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 DIESEL 12000 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3 PNL 12000 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4 UNL 2 12000 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 I61500 APR 25, 2022 1:28 PM TANK PRODUCT LABEL METER DATA 1 UNL 1 NO 2 DIESEL NO 3 PNL NO 4 UNL 2 NO I62F00 APR 25, 2022 1:28 PM MAG PROBE FLOAT SIZE TANK PRODUCT LABEL FLOAT SIZE: 1 UNL 1 4.0 IN. 2 DIESEL 4.0 IN. 3 PNL 4.0 IN. 4 UNL 2 3.0 IN. I62700 APR 25, 2022 1:28 PM TANK HIGH WATER WARNING LIMIT TANK PRODUCT LABEL INCHES 1 UNL 1 2.0 2 DIESEL 2.0 3 PNL 2.0 4 UNL 2 2.0 I64200 APR 25, 2022 1:28 PM WATER ALARM FILTER TANK PRODUCT LABEL 1 UNL 1 LOW 2 DIESEL LOW 3 PNL LOW 4 UNL 2 LOW I62400 APR 25, 2022 1:28 PM TANK HIGH WATER LEVEL LIMIT TANK PRODUCT LABEL INCHES 1 UNL 1 3.0 2 DIESEL 3.0 3 PNL 3.0 4 UNL 2 3.0 I62800 APR 25, 2022 1:28 PM TANK MAXIMUM VOLUME LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 1 12000 2 DIESEL 12000 3 PNL 12000 4 UNL 2 12000 I62300 APR 25, 2022 1:28 PM TANK OVERFILL LEVEL LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 1 10800 2 DIESEL 10800 3 PNL 10800 4 UNL 2 10800 I62200 APR 25, 2022 1:28 PM TANK HIGH PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 1 11400 2 DIESEL 11400 3 PNL 11400 4 UNL 2 11400 I62900 APR 25, 2022 1:28 PM TANK DELIVERY REQUIRED LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 1 1200 2 DIESEL 1200 3 PNL 1200 4 UNL 2 1200 I62100 APR 25, 2022 1:28 PM TANK LOW PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 1 1200 2 DIESEL 1200 3 PNL 1200 4 UNL 2 1200 I62600 APR 25, 2022 1:28 PM TANK LEAK ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 1 99 2 DIESEL 99 3 PNL 99 4 UNL 2 99 I62500 APR 25, 2022 1:28 PM TANK SUDDEN LOSS LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 1 99 2 DIESEL 99 3 PNL 99 4 UNL 2 99 I60800 APR 25, 2022 1:28 PM TANK TILT TANK PRODUCT LABEL INCHES 1 UNL 1 0.00 2 DIESEL 0.00 3 PNL 0.00 4 UNL 2 0.00 I60B00 APR 25, 2022 1:28 PM STICK HEIGHT OFFSET ENABLE STATUS DISABLED I60C00 APR 25, 2022 1:28 PM TANK STICK HEIGHT OFFSET TANK PRODUCT LABEL INCHES 1 UNL 1 0.00 2 DIESEL 0.00 3 PNL 0.00 4 UNL 2 0.00 I61200 APR 25, 2022 1:28 PM TANK MANIFOLDED PARTNERS TANK PRODUCT LABEL SIPHON MANIFOLDED TANKS LINE MANIFOLDED TANKS 1 UNL 1 4 NONE 2 DIESEL NONE NONE 3 PNL NONE NONE 4 UNL 2 1 NONE I63600 APR 25, 2022 1:28 PM PERIODIC LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 UNL 1 120 2 DIESEL 120 3 PNL 120 4 UNL 2 120 I62A00 APR 25, 2022 1:28 PM ANNUAL LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 UNL 1 0 2 DIESEL 0 3 PNL 0 4 UNL 2 0 I62C00 APR 25, 2022 1:28 PM TANK PERIODIC TEST TYPE TANK PRODUCT LABEL PERIODIC TEST TYPE 1 UNL 1 STANDARD 2 DIESEL STANDARD 3 PNL STANDARD 4 UNL 2 STANDARD I62D00 APR 25, 2022 1:28 PM TANK LEAK TEST FAIL ALARMS TANK PRODUCT LABEL 1 UNL 1 GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED 2 DIESEL GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED 3 PNL GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED 4 UNL 2 GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED I63100 APR 25, 2022 1:28 PM TANK LEAK TEST AVERAGING TANK PRODUCT LABEL ANNUAL PERIODIC 1 UNL 1 OFF OFF 2 DIESEL OFF OFF 3 PNL OFF OFF 4 UNL 2 OFF OFF I63000 APR 25, 2022 1:28 PM IN-TANK LEAK TEST NOTIFY TANK PRODUCT LABEL TANK TEST NOTIFY: 1 UNL 1 OFF 2 DIESEL OFF 3 PNL OFF 4 UNL 2 OFF I63200 APR 25, 2022 1:28 PM TANK TEST SIPHON BREAK TANK PRODUCT LABEL SIPHON BREAK 1 UNL 1 OFF 2 DIESEL OFF 3 PNL OFF 4 UNL 2 OFF I61000 APR 25, 2022 1:28 PM TANK DELIVERY DELAY TANK PRODUCT LABEL 1 UNL 1 1 2 DIESEL 1 3 PNL 1 4 UNL 2 1 I63A00 APR 25, 2022 1:28 PM LOW LEVEL PUMP THRESHOLD FOR SEQUENTIAL LINE MANIFOLD TANK PRODUCT LABEL PUMP THRESHOLD 1 UNL 1 10.00% 2 DIESEL 10.00% 3 PNL 10.00% 4 UNL 2 10.00% I61100 APR 25, 2022 1:28 PM LEAK TEST METHOD - - - - - - - - - - - - TEST ON DATE : ALL TANK JUL 23, 2010 START TIME : DISABLED TEST RATE :0.20 GAL/HR DURATION : 2 HOURS TST EARLY STOP:DISABLED I61300 APR 25, 2022 1:28 PM CSLD PROBABLITY OF DETECTION I61400 APR 25, 2022 1:28 PM CSLD CLIMATE FACTOR I61600 APR 25, 2022 1:28 PM TANK PRODUCT LABEL CAL UPDATE 1 UNL 1 IMMEDIATE 2 DIESEL IMMEDIATE 3 PNL IMMEDIATE 4 UNL 2 IMMEDIATE I61A00 APR 25, 2022 1:28 PM IN-TANK LEAK TEST EARLY STOP TANK PRODUCT LABEL TST EARLY STOP: 1 UNL 1 DISABLED 2 DIESEL DISABLED 3 PNL DISABLED 4 UNL 2 DISABLED I61B00 APR 25, 2022 1:28 PM IN-TANK LEAK GROSS TEST AUTO-CONFIRM I61C00 APR 25, 2022 1:28 PM CSLD REPORT ONLY I62B00 APR 25, 2022 1:28 PM TANK LAST ANNUAL TEST TANK PRODUCT LABEL DATE 1 UNL 1 ??? 0, 0 2 DIESEL ??? 0, 0 3 PNL ??? 0, 0 4 UNL 2 ??? 0, 0 I63300 APR 25, 2022 1:28 PM LEAK TEST REPORT FORMAT: NORMAL I63400 APR 25, 2022 1:28 PM RECONCILIATION WARNING LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 1 0 2 DIESEL 0 3 PNL 0 4 UNL 2 0 I63500 APR 25, 2022 1:28 PM RECONCILIATION ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 UNL 1 1 2 DIESEL 1 3 PNL 1 4 UNL 2 1 I63900 APR 25, 2022 1:28 PM ACCU CHART END SHAPE FACTOR TANK PRODUCT LABEL 1 UNL 1 END FACTOR: NONE 2 DIESEL END FACTOR: NONE 3 PNL END FACTOR: NONE 4 UNL 2 END FACTOR: NONE I78000 APR 25, 2022 1:28 PM I77700 APR 25, 2022 1:28 PM I77800 APR 25, 2022 1:28 PM I78C00 APR 25, 2022 1:28 PM I78300 APR 25, 2022 1:28 PM I78F00 APR 25, 2022 1:28 PM I78700 APR 25, 2022 1:28 PM I70200 APR 25, 2022 1:28 PM LIQUID LABEL DEVICE LABEL 1 UNL 1 STP 2 UNL 1 ANN 3 DSL STP 4 DSL ANN 5 6 PNL ANN 7 UNL 2 STP 8 UNL 2 ANN 9 DISP 1-2 10 DISP 3-4 11 DISP 5-6 12 DISP 7-8 13 TRANS SUMP NO 14 TRANS SUMP SO 15 PNL STP 16 UNL 1 ANN I70300 APR 25, 2022 1:28 PM LIQUID TYPE SENSOR LOCATION TYPE 1 UNL 1 STP TRI-STATE (SINGLE FLOAT) 2 UNL 1 ANN TRI-STATE (SINGLE FLOAT) 3 DSL STP TRI-STATE (SINGLE FLOAT) 4 DSL ANN TRI-STATE (SINGLE FLOAT) 5 TRI-STATE (SINGLE FLOAT) 6 PNL ANN TRI-STATE (SINGLE FLOAT) 7 UNL 2 STP TRI-STATE (SINGLE FLOAT) 8 UNL 2 ANN TRI-STATE (SINGLE FLOAT) 9 DISP 1-2 TRI-STATE (SINGLE FLOAT) 10 DISP 3-4 TRI-STATE (SINGLE FLOAT) 11 DISP 5-6 TRI-STATE (SINGLE FLOAT) 12 DISP 7-8 TRI-STATE (SINGLE FLOAT) 13 TRANS SUMP NO TRI-STATE (SINGLE FLOAT) 14 TRANS SUMP SO TRI-STATE (SINGLE FLOAT) 15 PNL STP TRI-STATE (SINGLE FLOAT) 16 UNL 1 ANN TRI-STATE (SINGLE FLOAT) I70400 APR 25, 2022 1:28 PM LIQUID CATEGORY SENSOR LOCATION CATEGORY 1 UNL 1 STP STP SUMP 2 UNL 1 ANN ANNULAR SPACE 3 DSL STP STP SUMP 4 DSL ANN ANNULAR SPACE 5 OTHER SENSORS 6 PNL ANN ANNULAR SPACE 7 UNL 2 STP STP SUMP 8 UNL 2 ANN ANNULAR SPACE 9 DISP 1-2 DISPENSER PAN 10 DISP 3-4 DISPENSER PAN 11 DISP 5-6 DISPENSER PAN 12 DISP 7-8 DISPENSER PAN 13 TRANS SUMP NO PIPING SUMP 14 TRANS SUMP SO PIPING SUMP 15 PNL STP STP SUMP 16 UNL 1 ANN ANNULAR SPACE I74200 APR 25, 2022 1:28 PM I74300 APR 25, 2022 1:28 PM I74400 APR 25, 2022 1:28 PM I74700 APR 25, 2022 1:28 PM I74800 APR 25, 2022 1:28 PM I74900 APR 25, 2022 1:28 PM I7BC00 APR 25, 2022 1:28 PM I80200 APR 25, 2022 1:28 PM I80300 APR 25, 2022 1:28 PM I80400 APR 25, 2022 1:28 PM I80700 APR 25, 2022 1:28 PM RELAY LABEL DEVICE LABEL 1 UNL 1 2 PNL 3 DSL 4 5 OVERFILL ALARM 6 7 8 I80900 APR 25, 2022 1:28 PM RELAY ORIENTATION RELAY DESIGNATION ORIENTATION 1 UNL 1 NORMALLY OPEN 2 PNL NORMALLY OPEN 3 DSL NORMALLY CLOSED 4 NORMALLY OPEN 5 OVERFILL ALARM NORMALLY OPEN 6 NORMALLY OPEN 7 NORMALLY OPEN 8 NORMALLY OPEN I80B00 APR 25, 2022 1:28 PM RELAY TANK ASSIGNMENT RELAY DESIGNATION TANK 1 UNL 1 1 2 PNL 3 3 DSL NONE 4 NONE 5 OVERFILL ALARM NONE 6 NONE 7 NONE 8 NONE I80A00 APR 25, 2022 1:28 PM RELAY TYPE RELAY DESIGNATION TYPE 1 UNL 1 PUMP CONTROL OUTPUT 2 PNL PUMP CONTROL OUTPUT 3 DSL STANDARD 4 STANDARD 5 OVERFILL ALARM STANDARD 6 STANDARD 7 STANDARD 8 STANDARD I80C00 APR 25, 2022 1:28 PM I80800 APR 25, 2022 1:28 PM RELAY SETUP REPORT R 1:UNL 1 TYPE: PUMP CONTROL OUTPUT TANK #: 1 LIQUID SENSOR ALMS L 1:FUEL ALARM L 7:FUEL ALARM L 9:FUEL ALARM L10:FUEL ALARM L11:FUEL ALARM L12:FUEL ALARM L 1:SENSOR OUT ALARM L 7:SENSOR OUT ALARM L 9:SENSOR OUT ALARM L10:SENSOR OUT ALARM L11:SENSOR OUT ALARM L12:SENSOR OUT ALARM L 1:SHORT ALARM L 7:SHORT ALARM L 9:SHORT ALARM L10:SHORT ALARM L11:SHORT ALARM L12:SHORT ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD VP PRES FAIL ISD VP STATUS FAIL ISD HOSE ALARMS ALL:GROSS COLLECT FAIL ALL:DEGRD COLLECT FAIL ALL:FLOW COLLECT FAIL R 2:PNL TYPE: PUMP CONTROL OUTPUT TANK #: 3 LIQUID SENSOR ALMS L 9:FUEL ALARM L10:FUEL ALARM L11:FUEL ALARM L12:FUEL ALARM L15:FUEL ALARM L 9:SENSOR OUT ALARM L10:SENSOR OUT ALARM L11:SENSOR OUT ALARM L12:SENSOR OUT ALARM L15:SENSOR OUT ALARM L 9:SHORT ALARM L10:SHORT ALARM L11:SHORT ALARM L12:SHORT ALARM L15:SHORT ALARM ISD SITE ALARMS ISD GROSS PRES FAIL ISD DEGRD PRES FAIL ISD VAPOR LEAK FAIL ISD VP PRES FAIL ISD VP STATUS FAIL ISD HOSE ALARMS ALL:GROSS COLLECT FAIL ALL:DEGRD COLLECT FAIL ALL:FLOW COLLECT FAIL R 3:DSL TYPE: STANDARD NORMALLY CLOSED TANK #: NONE LIQUID SENSOR ALMS L 3:FUEL ALARM L 9:FUEL ALARM L10:FUEL ALARM L11:FUEL ALARM L12:FUEL ALARM L13:FUEL ALARM L14:FUEL ALARM L 3:SENSOR OUT ALARM L 9:SENSOR OUT ALARM L10:SENSOR OUT ALARM L11:SENSOR OUT ALARM L12:SENSOR OUT ALARM L13:SENSOR OUT ALARM L14:SENSOR OUT ALARM L 3:SHORT ALARM L 9:SHORT ALARM L10:SHORT ALARM L11:SHORT ALARM L12:SHORT ALARM L13:SHORT ALARM L14:SHORT ALARM R 4: TYPE: STANDARD NORMALLY OPEN TANK #: NONE - NO ALARM ASSIGNMENTS - R 5:OVERFILL ALARM TYPE: STANDARD NORMALLY OPEN TANK #: NONE IN-TANK ALARMS ALL:OVERFILL ALARM ALL:HIGH PRODUCT ALARM ALL:MAX PRODUCT ALARM R 6: TYPE: STANDARD NORMALLY OPEN TANK #: NONE - NO ALARM ASSIGNMENTS - R 7: TYPE: STANDARD NORMALLY OPEN TANK #: NONE - NO ALARM ASSIGNMENTS - R 8: TYPE: STANDARD NORMALLY OPEN TANK #: NONE - NO ALARM ASSIGNMENTS - I79000 APR 25, 2022 1:29 PM EDIM:1 VR:349634-003-C TD:06.05.11.11.15 I79100 APR 25, 2022 1:29 PM I72300 APR 25, 2022 1:29 PM FASTRIP 347 2698 OSWELL ST BAKERSFIELD 93306 661-872-8721 SMARTSENSOR ASSIGNMENT DEVICE LABEL CATEGORY 01 PS 3-4 VAPOR PRESSURE 02 FM 1-2 AIR FLOW METER 03 FM 3-4 AIR FLOW METER 04 FM 5-6 AIR FLOW METER 05 FM 7-8 AIR FLOW METER 06 UNKNOWN 07 UNKNOWN 08 UNKNOWN 09 UNKNOWN 10 UNKNOWN 11 UNKNOWN 12 UNKNOWN 13 UNKNOWN 14 UNKNOWN 15 UNKNOWN 16 UNKNOWN 17 UNKNOWN 18 UNKNOWN 19 UNKNOWN 20 UNKNOWN 21 UNKNOWN 22 UNKNOWN 23 UNKNOWN 24 UNKNOWN 25 UNKNOWN 26 UNKNOWN 27 UNKNOWN 28 UNKNOWN 29 UNKNOWN 30 UNKNOWN 31 UNKNOWN 32 UNKNOWN 33 UNKNOWN 34 UNKNOWN 35 UNKNOWN 36 UNKNOWN 37 UNKNOWN 38 UNKNOWN 39 UNKNOWN 40 UNKNOWN IV4E00 APR 25, 2022 1:29 PM FASTRIP 347 2698 OSWELL ST BAKERSFIELD 93306 661-872-8721 EVR/ISD SETUP TYPE: VACUUM ASSIST VACUUM ASSIST TYPE: HEALY VAC IV4F00 APR 25, 2022 1:29 PM FASTRIP 347 2698 OSWELL ST BAKERSFIELD 93306 661-872-8721 NOZZLE A/L RANGE A/L RATIO: 0.95 - 1.15 IV4000 APR 25, 2022 1:29 PM FASTRIP 347 2698 OSWELL ST BAKERSFIELD 93306 661-872-8721 VAPOR PROCESSOR TYPE NONE IV4700 APR 25, 2022 1:29 PM FASTRIP 347 2698 OSWELL ST BAKERSFIELD 93306 661-872-8721 ASSESSMENT TIME START TIME: 10:00 AM TIME DELAY MINUTES: 1 IV5200 APR 25, 2022 1:29 PM FASTRIP 347 2698 OSWELL ST BAKERSFIELD 93306 661-872-8721 ACCEPT HIGH ORVR: YES IV4A00 APR 25, 2022 1:29 PM FASTRIP 347 2698 OSWELL ST BAKERSFIELD 93306 661-872-8721 ISD HOSE TABLE HOSE FP FP AFM REL HOSE ID ID LABEL ID ID LABEL 01 01 01 01 02 BLEND3 02 02 02 01 02 BLEND3 03 03 03 02 02 BLEND3 04 04 04 02 02 BLEND3 05 05 05 03 02 BLEND3 06 06 06 03 02 BLEND3 07 07 07 04 02 BLEND3 08 08 08 04 02 BLEND3 IV4B00 APR 25, 2022 1:29 PM FASTRIP 347 2698 OSWELL ST BAKERSFIELD 93306 661-872-8721 PRODUCT/HOSE MAP TABLE FP AFID M1/H1 M2/H2 M3/H3 M4/H4 01 01 02/01 03/01 09/01 xx/xx 02 01 02/02 03/02 09/02 xx/xx 03 02 02/03 03/03 09/03 xx/xx 04 02 02/04 03/04 09/04 xx/xx 05 03 02/05 03/05 09/05 xx/xx 06 03 02/06 03/06 09/06 xx/xx 07 04 02/07 03/07 09/07 xx/xx 08 04 02/08 03/08 09/08 xx/xx IV4900 APR 25, 2022 1:29 PM FASTRIP 347 2698 OSWELL ST BAKERSFIELD 93306 661-872-8721 LABEL TABLE ID LABEL 01 UNASSIGNED 02 BLEND3 03 REGULAR 04 MID GRADE 05 PREMIUM 06 GOLD 07 BRONZE 08 SILVER 09 BLEND2 10 BLEND4 IV1000 APR 25, 2022 1:29 PM ISD VERSION: 01.07 Alarm History After. Responses Received: I10200 APR 25, 2022 1:30 PM FASTRIP 347 2698 OSWELL ST BAKERSFIELD 93306 661-872-8721 SYSTEM CONFIGURATION SLOT BOARD TYPE POWER ON RESET CURRENT 1 8SMARTSENSOR BD 39557 39522 2 4 PROBE / G.T. 163015 162818 3 INTERSTITIAL BD 201752 201490 4 INTERSTITIAL BD 201230 200965 5 UNUSED 4944149 4927839 6 UNUSED 4941027 4925544 7 UNUSED 4939812 4924976 8 UNUSED 4938848 4924576 9 STP SENSE BOARD 33158 33152 10 RELAY BOARD 14944 14979 11 RELAY BOARD 14923 14915 12 UNUSED 4940499 4930061 13 UNUSED 4941316 4927535 14 UNUSED 4940436 4927114 15 UNUSED 4937880 4926945 16 UNUSED 4940457 4927977 COMM 1 ELEC DISP INT. 100495 100461 COMM 2 RS232 SERIAL BD 14902 14936 COMM 3 RS232 SERIAL BD 15007 15000 COMM 4 UNUSED 4943055 4929576 COMM 5 UNUSED 4939032 4927198 COMM 6 UNUSED 4939472 4927493 I90200 APR 25, 2022 1:30 PM SOFTWARE REVISION LEVEL VERSION 336.02 SOFTWARE# 346336-100-C CREATED - 21.02.13.11.53 S-MODULE# 330160-004-a SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS ISD/APM I11100 APR 25, 2022 1:30 PM FASTRIP 347 2698 OSWELL ST BAKERSFIELD 93306 661-872-8721 PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME L 1 STP SUMP UNL 1 STP SENSOR OUT ALARM CLEAR 4-25-22 1:12PM L 3 STP SUMP DSL STP SENSOR OUT ALARM CLEAR 4-25-22 1:12PM L 7 STP SUMP UNL 2 STP SENSOR OUT ALARM CLEAR 4-25-22 1:12PM L 8 ANNULAR UNL 2 ANN SENSOR OUT ALARM CLEAR 4-25-22 1:12PM L 2 ANNULAR UNL 1 ANN SENSOR OUT ALARM CLEAR 4-25-22 1:12PM L 6 ANNULAR PNL ANN SENSOR OUT ALARM CLEAR 4-25-22 1:12PM L 4 ANNULAR DSL ANN SENSOR OUT ALARM CLEAR 4-25-22 1:12PM L15 STP SUMP PNL STP SENSOR OUT ALARM CLEAR 4-25-22 1:12PM L12 DISP PAN DISP 7-8 SENSOR OUT ALARM CLEAR 4-25-22 1:12PM L14 PIPE TRANS SUMP SO SENSOR OUT ALARM CLEAR 4-25-22 1:12PM L11 DISP PAN DISP 5-6 SENSOR OUT ALARM CLEAR 4-25-22 1:12PM L13 PIPE TRANS SUMP NO SENSOR OUT ALARM CLEAR 4-25-22 1:12PM L10 DISP PAN DISP 3-4 SENSOR OUT ALARM CLEAR 4-25-22 1:12PM L 9 DISP PAN DISP 1-2 SENSOR OUT ALARM CLEAR 4-25-22 1:12PM L11 DISP PAN DISP 5-6 SENSOR OUT ALARM ALARM 4-25-22 1:12PM L10 DISP PAN DISP 3-4 SENSOR OUT ALARM ALARM 4-25-22 1:12PM L 8 ANNULAR UNL 2 ANN SENSOR OUT ALARM ALARM 4-25-22 1:12PM L 9 DISP PAN DISP 1-2 SENSOR OUT ALARM ALARM 4-25-22 1:12PM L15 STP SUMP PNL STP SENSOR OUT ALARM ALARM 4-25-22 1:12PM L 7 STP SUMP UNL 2 STP SENSOR OUT ALARM ALARM 4-25-22 1:12PM L14 PIPE TRANS SUMP SO SENSOR OUT ALARM ALARM 4-25-22 1:12PM L 4 ANNULAR DSL ANN SENSOR OUT ALARM ALARM 4-25-22 1:12PM L13 PIPE TRANS SUMP NO SENSOR OUT ALARM ALARM 4-25-22 1:12PM L 6 ANNULAR PNL ANN SENSOR OUT ALARM ALARM 4-25-22 1:12PM L 3 STP SUMP DSL STP SENSOR OUT ALARM ALARM 4-25-22 1:12PM L12 DISP PAN DISP 7-8 SENSOR OUT ALARM ALARM 4-25-22 1:12PM L 2 ANNULAR UNL 1 ANN SENSOR OUT ALARM ALARM 4-25-22 1:12PM L 1 STP SUMP UNL 1 STP SENSOR OUT ALARM ALARM 4-25-22 1:12PM L13 PIPE TRANS SUMP NO FUEL ALARM CLEAR 4-25-22 1:12PM L13 PIPE TRANS SUMP NO FUEL ALARM ALARM 4-25-22 1:11PM L14 PIPE TRANS SUMP SO FUEL ALARM CLEAR 4-25-22 1:11PM L14 PIPE TRANS SUMP SO FUEL ALARM ALARM 4-25-22 1:11PM L12 DISP PAN DISP 7-8 FUEL ALARM CLEAR 4-25-22 1:10PM L12 DISP PAN DISP 7-8 FUEL ALARM ALARM 4-25-22 1:10PM L 8 ANNULAR UNL 2 ANN FUEL ALARM CLEAR 4-25-22 1:03PM L 8 ANNULAR UNL 2 ANN FUEL ALARM ALARM 4-25-22 1:03PM L 2 ANNULAR UNL 1 ANN FUEL ALARM CLEAR 4-25-22 1:02PM L 2 ANNULAR UNL 1 ANN FUEL ALARM ALARM 4-25-22 1:02PM L 4 ANNULAR DSL ANN FUEL ALARM CLEAR 4-25-22 1:02PM L 6 ANNULAR PNL ANN FUEL ALARM CLEAR 4-25-22 1:02PM L 4 ANNULAR DSL ANN FUEL ALARM ALARM 4-25-22 1:02PM L 6 ANNULAR PNL ANN FUEL ALARM ALARM 4-25-22 1:01PM L10 DISP PAN DISP 3-4 FUEL ALARM CLEAR 4-25-22 1:00PM L10 DISP PAN DISP 3-4 FUEL ALARM ALARM 4-25-22 1:00PM L 9 DISP PAN DISP 1-2 FUEL ALARM CLEAR 4-25-22 12:59PM L 9 DISP PAN DISP 1-2 FUEL ALARM ALARM 4-25-22 12:59PM L12 DISP PAN DISP 7-8 FUEL ALARM CLEAR 4-25-22 12:58PM L12 DISP PAN DISP 7-8 FUEL ALARM ALARM 4-25-22 12:58PM L 7 STP SUMP UNL 2 STP FUEL ALARM CLEAR 4-25-22 12:57PM L 7 STP SUMP UNL 2 STP FUEL ALARM ALARM 4-25-22 12:57PM I11200 APR 25, 2022 1:30 PM FASTRIP 347 2698 OSWELL ST BAKERSFIELD 93306 661-872-8721 NON-PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME I20600 APR 25, 2022 1:30 PM FASTRIP 347 2698 OSWELL ST BAKERSFIELD 93306 661-872-8721 TANK ALARM HISTORY TANK 1 UNL 1 TANK 2 DIESEL TANK 3 PNL TANK 4 UNL 2 TANK 5 TANK 6 TANK 7 TANK 8 TANK 9 TANK 10 TANK 11 TANK 12 TANK 13 TANK 14 TANK 15 TANK 16 I38200 APR 25, 2022 1:30 PM I30200 APR 25, 2022 1:30 PM FASTRIP 347 2698 OSWELL ST BAKERSFIELD 93306 661-872-8721 LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 UNL 1 STP APR 25, 2022 1:12 PM SENSOR OUT ALARM APR 25, 2022 12:55 PM FUEL ALARM 2 UNL 1 ANN APR 25, 2022 1:12 PM SENSOR OUT ALARM APR 25, 2022 1:02 PM FUEL ALARM 3 DSL STP APR 25, 2022 1:12 PM SENSOR OUT ALARM APR 25, 2022 12:54 PM FUEL ALARM 4 DSL ANN APR 25, 2022 1:12 PM SENSOR OUT ALARM APR 25, 2022 1:02 PM FUEL ALARM 6 PNL ANN APR 25, 2022 1:12 PM SENSOR OUT ALARM APR 25, 2022 1:01 PM FUEL ALARM 7 UNL 2 STP APR 25, 2022 1:12 PM SENSOR OUT ALARM APR 25, 2022 12:57 PM FUEL ALARM 8 UNL 2 ANN APR 25, 2022 1:12 PM SENSOR OUT ALARM APR 25, 2022 1:03 PM FUEL ALARM 9 DISP 1-2 APR 25, 2022 1:12 PM SENSOR OUT ALARM APR 25, 2022 12:59 PM FUEL ALARM 10 DISP 3-4 APR 25, 2022 1:12 PM SENSOR OUT ALARM APR 25, 2022 1:00 PM FUEL ALARM 11 DISP 5-6 APR 25, 2022 1:12 PM SENSOR OUT ALARM APR 25, 2022 12:56 PM FUEL ALARM 12 DISP 7-8 APR 25, 2022 1:12 PM SENSOR OUT ALARM APR 25, 2022 1:10 PM FUEL ALARM APR 25, 2022 12:58 PM FUEL ALARM 13 TRANS SUMP NO APR 25, 2022 1:12 PM SENSOR OUT ALARM APR 25, 2022 1:11 PM FUEL ALARM 14 TRANS SUMP SO APR 25, 2022 1:12 PM SENSOR OUT ALARM APR 25, 2022 1:11 PM FUEL ALARM 15 PNL STP APR 25, 2022 1:12 PM SENSOR OUT ALARM APR 25, 2022 12:53 PM FUEL ALARM I31600 APR 25, 2022 1:30 PM FASTRIP 347 2698 OSWELL ST BAKERSFIELD 93306 661-872-8721 SMART SENSOR ALARM HISTORY REPORT SENSOR LOCATION 1 PS 3-4 2 FM 1-2 3 FM 3-4 4 FM 5-6 5 FM 7-8 I40200 APR 25, 2022 1:30 PM I40300 APR 25, 2022 1:30 PM I34200 APR 25, 2022 1:30 PM I34700 APR 25, 2022 1:30 PM IV0100 APR 25, 2022 1:30 PM FASTRIP 347 2698 OSWELL ST BAKERSFIELD 93306 661-872-8721 ISD ALARM STATUS REPORT EVR TYPE: VACUUM ASSIST ISD TYPE: 01.07 VAPOR PROCESSOR TYPE: NONE OVERALL STATUS :PASS EVR VAPOR COLLECTION :PASS EVR VAPOR CONTAINMENT :PASS ISD MONITOR UP-TIME :100% EVR/ISD PASS TIME :100% WARNING ALARMS DATE TIME DESCRIPTION READING VALUE 22-04-23 10:01:09 A/L RATIO DEGRADATION FP 1 BLEND3 0.80 22-04-19 10:01:09 A/L RATIO DEGRADATION FP 2 BLEND3 BLKD 22-04-18 10:01:09 SENSOR OUT SELFTEST CHECK VAPOR FLOW METER f 1:FM 1-2 22-04-18 10:01:09 A/L RATIO GROSS BLOCKAGE FP 2 BLEND3 BLKD 22-04-17 10:01:09 SENSOR OUT SELFTEST CHECK VAPOR FLOW METER f 1:FM 1-2 22-04-17 10:01:09 A/L RATIO DEGRADATION FP 4 BLEND3 0.78 22-04-16 10:01:09 A/L RATIO DEGRADATION FP 4 BLEND3 0.79 22-04-03 10:01:09 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 16.62 22-03-31 10:01:09 VAPOR CONTAINMENT LEAKAGE CFH@2 INCHES WC 8.85 22-03-29 10:01:09 A/L RATIO DEGRADATION FP 6 BLEND3 0.76 FAILURE ALARMS DATE TIME DESCRIPTION READING VALUE 22-04-19 10:01:09 A/L RATIO GROSS BLOCKAGE FP 2 BLEND3 BLKD 15-12-16 10:01:58 A/L RATIO GROSS BLOCKAGE FP 8 BLEND3 BLKD 15-12-16 10:01:58 A/L RATIO GROSS BLOCKAGE FP 7 BLEND3 BLKD 15-12-15 10:01:56 A/L RATIO GROSS BLOCKAGE FP 8 BLEND3 BLKD 12-08-18 10:02:49 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 2.70 11-08-25 10:02:34 CONTAINMENT GROSS OVER PRESSURE WEEKLY 95% 2.05 SHUTDOWN & MISCELLANEOUS EVENTS DATE TIME DESCRIPTION ACTION/NAME 22-04-25 13:13:00 READINESS ISD:PF EVR:NNN CHECK ISD SENSORS 22-04-25 13:13:00 ISD STARTUP 22-04-25 13:12:56 ISD SHUTDOWN 22-04-25 12:46:00 TIME CHANGE DETECTED AT: 22-04-25 08:10:27 22-04-25 08:10:18 TIME CHANGE DETECTED AT: 21-02-13 08:10:17 22-04-19 17:09:19 COLLECTION TEST HH02 GRADE TEST MANUALLY CLEARED 22-04-19 11:18:05 PUMPS MANUALLY RE-ENABLED 22-04-19 10:01:09 A/L RATIO GROSS BLOCKAGE DISABLED FP 02 BLEND3 22-03-29 11:14:36 COLLECTION TEST HH06 GRADE TEST MANUALLY CLEARED 22-03-29 11:14:27 COLLECTION TEST HH06 GRADE TEST MANUALLY CLEARED