Loading...
HomeMy WebLinkAbout06-30-22 Bakersfield Police Department - Overfill Appendix IX Underground Storage Tank Overfill Prevention Equipment Inspection Report Form CERS = California Environmental Reporting System, ID = Identification, ICC = International Code Council, OPE = Overfill Prevention Equipment Page 1 of 2 TYPE OF ACTION ☐ Installation ☐ Repair ☐ 36 Month 1. FACILITY INFORMATION CERS ID Inspection Date Facility Name Facility Address City ZIP Code 2. SERVICE TECHNICIAN INFORMATION Company Performing the Inspection Phone Mailing Address Service Technician Performing Inspection Contractor/Tank Tester License Number ICC Number Expiration Date 3. TRAINING AND CERTIFICATIONS Manufacturer and Test Equipment Training Certifications Expiration Date 4. INSPECTION PROCEDURES INFORMATION Inspection Procedures Used Components Inspected 5. CERTIFICATION BY SERVICE TECHNICIAN CONDUCTING INSPECTION I hereby certify that the OPE was inspected in accordance with California Code of Regulations, title 23, division 3, chapter 16, section 2637.2; that required supporting documentation is attached; and all information contained herein is accurate. I understand that test procedures shall be made available upon request by the governing authority. Service Technician Signature Date Total # of Pages Underground Storage Tank Overfill Prevention Equipment Inspection Report Additional copies of this page may be attached. Attach tank chart(s), measurements, calculations, and In-Tank Setup report(s) Page 2 of 2 6. OVERFILL PREVENTION EQUIPMENT DETAILS Tank ID (one OPE per column) Are both vent and tank riser piping secondarily contained? ☐ Yes ☐ No ☐ Yes ☐ No ☐ Yes ☐ No ☐ Yes ☐ No OPE Model What is the OPE response when activated? (Check all that apply.) ☐ Shut off Flow ☐Restricts Flow ☐ Audible Alarm ☐ Visual Alarm ☐ Shut off Flow ☐Restricts Flow ☐ Audible Alarm ☐ Visual Alarm ☐ Shut off Flow ☐Restricts Flow ☐ Audible Alarm ☐ Visual Alarm ☐ Shut off Flow ☐Restricts Flow ☐ Audible Alarm ☐ Visual Alarm Are flow restrictors installed on vent piping that may interfere with the OPE operation? ☐ Yes* ☐ No ☐ Yes* ☐ No ☐ Yes* ☐ No ☐ Yes* ☐ No At what level in the tank is the OPE set to activate? (Inches from bottom of tank) What is the percent capacity of the tank at which the OPE activates? Is the OPE in proper operating condition to respond when the stored substance reaches the designated regulatory level? ☐ Yes ☐ No ☐ Yes ☐ No ☐ Yes ☐ No ☐ Yes ☐ No 7. SUMMARY OF TESTING RESULTS OPE Inspection Results ☐ Pass ☐ Fail ☐ Pass ☐ Fail ☐ Pass ☐ Fail ☐ Pass ☐ Fail 1 8. COMMENTS Describe all results marked “Fail” and each proposed remedy. * Mark here if: ☐ Flow restrictors interfere with overfill prevention and equipment repairs required. Check (A) on tank chart Flapper Depth (D) In-Tank Activation Height H - D = (A) Product Tank Diameter (T) Riser Height (R) Tank 3Tank 2Tank 1 Overfill Prevention Calculations Form Tank 4 Measurements Calculation Total Height T + R = (H) * This form and the tank charts must be submitted with test results form Tank full volume (V) Find percent (A) x 100 ÷ (V) Modern Welding Company Subsidiaries Nationwide www.modweldco.com modern@modweldco.com Tank Calibration Chart Cylindrical Tank / Horizontal Orientation Striker Plate: 0 inches Diameter: 119.75 inches Length: 303.25 inches Total Volume: 14,785 gallons Depth (inches) Volume (gallons) 0.000 0 0.500 7 1.000 19 1.500 35 2.000 54 2.500 75 3.000 99 3.500 124 4.000 152 4.500 181 5.000 211 5.500 244 6.000 277 6.500 312 7.000 348 7.500 386 8.000 425 8.500 464 9.000 505 9.500 547 10.000 590 10.500 634 11.000 679 11.500 725 12.000 772 12.500 819 13.000 868 13.500 917 14.000 967 14.500 1,018 15.000 1,070 15.500 1,122 16.000 1,175 16.500 1,229 Depth (inches) Volume (gallons) 17.000 1,284 17.500 1,339 18.000 1,395 18.500 1,451 19.000 1,509 19.500 1,566 20.000 1,625 20.500 1,684 21.000 1,743 21.500 1,803 22.000 1,864 22.500 1,925 23.000 1,987 23.500 2,049 24.000 2,111 24.500 2,175 25.000 2,238 25.500 2,302 26.000 2,367 26.500 2,432 27.000 2,497 27.500 2,563 28.000 2,630 28.500 2,696 29.000 2,764 29.500 2,831 30.000 2,899 30.500 2,967 31.000 3,036 31.500 3,105 32.000 3,174 32.500 3,244 33.000 3,314 33.500 3,385 Depth (inches) Volume (gallons) 34.000 3,455 34.500 3,526 35.000 3,598 35.500 3,669 36.000 3,741 36.500 3,814 37.000 3,886 37.500 3,959 38.000 4,032 38.500 4,105 39.000 4,179 39.500 4,253 40.000 4,327 40.500 4,401 41.000 4,475 41.500 4,550 42.000 4,625 42.500 4,700 43.000 4,775 43.500 4,851 44.000 4,927 44.500 5,002 45.000 5,079 45.500 5,155 46.000 5,231 46.500 5,308 47.000 5,384 47.500 5,461 48.000 5,538 48.500 5,615 49.000 5,692 49.500 5,770 50.000 5,847 50.500 5,925 Depth (inches) Volume (gallons) 51.000 6,003 51.500 6,080 52.000 6,158 52.500 6,236 53.000 6,314 53.500 6,392 54.000 6,471 54.500 6,549 55.000 6,627 55.500 6,705 56.000 6,784 56.500 6,862 57.000 6,941 57.500 7,019 58.000 7,098 58.500 7,177 59.000 7,255 59.500 7,334 60.000 7,412 60.500 7,491 61.000 7,569 61.500 7,648 62.000 7,727 62.500 7,805 63.000 7,884 63.500 7,962 64.000 8,041 64.500 8,119 65.000 8,197 65.500 8,276 66.000 8,354 66.500 8,432 67.000 8,510 67.500 8,588 Depth (inches) Volume (gallons) 68.000 8,666 68.500 8,744 69.000 8,822 69.500 8,899 70.000 8,977 70.500 9,054 71.000 9,131 71.500 9,209 72.000 9,286 72.500 9,363 73.000 9,439 73.500 9,516 74.000 9,592 74.500 9,669 75.000 9,745 75.500 9,821 76.000 9,897 76.500 9,972 77.000 10,048 77.500 10,123 78.000 10,198 78.500 10,273 79.000 10,347 79.500 10,422 80.000 10,496 80.500 10,570 81.000 10,643 81.500 10,717 82.000 10,790 82.500 10,863 83.000 10,935 83.500 11,008 84.000 11,080 84.500 11,152 Depth (inches) Volume (gallons) 85.000 11,223 85.500 11,294 86.000 11,365 86.500 11,436 87.000 11,506 87.500 11,576 88.000 11,646 88.500 11,715 89.000 11,784 89.500 11,852 90.000 11,920 90.500 11,988 91.000 12,055 91.500 12,122 92.000 12,189 92.500 12,255 93.000 12,321 93.500 12,386 94.000 12,451 94.500 12,515 95.000 12,579 95.500 12,642 96.000 12,705 96.500 12,768 97.000 12,830 97.500 12,891 98.000 12,952 98.500 13,012 99.000 13,072 99.500 13,131 100.00013,190 100.50013,248 101.00013,305 101.50013,362 Depth (inches) Volume (gallons) 102.00013,418 102.50013,474 103.00013,529 103.50013,583 104.00013,636 104.50013,689 105.00013,741 105.50013,793 106.00013,843 106.50013,893 107.00013,942 107.50013,990 108.00014,037 108.50014,083 109.00014,129 109.50014,173 110.00014,217 110.50014,259 111.00014,301 111.50014,341 112.00014,380 112.50014,418 113.00014,455 113.50014,491 114.00014,525 114.50014,558 115.00014,589 115.50014,619 116.00014,648 116.50014,674 117.00014,699 117.50014,721 118.00014,741 118.50014,759 Page 1 of 2 This volumetric tank chart is supplied to you for informational purposes only. These capacity calculations are based on theoretical volumes not actual volumes, and do not reflect atmospheric conditions or thermal expansion/contraction due to temperature changes. If internal accessories such as pumps are present, displacement of these accessories must be considered. Therefore, neither Modern Welding Company nor its officers, directors, employee affiliates or subsidiaries shall be liable for the use of this information covered within. This information is advisory only and the use of the material and methods is solely at the risk of the user. Depth (inches) Volume (gallons) 119.00014,773 119.50014,783 Cylindrical Tank / Horizontal Orientation Striker Plate: 0 inches | Diameter: 119.75 inches | Length: 303.25 inches | Total Volume: 14,785 gallons