Loading...
HomeMy WebLinkAbout1200 Oregon Street SENTVIAUSMAILANDELECTRONICMAIL July12,2022 FranklinCastillo 1715S.ArapahoeStreet LosAngeles,CA90006 RE:NoticeofDecisionSitePlanReview(ProjectNo.220279)(Ward2) DearMr.Castillo: Theplansforconstructionof2,098squarefootduplexonaparcelwithanexistingsinglefamilyresidenceinanR 3(LimitedMultipleFamilyDwellingZone)districtlocatedat1200OregonStreethavebeenreviewedbytheSite PlanReviewCommitteeanditemsrequiringyourattentionareattached. Oncethecorrectionsnotedintheattachedsiteplancompliancelisthavebeenmade,theproposalwillmeetthe minimumrequiredcodes,policiesandstandardsfordevelopmentasadoptedbytheBakersfieldCityCouncil. Specificitemshavebeenidentified(seeattachedSitePlanComplianceList)thatyouneedtoresolvebeforeyou canobtainabuildingpermitorbeallowedoccupancy.Theseitemsmayincludechangesoradditionsthatneed tobeshownonthefinalbuildingplans,alertyoutospecificfees,and/orarecommentsthatwillhelpyouin complyingwiththeĭźƷǤ͸ƭdevelopmentstandards.Eachitemwillnotewhenitistobecompletedandtheyhave beengroupedbydepartmentsothatyouknowwhomtocontactifyouhavequestions. Yournextstepistoeitherapplyfornecessarybuildingpermitstoconstructyourproject,orbeginyourbusiness activitiesdependingontherequestsubmitted.YoumustsubmitfinalbuildingplanstotheBuildingDivision.The SitePlanReviewCommitteewillreviewthesefinalplanswhilebuildingplancheckoccurstoensurethatyousatisfy theitemsintheSitePlanComplianceList.Pleasereadthemcarefully.Failuretosatisfyanitemmaydelayyour obtainingabuildingpermitorcommencingyourproject. AfterconstructionofyourprojectbutbeforetheCitycanallowoccupancy,theBuildingDivisionmustinspectthe developmenttofindifitcomplieswiththeapprovedplans,andanyotherrelevantpermitsandcodes.Ifyouhave satisfiedalloftherequirements,theBuildingDirectorwillissueacertificateofoccupancy;ifnot,theareainspector willgiveyouacorrectionnotice.Onceyouhavemadeallofthecorrections,theBuildingDirectorcanissuea certificateofoccupancy.YoumaynotoccupyadevelopmentuntiltheBuildingDirectorhasissuedacertificateof occupancy. INDEMNIFICATIONCONDITION InconsiderationbytheCityofBakersfieldforlanduseentitlements,includingbutnotlimitedtorelated environmentalapprovalsrelatedtoorarisingfromthisproject,theapplicant,and/orpropertyownerand/or subdividerΛͻ!ƦƦƌźĭğƓƷͼherein)agreestoindemnify,defend,andholdharmlesstheCityofBakersfield,itsofficers, agents,employees,departments,commissionersandboardsΛͻ/źƷǤͼherein)againstanyandallliability,claims, actions,causesofactionsordemandswhatsoeveragainstthem,oranyofthem,beforeadministrativeorjudicial tribunalsofanykindwhatsoever,inanywayarisingfrom,thetermsandprovisionsofthisapplication,including withoutlimitationanyCEQAapprovaloranyrelateddevelopmentapprovalsorconditionswhetherimposedby theCity,ornot,exceptfor/źƷǤ͸ƭsoleactivenegligenceorwillfulmisconduct. ThisindemnificationconditiondoesnotpreventtheApplicantfromchallenginganydecisionbytheCityrelatedto thisprojectandtheobligationsofthisconditionapplyregardlessofwhetheranyotherpermitsorentitlements areissued. TheCitywillpromptlynotifyApplicantofanysuchclaim,action,orproceeding,failingunderthisconditionwithin thirty(30)daysofactuallyreceivingsuchclaim.TheCity,initssolediscretion,shallbeallowedtochoosethe attorneyoroutsidelawfirmtodefendtheCityatthesolecostandexpenseoftheApplicantandtheCityisnot obligatedtouseanylawfirmorattorneychosenbyanotherentityorparty. REVISIONSTOTHEAPPROVEDPLAN Anytimeaftersiteplanapprovalbutbeforetheapprovalexpires,youmaysubmitrevisionstotheplan.Wewilltreat theserevisionsasanewsiteplanapplicationsubjecttoanewreviewandrequiredfees.ThePlanningDirectorcanonly approveminorchangestotheoriginalplanwithoutanewapplicationiftheyarenecessarytomeetacondition, mitigation,orresultfromphysicalobstaclesorothercomparableconstraints(SeeSection17.08.080.c.3oftheZoning Ordinance). EXPIRATIONOFPLANS Thissiteplanexpireson July11,2024(2yearsfromthedecisiondate),unlessbuildingpermitshavebeenissued, orwheretheusehascommencedonprojectsnotrequiringabuildingpermit.Theprojectmustbecompleted within5yearsfromthedecisiondate.Ifthepropertyisrezoned,siteplanapprovalwillexpireupontheeffective datefortherezoningunlesstheuseispermittedinthenewzone. ThePlanningDirectormayextendtheexpirationdateuptoone(1)yearifyouresubmitnewplansforcheck againstthecoderequirementsineffectatthattimeandincludeawrittenrequestfortheextension.Wemust receivethisrequest before expirationoftheprojectapproval.Wewillnotrequireafeeforthisextensionrequest; however,changestotheplansoriginallyapprovedforpurposesotherthancoderequirementsshallbesubjectto anewsiteplanreview,includingpaymentofallrequiredfees(SeeSection17.08.080.DoftheZoningOrdinance). ENVIRONMENTALDETERMINATION ThissiteplanreviewhasbeenfoundtobeexemptfromtheprovisionsoftheCaliforniaEnvironmentalQualityAct (CEQA)accordingtoSection15332.Thisprojectisexemptbecauseitisaninfilldevelopmentthatisconsistentwiththe generalplanandzoningregulations,iswithinanareapredominantlydevelopedwithurbanuses,isnotidentifiedas criticalhabitatforendangeredorthreatenedspecies,willnotsignificantlyaffecttrafficnoise,airorwaterquality,and willbeadequatelyservedbyappropriateutilitiesandpublicservices.ANoticeofExemptionhasbeenpreparedandis availableforreviewatthePlanningDivision. SPR220279Page|2of11 APPEAL Anypersonmayappealthisdecision.Anappealislimitedtowhetherornotanadopteddevelopmentstandard, zoningregulation,mitigation,orpolicyappliedornotappliedtotheproject,wasdoneconsistentwiththe authoritygrantedbycityordinancesortheCaliforniaEnvironmentalQualityAct(CEQA).Theappealmustbein ingtheprecisebasisorissueasnoted,mustincludetheappropriatefilingfee,andmustbefiledwithin writingstat 10days ofthedecisiondatetotheCityofBakersfieldPlanningCommission(c/oBakersfieldPlanningDirector, 1715ChesterAvenue,Bakersfield,CA93301).ThePlanningCommissionwillholdapublichearingontheappeal andtheirdecisionwillbefinalunlesstheirdecisionisappealedtotheCityCouncil. Siteplanapprovalisbasedonthestatementsmadeintheapplicationandtheplansyousubmitted.Anyerrorsor omissionsontheseplanscouldalterthecompliancelistand/orvoidthisdecision.Ifyouhavequestionsabout anyoftheitemsnotedintheSitePlanComplianceList,youmustspeaktothecontactpersonrepresentingthe departmentrequiringthatitem. Correspondencewillcontinuetobesenttotheapplicantonrecord.Shouldtheapplicantchange,itistheproperty ƚǞƓĻƩ͸ƭresponsibilitytoupdatethecontactinformationwiththePlanningDivision.Ifyouhaveotherquestions regardinggeneralinformationaboutthesiteplanreviewprocess,pleasecontactthePlanningDivisionat(661) 3263733. DECISIONDATE:July12,2022 Sincerely, LindaMitchell PrincipalPlanner 9ƓĭƌƚƭǒƩĻ cc:AllInterestedAgenciesΑForyourrecords. S:\\CounterOperations\\01_SPR\\2022\\220279_1200OregonStreet_duplex\\sprltr.docx SPR220279Page|3of11 CONDITIONSANDORDINANCECOMPLIANCE Thefollowingarespecificitemsthatyouneedtoresolvebeforeyoucanobtainabuildingpermitorbeallowed occupancy.Theseitemsincludeconditionsand/ormitigationrequiredbyprevioussiteentitlementapprovals (thesewillbespecificallynoted),changesoradditionsthatneedtobeshownonthefinalbuildingplans,alert youtospecificfees,andotherconditionsforyourprojecttosatisfythe/źƷǤ͸ƭdevelopmentstandards. Theitemslistedbelowwillusuallyneedtobeshownonthefinalbuildingplansorcompletedbeforeabuilding permitisissued.Aspartofthebuildingpermitsubmittal,identifythelocationofyourresponsebyusingthe !tt\[L/!b͸{RESPONSE lineprovideddirectlybelowtheitem(example:sheetnumber,detail,etc.). A.DEVELOPMENTSERVICESBUILDING(1715ChesterAvenue) (StaffcontactOscarFuentes;6613263676orOFuentes@bakersfieldcity.us) 1.Showonthefinalbuildingplanhowandwherewaterwillbedrainedfromtheproperty. !tt\[L/!b͸{RESPONSE:__________________________________________________________ 2.Thedevelopershallincludefireresistivewallconstructiondetailswiththefinalbuildingplansfor allexteriorwallsofanybuildingthatiswithinthedistanceassetforthinTable602oftheCalifornia BuildingCode. !tt\[L/!b͸{RESPONSE:__________________________________________________________ 3.Buildingsorstructuresshallrequireinstallationofanautomaticfiresprinklersystemwhere requiredbycurrentCaliforniaBuildingCodeandCityordinance. !tt\[L/!b͸{RESPONSE:__________________________________________________________ 4.TheBuildingDivisionwillcalculateandcollecttheappropriateschooldistrictimpactfeeatthe timetheyissueabuildingpermit. !tt\[L/!b͸{RESPONSE:__________________________________________________________ 5.Priortograntingoccupancy,theBuildingDivisionwillverifythatawatermeterservingthe developmentisinplace.Therefore,itisrecommendedthatthedevelopercontacttheapplicable waterpurveyortoinquireabouttheirprocessforobtainingwaterserviceforthedevelopmentas soonaspossible.Todeterminewhothewaterpurveyorforthedevelopmentis,youmaycontact theCityofBakersfieldWaterResourcesDepartment(1000BuenaVistaRoad,Bakersfield,CA, phone:6613263715). !tt\[L/!b͸{RESPONSE:__________________________________________________________ 6.Showonthefinalbuildingplan,electricvehiclesupplyequipmenttofacilitatefutureinstallation asrequiredbytheCaliforniaGreenCode. !tt\[L/!b͸{RESPONSE:__________________________________________________________ SPR220279Page|4of11 B.DEVELOPMENTSERVICESPLANNING(1715ChesterAvenue) (Staffcontact:PatStowe6613263679orPStowe@bakersfieldcity.us) 1.Theminimumparkingrequiredforthisprojecthasbeencomputedbasedonuseandshallbeas follows: Existing(E)/SquareParkingRequired Proposed(P)UsesFootage(SF)RatioParking (E)SFRconstructedUnknownNone0space priorto1954 (P)Duplex(2units)1,049SF(each)2spaces/unit4spaces TotalRequiredParking:4spaces (Note:4parkingspacesareshownontheproposedsiteplan.Byordinance,compactandtandem spacescannotbecountedtowardsmeetingminimumparkingrequirements.Forcommercial developmentcontainingamultitenantpad,anychangeinusewhere50percentormoreofthe padrequiresadditionalparkingpursuanttoBakersfieldMunicipalSection17.58.110,thePlanning Directormayrequireparkingcommensuratewiththenewuse.) !tt\[L/!b͸{RESPONSE:__________________________________________________________ 2.Minimumparkingstalldimensionsshallbe9feetwideby18feetlongandshallbedesigned accordingtostandardsestablishedbytheTrafficEngineer.Vehiclesmayhangoverlandscape areasnomorethan21/2feetprovidedrequiredsetbacksalongstreetfrontagesaremaintained, andtreesandshrubsareprotectedfromvehicles. !tt\[L/!b͸{RESPONSE:__________________________________________________________ 3.Allparkinglots,driveways,driveaisles,loadingareas,andothervehicularaccessways,shallbe pavedwithconcrete,asphalticconcrete,orotherpavedstreetsurfacingmaterialinaccordance withtheBakersfieldMunicipalCode(Sections15.76.020and17.58.060.A.). !tt\[L/!b͸{RESPONSE:__________________________________________________________ 4.Thedevelopershallincludeafinallandscapeplanwitheachsetofthebuildingplanssubmittedto theBuildingDivision.BuildingpermitswillnotbeissueduntilthePlanningDivisionhasapproved thefinallandscapeplanforconsistencywithapprovedsiteplansandminimumordinance standards.PleaserefertothelandscapingrequirementsinChapter17.61.Landscapeplansshall include,butarenotlimitedto,dataon:gallon/boxsize,spacing,species(referenceapproved parkinglottreelist),ratioofdeciduousvs.evergreen,shadecalculations,groundcover calculations,etc. (Note1:Atthetimeafinalsiteinspectionisconducted,itisexpectedthatplantswillmatchthe speciesidentifiedandbeinstalledinthelocationsconsistentwiththeapprovedlandscapeplan. ChangesmadewithoutpriorapprovalofthePlanningstaffmayresultintheremovaland/or relocationofinstalledplantmaterialsanddelaysinobtainingbuildingoccupancy.) SPR220279Page|5of11 (Note2:NomaturelandscapingshallberemovedwithoutpriorapprovalbythePlanning Director.) a. Uponapprovalofthefinallandscapeplan,adigitalcopyshallbesubmittedtothePlanning staffcontactlistedabove.) !tt\[L/!b͸{RESPONSE:__________________________________________________________ 5.Streetaddressesfortheprojectshallbedesignatedbystaff.Thesenumberswillbetheonly addressesassignedbythecityunlessyouwishtohaveadifferentaddressprogram.Internal buildingunitaddresseswillbeonlybysuitenumberandwillbetheresponsibilityoftheowneror developertoassigntoeachtenant.PleasecontactKarlDavissonat6613263594forfurther information. (Note:Itisrecommendedthatyouassignsuitenumbersbeginningwith100,200,300etc.instead ofanalphabeticcharacter.Ifinthefutureatenantspaceweresplit,youwouldthenbeableto assignasuitenumberbetweentheexistingnumbers,whichwouldkeepyoursuitesinnumerical order.Keepinganorderlynumberingsystemwillmakeiteasierforcustomers,emergency personnel,andmaildeliverytofindthebusiness.) !tt\[L/!b͸{RESPONSE:__________________________________________________________ 6.Provideamapandalist/spreadsheetindicatingallunitnumbersthatneedtoreceivemail.All unitnumbersshallbenumeric.Mixedalphasandnumericdesignationsareunacceptableinall cases(e.g.,A1,B2,etc.).PleasecontactKarlDavissonat6613263594forfurtherinformation. !tt\[L/!b͸{RESPONSE:__________________________________________________________ 7.AParkDevelopmentandImprovementFeeshallbepaidatthetimeofthebuildingpermitbeing issuedforeachindependentresidentialunit.Wewillbasethefeeattherateineffectatthetime thepermitisissued. !tt\[L/!b͸{RESPONSE:__________________________________________________________ 8.Priortoreceivingfinalbuildingorsiteoccupancy,youmustcontactthePlanningDivision(staff contactnotedabove)forfinalinspectionandapprovalofthelandscaping,parkinglot,lightingand otherrelatedsiteimprovements.Inspectionswillnotbeconducteduntilallrequireditemshave beeninstalled.AnydeviationsfromtheapprovedplanswithoutpriorapprovalfromthePlanning Divisionmayresultinreconstructionanddelaysinobtainingabuildingorsiteoccupancy. !tt\[L/!b͸{RESPONSE:__________________________________________________________ SPR220279Page|6of11 C.FIREDEPARTMENT(2101HStreet) (StaffcontactErnieMedina;6613263682orEMedina@bakersfieldfire.us) 1.Showonthefinalbuildingplansthefollowingitems: a.Allfirehydrants,bothoffsite(nearesttosite)andonsite.Includeflowdata ƚƓğƌƌ ŷǤķƩğƓƷƭ͵Hydrantsshallbeingoodworkingconditionandaresubjecttotestingfor verification.Fireflowrequirementsmustbemetpriortoconstructioncommencingon theprojectsite.Pleaseprovidetwo(2)setsofthewaterplansstampedbyalicensed RegisteredCivilEngineertotheFireDepartmentandtwo(2)setstotheWaterResources Department(1000BuenaVistaRoad,Bakersfield,CA.93311;6613263715). i. Showdistancetothenearesthydrant. ii. Showdistancefromthenearesthydranttothefarthestpointoftheprojectsite. b.Allfiresprinklerand/orstandpipesystems,firealarmsandcommercialhoodsystems. ThesesuppressionsystemsrequirereviewandpermitsbytheFireDepartment.TheFire Departmentwillissueguidelinesforthesevariousitemsastheymayapplytothisproject. !tt\[L/!b͸{RESPONSE:__________________________________________________________ 2.Wherefireapparatusaccessroadsorawatersupplyforfireprotectionarerequiredtobe installed,suchprotectionshallbeinstalledandmadeserviceablepriortoandduringthetimeof construction. !tt\[L/!b͸{RESPONSE:__________________________________________________________ 3.Facilities,buildingsorportionsofbuildingshereafterconstructedshallbeaccessibletofire departmentapparatusbywayofan ğƦƦƩƚǝĻķŅźƩĻğƦƦğƩğƷǒƭğĭĭĻƭƭƩƚğķ withanasphalt,concrete orotherdrivingsurfaceapprovedbythefirechief.Mustbecapableofsupportingtheimposed loadoffireapparatusweighingatleast75,000poundsandshallbesurfacedwiththefirstliftof asphaltastoprovideallweatherdrivingcapabilities.Allaccess(Permanentandtemporary)to andaroundanybuildingunderconstructionmustbealeast20feetwide(26feetwidewhere buildingheightexceeds30feet),withanoverheadclearanceof13feet6inches,andcontainno obstruction.Thefireapparatusaccessroadshallextendtowithin150feetofallportionsofthe facilityandallportionsoftheexteriorwallsofthefirststoryofthebuildingasmeasuredbyan approvedroutearoundtheexteriorofthebuildingorfacility. !tt\[L/!b͸{RESPONSE:________________________________________________________ 4.AllprojectsmustcomplywiththecurrentCaliforniaFireCodeandcurrentCityofBakersfield MunicipalCode. !tt\[L/!b͸{RESPONSE:__________________________________________________________ SPR220279Page|7of11 D.WATERRESOURCES(1000BuenaVistaRoad) (StaffcontactΑTylorHester;6613263009orTHester@bakersfieldcity.us) 1.Atthistime,therearenoapplicableconditionsfortheproposedproject.Conditionsmaybe addediftheprojectchanges. E.PUBLICWORKSENGINEERING(1501TruxtunAvenue) (StaffcontactΑSusannaKormendi;6613263997orskormendi@bakersfieldcity.us) 1.Thedevelopershallconstructcurbs,gutters,crossgutters,sidewalks,andstreet/alleypaving along RobinsonStreet accordingtoadoptedcitystandards.Theseimprovementsshallbeshown onthefinalbuildingplanssubmittedtotheBuildingDivisionbeforeanybuildingpermitswillbe issued. !tt\[L/!b͸{RESPONSE:__________________________________________________________ 2.Thedevelopershallinstallnewconnection(s)tothepublicsewersystem.Thisconnectionshall beshownonthefinalbuildingplanssubmittedtotheBuildingDivisionbeforeanybuildingpermits willbeissued. !tt\[L/!b͸{RESPONSE:__________________________________________________________ 3.Showonthefinalbuildingplansallexistingconnection(s)tothepublicsewersystem. !tt\[L/!b͸{RESPONSE:__________________________________________________________ 4.Allonsiteareasrequiredtobepaved(i.e.,parkinglots,accessdrives,loadingareas,etc.)shall consistofconcrete,asphalticconcrete(TypeB.A.C.)orotherpavedstreetmaterialapprovedby theCityEngineer.Pavementshallbeaminimumthicknessof2inchesover3inchesofapproved basematerial(i.e.,ClassIIA.B.)ifconcreteisused,itshallbeaminimumthicknessof4inchesper MunicipalCodeSection17.58.060.A.Thispavingstandardshallbenotedonthefinalbuilding planssubmittedtotheBuildingDivisionbeforeanybuildingpermitswillbeissued. !tt\[L/!b͸{RESPONSE:__________________________________________________________ 5.IfagradingplanisrequiredbytheBuildingDivision,buildingpermitswillnotbeissueduntilthe gradingplanisapprovedby both thePublicWorksDepartmentandtheBuildingDivision. !tt\[L/!b͸{RESPONSE:__________________________________________________________ 6.Allstormwatergeneratedontheprojectsite,includingthestreetfrontageshallberetainedonsite unlessotherwiseallowedbythePublicWorksDepartment(pleasecontactthePublicWorks DepartmentΑSubdivisionsat6613263576). !tt\[L/!b͸{RESPONSE:__________________________________________________________ SPR220279Page|8of11 7.Priortosubmittingrevisedplans,pleasecontacttheConstructionSuperintendentat661326 3049toscheduleasiteinspectiontofindoutwhatimprovementsmayberequired.Beforeany buildingorsitecanbeoccupied,thedevelopermustreconstructorrepairsubstandardoffsite streetimprovementsthatfrontthesitetoadoptedcitystandardsasdirectedbytheCityEngineer. Additionally,anyoffsite/frontageimprovementsorrepairsrequiredduringthesiteinspection shallbeshownonthegradingplanand/or thefinalbuildingplan. !tt\[L/!b͸{RESPONSE:__________________________________________________________ 8.AstreetpermitfromthePublicWorksDepartmentshallbeobtainedbeforeanyworkcanbedone withinthepublicrightofway(streets,alleys,easements).Pleaseincludeacopyofthissiteplan reviewdecisiontothedepartmentatthetimeyouapplyforthispermit. !tt\[L/!b͸{RESPONSE:__________________________________________________________ 9.Asewerconnectionfeeshallbepaidatthetimeabuildingpermitisissued.Wewillbasethisfee attherateineffectatthetimeabuildingpermitisissued. !tt\[L/!b͸{RESPONSE:__________________________________________________________ 10.IftheprojectissubjecttotheprovisionsoftheNationalPollutantDischargeEliminationSystem (NPDES),aͻbƚƷźĭĻofLƓƷĻƓƷͼ(NOI)tocomplywiththetermsoftheGeneralPermittoDischarge StormWaterAssociatedwithConstructionActivity(SWRCBOrderNo.2009009DWQas amendedbyOrderNo.20100014DWQand20120006DWQ)mustbefiledwiththeStateWater ResourcesControlBoardinSacramentobeforethebeginningofanyconstructionactivity. CompliancewiththegeneralpermitrequiredthataStormWaterPollutionPreventionPlan (SWPPP)beprepared,continuouslycarriedout,andalwaysbeavailableforpublicinspection duringnormalconstructionhours. !tt\[L/!b͸{RESPONSE:__________________________________________________________ 11.Priortotheissuanceofeachbuildingpermit,orifnobuildingpermitisrequired,thefirstrequired Cityapprovalpriortoconstruction,thedeveloper/ownershallpayaTransportationImpactFee (TIF)forregionalfacilities.Thisfeewillbebasedontherateineffectatthetimetheapplicable approvalisissuedorinaccordancewiththeSubdivisionMapAct,asapplicable.ThePublicWorks Departmentwillcalculateanestimateofthetotalfeeuponsubmittalofconstructionplansfor theproject. !tt\[L/!b͸{RESPONSE:__________________________________________________________ 12.ThedevelopershallformanewMaintenanceDistrict.Undevelopedparcelswithinanexisting MaintenanceDistrictarerequiredtoupdateMaintenanceDistrictdocuments.Updated documents,includingProposition218BallotandCovenant,shallbesignedandnotarized.Ifthere arequestions,contactSubdivisionsat6613263588. (Note:Ifalreadywithinamaintenancedistrict,mayneedtoupdatethemaintenancedistrict form.) !tt\[L/!b͸{RESPONSE:__________________________________________________________ SPR220279Page|9of11 F.PUBLICWORKSTRAFFIC(1501TruxtunAvenue) (StaffcontactΑSusannaKormendi;6613263997orskormendi@bakersfieldcity.us) 1.Atthistime,noapplicableconditionsfortheproposedproject.Conditionsmaybeaddedifthe projectchanges. G.PUBLICWORKSSOLIDWASTE(4101TruxtunAvenue) (StaffContactRichardGutierrez:rmgutierrez@bakersfieldcity.us) 1.Youmustcontactthestaffpersonnotedabovebeforebuildingpermitscanbeissuedorwork beginsonthepropertytoestablishthelevelandtypeofservicenecessaryforthecollectionof refuseand/orrecycledmaterials.Collectionlocationsmustprovideenoughcontainmentareafor therefusethatisgeneratedwithoutviolatingrequiredzoningorsetbackrestrictions(seePlanning Divisionconditions).Levelsofservicearebasedonhowoftencollectionoccursasfollows: Cartservice1cubicyard/weekorless1timeperweek Frontloaderbinservices1cubicyard/week12cubicyards/day RolloffcompactorserviceMorethan12cubicyards/day !tt\[L/!b͸{RESPONSE:__________________________________________________________ 2.Examplesofenclosurestylescanbefoundon(Detail#ST27ST29B). !tt\[L/!b͸{RESPONSE:__________________________________________________________ 3.Residentialpropertieswithfour(4)unitsorgreaterandarerequiredtohaveADAAccessible unit/s,mustproviderefuse/recyclingenclosuresthatareADAAccessible(Detail#ST29). !tt\[L/!b͸{RESPONSE:__________________________________________________________ 4.Residentialpropertieswiththree(3)unitsorlesswillbeservicedwithautomatedcarts.Every dwellingunitmusthaveitsowncartandnomorethanthree(3)cartswillbeallowedforeach parcel.AscreenedЌ͸xВ͸concreterefusecartstoragepadmustbeprovidedforcartswhenthey arenotoutforcollection(thisareashallbeclearlyshownonthefinalbuildingplans).TheSolid WasteDivisionwilldeterminewhereservicecollectionwilloccur(streetcurbsideoralley). !tt\[L/!b͸{RESPONSE:__________________________________________________________ 5.Facilitieswithexistingrefuseservicemustimprovetheservicelocationarea(s)accordingto adoptedCitystandards(Detail#ST27andST29B).Theseimprovementsshallbeclearlyshown onthefinalbuildingplans. !tt\[L/!b͸{RESPONSE:__________________________________________________________ SPR220279Page|10of11 6.Ifutilitiesareincorporatedintotheenclosuredesign,theyshallnotinterferewithspaceprovided forrefusebinsandmustprovidesufficientprotectionmeasurestoguardtheutilitiesfrom damage. !tt\[L/!b͸{RESPONSE:__________________________________________________________ 7.Enclosuresshallnotbelocatedinanareathatwouldcauserefusetruckstointerferewith drive thrutrafficflowenteringorexitingthesite,drivethrulanes,etc. !tt\[L/!b͸{RESPONSE:__________________________________________________________ 8.Revisethesiteplantomakethetrashenclosureaccessibletotherefusetruck.Citytrucksmay notdrivedowndeadendcorridors,norbackuplongdistances;therefore,aturnaroundarea shallbeprovided. !tt\[L/!b͸{RESPONSE:__________________________________________________________ SPR220279Page|11of11