Loading...
HomeMy WebLinkAboutFMC 2022IMPACT VALVE LEAK DETECTOR MONITOR CERTIFICATION SPILL BUCKET TEST 11000 N. MoPac Expressway, Suite 500 Austin, Texas 78759 Phone: (512) 451-6334 Fax: (512) 459-1459 Date Printed and Mailed: 7/14/2022 BAKERSFIELD FIRE DEPARTMENT OFFICE OF ENVIRONMENTAL SERVICES INSPECTOR KRIS KARNS 1501 TRUXTUN AVE. BAKERSFIELD, CA 93301 Test Date: 7/13/2022 Order Number: 3457518 Dear Regulator, Enclosed are the results of recent testing performed at the following facility: PENSKE CA-094 2929 E. BRUNDAGE BAKERSFIELD, CA 93307 In an effort to keep all our record keeping and reporting requirements as current as possible, Tanknology kindly requests you notify Dawn Kohlmeyer in writing at dkohlmeyer@tanknology.com when your CUPA requires all records to be submitted electronically via the CERS database. Your assistance in this endeavor is greatly appreciated. Testing performed: Sincerely, Dawn Kohlmeyer Manager, Field Reporting LDT 5000 Field Test Apparatus Line Leak Detector Test Page 1 of 1 Work Order:3457518 Date:7/13/2022 Site Name / ID:PENSKE CA-094 / CA-094 Address:2929 E. BRUNDAGE City:BAKERSFIELD State:CA Zip:93307 Tank ID Product Product Line Tested From Existing/New Mechanical/Electronic Manufacturer/Model Serial No. Pump Operating Pressure (psi) Calibrated Leak (ml/min) Calibrated Leak (gph) Holding PSI *N/A for Electronic LD's Resiliency (ml) *N/A for Electronic LD's Metering PSI *N/A for Electronic LD's Opening Time (sec) *N/A for Electronic LD's Test Results Diesel Diesel 1 1 Existing Mechanical Red Jacket FX1DV 4741 40.00 189.0 3.00 38.00 125.00 11 7 Pass Technician Comments: Technician Name:Luis Navarro Certification #:147337 Technician Signature:Expire Date:11/29/2024 Environmental Compliance for Petroleum Systems © 2022 Tanknology Inc., Austin, TX. All rights reserved. tanknology.com Impact Valve Inspection Impact Valve Operational Inspection Work Order:3457518 Date:7/13/2022 Site Name/ID:PENSKE CA-094 Address:2929 E. BRUNDAGE City:BAKERSFIELD State:CA Zip:93307 How Inspected: Line Test NFPA 30A PEI RP1200 Other Dispenser Number Grade Secure Mount? Valve Lock?Pass/ Fail Comments 1/2 40 Pass Fail Not Tested 1 Sat/ 40 Pass Fail Not Tested 2 Sat/ 40 Pass Fail Not Tested Technician Comments: Technician Name:Luis Navarro Signature: Environmental Compliance for Petroleum Systems ©2022 Tanknology Inc., Austin, TX. All rights reserved. tanknology.com Tanknology, Inc.800-964-1250 11000 N Mopac Expy #500 Austin, Tx 78759 Luis Navarro 10117291 07/13/2022 PENSKE CA-094 2929 E. BRUNDAGE BAKERSFIELD 93307 Class A General Engineering 743160 8171123 12/31/2022 05/26/2024 07/13/2022 07/08/2024 07/13/2022 6 Veeder Root:ATG Technician (A28342) VMI:TLDT-5000 Tester (4480) OPW:EVR Phase 1 (101183) Veeder Root TLS-350 334.01 L1 DIESEL ANNULAR L2 L3 DIESEL STP SUMP L4 L5 L6 L7 DIESEL STP ANNULAR L8 L9 UDC 1 L10 L11 L12 UDC 1 ANNULAR L13 UDC 2 ANNULAR L14 UDC 3 ANNULAR L15 VENT SUMP L16 VENT SUMP ANNULAR S1 DIESEL ALL LINES S2 DEF ALL LINES 794380-301 DIESELFILL SUMP DEF ANNULAR DEF STP SUMP DIESEL FILL ANNULAR DEF STP ANNULAR UDC 2 UDC 3 794380-208 794380-208 794390-409 794380-208 794380-304 794380-304 794380-304 794380-208 794380-208 794380-208 794380-304 794380-304 794380-304 794380-208 794380-304 857280-100 857280-100 T1 Diesel T1 DieselRed Jacket FX1DV T1 Diesel T1 Diesel847390-110 07/13/2022 10117291 07/13/2022 PENSKE CA-094 2929 E. BRUNDAGE BAKERSFIELD 93307 Tanknology, Inc.800-964-1250 11000 N Mopac Expy #500 Austin, TX 78759 Luis Navarro 743160 8171123 12/31/2022 07/08/2024 PEI RP1200 / Hydrostatic OPW Spill Bucket 07/13/2022 2 OPW:EVR Phase 1 T1 Diesel OPW SWRCB, January 2006 Spill Bucket Testing Report Form This form is intended for use by contractors performing annual testing of UST spill containment structures. The completed form and printouts from tests (if applicable), should be provided to the facility owner/operator for submittal to the local regulatory agency. 1. FACILITY INFORMATION Facility Name: PENSKE CA-094 Date of Testing: 7/13/2022 Facility Address: 2929 E. BRUNDAGE , BAKERSFIELD, CA 93307 Facility Contact: Jorge Or David Phone: 661-322-3146 Date Local Agency Was Notified of Testing: 6/9/2022 Name of Local Agency Inspector (if present during testing): Bakersfield Fire 2. TESTING CONTRACTOR INFORMATION Company Name: TANKNOLOGY INC. Technician Conducting Test: Luis Navarro Credentials1: CSLB Contractor ICC Service Tech. SWRCB Tank Tester Other (Specify) License Number(s): 743160 / 8171123 3. SPILL BUCKET TESTING INFORMATION Test Method Used By: Hydrostatic Vacuum Other Test Equipment Used: LAKE TEST Equipment Resolution: 0.0625 in. Identify Spill Bucket (By Tank Number, Stored Product, etc.) Bucket Installation Type: Bucket Diameter: Bucket Depth: Wait time between applying vacuum/water and start of test Test Start Time (TI): Initial Reading (RI): Test End Time(TF): Final Reading (RF): Test Duration(TF–TI): Change in Reading (RF–RI) : Pass/Fail Threshold or Criteria: Test Result: Spill Box # Tank T1 Diesel - Fill 1 - Direct - Grade level Direct Bury Contained in Sump 12.00 16.00 15 min 09:00:00 14.00 in. H20 10:00:00 14.00 in. H20 1 hr 0.00 in. H20 +/- 0.00 Pass Spill Box # Direct Bury Contained in Sump min +/- Spill Box # Direct Bury Contained in Sump min +/- Spill Box # Direct Bury Contained in Sump min +/- Comments - (include information on repairs made prior to testing, and recommended follow-up for failed tests) CERTIFICATION OF TECHNICIAN RESPONSIBLE FOR CONDUCTING THIS TESTING I hereby certify that all the information contained in this report is true, accurate, and in full compliance with legal requirements. Technician's Signature:Date:7/13/2022 1State laws and regulations do not currently require testing to be performed by a qualified contractor. However, local requirements may be more stringent. WO: 3457518 Site Diagram (This site diagram is for reference only and is not drawn to scale) Work Order:3457518 Site ID / Name:CA-094 / PENSKE CA-094 Address:2929 E. BRUNDAGE City:BAKERSFIELD State:CA Zip:93307 W.O.# SC1-3457518 Responses Received: I10200 JUL 13, 2022 10:27 AM PENSKE 2929 E BRUNDAGE BAKERSFIELD SYSTEM CONFIGURATION SLOT BOARD TYPE POWER ON RESET CURRENT 1 4 PROBE / G.T. 164099 163861 2 INTERSTITIAL BD 202277 202235 3 INTERSTITIAL BD 202185 202259 4 2 WIRE CL 68451 68530 5 7SMARTSENSOR BD 506732 507377 6 UNUSED 9375967 9203816 7 UNUSED 9365532 9195943 8 UNUSED 9352511 9194464 9 STP SENSE BOARD 33170 33267 10 RELAY BOARD 14992 15037 11 UNUSED 9363770 9202198 12 UNUSED 9355396 9198239 13 UNUSED 9356777 9191185 14 UNUSED 9348513 9196441 15 UNUSED 9348622 9197738 16 UNUSED 9356339 9193142 COMM 1 ELEC DISP INT. 101418 101423 COMM 2 SERIAL SAT BD 484711 485801 COMM 3 UNUSED 9359539 9213598 COMM 4 UNUSED 9352568 9189865 COMM 5 RS485 SERIAL BD 68983 69067 COMM 6 RS232 SERIAL BD 14992 15037 I90200 JUL 13, 2022 10:27 AM SOFTWARE REVISION LEVEL VERSION 334.01 SOFTWARE+ACM- 346334-100-B CREATED - 17.01.09.16.10 S-MODULE+ACM- 330160-102-A SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS CSLD BIR I11100 JUL 13, 2022 10:27 AM PENSKE 2929 E BRUNDAGE BAKERSFIELD PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME L10 DISP PAN UDC 2 FUEL ALARM CLEAR 7-13-22 10:01AM L10 DISP PAN UDC 2 FUEL ALARM ALARM 7-13-22 9:52AM T 1 TANK DIESEL HIGH WATER ALARM CLEAR 7-13-22 9:50AM T 1 TANK DIESEL MAX PRODUCT ALARM CLEAR 7-13-22 9:47AM T 1 TANK DIESEL PROBE OUT CLEAR 7-13-22 9:46AM T 1 TANK DIESEL OVERFILL ALARM CLEAR 7-13-22 9:46AM T 1 TANK DIESEL PROBE OUT ALARM 7-13-22 9:46AM T 1 TANK DIESEL MAX PRODUCT ALARM ALARM 7-13-22 9:46AM T 1 TANK DIESEL OVERFILL ALARM ALARM 7-13-22 9:45AM T 1 TANK DIESEL LOW PRODUCT ALARM CLEAR 7-13-22 9:45AM T 1 TANK DIESEL HIGH WATER ALARM ALARM 7-13-22 9:44AM T 1 TANK DIESEL LOW PRODUCT ALARM ALARM 7-13-22 9:41AM L 8 ANNULAR DEF STP ANNULAR SENSOR OUT ALARM CLEAR 7-13-22 9:37AM L 7 ANNULAR DIESEL STP ANNULAR SENSOR OUT ALARM CLEAR 7-13-22 9:37AM L 6 ANNULAR DIESEL FILL ANNULAR SENSOR OUT ALARM CLEAR 7-13-22 9:37AM L 4 ANNULAR DEF ANNULAR SENSOR OUT ALARM CLEAR 7-13-22 9:37AM L 3 STP SUMP DIESEL STP SUMP SENSOR OUT ALARM CLEAR 7-13-22 9:37AM L 5 STP SUMP DEF STP SUMP SENSOR OUT ALARM CLEAR 7-13-22 9:37AM L 2 PIPE DIESEL FILL SUMP SENSOR OUT ALARM CLEAR 7-13-22 9:37AM L 1 ANNULAR DIESEL ANNULAR SENSOR OUT ALARM CLEAR 7-13-22 9:37AM L16 ANNULAR VENT SUMP ANNULAR SENSOR OUT ALARM CLEAR 7-13-22 9:37AM L10 DISP PAN UDC 2 SENSOR OUT ALARM CLEAR 7-13-22 9:37AM L15 PIPE VENT SUMP SENSOR OUT ALARM CLEAR 7-13-22 9:37AM L14 ANNULAR UDC 3 ANNULAR SENSOR OUT ALARM CLEAR 7-13-22 9:37AM L 9 DISP PAN UDC 1 SENSOR OUT ALARM CLEAR 7-13-22 9:37AM L12 ANNULAR UDC 1 ANNULAR SENSOR OUT ALARM CLEAR 7-13-22 9:37AM L13 ANNULAR UDC 2 ANNULAR SENSOR OUT ALARM CLEAR 7-13-22 9:37AM L11 DISP PAN UDC 3 SENSOR OUT ALARM CLEAR 7-13-22 9:37AM L15 PIPE VENT SUMP SENSOR OUT ALARM ALARM 7-13-22 9:37AM L16 ANNULAR VENT SUMP ANNULAR SENSOR OUT ALARM ALARM 7-13-22 9:37AM L14 ANNULAR UDC 3 ANNULAR SENSOR OUT ALARM ALARM 7-13-22 9:37AM L12 ANNULAR UDC 1 ANNULAR SENSOR OUT ALARM ALARM 7-13-22 9:37AM L13 ANNULAR UDC 2 ANNULAR SENSOR OUT ALARM ALARM 7-13-22 9:37AM L11 DISP PAN UDC 3 SENSOR OUT ALARM ALARM 7-13-22 9:37AM L10 DISP PAN UDC 2 SENSOR OUT ALARM ALARM 7-13-22 9:37AM L 9 DISP PAN UDC 1 SENSOR OUT ALARM ALARM 7-13-22 9:37AM L 8 ANNULAR DEF STP ANNULAR SENSOR OUT ALARM ALARM 7-13-22 9:37AM L 7 ANNULAR DIESEL STP ANNULAR SENSOR OUT ALARM ALARM 7-13-22 9:37AM L 6 ANNULAR DIESEL FILL ANNULAR SENSOR OUT ALARM ALARM 7-13-22 9:37AM L 3 STP SUMP DIESEL STP SUMP SENSOR OUT ALARM ALARM 7-13-22 9:37AM L 5 STP SUMP DEF STP SUMP SENSOR OUT ALARM ALARM 7-13-22 9:37AM L 4 ANNULAR DEF ANNULAR SENSOR OUT ALARM ALARM 7-13-22 9:37AM L 2 PIPE DIESEL FILL SUMP SENSOR OUT ALARM ALARM 7-13-22 9:37AM L 1 ANNULAR DIESEL ANNULAR SENSOR OUT ALARM ALARM 7-13-22 9:37AM L 4 ANNULAR DEF ANNULAR FUEL ALARM CLEAR 7-13-22 9:36AM L 4 ANNULAR DEF ANNULAR FUEL ALARM ALARM 7-13-22 9:36AM s 2 OTHER DEF ALL LINES HIGH LIQUID ALARM CLEAR 7-13-22 9:23AM s 1 OTHER DIESEL ALL LINES HIGH LIQUID ALARM CLEAR 7-13-22 9:22AM s 2 OTHER DEF ALL LINES HIGH LIQUID ALARM ALARM 7-13-22 9:22AM s 1 OTHER DIESEL ALL LINES HIGH LIQUID ALARM ALARM 7-13-22 9:21AM I11200 JUL 13, 2022 10:27 AM PENSKE 2929 E BRUNDAGE BAKERSFIELD NON-PRIORITY ALARM HISTORY ID CATEGORY DESCRIPTION ALARM TYPE STATE DATE TIME T 1 TANK DIESEL HIGH WATER WARNING CLEAR 7-13-22 9:50AM T 1 TANK DIESEL HIGH PRODUCT ALARM CLEAR 7-13-22 9:47AM T 1 TANK DIESEL HIGH PRODUCT ALARM ALARM 7-13-22 9:46AM T 1 TANK DIESEL DELIVERY NEEDED CLEAR 7-13-22 9:45AM T 1 TANK DIESEL INVALID FUEL LEVEL CLEAR 7-13-22 9:45AM T 1 TANK DIESEL HIGH WATER WARNING ALARM 7-13-22 9:44AM T 1 TANK DIESEL DELIVERY NEEDED ALARM 7-13-22 9:41AM T 1 TANK DIESEL INVALID FUEL LEVEL ALARM 7-13-22 9:41AM SYSTEM PRINTER ERROR CLEAR 6-28-22 10:27PM SYSTEM PAPER OUT CLEAR 6-28-22 10:27PM SYSTEM PRINTER ERROR ALARM 6-28-22 10:25PM SYSTEM PAPER OUT ALARM 6-28-22 10:25PM SYSTEM PRINTER ERROR CLEAR 6-23-22 9:06AM SYSTEM PAPER OUT CLEAR 6-23-22 9:06AM SYSTEM PRINTER ERROR ALARM 6-23-22 9:06AM SYSTEM PAPER OUT ALARM 6-23-22 9:06AM SYSTEM PRINTER ERROR CLEAR 5-26-22 6:21AM SYSTEM PRINTER ERROR ALARM 5-26-22 6:21AM SYSTEM PRINTER ERROR CLEAR 5-20-22 6:05AM SYSTEM PAPER OUT CLEAR 5-20-22 6:05AM SYSTEM PRINTER ERROR ALARM 5-20-22 6:05AM SYSTEM PAPER OUT ALARM 5-20-22 6:05AM SYSTEM PRINTER ERROR CLEAR 5-20-22 6:05AM SYSTEM PAPER OUT CLEAR 5-20-22 6:05AM SYSTEM PRINTER ERROR ALARM 5-20-22 6:05AM SYSTEM PAPER OUT ALARM 5-20-22 6:05AM SYSTEM PRINTER ERROR CLEAR 5-03-22 9:51AM SYSTEM PRINTER ERROR ALARM 5-03-22 9:51AM SYSTEM PRINTER ERROR CLEAR 5-03-22 9:51AM SYSTEM PAPER OUT CLEAR 5-03-22 9:51AM SYSTEM PRINTER ERROR ALARM 5-03-22 9:50AM SYSTEM PAPER OUT ALARM 5-03-22 9:50AM T 2 TANK DEF LOW TEMP WARNING CLEAR 4-11-22 11:36AM T 2 TANK DEF LOW TEMP WARNING ALARM 4-11-22 11:36AM SYSTEM PRINTER ERROR CLEAR 3-25-22 7:09AM SYSTEM PRINTER ERROR ALARM 3-25-22 7:09AM SYSTEM PRINTER ERROR CLEAR 3-18-22 6:16AM SYSTEM PAPER OUT CLEAR 3-18-22 6:16AM SYSTEM PAPER OUT ALARM 3-18-22 6:16AM SYSTEM PRINTER ERROR ALARM 3-18-22 6:16AM SYSTEM PRINTER ERROR CLEAR 3-18-22 6:16AM SYSTEM PAPER OUT CLEAR 3-18-22 6:16AM SYSTEM PRINTER ERROR ALARM 3-18-22 6:15AM SYSTEM PAPER OUT ALARM 3-18-22 6:15AM SYSTEM PRINTER ERROR CLEAR 1-29-22 5:19PM SYSTEM PAPER OUT CLEAR 1-29-22 5:19PM SYSTEM PRINTER ERROR ALARM 1-29-22 5:19PM SYSTEM PAPER OUT ALARM 1-29-22 5:19PM SYSTEM PRINTER ERROR CLEAR 1-29-22 3:09PM SYSTEM PAPER OUT CLEAR 1-29-22 3:09PM I20600 JUL 13, 2022 10:27 AM PENSKE 2929 E BRUNDAGE BAKERSFIELD TANK ALARM HISTORY TANK 1 DIESEL HIGH WATER ALARM JUL 13, 2022 9:44 AM JUL 1, 2020 10:36 AM JUL 1, 2020 10:25 AM OVERFILL ALARM JUL 13, 2022 9:45 AM SEP 22, 2021 11:07 AM JUL 14, 2021 12:23 PM LOW PRODUCT ALARM JUL 13, 2022 9:41 AM JUL 1, 2020 10:21 AM JUL 23, 2019 10:59 AM SUDDEN LOSS ALARM JUL 14, 2021 12:22 PM HIGH PRODUCT ALARM JUL 13, 2022 9:46 AM JUL 1, 2020 10:22 AM JUL 23, 2019 11:02 AM INVALID FUEL LEVEL JUL 13, 2022 9:41 AM JUL 1, 2020 10:21 AM JUL 23, 2019 11:00 AM PROBE OUT JUL 13, 2022 9:46 AM SEP 22, 2021 11:07 AM SEP 22, 2021 11:05 AM HIGH WATER WARNING JUL 13, 2022 9:44 AM JUL 14, 2021 12:10 PM JUL 1, 2020 10:36 AM DELIVERY NEEDED JUL 13, 2022 9:41 AM JUL 1, 2020 10:21 AM JUL 23, 2019 10:59 AM MAX PRODUCT ALARM JUL 13, 2022 9:46 AM JUL 1, 2020 10:22 AM JUL 23, 2019 11:02 AM LOW TEMP WARNING JUL 14, 2021 12:27 PM JUL 1, 2020 10:33 AM JUL 1, 2020 10:21 AM TANK 2 DEF OVERFILL ALARM JUL 14, 2021 12:24 PM JUL 14, 2021 12:12 PM JUL 14, 2021 12:05 PM LOW PRODUCT ALARM JUL 23, 2019 11:00 AM APR 15, 2019 3:36 PM OCT 30, 2018 9:30 AM HIGH PRODUCT ALARM JUL 14, 2021 11:39 AM JUL 1, 2020 10:05 AM JUL 23, 2019 11:03 AM INVALID FUEL LEVEL JUL 23, 2019 11:01 AM OCT 30, 2018 9:30 AM PROBE OUT APR 11, 2022 11:18 AM JUL 14, 2021 12:25 PM JUL 14, 2021 11:38 AM DELIVERY NEEDED JUL 23, 2019 11:00 AM APR 15, 2019 3:36 PM OCT 30, 2018 9:30 AM MAX PRODUCT ALARM JUL 1, 2020 10:05 AM JUL 23, 2019 11:03 AM OCT 30, 2018 9:52 AM LOW TEMP WARNING APR 11, 2022 11:36 AM JUL 23, 2019 11:14 AM TANK 5 TANK 6 TANK 7 TANK 8 TANK 9 TANK 10 TANK 11 TANK 12 TANK 13 TANK 14 TANK 15 TANK 16 I38200 JUL 13, 2022 10:28 AM I30200 JUL 13, 2022 10:28 AM PENSKE 2929 E BRUNDAGE BAKERSFIELD LIQUID ALARM HISTORY REPORT SENSOR LOCATION 1 DIESEL ANNULAR JUL 13, 2022 9:37 AM SENSOR OUT ALARM JUL 13, 2022 9:14 AM LOW LIQUID ALARM JUL 13, 2022 9:13 AM HIGH LIQUID ALARM 2 DIESEL FILL SUMP JUL 13, 2022 9:37 AM SENSOR OUT ALARM AUG 3, 2021 10:27 AM SENSOR OUT ALARM AUG 3, 2021 9:00 AM FUEL ALARM 3 DIESEL STP SUMP JUL 13, 2022 9:37 AM SENSOR OUT ALARM JUL 13, 2022 9:11 AM FUEL ALARM AUG 3, 2021 10:27 AM SENSOR OUT ALARM 4 DEF ANNULAR JUL 13, 2022 9:37 AM SENSOR OUT ALARM JUL 13, 2022 9:36 AM FUEL ALARM AUG 3, 2021 10:27 AM SENSOR OUT ALARM 5 DEF STP SUMP JUL 13, 2022 9:37 AM SENSOR OUT ALARM JUL 13, 2022 9:12 AM FUEL ALARM AUG 3, 2021 10:27 AM SENSOR OUT ALARM 6 DIESEL FILL ANNULAR JUL 13, 2022 9:37 AM SENSOR OUT ALARM JUL 13, 2022 9:10 AM FUEL ALARM AUG 3, 2021 10:27 AM SENSOR OUT ALARM 7 DIESEL STP ANNULAR JUL 13, 2022 9:37 AM SENSOR OUT ALARM JUL 13, 2022 9:11 AM FUEL ALARM AUG 3, 2021 10:27 AM SENSOR OUT ALARM 8 DEF STP ANNULAR JUL 13, 2022 9:37 AM SENSOR OUT ALARM JUL 13, 2022 9:12 AM FUEL ALARM AUG 3, 2021 10:27 AM SENSOR OUT ALARM 9 UDC 1 JUL 13, 2022 9:37 AM SENSOR OUT ALARM JUL 13, 2022 9:17 AM FUEL ALARM AUG 3, 2021 10:27 AM SENSOR OUT ALARM 10 UDC 2 JUL 13, 2022 9:52 AM FUEL ALARM JUL 13, 2022 9:37 AM SENSOR OUT ALARM JUL 13, 2022 9:16 AM FUEL ALARM 11 UDC 3 JUL 13, 2022 9:37 AM SENSOR OUT ALARM JUL 13, 2022 9:15 AM FUEL ALARM AUG 3, 2021 10:27 AM SENSOR OUT ALARM 12 UDC 1 ANNULAR JUL 13, 2022 9:37 AM SENSOR OUT ALARM JUL 13, 2022 9:17 AM FUEL ALARM NOV 22, 2021 12:10 PM FUEL ALARM 13 UDC 2 ANNULAR JUL 13, 2022 9:37 AM SENSOR OUT ALARM JUL 13, 2022 9:16 AM FUEL ALARM SEP 1, 2021 6:07 AM FUEL ALARM 14 UDC 3 ANNULAR JUL 13, 2022 9:37 AM SENSOR OUT ALARM JUL 13, 2022 9:15 AM FUEL ALARM NOV 7, 2021 6:18 AM FUEL ALARM 15 VENT SUMP JUL 13, 2022 9:37 AM SENSOR OUT ALARM JUL 13, 2022 9:14 AM FUEL ALARM AUG 3, 2021 10:27 AM SENSOR OUT ALARM 16 VENT SUMP ANNULAR JUL 13, 2022 9:37 AM SENSOR OUT ALARM JUL 13, 2022 9:14 AM FUEL ALARM DEC 26, 2021 4:01 PM FUEL ALARM I31600 JUL 13, 2022 10:28 AM PENSKE 2929 E BRUNDAGE BAKERSFIELD SMART SENSOR ALARM HISTORY REPORT SENSOR LOCATION 1 DIESEL ALL LINES JUL 13, 2022 9:21 AM HIGH LIQUID ALARM JUL 13, 2022 9:21 AM NO VACUUM ALARM AUG 3, 2021 11:08 AM VACUUM WARNING 2 DEF ALL LINES JUL 13, 2022 9:22 AM HIGH LIQUID ALARM JUL 13, 2022 9:21 AM NO VACUUM ALARM AUG 3, 2021 10:16 AM NO VACUUM ALARM 8 ATM PRESSURE I40200 JUL 13, 2022 10:28 AM I40300 JUL 13, 2022 10:28 AM I34200 JUL 13, 2022 10:28 AM I34700 JUL 13, 2022 10:28 AM IV0100 JUL 13, 2022 10:28 AM W.O.# SC1-3457518 Responses Received: 200 PENSKE 2929 E BRUNDAGE BAKERSFIELD JUL 13, 2022 10:29 AM TANK PRODUCT GALLONS INCHES WATER DEG F ULLAGE 1 DIESEL 13267 74.74 0.0 77.3 6684 2 DEF 887 31.37 87.6 1220 I90500 JUL 13, 2022 10:29 AM SOFTWARE REVISION LEVEL VERSION 334.01 SOFTWARE+ACM- 346334-100-B CREATED - 17.01.09.16.10 S-MODULE+ACM- 330160-102-A SYSTEM FEATURES: PERIODIC IN-TANK TESTS ANNUAL IN-TANK TESTS CSLD BIR I50500 JUL 13, 2022 10:29 AM SYSTEM TYPE AND LANGUAGE FLAG SYSTEM UNITS U.S. SYSTEM LANGUAGE ENGLISH SYSTEM DATE/TIME FORMAT MON DD YYYY HH:MM:SS xM I50201 JUL 13, 2022 10:29 AM SHIFT TIME 1 : DISABLED I50202 JUL 13, 2022 10:29 AM SHIFT TIME 2 : DISABLED I50203 JUL 13, 2022 10:29 AM SHIFT TIME 3 : DISABLED I50204 JUL 13, 2022 10:29 AM SHIFT TIME 4 : DISABLED I54600 JUL 13, 2022 10:29 AM TANK PER TST NEEDED WRN: DISABLED I54900 JUL 13, 2022 10:29 AM TANK ANN TST NEEDED WRN: DISABLED I55300 JUL 13, 2022 10:29 AM LINE RE-ENABLE METHOD ALARM ACKNOWLEDGE I55600 JUL 13, 2022 10:29 AM LINE PER TST NEEDED WRN: DISABLED I55900 JUL 13, 2022 10:29 AM LINE ANN TST NEEDED WRN: DISABLED I50D00 JUL 13, 2022 10:29 AM PRINT TC VOLUMES ENABLED I50E00 JUL 13, 2022 10:29 AM TEMP COMPENSATION VALUE (DEG F ): 60.0 I60B00 JUL 13, 2022 10:29 AM STICK HEIGHT OFFSET ENABLE STATUS DISABLED I51400 JUL 13, 2022 10:29 AM H-PROTOCOL DATA FORMAT HEIGHT I51A01 JUL 13, 2022 10:29 AM DAYLIGHT SAVING TIME DISABLED I51B00 JUL 13, 2022 10:29 AM I51600 JUL 13, 2022 10:29 AM RE-DIRECT LOCAL PRINTOUT DISABLED I50400 JUL 13, 2022 10:29 AM 232 SECURITY CODE PORT SECURITY CODE STATUS 1 000000 DISABLED 2 000000 DISABLED 3 000000 DISABLED 4 000000 DISABLED 5 000000 DISABLED 6 000000 DISABLED I21900 JUL 13, 2022 10:29 AM TANK CHART SECURITY DISABLED I5BD00 JUL 13, 2022 10:29 AM CUSTOM ALARM LABELS DISABLED I56000 JUL 13, 2022 10:29 AM MASS/DENSITY DISABLED I88101 JUL 13, 2022 10:29 AM PORT SETTINGS: COMM BOARD : 1 (EDIM ) RS-232 SECURITY CODE : DISABLED I88102 JUL 13, 2022 10:29 AM PORT SETTINGS: COMM BOARD : 2 (S-SAT ) BAUD RATE : 9600 PARITY : NONE STOP BIT : 1 STOP DATA LENGTH: 8 DATA RS-232 SECURITY CODE : DISABLED DTR NORMAL STATE: HIGH I88103 JUL 13, 2022 10:29 AM I88104 JUL 13, 2022 10:29 AM I88105 JUL 13, 2022 10:29 AM PORT SETTINGS: COMM BOARD : 5 (RS-485) BAUD RATE : 2400 PARITY : EVEN STOP BIT : 1 STOP DATA LENGTH: 7 DATA RS-232 SECURITY CODE : DISABLED I88106 JUL 13, 2022 10:29 AM PORT SETTINGS: COMM BOARD : 6 (RS-232) BAUD RATE : 9600 PARITY : ODD STOP BIT : 1 STOP DATA LENGTH: 7 DATA RS-232 SECURITY CODE : DISABLED I52000 JUL 13, 2022 10:29 AM RECEIVER AUTO DIAL TYPE +ACY- START TIME RCVR LOCATION LABEL DIAL TYPE START TIME 1 ON DATE ??? 13, 2022 DISABLED 2 ON DATE ??? 13, 2022 DISABLED 3 ON DATE ??? 13, 2022 DISABLED 4 ON DATE ??? 13, 2022 DISABLED 5 ON DATE ??? 13, 2022 DISABLED 6 ON DATE ??? 13, 2022 DISABLED 7 ON DATE ??? 13, 2022 DISABLED 8 ON DATE ??? 13, 2022 DISABLED I60100 JUL 13, 2022 10:29 AM TANK CONFIGURATION DEVICE LABEL CONFIGURED 1 DIESEL ON 2 DEF ON 3 OFF 4 OFF I60200 JUL 13, 2022 10:29 AM TANK PRODUCT LABEL TANK PRODUCT LABEL 1 DIESEL 2 DEF 3 4 I60300 JUL 13, 2022 10:29 AM TANK PRODUCT CODE TANK PRODUCT LABEL 1 DIESEL 1 2 DEF 2 3 3 4 4 I60900 JUL 13, 2022 10:29 AM TANK THERMAL COEFFICIENT TANK PRODUCT LABEL 1 DIESEL 0.000450 2 DEF 0.000400 3 0.000000 4 0.000000 I60700 JUL 13, 2022 10:29 AM TANK DIAMETER TANK PRODUCT LABEL INCHES 1 DIESEL 119.00 2 DEF 72.00 3 0.00 4 0.00 I60A00 JUL 13, 2022 10:29 AM TANK FULL VOLUME TANK PRODUCT LABEL TANK PROFILE GALLONS 1 DIESEL 4 PTS 19951 2 DEF 4 PTS 2107 3 1 PT 0 4 1 PT 0 I60400 JUL 13, 2022 10:29 AM TANK FULL VOLUME TANK PRODUCT LABEL GALLONS 1 DIESEL 19951 2 DEF 2107 3 0 4 0 I60500 JUL 13, 2022 10:29 AM TANK 4 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 DIESEL 19951 16170 9935 3712 2 DEF 2107 1719 1066 408 3 0 0 0 0 4 0 0 0 0 I60600 JUL 13, 2022 10:29 AM TANK 20 POINT VOLUMES TANK PRODUCT LABEL GALLONS 1 DIESEL 19951 0 0 0 0 16170 0 0 0 0 9935 0 0 0 0 3712 0 0 0 0 2 DEF 2107 0 0 0 0 1719 0 0 0 0 1066 0 0 0 0 408 0 0 0 0 3 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 I61500 JUL 13, 2022 10:29 AM TANK PRODUCT LABEL METER DATA 1 DIESEL NO 2 DEF NO 3 NO 4 NO I62F00 JUL 13, 2022 10:29 AM MAG PROBE FLOAT SIZE TANK PRODUCT LABEL FLOAT SIZE: 1 DIESEL 4.0 IN. 2 DEF 2.0 IN. I62700 JUL 13, 2022 10:29 AM TANK HIGH WATER WARNING LIMIT TANK PRODUCT LABEL INCHES 1 DIESEL 1.0 I64200 JUL 13, 2022 10:29 AM WATER ALARM FILTER TANK PRODUCT LABEL 1 DIESEL OFF I62400 JUL 13, 2022 10:29 AM TANK HIGH WATER LEVEL LIMIT TANK PRODUCT LABEL INCHES 1 DIESEL 2.0 I62800 JUL 13, 2022 10:29 AM TANK MAXIMUM VOLUME LIMIT TANK PRODUCT LABEL GALLONS 1 DIESEL 19951 2 DEF 2107 3 0 4 0 I62300 JUL 13, 2022 10:29 AM TANK OVERFILL LEVEL LIMIT TANK PRODUCT LABEL GALLONS 1 DIESEL 17956 2 DEF 1896 3 0 4 0 I62200 JUL 13, 2022 10:29 AM TANK HIGH PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 DIESEL 18953 2 DEF 2002 3 0 4 0 I62900 JUL 13, 2022 10:29 AM TANK DELIVERY REQUIRED LIMIT TANK PRODUCT LABEL GALLONS 1 DIESEL 1995 2 DEF 211 3 0 4 0 I62100 JUL 13, 2022 10:29 AM TANK LOW PRODUCT LIMIT TANK PRODUCT LABEL GALLONS 1 DIESEL 2000 2 DEF 200 3 0 4 0 I62600 JUL 13, 2022 10:29 AM TANK LEAK ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 DIESEL 99 2 DEF 99 3 99 4 99 I62500 JUL 13, 2022 10:29 AM TANK SUDDEN LOSS LIMIT TANK PRODUCT LABEL GALLONS 1 DIESEL 99 2 DEF 99 3 99 4 99 I60800 JUL 13, 2022 10:29 AM TANK TILT TANK PRODUCT LABEL INCHES 1 DIESEL 0.00 2 DEF 0.00 3 0.00 4 0.00 I60B00 JUL 13, 2022 10:29 AM STICK HEIGHT OFFSET ENABLE STATUS DISABLED I60C00 JUL 13, 2022 10:29 AM TANK STICK HEIGHT OFFSET TANK PRODUCT LABEL INCHES 1 DIESEL 0.00 2 DEF 0.00 3 0.00 4 0.00 I61200 JUL 13, 2022 10:29 AM TANK MANIFOLDED PARTNERS TANK PRODUCT LABEL SIPHON MANIFOLDED TANKS LINE MANIFOLDED TANKS 1 DIESEL NONE NONE 2 DEF NONE NONE 3 NONE NONE 4 NONE NONE I63600 JUL 13, 2022 10:29 AM PERIODIC LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 DIESEL 0 2 DEF 0 3 0 4 0 I62A00 JUL 13, 2022 10:30 AM ANNUAL LEAK TEST MIN VOLUME TANK PRODUCT LABEL GALLONS 1 DIESEL 0 2 DEF 0 3 0 4 0 I62C00 JUL 13, 2022 10:30 AM TANK PERIODIC TEST TYPE TANK PRODUCT LABEL PERIODIC TEST TYPE 1 DIESEL STANDARD 2 DEF STANDARD 3 STANDARD 4 STANDARD I62D00 JUL 13, 2022 10:30 AM TANK LEAK TEST FAIL ALARMS TANK PRODUCT LABEL 1 DIESEL GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 2 DEF GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 3 GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED 4 GROSS TEST FAIL ALARM DISABLED PERIODIC TEST FAIL ALARM DISABLED ANNUAL TEST FAIL ALARM DISABLED I63100 JUL 13, 2022 10:30 AM TANK LEAK TEST AVERAGING TANK PRODUCT LABEL ANNUAL PERIODIC 1 DIESEL OFF OFF 2 DEF OFF OFF 3 OFF OFF 4 OFF OFF I63000 JUL 13, 2022 10:30 AM IN-TANK LEAK TEST NOTIFY TANK PRODUCT LABEL TANK TEST NOTIFY: 1 DIESEL OFF 2 DEF OFF 3 OFF 4 OFF I63200 JUL 13, 2022 10:30 AM TANK TEST SIPHON BREAK TANK PRODUCT LABEL SIPHON BREAK 1 DIESEL OFF 2 DEF OFF 3 OFF 4 OFF I61000 JUL 13, 2022 10:30 AM TANK DELIVERY DELAY TANK PRODUCT LABEL 1 DIESEL 1 2 DEF 1 3 1 4 1 I63A00 JUL 13, 2022 10:30 AM LOW LEVEL PUMP THRESHOLD FOR SEQUENTIAL LINE MANIFOLD TANK PRODUCT LABEL PUMP THRESHOLD 1 DIESEL 10.00+ACU- 2 DEF 10.00+ACU- 3 10.00+ACU- 4 10.00+ACU- I61100 JUL 13, 2022 10:30 AM LEAK TEST METHOD - - - - - - - - - - - - TEST ON DATE : ALL TANK JAN 9, 2017 START TIME : DISABLED TEST RATE :0.20 GAL/HR DURATION : 2 HOURS TST EARLY STOP:DISABLED I61300 JUL 13, 2022 10:30 AM CSLD PROBABLITY OF DETECTION I61400 JUL 13, 2022 10:30 AM CSLD CLIMATE FACTOR I61600 JUL 13, 2022 10:30 AM TANK PRODUCT LABEL CAL UPDATE 1 DIESEL IMMEDIATE 2 DEF IMMEDIATE 3 IMMEDIATE 4 IMMEDIATE I61A00 JUL 13, 2022 10:30 AM IN-TANK LEAK TEST EARLY STOP TANK PRODUCT LABEL TST EARLY STOP: 1 DIESEL DISABLED 2 DEF DISABLED 3 DISABLED 4 DISABLED I61B00 JUL 13, 2022 10:30 AM IN-TANK LEAK GROSS TEST AUTO-CONFIRM I61C00 JUL 13, 2022 10:30 AM CSLD REPORT ONLY I62B00 JUL 13, 2022 10:30 AM TANK LAST ANNUAL TEST TANK PRODUCT LABEL DATE 1 DIESEL ??? 0, 0 2 DEF ??? 0, 0 3 ??? 0, 0 4 ??? 0, 0 I63300 JUL 13, 2022 10:30 AM LEAK TEST REPORT FORMAT: NORMAL I63400 JUL 13, 2022 10:30 AM RECONCILIATION WARNING LIMIT TANK PRODUCT LABEL GALLONS 1 DIESEL 0 2 DEF 0 3 0 4 0 I63500 JUL 13, 2022 10:30 AM RECONCILIATION ALARM LIMIT TANK PRODUCT LABEL GALLONS 1 DIESEL 1 2 DEF 1 3 1 4 1 I63900 JUL 13, 2022 10:30 AM ACCU CHART END SHAPE FACTOR TANK PRODUCT LABEL 1 DIESEL END FACTOR: NONE 2 DEF END FACTOR: NONE 3 END FACTOR: NONE 4 END FACTOR: NONE I78000 JUL 13, 2022 10:30 AM I77700 JUL 13, 2022 10:30 AM I77800 JUL 13, 2022 10:30 AM I78C00 JUL 13, 2022 10:30 AM I78300 JUL 13, 2022 10:30 AM I78F00 JUL 13, 2022 10:30 AM I78700 JUL 13, 2022 10:30 AM I70200 JUL 13, 2022 10:30 AM LIQUID LABEL DEVICE LABEL 1 DIESEL ANNULAR 2 DIESEL FILL SUMP 3 DIESEL STP SUMP 4 DEF ANNULAR 5 DEF STP SUMP 6 DIESEL FILL ANNULAR 7 DIESEL STP ANNULAR 8 DEF STP ANNULAR 9 UDC 1 10 UDC 2 11 UDC 3 12 UDC 1 ANNULAR 13 UDC 2 ANNULAR 14 UDC 3 ANNULAR 15 VENT SUMP 16 VENT SUMP ANNULAR I70300 JUL 13, 2022 10:30 AM LIQUID TYPE SENSOR LOCATION TYPE 1 DIESEL ANNULAR DUAL POINT HYDROSTATIC 2 DIESEL FILL SUMP TRI-STATE (SINGLE FLOAT) 3 DIESEL STP SUMP TRI-STATE (SINGLE FLOAT) 4 DEF ANNULAR TRI-STATE (SINGLE FLOAT) 5 DEF STP SUMP TRI-STATE (SINGLE FLOAT) 6 DIESEL FILL ANNULAR TRI-STATE (SINGLE FLOAT) 7 DIESEL STP ANNULAR TRI-STATE (SINGLE FLOAT) 8 DEF STP ANNULAR TRI-STATE (SINGLE FLOAT) 9 UDC 1 TRI-STATE (SINGLE FLOAT) 10 UDC 2 TRI-STATE (SINGLE FLOAT) 11 UDC 3 TRI-STATE (SINGLE FLOAT) 12 UDC 1 ANNULAR TRI-STATE (SINGLE FLOAT) 13 UDC 2 ANNULAR TRI-STATE (SINGLE FLOAT) 14 UDC 3 ANNULAR TRI-STATE (SINGLE FLOAT) 15 VENT SUMP TRI-STATE (SINGLE FLOAT) 16 VENT SUMP ANNULAR TRI-STATE (SINGLE FLOAT) I70400 JUL 13, 2022 10:30 AM LIQUID CATEGORY SENSOR LOCATION CATEGORY 1 DIESEL ANNULAR ANNULAR SPACE 2 DIESEL FILL SUMP PIPING SUMP 3 DIESEL STP SUMP STP SUMP 4 DEF ANNULAR ANNULAR SPACE 5 DEF STP SUMP STP SUMP 6 DIESEL FILL ANNULAR ANNULAR SPACE 7 DIESEL STP ANNULAR ANNULAR SPACE 8 DEF STP ANNULAR ANNULAR SPACE 9 UDC 1 DISPENSER PAN 10 UDC 2 DISPENSER PAN 11 UDC 3 DISPENSER PAN 12 UDC 1 ANNULAR ANNULAR SPACE 13 UDC 2 ANNULAR ANNULAR SPACE 14 UDC 3 ANNULAR ANNULAR SPACE 15 VENT SUMP PIPING SUMP 16 VENT SUMP ANNULAR ANNULAR SPACE I74200 JUL 13, 2022 10:30 AM 2 WIRE CL LABEL DEVICE LABEL 1 2 3 4 5 6 7 8 I74300 JUL 13, 2022 10:30 AM 2 WIRE CL TYPE SENSOR LOCATION TYPE 1 DISCRIM. INTERSTITIAL 2 DISCRIM. INTERSTITIAL 3 DISCRIM. INTERSTITIAL 4 DISCRIM. INTERSTITIAL 5 DISCRIM. INTERSTITIAL 6 DISCRIM. INTERSTITIAL 7 DISCRIM. INTERSTITIAL 8 DISCRIM. INTERSTITIAL I74400 JUL 13, 2022 10:30 AM 2 WIRE CL CATEGORY SENSOR LOCATION CATEGORY 1 OTHER SENSORS 2 OTHER SENSORS 3 OTHER SENSORS 4 OTHER SENSORS 5 OTHER SENSORS 6 OTHER SENSORS 7 OTHER SENSORS 8 OTHER SENSORS I74700 JUL 13, 2022 10:30 AM I74800 JUL 13, 2022 10:30 AM I74900 JUL 13, 2022 10:30 AM I7BC00 JUL 13, 2022 10:30 AM I80200 JUL 13, 2022 10:30 AM I80300 JUL 13, 2022 10:30 AM I80400 JUL 13, 2022 10:30 AM I80700 JUL 13, 2022 10:30 AM RELAY LABEL DEVICE LABEL 1 DEF SHUTDOWN 2 DIESEL SHUTDOWN 3 4 OVERFILL ALARM I80900 JUL 13, 2022 10:30 AM RELAY ORIENTATION RELAY DESIGNATION ORIENTATION 1 DEF SHUTDOWN NORMALLY CLOSED 2 DIESEL SHUTDOWN NORMALLY OPEN 3 NORMALLY OPEN 4 OVERFILL ALARM NORMALLY OPEN I80B00 JUL 13, 2022 10:30 AM RELAY TANK ASSIGNMENT RELAY DESIGNATION TANK 1 DEF SHUTDOWN NONE 2 DIESEL SHUTDOWN 1 3 NONE 4 OVERFILL ALARM NONE I80A00 JUL 13, 2022 10:30 AM RELAY TYPE RELAY DESIGNATION TYPE 1 DEF SHUTDOWN STANDARD 2 DIESEL SHUTDOWN PUMP CONTROL OUTPUT 3 STANDARD 4 OVERFILL ALARM STANDARD I80C00 JUL 13, 2022 10:30 AM I80800 JUL 13, 2022 10:30 AM RELAY SETUP REPORT R 1:DEF SHUTDOWN TYPE: STANDARD NORMALLY CLOSED - NO ALARM ASSIGNMENTS - R 2:DIESEL SHUTDOWN TYPE: PUMP CONTROL OUTPUT TANK +ACM-: 1 IN-TANK ALARMS T 1:HIGH WATER ALARM LIQUID SENSOR ALMS L 3:FUEL ALARM L 9:FUEL ALARM L10:FUEL ALARM L11:FUEL ALARM L 3:SENSOR OUT ALARM L 9:SENSOR OUT ALARM L10:SENSOR OUT ALARM L11:SENSOR OUT ALARM L 3:SHORT ALARM L 9:SHORT ALARM L10:SHORT ALARM L11:SHORT ALARM R 3: TYPE: STANDARD NORMALLY OPEN - NO ALARM ASSIGNMENTS - R 4:OVERFILL ALARM TYPE: STANDARD NORMALLY OPEN IN-TANK ALARMS ALL:OVERFILL ALARM ALL:HIGH PRODUCT ALARM ALL:MAX PRODUCT ALARM I79000 JUL 13, 2022 10:30 AM EDIM:1 VR:349858-003-B TD:16.08.22.07.40 I79100 JUL 13, 2022 10:30 AM I72300 JUL 13, 2022 10:30 AM PENSKE 2929 E BRUNDAGE BAKERSFIELD SMARTSENSOR ASSIGNMENT DEVICE LABEL CATEGORY 01 DIESEL ALL LINES VAC SENSOR 02 DEF ALL LINES VAC SENSOR 03 UNKNOWN 04 UNKNOWN 05 UNKNOWN 06 UNKNOWN 07 UNKNOWN 08 ATM PRESSURE ATM P SENSOR 09 UNKNOWN 10 UNKNOWN 11 UNKNOWN 12 UNKNOWN 13 UNKNOWN 14 UNKNOWN 15 UNKNOWN 16 UNKNOWN 17 UNKNOWN 18 UNKNOWN 19 UNKNOWN 20 UNKNOWN 21 UNKNOWN 22 UNKNOWN 23 UNKNOWN 24 UNKNOWN 25 UNKNOWN 26 UNKNOWN 27 UNKNOWN 28 UNKNOWN 29 UNKNOWN 30 UNKNOWN 31 UNKNOWN 32 UNKNOWN 33 UNKNOWN 34 UNKNOWN 35 UNKNOWN 36 UNKNOWN 37 UNKNOWN 38 UNKNOWN 39 UNKNOWN 40 UNKNOWN I72A00 JUL 13, 2022 10:30 AM VACUUM SENSOR VOLUME DEVICE LABEL VOLUME 1 DIESEL ALL LINES 43.0 GALLONS 2 DEF ALL LINES 36.0 GALLONS IV4E00 JUL 13, 2022 10:30 AM IV4F00 JUL 13, 2022 10:30 AM IV4000 JUL 13, 2022 10:30 AM PENSKE 2929 E BRUNDAGE BAKERSFIELD VAPOR PROCESSOR TYPE NONE IV4700 JUL 13, 2022 10:30 AM PENSKE 2929 E BRUNDAGE BAKERSFIELD ASSESSMENT TIME START TIME: 11:59 PM TIME DELAY MINUTES: 1 IV5200 JUL 13, 2022 10:30 AM IV4A00 JUL 13, 2022 10:30 AM IV4B00 JUL 13, 2022 10:30 AM IV4900 JUL 13, 2022 10:30 AM IV1000 JUL 13, 2022 10:30 AM ISD VERSION: 01.05 Test Duration Test Pressure P/F Threshold Tank Annular - Vacuum 1 hr, 20k or less tank 10" hg 0 loss, int dry before and after test Tank Annular - Vacuum 2 hr, >20k tank 10" hg 0 loss, int dry before and after test Line Annular - Pressure 1 hr 5 psi 0 loss STP Sump - Hydro 1 hr 4" above highest penetration or sidewall seam less than 1/8" over hour, settle time of 15 minutes minimum prior to starting the test UDC Sump - Hydro 1 hr 4" above highest penetration or sidewall seam less than 1/8" over hour, settle time of 15 minutes minimum prior to starting the test Spill Bucket - SW Vac 1 min 30" wc no greater than 4" wc vaccum decay - bucket must be dry Spill Bucket - SW Hydro 1 hr within 1.5" of top of the bucket less than 1/8" over hour, settle time of 5 minutest minimum prior to starting the test Spill Bucket - DW Vac 1 min 15" wc no greater than 3" wc vaccum decay - int must be dry