Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
1300 Easton Drive (2)
SENTVIAUSMAILANDELECTRONICMAIL July28,2022 Applicant StevenL.KiekeArchitect Attn:SteveKieke 211624thStreet,Suite2 Bakersfield,CA93301 PropertyOwner FairwayColimaCASevenLLC Attn:JoshuaLiang 21700CopleyDrive,Suite320 DiamondBar,CA91765 RE:NoticeofDecisionSitePlanReview(ProjectNo.220076)(Ward2) DearMr.Kieke: Theplansforconstructionofa2,350squarefootdrivethrurestaurantinC2(RegionalCommercialZone)district locatedat1300EastonDrivehavebeenreviewedbytheSitePlanReviewCommitteeanditemsrequiringyourattention areattached. Oncethecorrectionsnotedintheattachedsiteplancompliancelisthavebeenmade,theproposalwillmeetthe minimumrequiredcodes,policiesandstandardsfordevelopmentasadoptedbytheBakersfieldCityCouncil.Specific itemshavebeenidentified(seeattachedSitePlanComplianceList)thatyouneedtoresolvebeforeyoucanobtaina buildingpermitorbeallowedoccupancy.Theseitemsmayincludechangesoradditionsthatneedtobeshownonthe finalbuildingplans,alertyoutospecificfees,and/orarecommentsthatwillhelpyouincomplyingwiththeĭźƷǤƭ developmentstandards.Eachitemwillnotewhenitistobecompletedandtheyhavebeengroupedbydepartment sothatyouknowwhomtocontactifyouhavequestions. Yournextstepistoeitherapplyfornecessarybuildingpermitstoconstructyourproject,orbeginyourbusiness BuildingDivision.TheSite activitiesdependingontherequestsubmitted.Youmustsubmitfinalbuildingplanstothe PlanReviewCommitteewillreviewthesefinalplanswhilebuildingplancheckoccurstoensurethatyousatisfythe itemsintheSitePlanComplianceList.Pleasereadthemcarefully.Failuretosatisfyanitemmaydelayyourobtaining abuildingpermitorcommencingyourproject. AfterconstructionofyourprojectbutbeforetheCitycanallowoccupancy,theBuildingDivisionmustinspectthe developmenttofindifitcomplieswiththeapprovedplans,andanyotherrelevantpermitsandcodes.Ifyouhave satisfiedalloftherequirements,theBuildingDirectorwillissueacertificateofoccupancy;ifnot,theareainspectorwill giveyouacorrectionnotice.Onceyouhavemadeallofthecorrections,theBuildingDirectorcanissueacertificateof occupancy.YoumaynotoccupyadevelopmentuntiltheBuildingDirectorhasissuedacertificateofoccupancy. INDEMNIFICATIONCONDITION InconsiderationbytheCityofBakersfieldforlanduseentitlements,includingbutnotlimitedtorelated environmentalapprovalsrelatedtoorarisingfromthisproject,theapplicant,and/orpropertyownerand/or subdividerΛͻ!ƦƦƌźĭğƓƷͼherein)agreestoindemnify,defend,andholdharmlesstheCityofBakersfield,itsofficers, agents,employees,departments,commissionersandboardsΛͻ/źƷǤͼherein)againstanyandallliability,claims, actions,causesofactionsordemandswhatsoeveragainstthem,oranyofthem,beforeadministrativeorjudicial tribunalsofanykindwhatsoever,inanywayarisingfrom,thetermsandprovisionsofthisapplication,including withoutlimitationanyCEQAapprovaloranyrelateddevelopmentapprovalsorconditionswhetherimposedby theCity,ornot,exceptfor/źƷǤƭsoleactivenegligenceorwillfulmisconduct. ThisindemnificationconditiondoesnotpreventtheApplicantfromchallenginganydecisionbytheCityrelatedto thisprojectandtheobligationsofthisconditionapplyregardlessofwhetheranyotherpermitsorentitlements areissued. TheCitywillpromptlynotifyApplicantofanysuchclaim,action,orproceeding,failingunderthisconditionwithin thirty(30)daysofactuallyreceivingsuchclaim.TheCity,initssolediscretion,shallbeallowedtochoosethe attorneyoroutsidelawfirmtodefendtheCityatthesolecostandexpenseoftheApplicantandtheCityisnot obligatedtouseanylawfirmorattorneychosenbyanotherentityorparty. REVISIONSTOTHEAPPROVEDPLAN Anytimeaftersiteplanapprovalbutbeforetheapprovalexpires,youmaysubmitrevisionstotheplan.Wewilltreat theserevisionsasanewsiteplanapplicationsubjecttoanewreviewandrequiredfees.ThePlanningDirectorcanonly approveminorchangestotheoriginalplanwithoutanewapplicationiftheyarenecessarytomeetacondition, mitigation,orresultfromphysicalobstaclesorothercomparableconstraints(SeeSection17.08.080.c.3oftheZoning Ordinance). EXPIRATIONOFPLANS Thissiteplanexpireson July29,2024(2yearsfromthedecisiondate),unlessbuildingpermitshavebeenissued,or wheretheusehascommencedonprojectsnotrequiringabuildingpermit.Theprojectmustbecompletedwithin5 yearsfromthedecisiondate.Ifthepropertyisrezoned,siteplanapprovalwillexpireupontheeffectivedateforthe rezoningunlesstheuseispermittedinthenewzone. ThePlanningDirectormayextendtheexpirationdateuptoone(1)yearifyouresubmitnewplansforcheckagainst thecoderequirementsineffectatthattimeandincludeawrittenrequestfortheextension.Wemustreceivethis request before expirationoftheprojectapproval.Wewillnotrequireafeeforthisextensionrequest;however, changestotheplansoriginallyapprovedforpurposesotherthancoderequirementsshallbesubjecttoanewsiteplan review,includingpaymentofallrequiredfees(SeeSection17.08.080.DoftheZoningOrdinance). ENVIRONMENTALDETERMINATION ThissiteplanreviewhasbeenfoundtobeexemptfromtheprovisionsoftheCaliforniaEnvironmentalQualityAct (CEQA)accordingtoSection15332.Thisprojectisexemptbecauseitisaninfilldevelopmentthatisconsistentwiththe generalplanandzoningregulations,iswithinanareapredominantlydevelopedwithurbanuses,isnotidentifiedas willnotsignificantlyaffecttrafficnoise,airorwaterquality,and criticalhabitatforendangeredorthreatenedspecies, willbeadequatelyservedbyappropriateutilitiesandpublicservices.ANoticeofExemptionhasbeenpreparedandis availableforreviewatthePlanningDivision. SPR220076Page|2of13 APPEAL Anypersonmayappealthisdecision.Anappealislimitedtowhetherornotanadopteddevelopmentstandard, zoningregulation,mitigation,orpolicyappliedornotappliedtotheproject,wasdoneconsistentwiththe authoritygrantedbycityordinancesortheCaliforniaEnvironmentalQualityAct(CEQA).Theappealmustbein ingtheprecisebasisorissueasnoted,mustincludetheappropriatefilingfee,andmustbefiledwithin writingstat 10days ofthedecisiondatetotheCityofBakersfieldPlanningCommission(c/oBakersfieldPlanningDirector, 1715ChesterAvenue,Bakersfield,CA93301).ThePlanningCommissionwillholdapublichearingontheappeal andtheirdecisionwillbefinalunlesstheirdecisionisappealedtotheCityCouncil. Siteplanapprovalisbasedonthestatementsmadeintheapplicationandtheplansyousubmitted.Anyerrorsor omissionsontheseplanscouldalterthecompliancelistand/orvoidthisdecision.Ifyouhavequestionsabout anyoftheitemsnotedintheSitePlanComplianceList,youmustspeaktothecontactpersonrepresentingthe departmentrequiringthatitem. Correspondencewillcontinuetobesenttotheapplicantonrecord.Shouldtheapplicantchange,itistheproperty ƚǞƓĻƩƭresponsibilitytoupdatethecontactinformationwiththePlanningDivision.Ifyouhaveotherquestions regardinggeneralinformationaboutthesiteplanreviewprocess,pleasecontactthePlanningDivisionat(661) 3263733. DECISIONDATE:July28,2022 Sincerely, LindaMitchell PrincipalPlanner 9ƓĭƌƚƭǒƩĻ cc:AllInterestedAgenciesΑForyourrecords. S:\\CounterOperations\\01_SPR\\2022\\220076_1300EastonDr_2756Sfdrivethrurestaurantpad\\_sprltr_.docx SPR220076Page|3of13 CONDITIONSANDORDINANCECOMPLIANCE Thefollowingarespecificitemsthatyouneedtoresolvebeforeyoucanobtainabuildingpermitorbeallowed occupancy.Theseitemsincludeconditionsand/ormitigationrequiredbyprevioussiteentitlementapprovals (thesewillbespecificallynoted),changesoradditionsthatneedtobeshownonthefinalbuildingplans,alert youtospecificfees,andotherconditionsforyourprojecttosatisfythe/źƷǤƭdevelopmentstandards. Theitemslistedbelowwillusuallyneedtobeshownonthefinalbuildingplansorcompletedbeforeabuilding permitisissued.Aspartofthebuildingpermitsubmittal,identifythelocationofyourresponsebyusingthe !tt\[L/!b{RESPONSE lineprovideddirectlybelowtheitem(example:sheetnumber,detail,etc.). A.DEVELOPMENTSERVICESBUILDING(1715ChesterAvenue) (StaffcontactOscarFuentes;6613263676orOFuentes@bakersfieldcity.us) 1.Showonthefinalbuildingplanpedestrianaccessfromthepublicwayandaccessibleparking. Privatestreetsarenotthepublicway. !tt\[L/!b{RESPONSE:__________________________________________________________ 2.Thedevelopershallincludefireresistivewallconstructiondetailswiththefinalbuildingplansfor allexteriorwallsofanybuildingthatiswithinthedistanceassetforthinTable602oftheCalifornia BuildingCode. !tt\[L/!b{RESPONSE:__________________________________________________________ 3.Includewithorshowonthefinalbuildingplansinformationnecessarytoverifythattheproject complieswithallaccessibilityrequirementsofTitle24oftheCaliforniaBuildingCode. !tt\[L/!b{RESPONSE:__________________________________________________________ 4.ThedevelopershallobtainallrequiredapprovalsfromtheKernCountyEnvironmentalHealth ServicesDepartment(2700ͻaͼStreet,Bakersfield,CA.,93301;PH6618628700)foranyfood handlingfacility(i.e.,market,delicatessen,café,concession,restaurant)beforebuildingpermits canbeissued. !tt\[L/!b{RESPONSE:__________________________________________________________ 5.Buildingsorstructuresshallrequireinstallationofanautomaticfiresprinklersystemwhere requiredbycurrentCaliforniaBuildingCodeandCityordinance. !tt\[L/!b{RESPONSE:__________________________________________________________ 6.TheBuildingDivisionwillcalculateandcollecttheappropriateschooldistrictimpactfeeatthe timetheyissueabuildingpermit. !tt\[L/!b{RESPONSE:__________________________________________________________ SPR220076Page|4of13 7.FinalBuildingplansshallshowpedestrianaccesspathwaysoreasementsforpersonswith disabilitiesfrompublicrightsofwaysthatconnecttoallaccessiblebuildings,facilities,elements, andspacesinaccordancewiththeCaliforniaBuildingCode.Thesepedestrianaccesswaysshall notbeparalleltovehicularlanesunlessseparatedby curbsorrailings. !tt\[L/!b{RESPONSE:__________________________________________________________ 8.Priortograntingoccupancy,theBuildingDivisionwillverifythatawatermeterservingthe developmentisinplace.Therefore,itisrecommendedthatthedevelopercontacttheapplicable waterpurveyortoinquireabouttheirprocessforobtainingwaterserviceforthedevelopmentas soonaspossible.Todeterminewhothewaterpurveyorforthedevelopmentis,youmaycontact theCityofBakersfieldWaterResourcesDepartment(1000BuenaVistaRoad,Bakersfield,CA, phone:6613263715). !tt\[L/!b{RESPONSE:__________________________________________________________ 9.Showonthefinalbuildingplan,electricvehiclesupplyequipmenttofacilitatefutureinstallation asrequiredbytheCaliforniaGreenCode. !tt\[L/!b{RESPONSE:__________________________________________________________ B.DEVELOPMENTSERVICESPLANNING(1715ChesterAvenue) (Staffcontact:RyderDilley6613263616orRDilley@bakersfieldcity.us) 1.Theminimumparkingrequiredforthisprojecthasbeencomputedbasedonuseandshallbeas follows: No.of Required Existing/ProposedUseArea/UnitParkingRatioParkingSpaces ExistingMotel107units1space/unit107spaces Restaurant2,350sq.ft.1space/75sq.ft.31spaces DriveThru2spaces/windowcredit2spaces TotalNo.ofRequiredParkingSpaces 138 TotalNo.ofCreditParkingSpaces 2 No.ofProvidedParkingSpaces 141 TotalNo.ofParkingSpaces(includescredit)143 (Note:143parkingspacesareshownontheproposedsiteplan.Byordinance,compactand tandemspacescannotbecountedtowardsmeetingminimumparkingrequirements.For SPR220076Page|5of13 commercialdevelopmentcontainingamultitenantpad,anychangeinusewhere50percentor moreofthepadrequiresadditionalparkingpursuanttoBakersfieldMunicipalSection17.58.110, thePlanningDirectormayrequireparkingcommensuratewiththenewuse.) !tt\[L/!b{RESPONSE:__________________________________________________________ 2.Minimumparkingstalldimensionsshallbe9feet wideby18feetlongandshallbedesigned accordingtostandardsestablishedbytheTrafficEngineer.Vehiclesmayhangoverlandscape areasnomorethan21/2feetprovidedrequiredsetbacksalongstreetfrontagesaremaintained, andtreesandshrubsareprotectedfromvehicles. !tt\[L/!b{RESPONSE:__________________________________________________________ 3.Allparkinglots,driveways,driveaisles,loadingareas,andothervehicularaccessways,shallbe pavedwithconcrete,asphalticconcrete,orotherpavedstreetsurfacingmaterialinaccordance withtheBakersfieldMunicipalCode(Sections15.76.020and17.58.060.A.). !tt\[L/!b{RESPONSE:__________________________________________________________ 4.Lightingisrequiredforallparkinglots,exceptresidentiallotswithfourunitsorless(Section 17.58.060.A.).Illuminationshallbeevenlydistributedacrosstheparkingareawithlightfixtures designedandarrangedsothatlightisdirecteddownwardandisreflectedawayfromadjacent propertiesandstreets.Useofglareshieldsorbafflesmayberequiredforglarereductionor controlofbacklight.Nolightpoles,standardsandfixtures,includingbasesorpedestals,shall exceedaheightof40feetabovegrade.However,lightstandardsplacedlessthan50feetfrom residentiallyzonedordesignatedproperty,orfromexistingresidentialdevelopment,shallnot exceedaheightof15feet.Thefinalbuildingplansshallincludeapictureordiagramofthelight fixturesbeingusedandshowhowlightwillbedirectedontotheparkingarea. (Note:Staffcanrequireadditionaladjustmentstoinstalledlightingafteroccupancytoresolve glareorotherlightingproblemsiftheynegativelyaffectadjacentproperties.) !tt\[L/!b{RESPONSE:__________________________________________________________ 5.Becauseparkingand/oraccessisbeingsharedwithadjacentproperties,thedevelopershallfile withthePlanningDivisionbeforeanybuildingpermitsareissuedacopyofarecordedmap, CC&Rs,orotherinstrumentthatensuresthatdriveaisles,parking,andaccessislegallysharedin commonwithadjoiningpropertiesasdepictedonthesiteplanforthelifeoftheproject. !tt\[L/!b{RESPONSE:__________________________________________________________ 6.Thedevelopershallincludeafinallandscapeplanwitheachsetofthebuildingplanssubmittedto theBuildingDivision.BuildingpermitswillnotbeissueduntilthePlanningDivisionhasapproved thefinallandscapeplanforconsistencywithapprovedsiteplansandminimumordinance standards.PleaserefertothelandscapingrequirementsinChapter17.61.Landscapeplansshall include,butarenotlimitedto,dataon:gallon/boxsize,spacing,species(referenceapproved parkinglottreelist),ratioofdeciduousvs.evergreen,shadecalculations,groundcover calculations,etc. SPR220076Page|6of13 (Note1:Atthetimeafinalsiteinspectionisconducted,itisexpectedthatplantswillmatchthe speciesidentifiedandbeinstalledinthelocationsconsistentwiththeapprovedlandscapeplan. ChangesmadewithoutpriorapprovalofthePlanningstaffmayresultintheremovaland/or relocationof installedplantmaterialsanddelaysinobtainingbuildingoccupancy.) (Note2:NomaturelandscapingshallberemovedwithoutpriorapprovalbythePlanning Director.) a. Uponapprovalofthefinallandscapeplan,adigitalcopyshallbesubmittedtothePlanning staffcontactlistedabove.) !tt\[L/!b{RESPONSE:__________________________________________________________ 7.Streetaddressesfortheprojectshallbedesignatedbystaff.Thesenumberswillbetheonly addressesassignedbythecityunlessyouwishtohaveadifferentaddressprogram.Internal buildingunitaddresseswillbeonlybysuitenumberandwillbetheresponsibilityoftheowneror developertoassigntoeachtenant.PleasecontactPlanningDivisionat6613263733forfurther information. (Note:Itisrecommendedthatyouassignsuitenumbersbeginningwith100,200,300etc.instead ofanalphabeticcharacter.Ifinthefutureatenantspaceweresplit,youwouldthenbeableto assignasuitenumberbetweentheexistingnumbers,whichwouldkeepyoursuitesinnumerical order.Keepinganorderlynumberingsystemwillmakeiteasierforcustomers,emergency personnel,andmaildeliverytofindthebusiness.) !tt\[L/!b{RESPONSE:__________________________________________________________ 8.Businessidentificationsignsare neitherconsiderednorapproved underthisreview(e.g.,wall, monument,pylon,etc.).AseparatesignpermitreviewedbythePlanningandBuildingDivisions andissuedbytheBuildingDivision,isrequiredforallnewsigns,includingfutureuseand constructionsigns. (Note:SignsmustcomplywiththeSignOrdinance;Chapter17.60oftheBakersfieldMunicipal Code.ReviewthisChapteraspartofduediligence.) !tt\[L/!b{RESPONSE:__________________________________________________________ 9.Storageofmaterialsandmerchandiseisprohibitedunlessscreenedinaccordancewiththe municipalcode.Salesofmerchandiseshallnotbepermittedinanyrequiredparkingarea.Sales ofmerchandiseshallbeconductedand/orcontainedwithinanenclosedbuildingorwithina screenedareadedicatedforsuchuse. (Note:Thisdoesnotincludeoutdoorseatingareasforrestaurants.) !tt\[L/!b{RESPONSE:__________________________________________________________ SPR220076Page|7of13 10.Refusecollectionbinenclosuresandcontainerareasaresubjecttoallrequiredstructuralsetback fromstreetfrontages,andshallnotreduceanyparking,loadingorlandscapingareasasrequired bytheZoningOrdinance. !tt\[L/!b{RESPONSE:__________________________________________________________ 11.ThedevelopershallmeetallregulationsoftheSanJoaquinValleyAirPollution ControlDistrict (RegulationVIII)concerningdustsuppressionduringconstructionoftheproject.Methods include,butarenotlimitedto;useofwaterorchemicalstabilizer/suppressantstocontroldust emissionfromdisturbedarea,stockpiles,andaccessways;coveringorwettingmaterialsthatare transportedoffsite;limitconstructionrelatedspeedto15mphonallunpavedareas/washingof constructionvehiclesbeforetheyenterpublicstreetstominimizecarryout/trackout;andcease gradingandearthmovingduringperiodsofhighwinds(20mphormore). !tt\[L/!b{RESPONSE:__________________________________________________________ 12.Priortoreceivingfinalbuildingorsiteoccupancy,youmustcontactthePlanningDivision(staff contactnotedabove)forfinalinspectionandapprovalofthelandscaping,parkinglot,lightingand otherrelatedsiteimprovements.Inspectionswillnotbeconducteduntilallrequireditemshave beeninstalled.AnydeviationsfromtheapprovedplanswithoutpriorapprovalfromthePlanning Divisionmayresultinreconstructionanddelaysinobtainingabuildingorsiteoccupancy. !tt\[L/!b{RESPONSE:__________________________________________________________ C.FIREDEPARTMENT(2101HStreet) (StaffcontactErnieMedina;6613263682orEMedina@bakersfieldfire.us) 1.Showonthefinalbuildingplansthefollowingitems: a.Allfirehydrants,bothoffsite(nearesttosite)andonsite.Includeflowdata ƚƓğƌƌ ŷǤķƩğƓƷƭ͵Hydrantsshallbeingoodworkingconditionandaresubjecttotestingfor verification.Fireflowrequirementsmustbemetpriortoconstructioncommencingon theprojectsite.Pleaseprovidetwo(2)setsofthewaterplansstampedbyalicensed RegisteredCivilEngineertotheFireDepartmentandtwo(2)setstotheWaterResources Department(1000BuenaVistaRoad,Bakersfield,CA.93311;6613263715). i. Showdistancetothenearesthydrant. ii. Showdistancefromthenearesthydranttothefarthestpointoftheprojectsite. b.Allfiresprinklerand/orstandpipesystems,firealarmsandcommercialhoodsystems. ThesesuppressionsystemsrequirereviewandpermitsbytheFireDepartment.TheFire Departmentwillissueguidelinesforthesevariousitemsastheymayapplytothisproject. !tt\[L/!b{RESPONSE:__________________________________________________________ SPR220076Page|8of13 2.TurningRadius:Theminimumturningradiusshallbethirtysevenfeet(showfireaccessonthe plans). !tt\[L/!b{RESPONSE:__________________________________________________________ 3.Ifyouhandlehazardousmaterialsorhazardouswasteonthesite,thePreventionServicesDivision mayrequireahazardousmaterialmanagementand/orriskmanagementplanbeforeyoucan beginoperations.Pleasecontactthemat6613263979forfurtherinformation. !tt\[L/!b{RESPONSE:__________________________________________________________ 4.Ifyoustorehazardousmaterialsonthesiteineitheranundergroundorapermanent abovegroundstoragetank,apermitfromthePreventionServicesDivisionisrequiredtoinstall andoperatethesetanks.ThePreventionServicesDivisionmayalsorequireaSpillPrevention ControlandCountermeasurePlanforstorageofpetroleumproductsabovegroundinquantities of1,320gallonsormore.Pleasecontactthemat6613263979forfurtherinformation. !tt\[L/!b{RESPONSE:__________________________________________________________ 5.AllprojectsmustcomplywiththecurrentCaliforniaFireCodeandcurrentCityofBakersfield MunicipalCode(includeoccupantload). !tt\[L/!b{RESPONSE:__________________________________________________________ D.WATERRESOURCES(1000BuenaVistaRoad) (StaffcontactΑTylorHester;6613263009orTHester@bakersfieldcity.us) 1.Developershallsubmittwo(2)setsofutilityplanssignedbyaCaliforniaRegisteredCivilEngineer totheWaterResourcesDepartmentshowingalloffsiteandonsiteimprovements,including connectionstotheexistingwatermainandundergroundfirewaterlinesandrelatedapparatuses. Includeanyexistingnearbyonoroffsitehydrantsontheplans.Plansshallbesubmittedalong withapplicableplancheckfeesandanyotherassociatedfeesperthecurrentfeeschedule.Plans shallcomplywithcurrentCityStandardsandSpecifications,CaliforniaFireCode,andCityof BakersfieldMunicipalCode.CityStandardsandSpecificationsandthecurrentFeeScheduleare availablefordownloadfromthe/źƷǤƭwebsiteat www.bakersfieldcity.us/gov/depts/water_resources/fees.htm !tt\[L/!b{RESPONSE:__________________________________________________________ 2.DevelopershallpaytherequiredWaterResourcesFireServiceInspectionFeesandsubmitan LƓƭƦĻĭƷźƚƓwĻƨǒĻƭƷCƚƩƒ foranyundergroundfirewaterlinesandtheirapparatusesatleasttwo (2)fullbusinessdaysbeforepermanentconstruction.Theformisavailablefordownloadfrom the/źƷǤƭwebsiteatwww.bakersfieldcity.us/gov/depts/water_resources/fees.htm !tt\[L/!b{RESPONSE:__________________________________________________________ SPR220076Page|9of13 E.PUBLICWORKSENGINEERING(1501TruxtunAvenue) (StaffcontactΑSusannaKormendi;6613263997orskormendi@bakersfieldcity.us) 1.Showonthefinalbuildingplansallexistingconnection(s)tothepublicsewersystem. !tt\[L/!b{RESPONSE:__________________________________________________________ 2.IfagradingplanisrequiredbytheBuildingDivision,buildingpermitswillnotbeissueduntilthe gradingplanisapprovedby both thePublicWorksDepartmentandtheBuildingDivision. !tt\[L/!b{RESPONSE:__________________________________________________________ 3.Allstormwatergeneratedontheprojectsite,includingthestreetfrontageshallberetainedonsite unlessotherwiseallowedbythePublicWorksDepartment(pleasecontactthePublicWorks DepartmentΑSubdivisionsat6613263576). !tt\[L/!b{RESPONSE:__________________________________________________________ 4.Iftheprojectgeneratesindustrialwaste,itshallbesubjecttotherequirementsoftheIndustrial WasteOrdinance.AnindustrialwastepermitmustbeobtainedfromthePublicWorks Departmentbeforeissuanceofthebuildingpermit.Tofindoutwhattypeofwasteisconsidered industrial,pleasecontacttheWastewaterTreatmentSuperintendentat6613263249. !tt\[L/!b{RESPONSE:__________________________________________________________ 5.Priortosubmittingrevisedplans,pleasecontacttheConstructionSuperintendentat661326 3049toscheduleasiteinspectiontofindoutwhatimprovementsmayberequired.Beforeany buildingorsitecanbeoccupied,thedevelopermustreconstructorrepairsubstandardoffsite streetimprovementsthatfrontthesitetoadoptedcitystandardsasdirectedbytheCityEngineer. Additionally,anyoffsite/frontageimprovementsorrepairsrequiredduringthesiteinspection shallbeshownonthegradingplanorfinalbuildingplan. !tt\[L/!b{RESPONSE:__________________________________________________________ 6.AstreetpermitfromthePublicWorksDepartmentshallbeobtainedbeforeanyworkcanbedone withinthepublicrightofway(streets,alleys,easements).Pleaseincludeacopyofthissiteplan reviewdecisiontothedepartmentatthetimeyouapplyforthispermit. !tt\[L/!b{RESPONSE:__________________________________________________________ 7.Asewerconnectionfeeshallbepaidatthetimeabuildingpermitisissued.Wewillbasethisfee attherateineffectatthetimeabuildingpermitisissued. !tt\[L/!b{RESPONSE:__________________________________________________________ SPR220076Page|10of13 8.IftheprojectissubjecttotheprovisionsoftheNationalPollutantDischargeEliminationSystem (NPDES),aͻbƚƷźĭĻofLƓƷĻƓƷͼ(NOI)tocomplywiththetermsoftheGeneralPermittoDischarge StormWaterAssociatedwithConstructionActivity(SWRCBOrderNo.2009009DWQas amendedbyOrderNo.2010 0014DWQand20120006DWQ)mustbefiledwiththeStateWater ResourcesControlBoardinSacramentobeforethebeginningofanyconstructionactivity. CompliancewiththegeneralpermitrequiredthataStormWaterPollutionPreventionPlan (SWPPP)beprepared,continuouslycarriedout,andalwaysbeavailableforpublic inspection duringnormalconstructionhours. !tt\[L/!b{RESPONSE:__________________________________________________________ 9.Priortotheissuanceofeachbuildingpermit,orifnobuildingpermitisrequired,thefirstrequired Cityapprovalpriortoconstruction,thedeveloper/ownershallpayaTransportationImpactFee (TIF)forregionalfacilities.Thisfeewillbebasedontherateineffectatthetimetheapplicable approvalisissuedorinaccordancewiththeSubdivisionMapAct,asapplicable.ThePublicWorks Departmentwillcalculateanestimateofthetotalfeeuponsubmittalofconstructionplansfor theproject. !tt\[L/!b{RESPONSE:__________________________________________________________ 10.ThedevelopershallformanewMaintenanceDistrict.Undevelopedparcelswithinanexisting MaintenanceDistrictarerequiredtoupdateMaintenanceDistrictdocuments.Updated documents,includingProposition218BallotandCovenant,shallbesignedandnotarized.Ifthere arequestions,contactSubdivisionsat6613263588. (Note:Ifalreadywithinamaintenancedistrict,mayneedtoupdatethemaintenancedistrict form.) !tt\[L/!b{RESPONSE:__________________________________________________________ 11.Thedevelopershallinstallafullsizedmanholeineachsewerlineexceptresidentialdevelopment beforeitconnectstothesewermain.Thismanholeistobelocatedwithinthepropertybeing developedandmustbeeasilyaccessiblebyCityworkers. !tt\[L/!b{RESPONSE:__________________________________________________________ F.PUBLICWORKSTRAFFIC(1501TruxtunAvenue) (StaffcontactΑSusannaKormendi;6613263997orskormendi@bakersfieldcity.us) 1.ShowonthefinalbuildingplansstandardST4driveapproach(es).Driveapproachesmustbe centeredondriveaisles.Alldimensionsshallbeshownonthefinalbuildingplans. !tt\[L/!b{RESPONSE:__________________________________________________________ 2.Ifapplicable,thedevelopershalldedicateanysidewalkextendingoutoftherightofwaytothe CityofBakersfieldforthepedestrianwayalongallarterialstreets.Thismustbeconductedwith aseparateinstrumentorfinalmap. !tt\[L/!b{RESPONSE:__________________________________________________________ SPR220076Page|11of13 G.PUBLICWORKSSOLIDWASTE(4101TruxtunAvenue) (StaffContactRichardGutierrez:rmgutierrez@bakersfieldcity.us) 1.Youmustcontactthestaffpersonnotedabovebeforebuildingpermitscanbeissuedorwork beginsonthepropertytoestablishthelevelandtypeofservicenecessaryforthecollectionof refuseand/orrecycledmaterials.Collectionlocationsmustprovideenoughcontainmentarea for therefusethatisgeneratedwithoutviolatingrequiredzoningorsetbackrestrictions(seePlanning Divisionconditions).Levelsofservicearebasedonhowoftencollectionoccursasfollows: Cartservice1cubicyard/weekorless1timeperweek Frontloaderbinservices1cubicyard/week12cubicyards/day RolloffcompactorserviceMorethan12cubicyards/day !tt\[L/!b{RESPONSE:__________________________________________________________ 2.Showonthefinalbuildingplansrefuse/recyclebinenclosures.Eachenclosureshallbedesigned accordingtoadoptedcitystandard(Detail#ST27andST28),atthesizecheckedbelow. Beforeoccupancyofthebuildingorsiteisallowed,3,3cubicyardfrontloadingtype refuse/recyclebin(s)shallbeplacedwithintherequiredenclosure(s). 8'deepx15'wide(3bins) 8'deepx20'wide(4bins) 8'deepx10'wide;onskidsfordirectstabonly(16yardrecyclingbin) (Note:Allmeasurementsabovearecurbtocurbdimensionsinsidetheenclosure.Ifbothrefuse andrecyclingcontainersaretobecombinedinthesameenclosurearea,thisareamustbe expandedinsizetoaccommodatemultiplecontainers/binscontactthestaffpersonabovefor theappropriateenclosuresize.) !tt\[L/!b{RESPONSE:__________________________________________________________ 3.Examplesofenclosurestylescanbefoundon(Detail#ST27ST29B). !tt\[L/!b{RESPONSE:__________________________________________________________ 4.Facilitiesthatrequireinfectiouswasteservicesshallobtainapprovalforseparateinfectiouswaste storageareasfromtheKernCountyHealthDepartment.Innoinstancesshalltherefusebinarea beusedforinfectiouswastecontainmentpurposes. !tt\[L/!b{RESPONSE:__________________________________________________________ 5.Facilitiesthatrequiregreasecontainmentmustprovideastoragelocationthatisseparatefrom therefusebinlocation.Thisshallbeshownonthefinalbuildingplans.Ifagreaseinterceptoris tobeusedinsteadofagreasecontainmentbin,theplansmuststillshowthelocationofan adequatelysizedenclosureshouldagreasecontainmentbinberequiredatafuturedate.The greasecontainmentbinshallnotsharethesameenclosureastherefuse/recyclable/organicbin enclosure. SPR220076Page|12of13 !tt\[L/!b{RESPONSE:__________________________________________________________ 6.Facilitieswithexistingrefuseservicemustimprovetheservicelocationarea(s)accordingto adoptedCitystandards(Detail#ST27andST29B).Theseimprovementsshallbeclearlyshown onthefinalbuildingplans. !tt\[L/!b{RESPONSE:__________________________________________________________ 7.Ifutilitiesareincorporatedintotheenclosuredesign,theyshallnotinterferewithspaceprovided forrefusebinsandmustprovidesufficientprotectionmeasurestoguardtheutilitiesfrom damage. !tt\[L/!b{RESPONSE:__________________________________________________________ 8.Enclosuresshallnotbelocatedinanareathatwouldcauserefusetruckstointerferewithdrive thrutrafficflowenteringorexitingthesite,drivethrulanes,etc. !tt\[L/!b{RESPONSE:__________________________________________________________ 9.Businessesarerequiredtohavesufficientcapacityofrefuse/recycling/organicmaterialstorageto gowithoutservicefor1day(Sunday).Atanytime,refuse/recycling/organicservicesbecomean issue,businessesshallconstructasecondrefuseenclosuretomeetthedemand.Thesecond enclosureshallbeapprovedbytheCitypriortoconstruction. !tt\[L/!b{RESPONSE:__________________________________________________________ 10.Revisethesiteplantomakethetrashenclosureaccessibletotherefusetruck.Citytrucksmay notdrivedowndeadendcorridors,norbackuplongdistances;therefore,aturnaroundarea shallbeprovided. !tt\[L/!b{RESPONSE:__________________________________________________________ SPR220076Page|13of13 8 143